MIPI D-PHY Physical Layer Solution. Configuration Guide

Size: px
Start display at page:

Download "MIPI D-PHY Physical Layer Solution. Configuration Guide"

Transcription

1 MIPI D-PHY Physical Layer Solution Configuration Guide

2 Recommended ParBERT MIPI D-PHY configurations There are two MIPI D-PHY configurations available with the ParBERT The main differences between these two configurations are the maximum data rate and jitter injection capabilities: The first of these configurations is the 3.35 GBit/s economic configuration with 500 ps jitter injection capability. The maximum data rate of 3.35 GBit/s limits the usage of Par- BERT modules for other standards and applications. The second ParBERT MIPI D-PHY configuration is the 7 GBit/s multi application setup. As this setup up includes 7GBit/s ParBERT modules it can support a wider range of standards and applications. The table below shows the differences between the two configurations in relation to jitter injection capabilities. Seperate jitter on clock and data lanes 3.35 Gbit/s Economic Solution 7 Gbit/s Multi-application Solution Possible setup suggests clean Possible setup suggests clean clock clock lane and jitter on data lane and jitter on data lanes only lanes only Jitter capabilities 500 ps delay line 200 ps delay line plus jittered ParBERT clock (see below) Externally jittered ParBERT clock Not possible Data rate dependent example at 1 GBit/s Max supported jitter Data 500ps Jittered Clock + 200ps Clock 500ps (capability not used in setup) Jittered Clock + 200ps(capability not used in setup) Agilent MIPI D-PHY Configuration Guide

3 Configuration for the economic D-PHY solution (3.35 Gb/s) Table 1: Configuration for D-PHY solution Signal Generation 4 x 675 MBit/s generators 2 x 3.35 GBit/s generators 250 ps transition time converter 10 ns transition time converter 1 x E4832A with 4 x E4838A 1 x E4861B with 2 x E4862B 1 data lane 2 data lanes 4 data lanes Comments LP signaling and HS offset HS signaling 15432B HS transition time Bitifeye BIT- MIPI-TTC LP transition time, 3rd part product Power splitter 11667B Combine HS and LP signals Set of 4 SMA cables (2 cables Other ParBERT items 8 (2 cables Signal connect Clock module E4808A HS clock Clock module E4805B LP clock ParBERT mainframe 81250A IEEE 1394 PC link to VXI ParBERT software license Laptop including PCMCIA IEEE 1394 card 81250A E4875A Software 81250A PC to operate the setup Power divider 11636B Split LP trigger out to HS and scope Set of 4 SMA cables (1 cable Jitter Generation 81150A with 2 channels BNC to SMA adapter SMA to SMA adapter 81150A, option (1 cable 1 (1 cable Trigger signals Noise generator output adapter Connect power dividers Power divider 11636B Split noise to ParBERT delay lines Set of 4 SMA cables (1 cable 2 (3 cables 3 (2 cables Agilent MIPI D-PHY Configuration Guide

4 Configuration for the economic D-PHY solution (3.35 Gb/s) cont 1 data rate Noise Generation (one lane - use equipment for jitter ) 2 data lanes 4 data lanes Comments Power divider 11636B Re-use power divider for jitter 6 db attenuator 8493C SMA to SMA adapter Re-use adapter for jitter BNC to SMA adapter Re-use adapter for jitter Set of 4 SMA cables Re-use cables for jitter Other 9 GHz or better DSO Scope Options tbd Differential probe 1169A Timing and level measurement with DSO Differential probe head High impedance probe head Control software and test automation 5380A Timing and level measurement with DSO tbd Level measurement with DSO N5990A option tbd Control software LAN hub no Agilent part Remote control instruments LAN cable no Agilent part Remote control instruments Set of 4 SMA cables (2 cables 1 (2 cables 1 (2 cables To connect scope Set of 4 SMA cables Balance unused SMA cables 4 Agilent MIPI D-PHY Configuration Guide

