Architectural Accessory Details

Size: px
Start display at page:

Download "Architectural Accessory Details"

Transcription

1 Architectural Accessory Details February, 2014 Contents Construction Details 1 Wood Moulding 2 Louver Unites - Wood and Metal 4 Vision Panels - Wood and Metal 5 Factory Installed Glass 6 Astragals/Edges 9 Dutch Door Door with Transoms Wicket Door 22 Special machining - Rabbiets/Radius Edge 23 Fire Door Plant-Ons 24 Full Glass / Full Warranty Door 26 ElectroLynx 27

2 1 Construction Details October, 2013 Meeting Edge Options General Moulding Requirements Species shall match or be compatible with face veneer or laminate No Bevel Bevel Flat Astragal Specify transparent or opaque finish. Moulding shall be free of open defects, shake, splits, or doze Rabbeted Parallel Bevel Dbl. Egress Metal Edge Guards/Astragal Metal Edge Guards Moulding must be smooth and free of visibale knife, saw or sanding marks Specify from the options on the left: Glazing Options Graham Standard Minimums Flush Mouldings All cutouts for metal or wood vision panels must be a minimum of 5 (152 mm) from the edge of the door and/or other cutouts for louvers, locks, closers or other hardware. This 5 (152 mm) distance must be maintained or the fire label and warranty will be voided. For non-fire rated doors, the distance may be decreased to 5 (127 mm). Less than 5 (127 mm) may affect the warranty Metal Vision Frame Lip Moulding Using a 10 (254 mm) margin between the edge of the door and the edge of any cutout near the lock area will eliminate most label and warranty conflicts.

3 2 Wood Mouldings Lip Moulding for Lites Matching specie to door face veneer for Premium grade. For use with 1-3/4 thick doors M2G - Flat Lip Moulding 15/16 wide x 5/8 thick, 3/32 radius. M3G - Beveled Lip Moulding 15/16 wide x 3/8 thick, 3/32 radius 2. Wire Brad - Lip Moulding is factory attached. 3. 1/4 Glazing - Glazing materials are not included. 4. Beveled back for glazing compound or 1/16 tape (not included). 5. Lites - Order size - visible glass size Cutout size = visible glass + (2 x moulding profile) Glass size = cutout - 1/4 wide - 1/4 high 4 3/32 15/16 3/32 15/16 3/8 5/8 3/8 5/8 11/16 11/16 M2G M3G Flush Moulding for Lites Matching specie to door face veneer for Premium grade. For use with 1-3/4 thick doors M6G - Flush Moulding 11/16 wide x 3/8 thick, 3/32 radius. 2. Wire Brad - Flush Moulding is factory attached. 3. 1/4 Glazing - Glazing materials are not included. 4. Beveled back for glazing compound or 1/16 tape (not included). 5. Lites - Order size - visible glass size Cutout size = visible glass + (2 x moulding profile) Glass size = cutout - 1/4 wide - 1/4 high 4 3/32 3/8 11/16 M6G

4 3 Wood Mouldings August, 2011 Fire Rated Flush Wood Moulding for Lites 1. Available with 45, 60 and 90 minute fire rated (mineral core) doors. 2. Factory installed: glass, glazing material, glazing bead, clips, nails, provided. 3. Flush Moulding Profile: MF3 4. Available Species: Red Oak, Natural Birch, White Maple, Cherry, Mahogany, and Walnut. Contact you Customer Service Professional for availability of other species. 5. Glass: 1/4 thick nominal wired glass or 3/16 thick nominal ceramic 6. Cutout Size and Glass Size: (100 in 2 maximum) Cutout Width = Visible Glass Width Cutout Height = Visible Glass Height Glass Width = Visible Glass Width Glass Height = Visible Glass Height /4 MF3

5 4 Louver Units 1 1/2 3 V-Slat Wood Louver 1. L100 Wood Non-Vision Louver Unit - 3/4 wide, 33% free air movement. Matching specie to door face veneer for Premium grade. For use with 1-3/4 thick doors. Specify louver size the same as cutout size. 1-3/8 thick doors require framed louvers. Louvers may not be installed in 20 minute fire doors. M2W - Flat Lip Moulding 11/16 wide x 5/8 thick, 3/32 radius. M6W - Flush Moulding 7/16 wide x 3/8 thick, 3/32 radius 2. Wire Brad - Mouldings are factory attached. Louvers are not factory installed as standard. Louvers may be facorty installed as an option. 3. Field installation may require the use of glazing tape for proper fit. 2 3/4 11/16 3/32 3/32 5/8 3/8 7/16 7/16 1 1/2 3 M2W V-Slat Metal Louver M6 W 1. L600 Metal Non-Vision Louver Unit - 1-1/16 wide, 20 gauge steel, 50% free air movement. For use with 1-3/4 thick doors. 1-3/8 thick doors require framed louvers. Louver cutout is 1/8 less then order size. Louvers may not be installed in 20 minute fire doors. M2M - Flat Lip Moulding 9/16 wide x 5/8 thick, 3/32 radius. M6M - Flush Moulding 5/16 wide x 3/8 thick, 3/32 radius 2. Wire Brad - Mouldings are factory attached. Louvers are not factory installed. Louvers may be facorty installed as an option. 3. Field installation may require the use of glazing tape for proper fit. 2 1/16 9/16 3/32 3/32 5/8 3/ /16 M2M Metal Fusible Link Louver 1. L1900A Framed Metal Non-Vision Louver Unit - Fire rated fusible link unit for use with 45, 60 or 90 minute fire doors. 1-3/4 wide. 135 degree F fusible link. 40% free air movement. For use with 1-3/4 thick doors only. Not factory installed. Louvers may not be installed in 20 minute fire doors. 2. Stell mounting frame overlaps door face Through bolt applied. Security screws are available by option. 4. Metal fusible link louvers will not be factory installed. 5/16 M6M 2

