Dell PowerEdge R720 SQL OLTP Virtualization Study

Size: px
Start display at page:

Download "Dell PowerEdge R720 SQL OLTP Virtualization Study"

Transcription

1 Dell PowerEdge R720 SQL OLTP Virtualization Study Measuring performance and power improvements of the new Intel Xeon processor E product family Don Hoffman Solutions Performance Analysis

2 This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The content is provided as is, without express or implied warranties of any kind Dell Inc. All rights reserved. Dell and its affiliates cannot be responsible for errors or omissions in typography or photography. Dell, the Dell logo, EqualLogic, PowerConnect, and PowerEdge are trademarks of Dell Inc. Intel and Xeon are registered trademarks of Intel Corporation in the U.S. and other countries. Microsoft, Windows, SQL Server, and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. VMware, ESXi, vcenter, and vsphere are either trademarks or registered trademarks of VMware Corporation in the United States and/or other countries. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others. March 2012 Rev 1.0 ii

3 Contents Executive summary... 4 Introduction... 4 Test description... 5 Sample environment characterization... 6 Virtualized SQL system configurations... 7 Test methodology... 8 Overview... 8 Data collection overview... 9 Test results... 9 Virtual machine scaling to determine optimal load for each system... 9 Maximum Performance and System DBPM BIOS mode in the R DIMM and 12 DIMM performance of the PowerEdge R Direct performance and power comparison between the Dell PowerEdge R720 and PowerEdge R Idle power draw comparison Total operations per minute comparison Processing efficiency comparison Conclusion Appendix A: References Appendix B: Additional configuration details Tables Table 1. DVD Store database size description... 6 Table 2. System test configurations... 7 Table 3. Supporting infrastructure configurations... 8 Table 4. Performance and power draw of each BIOS mode Table 5. PowerEdge R DIMM and 12 DIMM comparison Table 6. Detailed system test configurations Table 7. Additional infrastructure and BIOS configurations Figures Figure 1. DVD Store test environment... 7 Figure 2. OPM scaling by number of VMs per SUT Figure 3. PowerEdge R720 Maximum Performance and System DBPM total OPM Figure 4. PowerEdge R720 Maximum Performance and System DBPM Performance per Watt Figure 5. PowerEdge R720 OPM per Watt 16 DIMM and 12 DIMM Figure 6. PowerEdge R720 and R710 idle power draw (lower is better) Figure 7. PowerEdge R720 and R710 total OPM Figure 8. PowerEdge R720 and R710 processing efficiency (OPM/watt) iii

4 Executive summary Dell s Solutions Performance Analysis team conducted a study to measure the performance and the performance per watt in a virtualized environment to compare the Intel Xeon processor 5600 series on the Dell PowerEdge R710 against the new Intel Xeon processor E product family on the Dell PowerEdge R720. The configurations chosen were aimed at maximizing the performance of each system by equipping them with the top speed processors available, a 10Gb network connection to a backend SAN, and sufficient memory to run the workload at 100% processor utilization for both processor architectures tested. The study indicates that the Intel Xeon E processors offer significant performance gains while doing so with higher processor efficiency (performance per watt).the Intel Xeon E processors are also able to scale out further, supporting a higher number of virtual machines (VMs) at optimal performance. Key findings of the study include: The Dell PowerEdge R720 with Intel Xeon E processors provided 53% higher virtualized online transaction processing (OLTP) performance than the PowerEdge R710 with Intel Xeon X5690 processors. The R720 configuration with Intel Xeon E processors obtained 371,743 orders per minute (OPM) in a virtualized environment, as compared to the R710 configuration with Intel Xeon X5690 processors, which scored 242,622 OPM. The Dell PowerEdge R720 with Intel Xeon E processors obtained 26% higher performance per watt than the PowerEdge R710 with Intel Xeon 5690 processors. The R720 configuration with Intel Xeon E processors obtained a performance per watt score of 907 in a virtualized environment, as compared to the R710 configuration with Intel Xeon 5690 processors, which achieved a performance per watt score of 718. The Dell PowerEdge R720 with Intel Xeon E processors used 26% less overall power at idle than the PowerEdge R710 with Intel Xeon X5690 processors. The R720 with Intel Xeon E processors used an average of 136W at idle, as compared to the R710 configuration with Intel Xeon X5690 processors which used an average of 185W. Introduction In order to provide a better understanding for virtualization performance, this study describes specific application performance in a virtualized environment. The servers used in this study are the Dell PowerEdge R720 with Intel Xeon E series processors, and the previous-generation Dell PowerEdge R710 with Intel Xeon X5600 series processors. Many other virtualization benchmarks exist, such as VMmark and SPECvirt, but this study is intended to answer a common question that cannot be answered by other benchmarks: What is the performance of a virtualized Microsoft SQL Server scenario on a mainstream dual-socket Dell server? 4

5 Considerations include: Comparing Microsoft SQL Server virtualized performance between the Dell PowerEdge R720 with Intel Xeon E processors against the previous-generation Dell PowerEdge R710 equipped with Intel Xeon X5600 processors. The optimal number of VMs for each system will be determined by calculating the total OPM while scaling out the number of VMs assigned to each server. Comparing the power utilization of the Dell PowerEdge R720 with Intel Xeon E processors against the Dell PowerEdge R710 with Intel Xeon X5600 processors at idle and 100% CPU utilization levels. Comparing the performance per watt of the Dell PowerEdge R720 with Intel Xeon E processors against the Dell PowerEdge R710 with Intel Xeon X5600 processors. Comparing the power utilization, performance, and performance per watt of the Dell PowerEdge R720 with Intel Xeon E processors when running in System DBPM (demandbased power management) BIOS profile against the same system running in Maximum Performance BIOS profile. Comparing the power utilization, performance, and performance per watt of the Dell PowerEdge R720 with Intel Xeon E processors between 16 DIMM and 12 DIMM configurations. This study is not intended to be a comprehensive analysis of virtualization performance between Dell PowerEdge platforms; only the R720 and R710 were chosen to characterize the relative gains in performance and power efficiency achieved in the current generation of Dell servers. In addition, because ESXtop was actively logging performance counters during these runs, the numbers published in this study are not directly comparable to other published DVD Store results by either Dell or its competitors. Test description DVD Store Version 2 (DS2) is a complete online e-commerce test application with a back-end database component, a Web application layer, and driver programs. The goal in designing the database component as well as the mid-tier application was to utilize many advanced database features (for example, transactions, stored procedures, triggers, and referential integrity) while keeping the database easy to install and understand. The DS2 workload may be used to test databases or as a stress tool for any purpose. The distribution includes code for Microsoft SQL Server, Oracle, and MySQL databases. Included in the release are data generation programs; shell scripts to build data for 10 MB, 1 GB, and 100 GB 5