5 Configuration for the multi-application (MIPI and HDMI) solution (7 Gb/s) Table 2: Configuration for multi-application solution Signal Generation 4 x 675 MBit/s generators 1 x E4832A with 4 x E4838A, 1 data lane, 2 data lanes, 4 data lanes Comments LP signaling and HS offset 7 GBit/s generator N4874B HS signaling 250 ps transition time converter 10 ns transition time converter 15432B HS transition time Bitifeye BIT- MIPI-TTC LP transition time, 3rd part product Power splitter 11667B Combine with HS and LP signals Adapter 3.5 mm (f) to 2.4 mm (m) 2.4 mm 50 Ohm termination 3.5 mm 50 Ohm termination N4911A N4912A Terminate unused outputs of 7 G ParBERT Terminate unused outputs of 7 G ParBERT Set of 4 SMA cables (2 cables Other ParBERT Items 8 (2 cables Signal connect Clock module E4809A HS clock Clock module E4805A LS clock ParBERT mainframe 81250A IEEE 1394 PC link to VXI 81250A ParBERT extender mainframe with IEEE1394 link ParBERT software license Laptop including PCM- CIA IEEE 1394 card 81250A E4875A A PC to operate the setup BNC cable Synchronize ESGs Power divider 11636B Clock and triggering ESG Adapter n to 3.5 mm (m) E4438C, options 1E5, 506, Signal generators ESG output to power divider Adapter n to 3.5 mm (f) ESG output to SMA cable SMA to SMA adapter Combine power splitters for triggering Set of 4 SMA cables (1 cable 2 (1 cable 2 (1 cable Agilent MIPI D-PHY Configuration Guide 5

6 Configuration for the multi-application (MIPI and HDMI) solution (7 Gb/s) cont Jitter Generation 81150A with two channels 81150A, option 002, 1 data lane, 2 data lanes, 4 data lanes Comments Noise generator BNC to SMA adapter output adapter SMA to SMA adapter Connect power dividers Power divider 11636B Split noise to ParBERT delay lines Set of 4 SMA cables (1 cable not 2 (2 cables not Noise Generation (one lane - use equipment for jitter ) 3 (2 cables not 1, 2 or 4 needed to distribute noise Power divider 11636B Re-use power divider for jitter 6 db attenuator 8493C SMA to SMA adapter Re-use adapter for jitter BNC to SMA adapter Re-use adapter for jitter Set of SMA cables Re-use cables for jitter Other 9 GHz or better DSO Scope Options tbd Differential probe 1169A Timing and level measurement with DSO Differential probe head High impedance probe head Control software and test automation 5380A Timing and level measurement with DSO tbd Level measurement with DSO N5990A option tbd LAN hub no Agilent part Remote control instruments LAN cable no Agilent part Remote control instruments Set of 4 SMA cables (2 cables not 1 (2 cables not 1 (2 cables not Clock to data skew measurement with DSO Set of 4 SMA cables Balance unused SMA cables 6 Agilent MIPI D-PHY Configuration Guide

7 Figure 1: System configuration diagram for 3.35 Gb/s Figure 2: System configuration diagram for 7 Gb/s Agilent MIPI D-PHY Configuration Guide 7

8 Related Agilent Literature How to characterize the Physical Layer of the Mobile Industry Processor Interface (MIPI D-PHY) Application Note Agilent Updates Get the latest information on the products and applications you select. Agilent Direct Pub.No EN ParBERT E Parallel Bit Error Ratio Tester Product Overview ParBERT 81250, Mux/Demux E application Application Note Productivity Assistance E Advanced Memory Buffer Application Note ParBERT /45 G Product Overview ParBERT G Optics Data Sheet E4887A HDMI TMDS Signal Generator Data Sheet Test Automation Software Platform N5990A Data Sheet For more information, please visit us at EN EN EN EN EN Product specifications and descriptions in this document subject to change without notice. Quickly choose and use your test equipment solutions with confidence. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: Agilent Open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: Phone or Fax United States: Korea: (tel) (tel) (080) (fax) (fax) (080) Canada: Latin America: (tel) (tel) (305) (fax) China: Taiwan: (tel) (tel) (fax) (fax) Europe: Other Asia Pacific (tel) Countries: (tel) (65) Japan: (fax) (65) (tel) (81) tm_ap@agilent.com (fax) (81) Revised: 09/14/06 Agilent Technologies, Inc May 26th EN

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing 81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing Application Note Introduction Industry sectors including computer and components, aerospace defense and education all require

More information

PCI Express 1.0 (2.5 GT/s) Protocol Test

PCI Express 1.0 (2.5 GT/s) Protocol Test PCI Express 1.0 (2.5 GT/s) Protocol Test Configuration and Pricing Guide Gen1 today, ready for Gen2 in the future As PCI Express Gen2 becomes more mature in the market, you must decide whether to continue

