Rapid Set Point change feature RS 485 Communication Bumpless Auto-Manual transfer IP 54 Protection

Size: px
Start display at page:

Download "Rapid Set Point change feature RS 485 Communication Bumpless Auto-Manual transfer IP 54 Protection"

Transcription

1 PID Temper ature Controller Ser ies PR 69 Universal Input Configurable utput combination Configurable: Band, Deviation, Sensor break & Loop break alarms Single/Dual acting PID controllers with 5 Control modes Auto-tuning PID with provision for Soft-Start 6 Segment Ramp & Soak profile with Power Failure resumption modes Rapid Set Point change feature RS 485 Communication Bumpless Auto-Manual transfer IP 54 Protection Supply Variation Control Action Tuning Method Temperature sensors / Inputs Measurement Range Measurement Accuracy Resolution Configurable Set Points Display Keypad utput 1 utput 2 utput 3 Analog utput Update Rate Alarm Types Soft Start Feature Ramp Soak Feature perating Temperature Humidity (Non Condensing) Enclosure Dimensions (W x H x D) (in mm) 1A12B 1B12B 1C12B 1D12B VAC -20% to +10% (of ) 50/60 Hz N/FF (Symmetric / Asymmetric), PID (Single Acting) Auto Tuning / Manual Tuning Thermocouple: J, K, E, S, B, R; RTD: PT100-3 wire compensation; Analog Signal: (0-50 mv, 0-60 mv,12-60 mv) Sensor J: 0 to 700 C/32 to 1292 F, Sensor K: 0 to 1300 C/32 to 2372 F, Sensor E: 0 to 600 C/32 to 1112 F, Sensor R: 0 to 1750 C/32 to 32 F, Sensor S: 0 to 1750 C/32 to 32 F, Sensor B: 250 to 20 C/482 to 3308 F, Sensor PT100 3 wire: to 700 C/-328 to 1292 F ± 0.5% of full scale of PT100, ± 1% of full scale for TC & mv signals 0.1 C for RTD, J,E & 1 for S,B,K & C for mv signals 2 Dual 7 segment with LED indications, 4-digit process value, 4 digit set value 4-Keys: - Exit / Configurable Key, - Down, - Up, - Enter / Select 0 C to +50 C SSR: 12 VDC, 24 ma Short Circuit Protection -10 C to +60 C 80% (Rh) Flame Retardant UL94V0 48 x 48 x g Flush IP 65 (For Front Panel only) Analog: 0-10V / 4-20 ma Configurable Retransmission utput 0ms to 5s Absolute (High/Low/Band), Deviation (High/Low/Band), Sensor Break, Loop Break, Yes No Harmonic Current Emissions IEC Ed. 3.0 ( ) Class A ESD IEC Ed. 1.2 ( ) Level II Radiated Susceptibilty IEC Ed. 3.0 ( ) Level III Electrical Fast Transients IEC Ed. 2.0 ( ) Level IV Surges IEC Ed. 2.0 ( ) Level IV Conducted Susceptibilty IEC Ed. 2.2 ( ) Level III Voltage Dips & Interruptions (AC) IEC Ed. 2.0 ( ) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.0 ( ) Class A Radiated Emission CISPR 14-1 Ed. 5.0 ( ) Class B Cold Heat IEC Ed. 6.0 ( ) Dry Heat IEC Ed. 5.0 ( ) Vibration IEC Ed. 7.0 ( ) 5g Repetitive Shock IEC Ed. 4.0 ( ) 40g, 6ms Non-Repetitive Shock IEC Ed. 4.0 ( ) 30g, ms RDERING INFRMATIN Single Acting PID Controller 1A12B 2 Relays (SPST 8A & 5A, 240 VAC / 28 VDC), SSR driving output (12 VDC, 24mA) 1B12B 1 Relay (SPST 5A, 240 VAC / 28 VDC), Analog output (0-10V, 4-20mA), SSR driving output (12 VDC, 24mA) 1C12B 2 Relays (SPST 5A each,240v AC/28V DC), Analog output (0-10V, 4-20mA) 1D12B 3 Relays (SPST ne 8A & Two 5A, 240V AC / 28V DC)