6 5 Vision Panels Fire rated Metal Vision Panel M110 Metal Vision Frame - Fire rated for 20, 45, 60 and 90 minute fire door applications. 18 gauge steel with mitered, round corners that are braced and welded. Available wood veneer wrapped as an option. Low profile for hardware clearance. 2. Metal frame and glazing support clip. 3. Vandal proof binder screw. 4. For 1/4 thick listed glazing (not included). Note: No glazing compound or tape is required. Not factory installed. 5. Fire rated metal vision panels will be factory installed. 6. Lites - Order size = visible glass size Cutout size = visible glass size + 1-1/2 side + 1-1/2 high Glass size = visible glass size + 3/4 wide + 3/4 high 7. Listed for UL10b and UL10c. Note: Custom shapes for specialty lites must be specified for visible glass size and cutout size Minute Moulding for Lites 1. Matching specie to door face veneer for Premium grade. For use with 1-3/4 thick 20 minute rated fire doors. M2L - Beveled Lip Moulding 1 wide x 3/4 thick. M2F - Beveled Flush Moulding 3/4 wide x 1/2 thick. 2. Metal glazing support clip. 3. Glazing compound or tape required for proper fit (not included). 4. For 1/4 thick listed glazing (not included). Size are visible glass size. Cutouts are 1 larger in width and height. Custom shapes for specialty lites must be specified for visible glass size and cutout size. 5. Lites - Order size = visible glass size Cutout size = visible glass size + (2 x moulding profile) Glass size = cutout - 1/4 wide - 1/4 high 6. Listed for UL10b and UL10c. 4 Note: Custom shapes for specialty lites must be specified for visible glass size and cutout size. 11/16 1/2 9/32 1/2 1/ M2F M2L

7 6 Factory Installed Glass April, 2013 PYRAN PLATINUM F (FIG03) Glass Description CERAMIC, FILMED FIRE AND SAFETY RATED GLASS BRAND: PYRAN PLATINUM F GRADE: PREMIUM THICKNESS: 3/16 NOMINAL WARRANTY: 3 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II FIRE LISTINGS UL AND INTERTEK/WARNOCK- HERSEY APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION AND 2406 NOTES RATING EXPOSED AREA WIDTH HEIGHT 20, , CORE TYPE Mineral, Particleboard, Stave Lumber, Engineered Composite, Agrifiber Mineral, Particleboard, Stave Lumber, Engineered Composite 2 60* Mineral 2 60* Mineral 2 60, Mineral Temp Rise Mineral * 2 lites max 1 Same as above PEMKO FG Same as above PEMKO FG PYRAN PLATINUM L (FIG04) Glass Description CERAMIC, LAMINATED FIRE AND SAFETY RATED GLASS BRAND: PYRAN PLATINUM L GRADE: PREMIUM THICKNESS: 3/8 NOMINAL WARRANTY: 5 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II FIRE LISTINGS UL AND INTERTEK/WARNOCK- HERSEY APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION AND 2406 NOTES RATING EXPOSED AREA WIDTH HEIGHT 20, , CORE TYPE Mineral, Particleboard, Stave Lumber, Engineered Composite, Agrifiber Mineral, Particleboard, Stave Lumber, Engineered Composite 2 60* Mineral 2 60* Mineral 2 60, Mineral Temp Rise Mineral * 2 lites max 1 Same as above PEMKO FG Same as above PEMKO FG

8 7 Factory Installed Glass April, 2013 FIRELITE NT (FIG05) Glass Description CERAMIC, FILMED FIRE AND SAFETY RATED GLASS BRAND: FIRELITE NT GRADE: PREMIUM THICKNESS: 3/16 NOMINAL WARRANTY: 3 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II FIRE LISTINGS UL APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION AND 2406 NOTES RATING EXPOSED AREA WIDTH HEIGHT 20, , CORE TYPE Mineral, Particleboard, Stave Lumber, Engineered Composite, Agrifiber Mineral, Particleboard, Stave Lumber, Engineered Composite 2 60* Mineral 2 60* Mineral 2 60, Mineral Temp Rise Mineral * 2 lites max 1 Same as above PEMKO FG Same as above PEMKO FG FIRELITE PLUS (FIG06) Glass Description CERAMIC, LAMINATED FIRE AND SAFETY RATED GLASS BRAND: FIRELITE PLUS GRADE: PREMIUM THICKNESS: 5/16 NOMINAL WARRANTY: 5 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II FIRE LISTINGS UL APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION AND 2406 NOTES RATING EXPOSED AREA WIDTH HEIGHT 20, , CORE TYPE Mineral, Particleboard, Stave Lumber, Engineered Composite, Agrifiber Mineral, Particleboard, Stave Lumber, Engineered Composite 2 60* Mineral 2 60* Mineral 2 60, Mineral Temp Rise Mineral * 2 lites max 1 Same as above PEMKO FG Same as above PEMKO FG

9 8 Factory Installed Glass December, /4 TEMPERED (FIG01) Glass Description 1/4 CLEAR TEMPERED IMPACT SAFETY RATED GLASS QUALITY RATING: Q3, ASTM C THICKNESS: 1/4 NOMINAL WARRANTY: 1 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION 2406 NOT FOR USE ON FIRE RATED DOORS 1/4 FILMED WIRE (FIG02) Glass Description 1/4 FILM WIRE, FIRE AND IMPACT SAFETY RATED GLASS QUALITY RATING: Q3, ASTM C THICKNESS: 1/4 NOMINAL WARRANTY: 1 YEAR LIMITED INCLUDES: GLAZING TAPE AND SETTING BLOCKS AS REQUIRED IMPACT SAFETY RATING: CPSC 16CFR1201, CAT I AND CAT II FIRE LISTINGS UL AND INTERTEK/WARNOCK- HERSEY APPROVED, POSITIVE PRESSURE. GLASS IS MARKED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE SECTION AND 2406 RATING EXPOSED AREA WIDTH HEIGHT 20, CORE TYPE Mineral, Particleboard, Stave Lumber, Engineered Composite, Agrifiber 60, 90 * Mineral Temp Rise Mineral * Non Temp Rise

10 9 Astragals/Edges Flat Wood Astragal 1. A1 Wood Astragal - 2 wide, 1/2 thick, 1/4 radius on face edges. Matching specie to door face veneer for Premium grade. For use with 1-3/4 or 1-3/8 thick doors. 2. May be applied using wood screws and adhesive. 3. Not for use on any 45, 60 or 90 minute fire rated doors. Flat wood astragals may be applied to 20 minute neutral pressure tested pairs with Firestop metting edges. 1 3 Metal Astragal & Edge 1. M207. metal Edge Set With Overlapping Astragal - 16 gauge welded astragal overlaps meeting edge 1. Approved for 20, 45, 60 and 90 minute fire door applications. Available wood veneer wrapped as an option. May be specified unmachined or machined for builders hardware gauge wrap-around metal edge overpals meeting stile Phillips Flat head Screws - #8 x 3/4 12 on center (included). Note: Overlapping astragals are no longer required for fire rated pairs Double Metal Edge 1. M208 Double Metal Edge Set - 20 gauge wrap-around metal edge overlaps metting stiles of doors 1. Approved for 20, 45, 60 and 90 minute fire door applications. Available wood veneer wrapped as an option. may be specified unmachined or machined for builders hardware. 2. Phillips Flat head Screws - #8 x 3/4, 12 on center (included). Note: Double metal edges are no longer required on 20, 45, 60 or 90 minute paris if doors are specified to be without metal edges. Requires special interior blocking profiles. 3. Also available with 5 wrap-around metal edges for use with the application of concealed vertical rod exit devices in the M250 series.

