1 SCOPE OF WORK FEE PROPOSAL City of Ormond Beach Water and Reclaimed Water Storage Tank Capital Improvements Program Preliminary Engineering Services BACKGROUND The City of Ormond Beach (CITY) owns and operates four (4) potable water storage tanks and six (6) reclaimed water storage tanks of different sizes, configurations, and construction types at various locations throughout the city. Chapter of the Florida Administrative Code (F.A.C) requires that all finished drinking water storage tanks be inspected for structural and coating integrity at least once every five (5) years by personnel under the responsible charge of a professional engineer licensed in Florida. In compliance with this regulatory requirement, the CITY contracted Underwater Solutions, Inc. (USI) to perform a visual inspection and cleaning of their potable water storage tanks in January In addition, the reclaimed water storage tanks were inspected and cleaned in March The inspections involved visual observation of structural and coating integrity of the tanks, tank walls, access ladders, fill line pipes, pump suction pipes, vortex covers, air vents, overflow pipes, roof hatches, manways, catwalks, ladders, support legs (on elevated tanks), and any mechanical fasteners for ladders or level controls. Each inspection includes a written narrative report with photographs. Table 1 shows a list of the potable water and reclaimed water storage tanks inspected under this program along with their capacity and location. Table 1 List of Storage Tanks Location Service Construction Capacity (Gal.) WTP Potable Water Steel (Elevated) 250,000 Jefferson Street Potable Water Concrete 2,500,000 Leeway Potable Water Steel (Elevated) 1,000,000 Standish Potable Water Concrete 1,000,000 Breakaway Trails Reclaimed Water Steel 300,000 Breakaway Trails Reclaimed Water Steel (Elevated) 400,000 Breakaway Trails Reclaimed Water Steel 900,000 Orchard Street Reclaimed Water Concrete 4,000,000 Orchard Street Reclaimed Water Concrete 3,000,000 Shadow Crossings Reclaimed Water Concrete 750,000 With the information retrieved from the Tank Inspection Reports, the CITY desires to develop a 5-year program to correct any deficiencies and perform repairs identified for each of the storage tanks inspected. Task Authorization No. 1 (102014) Page 1 of 4

2 SCOPE OF SERVICES Hazen and Sawyer (CONSULTANT) agrees to perform engineering services related to the development of a 5-year Capital Improvement Program (CIP) to address the repair or rehabilitation of the CITY s potable water and reclaimed water storage tanks. The project will involve a review of the inspection reports prepared by USI, site visits, additional structural analyses, preparation of cost estimates for repairs, and a letter report outlining the repairs and improvements required for each storage tank. The services will also include the development of renderings of a variety of proposed logos to be placed on the City s storage tank(s). The engineering services performed under Scope of Work will include the following tasks: Task 1: Review Tank Inspection Reports CONSULTANT will review the inspection report for each of the storage tanks and evaluate the condition of the items identified in the report narrative and the photographs included in the reports. The following terms will be used to categorize the conditions of the various items: Good Observed to be in good condition. Minor defects may be present, but do not present an obstruction to operation. Fair Less than good condition. This item has not failed, but it is in a state of degradation that will likely require repair or replacement in the near future. Poor The item has failed or is near failure. CONSULTANT will review other existing available information, record drawings, shop drawings, studies, and reports regarding the storage tanks that were inspected. The CITY will provide the requested information if available. In cases where significant structural deficiencies were noted by USI, CONSULTANT will visit the site to make additional observations to determine the severity of the structural damage. It is anticipated that up to three site visits will be made to observe those structural deficiencies. For storage tanks where the structural design was performed by the manufacturer and the design information is not contained on design drawings, CONSULTANT will coordinate with the manufacturer, the structural design engineer, and/or a tank subconsultant to assess the structural condition and develop the necessary repair recommendations. Task 2: Structural Testing and Analysis For structures showing significant signs of structural distress, CONSULTANT will retain the services of a subconsultant (Tank Engineering and Management Consultants, Inc.) to assist CONSULTANT perform structural testing and analyses as necessary. Structural tests may include the following: Pachometer (cover meter) testing Non-destructive testing to confirm remaining metal thickness, etc The results of these tests and analyses will be used for prioritizing repairs and designing the required rehabilitation. Task Authorization No. 1 (102014) Page 2 of 4