6 versions of the DVD Store; database build scripts and stored procedures; PHP Web pages; and a C# driver program. 1 Database workload sizes can be small, medium, or large, depending on environment setup. See Table 1 for details. Table 1. DVD Store database size description Database Orders Size Products Customers Small 10 MB 20,000 1,000/month 10,000 Medium 1 GB 2,000, ,000/month 100,000 Large 100 GB 200,000,000 10,000,000/month 1,000,000 Sample environment characterization To measure consolidated VM infrastructure host performance in a simulated e-commerce scenario, a full end-to-end solution was implemented. This environment consists of a physical server (host) running VMware ESX 4.1. This is referred to as the system under test (SUT) in the diagram. In addition to the SUT, the environment contains an environment controller system and a workload driver system. The environment controller is running Windows Server 2008 SP1. The intent of this system is to manage the VMware vcenter and vsphere client and act as a logging device for the power analyzer. The workload driver system is running Windows Server 2008 R2 Enterprise. This system is used to create simultaneous SQL user workload instances on the VMs that are being tested. In addition to these three physical systems, the environment contains a 10Gig Ethernet Dell PowerConnect 8024F switch, four Dell EqualLogic PS6010 SANs, and a Yokogawa WT210 power analyzer. The PowerConnect switch enables communications between the VMs and controller systems (workload driver and environment controller), and between the system under test (SUT) and the iscsibased EqualLogic storage backend. The power analyzer is connected to the environment controller system through a serial cable. The power analyzer takes one-second snapshots of all power readings and the controller logs this data during both the idle and active portions of the benchmark runs. 1 Test description information from Dell Enterprise Technology Center website: 6

7 Figure 1. DVD Store test environment Virtualized SQL system configurations Configurations used in the test environment are shown in Table 2 and Table 3. Table 2. System test configurations Platform PowerEdge R720 PowerEdge R710 Operating system VMware ESXi 4.1 Update 2 Processor model 2 x Intel Xeon E x Intel Xeon X5690 Processor frequency 2900 MHz 3467 MHz Memory details 12 x 8GB 2Rx4 LV RDIMMs 12 x 8GB 2Rx4 LV RDIMMs Memory frequency 1333 MT/s 1333 MT/s Internal storage 2 x GB 10K rpm SAS (RAID 1) BIOS power management setting Maximum Performance and System DBPM were tested 7

8 Platform PowerEdge R720 PowerEdge R710 Physical cores Logical processors # 2-vCPU VMs (optimal OPM) 16 6 Table 3. Environment controller system Supporting infrastructure configurations SQL workload driver system PowerEdge 1950 Windows Server 2008 Enterprise SP1 2 x Intel Xeon Processor E5410, 2.33 GHz Memory: 16 GB RAM Disk configuration: 2 x 73 GB SAS (RAID 1) Networking PowerConnect 8024F running at 10GbE 1 network power used per EqualLogic SAN (4 total) 1 network power used for SUT 1 port used as management port (via vsphere) Jumbo frames enabled on switch and SANs PowerEdge R905 Windows Server 2008 R2 Enterprise 4 x AMD Opteron 8435, 2.60 GHz Memory: 96 GB RAM Disk configuration: 2 x 146 GB SAS (RAID 1) Power analyzer Monitors SUT only Measures all power data during active portion of the benchmark Average watts during active and idle periods measured during official run Test methodology Overview The following methodology was used in the testing procedure: Determined the optimal number of virtual machines that each SUT can support. Each SUT was tested with 6, 12, 16, 18, and 20 VMs and the total OPM recorded. The number of VMs that provided the higher total OPM was the number chosen to test that particular server for the remainder of the study. Exercised all enabled VMs for a 10-minute run time. Recorded Performance metric, SUT Performance counters, and Power Measurements. Note: The performance metric recorded is OPM (orders per minute a measure of the number of orders processed during the benchmark runtime). 8

9 Data collection overview The following steps were used in collecting data: 1. Determined the number of VMs to enable during testing by scaling the number of VMs from 6 to 20 and recording the total OPM for each level. 2. Built a medium-size SQL database on each VM using DVD Store scripts. 3. Backed up each SQL database to a restore file, allowing the database to be restored from a pristine state, and then deleted all VM databases. 4. Restored all databases from the backup restore file and rebooted all VMs. 5. Performed a warm-up run to prepare databases for the official run, allowing each database to warm up individually and allowing a 10-minute idle period after warm up to allow VMs to return to a steady state. 6. Performed the official run starting all VMs simultaneously using a script. The power analyzer began measuring system power at the start of the official run and an ESX host was triggered to start ESXtop batch session during the official run. (Note: The VMware ESXtop tool gathered system-related performance counters for profiling CPU usage during official run.) 7. Checked the official run data for performance stability, collecting data if stable, and restarting the process if high variation was present. Data collected during the official run included: Average watts used during the official run (power metric) Average of the total ESXtop CPU counters during the official run (CPU percentage) VM throughput in OPM; the metric used in this study is an aggregate OPM measurement of all enabled VMs and is represented as performance in the test results Test results Virtual machine scaling to determine optimal load for each system In comparing the Dell PowerEdge R720 with the previous-generation Dell PowerEdge R710, it was necessary to determine the optimal loading of VMs on each system due to the architectural differences in the processors. The R720 features the new Intel Xeon E series processors while the R710 comes equipped with the Intel Xeon 5600 series processors. The top speed E processor has 8 physical processing cores with 20 MB L3 cache while the top speed X5690 processor has 6 physical processing cores with 12 MB L3 cache. The first test in this study was to determine how many VMs to assign each server for the remainder of the testing. To allow each system to perform at its highest level for the scaling study, each system was set to Maximum Performance mode in the BIOS and configured with 2 DIMMs per memory channel. The Intel Xeon X5690 processor has 3 memory channels per processor, where the Intel Xeon E processor has 4 memory channels per processor. For a dual processor configuration, the R720 is optimally configured with 16 DIMMs and the R710 is optimally configured at 12 DIMMs. Later in this study, the 9

10 effects of setting the system performance mode to System DBPM and reducing the R720 DIMM count to be equal to the R710 is investigated. The results of this scaling study (illustrated in Figure 2) show that the R710 produces a maximum OPM (244,349) at 6 VMs and the R720 a maximum OPM (385,780) at 16 VMs. This optimal number of VMs will be used for the rest of this study for each system. Figure 2. OPM scaling by number of VMs per SUT This first comparison highlights a very important feature of the new Dell PowerEdge R720. With more and higher performing processing cores, the PowerEdge R720 is more scalable and can support a greater number of heavily loaded VMs without sacrificing individual VM performance. Maximum Performance and System DBPM BIOS mode in the R720 Maximum system performance is not the only consideration in this head-to-head comparison. System power draw is also an important factor in customer experience. Significant engineering resources go into optimizing the power and performance of each of the Dell PowerEdge BIOS profiles. This next study investigates the total performance (OPM) and average active power draw (Watts) of the Maximum Performance and System DBPM BIOS profiles. The processing efficiency of the system, measured in Performance per Watt (OPM/Watt), is a very important measurement that considers the power usage of the system, not just raw performance. The following comparison (shown in Figure 3) between Maximum Performance and System DBPM modes on the R720 was run with 16 VMs, the optimal number for this server. 10