2 PID Temper ature Controller Ser ies PR 69 Supply Variation Control Action Tuning Method Temperature sensors / Inputs Measurement Range Measurement Accuracy Resolution Configurable Set Points Display Keypad utput 1 utput 2 utput 3 Analog utput Update Rate Alarm Types Soft Start Feature Ramp Soak Feature RS 485 Communication Transmission Speed & Type Transmission Protocol perating Temperature Humidity (Non Condensing) Enclosure Dimensions (W x H x D) (in mm) 1A13B1 1B13B1 1C13B1 1D13B VAC -20% to +10% (of ) 50/60 Hz N/FF (Symmetric / Asymmetric), PID (Single / Dual Acting) Auto Tuning / Manual Tuning Thermocouple: J, K, E, S, B, R; RTD: PT100-3 wire compensation; Analog Signal: (0-50 mv, 0-60 mv,12-60 mv) Sensor J: 0 to 700 C/32 to 1292 F, Sensor K: 0 to 1300 C/32 to 2372 F, Sensor E: 0 to 600 C/32 to 1112 F, Sensor R: 0 to 1750 C/32 to 32 F, Sensor S: 0 to 1750 C/32 to 32 F, Sensor B: 250 to 20 C/482 to 3308 F, Sensor PT100 3 wire: to 700 C/-328 to 1292 F +/-0.5% of full scale of PT100, +/-1% of full scale for TC & mv signals 0.1 C for RTD, J,E & 1 for S,B,K & C for mv signals 4 Dual 7 segment with LED indications, 4-digit process value, 4 digit set value 4-Keys: - Exit / Configurable Key, - Down, - Up, - Enter / Select SSR: 12 VDC, 24 ma Short Circuit Protection Analog: 0-10V / 4-20 ma Configurable Retransmission utput 0ms to 5s Absolute (High/Low/Band), Deviation (High/Low/Band), Sensor Break, Loop Break, Yes 6 Segment Ramp Soak Profile RS 485 Communication 300 to BPS (Half Duplex) Modbus RTU 0 C to +50 C -10 C to +60 C 80% (Rh) Flame Retardant UL94V0 48 x 48 x g Flush IP 65 (For Front Panel only) Harmonic Current Emissions IEC Ed. 3.0 ( ) Class A ESD IEC Ed. 1.2 ( ) Level II Radiated Susceptibilty IEC Ed. 3.0 ( ) Level III Electrical Fast Transients IEC Ed. 2.0 ( ) Level IV Surges IEC Ed. 2.0 ( ) Level IV Conducted Susceptibilty IEC Ed. 2.2 ( ) Level III Voltage Dips & Interruptions (AC) IEC Ed. 2.0 ( ) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.0 ( ) Class A Radiated Emission CISPR 14-1 Ed. 5.0 ( ) Class B Cold Heat IEC Ed. 6.0 ( ) Dry Heat IEC Ed. 5.0 ( ) Vibration IEC Ed. 7.0 ( ) 5g Repetitive Shock IEC Ed. 4.0 ( ) 40g, 6ms Non-Repetitive Shock IEC Ed. 4.0 ( ) 30g, ms RDERING INFRMATIN Dual Acting PID Controller 1A13B1* 2 Relays (SPST 8A & 5A, 240 VAC / 28 VDC), SSR driving output (12 VDC, 24mA) 1B13B1* 1 Relay (SPST 5A, 240 VAC / 28 VDC), Analog output (0-10V, 4-20mA), SSR driving output (12 VDC, 24mA) 1C13B1* 2 Relays (SPST 5A each,240v AC/28V DC), Analog output (0-10V, 4-20mA) 1D13B1* 3 Relays (SPST ne 8A & Two 5A, 240V AC / 28V DC) *Note: With RS485 Modbus Communication

3 PID Temper ature Controller Ser ies PR 69 CNNECTIN DIAGRAM 1A12B 1B12B 1C12B 1D12B 1A13B1 1C13B1 1B13B1 1D13B1 TERMINAL TRQUE & CAPACITY Ø 3.5 mm Torque N.m (4.5 Lb.in) Terminal screw - M3 2 Solid Wire - 1 X mm AWG 1 X 26 to 14 MUNTING DIMENSIN (mm) GRID RING C/C C/C C/C

