2 Page : 1 of 39 EMC TEST REPORT Test report No: Type of Equipment : Model Name: Variant Model Name: Applicant: Manufacturer #1: Manufacturer #2: EMC-CE-1338 CCTV CAMERA HD61X HD73X, CNB-D2750PVR, CNB-V1760PVR CNB Technology Inc. CNB Technology Inc. CNB Electronic (shenzhen) Co., Ltd Test standards : EN 55022:2006, Class A EN :1995+A1:1998+A2:2003 Testing Laboratory : Test result : Complied This product complies with the requirements of the EMC Directive 2004/108/EC. The results in this report apply only to the sample tested. This test report shall not be reproduced except in full, without the written approval of EMC compliance Laboratory. Receipt date: Date of testing: ~ Issued date: Tested by: Approved by: PARK, YONG-JIN CHUNG, MIN-SEOK

3 Page : 2 of 39 Contents 1. Applicant information Laboratory information Test system configuration Operation environment 3.2 Measurement Uncertainty 4. Description of E.U.T General information 4.2 Product description 4.3 Auxiliary equipments 4.4 Test configuration 4.5 Operating conditions 5. Summary of test results Modification to the E.U.T. 5.2 Summary of EMI emission test results 5.3 Summary of immunity test results 5.4 Performance criteria 6. Test results Radiated Emission 6.2 Electrostatic Discharge test result 6.3 Radio Frequency Electromagnetic Fields 6.4 Electric Fast Transient/BURST 6.5 Surge 6.6 Conducted Immunity 7. E.U.T. photographs

4 Page : 3 of Applicant information Applicant : CNB Technology Inc. Address : #701,star valley,60-11 Gasan-Dong, Geumcheon-Gu, Seoul, , Korea Telephone : Fax. : kira1227@cnbtec.com Contact name : LEE KI SUNG Manufacturer#1 : CNB Technology Inc. Address : #701,star valley,60-11 Gasan-Dong, Geumcheon-Gu, Seoul, , Korea Telephone : Fax. : kira1227@cnbtec.com Contact name : LEE KI SUNG Manufacturer#2 : CNB Electronic (Shenzhen) co., Ltd Address : 4~5/F.,4 Bldg kingwingtat technology industry Park gangtou village, buji town, long gang district Shenzhen,p.r.china Telephone : Fax. :

5 2. Laboratory information Page : 4 of 39 Address EMC compliance Ltd. Telephone Number : Facsimile Number : CBTL Testing Laboratory FCC Filing No.: FCC CAB.: KR0040 VCCI Registration No. : C-1713, R-2710, T-258 KOLAS NO.: 231 SITE MAP Yongin city EMC compliance

6 3. Test system configuration Page : 5 of Operation environment Temperature Humidity Pressure OATS : 19 C 40 % - Immunity area : 20 C 41 % 1000 hpa Test site These testing items were performed following locations; Semi-anechoic chamber: Radiated Emission #4(3m) OATS : Radiated Emission (10m) Anechoic chamber (3m) : RS Immunity area :, ESD, EFT/Burst, Surge, CS

7 3.2 Measurement Uncertainty Page : 6 of 39 All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are test receiver, cable loss, antenna factor calibration, Antenna directivity, antenna factor variation with height, antenna phase center variation, antenna frequency interpolation, measurement distance variation, site imperfection, mismatch, and system repeatability. Based on NIS 80, 81, the measurement uncertainty level with a 95% confidence level was applied. Radiated Emission measurement :(k=2, 95%) MHz ; 3 m: ±3.73 [db], 10 m: ±3.71 [db] MHz ; 3 m: ±3.81 [db], 10 m: ±3.80 [db] Radio Frequency Electromagnetic Fields :(k=2, 95%) ± [db]

8 Page : 7 of Description of E.U.T. 4.1 General information - HD61X is a CCTV camera. 4.2 Product description Type of product: Model name (Basic): CCTV CAMERA HD61X Model name (Variant): HD73X, CNB-D2750PVR, CNB-V1760PVR HD73X: High Resolution Difference: CNB-D2750PVR: CNB BRAND of HD61X CNB-V1760PVR: CNB BRAND of HD73X Serial no: - Trade name : - Testing Voltage: Product rating: Note : DC 12V DC 12V This test was done with HD61X.

