GSW30Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating
|
|
- Hope Parker
- 7 years ago
- Views:
Transcription
1 Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw Ratings definition (According to standard ISO8528 1:2005) PRP - Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power. LTP - Limited-Time running Power: It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.
2 Engine Specifications Brand Model Version Exhaust emission level Exhaust emission optimized for EPA tier 60Hz (EPA) Engine cooling system Nr. of cylinder and disposition Yanmar 4TNV98-GPGE 50 Hz Stage II Tier II Water 4 in line Displacement cm³ 3319 Aspiration Speed governor Natural Mechanical Operating Speed-Nominal rpm 1500 Prime gross power PRP kw 31.2 Maximum gross power LTP kw 34.6 Oil capacity L 10.5 Coolant capacity L 4.2 Fuel Specific fuel 75% PRP g/ kwh Specific fuel PRP g/ kwh Starting system Diesel Electric Starting engine capability kw 1.1 Electric circuit V 12 Fuel 75% PRP L/h 5.82 Fuel 100% PRP L/h 7.75 Engine Equipment Standards The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1 Fuel system Direct injection system Fuel filter paper element Fuel pump Bosch in-line Lube oil system Forced feed system Trochoid pump Paper element lube oil filter Induction system Mounted air filter Cooling system Thermostatically-controlled system with gear-driven circulation pump and belt-driven pusher fan Mounted radiator and piping
3 Alternator Specifications Brand Mecc Alte Model ECP28-VL/4 Class H IP protection 23 Poles 4 Frequency Hz 50 Frequency tolerance % 5 Voltage tolerance % 1.5 Power factor cos ϕ % load % 88.5 Standard AVR DSR Mechanical structure Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups. Voltage regulator Voltage regulation with DSR. The digital DSR controls the range of voltage, avoiding any possible trouble that can be made by unskilled personnel. The voltage accuracy is ±1% in static condition with any power factor and with speed variation between 5% and +30% with reference to the rated speed. Windings / Excitation system Generator stator is wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for troublefree supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. MAUX (Standard): The MAUX MeccAlte Auxiliary Winding is a separate winding within the main stators that feeds the regulator. This winding enables to take an overload of 300% forced current (short circuit maintenance) for 20 seconds. This is ideal for motor starting requirements. PMAUX (optional): Alternator can be equipped with the optional PMAUX (Permanent Magnet Generator) which matches the performance and is capable of supporting both linear and distorted loads. Insulation / Impregnation Insulation is of class H standard. Impregnation is made with premium tropicalised epoxy resins by dipping and dripping. High voltage parts are impregnated by vacuum, so the insulation level is always very good. In the high-power models, the stator windings undergo a second insulation process. Grey protection is applied on the main and exciter stator to give enhanced protection. Reference standards Alternator manufactured according to, and complies with, the most common specification such as CEI 2-3, IEC 34-1, EN , VDE 0530, BS , CAN/ CSA-C22.2 No14-95-No
4 Genset equipment BASE FRAME MADE OF WELDED STEEL PROFILE, COMPLETE WITH: Anti-vibration mountings properly sized Welded support legs PLASTIC FUEL TANK WITH THE FOLLOWING COMPONENT: Filler neck Air breather (ventilation pipe) Minimum fuel level sensor OIL DRAININ PIPE WITH CAP: Oil draining facilities ENGINE COMPLETE WITH: Battery Liquids (no fuel) CANOPY: Soundproof canopy made up of modular panels, realized with zinced steel as treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a full weatherproof enclosure. Easy access to the genset for maintenance purposes thanks to: Wide lateral access doors fixed by stainless steel hinges and provided with plastic lockable handles and internal perforated galvanized steel-sheet; Detachable panels, with screws holes protected by rubber tap. Control panel protection door provided with suitable window and lockable handle. Lateral air inlet opening properly protected and soundproofed. Exhaust air outlet from the roof, trough wet section protected by proper grid. Single detachable lifting eye placed on the roof. SOUNDPROOF: Noise attenuation thanks to soundproofing material (rock wool) Efficient residential silencer placed inside the canopy