3 Task 3: Prepare Renderings for Tank Logos The CITY desires to place a logo on the elevated storage tanks at the WTP and at the Breakaway Trails reclaimed water storage site. The CITY will provide several options for the two elevated storage tanks. CONSULTANT will prepare dimensionally correct renderings of the logos displayed on the two elevated storage tanks for presentation to the City Commission. CONSULTANT will prepare for and attend one meeting with the City Commission for the purpose of presenting the alternative logo configurations for their selection. Task 4: Prepare Letter Report and Estimates of Probable Repair Costs CONSULTANT will prepare estimates of probable repair costs for each of the water and reclaimed water storage tanks based on the information and recommendations presented in the inspection reports, additional structural testing for severely deteriorated structures (if required), and on the CONSULTANT s observations of each facility. Where alternative methods of repair or rehabilitation are warranted, CONSULTANT will prepare a cost estimate of each alternative for comparison. The recommended repairs and the estimated costs associated with each storage tank will be presented in a letter report to the CITY. CONSULTANT will meet with CITY staff to review the letter report and the estimated cost of repairs. SUBCONSULTANT Structural Testing: CONSULTANT will utilize the services of Tank Engineering and Management Consultants, Inc. (TEAM) to assist with the evaluation of the repairs required for the three elevated steel storage tanks. TEAM will assist CONSULTANT review the tank inspection reports, visually observe the defects, perform structural testing and analysis, and assist with the cost estimates for the elevated steel storage tanks. DELIVERABLES CONSULTANT will provide the following information, data, and documents to the CITY: Two (2) full size (22 x34 ) copies and ten (10) half size (11 x17 ) copies of the renderings of the logos for the two (2) elevated storage tanks. Five (5) copies of the letter report outlining the repairs required for the storage tanks. Electronic copies of all meeting summaries will be forwarded to all attendees. CITY REQUIREMENTS The CITY will provide the following: Existing available information for each storage tank including design drawings, record drawings, shop drawings, photographs, studies, and reports. Access to all water and reclaimed water storage tanks. Assistance in arranging meetings with CITY departments. COMPENSATION CONSULTANT shall be paid in accordance with the Time Basis Method of compensation as set forth in Section 5(b) of the Agreement. A budget with a Not-to-Exceed amount of $35,967 for the Task Authorization No. 1 (102014) Page 3 of 4

4 services under this Scope of Work is shown in the attached Fee Proposal, and this budget will not be exceeded without the CITY s written approval. Services to be rendered under this Scope of Work are provided in accordance with Section 1 of the Agreement. TIME SCHEDULE Services described herein will commence upon receipt of the executed Work Authorization Form by CONSULTANT which shall constitute CONSULTANT s Notice to Proceed. The project start date is anticipated to be November 15, 2014 as shown on the attached Project Schedule. The letter report regarding the repairs to the elevated steel tank at the WTP are anticipated to be completed by January 16, 2015 based on the Project Schedule. Task Authorization No. 1 (102014) Page 4 of 4

5 July 16, 2014 Robert B. Cadle, PE Hazen and Sawyer 4767 New Broad Street Orlando, FL RE: Inspection and Engineering Services City of Ormond Beach - Three EWT s Mr. Cadle: Tank Engineering And Management Consultants, Inc. (TEAM Consultants), is pleased to furnish our proposal for performing inspection and engineering services in support of Hazen and Sawyer for the rehabilitation of the above referenced elevated water storage tanks. This project will include the following services: INITIAL ASSESSMENT Task 1 - REVIEW RECENT REPORTS: TEAM personnel will review the reports from a recent inspection contracted by the City. The purpose of this review is to begin establishing a scope of work for tank rehabilitation. Task 2 - ON-SITE INSPECTION: Each tank will be visited by a TEAM inspector in order to assess the tanks current condition and verify the conditions stated in the report. Our inspection will include the following, as applicable: Access to areas of corrosion may require a manlift. Complete visual inspection of the site and foundations. Inspection of the support tower including base plates and anchor bolts. Inspection of the platforms and handrails. Evaluation of the interior and exterior of the tank and stem plates supplemented by random non-destructive ultrasonic measurements, if necessary. Evaluation of the tank interior will be made with water in the tank and the water level lowered to approximately 50% capacity or lower. This will allow a general visual inspection of the interior from the existing interior ladder. Evaluation of metal for isolated or general deterioration, including structural damage due to metal loss. The average area pitted and depth of pits will be determined and recorded. Detailed measurements will be taken and recorded to assist in the design phase, including: UTM steel thickness, structural member sizes and spacing, and appurtenance details. Evaluation of accessories such as obstruction lights, conduit, manholes, overflows, vents, etc. Evaluation of OSHA-related accessories such as ladders, vents, manholes and balcony. PO Box 889 Mulberry, Florida (863) Fax (863)

6 Mr. Robert Cadle, P.E. Hazen and Sawyer City of Ormond Beach Three EWT s July 16, 2014 Collect coating samples from the exterior and have them laboratory tested for the presence of lead, cadmium, and chromium. STANDARDS - We intend to utilize the following standards for the inspection and report: The Engineering Report will utilize American Water Works Association (AWWA) Standards and Manual M42 as criteria for tank evaluation. Personnel access areas will be inspected and evaluated in accordance with Federal OSHA EXCLUSIONS - We do not include: Draining the tanks or opening manholes. Rigging the interior tank for access. The interior will be inspected using existing ladders for access. All work will be done under the direct supervision of a Registered Professional Engineer as required by AWWA M42, App. "C" and FDEP Rule Approximately one-half day of field time will be required for the assessment inspection. Task 3 - REPORT OF INSPECTION: Following the inspection, a Report of Inspection will be submitted for each and will contain detailed information on the condition of the site, structure, accessories, and appurtenances. We will include recommendations concerning any repairs, replacements, etc., with color photographs to illustrate the findings. Economic considerations such as replacement value, estimated cost of repairs and repainting, and the remaining life expectancy of the tank are also included. SCHEDULE: The Report Review can begin within two (2) weeks of your Notice-To-Proceed. The On-Site Inspection can be scheduled within one (1) week of the Report Review. The Report of Inspection will require approximately three (3) weeks to complete following the inspections. FEE SCHEDULE Rate Schedule: Review recent reports... $110/hour On-site inspection... $110/hour Report of Inspection... $110/hour P.E. Review... $130/hour Admin Assistant... $45/hour Mileage... $0.80/mile Per Diem for On-site inspection... $150/day NDT equipment... $100/day Manlift for On-site inspection (if needed)... cost + 5%