9 4.3 Auxiliary equipments Page : 8 of 39 Type Model / Part # Serial number Manufacturer Monitor CX911MW N732H1IL900530W SAMSUNG DC power supply 6032A US HP 4.4 Test configuration

10 Page : 9 of 39 Type Description Connection (To) Spec. Length(m) Note * Signal Power Power supply (DC 12V) Non-Shield BNC cable Monitor Shield Operating conditions The EUT was configured as normal intended use. Test mode 1 Display mode. Normal operating

11 5. Summary of test results Page : 10 of Modification to the E.U.T. None 5.2 Summary of EMI emission test results Application Test method Test result Conducted emission EN Class A N/A Radiated emission EN Class A Complied Harmonics current EN :2006 N/A Voltage fluctuations and flickers EN :2005 N/A 5.3 Summary of immunity test results Items Application Test method Test result Electrostatic discharge Enclosure EN :1995+A1+A2:2001 Complied Radiated RF immunity Enclosure EN :1995+A1:2002 Complied Fast transient Surge Conducted RF immunity Magnetic field immunity Voltage dip/interruption DC 12V Signal DC 12V Signal DC 12V Signal EN :1995+A1+A2:2004 EN :1995+A1:2001 EN :1996+A1:2001 Complied Complied Complied Enclosure EN :1994+A1:2001 N/A DC 12V EN :2004 N/A Voltage variation DC 12V EN :2003 N/A

12 5.4 Performance criteria Page : 11 of 39 The variety and the diversity of the apparatus within the scope of this document makes it difficult to define precise criteria for the evaluation of the immunity test results. If as a result of the application of the tests defined in this standard, the apparatus becomes dangerous or unsafe then the apparatus shall be deemed to have failed the test. A functional description and a definition of performance by the manufacture and noted in the test report, based on the following criteria: Electrostatic discharge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, Radiated electromagnetic fields There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing which could be interpreted by associated equipment as a change, and no such Flickering of indicators occurs at a field strength of 3V/m. For components of CCTV systems, where the picture is allowed at 10V/m, providing. (a) there is no permanent damage or change to EUT (e.g. no corruption of memory or changes to programmable setting etc.) (b) at 3V/m, any deterioration of the picture is so minor that the system could still be used; and (c) there is no observable deterioration of the picture at 1V/m. Fast transient burst / slow high energy voltage surge There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U=130dBuV. For components of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U=140dBuV, providing: (a) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.):

13 Page : 12 of 39 (b) at U =130dBuV, any deterioration of the picture is so minor that the system could still be used; and (c) there in no observable deterioration of the picture at U +120dBuV. Conducted RF immunity There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of discharge is permissible, providing That there is no residual is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators oeuvres at U=130DBuv. For component of CCTV systems, where the status is monitored by observing the TV picture, then deterioration of the picture is allowed at U=140dBuV, providing: (d) there is no permanent damage or change to the EUT (e.g. no corruption of memory or changes to programmable settings etc.): (e) at U =130dBuV, any deterioration of the picture is so minor that the system could still be used; and (f) there in no observable deterioration of the picture at U +120dBuV. Voltage dip/interruption There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. The EUT shall meet the acceptance criteria for the functional test, after the conditioning.

14 Page : 13 of Test results 6.1 Radiated Emission Test specification Test mode EN Sections 6, Class A Display mode. Date Power supply DC 12V Semi-anechoic chamber #4, Test facility 10m OATS Temperature ( C) 18 C Humidity (%) 39 % Remarks Complied Minimum limit margin is 1.00 db at MHz Limits of radiated emission measurement Frequency [MHz] Class A(dBuV/m)@10m Class B(dBuV/m)@10m Above 1000MHz Measurement procedure A pretest was performed at 3m distance in a semi-anechoic chamber for searching correct frequency. The final test was done at a 10m open area test site with a quasi-peak detector. EUT was placed on a non-metallic table height of 0.8m above the reference ground plane. Cables were folded back and forth forming a bundle 0.3m to 0.4m long and were hanged at a 0.4m height to the ground plane. Cables connected to EUT were fixed to cause maximum emission. Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.