5 Dimensional data Length (L) mm 2005 Width (W) mm 948 Height (H) mm 1308 Dry weight kg 773 Fuel tank capacity L 68 Autonomy Running 75% PRP h Running 100% PRP h 8.77 Noise level Guaranteed noise level (LWA) db(a) 95 Noise pressure 7 mt db(a) 66 Data Current Battery capacity Ah 70 MAX current A Circuit breaker A 50 Control panel availability MANUAL CONTROL PANEL MCP MANUAL CONTROL PANEL FULL OPTION MPF AUTOMATIC CONTROL PANEL ACP
6 MCP - Manual control panel Mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set, protected through door with lockable handle. INSTRUMENTATION (ANALOGUE) Voltmeter (1 phase) Ammeter (1 phase) Hours-counter COMMANDS Start/stop selector switch with key (Glow plugs preheating function also included). Emergency stop button installed on canopy side. PROTECTION WITH ALARM Low fuel level Battery charger failure low oil pressure high engine temperature Earth Fault. PROTECTIONS WITH SHUTDOWN Low fuel level Battery charger failure low oil pressure high engine temperature. Circuit breaker protection: III poles Emergency stop button OTHERS Panel protected through door with lockable handle. OUT PUT PANEL MCP Power cables connection to Circuit Breaker. Socket kit Standard Thermal protections 3P+N+T 400V 63A n 1 3P+N+T CEE 400V 32A n 1 2P+T CEE 230V 16A n 2 230V 16A SCHUKO n 1
7 MPF - Manual control panel full option Mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set, protected through door with lockable handle INSTRUMENTATION (ANALOGUE) Voltmeter with selector switch (3 phases) Frequency meter Ammeter with selector switch (3 phases) Hours-counter Fuel level indicator Oil pressure indicator Engine temperature indicator COMMANDS Start/stop selector switch with key Emergency stop button PROTECTION WITH ALARM Low fuel level Battery charger failure low oil pressure high engine temperature Earth Fault PROTECTIONS WITH SHUTDOWN Low fuel level Battery charger failure low oil pressure high engine temperature Circuit breaker protection: III poles Emergency stop button OTHERS PROTECTIONS Panel protected through door with lockable handle OUT PUT PANEL MPF ETB- External Terminal Board ETB Socket kit Standard Individual CB and Earth Fault protection 400V/63A 3P+N+T CEE n 1 400V/32A 3P+N+T CEE n 1 400V/16A 3P+N+T CEE n 1 230V/16A 2P+T CEE n 1 230V/16A SCHUKO n 1
8 ACP - Automatic control panel Mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set, protected through door with lockable handle. DIGITAL INSTRUMENTATION (through AC-03) Generating set voltage (3 phases). Mains voltage. Generating set frequency. Generating set current (3 phases). Battery voltage. Power (kva - kw - kvar). Power factor Cos φ. Hours-counter. Engine speed r.p.m. Fuel level (%). Engine temperature (depending on model) COMMANDS AND OTHERS Four operation modes: OFF - Manual starting - Automatic starting - Automatic test. Pushbutton for forcing Mains contactor or Genset contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Remote starting availability. DC system disconnection switch. Acoustic alarm. Automatic battery charger. RS232 Communication port. Settable PASSWORD for protection level. PROTECTIONS WITH ALARM Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage PROTECTIONS WITH SHUTDOWN Engine protections: low fuel level, low oil pressure, high engine temperature, Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Circuit breaker protection: III poles. Earth Fault included in the control unit. OTHERS PROTECTIONS Emergency stop button. Panel protected through door with lockable handle. OUT PUT PANEL ACP Plinth row for connection from ACP to LTS panel. 3P+N+T CEE 400V 63A n 1 Predisposed for remote control optional: RCG Socket kit Optional