11 10 Dutch Door (Non Fire Rated) Height By Specification General Notes 1. Allow for shelf thickness when specifying hardware. 2. Standard shelf is (28 mm) thick wood, 1 side only. 3. Standard wood shelf sits between leaves. 4. Shelf and supports are not factory installed 5. Note if shelf is not required. 6. Note if other than standard shelf is required. 7. Dutch doors are available in GPD or GCD bonded consturction only. 8. GPD has matching bottom rail in top leaf. GCD has non-matching bottom rail in top leaf. 9. Dutch doors are available in single openings up to 4 0 x 8 0. Dutch doors are available in paired openings up to 8 0 x /8 Height By Specification (includes shelf) 8 1-3/4 Shelf 4 1-1/8 4 Shelf Bracket

12 11 Dutch Door (Non Fire Rated) NON RATED DUTCH DOOR TOP LEAF 2 Wood Rails (Min.) 1-1/8 Wood Shelf 2 Wood Rails (Min.) General Notes 1. Dutch doors may be provided with: a. Straight cut metting edges of top and bottom leaf. b. Rabbeted metting edges of top and bottom leaf. 2. Standard clearnace between top leaf and bottom leaf of Dutch doors is 3/ Dutch door latching may be cylindrical, mortise or flushbolt latches that latch: a. top leaf into bottom leaf, bottom leaf into frame. b. top leaf into bottom leaf, top leaf into frame. c. top leaf into frame, bottom leaf into frame. BOTTOM LEAF EXAMPLE OF LATCHING CONFIGURATION TOP LEAF TOP LEAF ACTIVE LEAF INACTIVE LEAF BOTTOM LEAF BOTTOM LEAF PAIR OF DUTCH DOORS

13 12 Dutch Door (20 Minute Fire Rated) Height By Specification 1/8 General Notes 1. Allow for shelf thickness when specifying hardware. 2. Standard shelf is (28 mm) thick wood, 1 side only. 3. Standard wood shelf sits between leaves. 4. Shelf and supports are not factory installed 5. Note if shelf is not required. 6. Note if other than standard shelf is required. 7. Dutch doors are available in GPD or GCD bonded consturction only. 8. GPD has Firestop bottom rail in top leaf. Firestop top rail in bottom leaf. GCD has Firestop bottom rail in top leaf, Firestop top rail in bottom leaf. 9. Dutch doors are not available in 90 minute neutral pressure tested construction. 10. Positive pressure fire tested Dutch door constructions are not available. 11. Dutch doors are available in 20 minute fire rated single openings up to 4 0 x Dutch doors are available in 20 minute fire rated paired openings up to 8 0 x 8 0. Height By Specification (includes shelf) 8 1-3/4 Shelf 1-1/8 4 4 Shelf Bracket

14 13 Dutch Door (20 Minute Fire Rated) 20 MINUTE DUTCH DOOR TOP LEAF 2 wide Firestop Rails (Min.) Intumescent 1-1/8 Wood Shelf 2 wide Firestop Rails (Min.) BOTTOM LEAF General Notes minute Dutch doors may be provided with one of these: a. An overlapping astragal applied to the bottom rail of the top leaf b. Intumescent fire seal installed in the bottom rail of the top leaf. c. Standard wood shelf sits between leaves. 2. A maximum 1/8 (3.2 mm) clearance between top leaf and bottom leaf of fire rated Dutch doors is allowed. 3. Fire rated Dutch doors require both leaves to be self latching. Leaf to leaf or leaf to frame. 4. Fire rated Dutch door latching is limited to cylindrical or mortise latches that latch: a. top leaf into bottom leaf, bottom leaf into frame. b. top leaf into bottom leaf, top leaf into frame. c. top leaf into frame, bottom leaf into frame. 5. Flushbolts are allowed on the inactive leaves of a pair. EXAMPLE OF LATCHING CONFIGURATION TOP LEAF TOP LEAF ACTIVE LEAF INACTIVE LEAF BOTTOM LEAF BOTTOM LEAF PAIR OF DUTCH DOORS

15 14 Dutch Door (45/60 Minute Fire Rated) Height By Specification 1/8 General Notes 1. Allow for shelf thickness when specifying hardware. 2. Standard shelf is (28 mm) thick wood, 1 side only. 3. Standard wood shelf butts to face of bottom leaf. 4. Shelf and supports are not factory installed 5. Note if shelf is not required. 6. Note if other than standard shelf is required. 7. Dutch doors are available in GPD or GCD bonded consturction only. 8. GPD has Firestop bottom rail in top leaf. Firestop top rail in bottom leaf. GCD has Firestop bottom rail in top leaf, Firestop top rail in bottom leaf. 9. Dutch doors are not available in 90 minute neutral pressure tested construction. 10. Positive pressure fire tested Dutch door constructions are not available. 11. Dutch doors are available in 45/60 minute fire rated single openings up to 4 0 x Dutch doors are not available in 45/60 minute fire rated paired openings. Height By Specification (includes shelf) 8 1-3/4 Shelf 1-1/8 4 4 Shelf Bracket

16 15 Dutch Door (45/60 Minute Fire Rated) 45/60 MINUTE DUTCH DOOR TOP LEAF 2 wide Firestop Rails (Min.) Intumescent 1-1/8 Wood Shelf 2 wide Firestop Rails (Min.) BOTTOM LEAF General Notes 1. 45/60 minute Dutch doors may be provided with one of these: a. An overlapping astragal applied to the bottom rail of the top leaf b. Intumescent fire seal installed in the bottom rail of the top leaf. c. Standard wood shelf sits between leaves. 2. A maximum 1/8 (3.2 mm) clearance between top leaf and bottom leaf of fire rated Dutch doors is allowed. 3. Fire rated Dutch doors require both leaves to be self latching. Leaf to leaf or leaf to frame. 4. Fire rated Dutch door latching is limited to cylindrical or mortise latches that latch: a. top leaf into bottom leaf, bottom leaf into frame. b. top leaf into bottom leaf, top leaf into frame. c. top leaf into frame, bottom leaf into frame. EXAMPLE OF LATCHING CONFIGURATION TOP LEAF TOP LEAF BOTTOM LEAF BOTTOM LEAF

17 16 Door with Transoms (Non Fire Rated) Non-rated Doors with Transoms 1. Doors with transoms are available with or without frame transom bars in single or paired openings. 2. Meeting edges of transoms and doors in openings without transom bars may be straight cut or rabbeted. See standard rabbet detail. 3. Doors with transoms are available in GPD and GCD bonded constructions only. 4. GPD has matching rails at bottom of transom and top of door. GCD has nonmatching rails at bottom of transom and top of door. 5. Spring bolts are required for installation of transom panels. Springbolts must be placed a minimum of 2 (51 mm) from each corner. Panels up to 18 (458 mm) in height require 2 springbolts per side. Panels up to 36 (916 mm) in height require 3 springbolts per side. Panels up to 40 (1220 mm) in height require 4 springbolts per side. 6. Doors with transoms are available in single openings up to 4 0 x Maximum transom panel size in a single opening up to 4 0 wide x 3 4 high. Doors with transoms are available in paired openings up to 8 0 x Maximum transom panel size is a paired opening is 8 0 wide x 3 4 high.