15 Page : 14 of Used equipments Equipment Model no. Serial no. Makers Next cal. date Test Receiver ESCI R&S TRILOG SUPER BROADBAND ANT VULB Schwarz beck Antenna Mast A109 N/A DAEIL - Used Turn Table TS25 N/A DAEIL - 10m OATS - - EMC Compliance Sample calculation The field strength is calculated adding the antenna Factor, cable loss and, Antenna pad adding, subtracting the amplifier gain from the measured reading. The sample calculation is as follow: FS = MR + AF + CL + AT -AG MR = Meter Reading AF = Antenna Factor CL = Cable Loss AP = Antenna Pad AG=Amplifier Gain If MR is 30dB, AF 12dB, CL 5dB, AP 10dB, AG 35dB The result (MR) is = 22dBuV/m

16 6.1.5 Photographs of test setup Page : 15 of 39

17 6.1.6 Radiated emission measurement result *3m Semi-anechoic chamber Pre-scan Data ( #4) -Horizontal Page : 16 of 39 -Vertical

18 *10m OATS measurement data Page : 17 of 39 Frequency Reading Pol. Correction Height angle Factor Limits Result Margin [MHz] [dbuv/m] [m] Antenna Cable [dbuv/m] [dbuv/m] [db] V V H V H V H H * Note : Reading = Test Receiver value,

19 6.2 Electrostatic Discharge test result Test specification Test level Discharge impedance Power supply EN :2001 Contact: ± 2, 4, 6 kv Air: ± 2, 4, 8 kv HCP / VCP : ± 2, 4, 6 kv 330 Ω/150 DC 12V Page : 18 of 39 Date Number of discharge 10 Interval between discharges : 1s Temperature( C) 20 C Humidity (%) 41% Pressure (mb) 1000 mb Remarks Complied - There was no change of operation status during above testing.(a1) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(c1, A2) Measurement procedure A ground reference plane was located on the floor, and connected to earth via a low Impedance connection. The return cable of the ESD generator was connected to the reference plane. In case of floor standing equipment, EUT was placed on the reference plane on 0.1 m of insulating Support. In case of table top equipment, EUT was placed on a wooden table 0.8m above the reference grounded floor. A horizontal coupling plane(hcp) was placed on the table, and Connected to the reference plane via a 470 resistor located in each end (0.5mm insulating support between EUT and HCP). In both cases a vertical coupling plane(vcp) OF 0.5 X 0.5m was located 10cm from the EUT s sides. The VCP was connected to the reference plane in the same matter as the HCP.

20 6.2.2 Used equipments Page : 19 of 39 Equipment Model No. Serial No. Makers Next Cal. Date ESD Tester PESD 1600 H HAEFELY HCP VCP Used Photographs of test setup

21 6.2.4 Measurement result Electrostatic Discharge (Test Point) Page : 20 of 39 Air discharge Contact discharge

22 Page : 21 of 39 Contact discharge Location(EUT) Applied level (±) Result C1 Screw ±2,4,6KV Complied HCP (All 4 sides) ±2,4,6KV Complied VCP (All 4 sides) ±2,4,6KV Complied Air discharge Location(EUT) Applied level(±) Result A1 EUT case ±2,4,8KV Complied A2 Power port ±2,4,8KV Complied

23 6.3 Radio Frequency Electromagnetic Fields Test specification EN :2002 Page : 22 of 39 Tested frequency Test level & Modulation Distance Dwell time Step size Power supply 80MHz 2000MHz log 1% step 1,3,10 Vrms, 80% Amplitude Modulation(1kHz) 1,3,10 Vrms, Pulse Modulation (1Hz (0.5s ON: 0.5 s OFF)) 3m from EUT to tip of antenna 3S 1% step DC 12V Date Temperature( C) 19 C Humidity (%) 40% Pressure (mb) 1002 mb Remarks Complied - There was no change of operation status during above testing.(1v) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(3v,10v) Measurement procedure The test was performed at 3m full anechoic chamber. For floor standing equipment, the EUT was standing on the floor. For tabletop equipment, the EUT was located on a wooden table 0.8m above the floor. The EUT was tested all sides, horizontal and vertical polarization. The field uniformity was calibrated for 1V/m, 3V/m, 10V/m Used equipments Equipment Model no. Serial no. Makers Next Cal. date Power meter PM AR Power sensor (with adapter) Power sensor (with adapter) PH AR PH AR Directional coupler DC AR Signal generator E4421B GB AGILENT Used