More information

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10

More information

Agilent Automotive Power Window Regulator Testing. Application Note

Agilent Automotive Power Window Regulator Testing. Application Note Agilent Automotive Power Window Regulator Testing Application Note Abstract Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters

More information

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems PCI Express for Agilent E2960B PCI Express Analysis Systems Version: 1.2 Superior Signal Probing options to address diverse designs and form factors As an industry leader in the innovation of non-intrusive,

More information

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors Agilent U2000 Series USB Power Sensors Single/Multi-Channel Power Measurement Simple Setup Affordable Demo Guide Table of Contents Introduction 2 The Agilent N1918A Power 3 Analysis Manager Demonstration

More information

Agilent E6832A W-CDMA Calibration Application

Agilent E6832A W-CDMA Calibration Application Agilent E6832A W-CDMA Calibration Application For the E6601A Wireless Communications Test Set Data Sheet The next generation of mobile phone manufacturing test. E6601A is the newest test set from Agilent

More information

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent 8762/3/4A,B,C Coaxial Switches Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.

More information

The Next Generation in Automated Oscilloscope Test

The Next Generation in Automated Oscilloscope Test The Next Generation in Automated Oscilloscope Test Spanning 100 MHz to 13 GHz, and varying in height from 1U to 8U, Agilent s family of LXI compliant oscilloscopes can accommodate virtually any automated

More information

Agilent Television Power Consumption Testing. Application Note

Agilent Television Power Consumption Testing. Application Note Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,

More information

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family Product Overview Requires an Agilent 16700A/B Series or 16900A Series Logic Analysis System The Agilent E8047B analysis

More information

Agilent Technologies N5990A Test Automation Software Platform. Getting Started Guide

Agilent Technologies N5990A Test Automation Software Platform. Getting Started Guide Agilent Technologies N5990A Test Automation Software Platform Getting Started Guide Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including

More information

Agilent 4338B Milliohm Meter

Agilent 4338B Milliohm Meter Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top

More information

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note Agilent Technologies Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters Application Note INTRODUCTION In today s world, the three-phase AC induction motors are widely used in

More information

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview Reduce your cost of ownership by minimizing time to calibrate and

More information

Selecting RJ Bandwidth in EZJIT Plus Software

Selecting RJ Bandwidth in EZJIT Plus Software Selecting RJ Bandwidth in EZJIT Plus Software Application Note 1577 Introduction Separating jitter into its random and deterministic components (called RJ/DJ separation ) is a relatively new technique

More information

Agilent Test Solutions for Multiport and Balanced Devices

Agilent Test Solutions for Multiport and Balanced Devices Agilent Test Solutions for Multiport and Balanced Devices Duplexer test solutions 8753ES option H39/006 During design and final alignment of duplexers, it is often necessary to see both the transmit-antenna

More information

Agilent 87421A/87422A Power Supply

Agilent 87421A/87422A Power Supply Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration

More information

802.11ac Power Measurement and Timing Analysis

802.11ac Power Measurement and Timing Analysis 802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier

More information

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers N4690 Series, 2-port Microwave ECal 85090 Series, 2-port RF ECal N4430 Series, 4-port ECal Technical Overview Control ECal directly

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors

More information

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview The flexible GSM/EDGE base station test solution with a 3G future... Designed for manufacturing

More information

Agilent Technologies N5393B PCI Express 2.0 (Gen2) Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes

Agilent Technologies N5393B PCI Express 2.0 (Gen2) Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes Agilent Technologies N5393B PCI Express 2.0 (Gen2) Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes Data Sheet Table of Contents Features......................... 3

More information

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates Application Note l Introduction The split post dielectric resonator (SPDR) provides an accurate technique for measuring

More information

High-Definition Multimedia Interface (HDMI) Source/Sink Impedance Compliance Test Test Solution Overview Using the E5071C ENA Option TDR

High-Definition Multimedia Interface (HDMI) Source/Sink Impedance Compliance Test Test Solution Overview Using the E5071C ENA Option TDR High-Definition Multimedia Interface (HDMI) Source/Sink Impedance Compliance Test Using the E5071C ENA Option TDR Keysight Technologies Component Test Division Revision 01.10 2015/03/12 (YS) Reference

