Made possible by the 3 - modular concept: unlimited variety of switches

Size: px
Start display at page:

Download "Made possible by the 3 - modular concept: unlimited variety of switches"

Transcription

1 LEVEL SWITCHES

2 M O D U L E S 2 Made possible by the 3 - modular concept: unlimited variety of switches SWITCH MODULES switch elements, micro switches and proximity switches SPDT and 2xSPDT pneumatic with ON/OFF output pneumatic with proportional output aluminium and stainless steel housings high and low temperature versions IP 65 to IP 68 protection explosion proof versions self lifting clamps for safe connections FLANGE MODULES SS square flange, 92 mm pitch circle diameter (PCD) DIN, ANSI, BS and JIS industrial flanges special flanges with 98, 105 and 114 mm PCD special stainless steel flanges CS and stainless steel combination flanges Hastelloy special flanges DN 65 to 150, 3 to 6 PN 16 to 315, class 150 to 2500 flat seal, tongue and groove, ring joint etc. FLOAT MODULES fixed switching distance of 12 mm adjustable switching distance for pump control, vertical max mm, horizontal max. 557 mm Hastelloy and stainless steel floats floats according to NACE PP, PVDF and PTFE plastic floats stainless steel versions up to 350 bar operating pressure float modules for separation layer applications stainless steel floats with polyamide and halar coating

3 3 C O M B I N AT I O N S Customer specific solutions with money saving standard components SIDE MOUNT COMBINATIONS 01 with micro switches or proximity switches, also in explosion proof versions according to ATEX 02 pneumatic switching module with ON/OFF or proportional output with heat exchanger for very high or low operating temperatures 04 in IP 68 protection for submersion applications 05 for applications requiring explosion proof versions according to ATEX square standard flanges in stainless steel, 92 mm PCD 07 stainless steel and Hastelloy industrial flanges according to DIN, ANSI, BS and JIS 08 PP and PTFE industrial flanges according to DIN, ANSI, BS und JIS with fixed switching distance 10 with rod extension for longer switching distances 11 rod extension for switch point correction 12 with bellow for dirty media for pump control with adjustable switching distance 14 plastic versions for aggressive media 15 for separation layer surveillance of two media with varying gravity TOP MOUNT COMBINATIONS 14 15

4 A P P L I C AT I O N S A M P L E S 4 Alarm, measurement and control with Trimod Besta Switch-, flange- and float modules are selected according to the process parameters and the desired functions. This offers problem specific solutions using standard components and optimises the price/ performance ratio. max/min limits pneumatic control pump and valve control high alarm max pump off min pump on low alarm pump and valve control separation layer control external level control pump off pump on high / low alarm high / low alarm

5 5 H A N D L I N G Reliable, user friendly and easy to integrate Trimod Besta level switches feature a unique robustness. They are easily handled and quickly connected. Of course, the lid and screws can never be lost. FASTER AND EASIER CONNECTIONS The connection terminals have self lifting clamps. The optimized cable entry lets you connect the cables easily, quickly and in a professional manner. CONFORMITY AND EXCHANGEABILITY We offer our industrial and plastic ranges exclusively according to international DIN, ANSI, BS and JIS norms. The standard range is offered in the meanwhile world wide known square flange with 92 mm PCD. Because of that Besta switches can be mounted anywhere, anytime. 92 mm Ø 92 mm

6 S TA N D A R D S W I T C H E S 6 The Trimod Besta standard range: versatile, robust and economical Trimod Besta, the flexible one. It can be used anywhere, no matter where and when. Its versatility is unlimited, for highest temperatures, freezing cold, low density, vacuum or high pressure applications. THE MOST SUCCESSFUL SWITCHES Type A alarm, limit and control functions PN 25 according to DIN Operating temperature 0 to 300 C Ambient temperature 0 to 70 C Density of the liquid 0.7 kg/dm 3 Switching distance 12 mm, fixed Wetted materials stainless steel Switch module material seawater resistant die cast aluminium Flange square, 92 mm PCD Switching element SPDT micro switch Switching capacity 5 A / 250 VAC, 5 A / 30 VDC Protection IP 65 Installation depth (tank) 226 mm Similar Types Type A Type 5A Type 2A same as A , in addition, rod extensions G1, G2 and G3 can be used. for aggressive environments, housing exclusively made of stainless steel. with chromated switch housing Type A for low densities: 0.5 kg/dm 3

