TCAEY-THAEY

Size: px
Start display at page:

Download "TCAEY-THAEY 5350 6450"

Transcription

1 K20305EN ed.1 TCAEY-THAEY Y-Power range Macrosystem 331,4 455,1 kw 353,4 486,2 kw Air-cooled water chillers and heat pumps with axial fans. Range with hermetic Scroll type compressors and R410A ecological refrigerant.

2 Y-POWER range A comp lete, flexible ser ies Four chiller and heat pump models wit h a cooling capacit y from 331 t o 455 kw and heating capacit y from 535 t o 486 kw. Making it possibl e to choos e the right model on t he basis of t he cooling capacit y required by the us ers, minimsi ng was te. The wat er chillers in the Y-POWER series are also suitabl e for all types of installation, thanks to their ext ensi ve operati ng limits. The st andard unit c an operate from an external air temperature of 45 C down to 5 C (down t o -15 C with the FI15 acc essor y). It can also operate up to temperatur es of 50 C wit h a stepped cooling capacity. ESEER and IP V On average, during their life ti me water chillers suppl y a c ooling capacit y below that for which t hey were acquired. T o ass ess t he average efficienc y, we use the ESEER (European) and IPV (American) indexes. The water chillers in the Y-POWER range have been designed for exc ellent ef ficienc y at partial loads, obtaini ng high ESEER and IPV values, with a c ons equent reduction in energy consumpti on. Control logic The new control logic makes it possible to adapt the water chiller/heat pump operating paramet ers to the load c onditions of the system in which it is installed. The control regulates t he i nlet water t emper ature, opti mising unit operation and the precision of the water s upplied t o t he s ys tem. T he eff ect is boos ted in units t hat us e t he TANK&PUMP option, with a precision guarant ee even in process applications where more precise water t emper ature control is required. Optimised components for R410a The components us ed i n t he Y-POWER series have been s pecificall y devel oped t o achieve high perfor mances and reliability with R 410a gas. The new scroll compress ors and heat exc hangers installed against t he current of plates dedicat ed to this gas, are s ome of t he key elements i n this s eries. T he f an secti on has been sized t o enable opti mum heat exchange and reduced noise. Furthermore, the electronic expansion val ve enables precise, s peedy and punct ual regul ation in the various l oad conditions. Versions Different versions are available t o meet t he specific installation silence requirements The reduced noise of the soundproofed version, with its compr essor compartment with acoustic ins ulation, c an be further implemented t hanks to the reducti on in the fan s peed i n the silent version. Correct operation and performanc es are guarant eed thanks to the optimis ed design of t he f an section. In t he silent version, the electronics enable the chiller to wor k at external air temperat ures of up t o 50 C with stepped cooling capacit y and an increas e in noise when the t emperature exceeds 42 C. A seri es p acked with accessori es The water chillers in the Y-POWER series can be fit ted with t ot al or partial rec over y heat exchangers, as well as traditional accessories, for t he production of hot water up t o 70 C. Fan speed regulati on devic es are available in applications with an ext ernal air temperature down to -15 C. On request, the water chillers can be fitted with a pump assembl y wit h single or double mot or-driven pump, or with a pump assembl y with a 1100-litre wat er buffer t ank and single or double motor-driven pump. 2

3 Y-POWER range Condensing section The design of the condensi ng section and the dynamic flui d flow generat ed by the fans have been pl anned to maximise heat exchange efficienc y and balance the press ure drops, keepi ng the nois e emitt ed i nto the environment as low as possi ble. Moreover, t he standard machi ne i ncludes condens ation control with step press ure s witch, meaning t hat it can be us ed up to an ext ernal air temperature of +5 C. Evaporator Plate evaporator with heat exchange against the c urrent. The evaporat or is equipped wit h t wo cooling circuits, which improves its efficienc y at partial loads. Hydronic assembly Single or double mot or-driven pump, including one in standby with automatic acti vation and standard or increas ed static press ure. Moreover, t he TANK&PUMP version has a 1100-litre inertial water buff er t ank. EEV: Electronic expansion valve The water chillers are fitted as standard with a latest generati on electronic expansion val ve managed by microproc essor c ontrol. In addition to enabling accur ate r efrigerant gas flows, it also allows for accurate chiller assembl y operation, with an eff ecti ve respons e ti me c ompar ed t o t he traditi onal thermost atic expansion val ve. Compressor The Y-POWER s eries us es hermetic scroll compressors specificall y designed to operat e with R 410a gas. Each circuit has 2-3 s tepped c ompressors, for a total of 5-6 steps overall, t hus enabling t he chiller to wor k in an optimum fashion at partial loads, wit h considerable energy s avings. 3