18 17 Doors with Tramsoms (Non-Rated) NON RATED DOOR WITH TRANSOM Solid Wood Cores Transom 2 Wood Rails 1/8 Max. Gap 2 Wood Rails 1/8 Max. Gap Steel Astragals Solid Wood Cores 1-3/4 1-3/4 DOOR WITH TRANSOM IN FRAME WITH MULLION Non-Rated Doors with Transoms Transom 2 Wood Rails Mullion 1. Doors with transom may be provided with: a. Straight cut meeting edges of door and transom with an over lapping astragal. b. Straight cut meeting edges of door and transom with frame transom bar. c. Rabbeted meeting edges of door and transom. 2. A maximum 1/8 (3.2 mm) clearance between door and transom is allowed in non-rabbeted applications. 3. Transom panels must be installed using springbolts placed a minimum of 2 (51 mm) from each corner. 2 Wood Rails

19 18 Door with Transoms (20 Minute Fire Rated) 20 Minute Fire Rated Doors with Transoms 1. Transom panels must be the same construction as the 20 minute fire door. 2. Neutral pressure tested doors with transom panels may be rabbeted, or installed with a metal edge and astragal, or with a transom bar between the door and transom. Positive pressure tested doors with transom panels must be installed in a frame with a transom bar between the door and transom. 3. Transom installed over a pair of 20 minute rated doors must be separated with a frame mullion. The mullion must limit the width of each separate transom to the width of each leaf of the door pair. 4. The transom panel must be machined for spring bolts by the licensed machiner of manufacturer. The appropriate number of springbolts will be supplied by the machiner. 5. Fire rating labels will be provided on door and transom stating Door and Transom Assembly. 6. Fire rated transom panels must be installed using approved steel springbolts. The springbolts shall be placed 2 (51 mm) from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the springbolts. Hole locations vary with respect to rabbeted and unrabbeted tansoms. Panels up to 18 (458 mm) in height require 2 springbolts per side. Panels up to 36 (916 mm) in height require 3 springbolts per side. Panels up to 40 (1220 mm) in height require 4 springbolts per side. 7. Maximum clearance between the frame and panel must be 1/8 (3.2 mm). 8. Doors with transoms are available in single openings up to 4 0 x Maximum transom panel size in a single opening up to 4 0 wide x 3 4 high. Doors with transoms are available in paired openings up to 8 0 x Maximum transom panel size is a paired opening is 8 0 wide x 3 4 high. Transom panels above pairs of doors must be separated by a mullion.

20 19 Doors with Tramsoms (20 Minute Fire Rated) 20 MINUTE DOOR WITH TRANSOM Solid Wood Cores Transom 1/8 Max. Gap 1 Wide Firestop Rails Min. 1 Wide Firestop Rails Min. 1/8 Max. Gap Steel Astragals Solid Wood Cores 1-3/4 20 MINUTE DOOR WITH TRANSOM IN FRAME WITH MULLION Transom 1 Wide Firestop Rails Min. Mullion 1 Wide Firestop Rails Min. 1-3/4 20 Minute Doors with Transoms 1. Neutral pressure tested fire doors with transoms may be provided with: a. Straight cut meeting edges of door and transom with an over lapping astragal. b. Straight cut metting edges of door and transom with frame transom bar. c. Rabbeted meeting edges of door and transom. Positive pressure tesed fire doors with transoms must be installed in a frame with transom bar between the door and transom. 2. A maximum 1/8 (3.2 mm) clearance between door and transom is allowed in non-rabbeted applications. Maximum clearance between the frame and transom panel must be 1/8 (3.2 mm). 3. Fire rated Transom panels must be installed using approved steel springbolts. The springbolts shall be placed 2 (51 mm) from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the springbolts. Hole locations vary with respect to rabbeted and unrabbeted transoms. Panels up to 18 (458 mm) in height require 2 springbolts per side. Panels up to 36 (916 mm) in height require 3 springbolts per side. Panels up to 40 (1220 mm) in height require 4 springbolts per side.

21 20 Door with Transoms (20 Minute Fire Rated) 45/60/90 Minute Fire Rated Doors with Transoms 1. Transom panels must be the same construction as the 20 minute fire door. 2. Neutral pressure tested doors with transom panels may be rabbeted, or installed with a metal edge and astragal, or with a transom bar between the door and transom. Rabbeted door and transom assemblies must be constructed with minimum 5 (127 mm) Firestop bottom rail of transom and top rail of door. The rabbet must be a minimum 1/2 (13 mm) deep x 7/8 (22 mm) wide. Positive pressure tested doors with transom panels must be installed in a frame with a transom bar between the door and transom. 3. If an overhead door closer is to be installed the bottom rail of the transom and the top rail of the door must be 5 (127 mm) Firestop. When transom bar is provided the rails shall be standard Firestop or Firestop II material. 4. Transom installed over a pair of fire rated doors must be separated with a frame mullion. The mullion must limit the width of each separate transom to the width of each leaf of the door pair. 5. The transom panel must be machined for spring bolts by the licensed machiner of manufacturer. The appropriate number of springbolts will be supplied by the machiner. 6. Fire rating labels will be provided on door and transom stating Door and Transom Assembly. 7. Fire rated transom panels must be installed using approved steel springbolts. The springbolts shall be placed 2 (51 mm) from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the springbolts. Panels up to 18 (458 mm) in height require 2 springbolts per side. Panels up to 36 (916 mm) in height require 3 springbolts per side. Panels up to 40 (1220 mm) in height require 4 springbolts per side. Maximum clearance between the frame and panel must be 1/8 (3.2 mm). 8. Neutral pressure tested fire doors with transoms are available in single openings up to 4 0 x Positive pressure tested fire doors with transoms are available in single openings up to 4 0 x 9 0. Neutral pressure tested fire doors with transoms are available in paired openings up to 8 0 x Positive pressure tested fire doors with transoms are available in paired openings up to 8 0 x 9 0. Maximum transom panel size in a single opening up to 4 0 wide x 3 4 high. Maximum transom panel size in a paired opening is 4 0 wide x 3 4 high. Transom panels above pairs of doors must be separated by a mullion.