24 Page : 23 of 39 Amplifier 150W1000M AR Directional Coupler DC7144M AR Amplifier 60S1G3M AR BiconiLog Ant. LPDA ETS - BiconiLog Antenna 3142B 1786 EMCO - Field monitor SI TDK - Controller HD Deisel - Turn table DS 412S - Deisel - Antenna mast MA Deisel Photographs of test setup Measurement result Location(EUT) Antenna polarization Result Front side Horizontal Complied Vertical Complied Rear side Horizontal Complied Vertical Complied Left side Horizontal Complied Vertical Complied Right side Horizontal Complied Vertical Complied

25 6.4 Electric Fast Transient/BURST Page : 24 of 39 Test specification EN : 2004 Coupling Test level Repetition frequency Coupling time Power supply DC 12V,Signal: Clamp DC 12V : ± 1 kv Peak Signal : ± 1 kv Peak 5 khz, Tr/Th = 5/50nS 60s DC 12V Date Temperature( C) 20 C Humidity (%) 41% Pressure (mb) 1002 mb Remarks Complied - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally Measurement procedure A ground reference plane was located on the floor. EFT generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.1 m wooden table. For tabletop equipment, EUT was placed on a 0.8m above the ground reference plane. Test generator and coupling/decoupling network was placed on, and bounded to, the ground reference plane. When using the coupling clamp, the minimum distance between the coupling plates and all other conductive surfaces, except the ground reference plane beneath the coupling clamp, Shall be 0.5m Used equipments Equipment Model No. Serial No. Makers Next Cal. date Generator UCS 500 M6 V EM TEST Capacitive Coupling Clamp - - EM TEST - Used

26 6.4.3 Photographs of test setup Page : 25 of 39

27 6.4.4 Measurement result DC 12V Page : 26 of 39 EFT coupling point (+) (-) Result L(+) +1KV -1KV Complied N(-) +1KV -1KV Complied L-N +1KV -1KV Complied Signal EFT coupling point (+) (-) Result BNC cable +1KV -1KV Complied

28 6.5 Surge Page : 27 of 39 Test specification EN :2001 Coupling DC 12V Test level Surge pulse shape Coupling Impedance DC 12V: 0.5,1 KV Signal: 0.5,1 KV Tr/Th =1.2/50uS DC12V: 40Ω+0.5 Signal (BNC): Direct Angles 0,90,180,270 Number of surge & Coupling time Power supply 5T/1min DC 12V Date Temperature( C) 20 C Humidity (%) 41% Pressure (mb) 1001 mb Remarks Complied - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally Measurement procedure A ground reference plane was located on the floor. SURGE generator was connected to reference ground plane via low impedance connection. For floor standing equipment, EUT was placed on a 0.8 m wooden table. For tabletop equipment, EUT was placed on a wooden table (0.8m) above the reference plane Used equipments Equipment Model No. Serial No. Makers Next Cal. date Generator UCS 500 M6 V EM TEST CDN CNV EM TEST - Used

29 6.5.3 Photographs of test setup Page : 28 of 39

30 6.5.4 Measurement result Page : 29 of 39 DC 12V Coupling point (+) (-) Result L-N +0.5,1KV -0.5,1KV Complied Signal Coupling point (+) (-) Result BNC cable +0.5,1KV -0.5,1KV Complied