4 general characteristics Contents General ch aracteristics...4 Intended c onditions of use...4 TCAEY-THAEY mod els...5 Construction features...5 Electrical panel...5 Versions...5 Factor y fitted access ories...5 Accessories s upplied l oose...5 Technical dat a...6 Electronic control...10 Description of keypad and displ ay...10 KTR Remote keyboard...10 TRD Thermostat with display...10 SS / FTT10 serial interface...11 Serial connec tion...11 Supervision...11 Performance...11 Choice of mac hine and use of t he performance tables...11 Performance dat a for TCAEB Y-TCAEIY- TCAESY models...12 Performance dat a for THAEB Y-THAEIY- THAESY models...13 RC100 and DS acc essories: performanc es and pressure drops...15 Energy efficienc y at partial loads - EER, ESEER and IPV i ndex...19 Pressure drops at evaporator...19 TCAEY-THAEY r esidu al st atic pr essur es...20 Operating limits for TCAEY-THAEY models...22 Dimensions and footprints...23 Installation...24 Clearances and positioning...24 Movement...24 Weight distribution on fi xture points...25 TCAEY electrical connections...26 THAEY electrical connections...27 General characteristics Intended conditions of use TCAEBY units are air-cooled pac kaged water chillers with axial fans. TCAEIY-TCAESY units are water chillers which are respectively soundproofed and silent. THAEBY units are packaged evaporation/aircooled reversible heat-pumps on the refrigerant cycle. THAEIY-THAESY units are heat pumps which are r espec tivel y soundproofed and silent. They ar e int ended for use i n conditioning plants where a supply of chilled water (TCAEY) or chilled and hot water (THAEY), is required. Not suitabl e for drinking water. The units are designed for outdoor install ation. The units c omply wit h t he following directi ves: Machiner y directive 98/ 37/ EEC (MD); ow volt age directi ve 2006/95/EC ( VD); Electromagnetic Compatibility Directive 89/ 336/EEC (EMC); Pressure Equipment Directive 97/ 23/ EEC (PED). Guide to reading the cod e "SERIES" code "MODE" code T C A E B Y Wat er Scroll-type Approxi mat e produc tion Cooling onl y Air-cooled Standard R410A No. hermetic cooling capacity unit compressors versio n refrigerant fluid compressors (in kw) H I Heat pump Soundproof ed versio n S Silent version Exampl e: TCAEBY 6370 Standard unit, chiller; Air-cooled; 6 x hermetic scroll compressors; R410A refrigerant; Nominal cooling c apacit y of approxi mat ely 370 kw. 4

5 TCAEY-THAEY models Construction features oad-bearing structure in gal vanised and paint ed s heet st eel wit h pol yest er powder coating. Hermetic rotar y scroll compressor, specifically developed to operate with R410a refrigerant gas, complete with internal thermal protecti on and casi ng heater acti vat ed aut omaticall y when t he unit stops (as l ong as the unit is kept connected t o t he power s upply). Stepped cooling capacity of the chiller as in the following table: MODE Compressors/Steps No. Circuits No / /6 2 Wat er side plat e heat exc hanger installed against t he c urrent and made from stainl ess steel, wit h double refrigerant circuit and si ngle wat er side circuit to improve energy efficienc y at partial loads, a differential pressure switc h on the water side and closed cell pol yurethane foam rubber i nsulati on wit h U.V. A. ray protecti on film. Victaulic wat er connections on t he evaporat or, the heat recover y and the desuperheat er. Air side exchanger comprised of copper pipes mec hanicall y flared int o aluminium fins with " turbulenc e" design in or der t o increase energy ef ficienc y. Motor-driven axial fans with external rotor, equipped with inter nal t her mal pr otecti on and complete with protection grilles. They are grouped into t wo s ections (one per refrigerant circuit), each wit h its own circuit breaker. This configuration enables the independent management of the rows of f ans, thus improving energy efficienc y at partial loads and enabling intelligent defrost cycle management (THAEBY-THAEIY-THAESY). The fans are equipped with press ure-switc h control t o ensure operation wit h out door air temperat ure down t o +5 C. Two refrigerant circuits made of annealed copper tubes welded with silver alloy and steel. Each r efrigerant circuit c omes complete with: cartridge drier filter, c harge connections, high pressure s witc h with manual reset, low pressure s witc h with aut omatic res et, gas and humidit y indicat or, elec tronic expansion val ve (hermetic seal function on the liquid line when unit is st ationar y), coc k on the liquid line, c ycle reverse val ve (for THAEBY-THAEIY-THAESY), liquid receiver (for THAEBY-THAEIY-THAESY), compressor suction gas separator (for THAEBY-THAEIY-THAESY), s afety val ves in high pressure secti ons, s uction line insul ation in closed c ell foamed pol yurethane rubber wit h U.V.A. ray protection film. Refrigerant gas high and low pressure gauge for each refrigerant circuit. Charge of ecological R410a refrigerant fluid. Electrical panel Electrical panel c ompliant with IEC standards, in wat ertight box c omplet e with: electrical wiring for the 400V- 3ph-50Hz power suppl y; transfor mer for auxiliary circuit; auxiliary power supply 230V-1ph-50Hz; control power s upply 24V-1ph-50Hz; compressor pr otecti on phase monitor; power cont actors; remote controls: remote ON/OFF, double set-point (DSP accessory); remote machine controls: compressor operating light, general loc k; general isolator with door int erlock on the power suppl y; automatic protection switch on auxiliary circuit; aut omatic t hermal overload switc hes, with fixed c alibration, to protect each compressor/fan (the version with thermal overload s witches, with variable calibration, to protect each c ompressor is opti onal); Programmable elec tronic boar d with microproc essor, managed by the keypad installed on the mac hine, with pot enti al for remot e c ontrol up to 1,000 metres. This electronic board perfor ms t he f ollowing functi ons: regulation and management of the mac hine outlet wat er temperat ure set points; management of the s afety time delays; the wor k timer for each compressor; the automatic inversion of t he c ompress or operating sequenc e; t he circul ating or user ser vice pump (on the evaporat or side and t he c ondenser side); the electronic antifreez e pr otecti on; the shutt er steps and the f uncti ons and that regulate t he operating mode of t he various parts comprising the mac hine; management of the electronic expansi on valve (EEV) with the possibility to read and display t he s uction t emperature, evapor ation pressure and t he opening st atus of the val ve. viewing on dis play of pr ogrammed operati ng paramet ers, machi ne i nlet and outlet wat er temperatures, condensati on pressur es and any alarms; multilingual management (Italian, English, French, German, Spanis h) of the displ ay. management of alar m hist or y. The f ollowing is memorised for eac h al arm: dat e and time of acti vation; alarm c ode and descripti on; the water inl et/outlet temperat ure values when the alar m int ervened; condens ation press ure values at the time of the alarm; alarm delay time from t he s witc h-on of the connected device; compressor and fan st atus when t he alarm inter vened (if the FI10/FI 15 access ory is present, t he analogue output st atus is displayed); self-diagnosis with continuous monit oring of the unit operating st atus. Advanced functions: prepar ed f or serial c onnection, wit h RS 485 outlet for l ogical dialogue with t he main BMS (MODBUS, RTU, ON), centralised systems and super vision net works. management of time periods and operating parameters with the possibility of daily/weekly operating programs ; chec k-up and monitoring of scheduled maintenanc e st atus ; computer-assisted testi ng of the units. Versions B - Standard version (TCAEBY-THAEBY). I - Soundproofed version with s oundproof ed compressor cover (TCAEIY-THAEIY). S - Silenc ed version wit h soundproofed compressor covers and reduc ed-speed f ans (TCAESY-THAESY). general characteristics Factory fitted accessories PUMP - Single or double motor-driven pump, including one i n stand- by, ac tivat ed aut omaticall y on a time basis (for an equal share of oper ating hours) or in the event of an alarm. T he motor-driven pumps are available with s tandar d static press ure (low st atic pressure) and increas ed s tatic pressur e (high static press ure). TANK&PUMP - In additi on to t hat supplied with the PUMP acc essor y, t he pump ass embl y also includes : 1100 l inerti al wat er buffer t ank, expansion tank, bleed and saf et y valves, water drain t ap, electric heater connection and water pressure gauge. The inertial water buffer tank is installed on the wat er circuit deliver y pipe. RAS - Wat er buffer t ank antifreez e el ectric heater t o prevent the risk of ice f ormation inside the heat exchanger when t he machine is switched off ( as long as the unit is not disconnect ed from the power suppl y). RA - Evaporator el ectrical anti-freez e heat er with acti vator. DS - Desuperheater with partial condensation heat recovery. RC100 - Heat rec over y with r ecover y of 100% of t he c ondens ation heat. The accessor y is complete wit h c ondens ation control FI 10 and a differential pressure s witc h on t he r ecover y heat exchanger. TRD - Thermost at with displ ay of the inlet wat er temperature at t he heat r ecover y/ des uperheater with possibility to set the activation set-point of an external control device. RDR - Desuperheat er/recovery antifreez e electric heat er (with DS or RC100 onl y), t o prevent t he ris k of ice f ormation in the recovery heat exchanger when the machine is switched off (as l ong as the unit is kept c onnect ed to the power suppl y). IM - Unit wit h t hermal overload switc hes to protect compress ors. FI10 - El ectronic proportional device for continuous control of rot ation speed of f ans down to an out door air t emperat ure of -10 C. FI15 - El ectronic proportional device for continuous control of rot ation speed of f ans down to an out door air t emperat ure of -15 C. CR - Power fact or correction c apacit ors (cosφ > 0.94). SPS - bott om and top refrigerant pressur e signal, in card. SS - RS 485 serial int erfac e f or logical dialogue with buildi ng aut omation, c entr alised s yst ems and super vision net works ( owner protoc ol, Modbus RTU). FTT10 - ON s erial int erface for c onnection t o BMS with FTT10 standard ON protocol. CMT - power supply MIN/MAX value control. RAP - Unit wit h pre- paint ed aluminium-copper condensing c oils. BRR - Unit with c opper-copper c ondensi ng coils. RPE -ower compartment protective grilles. The f ollowi ng fact ory fitted access ories are availabl e on reques t: DSP - doubl e set- point via digital cons ens us. CS - scrolling set-point (via analogue signal 4-20 ma). Accessories supplied loose KRP - Coil protection grille. KSAM - Spring anti- vibration mountings. KTR - Remote keyboard for remote control, with the same functions as the one built i nto the unit. 5