22 21 Doors with Tramsoms (45/60/90 Minute Fire Rated) 45/60/90 MINUTE DOOR WITH TRANSOM Transom 5 Wide Firestop Rails Min. 1/8 Max. Gap 5 Wide Firestop Rails Min. 1/8 Max. Gap Steel Astragals 1-3/4 1-3/4 45/60/90 MINUTE DOOR WITH TRANSOM IN FRAME WITH MULLION Transom G-P Firestop Composition 1 Wide Firestop Rails Min. Mullion G-P Firestop Composition 1 Wide Firestop Rails Min. 45/60/90 Minute Doors with Transoms 1. Neutral pressure tested fire doors with transoms may be provided with: a. Straight cut meeting edges of door and transom with an over lapping astragal. b. Straight cut metting edges of door and transom with frame transom bar. c. Rabbeted meeting edges of door and transom. Rabbeted meeting edges require 5 (127 mm) bottom rail of tramson and top rail of door. Positive pressure tesed fire doors with transoms must be installed in a frame with transom bar between the door and transom. 2. A maximum 1/8 (3.2 mm) clearance between door and transom is allowed in non-rabbeted applications. Maximum clearance between the frame and transom panel must be 1/8 (3.2 mm). 3. Fire rated Transom panels must be installed using approved steel springbolts. The springbolts shall be placed 2 (51 mm) from each corner with the minimum number centered on each side. Holes must be drilled in the frame to accept the springbolts. Hole locations vary with respect to rabbeted and unrabbeted transoms. Panels up to 18 (458 mm) in height require 2 springbolts per side. Panels up to 36 (916 mm) in height require 3 springbolts per side. Panels up to 40 (1220 mm) in height require 4 springbolts per side.

23 General Notes 22 Wicket Doors (Standard) 1. Requires handing of call door and wicket door. 2. Latch/lock for call door must be suitable for rabbeted application 3. Shelf and call door are not factory installed 4. Available in GPD or GCD bonded constructions only. Call Door Hinged Side Unrabbeted Rabbeted Shelf 3/32 Reveal 1-1/8 Thick Shelf Wicket Door 1-3/4 8 13/16 Shelf 2 9/16 4 Call Door Size Opening Size 4 1-3/4 Typical Rabbet Shelf Bracket

24 23 Special Machining Standard Rabbet Transom General Notes 1. Provide non-vision joint between door and transom. 2. Non-fire rated wood core door/transom units hae solid matching hardwood top rail in door and bottom rail in transom. 3. Rabbets allow 1/8 spacing between door and transom when door is in closed position. 4. Available on 20-minute rated doors/transoms. 5. May be applied to 45, 60 and 90-minute fire doors. Mineral core fire door/transom units do not have matching rails. requires special construction. 6. Available on 1-3/4 thick doors only. 7. Available in GPD or GCD bonded constructions only. Note: GPD has matching bottom rail on top leaf and matching top rail on bottom leaf. GCD has non-matching bottom rail on top leaf and non-matching top rail on bottom leaf. Radius Edge General Notes Door 1. Used on doors when specified using pivot hinges or when double acting door is specified. 2. When specified for application to lock stile, verify lock/latch hardware compatibility. Requires full face stile. 3. When specified for application to hinge stile, verify radius of edge with hardware template requirements. 4. Available on 1-3/4 thick doors only. 5. Available in GPD or GCD bonded constructions only. 6. Not available on any fire rated door. 7. Specify radius on hinge and lock edge. Available Radii (R) Convex Concave 2-1/2 1-7/8 1-1/2 1-5/32 1-5/32

25 General Notes 24 Fire Door Plant-ons Minimum spacing to edge of door or cutout. Decorative Door Plant-ons are allowed on 20, 45, 60 and 90 minute labeled fire doors. The following conditions apply: 1. Type, size and configuration are limited by the door manufacturer s tested authorities. 2. The plant-ons must be applied under label service at factory or qulaified distributor. Plant-ons may not be field applied to fire rated doors. Minimum spacing between plant-ons. Profiles offered by Graham: 1. Graham offers the following profiles. Customers may supply assembled plant-ons in other species and profiles, provided they meet the specifications for the intended use listed below. These may also be used on non-fire rated doors. 9/16 3/4 1-1/2 P-7 1-1/2 P-8 Minimum enclosed area. Twice the profile width for width of area.. 5/8 2-3/8 P-9 Specifications 20 Minute GP 45/60 Minute GP 90 Minute Max. Profile Width: 1-3/4 2-1/2 2-1/2 Max. Profile Height 3/4 3/4 3/4 Wood Specie Douglas Fir or Denser Same Same Attachment Adhesive or Mechanical Adhesive or mechanical Adhesive Spacing: to edge of door or cutout Between Plant-ons Equal or Greater than Profile Same Same Min. Enclosed Area N/A 2 Time Profile Width & Height 2 Time Profile Width & Height Coverage Mouldings may not cover in excess of 20% of door face. Mouldings may not cover in excess of 22% of door face. Mouldings may not cover in excess of 22% of door face.

26 25 Notes February, 2014

27 8 26 Full Glass/Full Warranty Door 6 12 FULL GLASS / FULL WARRANTY DOOR Maximum Size: Thickness: Stiles: Series: Faces: Coutout Size: Mouldings: Glazing Material: Warranty: 4 0 wide x 9 0 high 1-3/4 only Laminated hardwood construction or veneer banded. Available as an option only in the GPD EC and GCD EC product lines. Two ply veneered plywood, 1/8 thick, with face veneer thickness of 1/50 minimum at 12% moisture content. Mimimum stile width is 5 from edge of door to cutout. Minimum rail width is 5 from edge of door to cutout. These dimensions actual, taken from the prefit size of the door If 20 minute fire rating is required a maximum 1296 square inches of vision area is allowed. M2G (lip), M3G (beveled lip), and M6G (flush) profiles are available. All mouldings are sized for installation with 1/4 safety tempered or wired. Moulding or lite kits are not factory attached. For non-fire rated doors, mouldings must be installed using 3/32 glazing tape on both sides of the glass and must be fastened every 8 on center using 3rd finish nails (Glazing tape and finish mails are not provided). For fire rated applications follow the installation intructions for the listed and labeled lite kit specified. With listed and labeled wood or metal kits may be specified. For non-fire rated applications 1/4 tempered safety glazing must be used. 1/4 wired glazing may be specified if desired. (Glazing is not included). For fire rated applications and listed and labeled glazing materials may be specified. When finished and installed per manufacturers specifications this product carries a full lifetime warranty against manufacturer defect on interior applications. The product is not warranted for exterior application in any event. Exterior applications are those which expose a door to extremes of temperature and/or humidity regardless of the physical placement.