4 N-FF Temperature Controller Series PR 433 & PR 434 Highly Accurate Performance. Luxurious Single 3-digit LED Display. Wide supply range: vac (Un),-20 to +10% of Un. Front keypad with 4 keys. Thermocouple (J & K)/RTD 3-wire (Pt-100) sensor inputs. Control Modes: Proportional, N-FF Asymmetric, N-FF Symmetric. C & F temperature unit selectable Control utput: Relay & SSR Drive (Individual products) Supply Variation Control Action Power Consumption Temperature sensors / Inputs Measurement Range Measurement Accuracy Resolution Configurable Set Points Display Keypad utput 1 LED Indications: Error Indications perating Temperature Humidity (Non Condensing) Enclosure Dimensions (W x H x D) (in mm) RDERING INFRMATIN Single Acting PID Controller 1G11B VAC -20% to +10% (of ) 50/60 Hz N/FF (Symmetric / Asymmetric) & Proportional VAC Thermocouple: J, K ; RTD: PT100-3 wire compensation; ± 0.5% of full scale 1 C Fixed 1 7 segment, 3 digit LED display 4-Keys: - ESC, - Down, - Up, - Enter / Select Relay: (1 N) SPST 240 VAC / 30 VDC 0 C to +50 C -10 C to +60 C 80% (Rh) Flame Retardant UL 94 - V0 48 x 48 x g Flush IP 20 Terminal & Enclosure, IP 40 (For Front Panel only) 1H11B Sensor J: -5 C to 750 C / 23 F to 999 F, Sensor K: -20 C to 850 C / -4 F to 999 F, Sensor PT100 3 wire: C to 650 C / -148 F to 999 F Harmonic Current Emissions IEC Ed. 3.2 ( ) Class A ESD IEC Ed. 2.0 ( ) Level II Radiated Susceptibility IEC Ed. 3.2 ( ) Level III Electrical Fast Transients IEC Ed. 3.0 ( ) Level IV Surges IEC Ed. 2.0 ( ) Level IV Conducted Susceptibility IEC Ed. 3.0 ( ) Level III Voltage Dips & Interruptions (AC) IEC Ed. 2.0 ( ) All 7 Levels Conducted Emission CISPR 14-1 Ed. 5.2 ( ) Class A Radiated Emission CISPR 14-1 Ed. 5.2 ( ) Class B Cold Heat IEC Ed. 6.0 ( ) Dry Heat IEC Ed. 5.0 ( ) Vibration IEC Ed. 7.0 ( ) 5g Repetitive Shock IEC Ed. 4.0 ( ) 40g, 6ms Non-Repetitive Shock IEC Ed. 4.0 ( ) 30g, ms 1G11B 1H11B SBR VR UNR P1 (Red LED) F (Red LED) F (Red LED) SENSR PEN/BREAK ERRR VER RANGE ERRR UNDER RANGE ERRR Continuous N Continuous N Continuous FF Series PR-433, Relay utput (SPST 5A, 240 VAC / 30 VDC) Series PR-434, SSR driving output (12 VDC, 30 ma) SSR: 12 VDC, 30 ma Relay output N Display F value Display c value

5 N-FF Temperature Controller Series PR 433 & PR 434 CNNECTIN DIAGRAM 1G11B / 1G12B 1H11B / 1H12B (RELAY) (SSR) L N L N TERMINAL TRQUE & CAPACITY Ø 3.5 mm Torque N.m (4.5 Lb.in) Terminal screw - M3 2 Solid Wire - 1 X mm AWG 1 X 26 to 14 MUNTING DIMENSIN (mm) GRID RING C/C C/C C/C

6 Temperature Control Relay Wide ambient Temperature monitoring & controlling range with inbuilt temperature sensor. Protection Relay against variations of the ambient temperature set point (StH & StL) 3 digit LCD display for Real time Temperature Indication. User adjustable offset (-10 C to +10 C) LED indication for Relay Trip. Series nos. Number of set points Power Consumption (Max.) Device Characteristics Sensor Temperature Unit Display Resolution Accuracy utput Control Mode Hysteresis Temperature measurement and Controlling Range Set Point Range 41A111BR 41A111AR Low Level (StL) High Level (StH) ffset Minimum difference between StH & StL (for double SP only) TCR Double SP VAC, -20% to +10% 47Hz - 63Hz 3 VA TCR Single SP Digital IC Sensor C 0.1 C ± 3 C Max Relay N/FF 2 C (Fixed) -10 C to 55 C -5 C to 55 C -10 C to (StH-4 C) (StL + 4 C) to +55 C -10 C to 10 C Internally Fixed to 5 C 0 C to +55 C 4 C LED Indication Display Type Ratings N - Relay N condition (Red Color) Positive Image, Reflective, TN Terminal - Pole, Terminal NC, Terminal -N, 250V AC / 30 V DC (Res) perating Temperature Dimension (W x H x D) (in mm) - 10o C to +55o C - 20o C to +65o C X 85 X g DIN rail IP 20 for Terminals, IP 40 for Enclosure Harmonic Current Emissions ESD Radiated Susceptibility Electrical Fast Transients Surge Conducted Susceptibility Voltage Dips & Interruptions (AC) Conducted Emission Radiated Emission IEC IEC IEC IEC IEC IEC IEC CISPR 14-1 CISPR 14-1 Ed. 3.0 ( ) Class A Ed. 1.0 ( ) Level II Ed. 3.0 ( ) Level III Ed. 2.0 ( ) Level IV Ed. 2.0 ( ) Level IV Ed. 2.2 ( ) Level III Ed. 2.0 ( ) Ed. 5.0 ( ) Class B Ed. 5.0 ( ) Class B Cold Heat Dry Heat Vibration Repetitive Shock Non-Repetitive Shock IEC IEC IEC IEC IEC Ed. 6.0 ( ) Ed. 5.0 ( ) Ed. 7.0 ( ) 5g Ed. 4.0 ( ) 40g, 6ms Ed. 4.0 ( ) 40g, 6ms RDERING INFRMATIN 41A111AR 41A111BR VAC, Temperature Control Relay (TCR - 111) Double SP VAC, Temperature Control Relay (TCR - 112) Single SP