11 Figure 3. PowerEdge R720 Maximum Performance and System DBPM total OPM Only 3.0% OPM difference between modes This first comparison shows that there is only a 3.0% performance difference between the two BIOS modes. This is very significant when considering the power savings that are possible when using the System DBPM mode. The next section of this study measures the average active power draw during the DVD Store runs for both BIOS modes and computes which mode provides the highest processing efficiency running this workload. Table 4. Performance and power draw of each BIOS mode PowerEdge R720 Maximum Performance System DBPM % difference OPM 385, , % Average power W W -6.6% OPM per watt % 11

12 Figure 4. PowerEdge R720 Maximum Performance and System DBPM Performance per Watt System DBPM gives +3.9% OPM/Watt improvement While there is a 3% drop in overall OPM performance, the power draw drops by 6.6% when moving to System DBPM mode. This significantly lower power draw results in a +3.9% improvement in overall processing efficiency. System DBPM provides the best performance per watt out of the available BIOS modes. Because we want to provide the best possible performance per watt scores the System DBPM BIOS mode will be used for both servers for the remainder of the comparisons. 16 DIMM and 12 DIMM performance of the PowerEdge R720 In comparing the PowerEdge R720 against the PowerEdge R710, there is a disparity in the number of DIMMs in the system when optimally populated. Intel architectures give the best performance with two DIMMs per memory channel on each processor. Because of this, the PowerEdge R720 was originally tested with 16 DIMMs and the PowerEdge R710 with 12 DIMMs. Because this study also considers power consumption, it would be unfair to populate the R720 with additional DIMMs and raise its power draw artificially. This next study analyzes the overall performance, power draw, and performance per watt of the R720 when configured with 16 and 12 DIMMs. This study is done with the System DBPM BIOS profile, which was proven to give the best Performance per watt. 12

13 Table 5. PowerEdge R DIMM and 12 DIMM comparison PowerEdge R DIMMs 12 DIMMs % difference OPM 374, , % Average power W W -3.7% OPM per watt % Figure 5. PowerEdge R720 OPM per Watt 16 DIMM and 12 DIMM 12 DIMM configuration provides +3.1% OPM/watt improvement There is a negligible 0.7% drop in overall OPM performance when configuring the R720 with 12 DIMMs instead of 16 DIMMs. The average active power draw drops by 3.7% and this increase in efficiency translates into a 3.1% improvement in the OPM/watt metric. This comparison proves that the R720 can handle unbalanced memory configurations very well and customers can be confident in scaling the installed memory to the exact capacity they need. This is the last data point needed in selecting the optimal PowerEdge R720 configuration. The rest of this study focuses on the Dell PowerEdge R720 and the PowerEdge R710 in equivalent configurations that will allow for direct comparison. 13

14 Direct performance and power comparison between the Dell PowerEdge R720 and PowerEdge R710 Idle power draw comparison The idle power usage of the two systems is the first comparison to consider. Both the PowerEdge R720 and PowerEdge R710 systems were set to System DBPM mode in the BIOS and both systems had 12 x 8GB 1333 MT/s LV RDIMM memory configurations. The power measurements were taken when the systems were at complete idle, having set inactive for 10 minutes between runs. The PowerEdge R720 server drew 136.2W at system idle and the R710 drew 185W at system idle. The lower power draw is better and the PowerEdge R720 consumed 26% less power at idle than the PowerEdge R710. Figure 6. PowerEdge R720 and R710 idle power draw (lower is better) The PowerEdge R720 uses 26% less power at idle than R710 Total operations per minute comparison The Dell PowerEdge R720 features the Intel Xeon E processor family, which has a greater number of faster cores than the previous generation PowerEdge R710 with the Intel Xeon 5600 series processor. The additional performance capacity allows the R720 to support more VMs than the R710 and to operate them at a faster rate, which was shown in the initial VM scaling study in this white paper. This advantage is clearly shown when comparing the total OPM achieved by the R720 and R710 when running at the optimal number of VMs for each system s processor architecture. The R720 was able to 14

15 process 371,743 OPM compared to the R710 which was able to process 242,622 OPM. The Dell PowerEdge R720 was able to process 53% more OPM than the PowerEdge R710, a substantial improvement over just one generation of servers. Figure 7. PowerEdge R720 and R710 total OPM 53% greater OPM with the Dell PowerEdge R720 Processing efficiency comparison Considering total active power draw is the variable to consider in this server comparison. Not only do customers want a system that performs at a high level, but also one that does so while drawing the least amount of power possible. Calculating the total OPM/watt shows the measure of a system s processing efficiency. The formula for calculating OPM/watt is as follows: Aggregate performance (OPM) / Average power consumed = OPM per Watt (OPM/watt) The Dell PowerEdge R720 provided better Performance per Watt than the previous generation PowerEdge R710. The R720 scored OPM/watt compared to the R710, which scored OPM/watt. This gives the R720 an advantage of over 26% when compared to the R710. Not only does the R720 offer higher processing power than the R710, but it does so more efficiently as well. 15

16 Figure 8. PowerEdge R720 and R710 processing efficiency (OPM/watt) 26% greater performance per watt with the Dell PowerEdge R720 Conclusion The goal of this study was to characterize the performance and power impacts of the new Dell PowerEdge R720 server featuring Intel Xeon E processors from the previous generation Dell PowerEdge R710 with Intel Xeon 5600 series processors using a virtualized database workload. Actual customer environments are unlikely to be running continuously at 100% processor utilization levels, but the relative scaling achieved with the transition to the PowerEdge R720 should still be indicative of the merits of the Intel Xeon processor E product family and the overall design of the Dell PowerEdge R720. Based on the data contained in this study, the PowerEdge R720 with E processors provides considerable performance and performance per watt advantages while reducing the overall system power at idle over the previous generation Intel Xeon processors in the PowerEdge R710. The PowerEdge R720 with Intel Xeon E processors is the dual-socket platform of choice for maximum performance and scalability with additional processing cores and higher capacity memory support, as well as reduced overall power usage due to improved processing efficiency. For customers who desire a different form factor, this same architecture is also offered in a 1U server with the Dell PowerEdge R620 and in a tower configuration with the Dell PowerEdge T