7 Mr. Robert Cadle, P.E. Hazen and Sawyer City of Ormond Beach Three EWT s July 16, 2014 PHASE I ASSESSMENT Task 1 Review Recent Reports... NTX $1, Task 2 On-Site Inspection (all three tanks incl. manlift)... NTX $5, Task 3 Report of Inspection... NTX $2, TOTAL PHASE I... NTX $8, This price is firm for sixty (60) days from the date of this proposal. In the event a tank is not open and ready for inspection upon our arrival, standby time will be charged at the applicable categories and rates. PAYMENT FOR SERVICES: Task 1 will be invoiced upon completion. Task 2 will be invoiced upon completion. Task 3 will be invoiced with the Report. We appreciate the opportunity of furnishing this proposal and are looking forward to working with you on this project. Should you have any questions regarding this quotation, please do not hesitate to call us. Sincerely, Tank Engineering And Management Consultants, Inc. Jeff Kitchen Vice President

8 City of Ormond Beach Project No.: HAZEN AND SAWYER Fee Proposal Hazen and Sawyer Project Number: Hazen and Sawyer Project Name: Water and Reclaimed Water Storage Tank Capital Improvements Program Brief Description: Preliminary Engineering Services 10/20/2014 TASK NO. TASK Senior Associate Associate Principal Engineer Principal Designer Office Support Total Man- Hours Total Labor Cost Reimbursable Expenses Subconsultants $ $ $ $ $ Review Tank Inspection Reports Review Tank Inspection Reports $2,211 Review Additional Information $1,366 Perform Site Visits $4,936 $250 Develop Repair Recommendations $6,677 Task 1 Total 85 $15,189 $250 $0 2 Structural Testing and Analysis Coord w/ Structural Testing Subconsult 8 8 $1,645 $8,900 Task 2 Total 8 $1,645 $0 $8,900 3 Prepare Renderings for Tank Logos Prepare Renderings for 2 Tanks $2,836 $100 Attend City Commission Meeting 4 4 $823 Task 3 Total 26 $3,658 $100 $0 4 Prepare Letter Report Review USI Cost Estimates 2 2 $411 Prepare Cost Estimates $1,580 Prepare Letter Report $3,160 Review Letter Report w/ City Staff 4 4 $823 $250 Task 4 Total 39 $5,974 $250 $0 SUBTOTAL HOURS SUBTOTAL $ $13,573 $4,166 $5,973 $2,424 $331 $26,467 $600 $8,900 TOTAL HAZEN AND SAWYER FEE (LABOR COST + REIMBURSABLE EXPENSES + SUBCONSULTANTS) NOTE: Reimbursable Expenses are estimated. Actual expenses will be billed at cost in accordance with the City of Ormond Beach Policies and Procedures $35,967

9

SECTION 15410 GROUND WATER STORAGE TANKS

SECTION 15410 GROUND WATER STORAGE TANKS SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design

More information

Inspection of Water Storage Facilities

Inspection of Water Storage Facilities Inspection of Water Storage Facilities Water Protection Program technical bulletin 4/2004 A technical bulletin, Microbial Contamination of Water Storage Tanks (pub172), was issued September 1995, because

More information

San Antonio Water System Standard Specifications for Construction ITEM 866 SEWER MAIN TELEVISION INSPECTION

San Antonio Water System Standard Specifications for Construction ITEM 866 SEWER MAIN TELEVISION INSPECTION ITEM 866 SEWER MAIN TELEVISION INSPECTION 866.1 DESCRIPTION: The Contractor shall furnish all labor, materials, equipment, and incidentals to provide the televising and a NASSCO-(PACP) standard video,

More information

Exhibit A. SCOPE OF WORK Consulting Services for City of Durham Swimming Pool Facilities Assessment Study

Exhibit A. SCOPE OF WORK Consulting Services for City of Durham Swimming Pool Facilities Assessment Study Exhibit A SCOPE OF WORK Consulting Services for City of Durham Swimming Pool Facilities Assessment Study Basic Services for this project shall include the following services: A Planning Study to assess

More information

Page & Turnbull imagining change in historic environments through design, research, and technology

Page & Turnbull imagining change in historic environments through design, research, and technology DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED

More information

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Record MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT Abandoned Gravity Private Combined Gravity Private Foul Gravity Private Surface Water Gravity Public Combined Gravity Public Foul Gravity Public

More information

Steel Water-Storage Tanks

Steel Water-Storage Tanks Steel Water-Storage Tanks AWWA MANUAL M42 Revised Edition Copyright 2013 American Water Works Association Manual of Water Supply Practices M42, Revised Edition Steel Water-Storage Tanks All rights reserved.