31 6.6 Conducted Immunity Page : 30 of 39 Test specification EN :2001 Tested frequency Test level & Modulation Coupling method Step size Power supply 150 KHz 100 MHz 1% step 1,3,10 Vrms, 80% Amplitude Modulation(1kHz) 1,3,10 Vrms, Pulse Modulation (1Hz (0.5s ON: 0.5 s OFF)) DC 12V : M2 Signal : clamp 1% step DC 12V Date Temperature( C) 19 C Humidity (%) 40% Pressure (mb) 1002 mb Remarks Complied - There was no change of operation status during above testing.(1v) - During the test, some of flickering phenomenon happened. After this test, EUT was operated normally.(3v,10v) Measurement procedure A ground reference plane was located on the floor. The test was performed on a ground reference plane on a 0.1m wooden table. This test were performed using CDN for mains, clamp for signal and injection probe. The frequency range was swept from 150 khz to 100MHz.This frequency range was Modulated with 1 khz sine wave at 80%. The signal generators provided the modulated frequency at a 1% step size. The power and all network cable, I/O cables longer than 3m in length were tested.

32 6.6.2 Used equipments Page : 31 of 39 Equipment Model no. Serial no. Makers Next Cal. date CS generator CWS 500 C S1 V EM TEST Used CDN CDN M2/M EM TEST Attenuator MU918 MCE/WEINSCHEL EM Clamp KEMZ Schaffner EM Clamp KEMA Scahffner - Current probe MD720 W /M6/ 0068 Schaffner Photographs of test setup

33 Page : 32 of Measurement result Coupling point Coupling method Result Power CDN (M2) Complied BNC cable Clamp Complied

34 7. E.U.T. photographs Page : 33 of 39 Front View Rear View

35 Inside Page : 34 of 39

36 Main Board Page : 35 of 39

37 Power Board Page : 36 of 39

38 LED Board Page : 37 of 39

39 Lens Page : 38 of 39

40 SUB Board Page : 39 of 39

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNO-6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNP-6200RHP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment Brand Name /Trade Mark Type designation /model Applicant Network Camera SAMSUNG SND-5083P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SNP-5300P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd. www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman

More information

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20 EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan

More information

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),

More information

EMC TEST REPORT For. Webcam. Model Number: CAM67U

EMC TEST REPORT For. Webcam. Model Number: CAM67U EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology

More information

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electromagnetic Compatibility Test Report Test results of Floww equipment Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original

More information

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail. EMC TEST REPORT Project No. LBE091881 Revision No. NONE Name of organization Samsung Electronics Co., Ltd. Applicant Address 416 Maetan 3-Dong,Yeongtong-Gu,Suwon-Si, Gyeonggi-Do, 443-742 Korea Date of

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E Page: 1 of 38 EMC TEST REPORT Reference No. Applicant Address : WT08010091-S-E : Gembird Electronics Ltd. : Room 1709 A, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) :

More information

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z) CERTIFICATE Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03 This is to certify that the following designated product Product Trade name Model Number : 1 Port Device Server : Moxa : NPort 5150(-T),

More information

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 Phone: +86-755-83585700 3A, F1.6, Tianfa Building, Tian an Cyber Park, Fax: +86-755-83585701 Futian

More information

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. 588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 23 1 Cover Page Application No.: Applicant: Manufacturer:

More information

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical. 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological Development District, Guangzhou, China 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: sgs_internet_operations@sgs.com

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. 음 Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Digital Video Recorder SAMSUNG SRD-1656DP SAMSUNG TECHWIN CO., LTD. In accordance with the following

More information

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010 ELECTROMAGNETIC COMPATIBILITY TEST Report reference N R-255 EMC 2010 Constructor. Address Reference person. C LUCE S.r.l. Via Marmolada 5/11 20060 Truccazzano (MI) Italy ---- Product....... Model......

More information

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613 Report No.: 0000091428 31160742.001 Page 1 of 36 Electromagnetic Compatibility Test Report Prepared in accordance with EN 55022: 2006, +A1: 2007 On DC DC umodule Regulator LTM4613 For Linear Technology

More information

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT

More information

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement TEST REPORT Applicant Address Shenzhen Gembird Electronics Ltd. 5F, Building B, Shi-Feng Industrial Zone, Hua-Ning Rd., Xin-Wei Village, Da-Lang Street, Long-Hua, Bao-An Area, Shenzhen 518109, Guangdong

More information

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology Antennas for EMC Testing Zhong Chen ETS-Lindgren 1301 Arrow Point Drive Cedar Park, TX 78613 Zhong.Chen@ets-lindgren.com Outline EMC Terms and Definitions Typical EMC Antennas Calibration of EMC Antennas

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations.