6 technical data Technical data Table A : Technical data TCAEBY-TCAEIY model STANDARD VERSION - SOUNDPROOFED Nominal cooling c apacit y (*) kw 345,1 365,3 410,2 455,1 E.E.R. (*) 2,85 2,81 2,68 2,60 E.S.E.E.R. 3,85 3,82 3,59 3,51 I.P..V. 4,00 3,97 3,73 3,65 Sound pressure TCAEBY (*) (**) db(a) Sound power l evel TCAEBY (*)(***) db(a) Sound power l evel TCAEIY (*) (***) db(a) Scroll/step compress or No. 5/5 6/6 6/6 6/6 Circuits No Fans No. x kw 8 x 2 8 x 2 8 x 2 8 x 2 Fan nominal air flow m 3 /h Evaporator Type Plates Plates Plates Plates Evaporator nominal water flow (*) m 3 /h 59, 2 62, 7 70, 4 78, 1 Evaporator nominal press ure dr ops (*) kpa Evaporator water c ont ent l R410A refrigerant c harge See s erial no. plate Pol yest er oil charge See s erial no. plate Electri cal data Absorbed power (*) kw 121,0 130,2 153,2 175,0 Electrical power suppl y V-ph-Hz Auxiliary power supply V-ph-Hz Control power suppl y V-ph-Hz Nominal current A Max. current A Starting current A Dimensions Width () mm Height (H) mm Depth (P) mm Hydraulic pumping group Available head press ure, s tandard version (*) ( ) kp a Available head press ure, high head version (*) ( ) kpa Storage t ank capacit y ( ) l (*) In the f ollowi ng conditions : condenser air inlet t emperat ure 35 C; chilled water temperature 7 C; t emper ature diff erenti al at the evaporat or 5 K; incrust ation f actor equivalent t o 0.35x10-4 m 2 K/W (**) Sound pressure l evel db(a) at a distance of 1 metre from the unit (average val ue measured on f our sides) in a free field wit h directionalit y factor Q= 2. (***) Sound power level in db(a) on t he basis of meas urements made in compliance wit h standard UNI EN-ISO 3744 and Eurovent 8/1. ( ) With TANK & PUMP or PUMP acc essor y N.B.: The us ef ul static pressur e values of t he motordriven pumps c an be s een in the graphs on page 20 and the heat exc hanger pressur e drops c an be obtained by f ollowing the instructions on page 19. For the units with integrated pump assembl y, to the electrical absor ption indic ated in the table add the el ectrical absorpti on rel ati ve to t he chosen mot or-driven pumps i ndicated on page 26. The calc ulation of t he E.E.R. does not include mot or-driven pump c ons umption. H P ( ) With TANK & PUMP acc essor y 6