7 7 S TA N D A R D S W I T C H E S Type A to A with bellow for dirty media Type A bellow Perbunan operating temperature 0 to 120 C Type A bellow Silicon operating temperature 0 to 200 C Type A bellow Viton fluorelastomer operating temperature 10 to 200 C Type A bellow PTFE operating temperature 0 to 250 C Installation depth 253 mm other technical data same as A Similar Types Type A E15 special versions for waste water and waste tanks. Technical data similar to A FOR MANUALLY ADJUSTABLE SWITCHING DISTANCES Type A to A ideal for dual control, for example, pump control Type A adjustable switching distance Type A adjustable switching distance Typ A adjustable switching distance Typ A adjustable switching distance 37 to 218 mm 56 to 317 mm 83 to 442 mm 97 to 557 mm Installation depth 278 to 561 mm, depending on on type Density of liquid min. 0.8 kg/dm 3 other technical data same as A Viton is a registered trademark of DuPont Dow Elastomers

8 S TA N D A R D S W I T C H E S 8 PNEUMATIC SWITCHES AND CONTROLLERS Type P the pneumatic limit switch Function 3/2 way valve Regulating air max. 10 bar PN 25 according to DIN Operating temperature 1 to 250 C Ambient temperature 1 to 80 C Density of the liquid min. 0.7 kg/dm 3 Switching distance 12 mm, fixed Regulating ports G 1/8 (BSPP) IG Wetted materials stainless steel Switch module materials seawater resistant die cast aluminium Options Type 5P Type FP exclusively made of stainless steel with letter of conformity for use in explosion-proof areas Type M the pneumatic controller Function proportional controller Supply pressure 1.4 bar Output signal 0.2 to 1 bar PN 25 according to DIN Operating pressure 1 to 250 C Ambient temperature 1 to 80 C Density of the liquid min. 0.7 kg/dm 3 Control range without rod: 30 mm with rod: up to max. 230 mm Control ports G 1/8 (BSPP) IG Wetted materials stainless steel Switch module seawater resistant die cast aluminium Options Type 5M Type FM exclusively made of stainless steel with letter of conformity for use in explosion-proof areas

9 9 S TA N D A R D S W I T C H E S VERTICAL SWITCHES Type A und A for top mount installations Function dual point controller (pump) or single point actuator PN 16 according to DIN Operating temperature 0 to 300 C Ambient temperature 0 to 70 C Density of the liquid Pump control min kg/dm 3 Alarm min kg/dm 3 Switching distance A : 12 to 1340 mm A : 12 to 2840 mm Wetted materials stainless steel Switch module material seawater resistant die cast aluminium Flange dimensions 92 mm PCD Switching element SPDT micro switch Switching capacity 5 A / 250 VAC, 5 A / 30 VDC Protection IP 65 ACCESSORIES Type Type Type 2382 Counter flange for convenient mounting of level switches. Material: C22.8 The counter flange is welded directly onto the tank wall. Counter flange for convenient mounting of level switches. Material: SS The counter flange is welded directly onto the tank wall. Test actuator to simulate the switching function. Material: CrNi, O-ring: Viton The test actuator is mounted between the switch and the counter flange.

10 I N D U S T R I A L S W I T C H E S 10 The Trimod Besta industrial range for challenging applications The benefits of the wide spectrum of Trimod Besta switches are especially obvious in the industrial range. They are the best choice for high operating pressures, aggressive media and high process temperatures up to 400 C. A TYPICAL TRIMOD BESTA INDUSTRIAL SWITCH Type A 22C 04 alarm, limit and control functions PN 40 according to DIN Operating temperature 0 to 330 C Ambient temperature 0 to 70 C Density of the liquid min kg/dm 3 Switching distance 12 mm, fixed Wetted materials stainless steel Lose flange CS zinc galvanized, yellow passivated Switch module material seawater resistant die cast aluminium Flange DN 65, PN 40 according to DIN 2501 Flange facing raised face type C, DIN 2526 Switching element SPDT micro switch Switching capacity 5 A / 250 VAC, 5 A / 30 VDC Protection IP 65 Weight 5.4 kg Installation depth 226 mm

