1 Hz Ecocirc, EB, EBV, TLCB, TLCHB Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 97 Rev ev.a.a Ed./

2 Lowara is a trademark of Lowara srl Unipersonale, subsidiary of Xylem Inc. Ecocirc is a trademark of Laing Thermotec Inc, subsidiary of Xylem Inc. Xylect is a trademark of Xylem Water Solutions AB, subsidiary of Xylem Inc.

3 CONTENTS Product Range Chart... Ecocirc Series... 7 EB, EBV Series... TLCB Series... TLCHB Series...7 Installation Positions... Technical Appendix...

4 Ecocirc, EB, EBV,, TLCB, TLCHB SERIES PRODUCT RANGE CHART Version Power supply Pump coupling Temperature of pumped liquid Ambient temperature Protection class TYPE Single Twin Single-phase V Hz Single-phase - V / Hz Threaded Flanged + C + C - C + C Max C IP Ecocirc -/ Ecocirc -/ Ecocirc -/ Ecocirc -/ Ecocirc -/ Ecocirc -/8 Ecocirc -/ Ecocirc -/8 Ecocirc -/8 Ecocirc -/8 SANITARY EB -/ R EB -/ RU EB -/ R EB -/ RU EBV -/ EBV -/ U EBV -/ EBV -/ U EBV -/ EBV -/ TLCB -. TLCB - TLCB - TLCB - TLCB -.M TLCB -M TLCB -M TLCB -M TLCB -. TLCB - TLCB - TLCB -L TLCB -L TLCHB -7L TLCHB -8L TLCHB -L TLCHB -L TLCHB -7L TLCHB -8L TLCHB -L TLCHB -L ecocirc-modelli-en_a_sc

5 High efficiency circulators for domesting heating Ecocirc Series MARKET SECTORS RESIDENTIAL. APPLICATIONS Water circulation in heating and air conditioning systems. Refurbishment or extension of existing systems. Recommended for facilities fitted with thermostatic valves. Single-family houses or apartment buildings. Floor heating systems. SPECIFICATIONS PUMP Flow rate: up to, m /h. Head: up to,7 m. Maximum power consumption: W (for the m model) and W (for the m model). Temperature of pumped liquid: - C + C. Avoid condensation and ice formation. Maximum % glycol and water mixture. For glycol quantities higher than %, hydraulic performances must be checked. Maximum operating pressure: bar (PN ). Rotor assembly group: made of stainless steel/composite material/carbon. *) ErP ready L'alta efficienza del domani è disponibile adesso: i nuovi circolatori Ecocirc sono conformi alla Direttiva ErP per il MOTOR Permanent magnet EC (Electronically Commutated) type motor with spherical rotor/stator. Wet rotor with a single spherical ceramic/carbon bearing. Integrated motor protection; no external protection required. Single-phase - V / Hz power supply. Variable-speed motor, with automatic speed adjustment based on system requirement. Insulation class F ( C). Protection class IP. *) model -/ excluded.

6 Ecocirc Series CONSTRUCTION CHARACTERISTICS Improved hydraulics to improved efficiency: The very latest computer simulations have further optimized the pump housing and the impeller. The cast iron pump housing is cataphoresis coated completely and is therefore resistant to corrosion. The spherical rotor. The permanent magnet rotor/impeller unit is the only moving part. Spherical motor pumps are shaftless, and therefore whisper quiet over the whole lifetime. In case of an indicated rotor blocking, emergency software shakes and vibrates the rotor to avoid further blocking. The revolutionary Anti-Block-Technology allows to separate the magnetic chamber from the flow, preventing magnetite and sludge to block and damage the pump. Blocking up, even in very old, open systems is impossible by our pump design. Easy to control, Two in one control: Step-less manually control with constant speed, displayed by a white LED, or alternatively automatic differential pressure, displayed by a blue LED. Optimized motor technology: Doubled electric windings combined with the latest Bit processor technology - that also makes the Ecocirc even more efficient. Overtemperature protection feature that slows down the circulator in case the temperature of the electronic module is too high and shuts it down when temperature rises above the safety limit. The circulator will automatically restart after having cooled down. Always easy to access: The screw ring design results in a pump motor that can be rotated in any position around the circle. The electrical connection as well as the control knob is therefore easy to access. metres length three cores cable (G.7) for connection to the single-phase power source. Automatic air purge: Quick automatic air-venting-mode for a safe operation. According to EN standards -, --, -, -, 97-, 97-. CONTROL MODES Automatic regulation: the pump automatically adjusts the working conditions based on the requirement of the system. When the pump detects a decrease in the flow, the inverter reduces the differential pressure of the pump until it reaches the required head. ACCESSORIES SORIES Pipe unions. Insulation shell. INSTALLA ALLATION Suitable for installation in vertical or horizontal piping, in this last case not with the motor housing upward.

7 Ecocirc SERIES IDENTIFICATION TION CODE Ecocirc / PORT TO PORT DISTANCE IN mm. MAXIMUM HEAD IN m. PORT NOMINAL DIAMETER SERIES NAME EXAMPLE : Ecocirc -/ Electronic circulator of the Ecocirc series, port nominal diameter =, max head = m, with port to port distance mm. Ecocirc MATERIAL TABLE TABLE OF MATERIALS PART MATERIAL Pump body Rotor assembly group Bearing Gaskets Motor housing Screw ring Cast iron ( EN-GJL- ) cataphoretically coated Stainless steel Composite material Carbon Ceramics EPDM Rubber Aluminum ( AlSiCu ) Aluminum ( AlMgSi ) ecocirc--en_a_tm Regulations (EC) n. /9 and (EU) n. / Annex I point (Product information requirements) a) Energy efficiency index: see the EEI column in the tables in the Hydraulic performance section. b) The benchmark for most efficient circulators is EEI,. c) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. d) Information for circulators specifically designed to potable water uses: note not applicable to these products. 7

8 Ecocirc.../ SERIES TABELLA DI PRESTAZIONI IDRAULICHE CIRCOLATORI SERIE Ecocirc.. (Costante) HYDRAULIC PERFORMANCE TABLE (CONSTANT SPEED) PUMP POWER SPEED Q = DELIVERY TYPE EEI ABSORBED l/s,,,7,,8,,,,9 MIN MAX m /h,,,,8,,,,, V Hz () W W H = TOTAL HEAD METRES COLUMN OF WATER Ecocirc -/ Ecocirc -/ Ecocirc -/ Ecocirc -/8 Ecocirc -/8,,,,, min max,,,,,9,7,,,8, Performances according to standards EN 97-. () Energy efficiency index. ecocirc-c--en_b_th,,,,,, TABELLA DI PRESTAZIONI IDRAULICHE CIRCOLATORI SERIE Ecocirc.. (Proporziona (PROPORTIONAL PRESSURE) SURE) PUMP POWER CURRENT SPEED Q = DELIVERY TYPE EEI ABSORBED ABSORBED l/s,,,7,,8,,,,9 V Hz () W W A A MIN MAX MIN MAX m /h,,,,8,,,,, H = TOTAL HEAD METRES COLUMN OF WATER, Ecocirc -/ Ecocirc -/ Ecocirc -/ Ecocirc -/8 Ecocirc -/8,,,,,,9,8 min max,,,,9,,7,9,,,,9,,,,7,8, Performances according to standards EN 97-. () Energy efficiency index. ecocirc-p--en_b_th SINGLE-PHASE OPERATING CHARACTERISTICS Ecocirc -/ Ecocirc -/8 Ecocirc -/ Ecocirc -/8 Ecocirc -/ EN 97- Ecocirc -/ Ecocirc -/8 Ecocirc -/ Ecocirc -/8 Ecocirc -/ EN 97-8 Q [Imp gpm] 8 Q [Imp gpm] 8 Q [US gpm] 7 8 Q [US gpm] 7 8 P [W] 8 P [W] Q [m /h]..... Q.8[l/s] 98_E_CH Q [m /h]..... Q.8[l/s] 98_E_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec. Pump operates steplessly. Lines correspond to knob settings and are for reference only. 8