7 technical data Table B : Technical data TCAESY model SIENT VERSION Nominal cooling c apacit y (*) kw 338,2 354,3 397,9 446,0 E.E.R. (*) 2,80 2,73 2,58 2,50 E.S.E.E.R. 3,81 3,66 3,46 3,33 I.P..V. 3,97 3,81 3,59 3,46 Sound pressure TCAESY (*) (**) db(a) Sound power l evel TCAESY (*) (***) db(a) Scroll/step compressor No. 5/5 6/6 6/6 6/6 Circuits No Fans No. x kw 8 x x x x 1.2 Fan nominal air flow m 3 /h Evaporator Type Plates Plates Plates Plates Evaporator nominal water flow (*) m 3 /h 58, 0 60, 8 68, 3 76, 5 Evaporator nominal press ure dr ops (*) kp a Evaporator water c ont ent l R410A refrigerant c harge See s erial No. plat e Pol yest er oil charge See s erial no. plate Electri cal data Absorbed power (*) kw 120,6 129,8 154,3 178,1 Electrical power suppl y V-ph-Hz Auxiliary power supply V-ph-Hz Control power suppl y V-ph-Hz Nominal current A Max. current A 273,8 301,8 331,8 361,8 Starting current A 528,8 513,8 586,8 616,8 Dimensions Width () mm Height (H) mm Depth (P) mm Hydraulic pumping group Available head press ure, s tandard version (*) ( ) kpa Available head press ure, high head version (*) ( ) kp a Storage t ank capacit y ( ) l (*) In the f ollowi ng conditions : condenser air inlet t emperat ure 35 C; chilled water temperature 7 C; t emper ature diff erenti al at the evaporat or 5 K; incrust ation f actor equivalent t o 0.35x10-4 m 2 K/W (**) Sound pressure l evel db(a) at a distance of 1 metre from the unit (average val ue measured on f our sides) in a free field wit h directionalit y factor Q= 2. (***) Sound power level in db(a) on t he basis of meas urements made in compliance wit h standard UNI EN-ISO 3744 and Eurovent 8/1. ( ) With TANK & PUMP or PUMP acc essor y N.B.: The us ef ul static pressur e values of t he motordriven pumps c an be s een in the graphs on page 20 and the heat exc hanger pressur e drops c an be obtained by f ollowing the instructions on page 19. For the units with integrated pump assembl y, to the electrical absor ption indic ated in the table add the el ectrical absorpti on rel ati ve to t he chosen mot or-driven pumps i ndicated on page 26. The calc ulation of t he E.E.R. does not include mot or-driven pump c ons umption. H P ( ) With TANK & PUMP acc essor y 7

8 technical data Table C : Technical data THAEBY-THAEIY model STANDARD VERSION - SOUNDPROOFED Nominal cooling c apacit y (*) kw 338,2 357,8 402,0 446,1 E.E.R. (*) 2,77 2,72 2,61 2,52 E.S.E.E.R. 3,74 3,70 3,53 3,43 I.P..V. 3,88 3,85 3,67 3,57 Nominal heating capacity (**) 372,0 393,6 434,2 486,2 C.O.P. (**) 2,95 2,92 2,89 2,85 Sound pressure (*)(***) db(a) Sound power l evel THAEBY (*) (****) db(a) Sound power l evel THAEIY (*) (****) db(a) Scroll/step compress or No. 5/5 6/6 6/6 6/6 Circuits No Fans No. x kw 8 x 2 8 x 2 8 x 2 8 x 2 Fan nominal air flow m 3 /h Evaporator/c ondenser Type Plates Plates Plates Plates Evaporator/c ondenser nominal water flow (**) m 3 /h 64, 8 68, 6 75, 6 84, 7 Evaporator/c ondenser nominal pressure drops (**) kpa Evaporator water c ont ent l R410A refrigerant c harge See s erial No. plat e Pol yest er oil charge See s erial no. plate Electri cal data Absorbed power in wint er operation (**) kw ,7 150,2 170,9 Absorbed power in summer oper ation (*) kw 122,2 131,5 153,8 176,7 Electrical power suppl y V-ph-Hz Auxiliary power supply V-ph-Hz Control power suppl y V-ph-Hz Nominal current A Max. current A Starting current A Dimensions Width () mm Height (H) mm Depth (P) mm Hydraulic pumping group Available head press ure, s tandard version (**) ( ) kpa Available head press ure, high head version (**) ( ) kpa Storage t ank capacit y ( ) l (*) In the f ollowi ng conditions : condenser air inlet t emperat ure 35 C; chilled water temperature 7 C; t emper ature diff erenti al at the evaporat or 5 K; incrust ation f actor equivalent t o 0.35x10-4 m 2 K/W (**) In the f ollowi ng conditions : evaporator i nlet air temperature 7 C D.B., 6 C W.B.; hot wat er temperature 45 C; temperat ure dif ferential at the condenser 5 C. (***) Sound pressure level db(a) at a distance of 1 metre fr om the unit (aver age value measured on f our sides) in a free field wit h directionality fac tor Q=2. ( ) With TANK & PUMP or PUMP acc essor y ( ) With TANK & PUMP acc essor y N.B.: The us ef ul static pressur e values of t he motordriven pumps c an be s een in the graphs on page 20 and the heat exc hanger pressur e drops c an be obtained by f ollowing the instructions on page 19. For the units with integrated pump assembl y, to the electrical absor ption indic ated in the table add the el ectrical absorpti on rel ati ve to t he chosen mot or-driven pumps i ndicated on page 27. H P (****) Sound power l evel in db(a) on the basis of meas urements made in compliance wit h standard UNI EN-ISO 3744 and Eurovent 8/1. The calc ulation of t he E.E.R. and C.O.P. does not take the mot or-driven pump abs orption int o account. 8