11 11 P L A S T I C S W I T C H E S The Trimod Besta plastic range for high aggressive media All wetted materials are made of high grade plastics such as PP, PTFE or PVDF. The limit switches are available with DIN, ANSI, BS and JIS industrial flanges. A TYPICAL TRIMOD BESTA PLASTIC SWITCH Type A PTFE switch, alarm, limit and control functions PN 10 according to DIN Operating temperature 0 to 200 C Ambient temperature 0 to 70 C Density of the liquid min. 0.8 kg/dm 3 Switching distance 12 mm, fixed Wetted materials PTFE with 25% glass fibre Lose flange CS zinc galvanized, yellow passivated Switch module material seawater resistant die cast aluminium Flange DN 80, PN 10 to DIN 2501 Flange facing raised face type C, DIN 2526 Switching element micro switch (SPDT) Switching capacity 5 A / 250 VAC, 5 A / 30 VDC Protection IP 65 Weight 5.4 kg Installation depth (tank) 235 mm

12 S H I P B U I L D I N G 12 Thousands of Trimod Besta switches ensure the safe voyage of vessels on our oceans Trimod Besta limit switches are successfully used in the ship building industry since They are installed in tankers, cruise ships, submarines, even in the fastest catamaran and the strongest crane ship in the world. THE FAVOURITES Type A The allrounder PN 25 according to DIN Operating temperature 0 to 300 C Ambient temperature 0 to 70 C Density of the liquid 0.7 kg/dm 3 Switching distance 12 mm, fixed Wetted materials stainless steel Switch module material seawater resistant die cast aluminium Flange square, 92 mm PCD Switching element SPDT micro switch Switching capacity 5 A / 250 VAC, 5 A / 30 VDC Protection IP 65 Installation depth (tank) 226 mm Type U3A Submersed type IP 68 PN 25 according to DIN Operating temperature -30 to +80 C Ambient temperature -30 to +80 C Protection IP 68, switch housing pressure tight up to 100 meters water column Cable length 3 m, or per request Cable type Neoprene (H07 RN-F) Other technical data same as A

13 13 R E G I S T R AT I O N S Marine approvals and registrations of Trimod Besta level switches Trimod Besta level switches come with the required shipping approvals and registrations. See our homepage for up to date listings. APPROVALS 1 American Bureau of Shipping, ABS 2 Bureau Veritas, BV 3 Det Norske Veritas, DNV 4 Germanischer Lloyd, GL 5 Lloyd s Register of Shipping, LRS 6 Registro Italiano Navale, RINA 7 Russian Maritime Register of Shipping, RMRS 8 China Classification Society, CSS Cat Link V, the 91 meter long catamaran of the Incat Ship Yard in Australia. Its transatlantic crossing at an average speed of knots set a new record. Trimod Besta level switches AA and AA are used to limit and control levels on board.

14 P L A N T M A N U F A C T U R I N G 14 Trimod Besta, whenever reliability is crucial Thanks to high functional safety and extreme longevity, Trimod Besta level switches are proven in petro-chemical plants and on offshore platforms. A TYPICAL INDUSTRIAL SWITCH FOR USE IN EXPLOSION PROOF AREAS Type ZK8 22C 041 pressure capsulated, alarm, limit and control functions Type of protection EEx ed IIC T6 EU approval PTB 03 ATEX 1006 PN 40 according to DIN Operating temperature -30 C to max. 145 C Ambient temperature according to EN Density of the liquid min. 0.7 kg/dm 3 Switching distance 12 mm, fixed Wetted materials stainless steel Lose flange CS zinc galvanized, yellow passivated Switch module material seawater resistant die cast aluminium Flange DN 65, PN 40 acc. to DIN 2501 Flange facing raised face type C, DIN 2626 Switching element SPDT micro switches Switching capacity 5 A / 220 VAC, 0.25 A / 250 VDC Protection IP 67 Registrations Trimod Besta level switches are registered world wide for diverse applications.

15 15 S E R V I C E S Trimod Besta limit switches in customized float chambers Besta has many years of experience concerning the use of limit switches in float chambers and containers. We offer the following approvals and services: Manufacturer Approvals Procedural Tests Welding Certificates DGR/PED Conformity WE DELIVER ACCURATE, TESTED AND PRE INSTALLED. A B C D E F G H DOCUMENTATION AND SERVICES Works certificates according to EN Test certificates according to EN B/3.1C Pressure test protocols Detailed documentation: parts information with technical specifications and material data, including lot and charge information Non-destructive testing: ultrasonic, x-ray and dye penetration testing Mechanical testing: tension, notch and hardness tests Base- and protective coatings

16 Besta Ltd. Ackerstrasse 45 CH-8610 Uster Switzerland Phone Fax Besta GmbH Im Vogelsgesang 4 D Frankfurt an Main Germany Phone Fax info@bestagmbh.de Limit switches with electric, electronic and pneumatic switch elements. Numerous ship building approvals and registrations. Homepage Find your local sales and service partner under Quality Management The Besta Ltd. quality management system according to ISO 9001 has been established in Opto-electronic level sensors for horizontal and vertical installation. Sensitivity adjustable via potentiometer. Registered Trade Marks Trimod and Besta are registered trade marks of Besta Ltd., Switzerland. Electronic limit switches for liquids and light weight solids, no calibration required. 2-wire electronic level transmitters with 4-20 ma output in 2-wire technology. With ATEX approval. Catalogue no. LTF01E/10.04 Technical specifications are for information only and may change without notice.