More information

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? Application Note In the past, deciding between an equivalent time sampling oscilloscope and a real

More information

Agilent E5100A Network Analyzer

Agilent E5100A Network Analyzer Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications

More information

Agilent 8753ET/8753ES Network Analyzers

Agilent 8753ET/8753ES Network Analyzers Agilent 8753ET/8753ES Network Analyzers 8753ET, 300 khz to 3 or 6 GHz 8753ES, 30 khz to 3 or 6 GHz Configuration Guide System configuration summary The following summary lists the main components required

More information

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note 1304-6

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note 1304-6 Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements Application Note 1304-6 Abstract Time domain measurements are only as accurate as the trigger signal used to acquire them. Often

More information

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide Keysight M9485A PXIe Multiport Vector Network Analyzer Configuration Guide 02 Keysight M9485A PXIe Multiport Vector Network Analyzer - Configuration Guide Ordering Guide The following steps will guide

More information

Agilent Technologies Storage Area Network (SAN) Test System 1730 Series 1, 2 and 4Gb/s Fibre Channel Traffic Generators and Analyzers

Agilent Technologies Storage Area Network (SAN) Test System 1730 Series 1, 2 and 4Gb/s Fibre Channel Traffic Generators and Analyzers Agilent Technologies Storage Area Network (SAN) Test System 1730 Series 1, 2 and 4Gb/s Fibre Channel Traffic Generators and Analyzers Data Sheet Applications Data performance test of Fibre Channel Networking

More information

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Application Note 1 Summary Introduction As a part of the certification

More information

Agilent E5063A ENA Series Network Analyzer

Agilent E5063A ENA Series Network Analyzer Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5063A. Standard furnished item Description

More information

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox Application Note Introduction Of all the signal engines in the N7509A, the most complex is the multi-tone engine. This application

More information

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help

More information

Agilent E6020B FTTx OTDR

Agilent E6020B FTTx OTDR Agilent E6020B FTTx OTDR Fast and Cost-effective Fiber Installation for Access Networks Technical Data Sheet Introducing the New FTTx OTDR Agilent's new E6020B FTTx OTDR is a cost-effective, easy to use

More information

DDR Memory Overview, Development Cycle, and Challenges

DDR Memory Overview, Development Cycle, and Challenges DDR Memory Overview, Development Cycle, and Challenges Tutorial DDR Overview Memory is everywhere not just in servers, workstations and desktops, but also embedded in consumer electronics, automobiles

More information

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz Setting a new standard for low frequency impedance measurements Providing the best combination of accuracy, speed and versatility A New Standard for Impedance

More information

it4036f 120-ps Wideband Phase Delay Description Features Device Diagram Timing Diagram

it4036f 120-ps Wideband Phase Delay Description Features Device Diagram Timing Diagram Description The it436f is an ultra-wideband phase delay with an ECL topology to ensure high-speed operation that accepts either single-ended or differential data input. Its high output voltage, excellent

More information

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance Page 1 Agenda Introduction PCIe 2.0 changes from 1.0a/1.1 Spec 5GT/s Challenges Error Correction Techniques Test tool

More information

Wireless Connectivity Testing

Wireless Connectivity Testing N4010A Test Solutions Flexible verification solutions for developers, integrators, and manufacturers working with Bluetooth, Bluetooth Enhanced Data Rate (EDR), ZigBee, Wireless LAN (WLAN), 802.11 a/b/g,

More information

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers Product Note E5070/71-2 An easy-to-learn and easy-to-use programming language 1. Introduction The Agilent

More information

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes Data Sheet This application is available in the following license variations Order N7248A for user-installed license

More information

Agilent Balanced Measurement Example: Differential Amplifiers

Agilent Balanced Measurement Example: Differential Amplifiers Agilent Balanced Measurement Example: Differential Amplifiers Application Note 1373-7 Introduction Agilent Technologies has developed a solution that allows the most accurate method available for measuring

More information

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes Data Sheet Enhance your InfiniiVision or Infiniium oscilloscope with the analysis power of MATLAB software Develop custom analysis

More information

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet TCA-N TekConnect-to-N DC to 11 GHz (Instrument Dependent) 50 Ω Input (Only) TCA-SMA TekConnect-to-SMA DC to 18 GHz (Instrument Dependent)