9 Ecocirc.../ SERIES DIMENSIONS AND WEIGHTS DIMENSIONS DIMENSIONI E PESI AND CIRCOLATORI WEIGHTS SERIE TABLE Ecocirc poli Hz PUMP TYPE DIMENSIONS (mm) WEIGHT H H D F DN kg Ecocirc -/ Rp /" G ",9 Ecocirc -/ Rp /" G "¼, Ecocirc -/ Rp " G "½, Ecocirc -/8 8 9 Rp " G "½, Ecocirc -/8 8 9 Rp "¼ G ", ecocirc-p-en_a_td 9

10 Ecocirc.../ SERIES TABELLA DI PRESTAZIONI IDRAULICHE CIRCOLATORI SERIE Ecocirc.. (Costante) HYDRAULIC PERFORMANCE TABLE (CONSTANT SPEED) PUMP POWER SPEED Q = DELIVERY TYPE EEI ABSORBED l/s,,,7,,,,,9,89 MIN MAX m /h,,,,8,,,,, V Hz () W W H = TOTAL HEAD METRES COLUMN OF WATER Ecocirc -/ Ecocirc -/ Ecocirc -/ Ecocirc -/8 Ecocirc -/8,*,,,, min,,,,,, max,9,,,,7,,,, Performances according to standards EN 97-. () Energy efficiency index. * ErP ready ecocirc-c--en_b_th TABELLA DI PRESTAZIONI IDRAULICHE CIRCOLATORI SERIE Ecocirc.. (Proporziona (PROPORTIONAL PRESSURE) SURE) PUMP POWER CURRENT SPEED Q = DELIVERY TYPE EEI ABSORBED ABSORBED l/s,,,7,,8,,,9,8 MIN MAX MIN MAX m/h,,,,8,,,,, V Hz () W W A A H = TOTAL HEAD METRES COLUMN OF WATER,9 Ecocirc -/ Ecocirc -/ Ecocirc -/ Ecocirc -/8 Ecocirc -/8,*,,,,,9,7 min max,,,,8,9,8,,,,7,,8,,7,9,, Performances according to standards EN 97-. () Energy efficiency index. * ErP ready ecocirc-p--en_b_th SINGLE-PHASE OPERATING CHARACTERISTICS Ecocirc -/ Ecocirc -/8 Ecocirc -/ Ecocirc -/8 Ecocirc -/ EN 97- Ecocirc -/ Ecocirc -/8 Ecocirc -/ Ecocirc -/8 Ecocirc -/ EN 97-8 Q [Imp gpm] 8 Q [Imp gpm] 8 Q [US gpm] 7 8 Q [US gpm] 7 P [W] 7 P [W] Q [m /h] Q [l/s] 98_E_CH Q [m. /h] Q [l/s] 98_E_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec. Pump operates steplessly. Lines correspond to knob settings and are for reference only.

11 Ecocirc.../ SERIES DIMENSIONS AND WEIGHTS DIMENSIONS DIMENSIONI E PESI AND CIRCOLATORI WEIGHTS SERIE TABLE Ecocirc poli Hz PUMP TYPE DIMENSIONS (mm) WEIGHT H H D F DN kg Ecocirc -/ Rp /" G ",9 Ecocirc -/ Rp /" G "¼, Ecocirc -/ Rp " G "½, Ecocirc -/8 8 9 Rp " G "½, Ecocirc -/8 8 9 Rp "¼ G ", ecocirc-p-en_a_td

12

13 High efficiency electronic sanitary circulators MARKET SECTORS RESIDENTIAL. APPLICATIONS Hot water circulation. EB, EBV Series SPECIFICATIONS PUMP Flow rate: up to m /h. Head: up to m. Temperature of pumped liquid: + C + C. Avoid condensation and ice formation. Maximum operating pressure: bar (PN ). Rotor assembly group: made of stainless steel/composite material/carbon. MOTOR Permanent magnet EC (Electronically Commutated) type motor with spherical rotor/stator. Wet rotor with a single spherical ceramic/carbon ball bearing. Integrated motor protection; no external protection required. Single-phase -V / Hz power supply. Motor type: - Fixed speed for temperature sensor and temperature sensor + timer models; - Variable speed with automatic regulation for basic and timer models. Insulation class F ( C). Protection class: IP no-timer models. IP timer models.

14 EB, EBV Series CONSTRUCTION CHARACTERISTICS Electric circulator pumps for domestic hot water applications at maximun temperature of C, at maximum hardness of f ( dh). Brassy pump body for direct installation onto piping for /" and /" - " /" threaded union connections. The design is based on spherical rotor/stator technology. This means that: - The only moving part is the spherical rotor/impeller unit that turns on a hard ceramic ball. - Shaft seals or conventional bearing bushings with a shaft have been eliminated for a single self realigning spherical bearing. Blockage free rotor: the spherical motor principle does not require a manual unblocking device thanks to the small touching surface of the bearing on the ball. The starting torque required is minimal. Models available: - Fixed speed (EB.. models) Temperature sensor to maintain the water onto piping at the required temperature. The circulator automatically turns off when the water temperature achieves the value. Temperature can be set up between C and 7 C by the selector on the motor. Temperature sensor and timer for more energy saving. - Variable speed (EBV.. models): Performances optimized by system requests. Speed set up is done by a selector on the motor by 7 different positions. At and positions (ECO) the consumption is especially low. Timer as a standard in order to daily set up the performances. mm port-to-port length models are fitted out with non-return and shut off valve. mm port-to-port length models are fitted out with a non-return valve to install to supply connection. According to EN standards -, --, -, -. ACCESSORIES SORIES Pipe unions. Insulation shell. INSTALLA ALLATION Suitable for installation in vertical or horizontal piping, in this last case not with the motor housing upward.