9 technical data Table D : Technical data THAESY model SIENT VERSION Nominal cooling c apacit y (*) kw 331,4 350,6 394,0 437,2 E.E.R. (*) 2,70 2,66 2,52 2,45 E.S.E.E.R. 3,62 3,59 3,43 3,26 I.P..V. 3,77 3,73 3,57 3,39 Nominal heating capacity (**) 353,4 373,9 412,5 461,9 C.O.P. (**) 2,92 2,89 2,86 2,82 Sound pressure (*)(***) db(a) Sound power l evel (*) (****) db(a) Scroll/step compressor No. 5/5 6/6 6/6 6/6 Circuits No Fans No. x kw 8 x x x x 1.2 Fan nominal air flow m 3 /h Evaporator/c ondenser Type Plates Plates Plates Plates Evaporator/c ondenser nominal water flow (**) m 3 /h 61, 6 65, 1 71, 9 80, 5 Evaporator/c ondenser nominal pressure drops (**) kp a Evaporator water c ont ent l R410A refrigerant c harge See s erial No. plat e Pol yest er oil charge See s erial No. plat e Electri cal data Absorbed power in wint er operation (**) kw 120,6 128,9 143,8 163,7 Absorbed power in summer oper ation (*) kw 122,6 132,0 156,1 178,6 Electrical power suppl y V-ph-Hz Auxiliary power supply V-ph-Hz Control power suppl y V-ph-Hz Nominal current A Max. current A 273,8 301,8 331,8 361,8 Starting current A 528,8 513,8 586,8 616,8 Dimensions Width () mm Height (H) mm Depth (P) mm Hydraulic pumping group Available head press ure, s tandard version (**) ( ) kp a Available head press ure, high head version (**) ( ) kp a Storage t ank capacit y ( ) l (*) In the f ollowi ng conditions : condenser air inlet t emperat ure 35 C; chilled water temperature 7 C; t emper ature diff erenti al at the evaporat or 5 K; incrust ation f actor equivalent t o 0.35x10-4 m 2 K/W (**) In the f ollowi ng conditions : evaporator i nlet air temperature 7 C D.B., 6 C W.B.; hot wat er temperature 45 C; temperat ure dif ferential at the condenser 5 C. ( ) With TANK & PUMP or PUMP acc essor y ( ) With TANK & PUMP acc essor y N.B.: The us ef ul static pressur e values of t he motordriven pumps c an be s een in the graphs on page 20 and the heat exc hanger pressur e drops c an be obtained by f ollowing the instructions on page 19. H (**) Sound pressure l evel db(a) at a distance of 1 metre from the unit (average val ue measured on f our sides) in a free field wit h directionalit y factor Q= 2. (****) Sound power l evel in db(a) on the basis of meas urements made in compliance wit h standard UNI EN-ISO 3744 and Eurovent 8/1. For the units with integrated pump assembl y, to the electrical absor ption indic ated in the table add the el ectrical absorpti on rel ati ve to t he chosen mot or-driven pumps i ndicated on page 27. The calc ulation of t he E.E.R. and C.O.P. does not take the mot or-driven pump abs orption int o account. P 9

10 electronic control Electronic control Description of keypad and display The keyboard with display makes it possible to view the wor king temperature and all t he unit proc ess variables, as well as providi ng access t o setting paramet ers for oper ating set poi nts and their modification. For purposes of technical assistance, it allows passwordprotect ed access to the unit's management par ameters (acc ess f or aut horised pers onnel onl y). KTR Remote keyboard The remot e keyboard with displ ay (KTR) allows t he remote c ontr ol and display of all t he unit's digital and anal ogue process variables. It theref ore possibl e to control all t he machine f uncti ons directl y in t he room. Makes it possible t o s et and manage the ti me bands. Note: The t emporar y presence of t wo devices, on- boar d machi ne keyboard and remote keyboar d, will cause the on-board machine terminal to be disabled.! AARM TRD Thermostat with display SE 2 Prg MODE PRG mute 3 ON OFF 4 5! AARM Prg ON OFF MODE DISPAY: displays t he numbers and the values of all the parameters (i.e. outlet water t emper ature etc.), any alarm c odes and r esource st atus by means of strings. AARM key: makes it possible to display of the code and reset any alarms. PRG key: makes it possible to programme the mac hine's operating par ameters. ON/OFF key: makes it possible to s witc h t he unit on and off. UP key: used to scr oll through the list of paramet ers, status es and any alar ms; makes it possibl e to modif y set poi nts. MODE - ENTER key: makes it possible to switch from chiller to heat pump operation and vice versa. DOWN key: used to scr oll through the list of paramet ers, status es and any alar ms; makes it possibl e to modif y set poi nts. 1 The inst allation of t he t her most at wit h displ ay (TRD) accessor y in the mac hine makes it possi ble t o dis play t he r ecover y/ des uperheater inl et wat er temperat ure and to set the ac tivation set-point of an ext ernal regulation device (i.e. ON/ OFF 3- way valve), enabling rational and effec tive us e of t he rec over ed t her mal energ y. 1 = DISP AY: displays t he r ecover y/ des uperheater inl et water t emperat ure. 2/4/ 5 = SE, (up), (down) keys: make it possible to s et the set- point and acti vati on differential of an external regulation device. 3 = PRG/mute key: makes it possible to access the parameter programming menu. 10