17 Appendix A: References The DVD Store Virtualized SQL test methodology and overall structure of this white paper are due in large part to previous studies that were done before, as well as technical manuals and documents. Below are listed the key sources of information this study drew upon. Dell PowerEdge R910 SQL OLTP Virtualization Study: Measuring Performance and Power Improvements of New Intel Xeon E7 Processors and Low-Voltage Memory by Waseem Raja and John Beckett, attachments.wetpaintserv.us/jd7st0srn16bzholimozoq Dell PowerEdge Intraline SQL OLTP Virtualization Study by Louis Barton and Greg Darnell. This is an internally published white paper not available publically online. Configuring VMware vsphere Software iscsi With Dell EqualLogic PS Series Storage, en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/ aspx How do I configure the optimal switch settings for IP based SAN? by Naveen Iyengar, en.community.dell.com/techcenter/enterprise-solutions/w/oracle_solutions/1422.aspx Dell EqualLogic Configuration Guide: A guide to building an iscsi based SAN solution with Dell EqualLogic PS Series Arrays, en.community.dell.com/techcenter/storage/w/wiki/equallogicconfiguration-guide.aspx 17

18 Appendix B: Additional configuration details Table 6. Detailed system test configurations Platform PowerEdge R720 PowerEdge R710 Processor model 2 x Intel Xeon E x Intel Xeon X5690 Processor frequency 2900 MHz 3467 MHz Processor L3 cache 20 MB 12 MB Physical cores Logical processors Memory frequency 1333 MT/s 1333 MT/s Memory details 12 x 8 GB 2Rx4 LV RDIMMs 12 x 8 GB 2Rx4 LV RDIMMs Internal storage 2 x GB 10K rpm SAS (RAID 1) HBA PERC H710p mini PERC H700 PCIe BIOS power management setting Maximum Performance and System DBPM were tested Physical cores Logical processors BIOS version idrac version idrac7 Enterprise (Build 69) idrac6 Enterprise Total NIC ports used 1 x 10Gb PCIe, 1 x 1Gb LOM 1 x 10Gb PCIe, 1 x 1Gb LOM 10Gb Ethernet NIC 10Gb Intel XF PCI-E FC single port 10Gb Intel XF PCI-E FC single port 1Gb Ethernet onboard NIC Intel Gigabit 4P I350-t rndc Broadcom NetXtreme II (BCM5709C) Network firmware version Power supply quantity and rating 1 x 870W 1 x 750W Line voltage used for testing 208V 208V 18

19 Table 7. Additional infrastructure and BIOS configurations Virtual environment details Platform PowerEdge R720 PowerEdge R710 VMware ESXi version OS version installed per VM Windows 2008 Enterprise R2 x64 Windows 2008 Enterprise R2 x64 SQL version installed per VM Microsoft SQL 2008 R2 Microsoft SQL 2008 R2 Number of VMs (optimal configuration) 16 6 Logical processors per VM 2 4 EqualLogic configuration EqualLogic systems in use 4 4 EqualLogic system type EqualLogic PS6010 (RAID-10) EqualLogic PS6010 (RAID-10) Total storage per PS TB 3.66 TB Size and # of HDDs/PS x 600 GB 16 x 600 GB BIOS settings Turbo boost Enabled Enabled Processor prefetchers All enabled All enabled C-states Enabled Enabled C1E Enabled Enabled Logical processors Enabled Enabled Node interleaving Disabled Disabled Power management Maximum Performance and System DBPM both tested 19

Power Comparison of Dell PowerEdge 2950 using Intel X5355 and E5345 Quad Core Xeon Processors

Power Comparison of Dell PowerEdge 2950 using Intel X5355 and E5345 Quad Core Xeon Processors Power Comparison of Dell PowerEdge 2950 using Intel X5355 and E5345 Quad Core Xeon Processors By Scott Hanson and Todd Muirhead Dell Enterprise Technology Center Dell Enterprise Technology Center dell.com/techcenter

More information

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays Database Solutions Engineering By Murali Krishnan.K Dell Product Group October 2009

More information

Oracle Database Scalability in VMware ESX VMware ESX 3.5

Oracle Database Scalability in VMware ESX VMware ESX 3.5 Performance Study Oracle Database Scalability in VMware ESX VMware ESX 3.5 Database applications running on individual physical servers represent a large consolidation opportunity. However enterprises

More information

Optimizing SQL Server Storage Performance with the PowerEdge R720

Optimizing SQL Server Storage Performance with the PowerEdge R720 Optimizing SQL Server Storage Performance with the PowerEdge R720 Choosing the best storage solution for optimal database performance Luis Acosta Solutions Performance Analysis Group Joe Noyola Advanced

More information

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820 This white paper discusses the SQL server workload consolidation capabilities of Dell PowerEdge R820 using Virtualization.

More information

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This

More information

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance This white paper compares the performance of blade-to-blade network traffic between two enterprise blade solutions: the Dell

More information

Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4

Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4 Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4 Solutions for Large Environments Virtualization Solutions Engineering Ryan Weldon and Tom Harrington THIS WHITE PAPER IS FOR

More information

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture Dell Compellent Product Specialist Team THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

Pivot3 Reference Architecture for VMware View Version 1.03

Pivot3 Reference Architecture for VMware View Version 1.03 Pivot3 Reference Architecture for VMware View Version 1.03 January 2012 Table of Contents Test and Document History... 2 Test Goals... 3 Reference Architecture Design... 4 Design Overview... 4 The Pivot3

More information

Microsoft Exchange 2010 on Dell Systems. Simple Distributed Configurations

Microsoft Exchange 2010 on Dell Systems. Simple Distributed Configurations Microsoft Exchange 2010 on Dell Systems Simple Distributed Configurations Global Solutions Engineering Dell Product Group Microsoft Exchange 2010 on Dell Systems Simple Distributed Configurations This

More information

Achieving a High Performance OLTP Database using SQL Server and Dell PowerEdge R720 with Internal PCIe SSD Storage

Achieving a High Performance OLTP Database using SQL Server and Dell PowerEdge R720 with Internal PCIe SSD Storage Achieving a High Performance OLTP Database using SQL Server and Dell PowerEdge R720 with This Dell Technical White Paper discusses the OLTP performance benefit achieved on a SQL Server database using a

More information

White Paper. Recording Server Virtualization

White Paper. Recording Server Virtualization White Paper Recording Server Virtualization Prepared by: Mike Sherwood, Senior Solutions Engineer Milestone Systems 23 March 2011 Table of Contents Introduction... 3 Target audience and white paper purpose...

More information

Dell Virtual Remote Desktop Reference Architecture. Technical White Paper Version 1.0

Dell Virtual Remote Desktop Reference Architecture. Technical White Paper Version 1.0 Dell Virtual Remote Desktop Reference Architecture Technical White Paper Version 1.0 July 2010 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES.