More information

Microwave Multiplexer Module

Microwave Multiplexer Module Microwave Multiplexer Module Form Drive s K90 OM K90 OM K90 OM Agilent 44476A Switching signals from D to 8 GHz Triple -to- microwave multiplexers N N N Drive Jumpers W W W HP876B HP876B HP876B L90 V TO

More information

Agilent 4339B/4349B High Resistance Meters

Agilent 4339B/4349B High Resistance Meters Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance

More information

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components

More information

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Application Note The N5970A Interactive Functional Test Software along with the 8960 Series 10 (E5515C) wireless communications

More information

Automotive Ethernet Compliance Testing

Automotive Ethernet Compliance Testing Automotive Ethernet Compliance Testing Dr. Ernst Flemming Product Manager Rohde & Schwarz GmbH & Co. KG Munich, Germany The company group at a glance ı History Established 1933 in Munich, Germany ı Type

More information

Performance Measurement of Wireless LAN Using Open Source

Performance Measurement of Wireless LAN Using Open Source Performance Measurement of Wireless LAN Using Open Source Vipin M Wireless Communication Research Group AU KBC Research Centre http://comm.au-kbc.org/ 1 Overview General Network Why Network Performance

More information

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Application Note RF & Microwave Spectrum Analyzers Table of Contents 3 3 4 4 5 7 8 8 13 13 14 16 16 Introduction Absolute versus relative

More information

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements

More information

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes N546A and N547A USB Compliance Test Software for Infiniium Oscilloscopes Data Sheet The N546A USB compliance test software for Infiniium oscilloscopes gives you a fast and reliable way to verify USB electrical

More information

Agilent 8510-13 Measuring Noninsertable Devices

Agilent 8510-13 Measuring Noninsertable Devices Agilent 8510-13 Measuring Noninsertable Devices Product Note A new technique for measuring components using the 8510C Network Analyzer Introduction The majority of devices used in real-world microwave

More information

The demo guide contains

The demo guide contains The demo guide contains 1. Demo configuration, units are available in the Agilent demstock 2. Remote Demo, a remote setup is available in Böblingen. Booking is possible via a demo outlook calendar. Please

More information

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors Product Overview Introduction Quickly and accurately determine the root cause of your team s most difficult hardware, software, and system

More information

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Use BenchVue software to: Visualize multiple measurements simultaneously Easily capture data, screen shots and

More information

Basler racer. Line Scan Cameras. Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate

Basler racer. Line Scan Cameras. Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate Basler racer Line Scan Cameras Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate Flexible and easy integration, supported by a very compact design Low power consumption

More information

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments Application Note Table of Contents Introduction 2 U2000 Series USB Power 3 Sensor s Compatibility with Agilent Instruments

More information

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation

More information

Basler beat AREA SCAN CAMERAS. High-resolution 12 MP cameras with global shutter

Basler beat AREA SCAN CAMERAS. High-resolution 12 MP cameras with global shutter Basler beat AREA SCAN CAMERAS High-resolution 12 MP cameras with global shutter Outstanding price / performance ratio High speed through Camera Link interface Flexible and easy integration Overview Convincing

More information

Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide

Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide The Agilent Technologies E6481A OPAS32 is an engineering information management and analysis software

More information

Cable Analysis and Fault Detection using the Bode 100

Cable Analysis and Fault Detection using the Bode 100 Cable Analysis and Fault Detection using the Bode 100 By Stephan Synkule 2014 by OMICRON Lab V1.3 Visit www.omicron-lab.com for more information. Contact support@omicron-lab.com for technical support.

More information

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started

More information

PCI Express Transmitter Electrical Validation and Compliance Testing with Agilent Infiniium Oscilloscopes

PCI Express Transmitter Electrical Validation and Compliance Testing with Agilent Infiniium Oscilloscopes PCI Express Transmitter Electrical Validation and Compliance Testing with Agilent Infiniium Oscilloscopes Application Note 1496 Who should read this application note? This application note is intended

More information

Building Hybrid Test Systems, Part 1

Building Hybrid Test Systems, Part 1 Building Hybrid Test Systems, Part 1 Laying the groundwork for a successful transition Application Note 1465-32 In the 1990s, GPIB- and VXI-based systems dominated test system architectures. With the introduction

More information

TI GPS PPS Timing Application Note

TI GPS PPS Timing Application Note Application Note Version 0.6 January 2012 1 Contents Table of Contents 1 INTRODUCTION... 3 2 1PPS CHARACTERISTICS... 3 3 TEST SETUP... 4 4 PPS TEST RESULTS... 6 Figures Figure 1 - Simplified GPS Receiver

More information

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR

Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR 1 Table of Contents 1. Revision History... 3 2. Purpose... 3 3. References...