11 ! AARM Prg ON OFF MODE TCAEY-THAEY serial connection/performances SS / FTT10 serial interface Serial connection All units are equi pped with elec tronic c ontrol that can int erfac e with an ext ernal s yst em via a serial c ommunicati on line by means of t he KIS s erial int erface acc essor y (proprietar y pr otoc ol or ModBus RTU) and t he KCH converter. Supervision In general, a supervision system allows access to all unit functi ons, s uch as: making all s ettings which are accessi ble t hrough the ke yboard; reading all process variables of the inputs and out puts, whether digital or anal ogue; reading t he various alarm c odes whic h are pres ent, and resetting t hem as nec essar y; reading all programming par ameters and var ying some of them. Note: for further information contact the R hoss s ales s upport service. Performance Choice of machine and use of the performance tables Tables E and F for the TCAEY models and tables G and H for the THAEY models provide the cooling capacit y (QF) and abs orbed electrical power (P) on the basis of t he evaporat or outlet water t emperature wit h const ant temperatur e diff erentials Δt = 5 C and the exter nal air t emperature. Tables I and J for THAEY models provide the heating capacit y (QT) and the absorbed electrical power (P), on t he basis of t he condens er outlet water t emper ature wit h const ant temperatur e diff erentials Δt = 5 C and the exter nal air t emperature and relative humidit y. In keeping with the operating limits (see page 22) tables E, F, G, H, I and J can enable perfor mance i nterpolati ons, but extrapolations ar e not permit ted. Tables P, Q, R, and " S provide t he E.E.R, ESEER and IPV energy index val ues for eac h model. Tables U and V pr ovide the sound pressure values in db by oct ave bands, t he total s ound power l evel in db(a) and the s ound pressure values in db(a) at diff erent dist anc es for eac h model. Table W shows the values of corrective coefficients t o be applied to t he nominal values if water with gl ycol is used. Charts 1, 2, 3 and 4 indic ate the residual st atic pressure of the pump (if pres ent). 11

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual

High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual High efficiency air/water reversible heat pumps type Geyser Mini Technical information manual 2 GEYSER MINI Reversible heat pump Index Technical features 120 Basic version general technical data 124 Basic

More information

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48

Kälte Klima. Condenserless chillers for indoor installation from 45 kw to 360 kw. Scroll compressors SCLY DE 48 Condenserless chillers for indoor installation from 45 kw to 360 kw Scroll compressors Series: SCLY Leaflet: DE 48 Issue: 03/12 Supersedes: 04/11 Index Identification code Index... pag. 2 Identification

More information

1 General description

1 General description Specification SERIES: SyScroll 20-30 Air EVO HP TYPE: Air to water inverter driven heat pump TECHNOLOGY: scroll compressor / inverter driven CAPACITY RANGE: Cool ing 20-35 [kw] Heating 20-34 [kw] 1 1 General

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI

Refrigerant R410A. Mini SysAqua DCI. 5.5 to 16.0kW. Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI Refrigerant R4A Mini SysAqua DCI Air-to-Water DCI Heat Pumps Models M.AQA05 DCI to M.AQA16 DCI 5.5 to 16.0kW Mini SysAqua DCI 1 Strength Points By introducing the variable speed in our packaged heat pump

More information

Water Chillers - The range CH and RPW series

Water Chillers - The range CH and RPW series Water Chillers - The range CH and RPW series PIOVAN S.p.A. Cooling Centre 1 (1) Piovan Chiller Range Piovan Spa 03.2004 Modification reserved Water chillers A dedicated Cooling Centre Integration with

More information

ALARM. Alarm Alarm description Reset AL: 002 Antifreeze lockout alar m

ALARM. Alarm Alarm description Reset AL: 002 Antifreeze lockout alar m SECTION I: USER I.6.8 LRM SIGNLS IMPORTNT! Malfunctions and alarms displayed b y the machine should NEVER b e ignored. The problem should b e checked and resolved as soon as po ssible. If the alarm re-occurs,

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

AIR COOLED CONDENSING UNITS SERIE UMC/E. Cooling and heating split systems for comfort and process application

AIR COOLED CONDENSING UNITS SERIE UMC/E. Cooling and heating split systems for comfort and process application AIR COOLED CONDENSING UNITS SERIE UMC/E Cooling and heating split systems for comfort and process application 50-400 KW UMC/E AIR COOLED CONDENSING UNITS Range overview UMC/E = cooling only UMC/E-HP =

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

High Static Pressure Ductable Fan Coil Unit Models 07 to 27

High Static Pressure Ductable Fan Coil Unit Models 07 to 27 VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 5.3 to 26.9kW 4.1 to 22.6kW 800 to 4650 m 3 /h VH 1 General Characteristics Presentation The new ducted high static pressure fan coil units

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER MULTIPURPOSE HEAT PUMPS AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER Multipurpose air cooled units with axial fans. For external installation. High efficiency version. MULTIPURPOSE NRP The

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

DX Condensing Units for both cooling and heat pump applications

DX Condensing Units for both cooling and heat pump applications DX for both cooling and heat pump applications 3 VES Andover offer a comprehensive range of condensing units for both cooling only and heat pump application, designed to match your VES air handling unit.