More information

Kronos Workforce Central on VMware Virtual Infrastructure

Kronos Workforce Central on VMware Virtual Infrastructure Kronos Workforce Central on VMware Virtual Infrastructure June 2010 VALIDATION TEST REPORT Legal Notice 2010 VMware, Inc., Kronos Incorporated. All rights reserved. VMware is a registered trademark or

More information

Microsoft Office SharePoint Server 2007 Performance on VMware vsphere 4.1

Microsoft Office SharePoint Server 2007 Performance on VMware vsphere 4.1 Performance Study Microsoft Office SharePoint Server 2007 Performance on VMware vsphere 4.1 VMware vsphere 4.1 One of the key benefits of virtualization is the ability to consolidate multiple applications

More information

Active Fabric Manager (AFM) Plug-in for VMware vcenter Virtual Distributed Switch (VDS) CLI Guide

Active Fabric Manager (AFM) Plug-in for VMware vcenter Virtual Distributed Switch (VDS) CLI Guide Active Fabric Manager (AFM) Plug-in for VMware vcenter Virtual Distributed Switch (VDS) CLI Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use

More information

Vendor and Hardware Platform: Fujitsu BX924 S2 Virtualization Platform: VMware ESX 4.0 Update 2 (build 261974)

Vendor and Hardware Platform: Fujitsu BX924 S2 Virtualization Platform: VMware ESX 4.0 Update 2 (build 261974) Vendor and Hardware Platform: Fujitsu BX924 S2 Virtualization Platform: VMware ESX 4.0 Update 2 (build 261974) Performance Section Performance Tested By: Fujitsu Test Date: 10-05-2010 Configuration Section

More information

EMC Unified Storage for Microsoft SQL Server 2008

EMC Unified Storage for Microsoft SQL Server 2008 EMC Unified Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON and EMC FAST Cache Reference Copyright 2010 EMC Corporation. All rights reserved. Published October, 2010 EMC believes the information

More information

High Performance SQL Server with Storage Center 6.4 All Flash Array

High Performance SQL Server with Storage Center 6.4 All Flash Array High Performance SQL Server with Storage Center 6.4 All Flash Array Dell Storage November 2013 A Dell Compellent Technical White Paper Revisions Date November 2013 Description Initial release THIS WHITE

More information

EMC Backup and Recovery for Microsoft SQL Server

EMC Backup and Recovery for Microsoft SQL Server EMC Backup and Recovery for Microsoft SQL Server Enabled by Quest LiteSpeed Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the information in this publication

More information

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1 Performance Study Performance Characteristics of and RDM VMware ESX Server 3.0.1 VMware ESX Server offers three choices for managing disk access in a virtual machine VMware Virtual Machine File System

More information

Microsoft SharePoint Server 2010

Microsoft SharePoint Server 2010 Microsoft SharePoint Server 2010 Small Farm Performance Study Dell SharePoint Solutions Ravikanth Chaganti and Quocdat Nguyen November 2010 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY

More information

Reference Architecture for a Virtualized SharePoint 2010 Document Management Solution A Dell Technical White Paper

Reference Architecture for a Virtualized SharePoint 2010 Document Management Solution A Dell Technical White Paper Dell EqualLogic Best Practices Series Reference Architecture for a Virtualized SharePoint 2010 Document Management Solution A Dell Technical White Paper Storage Infrastructure and Solutions Engineering

More information

High Performance Tier Implementation Guideline

High Performance Tier Implementation Guideline High Performance Tier Implementation Guideline A Dell Technical White Paper PowerVault MD32 and MD32i Storage Arrays THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS

More information

Operating System Recommended Support Contract

Operating System Recommended Support Contract PowerEdge Nodes Dell PowerEdge with Oracle 10g Release 2 Database/RAC Standard Edition on Windows Server 2003 R2 SP2 Standard x64 Edition version 4.1 Updated 01/30/2009 Minimum Hardware/Software Requirements

More information

7 Real Benefits of a Virtual Infrastructure

7 Real Benefits of a Virtual Infrastructure 7 Real Benefits of a Virtual Infrastructure Dell September 2007 Even the best run IT shops face challenges. Many IT organizations find themselves with under-utilized servers and storage, yet they need

More information

EMC Backup and Recovery for Microsoft SQL Server

EMC Backup and Recovery for Microsoft SQL Server EMC Backup and Recovery for Microsoft SQL Server Enabled by EMC NetWorker Module for Microsoft SQL Server Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the

More information

DELL. Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING

DELL. Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING DELL Dell Microsoft Windows Server 2008 Hyper-V TM Reference Architecture VIRTUALIZATION SOLUTIONS ENGINEERING September 2008 1 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL

More information

Virtualized Exchange 2007 Local Continuous Replication

Virtualized Exchange 2007 Local Continuous Replication EMC Solutions for Microsoft Exchange 2007 Virtualized Exchange 2007 Local Continuous Replication EMC Commercial Solutions Group Corporate Headquarters Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com

More information

Dell Desktop Virtualization Solutions Stack with Teradici APEX 2800 server offload card

Dell Desktop Virtualization Solutions Stack with Teradici APEX 2800 server offload card Dell Desktop Virtualization Solutions Stack with Teradici APEX 2800 server offload card Performance Validation A joint Teradici / Dell white paper Contents 1. Executive overview...2 2. Introduction...3

More information

LAMP Performance Characterization and Sizing on VMware ESX Server 2.5.1 and Dell PowerEdge 1855 Blade Servers

LAMP Performance Characterization and Sizing on VMware ESX Server 2.5.1 and Dell PowerEdge 1855 Blade Servers LAMP Performance Characterization and Sizing on VMware ESX Server 2.5.1 and Dell PowerEdge 1855 Blade Servers By Amresh Singh, J. Craig Lowery, Ph.D., C S Prasanna Nanda, Rudramuni B, and Scott Stanford

More information

Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array

Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array Evaluation report prepared under contract with Lenovo Executive Summary Even with the price of flash

More information

Analysis of VDI Storage Performance During Bootstorm

Analysis of VDI Storage Performance During Bootstorm Analysis of VDI Storage Performance During Bootstorm Introduction Virtual desktops are gaining popularity as a more cost effective and more easily serviceable solution. The most resource-dependent process

More information

DELL. Virtual Desktop Infrastructure Study END-TO-END COMPUTING. Dell Enterprise Solutions Engineering

DELL. Virtual Desktop Infrastructure Study END-TO-END COMPUTING. Dell Enterprise Solutions Engineering DELL Virtual Desktop Infrastructure Study END-TO-END COMPUTING Dell Enterprise Solutions Engineering 1 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL

More information

TREND MICRO SOFTWARE APPLIANCE SUPPORT

TREND MICRO SOFTWARE APPLIANCE SUPPORT TREND MICRO SOFTWARE APPLIANCE SUPPORT What Trend Micro solutions support Software Appliance deployments? The following solutions support the software appliance form factor, and the subsequent hardware

More information

Frequently Asked Questions: EMC UnityVSA

Frequently Asked Questions: EMC UnityVSA Frequently Asked Questions: EMC UnityVSA 302-002-570 REV 01 Version 4.0 Overview... 3 What is UnityVSA?... 3 What are the specifications for UnityVSA?... 3 How do UnityVSA specifications compare to the