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Bypass level indicator With magnetic display Model BNA

Bypass level indicator With magnetic display Model BNA Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted

More information

Magnetic Float Switches For Liquid Level Alarm and Pump Control

Magnetic Float Switches For Liquid Level Alarm and Pump Control Product Data Sheet Horizontal Float Switches Magnetic Float Switches For Liquid Level Alarm and Pump Control Ideal for industrial applications such as pump control and high or low alarm duty on tanks and

More information

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve Order Code for VESTA Sterile Valves Type H_A 2/2 Way Seat Valve engineering for a better world GEA Mechanical Equipment VESTA Sterile Valves are designed for universal use in sterile process technology.

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

Customer environment. Customers

Customer environment. Customers Customer environment Customers GS-Hydro s non-welded piping systems are used in a number of applications in the offshore market. Drilling packages, ring lines, different types of cranes & winches are typical

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Colima Visco and Colima Viscorol Magnetic Level Indicators

Colima Visco and Colima Viscorol Magnetic Level Indicators 3.796.5275.200 IM-P329-02 CH Issue 1 Colima Visco and Colima Viscorol Magnetic Level Indicators Installation and Maintenance Instructions Colima Visco Colima Viscorol 1. Safety information 2. General product

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

Mobrey Magnetic Horizontal Float Switches

Mobrey Magnetic Horizontal Float Switches Product Data Sheet February 2015 IP101, Rev EC Mobrey Magnetic Horizontal Float Switches For Liquid Level Alarm and Pump Control Ideal for industrial applications such as pump control and high or low alarm

More information

COMBIMASS. Technical Data COMBIMASS eco-bio +

COMBIMASS. Technical Data COMBIMASS eco-bio + COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology Plastic Flow Meters for gases & liquids, using TROGAMID* & POYSUFONE Technology Applications Monitoring & Control of processes for: Water & Waste Water Treatment Chemical, Petrochemical & Paper Pharmaceutical,

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Type 3353 Angle Seat Valve

Type 3353 Angle Seat Valve Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat

More information

Micro Motion Model D and DL Coriolis Flow and Density Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,

More information

kymanual or Automatic - it s your Choice

kymanual or Automatic - it s your Choice . kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Variable V Area Flowmeter Rotameter The Original

Variable V Area Flowmeter Rotameter The Original Variable V Area Flowmeter Rotameter The Original 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com precise measurement of liquids

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Duplex Filters 40 FLDK 0008(C)-0120(C)

Duplex Filters 40 FLDK 0008(C)-0120(C) Industrial Filters Accumulators Duplex Filters 40 FLDK 0008(C)-0120(C) Filters for inline installation for continuous operating Ball valve change over Optimised flow characteristics by 3D computer aided

More information

OPTIMASS 6000 Technical Datasheet

OPTIMASS 6000 Technical Datasheet OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT

More information

Stainless steel process fittings

Stainless steel process fittings Page 1/6 Stainless steel process fittings Installation in pipe systems Installation in tanks and vessels Hygienic version FDA conformity of materials Probe length 120 mm 120 mm Availability of various

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

API Marine. BMS Presentation. Ballast Measurement Systems

API Marine. BMS Presentation. Ballast Measurement Systems API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter

More information

Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F. www.amot.com. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve High Pressure Control Valve Model 4418F Overview The 4418F has been designed specifically for use as an air start valve for diesel engines or as a fuel shut-off valve for gas turbine applications. Its

More information

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

HOPPER SHAPE KNIFE GATE VALVE

HOPPER SHAPE KNIFE GATE VALVE HOPPER SHAPE KNIFE GATE VALVE The model knife gate is a uni-directional wafer valve designed for industrial bulk handling service applications (powdered and granular products). The special design of the

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

VDL 53 - Vacuum drying oven for flammable solvents

VDL 53 - Vacuum drying oven for flammable solvents Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed

More information

OPTIMASS 1400 Technical Datasheet

OPTIMASS 1400 Technical Datasheet OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

DOUBLE GATE KNIFE GATE VALVE

DOUBLE GATE KNIFE GATE VALVE DOUBLE GATE KNIFE GATE VALVE The model knife gate is a bi-directional valve widely used in the Pulp and Paper industry (recycling or secondary fibre processing) designed to handle high concentrated or

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and

More information

Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve

Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications

More information

Viscotherm sensor electronic differential pressure transmitter electronic viscosity controller electric control valve power supply unit starter box

Viscotherm sensor electronic differential pressure transmitter electronic viscosity controller electric control valve power supply unit starter box Viscotherm P R O D U C T B U L L E T I N 772 Series V92 Model VC Electronic Component System Fig. 1, Viscotherm Viscotherm is a registered trade mark of VAF Instruments B.V. Introduction The benefits of

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Pressure controls, type KP

Pressure controls, type KP Introduction KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. KP pressure

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

T U R B I N E G A S M E T E R

T U R B I N E G A S M E T E R TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss

More information

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP Application Tight-closing butterfly valve for process engineering and industrial applications DN 50 to 300 NPS 2 to 12 Nominal pressure PN 10

More information

Vacuum Gate Valve DN 100 and DN 150

Vacuum Gate Valve DN 100 and DN 150 Vacuum Gate Valve DN 100 and DN 150 WER Dok.E.02.050_02.051 1. Introduction/Safety Instructions 2. Description 3. Technical Data 4. Installation 5. Operation 6. Maintenance Instructions 7. Spare Parts

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

Product catalogue, tank cleaning systems

Product catalogue, tank cleaning systems Product catalogue, tank cleaning systems Aquamat Tank cleaning units Aquarex Tank cleaning systems www.hammelmann.com Contents (Navigation via Bookmarks) Tank cleaning units L XL XXL High pressure lance

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

Engineered Solutions

Engineered Solutions Engineered Solutions Long established partnerships bring together the world s leading instrumentation companies within BKW. Our manufacturing facility enables us to quickly adapt standard instruments to

More information

NDP-50 Specifications

NDP-50 Specifications NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010 Overview are designed for measuring the flow of electrically conductive mediums. The full program consists of three different types of flowmeters making Siemens unique in that it covers all possible applications

More information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity

More information

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI) FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous

More information

Safety at a high level!

Safety at a high level! SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 viflow@viflow.fi www.viflow.fi

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½ to 12 Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Dimensions. LUC-M20 with F12 housing and process connection 2 approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions. Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning

More information

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD INGOLD Leading Process Analytics Retractable Housings InTrac Retractable Sensor Housings for Harsh Applications Wide Range of Options Intelligent Sensor Locking System Highly Efficient Sensor Cleaning

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a Application Tight-closing, double eccentric butterfly valve for process engineering and plants with industrial

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

The Unique Accelabar Flow Meter

The Unique Accelabar Flow Meter The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits Diesel Engine Air Intake Shutoff Valves Model RDS1 Swing Gate Valve Overview If flammable gas or vapor is present in the atmosphere surrounding a diesel engine, it can be ingested into the engine and become

More information

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Broad range of flow capacities 2% Full scale accuracy Versatile

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

Rosemount 1199 Submersible Seal

Rosemount 1199 Submersible Seal Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and

More information

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN 858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe

More information

Electromagnetic Flow Meter

Electromagnetic Flow Meter Electromagnetic Flow Meter Description The EL 2200 series of electromagnetic sensors represent the state of the art for the accurate measurement for water cycle and process applications. Flow meters are

More information

Via Stelvio, 355-21050 Marnate (VA), Italy Tel. +39.0331.600881 - Fax +39.0331.389144 E-mail: info@italcontrol.net - Website: www.italcontrol.

Via Stelvio, 355-21050 Marnate (VA), Italy Tel. +39.0331.600881 - Fax +39.0331.389144 E-mail: info@italcontrol.net - Website: www.italcontrol. [ Tauruslab.net ] Italcontrol srl Via Stelvio, 355-21050 Marnate (VA), Italy Tel. +39.0331.881 - Fax +39.0331.389144 E-mail: info@italcontrol.net - Website: www.italcontrol.net ...your gate to the world

More information

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side Proportional reducer D386 ATEX Classification according Article 3.3 of European Directive n 97/23/CE from 29/05/1997 Classification according group II, category 2 and temperature class T4 of ATEX Directive

More information