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

Packaged Air Conditioner - Water Cooled Vertical Type Model 25

Packaged Air Conditioner - Water Cooled Vertical Type Model 25 Refrigerant R407C CX Packaged Air Conditioner - Water Cooled Vertical Type Model 25 8.0kW CX 25 1 Product Code Model Power supply Product code CX 25 230V / 1 ~ / 50 Hz 7XU012153 CX 25 CX 25 2 CX 25 General

More information

Air/water chillers. With plug fans and scroll compressors, for indoor installation Model CGCM Cooling capacity kw CGCM-PRC001A-GB

Air/water chillers. With plug fans and scroll compressors, for indoor installation Model CGCM Cooling capacity kw CGCM-PRC001A-GB Air/water chillers With plug fans and scroll compressors, for indoor installation Model CGCM Cooling capacity 44-315 kw CGCM-PRC001A-GB Contents Technical specifications...4 Options and accessories...9

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None

Low and High Static Pressure Fan Coil Units. VH2N 03 to 27. Technical Brochure. TM VH2N-A.1GB Date : June 2006 Supersedes : None Low and High Static Pressure Fan Coil Units VH2N 03 to 27 Technical Brochure TM VH2N-A.1GB Date : June 2006 Supersedes : None Design Features Presentation The VH2N fan coil units has been specially designed

More information

SMM. Installation Operation Maintenance

SMM. Installation Operation Maintenance SMM Configuration SMM Module for Scroll Units, H Generation Installation Operation Maintenance 1 0 L80 IM 022 GB SMM Configuration SMM Module for Scroll Units, H generation Foreword These installation,

More information

Chillers, heat pumps and domestic hot water production units from 18 to 45 kw capacity with R-410A

Chillers, heat pumps and domestic hot water production units from 18 to 45 kw capacity with R-410A Chillers, heat pumps and domestic hot water production units from 8 to 45 capacity with R40A Maximum efficiency Absolute modularity Innovative technology For over 90% of its operating time, a system's

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

INSTALLATION OPERATING & MAINTENANCE MANUAL

INSTALLATION OPERATING & MAINTENANCE MANUAL INSTALLATION OPERATING & MAINTENANCE MANUAL Basic Climatic TM Controller Ecologic English November 2002 CONTENTS PAGE GENERAL DESCRIPTION 3 USER INTERFACE 4 The keypad incorporated on the unit 4 The keypad

More information

MCA MCA (R-407C) SPLIT SYSTEM

MCA MCA (R-407C) SPLIT SYSTEM 21-1 MCA 21-1 AIR COOLED CONDENSING UNIT (COOLING ONLY) FOR INDOOR INSTALLATION MCA 21-1 (R-40C) Size Cooling [kw] 21.4 2.91 1.4 41.0 1 14.1 1 20. 91 2. 101 1.9 1. These units are used in split type installation

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections High efficiency HYRID heat pumps with E.V.I compressor in two sections infolinia: +48 691 262 691-20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency hybrid heat pumps has been specifically designed

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

Aqualean Horizontal Water Cooled Packaged Air Conditioner

Aqualean Horizontal Water Cooled Packaged Air Conditioner Aqualean Horizontal Water Cooled Packaged Air Conditioner More thermal comfort with less energy consumption Exclusively distributed by Aqualean Introduction & Overview AQUALEAN is a water sourced heat

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

AIR COOLED WATER CHILLERS, CONDENSING UNITS AND HEAT PUMPS WITH AXIAL FANS LDK SERIES TECHNICAL MANUAL

AIR COOLED WATER CHILLERS, CONDENSING UNITS AND HEAT PUMPS WITH AXIAL FANS LDK SERIES TECHNICAL MANUAL AIR COOLED WATER CHILLERS, CONDENSING UNITS AND HEAT PUMPS WITH AXIAL FANS LDK SERIES TECHNICAL MANUAL 2 INDEX Declaration of conformity page 2 Aim and contents of this manual page 6 How to keep this manual

More information

Features and Benefits

Features and Benefits Refrigeration 2 eatures and Benefits Based on IR32 Parameters Real Time lock ( RT ) Model Specific (defrost based on real time 7 day 24 hour) HAP (Hazard Analysis and ritical ontrol Point) Alarm Available

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Zeta Echos air/water chillers and heat pumps Technical information manual

Zeta Echos air/water chillers and heat pumps Technical information manual Zeta Echos air/water chillers and heat pumps Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl ZETA ECHOS Water chiller ZETA ECHOS/HP Reversible heat pump

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

MAROON 2. 6 78 kw. General information. Unique selling points

MAROON 2. 6 78 kw. General information. Unique selling points 6 78 kw General information Dedicated heat pumps new series with Scroll compressors, with and without vapor injection. /HT version in 15 sizes Cooling capacity (35;W7): 6 73 KW Heating capacity (7;W45):

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

PRODUCT CATALOGUE AIR COOLED CONDENSING UNIT RA

PRODUCT CATALOGUE AIR COOLED CONDENSING UNIT RA PRODUT TLOGUE IR OOLED ONDENSING UNIT R English/02-2005 IR OOLED ONDENSING UNIT INTRODUTION TO THE RNGE The R air-cooled units are developed from the EOLOGI liquid chiller range and share the same design