More information

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION A DIABLO WHITE PAPER AUGUST 2014 Ricky Trigalo Director of Business Development Virtualization, Diablo Technologies

More information

Dell Reference Configuration for Hortonworks Data Platform

Dell Reference Configuration for Hortonworks Data Platform Dell Reference Configuration for Hortonworks Data Platform A Quick Reference Configuration Guide Armando Acosta Hadoop Product Manager Dell Revolutionary Cloud and Big Data Group Kris Applegate Solution

More information

EMC Virtual Infrastructure for Microsoft SQL Server

EMC Virtual Infrastructure for Microsoft SQL Server Microsoft SQL Server Enabled by EMC Celerra and Microsoft Hyper-V Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the information in this publication is accurate

More information

HP SN1000E 16 Gb Fibre Channel HBA Evaluation

HP SN1000E 16 Gb Fibre Channel HBA Evaluation HP SN1000E 16 Gb Fibre Channel HBA Evaluation Evaluation report prepared under contract with Emulex Executive Summary The computing industry is experiencing an increasing demand for storage performance

More information

Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study

Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study White Paper Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study 2012 Cisco and/or its affiliates. All rights reserved. This

More information

EMC CLARiiON CX3 Series FCP

EMC CLARiiON CX3 Series FCP EMC Solutions for Microsoft SQL Server 2005 on Windows 2003 in VMware ESX Server EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com

More information

Microsoft Exchange Server 2007

Microsoft Exchange Server 2007 Written and Provided by Expert Reference Series of White Papers Microsoft Exchange Server 200 Performance on VMware vsphere 4 1-800-COURSES www.globalknowledge.com Introduction Increased adoption of VMware

More information

VMware VMmark V1.1.1 Results

VMware VMmark V1.1.1 Results VMware VMmark V1.1.1 Results Vendor and Hardware Platform: Lenovo R525 G2 Virtualization Platform: VMware ESX 4.0(build 164009) Performance Section Performance Tested By: Lenovo Test Date: 06/05/2009 Configuration

More information

Summary. Key results at a glance:

Summary. Key results at a glance: An evaluation of blade server power efficiency for the, Dell PowerEdge M600, and IBM BladeCenter HS21 using the SPECjbb2005 Benchmark The HP Difference The ProLiant BL260c G5 is a new class of server blade

More information

HP ProLiant DL585 G5 earns #1 virtualization performance record on VMmark Benchmark

HP ProLiant DL585 G5 earns #1 virtualization performance record on VMmark Benchmark HP ProLiant DL585 G5 earns #1 virtualization performance record on VMmark Benchmark HP Leadership»The HP ProLiant DL585 G5 is a highly manageable, rack optimized, four-socket server designed for maximum

More information

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router April 12, 2012 Table of Contents 1.0 Introduction... 4 2.0 Chelsio Unified Storage Router (USR) SAS-to-...

More information

New!! - Higher performance for Windows and UNIX environments

New!! - Higher performance for Windows and UNIX environments New!! - Higher performance for Windows and UNIX environments The IBM TotalStorage Network Attached Storage Gateway 300 (NAS Gateway 300) is designed to act as a gateway between a storage area network (SAN)

More information

HP reference configuration for entry-level SAS Grid Manager solutions

HP reference configuration for entry-level SAS Grid Manager solutions HP reference configuration for entry-level SAS Grid Manager solutions Up to 864 simultaneous SAS jobs and more than 3 GB/s I/O throughput Technical white paper Table of contents Executive summary... 2

More information

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V Copyright 2011 EMC Corporation. All rights reserved. Published February, 2011 EMC believes the information

More information

EMC Business Continuity for Microsoft SQL Server 2008

EMC Business Continuity for Microsoft SQL Server 2008 EMC Business Continuity for Microsoft SQL Server 2008 Enabled by EMC Celerra Fibre Channel, EMC MirrorView, VMware Site Recovery Manager, and VMware vsphere 4 Reference Architecture Copyright 2009, 2010

More information

Dell High Availability and Disaster Recovery Solutions Using Microsoft SQL Server 2012 AlwaysOn Availability Groups

Dell High Availability and Disaster Recovery Solutions Using Microsoft SQL Server 2012 AlwaysOn Availability Groups Dell High Availability and Disaster Recovery Solutions Using Microsoft SQL Server 2012 AlwaysOn Availability Groups Dell servers and storage options available for AlwaysOn Availability Groups deployment.

More information

Virtualized Exchange 2007 Archiving with EMC EmailXtender/DiskXtender to EMC Centera

Virtualized Exchange 2007 Archiving with EMC EmailXtender/DiskXtender to EMC Centera EMC Solutions for Microsoft Exchange 2007 Virtualized Exchange 2007 Archiving with EMC EmailXtender/DiskXtender to EMC Centera EMC Commercial Solutions Group Corporate Headquarters Hopkinton, MA 01748-9103

More information

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I (

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I ( TEST REPORT MARCH 2009 Server management solution comparison on Dell PowerEdge R710 and HP Executive summary Dell Inc. (Dell) commissioned Principled Technologies (PT) to compare server management solutions

More information

How To Run Apa Hadoop 1.0 On Vsphere Tmt On A Hyperconverged Network On A Virtualized Cluster On A Vspplace Tmter (Vmware) Vspheon Tm (

How To Run Apa Hadoop 1.0 On Vsphere Tmt On A Hyperconverged Network On A Virtualized Cluster On A Vspplace Tmter (Vmware) Vspheon Tm ( Apache Hadoop 1.0 High Availability Solution on VMware vsphere TM Reference Architecture TECHNICAL WHITE PAPER v 1.0 June 2012 Table of Contents Executive Summary... 3 Introduction... 3 Terminology...

More information

VMware vsphere Reference Architecture for Small Medium Business

VMware vsphere Reference Architecture for Small Medium Business VMware vsphere Reference Architecture for Small Medium Business Dell Virtualization Business Ready Configuration b Dell Virtualization Solutions Engineering www.dell.com/virtualization/businessready Feedback:

More information

How To Perform A File Server On A Poweredge R730Xd With Windows Storage Spaces

How To Perform A File Server On A Poweredge R730Xd With Windows Storage Spaces FILE SERVER PERFORMANCE ON THE INTEL PROCESSOR-POWERED DELL POWEREDGE R730XD WITH HYBRID STORAGE Storage constraints in your datacenter can put unnecessary limits on workload performance and affect user

More information

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis White Paper March 2014 2014 Cisco and/or its affiliates. All rights reserved. This document

More information

Business white paper. HP Process Automation. Version 7.0. Server performance

Business white paper. HP Process Automation. Version 7.0. Server performance Business white paper HP Process Automation Version 7.0 Server performance Table of contents 3 Summary of results 4 Benchmark profile 5 Benchmark environmant 6 Performance metrics 6 Process throughput 6