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

Rehabilitation of an Aging Concrete Reservoir Adit Tower

Rehabilitation of an Aging Concrete Reservoir Adit Tower Rehabilitation of an Aging Concrete Reservoir Adit Tower Raymond S. Tombaugh, Senior Coatings Consultant KTA-Tator, Inc. and Mongkol Mahavongtrakul, P.E. Corrosion Control Contract Manager San Francisco

More information

Structure Survey Findings:

Structure Survey Findings: Structure Survey Findings: Visible portions of the following were observed: foundations; structure to walls, columns, floors, roofs, overhang posts, and columns; attached or firmly abutting decks, balconies,

More information

Williamson and Associates, Inc. Report of Building Exterior Condition Evaluation, dated January 2 nd, 2013. (68 pages)

Williamson and Associates, Inc. Report of Building Exterior Condition Evaluation, dated January 2 nd, 2013. (68 pages) INNOVATIVE BUILDING AND ARCHITECTURE CONSULTANTS Mr. Bud Hall Senior Vice President of construction Turnberry Associates 19501 Biscayne Boulevard, Suite 400 Aventura, FL 33180 Subject: The Nashville Hilton

More information

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing

More information

STATEMENT OF WORK (SOW) On-Call Certified Welding Inspections and Nondestructive Testing

STATEMENT OF WORK (SOW) On-Call Certified Welding Inspections and Nondestructive Testing 1.0 INTRODUCTION Colorado Springs Utilities (UTILITIES) is seeking qualified firms to provide verification welding inspection services, nondestructive testing services, and technical reporting to Colorado

More information

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS

CCU Engineering Specifications. Section 003300 PRECAST CONCRETE PRODUCTS CCU Engineering Specifications Section 003300 Effective Date: Nov. 1st, 2011 Page 1 of 5 PRECAST CONCRETE PRODUCTS PART 1 - GENERAL The following specification is intended for use for the design, selection

More information

SECTION 3 ONM & J STRUCTURAL ANALYSIS

SECTION 3 ONM & J STRUCTURAL ANALYSIS Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION

More information

SECTION 33 12 19 FIRE HYDRANTS

SECTION 33 12 19 FIRE HYDRANTS SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.

More information

SECTION 15420 WATER STORAGE TANK PAINTING

SECTION 15420 WATER STORAGE TANK PAINTING SECTION 15420 WATER STORAGE TANK PAINTING PART 1 GENERAL.01 SCOPE A. Section Includes Surface preparation, shop priming, and field coating for interior wet, interior dry, and exterior surfaces of steel

More information

Water Treatment Services Specifications Department of Intellectual and Developmental Disabilities 11437 Milton Wilson Road. Arlington, TN 38002

Water Treatment Services Specifications Department of Intellectual and Developmental Disabilities 11437 Milton Wilson Road. Arlington, TN 38002 Water Treatment Services Specifications Department of Intellectual and Developmental Disabilities 11437 Milton Wilson Road Arlington, TN. 38002 General Scope of Contract I. General Information II. Bidder/Contractor

More information

SECTION 15041 DISINFECTION OF PIPE AND WATER STORAGE FACILITIES

SECTION 15041 DISINFECTION OF PIPE AND WATER STORAGE FACILITIES SECTION 15041 DISINFECTION OF PIPE AND WATER STORAGE FACILITIES PART 1 GENERAL 1.01 DESCRIPTION This section describes requirements for disinfection by chlorination of potable water mains, services, pipe

More information

BLADDER SURGE CONTROL SYSTEM

BLADDER SURGE CONTROL SYSTEM PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures

More information

Anderson Ground Storage Tank No. 1 Painting and Rehabilitation Project SAWS Job No. 13-0129 Solicitation No. B-15-020-DD. ADDENDUM No.

Anderson Ground Storage Tank No. 1 Painting and Rehabilitation Project SAWS Job No. 13-0129 Solicitation No. B-15-020-DD. ADDENDUM No. Anderson Ground Storage Tank No. 1 Painting and Rehabilitation Project SAWS Job No. 13-0129 Solicitation No. B-15-020-DD ADDENDUM No. 1 June 26, 2015 This addendum, applicable to work designated above,

More information

Unity Community Center Metal Roof Installation. Request for Bids

Unity Community Center Metal Roof Installation. Request for Bids Unity Community Center Metal Roof Installation Unity Barn Raisers Request for Bids May 24, 2012 Town of Unity Communities for Maine s Future Bond funding Unity Barn Raisers PO Box 381 32 School Street