28 27 ElectroLynx System April, 2011 THE GRAHAM ELECTROLYNX CABLE IS EQUIPPED WITH THE ELECTROLYNX SYSTEM OF PLUG IN CONNECTORS FOR FAST, EASY, CONNECTION TO SIMILARLY EQUIPPED ASSAABLOY HARDWARE. THE ELECTROLYNX CABLE HAS 12 CONDUCTORS OF 22 GA. WIFRE, WITH ELECTROLYNX CONNECTORS. POWER OVER ETHERNET (POE) IS AVAILABLE IF REQUIRED. AVAILABLE IN GPD & GCD DOORS ONLY SINGLE CABLE LOCK EDGE VERIFY CABLE LOCATION BEFORE MODIFYING DOOR OR SURFACE APPLICATION OF HARDWARE. 3/8 HINGE EDGE 3 HINGE DOOR SINGLE CABLE 4 HINGE DOOR MULTIPLE CABLE 5 HINGE DOOR C L ELECTRIC HINGE LOCATION HARDWARE LOCATION *ELECTRIC HINGE LOCATION ELECTRIC HINGE LOCATION ELECTRIC HINGE LOCATION MULTIPLE CABLE* LOCK EDGE HINGE EDGE ELECTRIC HINGE LOCATION ELECTRIFIED TRIM 3/8 FIRE STOP BLOCKING OR WIDER FIRE STOP STILE DEPENDING ON HARDWARE REQUIREMENTS *DOOR MUST BE PREPPED WITH A MINIMUM OF 4 HINGES *THE ELECTROLYNX HINGE WILL ALWAYS BE LOCATED IN THE SECOND HINGE FROM THE FLOOR OF TWO RACEWAYS PER DOOR ON FIRE-RATED DOORS. CAN BE USED IN BOTH NEUTRAL & POSITIVE PRESSURE DOORS CATEGORY A & B

Turning nature s beauty into works of art

Turning nature s beauty into works of art f l u s h d o o r s Eggers 5-ply flush doors are the very embodiment of form marrying function - extraordinary beauty and exceptional durability. We are able to produce a variety of custom architectural

More information

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401 BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential

More information

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries

More information

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF

More information

Core and Frame Details

Core and Frame Details and Frame Details February, 2014 Contents Architectural Flush Wood Door Codes 1-2 Performance Standards 3 GRAHAM SUPREME DOOR GSD SR 35-40 4 GSD SR 41-45 5 GSD SR 31, 33, 39, and 44 6 GSD SR 46-47 7 GRAHAM

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

Wood Sound Retardant Door Hardware Information Bulletin

Wood Sound Retardant Door Hardware Information Bulletin overly overly 574 West Otterman Street Greensburg, PA 15601 Toll Free: (800) 979-7300 Local: (724) 834-7300 Fax: (724) 830-2871 Email: overly@overly.com DOOR COMPANY Wood Sound Retardant Door Hardware

More information

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA 810-09 METAL DOORS & FRAMES METAL. A Division of

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA 810-09 METAL DOORS & FRAMES METAL. A Division of HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-09 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES HOLLOW METAL DOORS 8d NAAMM HMMA 810-09 METAL DOORS & FRAMES A Division of HOLLOW METAL MANUFACTURERS A S S O C

More information

Basic Fire Door Requirements

Basic Fire Door Requirements TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door

More information

Technical Data Honeycomb Door Leaf 8-1-99

Technical Data Honeycomb Door Leaf 8-1-99 8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix

More information

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY Architectural Testing PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Mahogany Entry Door PRODUCT TYPE: 6' x 8' Double Outswing Hardwood TDL Door with Half Circle TDL Transom

More information

DE Frame with C Series Sidelight

DE Frame with C Series Sidelight TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder

More information

SECTION 6. Glass Storefront Doors:

SECTION 6. Glass Storefront Doors: SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail

More information

Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection.

Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection. DKS Customers Interested Parties State and Local Authorities Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection. All DKS products

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair 49 Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair In this chapter: The Over-the-Post Balustrade System Determining the Rail Centerline Using Rail Bolts Making a Pitch Block Laying Out

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11 K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins

More information

FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1

FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1 FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1 Issue Date: 3/3/2009 Each furniture item scheduled in this specification manual is assigned a "key" code; each key code is crossreferenced

More information

Architectural Casework 06400-01. 1.01 Description of Work

Architectural Casework 06400-01. 1.01 Description of Work 06400-01 1.01 Description of Work A. Extent of each type of architectural millwork and casework as indicated on drawings. Types of architectural casework shall include both stained and plastic laminated

More information

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1

More information

SECTION 062043 FIRE-RATED WOOD JAMBS

SECTION 062043 FIRE-RATED WOOD JAMBS SECTION 062043 FIRE-RATED WOOD JAMBS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. [Solid wood] [Particle board] fire-rated interior door[ and sidelight] frames. 2. Intumescent/wood fire-rated interior

More information

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED CERTIFICATE OF APPROVAL No CF 291 This is to certify that, in accordance with TS General Requirements for Certification of Fire Protection Products The undermentioned products of Drummond Road, Stafford.

More information

AZEK Rail Install Guide

AZEK Rail Install Guide TRIM MOULDING DECK PORCH RAIL PAVERS AZEK Rail Install Guide Installing AZEK Rail with Glass Infill... 2 Installing AZEk Rail Stairs with Glass Infill... 9 Notes...14 Please read all instructions completely

More information

Ladder Shelf Plans Final dimensions: 25 L x 21 W x 72 H

Ladder Shelf Plans Final dimensions: 25 L x 21 W x 72 H Ladder Shelf Plans Final dimensions: 25 L x 21 W x 72 H Copyright 2011. MLCS Woodworking. Page 1 Router bits and supplies needed: 3/8 Rabbeting bit (#10691) 1 Bottom Cleaning bit (#7941) Top and Bottom

More information

Garden Windows Builders Vinyl

Garden Windows Builders Vinyl TABLE OF CONTENTS Specifications... 8-2 QuickSpecGuide... 8-3 Elevations/Sizes: 1/4 Scale GardenUnits... 8-4 Grille Patterns... 8-5 SectionDetails: 6 Scale... 8-6 December 2008 JELD-WEN reserves the right

More information

Premier & Deluxe 3-Season Room Sliding Glass Door

Premier & Deluxe 3-Season Room Sliding Glass Door DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen

More information

AMERICAN GOTHIC PLAYHOUSE

AMERICAN GOTHIC PLAYHOUSE AMERICAN GOTHIC PLAYHOUSE Project Plan #856 Sheet 1 of 5 Pick a spot and get started with the beautiful that your kids will love. The design of the playhouse includes 35 square feet of interior space plus

More information

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS International Code Council National Fire Protection Association Underwriters Laboratories Inc. 5203 Leesburg Pike, Suite 600 1 Batterymarch

More information

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing) Custom Blank Entrances - Applied Hardware & Preps - Tubelite Standard Hardware Butt Hinges Pivots C2 Page 1 P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing) P795S

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

Ceiling Mounted Folding Attic Ladders Installation Instructions

Ceiling Mounted Folding Attic Ladders Installation Instructions Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

Residential Garage Door Terminology

Residential Garage Door Terminology A Air Infiltration: The leakage or passage of air through a door system Anodize: A hard non-corrosive oxide film on the surface of aluminum Astragal: A compressible or deformable seal provided on the bottom

More information

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit. Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden

More information

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE FITTING YOUR KITCHEN GUIDE How to mark out a kitchen PAGE 1 Before starting on the installation, measure 870mm from the lowest point of the floor and mark a datum line around the room to indicate where

More information

Important Information for Installer & Homeowner

Important Information for Installer & Homeowner Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side

More information

Gate Leg Drop Leaf Table Plans

Gate Leg Drop Leaf Table Plans Preparing the table top blanks: Cut and glue enough 3/4 stock to make three panels 40 long by 24 wide (they will be cut to final size at a later time). While the glue dries we will work on the legs. Preparing

More information

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22

More information

glass & Glazing Products

glass & Glazing Products glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

A Complete Solution CREATING WALLS THAT DEFINE SPACE

A Complete Solution CREATING WALLS THAT DEFINE SPACE A Complete Solution CREATING WALLS THAT DEFINE SPACE COMPANY HISTORY CLIPPER WALL Clipper partitions are part of the Saint- Gobain Group, one of the worldwide leaders in the construction products industry.

More information

AZEK Rail Install Guide

AZEK Rail Install Guide TRIM MOULDING DECK PORCH RAIL PAVERS AZEK Rail Install Guide Installing AZEK Rail with CableRail by Feeney... 1 Installing CableRail by Feeney for AZEK Rail... 7 Installing AZEK Rail Stairs with CableRail

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

All-Season Sunroom Sliding Glass Door Installation Instructions

All-Season Sunroom Sliding Glass Door Installation Instructions ASRESGD-08 All-Season Sunroom Sliding Glass Door Installation Instructions Panel Frame Door Frame Left Side Foam Insulator IE241 H Bar Assembly Door Frame Top Track Panel Frame Door Frame Right Side Stationary

More information

DIY CABINET REFACING INSTALLATION GUIDE

DIY CABINET REFACING INSTALLATION GUIDE DIY CABINET REFACING INSTALLATION GUIDE CABINET REFACING INSTALLATION Are you ready to reface your outdated cabinets? This guide will show you how to install your new Facelifters Cabinet Refacing Products

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

Installation Instructions and Ordering Information

Installation Instructions and Ordering Information The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

DOOR COMPONENTS, INC Technical Data

DOOR COMPONENTS, INC Technical Data DOOR COMPONENTS, INC Technical Data DOOR COMPONENTS, INC 7980 Redwood Ave Fontana, CA 92336 Phone (909) 770 5700 Toll Free (866) 989 3667 Fax (909) 770 5722 www.doorcomponents.com INDEX FRAMES: PAGE #

More information

Installing Window and Door Mouldings

Installing Window and Door Mouldings Installing Window and Door Mouldings About Window and Door Mouldings The trim around windows and doors greatly influences the look and style of your interior. They also bridge the gaps and cover spaces

More information

RadianceRail Installation Guide

RadianceRail Installation Guide RadianceRail Installation Guide Installing RadianceRail with CableRail by Feeney... 2 Installing CableRail by Feeney for RadianceRail... 7 Installing RadianceRail Stairs with CableRail by Feeney... 10

More information

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows Series 2050 Garden Window The Series 2050 standard garden window has an outstanding reputation for its distinctive design and excellent

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

Brick Veneer Construction

Brick Veneer Construction Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power

More information

Stair Parts Installation. Tricks

Stair Parts Installation. Tricks Stair Parts Installation Tips & Tricks Introduction Your DIY staircase guide Welcome to the Stairpart home installation guide. Your stairway is both a functional and focal point in your home, so keeping

More information

Andersen Clad Inswing Entry Doors (2001 to Present)

Andersen Clad Inswing Entry Doors (2001 to Present) Andersen Clad Inswing Entry Doors (2001 to Present) What s in This Section Clad Inswing Entry Doors Page 3 Part Illustrations 3 Parts Illustration - Single Door 3 Parts Illustration - Double Door 4 Parts

More information

Combination & Screen Doors

Combination & Screen Doors Combination & Screen Doors www.bbwood.com WOOD SCREEN DOORS Removable Screens (RS) SPECIFICATIONS: Stiles and Top Rail 2-9/16 Cross Rails Bottom Rail Vertical Mull 7/8 #206 #201 58-RS 764-RS V52-RS 2 2

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg Thank you for selecting JeLd-weN products. Attached are JeLd-weN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to

More information

Installation Instructions

Installation Instructions Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step

More information

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: MEANS OF EXIT / ESCAPE / EGRESS Guidelines: This checklist covers some of the regulations

More information

These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts.

These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts. No 8 in the series of 'How to' brochures produced by PlaceMakers, New Zealand How to Frame and Hang a Door These instructions will show you how to install an internal door into a non-loadbearing partition

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

Clad Direct Glaze Window Installation Instructions

Clad Direct Glaze Window Installation Instructions Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully

More information

REPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

REPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012 TEST REPORT REPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012 EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Fire Door Caulk LLC.