15 EB, EBV SERIES IDENTIFICATION TION CODE EB V / R U NULL = NO TIMER U = WITH TIMER NULL = NO TEMPERATURE SENSOR R = WITH TEMPERATURE SENSOR PORT TO PORT DISTANCE IN mm. MAXIMUM HEAD IN m. PORT NOMINAL DIAMETER NULL = FIXED SPEED V = VARIABLE SPEED SERIES NAME EXAMPLE : EB -/ RU Electronic circulator of the EB series, port nominal diameter =, max head = m, port to port distance mm, with temperature probe and timer. TABELLA MATERIALI EA TABLE OF MATERIALS PART MATERIAL Pump body Rotor assembly group Bearing Gaskets Brass Stainless steel Composite material Carbon Ceramic EPDM eb--en_b_tm Regulations (EC) n. /9 and (EU) n. / Annex I point (Product information requirements) a) Energy efficiency index: note not applicable to these products. b) The benchmark for most efficient circulators is EEI, : note not applicable to these products. c) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. d) Information for circulators specifically designed to potable water uses: This circulator is suitable for drinking water only.

16 EB, EBV SERIES HYDRAULIC TABELLA DI PRESTAZIONI PERFORMANCE IDRAULICHE TABLE CIRCOLATORI SERIE EB Monofase Hz PUMP POWER SPEED Q = DELIVERY TYPE ABSORBED l/s,,,8,,,9,,8,,9 MIN MAX m /h,,,,,,7,8,, V Hz W W H = TOTAL HEAD METRES COLUMN OF WATER EB -/ R,9 7, max,,,,9,8,7,, EB -/ RU 7, 9, max,,,,9,8,7,, EB -/ R,8 7, max,,9,8,9,,9 EB -/ RU 7, 8,8 max,,9,8,9,,9 EBV -/ EBV -/ U EBV -/ EBV -/ U EBV -/ EBV -/,,,,7,,,7,,,8,, min min min min min min,,,,,,,8,8,,,,,,,,,9 7,,8 7, 7, 7, 7, 9, 7, 8,8,7, max max max max max max,,,,,,,,,9,9,9,,,,8,8,8,8,9,9,9,9,7,9,8,8,,,,8,7,7,9,9,,7,,,,,,,,8,97,9,9,89 Hydraulic performances in compliance with ISO 99: - Grade B (ex ISO 99:999 - Annex A) eb--en_e_th

17 EB SERIES SINGLE-PHASE OPERATING CHARACTERISTICS EB -/ R ISO 99: - Grade B EB -/ RU ISO 99: - Grade B Q [Imp gpm] Q [Imp gpm] Q [US gpm]. Q [US gpm] P [W] P [W] Q [m /h] Q [l/s] 98_D_CH Q [m /h] Q [l/s] _C_CH EB -/ R ISO 99: - Grade B EB -/ RU ISO 99: - Grade B.... Q.[Imp gpm].... Q.[Imp gpm]..... Q [US. gpm] Q [US. gpm] P [W] P [W] Q [m /h]..... Q [l/s] 98_D_CH Q [m /h]..... Q [l/s] _C_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec. 7

18 EBV SERIES SINGLE-PHASE OPERATING CHARACTERISTICS * EBV -/ ISO 99: - Grade B * EBV -/ ISO 99: - Grade B Q [Imp gpm].... Q.[Imp gpm] Q [US gpm] Q [US. gpm] P [W] 7 P [W] Q [m /h] Q [l/s] _C_CH Q [m /h]..... Q [l/s] _C_CH * EBV -/ U ISO 99: - Grade B * EBV -/ U ISO 99: - Grade B Q [Imp gpm].... Q.[Imp gpm] Q [US gpm] Q [US. gpm] P [W] 8 7 P [W] Q [m /h] Q [l/s] _C_CH Q [m /h]..... Q [l/s] _C_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec. * Pump operates steplessly. Lines correspond to knob settings and are for reference only. 8

19 EBV SERIES SINGLE-PHASE OPERATING CHARACTERISTICS * EBV -/ ISO 99: - Grade B * EBV -/ ISO 99: - Grade B Q [Imp gpm] Q [Imp gpm].. Q [US gpm] Q [US gpm] P [W] Q [m /h] Q [l/s] 98_C_CH... P [W] Q [m /h]..... Q [l/s] _B_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec. * Pump operates steplessly. Lines correspond to knob settings and are for reference only. 9

20 EB, EBV SERIES DIMENSIONS AND WEIGHTS DIMENSIONI E PESI CIRCOLATORI SERIE EB(V) poli Hz DIMENSIONS AND WEIGHTS TABLE PUMP TYPE DIMENSIONS (mm) A A B B C C DN kg EB -/R EBV -/ ,9 EB -/RU EBV -/U EB -/R EBV -/ , EB -/RU EBV -/U , EBV -/ ,9 EBV -/ , PESO eb-p-en_d_td

21 Sanitary Circulators MARKET SECTORS RESIDENTIAL. APPLICATIONS Circulation of sanitary hot water. TLCB Series SPECIFICATIONS PUMP Flow rate: up to m /h. Head: up to m. Temperature of pumped liquid: + C + C. Avoid condensation and ice formation. Maximum operating pressure: bar (PN ). Impeller: made of composite material. Wear ring: ceramic. MOTOR Wet rotor type, with bearings lubricated by the pumped liquid. Axial and radial bearings made of ceramic. Single-phase V Hz power supply. Terminal box axially integrated in the motor. Three speed hand selector motor. Insulation class 8 (H). Protection class IP. CONSTRUCTION CHARACTERISTICS Electric circulator pumps for sanitary hot water circulation, at a maximum temperature of C, maximum hardness of f ( dh) and maximum viscosity of mm /S. Bronze pump body designed for direct installation onto copper piping, with ", " ¼ and " ½ threaded connections. According to EN standards -, --, -, -. ACCESSORIES SORIES Pipe unions. Insulation shell. INSTALLA ALLATION Suitable for installation in horizontal or vertical piping, in any position provided that motor axis is horizontal.

22 TLCB SERIES IDENTIFICATION TION CODE TLC B L PORT TO PORT DISTANCE NULL = mm M = mm L = 8 mm MAXIMUM HEAD IN m. PORT NOMINAL DIAMETER B = BRONZE VERSION SERIES NAME EXAMPLE : TLCB -L TLC series circulator, bronze B version, port nominal diameter =, max head= m, with port to port distance of 8 mm. TABELLA MATERIALI TLCB TABLE OF MATERIALS PART MATERIAL Pump body Impeller Shaft Inner jacket Wear ring Bearings Gaskets Bronze Composite material Ceramics Stainless steel Ceramics Ceramics EPDM tlcb-p-en_a_tm Regulations (EC) n. /9 and (EU) n. / Annex I point (Product information requirements) a) Energy efficiency index: note not applicable to these products. b) The benchmark for most efficient circulators is EEI, : note not applicable to these products. c) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. d) Information for circulators specifically designed to potable water uses: This circulator is suitable for drinking water only.