More information

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE 802.3 100GCU Singapore, 2011/03 V1.

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE 802.3 100GCU Singapore, 2011/03 V1. Recommendations for TDR configuration for channel characterization by S-parameters Pavel Zivny IEEE 802.3 100GCU Singapore, 2011/03 V1.0 Agenda TDR/TDT measurement setup TDR/TDT measurement flow DUT electrical

More information

LLRF. Digital RF Stabilization System

LLRF. Digital RF Stabilization System LLRF Digital RF Stabilization System Many instruments. Many people. Working together. Stability means knowing your machine has innovative solutions. For users, stability means a machine achieving its full

More information

Communicate with Test Instruments Over LAN Using Visual Basic

Communicate with Test Instruments Over LAN Using Visual Basic Communicate with Test Instruments Over LAN Using Visual Basic Application Note 1555 When you order a new test and measurement instrument, you may discover that it has a local area network (LAN) interface

More information

Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer

Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer Jitter in PCIe application on embedded boards with PLL Zero delay Clock buffer Hermann Ruckerbauer EKH - EyeKnowHow 94469 Deggendorf, Germany Hermann.Ruckerbauer@EyeKnowHow.de Agenda 1) PCI-Express Clocking

More information

Transmission of High-Speed Serial Signals Over Common Cable Media

Transmission of High-Speed Serial Signals Over Common Cable Media Transmission of High-Speed Serial February 0 Introduction Technical Note TN066 Designers are often faced with moving serial data from one location to another, over moderate distances, and in the most efficient

More information

Creating Datalogging Applications in Microsoft Excel

Creating Datalogging Applications in Microsoft Excel Creating Datalogging Applications in Microsoft Excel Application Note 1557 Table of contents Introduction 2 Steps for creating a scanning program 2 Using Excel for datalogging 4 Running the application

More information

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper Products: R&S RTO1012 R&S RTO1014 R&S RTO1022 R&S RTO1024 This technical paper provides an introduction to the signal

More information

DSA800 Series Spectrum Analyzer

DSA800 Series Spectrum Analyzer DSA800 Series Spectrum Analyzer Configuration Guide This guide is used to help users to configure DSA800 series spectrum analyzer according to their requirements. You can get an overall understanding of

More information

NETWORK ENABLED EQUIPMENT MONITOR

NETWORK ENABLED EQUIPMENT MONITOR NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone

More information

Calibration and performance test of the Very Front End electronics for the CMS electromagnetic calorimeter

Calibration and performance test of the Very Front End electronics for the CMS electromagnetic calorimeter Calibration and performance test of the Very Front End electronics for the CMS electromagnetic calorimeter Jan Blaha IPN Lyon 10th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD06)

More information

Agilent Technologies 3000 Series Oscilloscopes

Agilent Technologies 3000 Series Oscilloscopes Agilent Technologies 3000 Series Oscilloscopes Data Sheet The performance and features you need at the industry s lowest price Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm

More information

Agilent Technologies Performing Pre-VoIP Network Assessments. Application Note 1402

Agilent Technologies Performing Pre-VoIP Network Assessments. Application Note 1402 Agilent Technologies Performing Pre-VoIP Network Assessments Application Note 1402 Issues with VoIP Network Performance Voice is more than just an IP network application. It is a fundamental business and

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:

More information

xxx Dual AMC box Datasheet v1.1(12.2015)

xxx Dual AMC box Datasheet v1.1(12.2015) xxx Dual AMC box Datasheet v1.1(12.2015) Document version: Preliminary Issue Date: December 8, 2015 Written by: Approved by: Document title: Filip Świtakowski Marcin Kiepiela Dual AMC box - Datasheet Page

More information

Basler scout AREA SCAN CAMERAS

Basler scout AREA SCAN CAMERAS Basler scout AREA SCAN CAMERAS VGA to 2 megapixels and up to 120 fps Selected high quality CCD and CMOS sensors Gigabit Ethernet and FireWire-b interfaces Perfect fit for a variety of applications - extremely