More information

SEWER CLEANING, INSPECTION AND ASSESSMENT

SEWER CLEANING, INSPECTION AND ASSESSMENT 3.1 OVERVIEW Chapter 3 SEWER CLEANING, INSPECTION AND ASSESSMENT Preventive maintenance protects the investment of the sanitary sewer collection system infrastructure. Higher frequency cleaning of gravity

More information

SECTION 807 PUMP STATION REHABILITATION

SECTION 807 PUMP STATION REHABILITATION SECTION 807 PUMP STATION REHABILITATION 807-1 DESCRIPTION: Rehabilitation of pump stations shall be defined as the cleaning, removal, repair and/or replacement of any and/or all components including but

More information

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements Fixed Access Ladders Engineering Data Sheet 2-04 Revised: January 1997 Table of Contents 1. Legislative Requirements 2. General 3. Rungs 4. Side Rails 5. Safety Cages 6. Attachment & Anchoring 7. Platforms

More information

Exterior Elevated Elements Inspection Guidelines

Exterior Elevated Elements Inspection Guidelines Exterior Elevated Elements Inspection Guidelines Planning and Development 1. Guideline Purpose These guidelines are intended to assist practicing professionals in complying with Berkeley Municipal Code

More information

Appendix S Pump Station Evaluation

Appendix S Pump Station Evaluation Appendix S Pump Station Evaluation Technical Memorandum Date: October 12, 2001 To: Re: Orange County Utilities Task 6.4 Raw Wastewater Pump Stations 1.0 Summary In accordance with Task 6.4 of the Orange

More information

SECTION 22 LIGHTNING PROTECTION SYSTEM

SECTION 22 LIGHTNING PROTECTION SYSTEM SECTION 22 LIGHTNING PROTECTION SYSTEM 22.01 SCOPE: A. These Specifications shall form a part of the Contract Documents and shall govern construction work for all buildings to be built or modified for

More information

Utilizing Remaining Useful Life for Asset Management of Critical Wastewater Assets

Utilizing Remaining Useful Life for Asset Management of Critical Wastewater Assets *Jessica Brown, P.E., Freese and Nichols, Inc., (817) 312-6980; Jessica.Brown@freese.com Mazen Kawasmi, Freese and Nichols, Inc. ABSTRACT The City of Fort Worth s wastewater collection system includes

More information

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE 1.0 GENERAL 1.1 DESCRIPTION This section addresses the procedures to be employed for pipe bursting existing water/sewer pipelines, as identified on the drawings, and replacing with new Restrained Joint

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792

More information

CHAPTER 26 PLUMBING CODE

CHAPTER 26 PLUMBING CODE CHAPTER 26 PLUMBING CODE 26.01 PLUMBING CODE The Illinois Plumbing Code as promulgated by the Illinois Department of Public Health at 77 Illinois Administrative Code, Part 890, is hereby adopted as the

More information

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE 6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction

More information

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT Whisper Computer Solutions, Inc. P.O. Box 690502 San Antonio, TX 78269-0502 Phone: (210)681-6325 Fax: (210)681-6325 Email: support@whispersolutions.com PROPERTY INSPECTION REPORT Prepared For: Concerning:,

More information

FLORIDA RURAL WATER ASSOCIATION

FLORIDA RURAL WATER ASSOCIATION FLORIDA RURAL WATER ASSOCIATION 2970 Wellington Circle Tallahassee, FL 32309-6885 Telephone: 850-668-2746 ~ Fax: 850-893-4581 Storage Tank Operations & Maintenance Checklist Finished water storage is critical

More information

City of San Diego, CWP Guidelines

City of San Diego, CWP Guidelines PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

KWA Engineers, LLC Consulting Structural Engineers

KWA Engineers, LLC Consulting Structural Engineers KWA Engineers, LLC Consulting Structural Engineers October 14, 2014 Ms. Sylvia Dowling, President-Board of Directors Ms. Ray Stoudt, Maintenance Manager Aliki Condominium 2828 North Atlantic Avenue Daytona

More information

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs: RFQ number PR4877728 The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs: A- Supplying and installing 30 high wall A/C split unit 3HP- 24,000

More information

EVALUATION OF THE 5,000,000 GALLON STEEL STANDPIPE SOUTH STANDPIPE EVANSTON, ILLINOIS CITY OF EVANSTON EVANSTON, ILLINOIS

EVALUATION OF THE 5,000,000 GALLON STEEL STANDPIPE SOUTH STANDPIPE EVANSTON, ILLINOIS CITY OF EVANSTON EVANSTON, ILLINOIS EVALUATION OF THE 5,000,000 GALLON STEEL STANDPIPE SOUTH STANDPIPE EVANSTON, ILLINOIS FOR CITY OF EVANSTON EVANSTON, ILLINOIS April 10, 2014 5,000,000 Gallon Standpipe, South Standpipe Page 2 City of

More information

Structural Audit of Buildings

Structural Audit of Buildings International Journal of Civil Engineering Research. ISSN 2278-3652 Volume 5, Number 4 (2014), pp. 411-416 Research India Publications http://www.ripublication.com/ijcer.htm Structural Audit of Buildings