More information

Doubling the I/O Performance of VMware vsphere 4.1

Doubling the I/O Performance of VMware vsphere 4.1 White Paper Doubling the I/O Performance of VMware vsphere 4.1 with Broadcom 10GbE iscsi HBA Technology This document describes the doubling of the I/O performance of vsphere 4.1 by using Broadcom 10GbE

More information

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution EMC Virtual Infrastructure for Microsoft Applications Data Center Solution Enabled by EMC Symmetrix V-Max and Reference Architecture EMC Global Solutions Copyright and Trademark Information Copyright 2009

More information

MS Exchange Server Acceleration

MS Exchange Server Acceleration White Paper MS Exchange Server Acceleration Using virtualization to dramatically maximize user experience for Microsoft Exchange Server Allon Cohen, PhD Scott Harlin OCZ Storage Solutions, Inc. A Toshiba

More information

Desktop Virtualization with VMware Horizon View 5.2 on Dell EqualLogic PS6210XS Hybrid Storage Array

Desktop Virtualization with VMware Horizon View 5.2 on Dell EqualLogic PS6210XS Hybrid Storage Array Desktop Virtualization with VMware Horizon View 5.2 on Dell EqualLogic PS6210XS Hybrid Storage Array A Dell Storage Reference Architecture Enterprise Storage Solutions Cloud Client Computing December 2013

More information

Host Power Management in VMware vsphere 5

Host Power Management in VMware vsphere 5 in VMware vsphere 5 Performance Study TECHNICAL WHITE PAPER Table of Contents Introduction.... 3 Power Management BIOS Settings.... 3 Host Power Management in ESXi 5.... 4 HPM Power Policy Options in ESXi

More information

PARALLELS CLOUD SERVER

PARALLELS CLOUD SERVER PARALLELS CLOUD SERVER Performance and Scalability 1 Table of Contents Executive Summary... Error! Bookmark not defined. LAMP Stack Performance Evaluation... Error! Bookmark not defined. Background...

More information

IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Report Date: 27, April 2015. www.iomark.

IOmark- VDI. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Report Date: 27, April 2015. www.iomark. IOmark- VDI HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VDI- HC- 150427- b Test Copyright 2010-2014 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VM, VDI- IOmark, and IOmark

More information

Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept

Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept White Paper Intel Information Technology Computer Manufacturing Server Virtualization Virtualization with the Intel Xeon Processor 5500 Series: A Proof of Concept Intel IT, together with Intel s Digital

More information

EMC Business Continuity for Microsoft SQL Server Enabled by SQL DB Mirroring Celerra Unified Storage Platforms Using iscsi

EMC Business Continuity for Microsoft SQL Server Enabled by SQL DB Mirroring Celerra Unified Storage Platforms Using iscsi EMC Business Continuity for Microsoft SQL Server Enabled by SQL DB Mirroring Applied Technology Abstract Microsoft SQL Server includes a powerful capability to protect active databases by using either

More information

Philips IntelliSpace Critical Care and Anesthesia on VMware vsphere 5.1

Philips IntelliSpace Critical Care and Anesthesia on VMware vsphere 5.1 Philips IntelliSpace Critical Care and Anesthesia on VMware vsphere 5.1 Jul 2013 D E P L O Y M E N T A N D T E C H N I C A L C O N S I D E R A T I O N S G U I D E Table of Contents Introduction... 3 VMware

More information

EMC Backup and Recovery for Microsoft Exchange 2007 SP2

EMC Backup and Recovery for Microsoft Exchange 2007 SP2 EMC Backup and Recovery for Microsoft Exchange 2007 SP2 Enabled by EMC Celerra and Microsoft Windows 2008 Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the

More information

Cisco Unified Computing System and EMC VNXe3300 Unified Storage System

Cisco Unified Computing System and EMC VNXe3300 Unified Storage System Cisco Unified Computing System and EMC VNXe3300 Unified Storage System An Ideal Solution for SMB Server Consolidation White Paper January 2011, Revision 1.0 Contents Cisco UCS C250 M2 Extended-Memory Rack-Mount

More information

Technical Paper. Moving SAS Applications from a Physical to a Virtual VMware Environment

Technical Paper. Moving SAS Applications from a Physical to a Virtual VMware Environment Technical Paper Moving SAS Applications from a Physical to a Virtual VMware Environment Release Information Content Version: April 2015. Trademarks and Patents SAS Institute Inc., SAS Campus Drive, Cary,

More information

Sizing and Best Practices for Deploying Citrix XenDesktop on VMware vsphere with Dell EqualLogic Storage A Dell Technical Whitepaper

Sizing and Best Practices for Deploying Citrix XenDesktop on VMware vsphere with Dell EqualLogic Storage A Dell Technical Whitepaper Dell EqualLogic Best Practices Series Sizing and Best Practices for Deploying Citrix XenDesktop on VMware vsphere with Dell EqualLogic Storage A Dell Technical Whitepaper Storage Infrastructure and Solutions

More information

Microsoft SharePoint Server 2010

Microsoft SharePoint Server 2010 Microsoft SharePoint Server 2010 Medium Farm Solution Performance Study Dell SharePoint Solutions Ravikanth Chaganti and Quocdat Nguyen August 2010 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY,

More information

Power Efficiency Comparison of Enterprise-Class Blade Servers and Enclosures

Power Efficiency Comparison of Enterprise-Class Blade Servers and Enclosures Power Efficiency Comparison of Enterprise-Class Blade Servers and Enclosures A Dell Technical White Paper John Beckett, Robert Bradfield, and the Dell Server Performance Analysis Team THIS WHITE PAPER

More information

Dell Microsoft SQL Server 2008 Fast Track Data Warehouse Performance Characterization

Dell Microsoft SQL Server 2008 Fast Track Data Warehouse Performance Characterization Dell Microsoft SQL Server 2008 Fast Track Data Warehouse Performance Characterization A Dell Technical White Paper Database Solutions Engineering Dell Product Group Anthony Fernandez Jisha J Executive

More information

MIGRATING LEGACY PHYSICAL SERVERS TO VMWARE VSPHERE VIRTUAL MACHINES ON DELL POWEREDGE M610 BLADE SERVERS FEATURING THE INTEL XEON PROCESSOR 5500

MIGRATING LEGACY PHYSICAL SERVERS TO VMWARE VSPHERE VIRTUAL MACHINES ON DELL POWEREDGE M610 BLADE SERVERS FEATURING THE INTEL XEON PROCESSOR 5500 MIGRATING LEGACY PHYSICAL SERVERS TO VMWARE VSPHERE VIRTUAL MACHINES ON DELL POWEREDGE M610 BLADE SERVERS FEATURING THE INTEL XEON PROCESSOR 5500 SERIES Table of contents... 1 Table of contents... 2 Introduction...