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

YCAA-B AIR COOLED LIQUID CHILLER

YCAA-B AIR COOLED LIQUID CHILLER YCAA-B AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 46 kw to 152 kw York YCAA-B twin refrigerant circuit air cooled liquid chillers are a compact design suitable for chilled water or

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

MSC Scroll Liquid Chillers

MSC Scroll Liquid Chillers MSC Scroll Liquid Chillers n 15 60 Tons n Water-Cooled or Split System n Optional Heat Recovery n Optional Tank & Pumps n Specialized HVAC Systems n Industrial Process Cooling cooling solutions www.motivaircorp.com

More information

CGCL CG-PRC009-E4

CGCL CG-PRC009-E4 Air Cooled Water Chiller With Centrifugal Fans CGCL 200-250 - 300-350 - 400-450 - 500-600 CG-PRC009-E4 Contents Features And Benefits 3 General Data 5 Condenser Fan Performance 6 Pressure drop through

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

Energy Savings as Standard

Energy Savings as Standard Heating Hot water Renewables HEAT PUMP WATER HEATERS NUOS FS FLOOR STANDING UNVENTED CYLINDER WITH INTEGRATED AIR SOURCE HEAT PUMP Eco-friendly home? With the Ariston NUOS now it ca Energy Savings as Standard

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03 Domestic Air Conditioner SERVICE MANUAL Model HW-05LN03 Feature Anti-mold filter Mechanical control Easy clean filters Slide chassis 4-way airflow direction 2 cool settings, 2 fan settings Serial Number:

More information

The Next Generation Concealed Water Cooled Package Unit. Mon Feb

The Next Generation Concealed Water Cooled Package Unit. Mon Feb The Next Generation Concealed Water Cooled Package Unit Mon Feb 24 2014 Mon Feb 24 2014 Introducing the Next Generation Vertical Water Cooled Package Units Ideal for Apartments and Office Buildings Concealed

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Carisma CRSO. All range is compliant with the new ERP 2013 Regulation (EU) High Pressure Fan Coil Unit with Asynchronous Motor

Carisma CRSO. All range is compliant with the new ERP 2013 Regulation (EU) High Pressure Fan Coil Unit with Asynchronous Motor Carisma CRSO igh Pressure Fan Coil Unit with Asynchronous Motor Range includes air rates (from 375 to 2220 m 3 /h) each equipped with 3 or row coil and with the possibility to add a 1 or 2 row coil for

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Nordic Heat Pump Product Guide

Nordic Heat Pump Product Guide Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

Mirage over door heater. Features: Electric and LPHW versions. Compact and Versatile. Suitable for mounting up to 3.0m high from finished floor level.

Mirage over door heater. Features: Electric and LPHW versions. Compact and Versatile. Suitable for mounting up to 3.0m high from finished floor level. Features: Electric and LPHW versions. Compact and Versatile Suitable for mounting up to 3.0m high from finished floor level. Recessed or surface mounted. Energy saving controls option available. Available

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

We have been working in an ideal climate for thirty years.

We have been working in an ideal climate for thirty years. Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS

50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS 50XJ-3SB 50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS PERFORMANCE DATA DIMENSION PRINTS PLENUM DIMENSION PRINT Copyright 2004 Carrier Corporation Syracuse,

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43

D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43 D SERIES MODULAR AIR-COOLED SCROLL CHILLER TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43 CONTENTS 1.MODELS LIST... 3 2.NOMENCLATURE... 3 3.FEATURES... 3 4.PRODUCT

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:

More information

geotherm Ground Source Heat Pumps Vaillant geotherm exclusive Vaillant geotherm

geotherm Ground Source Heat Pumps Vaillant geotherm exclusive Vaillant geotherm geotherm Ground Source Heat Pumps Vaillant geotherm exclusive Vaillant geotherm Introduction Your future energy supply Renewable Energy With global temperatures continuing to rise and as traditional energy

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS Made in Sweden ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for

More information

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as: CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living

More information

Adjustable room thermostat for heating only or cooling only systems

Adjustable room thermostat for heating only or cooling only systems 3 003 Room hermostat RAA30 Adjustable room thermostat for heating only or cooling only systems Room thermostat with manual O/OFF switch wo-position control witching voltage AC 24 250 V Use he RAA30 room

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

AIR SOURCE CHILLERS FOR OUTDOOR INSTALLATION

AIR SOURCE CHILLERS FOR OUTDOOR INSTALLATION AIR SOURCE CHILLERS FOR OUTDOOR INSTALLATION HIGH EFFICIENCY LATEST CONTROL SYSTEM LEED RELEVANT PRODUCT EXTREMELY SILENT OPERATIONS Features High efficiency chiller, air source for outdoor installation

More information

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS WORKING DOCUMENT ON Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS WORKING DOCUMENT in the framework of the implementation of

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: Test Report issued under the responsibility of: TEST REPORT EHPA-DACH Testing Regulation Supplemental requirements for granting the international quality label for heat pumps Testing of Air/Water Heat

More information

ice 3 FLUID TO FLUID HEAT PUMP

ice 3 FLUID TO FLUID HEAT PUMP ice 3 FLUID TO FLUID HEAT PUMP SUBMITTAL DATA (888) 530-7713 P O Box 5, Wentworth, H 03282 Rev.3 (5-30-14) ice 3, IC-2040 Fluid-to-Fluid R-410a Heat Pump Engineering Guide Specifications General otes:

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information