23 TLCB SERIES HYDRAULIC TABELLA DI PRESTAZIONI PERFORMANCE IDRAULICHE TABLE CIRCOLATORI SERIE TLCB poli Hz PUMP MAXIMUM MAXIMUM CAPACITOR SPEED Q = DELIVERY TYPE ABSORBED ABSORBED l/s,,,,,7,8,, POWER CURRENT m /h,,,,8,,,, V Hz W A µf V H = TOTAL HEAD METRES COLUMN OF WATER TLCB -. 8,,,8,, TLCB -.M,,,,,, TLCB -. 8,8,,,8,, TLCB -,7,,, TLCB -M 8,,,,7,,8, TLCB -,,,7,,,7, TLCB -,9,,,,9,, TLCB -M 9,8,,,,9,7,,8, TLCB - (L) 7,,,8,,,,,, TLCB -,7,,9,,9, TLCB -M 8,7,,7,,7,,9,,7 TLCB -L,,,,,,7,,,8, Hydraulic performances in compliance with ISO 99: - Grade B (ex ISO 99:999 - Annex A) tlcb-p-en_c_th

24 TLCB SERIES SINGLE-PHASE OPERATING CHARACTERISTICS TLCB -. TLCB -.M TLCB -. ISO 99: - Grade B TLCB - TLCB - M TLCB - ISO 99: - Grade B Q [Imp gpm] Q [Imp gpm] 8 Q [US gpm]. 8 Q [US gpm] Q [m /h] Q [l/s] 7_C_CH Q [m /h]..... Q.8 [l/s] 7_C_CH TLCB - TLCB - M TLCB - TLCB - L ISO 99: - Grade B TLCB - TLCB - M TLCB - L ISO 99: - Grade B Q [Imp gpm] Q [Imp gpm] Q [US gpm] Q [US gpm] 8 Q [m /h].... Q.8 [l/s] 7_C_CH Q [m /h]... Q [l/s] 7_C_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec.

25 TLCB SERIES DIMENSIONS AND WEIGHTS DIMENSIONI E PESI CIRCOLATORI SERIE TLCB poli Hz DIMENSIONS AND WEIGHTS TABLE PUMP TYPE DIMENSIONS (mm) WEIGHT H H D F DN kg TLCB -. /" G ",9 TLCB -.M 7 /" G "¼ TLCB -. " G "½ TLCB - /" G ",9 TLCB -M 7 /" G "¼ TLCB - " G "½ TLCB - /" G ",9 TLCB -M 7 /" G "¼ TLCB - " G "½ TLCB -L 8 9 " G "½, TLCB - /" G ",9 TLCB -M 7 R¾ G "¼ TLCB -L 8 9 R G "½, tlcb-p-en_c_td

26

27 Sanitary Circulators MARKET SECTORS SANITARY LIGHT COMMERCIAL. APPLICATIONS Circulation of sanitary hot water in high flow/high head installations. TLCHB Series SPECIFICATIONS PUMP Flow rate: up to m /h. Head: up to m. Temperature of pumped liquid: + C + C. Avoid condensation and ice formation. Maximum operating pressure: bar (PN ). Impeller: made of composite material. Wear ring: ceramic. MOTOR Wet rotor type, with bearings lubricated by the pumped liquid. Axial and radial bearings made of ceramic. Single-phase V Hz power supply. Terminal box axially integrated in the motor. Three speed hand selector motor. Insulation class 8 (H). Protection class IP. CONSTRUCTION CHARACTERISTICS Electric circulator pumps for sanitary hot water circulation, at a maximum temperature of C, maximum hardness of f ( dh) and maximum viscosity of mm /S. Bronze pump body designed for direct installation onto copper piping, with " ¼ and " ½ threaded connections. According to EN standards -, --, -, -. ACCESSORIES SORIES Pipe unions. Insulation shell. INSTALLA ALLATION Suitable for installation in horizontal or vertical piping, in any position provided that motor axis is horizontal. 7

28 TLCHB SERIES IDENTIFICATION TION CODE TLC H B 8 L PORT TO PORT DISTANCE 8 mm MAXIMUM HEAD IN m. PORT NOMINAL DIAMETER B = BRONZE VERSION H = HIGH FLOW / HIGH HEAD SERIES NAME EXAMPLE : TLCHB -8L TLC series circulator, high flow/head H version, bronze B version, port nominal diameter =, max head= 8 m, with port to port distance of 8 mm. TABELLA MATERIALI TLCHB TABLE OF MATERIALS PART MATERIAL Pump body Impeller Shaft Inner jacket Wear ring Bearings Gaskets Bronze Composite material Ceramics Stainless steel Ceramics Ceramics EPDM tlchb-p-en_a_tm Regulations (EC) n. /9 and (EU) n. / Annex I point (Product information requirements) a) Energy efficiency index: note not applicable to these products. b) The benchmark for most efficient circulators is EEI, : note not applicable to these products. c) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. d) Information for circulators specifically designed to potable water uses: This circulator is suitable for drinking water only. 8

29 TLCHB SERIES HYDRAULIC TABELLA DI PRESTAZIONI PERFORMANCE IDRAULICHE TABLE CIRCOLATORI SERIE TLCHB poli Hz PUMP MAXIMUM MAXIMUM CAPACITOR SPEED Q = DELIVERY TYPE ABSORBED ABSORBED l/s,,7,,,7,,,7 POWER CURRENT m /h,,,,8, 7, 8, 9, V Hz W A µf V H = TOTAL HEAD METRES COLUMN OF WATER TLCHB -7L TLCHB -7L TLCHB -8L TLCHB -8L TLCHB -L TLCHB -L TLCHB -L TLCHB -L,,8,,,,9, 8, 8,,7,,,,,,, 7,,7,,,,,,,,,9,7,,8,8 7, 8, 7, 7,,,,9,7,7 8, 8, 7,,9,9,8,7,7,7 8, 8, 7,,,7,, 8, 9, 8,7 7,7,,,,7 7,, 9, 8,8 7,7,,,8,, 8, 7,8,,,,7 7,9 8,, 9, 8,,9,,,9,7,9,, 9, 7,7,,7,, Hydraulic performances in compliance with ISO 99: - Grade B (ex ISO 99:999 - Annex A) tlchb-p-en_d_th 9

30 TLCHB SERIES SINGLE-PHASE OPERATING CHARACTERISTICS TLCHB - 7L TLCHB - 7L ISO 99: - Grade B TLCHB - 8L TLCHB - 8L ISO 99: - Grade B Q [Imp gpm] Q [Imp gpm] Q [US gpm] 8 Q [US gpm] Q [m /h] Q [l/s] 7_D_CH 8 Q [m /h] Q [l/s] 7_D_CH TLCHB - L TLCHB - L ISO 99: - Grade B TLCHB - L TLCHB - L ISO 99: - Grade B Q [Imp gpm] Q [Imp gpm] Q [US gpm] Q [US gpm] Q [m /h] Q [l/s] 7_D_CH 8 Q [m /h] Q [l/s] 7_D_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec.