7 Temperature Control Relay FUNCTIN DIAGRAM Double SP - 41A111AR: Temperature Relay StH - Pole - NC - N Hysteresis StL Trip Power Supply (Relay FF) Relay - Normal - (Relay N) StH - SET HIGH TEMPERATURE PINT StL - SET LW TEMPERATURE PINT Single SP - 41A111BR: Temperature Relay StH - Pole - NC - N Hysteresis -5 C Trip Power Supply (Relay FF) (& LED FF) Relay - - Normal StH - SET HIGH TEMPERATURE PINT (Relay N) (& LED N) MUNTING DIMENSINS (mm) N SET A1 A TERMINAL TRQUE & CAPACITY CNNECTIN DIAGRAM SUPPLY CNNECTIN A1 110V-240VAC, -% & +10% SPDT Relay CNNECTIN A2 N-5A & NC-3A@ 250VAC/30VDC RESISTIVE

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog

More information

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Electronic Timer - Series Micon 175

Electronic Timer - Series Micon 175 Electronic imer - eries Micon 175 Compact 17.5mm Wide Integrated Dual Voltage Functions: ON Delay, tar Delta, One hot Wide ime ange: 0.3s - 30h LED Indications for Power and elay status Low Power Consumption

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

+ A + + - B V B - - + + + NO NC V COM - - - PV PV

+ A + + - B V B - - + + + NO NC V COM - - - PV PV + - A + B B - V + - NO NC COM + - + - V + - PV PV Ramp Soak 100 70 50 30 3 5 3 8 5 3 Minute Steam Heating Sensor Cooling Water PID Hotplate Specifications Input power supply AC 100 to 240V, 50/60Hz, DC

More information

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line BT. 2.9 M/E Process controller programmer /6 DIN - 48 x 48 mm gammadue series M line Advanced features, customizable and process adaptable High speed data aquisition and signal management. Efficent information

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

DC1010 - DC1020 - DC1030 - DC1040

DC1010 - DC1020 - DC1030 - DC1040 VEVIEW he DC1000 family of microprocessor based controllers combine a high degree of functionality and reliability at a very low price. Available in 4 different formats : 1/16 DIN, 1/8 DIN, 3/16 DIN, 1/4

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual Ⅰ. Warn Warning of connection Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual If the controller fails to operate or error occurs, the system will bring fault for it, please

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016) AUBER INSTRUMENTS Instruction Manual SYL-7 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 16) Caution This controller is intended to control equipment under normal operating conditions.

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips January 2014 Description The universal CPA PC-Programmable Alarms provide on/off control, warn of unwanted process conditions, and provide emergency shutdown. Very economical, they accept a direct signal

More information

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards.

The E5CN provides communications or event input functionality when mounted with one of the following Option Boards. Digital Temperature Controller Compact and Intelligent Temperature Controller Auto-tuning and self-tuning available. Can auto-tune even during execution of self-tuning Heating or heating/cooling control

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

User Manual Auto Tuning PID Temperature Controller

User Manual Auto Tuning PID Temperature Controller User Manual Auto Tuning PID Temperature Controller TUPC-T series (Applicable for accurate controls of Temperature) TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097

More information

PIEZOMETER AIRFLOW MEASURING RING

PIEZOMETER AIRFLOW MEASURING RING PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

IMR 6000/10../20../30

IMR 6000/10../20../30 IMR 6000/10../20../30 System frame Component of the MMS 6000 Machine Monitoring System Applications: Slots for adaptation of the signal processing periphery (monitors, logic cards and interface cards)

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product

More information

Signal converters Index

Signal converters Index Signal converters Index Power supplies 2 - Signal converters Signal converters... 2. 2.24 Selection Accessories, CC-U...2.7 Analog signal converters, CC-E/STD & CC-E x/x...2.3 Analog standard signal converter,

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information