More information

Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems

Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems Using VMware VMotion with Oracle Database and EMC CLARiiON Storage Systems Applied Technology Abstract By migrating VMware virtual machines from one physical environment to another, VMware VMotion can

More information

Initial investment payback analysis: Dell PowerEdge R710 solution with Hyper-V vs. HP ProLiant DL385 solution

Initial investment payback analysis: Dell PowerEdge R710 solution with Hyper-V vs. HP ProLiant DL385 solution TEST REPORT MAY 2009 Initial investment payback analysis: Dell PowerEdge R710 solution with Hyper-V vs. HP ProLiant DL385 solution Executive summary Dell Inc. (Dell) commissioned Principled Technologies

More information

P E R F O R M A N C E S T U D Y. Scaling IBM DB2 9 in a VMware Infrastructure 3 Environment

P E R F O R M A N C E S T U D Y. Scaling IBM DB2 9 in a VMware Infrastructure 3 Environment P E R F O R M A N C E S T U D Y Scaling IBM DB2 9 in a VMware Infrastructure 3 Environment Contents Executive Summary...1 Introduction...1 Test Configuration and Methodology...2 Hardware configuration

More information

Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms

Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms IT@Intel White Paper Intel IT IT Best Practices: Data Center Solutions Server Virtualization August 2010 Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms Executive

More information

Virtuoso and Database Scalability

Virtuoso and Database Scalability Virtuoso and Database Scalability By Orri Erling Table of Contents Abstract Metrics Results Transaction Throughput Initializing 40 warehouses Serial Read Test Conditions Analysis Working Set Effect of

More information

DELL TM PowerEdge TM T610 500 Mailbox Resiliency Exchange 2010 Storage Solution

DELL TM PowerEdge TM T610 500 Mailbox Resiliency Exchange 2010 Storage Solution DELL TM PowerEdge TM T610 500 Mailbox Resiliency Exchange 2010 Storage Solution Tested with: ESRP Storage Version 3.0 Tested Date: Content DELL TM PowerEdge TM T610... 1 500 Mailbox Resiliency

More information

Hardware & Software Specification i2itracks/popiq

Hardware & Software Specification i2itracks/popiq Hardware & Software Specification i2itracks/popiq 3663 N. Laughlin Rd., Suite 200 Santa Rosa, CA 95403 866-820- 2212 www.i2isys.com 1 I2iSystems Hardware and Software Specifications Revised 04/09/2015

More information

IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org

IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org IOmark- VDI Nimbus Data Gemini Test Report: VDI- 130906- a Test Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VDI, VDI- IOmark, and IOmark are trademarks of Evaluator

More information

Host Power Management in VMware vsphere 5.5

Host Power Management in VMware vsphere 5.5 in VMware vsphere 5.5 Performance Study TECHNICAL WHITE PAPER Table of Contents Introduction...3 Power Management BIOS Settings...3 Host Power Management in ESXi 5.5... 5 Relationship between HPM and DPM...

More information

HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief

HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief Technical white paper HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief Scale-up your Microsoft SQL Server environment to new heights Table of contents Executive summary... 2 Introduction...

More information

Performance Evaluation of VMXNET3 Virtual Network Device VMware vsphere 4 build 164009

Performance Evaluation of VMXNET3 Virtual Network Device VMware vsphere 4 build 164009 Performance Study Performance Evaluation of VMXNET3 Virtual Network Device VMware vsphere 4 build 164009 Introduction With more and more mission critical networking intensive workloads being virtualized

More information

Configuration Maximums VMware vsphere 4.0

Configuration Maximums VMware vsphere 4.0 Topic Configuration s VMware vsphere 4.0 When you select and configure your virtual and physical equipment, you must stay at or below the maximums supported by vsphere 4.0. The limits presented in the

More information

Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering

Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays Red Hat Performance Engineering Version 1.0 August 2013 1801 Varsity Drive Raleigh NC

More information

RESOLVING SERVER PROBLEMS WITH DELL PROSUPPORT PLUS AND SUPPORTASSIST AUTOMATED MONITORING AND RESPONSE

RESOLVING SERVER PROBLEMS WITH DELL PROSUPPORT PLUS AND SUPPORTASSIST AUTOMATED MONITORING AND RESPONSE RESOLVING SERVER PROBLEMS WITH DELL PROSUPPORT PLUS AND SUPPORTASSIST AUTOMATED MONITORING AND RESPONSE Sometimes, a power fluctuation can damage a memory module, or a hard drive can fail, threatening

More information

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Applied Technology Abstract This white paper investigates configuration and replication choices for Oracle Database deployment with EMC

More information

VIRTUALIZATION-MANAGEMENT COMPARISON: DELL FOGLIGHT FOR VIRTUALIZATION VS. SOLARWINDS VIRTUALIZATION MANAGER

VIRTUALIZATION-MANAGEMENT COMPARISON: DELL FOGLIGHT FOR VIRTUALIZATION VS. SOLARWINDS VIRTUALIZATION MANAGER VIRTUALIZATION-MANAGEMENT COMPARISON: DELL FOGLIGHT FOR VIRTUALIZATION VS. SOLARWINDS VIRTUALIZATION MANAGER Your company uses virtualization to maximize hardware efficiency in your large datacenters.

More information

Dell EqualLogic Best Practices Series

Dell EqualLogic Best Practices Series Dell EqualLogic Best Practices Series Scaling and Best Practices for Implementing VMware vsphere Based Virtual Workload Environments with the Dell EqualLogic FS7500 A Dell Technical Whitepaper Storage

More information

Scaling in a Hypervisor Environment

Scaling in a Hypervisor Environment Scaling in a Hypervisor Environment Richard McDougall Chief Performance Architect VMware VMware ESX Hypervisor Architecture Guest Monitor Guest TCP/IP Monitor (BT, HW, PV) File System CPU is controlled

More information

Microsoft Exchange Server 2003 Deployment Considerations

Microsoft Exchange Server 2003 Deployment Considerations Microsoft Exchange Server 3 Deployment Considerations for Small and Medium Businesses A Dell PowerEdge server can provide an effective platform for Microsoft Exchange Server 3. A team of Dell engineers

More information

Adaptec: Snap Server NAS Performance Study

Adaptec: Snap Server NAS Performance Study March 2006 www.veritest.com info@veritest.com Adaptec: Snap Server NAS Performance Study Test report prepared under contract from Adaptec, Inc. Executive summary Adaptec commissioned VeriTest, a service

More information

How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1

How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1 How to Configure Intel Ethernet Converged Network Adapter-Enabled Virtual Functions on VMware* ESXi* 5.1 Technical Brief v1.0 February 2013 Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED

More information

IBM System x family brochure

IBM System x family brochure IBM Systems and Technology System x IBM System x family brochure IBM System x rack and tower servers 2 IBM System x family brochure IBM System x servers Highlights IBM System x and BladeCenter servers

More information