31 TLCHB SERIES DIMENSIONS AND WEIGHTS DIMENSIONI E PESI CIRCOLATORI SERIE TLCHB poli Hz DIMENSIONS AND WEIGHTS TABLE PUMP TYPE DIMENSIONS (mm) WEIGHT H H D F DN kg TLCHB -7L 8 9 /" G "¼,7 TLCHB -7L 8 9 " G "½,7 TLCHB -8L 8 9 /" G "¼,7 TLCHB -8L 8 9 " G "½,7 TLCHB -L 8 9 /" G "¼,7 TLCHB -L 8 9 " G "½,7 TLCHB -L 8 9 /" G "¼,7 TLCHB -L 8 9 " G "½,7 tlchb-p-en_c_td

32 Ecocirc SERIES INSTALLA ALLATION POSITIONS EB, EBV SERIES TLCB, TLCHB SERIES

33 TECHNICAL APPENDIX

34 TENSIONE DI VAPORE VAPOUR PRESSURE SURE TABELLA TENSIONE DI VAPORE ps E DENSITA' DELL'ACQUA VAPOUR PRESSURE SURE ps AND ρ DENSITY OF WATER TABLE t T ps ρ t T ps ρ t T ps ρ C K bar kg/dm C K bar kg/dm C K bar kg/dm 7,,,9998 8,,7,987 9,,98,99 7,,7,9999 9,,,98 9,,,9 7,,7,9999 7,,7,98 97,,,99 7,,78,9999 8,,87,98 99,,9,979 77,,8, 9,,9,987 8,,,9 78,,87,,,99,98,,7,9 79,,9,,,8,98,,87,98 7 8,,,9999,,8,98 7,,,9 8 8,,7,9999,,8,98 9,,,99 9 8,,7,9998 7,,9,98 8,,,97 8,,7,9997 8,,,98,,,98 8,,,9997 9,,,9799 8,,,9 8,,,999 7,,7,979 8,,,9 8,,97,999 8,,8,9788,,8,97 87,,97,999 9,,98,978 8, 7,8,9 88,,7,999 7,,,9777 7, 7,9,897 89,,87,999 7,,, , 8,9,89 7 9,,9,9988 7,,9,97 8,,7, ,,,9987 7,,,97 8 8,,,88 9 9,,9, ,,9,97 9,,,87 9,,7, ,,8, ,,987,87 9,,8, ,,9,97 7,,,87 9,,, ,,89,97 78, 7,,888 9,,88,997 78,,,979 8, 9,77,88 97,,98,997 79,,7,97 88,,,87 98,,,997 8,,7,97 9,,98,8 99,,,998 8,,9,97 98,,,89 7,,,99 8,,,97, 7,97,87 8,,778,99 8,,,997 8,,,8 9,,,99 8 7,,7,99,,78,8,,, ,,78,98 8,,,8,,9,99 8 9,,,978, 9,77,799,,7,99 87,,9,97 8,,,79,,9,997 88,,9,9,,9,789 7,,8,99 89,,79,98 8,,877,779 8,,,99 9,,7,9 7,,8,778 9,,9,997 9,,78,9 7 8, 9,9,79 7,,7,99 9,,7,98 8,,,7 8,,,99 9,,789,9 8 8, 9,8,7 9,,99, ,,8,9 9, 7,,7,,77,99 9 8,,8,9 9 8, 8,7,7,,7777, ,,879,9 7, 8,97,7,,898, ,,99,9 78, 9,,77,,99, ,,9,99 8, 98,7,9 7,,9, ,,977,98 88,,,79 8,,98,99 7,,,98 9,,89,9 9,,8,9898 7,,878,97 98,,, 7,,,989 77,,8,9, 8,, 8,,, ,,,97,,, 9,,7, ,,9,9,,,7,,,988 8,,7,97, 8,7,7,,9,987 8,,,99 7,,,8,,,987 87,,,97 7, 7,,,,,9,98 89,,7,9 7,,,98 8 9,,88,9 G-at_npsh_b_sc TECHNICAL APPENDIX

35 TABLE OF FLOW RESISTANCE IN m OF STRAIGHT CAST IRON PIPELINE (HAZEN-WILLIAMS FORMULA C=) FLOW RATE NOMINAL DIAMETER in mm and inches m /h l/min 8 7 /" /" " /" /" /" " " " " 7" 8" " " " ", v,9,,,, hr,9,,, The hr values must be multiplied by:,9 v,,8,,,,7 for galvanized or painted steel pipes hr,9 8,,8,8,9, for stainless steel or copper pipes, v,89,,8,,7,7,7 for PVC or PE pipes hr 7,7,,79,,9,, v,,,8,,, hr 87,, 7,,8,7,,8 v,8,9,,,, hr,,,,,, v,,8,9,7,, hr,,,,7,, v,,,8,,, hr, 7,,9,7,9, v,,7,,,, hr 77,, 7,8,,89,, v,8,,,8,, hr 8,,,7,,, 7 v,7,8,,9,9, hr 8,7,,9,,,8 8 v,,7,,,8, hr 8, 8,7,,,9, 9 v v,,,87,7,9,,7,8,,,, hr hr 77, 9,, 8, 7,8 9,,,,7,9,7, 7, v,,9,,,, hr,8,,8,,9 9 v,,99,7,7,, hr 9,9,,8,9,9,, 7 v,,,9,88,8,7 hr 79,7,9 9,7,,9, v,,,7,,, hr,,,,8, 8 v v,8,98,,,,,,,8,,,, hr hr 7,8,, 7,,8,89,9,78,8,,8, v v v,,,,,,,,,99,,,7,8,,8,,8,7,8,7, hr hr hr 87 88,,8,,7, 7, 8,98,,,,,,,8,7,,,, 7 v,9,,,9,9,,9 hr 8,8,9,,,, v v,79 7,,,,,99,7,9,9,,7,8,, hr hr 88,,, 9,,,,7,,7,89,, v,,,,,9,9, hr,, 7,79,,8,,7 7 v,8,,,7,8,87, hr 9,,9,8,97,,77, 9 v 7,,98,8,,,,8 hr 8,9,,7,9,8, 7 v 8,79,8,7,8,,,9 hr 79,,9 7,,,,7 v,,,7,89,9,,8 hr 8, 8, 9,8,9,8,9, v 8,9,,,,7,,8 hr,,,89,78,,9 8 v,7,8,8,8,9,,7 hr 9,, 8,,9,,9,8 v 7,,7,,,8,9,8 hr 79,,7,,8,7,9,8 v 8,9,,77,77,,,9 hr,,,,,7,8 v,79,7,7,,7,8 hr,,,,,77,7 v 8,,,,8,, hr 7, 9,8, 7,,7, 7 v,,8,7,8,, hr 9, 8,7 9,7,9,, v v 7, 8,9,,,,78,7,,89,,9,,9 hr hr,7,,9 9,8,9,,,,7,,8,, G-at-pct-en_a_th v,9,,,,7, hr, 8,9,,,, hr = flow resistance for m of straight pipeline (m) V = water speed (m/s) TECHNICAL APPENDIX