More information

Steve Brinkman Alain Pinel Realtors 167 S San Antonio Road Los Altos, CA 94022 RE: Foundation Inspection for 162 Del Monte Ave. Los Altos, CA 94022

Steve Brinkman Alain Pinel Realtors 167 S San Antonio Road Los Altos, CA 94022 RE: Foundation Inspection for 162 Del Monte Ave. Los Altos, CA 94022 M G C O N S T R U C T O R S & E N G I N E E R S, I N C. I N S P E C T O R S E N G I N E E R S B U I L D E R S C A L I F O R N I A E N G I N E E R I N G A N D B U I L D I N G L I C E N S E A / B 6 4 2 0

More information

Price List January 1, 2015

Price List January 1, 2015 Price List January 1, 2015 Cement Lined Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15

More information

Lighthouse Engineering, L.L.C.

Lighthouse Engineering, L.L.C. Wednesday, August 20, 2014 Lighthouse Engineering, L.L.C. Michael Gandy, P.E. Registered Professional Engineer (TX: 95672) Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website:

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

Self-Home Inspection Checklist

Self-Home Inspection Checklist To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional

More information

Evaluating the Condition of Seawalls/Bulkheads

Evaluating the Condition of Seawalls/Bulkheads Volume 2 Evaluating the Condition of Seawalls/Bulkheads By: Coastal Systems International, Inc. Typical bulkhead under construction Seawalls and bulkheads (walls) provide shoreline stabilization for many

More information

Guelph WWTP Digester No. 1 Inspection Report

Guelph WWTP Digester No. 1 Inspection Report Guelph WWTP Digester No. 1 Inspection Report PREPARED FOR: The City of Guelph- Revised and finalized by City of Guelph. DATE: February 15, 2011 Background In 2010 the City tendered a digester cleaning

More information

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General General All sanitary sewers, manholes and force mains shall be acceptance tested, as hereinafter specified in the presence of a City representative. Acceptance testing shall be performed after backfilling

More information

SECTION 724 PIPE CULVERTS

SECTION 724 PIPE CULVERTS SECTION 724 PIPE CULVERTS 724.1 Description. This work shall consist of providing pipe or pipe arch of the diameter or shape designated, laid upon a firm bed and backfilled as specified. Where appropriate

More information

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe 1. GENERAL The following supplemental sewer main specifications are intended to address the installation of high-density polyethylene

More information

Better Budgeting: Roof Management Plans Help Estimate Costs

Better Budgeting: Roof Management Plans Help Estimate Costs Better Budgeting: Roof Management Plans Help Estimate Costs Inside ASHE Summer 2015 Depending upon the complexity of a hospital roof, the average cost for a replacement roof can range from $15 to $40 per

More information

SECTION 02763 POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

SECTION 02763 POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe. SECTION 02763 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Repairs to existing sewer lines by replacing short lengths of failed pipe. 1.02 UNIT PRICES A. Measurement for point repairs is on a unit price

More information

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. POLYURETHANE COATING ON STEEL PIPE PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2 REFERENCE SPECIFICATIONS,

More information

SECTION 11014 WINDOW WASHING SYSTEMS

SECTION 11014 WINDOW WASHING SYSTEMS SECTION 11014 WINDOW WASHING SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes, but is not limited to, design and furnishing portable davits, davit sleeves, dvit bases, four (4) removable outriggers,

More information

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes)

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes) SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes) Maintenance Office Administrative Office Billing Office 530-426-7802 530-426-7800 916-332-4872

More information

AGENDA ITEM C9. COST/FUNDING SOURCE: $431,847.40/ Uniform Rate

AGENDA ITEM C9. COST/FUNDING SOURCE: $431,847.40/ Uniform Rate AGENDA ITEM C9 DATE: February 2, 2015 TO: FROM: SUBJECT: Matt Jordan, General Manager Charles Carden, Chief Operating Officer South Pasco Transmission Main Condition Assessment Services with Pure Technologies

More information

Mechanical Installation

Mechanical Installation Page -1-1. INTRODUCTION AND PURPOSE 1.1. This specification covers the installation, testing and precommissioning of mechanical equipment. Work is to be performed in conjunction with the manufacturer s

More information

Pressure Vessel Assessment Report

Pressure Vessel Assessment Report Project Information Client: Total Energy Location: Blackwell OK Date: 7/23/2013 Contact: Integrity Mgmt. Advisor: Chuck Easterbrooks - API 510 #2212 Cc: API / UT Inspector: Robert Van Pelt-API 510# 40899

More information

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION SPECIFICATION EO-5023 REVISION 3 MARCH 2003 REQUIREMENTS FOR

More information

Inspecting to a higher standard.