More information

Delivery Split delivery Off Hr delivery Store off site To tailgate To floor Accepted by

Delivery Split delivery Off Hr delivery Store off site To tailgate To floor Accepted by ARCHITECTURAL WOODWORK QUALITY STANDARDS SPECCHEK INSERT MODULAR CABINETS AWI Grades Transparent Fin. Opaque Fin. Laminate clad By room By floor By item Size Width Height Thickness Construction Flush overlay

More information

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit. Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden

More information

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions For Slider Casement Air Conditioners Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT

More information

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast

More information

TopSky DLG Installation Manual

TopSky DLG Installation Manual TopSky DLG Installation Manual Attention: Because after the compound materials solidify, there will be ammonia iris on the surface, which affect the bonding strength afterwards. Please polish with sandpaper

More information

Tundra Series Windows January 2016

Tundra Series Windows January 2016 Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing

More information

CONTEMPORARY - TRANSITIONAL RECEPTION STATIONS

CONTEMPORARY - TRANSITIONAL RECEPTION STATIONS Reception stations, the first impression expressed to visitors in your office. Transitional styling to coordinate with your other office settings, available in a selection of 16 walnut, cherry, oak, maple

More information

Casement/Awning Window Parts Reference Catalog

Casement/Awning Window Parts Reference Catalog Casement/Awning Window Parts Reference Catalog (Includes Miscellaneous Parts for Eyebrow Casement and Garden Bay Windows) #1028654 (Revised 03/02) Weather Shield Mfg., Inc. Medford, WI 54451 715/748-2100

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

How to secure your property after a disaster

How to secure your property after a disaster How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,

More information

Stainless Steel Continuous Hinges

Stainless Steel Continuous Hinges Stainless Steel Continuous Hinges Hager heavy duty continuous hinges offer proven reliability that can stand up to the daily rigors of high-traffic, high-impact areas. They re designed and engineered to

More information

FIRE GLASS TO GO! Fire Glass Solutions from

FIRE GLASS TO GO! Fire Glass Solutions from Fire Glass Solutions from FIRE GLASS TO GO! INTRODUCING For almost 20 years, the company now trading as CGI International has been involved in the manufacture and distribution of specialist fireresisting

More information

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows Viewed from the exterior. IMPORTANT: Please read before you begin installation. TABLE OF CONTENTS AND TOOL / MATERIAL

More information

Wine Rack & Glass Storage Bench Chris Gardner

Wine Rack & Glass Storage Bench Chris Gardner Wine Rack & Glass Storage Bench Chris Gardner Quantity Length Width Material Part 2 48 16 3/4 birch plywood top, bottom 2 14 16 3/4 birch plywood sides 2 14 13 3/4 birch plywood support dividers 2 3 15

More information

Pre-Cut Sauna Specifications

Pre-Cut Sauna Specifications Pre-Cut Sauna Specifications When to specify a Pre-Cut Liner Sauna: Please review diagrams at the beginning of these specs. Pre-Cut saunas are best suited for projects that require the four walls and ceiling

More information

Best Barns USA Assembly Book

Best Barns USA Assembly Book Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.

More information

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Introduction...COMB-2 Design Considerations and Examples...COMB-3 SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant

More information

Pyroguard Wired Glass

Pyroguard Wired Glass Fire-rated Glass Pyroguard Wired Glass Where glass becomes architecture Section 15 03 Introduction Oldcastle Glass stocks nonwired Pyroguard laminated safety glass and polished wired glass for commercial,

More information

Wren Kitchens Installation Tips... 3. Carefully check your kitchen delivery... 4. Measuring out and marking up... 5. Fitting the base cabinets...

Wren Kitchens Installation Tips... 3. Carefully check your kitchen delivery... 4. Measuring out and marking up... 5. Fitting the base cabinets... tra 1 Index Wren Kitchens Installation Tips... 3 Carefully check your kitchen delivery... 4 Measuring out and marking up... 5 Fitting the base cabinets... 6 Fitting the corner cabinets... 7 The 972mm or

More information

CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE

CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE CONCEALED BEARING HINGES StANLEy ARCHItECtuRAL HARDwARE STANLEY ARCHITECTURAL HARDWARE TABLE OF CONTENTS Page Table of contents...2 Company history...2 5 knuckle concealed bearing design...3 Full mortise

More information

Doors and frames. Technical data manual 2015 rev. 8/17/15

Doors and frames. Technical data manual 2015 rev. 8/17/15 Doors and frames Technical data manual 2015 rev. 8/17/15 Technical data manual Main table of contents NAVIGATE VIA: A) Rollover links in each TOC (each item below is a link), B) Bookmarks on the left,

More information

Basic Technical Fundamentals of Builders Hardware

Basic Technical Fundamentals of Builders Hardware Basic Technical Fundamentals of Builders Hardware Mortise Locks Bored Locks Auxiliary Locks Inside Cover (blank) Table of Contents SARGENT History...4 Basic Name of Products...5, 6 Doors (A Brief Review)...7

More information

security solutions for your home

security solutions for your home security solutions for your home www.prowlerproof.com.au Copyright 2004 Gershwin Pty Ltd ABN 220 641 02816 PRODUCT APPLICATIONS PRODUCT RANGE Prowler Proof manufactures a full range of products to suit

More information

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01 HOLLOW METAL MANUAL NAAMM STANDARD HMMA 830-02 METAL S & FRAMES 8d NAAMM 01 02 HARDWARE SELECTION FOR HOLLOW METAL S AND FRAMES NAAMM 01 02 8d METAL S & FRAMES A Division of HOLLOW METAL MANUFACTURERS

More information

Fire-Rated Doors and Hardware. A Guide to Field Inspection

Fire-Rated Doors and Hardware. A Guide to Field Inspection Fire-Rated Doors and Hardware A Guide to Field Inspection Foundation s Mission To promote secure and safe openings that enhance life safety Awareness To be a source of information through awareness campaign

More information

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN HOW TO INSTALL A BEAUTIFUL NEW KITCHEN Easy to follow step-by-step kitchen cabinet installation TOOL AND MATERIAL LIST Hammer Pry bar Screwdriver Phillips Flathead Level Tape measure Pencil Straight edge

More information

STANDARD OPEN PATIO COVER

STANDARD OPEN PATIO COVER STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs. FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds

More information

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction. SECTION 081216 - INTERIOR ALUMINUM DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B8049.01-401-18. Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B8049.01-401-18. Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida Architectural Testing MIAMI-DADE COUNTY PERFORMANCE TEST REPORT Report No.: B8049.01-401-18 Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida PRODUCT TYPE: Aluminum Storefront with Double Doors SERIES/MODEL:

More information

2.9 WINDOW & DOOR BUCKS

2.9 WINDOW & DOOR BUCKS 2.9 WINDOW & DOOR BUCKS Bucks provide attachment surfaces for windows and doors while holding back concrete from these openings during concrete placement. Mark the center and edges of openings as you place

More information

How to Build a Poker Table

How to Build a Poker Table How to Build a Poker Table www.pokertablematerials.com 10-Person Poker Table- 96 x 48 These are step by step instructions for building a poker table. The table will measure 48" x 96" and have a 4" wide

More information

New Product Announcement

New Product Announcement New Product Announcement Tristar Glass is now the exclusive provider of Schott PYRAN Platinum Fire- and Safety-Rated Glass-Ceramics for Arkansas, Oklahoma, and Texas. Tristar is giving our select network

More information