9 Supplements: Only Available when order : CONTROL PANEL SUPPLEMENT RCG - Various supplements for remote controls - available for models: TLP - Various supplements for remote signals - available for models: ADI - Adjustable Differential Intensity - available only for models: TIF - IV Poles Circuit Breaker instead of III - available for models: ETB - External Terminal Board - available for models: ACP ACP ACP ACP MCP MCP ACP Socket kit SKB socket kit B - available for models: ACP MCP Individual CB and Earth Fault protection 400V/63A 3P+N+T CEE n 1 400V/32A 3P+N+T CEE n 1 400V/16A 3P+N+T CEE n 1 230V/16A 2P+T CEE n 1 230V/16A SCHUKO n 1 NB: for assembly is necessary: ETB GENSET EQUIPMENT KPR - Premium Kit (Leak Proof Tray - Leakage detection sensor - Manual oil drain pump) AFP - Automatic Fuel Pump - available for models: KRT - Kit Rental which includes fuel filter with water separator, 3- way fuel valve, battery switch, earth rod, docs folder) ACP Extended Fuel Tank Fuel tank capacity L 450 Length (Genset) (L) mm 2005 Width (Genset) (W) mm 1066 Height (Genset) (H) mm 1812 ENGINE SUPPLEMENTS PHS - Coolant Pre-Heating System - available for models: ACP
10 Accessories Items available as accessory equipment STR - Site trailer RTR - Road Trailer LTS - LOAD TRANSFER SWITCH - Accessories ACP The Load Transfer Switch (LTS) panel operates the power supply changeover between the generator and the Mains in backup applications, guarantying the feeding to the load within a short period of time. It consists of a standalone cabinet which can be installed separate from the generating set. The logic control of the power supply changeover is operated by means of the Automatic Control panel mounted on the generating set, so therefore none logic device is required on the LTS panel. NOMINAL CURRENT & DIMENSIONS PANEL LTS (standard*) Nominal Current A 60 Width (W) mm 400 Height (H) mm 400 Depth (D) mm 240 Weight kg 14 * = Available electrical power more Publishing date: 29/04/ PR INDUSTRIAL s.r.l. All rights reserved Image shown may not reflect actual package. Specifications subject to change without notice ENERGY GENERATION is registered trademarks of PR INDUSTRIAL s.r.l. Other company, product or service names may be trademarks or service marks of others. RevA (06/2012).
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
More informationDLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw
DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw
,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted
More informationPower kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1
K3 WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor
More informationPower kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8
SILENT PACK AIR-COOLED SINGLE PHASE 60 HZ INT. TIER IV DIESEL Generating Rates SERVICE PRP STANDBY Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power
More informationDiesel Generating Set
MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationAtlas Copco Generators
Atlas Copco Generators QIX 15 - QIX 540 16 kva LTP to 549 kva LTP at 50 & 60 Hz The QIX options include Earth leakage relay Qc generating set control panels for all standby and/or paralleling applications
More informationAnnex-A TECHNICAL SPECIFICATION
Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery
More informationHFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO
D10 WATER-COOLED THREE PHASE 50 HZ STAGE 2 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 100 107 Power kw 79 86 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 230-230/132
More informationSpark-ignited generator set
Specification sheet Spark-ignited generator set 30 60 kw standby EPA emissions Description Cummins Power Generation commercial generator sets are fully integrated power generation systems providing optimum
More informationPower kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1
E10 (HIGH SPEED) WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at
More informationMagnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
More informationDIESEL GENERATOR SETS
DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete
More informationTECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 50HZ MP Series MPS180S 1 / MPS180 1 MPS180S 1 / MPS180 1 MP Series Features Compact structure with high strength chassis; Easy operation and maintenance,
More informationDIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET
DIESEL SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are Tier II EPA
More informationThe 26 200 kva RAnge
The 26 200 kva Range The new 26 200 kva range...designed to Deliver More. We understand the unique needs of generating set customers around the world. Forty years experience combined with the latest technology
More informationMarine Generating Sets 3.7 to 50 kva