36 FLOW RESISTANCE TABLE OF FLOW RESISTANCE IN BENDS, VAL ALVES AND GATES The flow resistance is calculated using the equivalent pipeline length method according to the table below: TABELLA LUNGHEZZA DI TUBAZIONE EQUIVALENTE ACCESSORY TYPE 8 Equivalent pipeline length (m) bend,,,,,,,9,,,9,,8 9 bend,,,9,,,,,,,9,7,8 9 smooth bend,,,,,9,,,7,9,8,,9 Union tee or cross,,,7,,,,,, 7,,7,8 Gate - - -,,,,,,,9,, Non return valve,,,9,,,,7,9 7, 9,,8,9 DN G-a-pcv-en_a_th The table is valid for the Hazen Williams coefficient C= (cast iron pipework); for steel pipework, multiply the values by,; for stainless steel, copper and coated cast iron pipework, multiply the values by,8; When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of flow resistance. The values given are guideline values which are bound to vary slightly according to the model, especially for gate valves and non-return valves, for which it is a good idea to check the values supplied by manufacturers. TECHNICAL APPENDIX

37 VOLUMETRIC CAPACITY ACITY Litres Cubic metres Cubic feet Cubic feet Imp. gal. US gal. per minute per hour per hour per minute per minute per minute l/min m /h ft /h ft /min Imp. gal/min Us gal./min,,,89,,,,7,,7,88,,9,79,8,,7,8,7 8,8,99,,,88 7,8,,78 9,,,,9,78,7 8,8,7,87, PRESSURE SURE AND AND HEAD HEAD Newton per kilo Pascal bar Pound force per metre millimetre of square metre square inch of water mercury N/m kpa bar psi m H O mm Hg,, x -. x -. x -,7,,,,, 7, x,,,8,97 7,8 89,77,898,89,,7,7 98, 9,87,98,, 7,,,,,9,, LENGTH millimetre centimetre metre inch foot yard VOLUME mm cm m in ft yd,,,,9,,,,,,97,8,9,,, 9,7,88,9,,,,,8,78,8,8,8,,, 9, 9,,9,,, cubic metre litre millilitre imp. Gallon US gallon cubic foot m litro ml imp. gal. US gal. ft,, x 9,99,7,7,,,,,, x -,,. x -. x -. x -,,,87,,9,,8,78 78,,87,,7,8 8,8 8,8,88 7,8, G-at_pp-en_a_sc 7 TECHNICAL APPENDIX

38 FURTHER PRODUCT SELECTION AND DOCUMENTATION TION Xylect TM Xylect TM is pump solution selection software with an extensive online database of product information across the entire Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara and Vogel products. The search can be made by: Application Product type Duty point Xylect TM gives a detailed output: List with search results Performance curves (flow, head, power, efficiency, NPSH) Motor data Dimensional drawings Options Data sheet printouts Document downloads incl dxf files The search by application guides users not familiar with the product range to the right choice. TECHNICAL APPENDIX 8

39 FURTHER PRODUCT SELECTION AND DOCUMENTATION TION Xylect TM The detailed output makes it easy to select the optimal pump from the given alternatives. The best way to work with Xylect TM is to create a personal account. This makes it possible to: Set own standard units Create and save projects Share projects with other Xylect TM users Every user have a My Xylect space, where all projects are saved. For more information about Xylect TM please contact our sales network or visit Dimensional drawings appear on the screen and can be downloaded in dxf format. 9 TECHNICAL APPENDIX

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod.

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC. Cod. / Hz ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev ev.a.a Ed./ ecocirc BASIC SERIES INSTALLA ALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks

More information

65L, 95L, 120L, 160L, 250L, 320L

65L, 95L, 120L, 160L, 250L, 320L TECHNICAL BROCHURE B65-32L R1 65L, 95L, 12L, 16L, 25L, 32L 6" Stainless Steel Submersible s 6 HZ HIGH CAPACITY FOR 6" AND LARGER WELLS FEATURES Powered for Continuous Operation: All ratings are within

More information

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection

More information

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

VA / VB / VD WET ROTOR CIRCULATORS TECHNICAL DATA

VA / VB / VD WET ROTOR CIRCULATORS TECHNICAL DATA VA / V / V WET ROTOR CIRCUATORS VA V V TECNICA ATA Operating range: from. to 3, m3/h with head up to metres. Pumped liquid temperature range: from -1 C to +11 C. Pumped liquid: clean, free from solids

More information

QUOTATION Pagina 2 / 7

QUOTATION Pagina 2 / 7 14-9-15 QUOTATION Pagina 2 / 7 Via Marco Polo, 14-3535 Mestrino (PD), Italy Tel. +39 49 5125 - +39 49 512595 Ref. Art.-nr. Omschrijving Aant.Eenheidsprijs Totale lijstprijs SERIES EVOPLUS 1 615966 EVOPLUS

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL.

MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. Twin- Impeller Centrifugal Electric Pumps CA-CA(N) Series Standard supplied IE2 motors are compliant with Regulation (EC) no. 640/2009. MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. APPLICATIONS Version

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

Flygt 3068, 50Hz. Technical Specification

Flygt 3068, 50Hz. Technical Specification Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating

More information

Flygt 3057, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating

More information

VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS

VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS Vertical multistage centrifugal electric pumps stainless steel. APPLICATIONS Treating water Industrial washing systems Heating and air conditioning Water supply and boosting Agriculture Irrigation TECHNICAL

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw. Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year

More information

33GS, 40GS, 55GS, 60GS, 75GS & 80GS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS

33GS, 40GS, 55GS, 60GS, 75GS & 80GS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS TECHNICAL BROCHURE B33-8GS R1 FEATURES Powered for Continuous Operation: All ratings are within the working limits of the motor as recommended by the motor manufacturer. can be operated continuously without

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

SJT / SJM / SJP Large Vertical Pumps

SJT / SJM / SJP Large Vertical Pumps SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

MEMBRANE VACUUM MINI PUMPS

MEMBRANE VACUUM MINI PUMPS MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free

More information

LTU 401. Technical Specification

LTU 401. Technical Specification LTU 401 Technical Specification Table of Contents Table of Contents LTU 401 Submersible Level Sensor... 2 Product... 2 Features... 2 Technical Features... 2 Approvals and Standards...2 Electrical specification...

More information

SUBMERSIBLE PUMPS AFP 0831 to 2046

SUBMERSIBLE PUMPS AFP 0831 to 2046 SUBMERSIBLE PUMPS AFP 0831 to 2046 DIN/EN 12050-1 Robust, reliable sewage pumps from 1.3 to 22 kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and communal

More information

GRUNDFOS DATA BOOKLET CHI, CHIU. Multipurpose stainless steel pumps 50 Hz

GRUNDFOS DATA BOOKLET CHI, CHIU. Multipurpose stainless steel pumps 50 Hz GRUNDFOS DATA BOOKLET CI, CIU Multipurpose stainless steel pumps 5 z Contents General data Performance range, 5 z Page 3 Applications Page Pumped liquids Page Operating conditions Page Maximum operating

More information

Multistage Pumps. P, PVa, MP 300

Multistage Pumps. P, PVa, MP 300 Multistage Pumps P, PVa, MP 300 Technical Data Performance range: m Capacities up to 1800m 3 /h (8800USgpm) m Head up to 300m (1000feet) m Max. speed up to 1750rpm Multistage pumps of series MP with smaller

More information

3-Way Temperature Control Valve

3-Way Temperature Control Valve 3-Way Temperature Control Valve l G, Version G and Accessories Charge air cooling Secondary cooling systems Fuel and lube oil preheating Co-generation Engine jacket water GG valve Waste heat boilers Product

More information

Laing industrial pumps

Laing industrial pumps Laing industrial pumps... with spherical motor, robust and reliable! Normal suction centrifugal pumps! Self-priming pumps! Ecocirc DC pumps Summary Chapter Page Normal suction centrifugal pumps... 3 Application...