Inspecting to a higher standard. Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com

More information

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks Aboveground Storage Tanks Aboveground Storage Tank Inspection This Standard Operating Procedure describes the steps that campus units that manage aboveground oil storage tanks (ASTs) or containers must

More information

SECTION 02400 - STORM DRAIN SYSTEM

SECTION 02400 - STORM DRAIN SYSTEM SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And

More information

SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent

More information

ORDINANCE NO. 15 BE IT ORDAINED BY THE COUNCIL OF KANSAS CITY:

ORDINANCE NO. 15 BE IT ORDAINED BY THE COUNCIL OF KANSAS CITY: ORDINANCE NO. 15 Amending Chapter 60 of the Code of Ordinances of Kansas City, Missouri, entitled Sewers and Sewage Disposal by adding Sections 60-349 through 60-360; and establishing an effective date.

More information

PROTECTO 401 Price List

PROTECTO 401 Price List Price List January 1, 2015 Protecto 401 Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15

More information

Braselton Bros. Store Redevelopment 5134 HWY 53 BRASELTON, GA 30548 LEVEL 0 - DEMO & NEW PLAN. Room. Room. Room. Room. Room. Room. Room. Room.

Braselton Bros. Store Redevelopment 5134 HWY 53 BRASELTON, GA 30548 LEVEL 0 - DEMO & NEW PLAN. Room. Room. Room. Room. Room. Room. Room. Room. 1.d 2.d 3.d 4.d 1.d 2.d 3.d 4.d REMOVE, REPAIR, & REPLACE EXISTING STOREFRONT SYSTEMS D.1 D.2 REMOVE, REPAIR, & REPLACE EXISTING STOREFRONT SYSTEMS D.1 D.2 REMOVE STAIR & INFILL WALL C.1 REMOVE DOOR &

More information

Township of Enniskillen. Asset Management Plan

Township of Enniskillen. Asset Management Plan Township of Enniskillen Asset Management Plan 2014 1 TABLE OF CONTENTS Page A. Introduction 3 B. State of Local Infrastructure 4 C. Desired Levels of Service 7 D. Asset Management Strategy 8 E. Financing

More information

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work

More information

Water Quality Contingency Planning Standard EPB 540B

Water Quality Contingency Planning Standard EPB 540B Water Quality Contingency Planning Standard EPB 540B November 15, 2012 Water Quality Contingency Planning Standard The Water Quality Contingency Plan Standard is provided to aid waterworks owners and operators

More information

External Visual Inspection Form

External Visual Inspection Form Tank ID Code Part 1 (a): Information on Registered Facility Name of Registered Facility: Address: Town: Postal Code: Province: Phone Number: Person Conducting the Inspection: Transport Canada Facility

More information

Air Conditioning Systems Warranty Manual. Version 1.8

Air Conditioning Systems Warranty Manual. Version 1.8 Air Conditioning Systems Warranty Manual Version 1.8 1/2015 Air Conditioning System Warranty Contents Purpose 4 External Distribution... 4 Policies 5 Warranty Policy Overview... 5 Warranty Period... 5

More information

Calvert USA, Inc. Attic Stairs

Calvert USA, Inc. Attic Stairs Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,

More information

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

POLYURETHANE LINING AND COATING ON PIPE RAW WATER POLYURETHANE LINING AND COATING ON PIPE RAW WATER PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2

More information

Segreti Design Scope of Interior Design Services

Segreti Design Scope of Interior Design Services Segreti Design Scope of Interior Design Services Programming: During this phase, Segreti Design consults with the owner to develop the applicable requirements of the project and studies the feasibility

More information

Condition Assessment of a 48 PCCP Water Main Within an Abandon Subway Tunnel

Condition Assessment of a 48 PCCP Water Main Within an Abandon Subway Tunnel OAWWA 73 rd Annual Conference Condition Assessment of a 48 PCCP Water Main Within an Abandon Subway Tunnel By Jason DeLaet, P.E. Supervising Engineer Greater Cincinnati Water Works & Michael J. Livermore

More information

SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.

SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250. 02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily

More information

Photos showing the change in condition from 2006 to 2012 are located in Appendix A.

Photos showing the change in condition from 2006 to 2012 are located in Appendix A. January 27, 2012 Ms. Theresa Gallavan Economic Development Director City of Lompoc 100 Civic Center Plaza Lompoc, California 93436 RE: Lompoc Theater Limited Visual Condition Assessment Dear Theresa: Representatives

More information

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA STRUCTURAL ASSESSMENT FOR Full Metal Jacket Building 0 Prince Street, Prepared by: ALPHA CORPORATION (Alpha) 1850 S. Loudoun Street, Suite 200 Winchester, VA 22601 540-723-0704 September 22, 2010 J. Michael

More information

STANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS

STANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS STANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for providing metal fabricated items like castings, gratings, hatchways, ladders,

More information

Lighthouse Engineering, L.L.C.