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J113-41 test set up, using measured current in NEC and simple TX equations. D. A. Weston RE02Tx.rep 14-6-2004 NARTE Certified EMC

More information

Cond-IS RF Conducted Immunity System

Cond-IS RF Conducted Immunity System Cond-IS RF Conducted Immunity System About RF Conducted Immunity In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) RF Conducted Immunity compliance verification

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND-5084RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015 Report Of Shielding Effectiveness Test For SafeSleeve Radiation Shielding Technology Test Date(s): June 07 June 09, 2015 Issue Date: June 10, 2015 UST Project No: 15-0137 Total Number of Pages Contained

More information

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output Evaluation of Anechoic Chambers For EMC Measurements Using A CNE Overview Anechoic chambers are used for EMC testing primarily for radiated emissions (RE) and radiated immunity (RI) in the frequency range

More information

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps

More information

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT For AeroComm, Inc. 10981 Eicher Drive Lenexa, KS 66219 2003-05-22 This Report Concerns: Original Report Equipment Type: 900MHz Transceiver Test Engineer:

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Radiated Emission and Susceptibility

Radiated Emission and Susceptibility Radiated Emission and Susceptibility Tzong-Lin Wu, Ph.D. EMC Lab Department of Electrical Engineering National Taiwan University Differential-Mode v.s. Common-mode Currents 1 Differential-Mode v.s. Common-mode

More information

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK EMC Technology Product Section Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK Shonai Corporation Satoru Saito Reduce Emission Noise from Cables Even if an electronic

More information

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board CE EMC Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board : Texas Instruments : WL1835MODCOM8B STANDARD : ETSI EN 301 489-1 V1.9.2

More information

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave. 1. MODEL: 23CR08FH-50ND 2 Dimension & Weight Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm Baffle Opening 20.1 φ mm Height Refer to drawing Weight 4.0Grams 3 Magnet Materials Rare Earth Size φ 9.5

More information

Jens-EMC ApS. Randersvej 6 DK-8600 Silkeborg Denmark. EMC test report 2010-01-11-SeaCom. AC48/SeaCom1000 & AC128/SeaCom2100

Jens-EMC ApS. Randersvej 6 DK-8600 Silkeborg Denmark. EMC test report 2010-01-11-SeaCom. AC48/SeaCom1000 & AC128/SeaCom2100 Jens-EMC ApS Randersvej 6 DK-8600 Silkeborg Denmark Test lab (+45) 86 84 91 66 Mobile(+45) 40 10 90 33 jko@jens-emc.dk www.jens-emc.dk CVR 27 21 47 62 EMC Consultancy EMC test report 2010-01-11-SeaCom

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

Teseq ESD Simulator Verification

Teseq ESD Simulator Verification Teseq ESD Simulator Verification Background Greg Senko, President Teseq Inc. North American division of Teseq Laboratory Technical Manager Edison NJ This presentation was first given in 2003 when lab was

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 2 Test Requirements for Electrical / Electronic Equipment and Systems Edition

More information

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide

More information

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE of Product Name Model Brand Memorex; Imation; TDK Life on Record Contains: 1. Declaration of Conformity 2. EN55022/CISPR 22, AS/NZS CISPR 22 EMI test

More information

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD FROM RFI GLOBAL SERVICES LTD Partial Test of: BTM411 To: EN 300 328 V1.7.1 (2006-10) Test Report Serial No: RFI/RPT1/RP76018JD01A This Test Report Is Issued Under The Authority Of Brian Watson, Operations

More information

30 In Compliance October 2014 www.incompliancemag.com

30 In Compliance October 2014 www.incompliancemag.com 30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,

More information

for Communication Systems Protection EMI CD-ROM INCLUDED

for Communication Systems Protection EMI CD-ROM INCLUDED Krešimir Malarić EMI Protection for Communication Systems CD-ROM INCLUDED Contents Preface xiii CHAPTER 1 Communications Systems 1 1.1 Components of Communications Systems 1 1.2 Transmitter Systems 2 1.2.1

More information

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01

RADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01 RADIO TEST REPORT SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range Report Reference No.... : G0M-1206-2043-TEU440G-V01 Testing Laboratory... : Eurofins Product Service GmbH Address...