More information

SUBMERSIBLE PUMPS AFP 0831 to 2046

SUBMERSIBLE PUMPS AFP 0831 to 2046 SUBMERSIBLE UMS AF 0831 to 046 DIN/EN 1050-1 Robust, reliable sewage pumps from 1.3 to kw for pumping wastewater and sewage from buildings and sites in private, commercial, industrial and communal areas.

More information

50 Hz. HM..P - HM..S - HM..N e-hm TM Series THREADED HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS.

50 Hz. HM..P - HM..S - HM..N e-hm TM Series THREADED HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS. 5 Hz HM..P - HM..S - HM..N e-hm TM Series THREADED HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS ErP 29/125/EC Cod. 1913921 Rev. B Ed.11/213 e-hm SERIES HYDRAULIC PERFORMANCE

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

MATERIALS N PARTS MATERIALS SUBMERSIBLE PUMPS. 1 Handle Stainless steel (AISI 304) 2 Electric cable 07RN8-F. 3 Screws Stainless steel (AISI 304)

MATERIALS N PARTS MATERIALS SUBMERSIBLE PUMPS. 1 Handle Stainless steel (AISI 304) 2 Electric cable 07RN8-F. 3 Screws Stainless steel (AISI 304) FOR SEWGE TECNICL DT Impeller type: Vortex. Solid handling: 1 mm. Nominal power: 1,1 11. Outlet: DN / / 1. Perfomance range: from.3 to 1 m3/h with 1 meters head. Fluid: wastewater and sewage from buildings

More information

CR3-21 A-FGJ-A-E-HQQE 3x400D 50HZ

CR3-21 A-FGJ-A-E-HQQE 3x400D 50HZ GRUNDFOS DATA BOOKLET CR3-21 A-FGJ-A-E-HQQE 3x4D 5HZ Grundfos Pump 96513345 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96513345/cr-3-21-a-fgj-a-e-hqqe.html

More information

CR15-07 A-F-A-E-HQQE 3x400D 50 HZ

CR15-07 A-F-A-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CR15-7 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651898 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651898/cr-15-7-a-f-a-e-hqqe.html

More information

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

CR10-03 A-A-A-E-HQQE 3x230/400 50 HZ

CR10-03 A-A-A-E-HQQE 3x230/400 50 HZ GRUNDFOS DATA BOOKLET CR1-3 A-A-A-E-HQQE 3x23/4 5 HZ Grundfos Pump 965981 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/965981/cr-1-3-a-a-a-e-hqqe.html

More information

LAK DC Motors. LAK 4000 Series kw HP Nm. t-telectric.com. Catalogue-2008/11 E

LAK DC Motors. LAK 4000 Series kw HP Nm. t-telectric.com. Catalogue-2008/11 E LAK DC Motors Catalogue-2008/11 E LAK 4000 Series 112-280 1-500 kw 1-700 HP 30-4500 Nm t-telectric.com List of contents Introduction... p. 4 Options... p. 5 Application data... p. 6 Output data... p.

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06 SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz

More information

VARIABLE VANE PUMPS V3

VARIABLE VANE PUMPS V3 VARIABLE VANE PUMPS V3 (series 30 and 40) Nominal sizes 12; 25; 40; 63 up to p n 100 bar V g 8.5; 19; 32; 47 cm 3 /rev KE 1015 11/02 replaces 07/97 easy commissioning due to automatic bleed facility low

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

Technical data sheet S_Series S_300 Vacuum pump systems

Technical data sheet S_Series S_300 Vacuum pump systems Technical data sheet S_Series S_300 Vacuum pump systems General information 2BL2 501-0K Standard version for use in general industries 2BL2 501-0H version with external two-chamber preseparator with automatic

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

08.08 Vic-Check Valves

08.08 Vic-Check Valves The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc

More information

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125 Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125 Technical Data Performance range: m Capacities up to 340m 3 /h (1500USgpm) m Head up to 500m (1640feet) m Max. speed up to 3600rpm Multistage pumps

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01) VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

SUBMERSIBLE ELECTRIC PUMPS

SUBMERSIBLE ELECTRIC PUMPS SUBMERSIBLE ELECTRIC PUMPS SUBMERSIBLE PUMPS Gruppo Aturia started developing the Submersible Pump for pumping water in agriculture and for distribution of water in the municipalities. For these applications

More information

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right

More information

SIHI ISOchem. Modular Chemical Process Pumps. Type CBS, CBM, CBE. Technical Data. Construction. Applications. Design

SIHI ISOchem. Modular Chemical Process Pumps. Type CBS, CBM, CBE. Technical Data. Construction. Applications. Design Modular Chemical Process Pumps SIHI ISOchem Type CBS, CBM, CBE Technical Data Flow rate: max. 650 m³/h Head: max. 150 m Speed: max. 3600 min -1 Materials: Cast iron, cast steel, stainless steel, hastelloy,

More information

The conditions below apply to the curves shown on the following pages.

The conditions below apply to the curves shown on the following pages. GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29 _02 A centrifugal with a 12 in. diameter impeller requires a power input of 60 hp when the flowrate is 3200 gpm against a 60 ft head. The impeller is changed to one with a 10 in. diameter. Determine the

More information

Differential pressure sensors

Differential pressure sensors 1 923 1923P01 Differential pressure sensors for neutral or slightly aggressive gases and liquids QBE61.3-DP.. Operating voltage AC 24 V or DC 18...33 V Output signal DC 0...10 V Connecting male thread

More information

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following

More information

Model 222S (Galvanized receiver optional) AURORA. 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS

Model 222S (Galvanized receiver optional) AURORA. 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS Model 222S (Galvanized receiver optional) AURORA 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS WWW.AURORAPUMP.COM AURORA 220 Series Single Stage Condensate and Boiler Feed Pumps 2 Introduction

More information

Series DFMT Digital Paddlewheel Flowmeter

Series DFMT Digital Paddlewheel Flowmeter Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous

More information

Self Operated Pressure Control Valves 5953 and 5954

Self Operated Pressure Control Valves 5953 and 5954 Pagina 1 di 8 7C.400-E Ed. 6 IT - 2010 Self Operated Pressure Control Valves 5953 and 5954 Description Fluxotrol self operated pressure control valves are used for the pressure control of liquids, steam

More information

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves 1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire

More information

Flygt 3085, 50Hz. Technical Specification

Flygt 3085, 50Hz. Technical Specification Flygt 3085, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...7 Product description...7 Motor rating