Lighthouse Engineering, L.L.C. Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: Office@LighthouseEng.com Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering

More information

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary

More information

4 Steps for Quality Sewer Performance in Perpetuity

4 Steps for Quality Sewer Performance in Perpetuity 4 Steps for Quality Sewer Performance in Perpetuity By Gerhard Gerry P. Muenchmeyer, P. E. Principal Muenchmeyer Associates, LLC E-mail gerry@muenchmeyerassoc.com INTRODUCTION A well maintained and functional

More information

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth TABLE OF CONTENTS NO. MP-1 MP-2 MP-3 MP-4 MP-4.01 MP-4.02 MP-4.03 MP-5 MP-5.01 MP-5.02 MP-5.03 MP-5.04 MP-5.05 MP-5.06 MP-5.07 MP-5.08 MP-5.11 MP-5.12 MP-5.13 MP-5.14 MP-5.15 MP-5.16 MP-5.18 MP-5.19 MP-5.20

More information

PRE-PURCHASE INSPECTION REPORT

PRE-PURCHASE INSPECTION REPORT PRE-PURCHASE INSPECTION REPORT PREPARED FOR: PROPERTY ADDRESS: Waiheke Island DATE: 21 November 2012 Page 1 of 13 (a) This is a report of a visual only, non-invasive inspection of the areas of the building

More information

PRIVATE WELL SEPARATION

PRIVATE WELL SEPARATION PRIVATE WELL SEPARATION This is an explanation to explain what you have to do with your well, and/or the other sources of water that you may have, in order to receive public water. The term well includes

More information

T170 Interior Design Technology MTCU Code 61833 Program Learning Outcomes

T170 Interior Design Technology MTCU Code 61833 Program Learning Outcomes T170 Interior Design Technology MTCU Code 61833 Program Learning Outcomes Synopsis of the Vocational Learning Outcomes The graduate has reliably demonstrated the ability to 1. analyze a client's needs

More information

HomeSpec REPORT SUMMARY

HomeSpec REPORT SUMMARY HomeSpec 04/25/2007 Ms. Rachel Trujeque Re: 13038 West Plum Road Lot #1225 - Peoria, AZ. 85383 - Pre Drywall Inspection Dear Ms. Trujeque, At your request, a visual pre drywall inspection of the above

More information

WILDCAT CANYON ROAD SPECIFICATION NO. 16-11001 SLIDE REPAIR BIDDER'S PROPOSAL (continued)

WILDCAT CANYON ROAD SPECIFICATION NO. 16-11001 SLIDE REPAIR BIDDER'S PROPOSAL (continued) BIDDER'S PROPOSAL (continued) Item Estimated No. Description Quantity Unit Unit Cost Total Cost BASE BID 1 Traffic Control 1 LS $ $ 2 Construction Area Signs 1 LS $ $ 3 Excavation Safety 1 LS $ $ 4 Reset

More information

Assessing Curtain Walls

Assessing Curtain Walls Assessing Curtain Walls Considerations and Best Practices Paul E Beers GCI Consultants, LLC pbeers@gciconsultants.com What is a Curtain Wall System? A curtain wall system is an outer covering of a building

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

SECTION 09 97 00 WATER STORAGE TANK PAINTING

SECTION 09 97 00 WATER STORAGE TANK PAINTING SECTION 09 97 00 WATER STORAGE TANK PAINTING PART 1: GENERAL 1.01 SCOPE A. Section includes surface preparation, priming, and field coating for interior wet, interior dry, and exterior surfaces of steel

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

May 5, 2010. Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,

May 5, 2010. Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client, PROPERTY INSPECTION PROFESSIONALS May 5, 2010 Client Client Address Re: Inspection Address, Chicago, Illinois Dear Mr. Client, On May 4, 2010, Tomacor completed a property inspection of the above referenced

More information

Summit Anchor Company, Inc.

Summit Anchor Company, Inc. Summit Anchor Company, Inc. Safety From The Top Down Roof and Wall Safety/Tie-Back Anchors Suspended Access Systems and Fall Protection Overview National Safety Standards OSHA regulations specifically

More information

PENNSYLVANIA HOUSING FINANCE AGENCY (2015 UNDERWRITING APPLICATION) Tab 34 Physical/Capital Needs Assessment & Energy Audit

PENNSYLVANIA HOUSING FINANCE AGENCY (2015 UNDERWRITING APPLICATION) Tab 34 Physical/Capital Needs Assessment & Energy Audit Tab 34 Physical/Capital Needs Assessment & Energy Audit All Preservation developments must submit both of the following: A. Physical/Capital Needs Assessment A Physical/Capital Needs Assessment must be

More information

Prestressed Storage Tanks

Prestressed Storage Tanks Prestressed Storage Tanks Mike Harper Regional Manager mike.harper@dntanks.com / 714 767 1313 Kevin Peacock Regional Manager kevin.peacock@dntanks.com / 949 698 2740 DN Tanks overview Construction Procedures

More information

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems Page 1 of 5 Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems New Hampshire Department of Environmental Services

More information

ELIGIBLE REPAIR PROJECT PARAMETERS

ELIGIBLE REPAIR PROJECT PARAMETERS THE DISTRICT MUNICIPALITY OF MUSKOKA ONTARIO RENOVATES PROGRAM FOR HOMEOWNERS ELIGIBLE REPAIR PROJECT PARAMETERS 1. To have your project considered and payment processed, all projects requiring a Building

More information

SANITARY SEWER SPECIFICATIONS

SANITARY SEWER SPECIFICATIONS SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,

More information