More information

Model 3140. BiConiLog Antenna MANUAL EMC TEST SYSTEMS, L.P. MARCH 2002 REV C PN 399258

Model 3140. BiConiLog Antenna MANUAL EMC TEST SYSTEMS, L.P. MARCH 2002 REV C PN 399258 Model 3140 BiConiLog Antenna MANUAL EMC TEST SYSTEMS, L.P. MARCH 2002 MODEL 3140 BICONILOG ANTENNA EMC Test Systems, L.P. reserves the right to make changes to any product described herein in order to

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise

More information

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6

More information

Automatic Distance/Time Speedmeter Handbook (Second Edition) Provisional

Automatic Distance/Time Speedmeter Handbook (Second Edition) Provisional Automatic Distance/Time Speedmeter Handbook (Second Edition) Provisional A Guide to Type-Approval Procedures for Automatic Distance/Time Speedmeters Used for Road Traffic Law Enforcement in Great Britain

More information

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line

More information

Dual Chamber Temporary External Pacemaker

Dual Chamber Temporary External Pacemaker 5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

NMI M 6-2 Electricity Meters. Part 2: Test Report Format NMI M 6-2 Electricity Meters Part 2: Test Report Format Commonwealth of Australia 2010 First edition September 2010 National Measurement Institute Bradfield Road, Lindfield, NSW 2070 PO Box 264, Lindfield,

More information

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz

Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity

More information

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table Version MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity % meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz (5) - Sample

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers

More information

RX-AM4SF Receiver. Pin-out. Connections

RX-AM4SF Receiver. Pin-out. Connections RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate

More information

DATA SHEET DVI - HDCP Extension Cable

DATA SHEET DVI - HDCP Extension Cable DATA SHEET DVI - HDCP Extension Cable Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications

More information

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0. Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

T200, PTP/IEEE 1588 Grandmaster Clock and

T200, PTP/IEEE 1588 Grandmaster Clock and T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 1 HEOL-T200 : PERFORMANCE

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 BUREAU VERITAS ADT (SHANGHAI) CORPORATION 2F, Building C, No. 1618. Yishan Road 201103 Shanghai, CHINA Ms. Mary Gu (Authorized Representative) Phone: 86 21

More information

How To Read A Powerline From A Powerpoint Powerline To A Power Source

How To Read A Powerline From A Powerpoint Powerline To A Power Source Page: 2 of 71 Contents 1. Applicant information...3 2. Laboratory information...4 3. Test system configuration...5 3.1 Operation environment...5 3.2 Measurement Uncertainty...6 4. Description of E.U.T...7

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

NI USB-5681 RF Power Meter Specifications

NI USB-5681 RF Power Meter Specifications NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour

More information

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions PreCompliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions D. Schneider 1*, S. Tenbohlen 1, W. Köhler 1 1 Institute of Power Transmission and

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Design Guide for the Control of ESD in the esata Interface

Design Guide for the Control of ESD in the esata Interface Design Guide for the Control of ESD in the esata Interface Pat Young Principal Engineer Silicon Image, Steelvine Storage Products Scope This document is an informative design guideline only. It is intended

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Report No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894

Report No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894 Test Report Product Name All in one PC Model No. Transmitter Module. MSI / MS-6894 MS-6633, VS12489, NetOn AP1900 Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien,

More information

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION 1 SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION By Lannes S. Purnell FLUKE CORPORATION 2 This paper shows how standard signal generators can be used as leveled sine wave sources for calibrating oscilloscopes.

More information

For emission and immunity testing according to IEC 61000-4-20

For emission and immunity testing according to IEC 61000-4-20 EMC GTEM 500 Gtem Cell For emission and immunity testing according to IEC 61000-4-20 Theory of operation GTEM-cells (Giga-hertz Transversal Electro-Magnetic cells) are waveguide structures intended for

More information

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4

More information