More information

Submersible Pumps TVS

Submersible Pumps TVS Submersible Pumps TVS in stainless steel Technical Data Performance Range: m Capacity up to 520m 3 /h (2300USgpm) m Head up to 500m (1600feet) m Speed 2900/3500rpm m Motor power up to 400kW (540HP) Pump

More information

Circulating pumps Catalogue

Circulating pumps Catalogue Circulating pumps Catalogue Premier supplier of water equipment Pentair is a diversified operating company headquartered in Minnesota. Its Water Group is a global leader in providing innovative products

More information

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm]

1.0 2.0 3.0 4.0 5.0 6.0 7.0. Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX. 4 8 12 16 20 24 28 Q [US gpm] Product review: Range: Wilo-Star....... Star F Star Star Star F Star Star FX [m /h] Wilo-Star Cast iron body Hz [US gpm].......... [m /h] Wilo-Star Bronze body 9 Hz [US gpm] Star Star Star Star Star BF

More information

Sulzer Pumps Striving to Serve You Better. A Reputation for Excellence

Sulzer Pumps Striving to Serve You Better. A Reputation for Excellence ZPP Double Suction Pumps Sulzer Pumps Striving to Serve You Better Sulzer Pumps is a leading global supplier of reliable products and innovative pumping solutions for end users. Our active research and

More information

Thermal Oil and Hot Water Centrifugal Pumps

Thermal Oil and Hot Water Centrifugal Pumps Thermal Oil and Hot Water Centrifugal Pumps ALLHEAT ALLHEAT Series Centrifugal Pumps Your pumping requirements demand safe, reliable transfer of high temperature materials including heat transfer fluids

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

Selecting a Vertical Turbine Pump (Information required from client)

Selecting a Vertical Turbine Pump (Information required from client) Selecting a Vertical Turbine Pump (Information required from client) 1. Liquid to be pumped: (Note: If liquid is not clear water, the following must also be ascertained). a. Foreign material present in

More information

33LS, 40LS, 55LS, 60LS, 75LS & 80LS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS

33LS, 40LS, 55LS, 60LS, 75LS & 80LS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS TECHNICAL BROCHURE B33-8LS R1 FEATURES Powered for Continuous Operation: All ratings are within the working limits of the motor as recommended by the motor manufacturer. can be operated continuously without

More information

PMS Centrifugal pumps

PMS Centrifugal pumps 1 6033 EN Centrifugal pumps Technical data Delivery rate Q max = 400 l/min Delivery head H max = 45 m Delivery temperature T = 0 C bis +0 C Kinematic viscosity ν max = 20 mm 2 /s Quality Management DIN

More information

PS1800 Centrifugal Pumping Systems

PS1800 Centrifugal Pumping Systems PS1 Centrifugal Pumping Systems General Data and Sizing Tables The curve show the performance range of 4 models at 1Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 3 C

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

Gasketed heat exchanger, XG 65 / 85

Gasketed heat exchanger, XG 65 / 85 Description / application The XG is a heat exchanger with gasket developed for use with district heating and cooling systems. The heat exchangers can be opened for cleaning puposes and for replacement

More information

MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. Water supply. Sprinkler irrigation. Pressure boosting. Fire-fighting.

MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. Water supply. Sprinkler irrigation. Pressure boosting. Fire-fighting. 4 Submersible Pumps GS Series MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. APPLICATIONS Water supply. Sprinkler irrigation. Pressure boosting. Fire-fighting. Compact Sturdy Abrasion resistant All components

More information

STAG. Balancing valves DN , PN 25, with grooved end

STAG. Balancing valves DN , PN 25, with grooved end STAG Balancing valves DN 65-300, PN 25, with grooved end IMI TA / Balancing valves / STAG STAG A grooved end, ductile iron balancing valve that delivers accurate hydronic performance in an impressive range

More information

1 General description

1 General description Specification SERIES: SyScroll 20-30 Air EVO HP TYPE: Air to water inverter driven heat pump TECHNOLOGY: scroll compressor / inverter driven CAPACITY RANGE: Cool ing 20-35 [kw] Heating 20-34 [kw] 1 1 General

More information

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409 Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

Vertical selfpriming Side-Channel Pumps Type WPV

Vertical selfpriming Side-Channel Pumps Type WPV Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling

More information

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

2-way control valves VEFS 2

2-way control valves VEFS 2 Data sheet 2-way control valves VEFS 2 Description/Application VEFS 2 valves are a range of 2 port high specification flanged valves for chilled water, LPHW, MPHW, HPHW (low, medium or high pressure hot

More information

DOMO GRI Submersible Grinder Pump. Lowara

DOMO GRI Submersible Grinder Pump. Lowara DOMO GRI Submersible Grinder Pump Lowara LOWARA LAUNCHES NEW SUBMERSIBLE GRINDER PUMP FOR RESIDENTIAL APPLICATIONS An efficient new grinder pump from Lowara is set to clean up in the domestic sewage market.

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8026 can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor output(s)

More information

pumping liquids JET PUMP TECHNICAL DATA

pumping liquids JET PUMP TECHNICAL DATA Section 000 Bulletin 00 Issued 5/87 Replaces /8 JET PUMP TECHNICAL DATA pumping liquids This technical bulletin includes general information about Penberthy Jet Pumps plus specific details for selecting

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition.

Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition. Oil & Gas CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition. 2 Introduction CHTR Reliable delivery at high pressure. Day in and day out, KSB pumps prove their worth again

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

MULTISTAGE CENTRIFUGAL PUMPS

MULTISTAGE CENTRIFUGAL PUMPS MULTISTAGE CENTRIFUGAL PUMPS MULTISTAGE CENTRIFUGAL PUMPS TK - TKR - VTK - TKK series TK-VTK-TKR-TKK are high pressure multistage pumps. Connection to the driving machine (generally an electrical motor)

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

TECHNICAL CATALOGUE ZONE BALL VALVES WITH UNIDIRECTIONAL ACTUATORS

TECHNICAL CATALOGUE ZONE BALL VALVES WITH UNIDIRECTIONAL ACTUATORS TECHNICAL CATALOGUE ZONE BALL VALVES WITH UNIDIRECTIONAL ACTUATORS TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings

More information

ABB Motors. Aluminium motors

ABB Motors. Aluminium motors Aluminium motors Aluminium motors This product catalogue contains electrical and mechanical data on the aluminium motor range available from. It can be used in conjunction with the catalogue BA/Basic GB

More information

Thrustream Split Case Pumps

Thrustream Split Case Pumps Thrustream Split Case Pumps Thrustream is specially designed for industrial/general purpose users and is one of a comprehensive range of split case products available from SPP. Each range is designed to

More information

Pump-Transfer Cooler Filtration Unit UKF

Pump-Transfer Cooler Filtration Unit UKF Pump-Transfer Cooler Filtration Unit UKF Symbol General The UKF unit is a compact, easy-to-install system for offline filtration cooling circuits. It consists of a low-noise feed pump, a filter and a plate

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering

More information