Marine Generating Sets 3.7 to 50 kva The Marine Engineer s Preference BetaSet - Standard Marine Generators Beta Marine has considerable experience from over twenty years of manufacturing marine generating
More informationGEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer
D I E S E L G E N E R A T O R S E T GEP550 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET Complete system designed and built at ISO9001 certified facility Factory
More informationXQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)
RENTAL Standby Prime Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) Shown with optional trailer FEATURES EPA TIER 4 AND CARB CERTIFIED
More informationREVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
More information4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm
The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance
More informationAPS100 Rental Generator Set Specification
BARTONVIE * CEDAR RAPIDS * DAVENPORT * EAST PEORIA * HANNIBA * MOBERY * ROCK FAS * SPRINGFIED * URBANA APS100 Rental Generator Set Specification STANDBY 100 kw 60 Hz/PRIME 90 kw 60 Hz FEATURES EPA TIER
More informationTECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 60HZ MC Series MCS600S-2 / MCS600-2 MCS600S-2/ MCS600-2 MC Series Features Reference images, the actual shall prevail Compact structure with high-strength
More informationPower Generation. Power Control PCL System Generator Set Control
Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationPM734F - Technical Data Sheet Winding 28
- Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationPI734D - Technical Data Sheet
PI734D - Technical Data Sheet PI734D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
More informationPI734B - Technical Data Sheet
PI734B - Technical Data Sheet PI734B SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
More informationGEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer
D I E S E L G E N E R A T I N G S E T GEP150 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 150 kva / 120 kw 135 kva / 108 kw 165 kva / 132 kw 150 kva / 120 kw FEATURES GENERATING SET Complete system
More informationTechnical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
More informationPI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
PI044E - Winding 311 Technical Data Sheet PI044E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationCooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
More informationPI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS
PI144K - Winding 311 Technical Data Sheet PI144K SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section
More informationUCI274C - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,
More informationUCI274H - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationCUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4006-23TAG3A diesel engine Stamford HCI 634 H alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty
More informationCUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4006-23TAG2A diesel engine Newage/Stamford HCI634G alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
More information3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm
Marine Auxiliary Engine SPECIFICATIONS 3304B 56 bkw (75 bhp) 100 mhp @ 1200 rpm Shown with Accessory Equipment I-4, 4-Stroke-Cycle-Diesel Emissions...IMO compliant Displacement... 7.0 L (425 cu. in.) Bore...
More informationCAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw
CAT NEXT GENERATION DIESEL GENERATOR SETS C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw THE NEXT GENERATION CAT DIESEL GENERATOR SET FEATURES SEVERAL KEY DESIGN AND PERFORMANCE ENHANCEMENTS TO ITS
More informationVisions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
More informationBCI184E - Technical Data Sheet
BCI184E - Technical Data Sheet BCI184E SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
More informationAUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
More informationCoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
More informationPhotovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationSTANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered
More informationSTANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered
More informationHybrid GenSet HYBRID POWER UNIT. Hybrid GenSet. POWER RANGE 7-35 kw. APPLICATIONS Outdoor Indoor Telecom Site. www.ascotinternational.