More information

LAN extensions for Instrumentation

LAN extensions for Instrumentation LAN extensions for Instrumentation LXI: It s About Your Time It took years for Ethernet and the Web to transform the way we work. Now it s time for both to transform test systems. That s why leading test

More information

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Vibration analysis and monitoring Compact. Powerful. Modern technology. Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device

More information

Agilent P940xA/C Solid State PIN Diode Switches

Agilent P940xA/C Solid State PIN Diode Switches Agilent P940xA/C Solid State PIN Diode Switches Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any

More information

Improving Chromatic Dispersion and PMD Measurement Accuracy

Improving Chromatic Dispersion and PMD Measurement Accuracy Improving Chromatic Dispersion and PMD Measurement Accuracy White Paper Michael Kelly Agilent Technologies Signal transmission over optical fibers relies on preserving the waveform from transmitter to

More information

High speed pattern streaming system based on AXIe s PCIe connectivity and synchronization mechanism

High speed pattern streaming system based on AXIe s PCIe connectivity and synchronization mechanism High speed pattern streaming system based on AXIe s connectivity and synchronization mechanism By Hank Lin, Product Manager of ADLINK Technology, Inc. E-Beam (Electron Beam) lithography is a next-generation

More information

Digital Audio Broadcasting Receiver Testing Solutions

Digital Audio Broadcasting Receiver Testing Solutions Digital Audio Broadcasting Receiver Testing Solutions Self-Guided Demonstration Using Signal Studio software and PXB, MXG/ESG signal generators for digital audio broadcasting receiver test Featured Products:

More information

APS Performance Testers APS Time Verification MP159x Network Performance Tester

APS Performance Testers APS Time Verification MP159x Network Performance Tester Application Note APS Performance Testers APS Time Verification MP159x Network Performance Tester Introduction This application note demonstrates the Time Verification feature of the Automatic Protection

More information

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System Data Sheet FUJITSU Storage ETERNUS LT260 Tape System Data Sheet FUJITSU Storage ETERNUS LT260 Tape System Easy Scalable Tape Automated Solution for up to 3.5 PB of Data ETERNUS LT TAPE STORAGE SYSTEM The

More information

Basler pilot AREA SCAN CAMERAS

Basler pilot AREA SCAN CAMERAS Basler pilot AREA SCAN CAMERAS VGA to 5 megapixels and up to 210 fps Selected high quality CCD sensors Powerful Gigabit Ethernet interface Superb image quality at all Resolutions and frame rates OVERVIEW

More information

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT The VHF/UHF Dual cast Digital Transposers/ Digital Transmitters set new standards for ATV and DVB-T transposer and transmitter technology by combining top performance with an extensive number of features

More information

Description: Multiparameter System (4 or 8 channels)

Description: Multiparameter System (4 or 8 channels) Model MPA4, 8 ch acquisition system with 6 ns time tagging The MPA4 is a Multiparameter Data Acquisition System Description: Multiparameter System (4 or 8 channels) ADC Settings and Presets Dialog The

More information

Agilent N4010A Wireless Connectivity Test Set

Agilent N4010A Wireless Connectivity Test Set Agilent N4010A Wireless Connectivity Test Set Data Sheet General Introduction The Agilent N4010A Wireless Connectivity Test Set is a measurement solution that enables efficient and lower cost test for

More information

Loop-IP6700 TDMoEthernet

Loop-IP6700 TDMoEthernet Loop- Description Loop- is designed to transport /T1/DTE/E3/DS3 signal with timing plus Ethernet traffic over IP network, electrical or optical. This is a cost effective way of migrating to IP network

More information

Nutaq. PicoDigitizer 125-Series 16 or 32 Channels, 125 MSPS, FPGA-Based DAQ Solution PRODUCT SHEET. nutaq.com MONTREAL QUEBEC

Nutaq. PicoDigitizer 125-Series 16 or 32 Channels, 125 MSPS, FPGA-Based DAQ Solution PRODUCT SHEET. nutaq.com MONTREAL QUEBEC Nutaq PicoDigitizer 125-Series 16 or 32 Channels, 125 MSPS, FPGA-Based DAQ Solution PRODUCT SHEET QUEBEC I MONTREAL I N E W YO R K I nutaq.com Nutaq PicoDigitizer 125-Series The PicoDigitizer 125-Series

More information