EN POWER RANGE 7-35 kw APPLICATIONS Outdoor Indoor Telecom Site 1 Desert Border Control (Middle East) Remote Off Grid Indoor TLC Site (Africa) Remote Off Grid OutdoorTLC Site (Asia) Remote Off Grid Indoor
More informationHYBRID POWER SYSTEMS for TELECOM applications
HYBRID POWER SYSTEMS HYBRID POWER SYSTEMS HYBRID POWER SYSTEM WITH AC GENSET PRAMAC has developed a new solution that allow coupling a traditional AC constant speed diesel genset with an energy storage
More informationTechnical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationSTANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts
DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
More informationSTANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts
DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 800 ekw 1000kVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,
More informationA Single Source for all Power System Solutions
Power Generation Gas Engine Powered Generating Sets 1540-1750 kwe 50 Hz 1250-1760 kwe 60 Hz QSV91G Series Engines Standard Genset Features Single Source Responsibility Design, manufacture and testing of
More informationRENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES
XQ230 SOUND ATTENUATED DUAL VOLTAGE 50/60 Hz Arrangement shown with optional trailer FEATURES EMISSIONS EPA Tier 3 and CARB Emissions Certified for non-road mobile applications at all 60 Hz and 50 Hz ratings
More information30-120 3 Phase Modular Finally the benefits of Modular ups are for all
MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion
More informationTMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
More informationAGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ
Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Standard Features 3 Cylinder Diesel Engine for maximum durability, reliability and efficiency. Brushless alternator
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationRental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES
C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES Factory designed, certified prototype tested with torsional analysis. Production tested and delivered in a package that is ready
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationIGSA POWER GENERATION SYSTEMS
IGSA POWER GENERATION SYSTEMS MODEL: GSDD20600S. MTU, 12V1600G80S, 1800 RPM, 60 HZ. CAPACITY KW KVA 600 750 Reference Conditions ISO 3046: Intake air temperature Side altitude above sea level Charge air
More informationHCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
HCM434F - Winding 311 Technical Data Sheet HCM434F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards
More informationDIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption
IE DIESEL FEATURES GENERATOR SET PRIME 2000 ekw 2500 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability,
More informationHow To Control A Power Command Powerplant
Diesel Generator Set Model DFEJ 60 Hz EPA Emissions 450 kw, 563 kva Standby 410 kw, 513 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power
More informationGenerators TEM. for small hydroelectric power stations. Electric Machines
Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric
More informationRotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
More informationElectric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
More informationConlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
More informationSTANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts
DIESEL GENERATOR SET STANDBY 2500 ekw 3125 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and
More information1100 Series 1104C-44TAG2 Diesel Engine ElectropaK 99.5 kwm @ 1500 rpm
Building upon Perkins proven reputation within the power generation industry, the Perkins 1100 Series range of ElectropaK engines now fit even closer to the needs of their customers. With this 1104C-44TAG2
More informationTitan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.
IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation
More informationCUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4016TAG2A diesel engine Newage/Stamford PI734F alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationINDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT-100 4.9 MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station
D & S Turbine International LLC INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT-100 4.9 MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT-100 4.9 MW /
More informationTechnical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationC18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm
CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationTECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS 15KVA (CANOPY TYPE)
CONTENTS General 1.1 Applications. 3 1.2 Site conditions. 3 1.3 Documentations supplied with offer 4 1.4 Warranty Statements 4 1.5 Training. 5 Diesel Engine specifications 2.1 Cooling System. 6 2.2 Water
More informationCUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4012-46TAG2A diesel engine Newage/Stamford PI734C alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
More informationDiesel Generator Set Model DFHC 60 Hz
Diesel Generator Set Model DFHC 60 Hz 900 kw, 1125 kva Standby 818 kw, 1023 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationCUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
More informationHow To Use A Cat Diesel Engine
DIESEL GENERATOR SET STANDBY 440 ekw 550 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationSpecifications for Volkswagen Industrial Engine
Volkswagen 1 industrial engine Specifications for Volkswagen Industrial Engine AFD 1.9 ltr. TDI diesel engine EURO 2 Volkswagen AG, Wolfsburg Volkswagen AG reserves the right to introduce amendments or
More informationIncubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
More informationDiesel Generator Set Model DFMB 60 Hz
Diesel Generator Set Model DFMB 60 Hz 1500 kw, 1875 kva Standby 1250 kw, 1563 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation
More informationDiesel Generator Set Model DGDK 60 Hz
Diesel Generator Set Model DGDK 60 Hz 125 kw, 156 kva Standby 113 kw, 141 kva Prime Description The Cummins Power Generation DG-series commercial generator set is a fully integrated power generation system
More informationAutomatic Voltage Regulator User s Manual
Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright
More informationData sheet ECC 12 and 22
Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe
More informationExel. 715kVA - 3300kVA 700kWe - 3200kWe
Exel 715kVA - 3300kVA 700kWe - 3200kWe SDMO is recognised as one of the top manufacturers of generating sets in the world. SDMO has channelled all its energy into designing a range which is both highly
More information