Scanning Electron Microscopy

Size: px
Start display at page:

Download "Scanning Electron Microscopy"

Transcription

1 Scanning Electron Microscopy Instrument Imaging Chemical Analysis (EDX) Structural and Chemical Analysis of Materials J.P. Eberhart John Wiley & Sons, Chichester, England, Scanning Electron Microscopy and X-Ray Microanalysis J. Goldstein, D. Newbury, D. Joy, C. Lyman, P. Echlin, E. Lifshin, L. Sawyer, J. Michael Kluwer Academic/Plenum Publishers, New York, 2003.

2 1. A column which generates a beam of electrons. 2. A specimen chamber where the electron beam interacts with the sample. 3. Detectors to monitor the different signals that result from the electron beam/sample interaction A viewing system that builds an image from the detector signal.

3 Reduced image of crossover Project the crossover image onto the specimen X-Y translation + rotation

4 SEM Image not formed by focusing of lenses X-ray maps can be displayed. Resolution not limited by lens aberrations (in the usual sense of image forming lenses is limited by the objective lens aberrations which determines the minimum probe size). Imaging involves digital processing online image enhancement and offline image processing. Resolution limited by probe size and beam spreading on interaction with specimen. Hence, resolution depends on the signal being used for the formation of the image.

5 A fine electron probe is scanned over the specimen. Various detectors (Secondary Electron (SE), Back Scattered Electron (BSE), X- Ray, Auger Electron (AE) etc.) pick up the signals. The amplified output of a detector controls the intensity of the electron beam of a CRT (synchronized scanning) of the pixel of display Scanning Electron Beam Various Detectors (SE, BSE, EDX, AE) Display on CRT Parameter Resolution Magnification Values ~ 40 Å (SE); ~ ( ) Å (BSE) Note that the resolution depends on the type of signal being used Depth of field High (~ m) Importance of SEM Size of specimen 1 5 cm (usual range)

6 Many signals are generated by the interaction of the electron beam with the specimen. Each of these signals is sensitive to a different aspect of the specimen and give a variety of information about the specimen. Auger Electrons Backscattered Electrons (BSE) Absorbed Electrons Incident High-kV Beam SPECIMEN Secondary Electrons (SE) Characteristic X-rays Bremsstrahlung X- rays Visible Light Electron-Hole Pairs Elastically Scattered Electrons In a SEM these signals are absent Direct Beam Inelastically Scattered Electrons

7 Signals An important point to note is the fact that the different signals are generated essentially* from different regions in the specimen. This determines: as to what the signal is sensitive to the intensity of the signal. Not to scale The X-rays generated by the electrons are the Primary X-rays The primary X-rays can further lead to electronic transitions which give rise to the Secondary X-rays (Fluorescent X-rays) Interaction volume volume which the electrons interact with Sampling volume volume from which a particular signal (e.g. X-rays) originates * Monte Carlo simulations are used to find the trajectory of electrons in the specimen and determine the probability of various processes

8

9 X-ray fluorescence and Auger electrons kev e Electron from beam knocks out a core electron Photoelectrons 2 Transition from higher energy level to fill core level

10 3 Generation of x-rays accompanying the transition 4 Further the x-ray could knock out an electron from an outer level this electron is called the Auger electron

11 Electron-hole pairs and cathodoluminescence Photoluminescence Photon induced light emission e Incident electron excites an electron from the valence band to the conduction band creating an electron hole pair Cathodoluminescence Electron induced light emission Conduction band Band gap e Semiconductors Valence band hole Cathodoluminescence (CL) Spectroscopy h OR Bias Electron beam induced current ( EBIC) Charge collection microscopy

12 Secondary Electrons (SE) Produced by inelastic interactions of high energy electrons with valence electrons of atoms in the specimen which cause the ejection of the electrons from the atoms. After undergoing additional scattering events while traveling through the specimen, some of these ejected electrons emerge from the surface of the specimen. Arbitrarily, such emergent electrons with energies less than 50 ev are called secondary electrons; 90% of secondary electrons have energies less than 10 ev; most, from 2 to 5 ev. Being low in energy they can be bent by the bias from the detector and hence even those secondary electrons which are not in the line of sight of the detector can be captured.

13 Secondary Electrons Some Z contrast! SE are generated by 3 different mechanisms: SE(I) are produced by interactions of electrons from the incident beam with specimen atoms SE(II) are produced by interactions of high energy BSE with specimen atoms SE(III) are produced by high energy BSE which strike pole pieces and other solid objects near the specimen.

14 Back Scattered Electrons (BSE) Produced by elastic interactions of beam electrons with nuclei of atoms in the specimen Energy loss less than 1 ev Scattering angles range up to 180, but average about 5 Many incident electrons undergo a series of such elastic event that cause them to be scattered back out of the specimen The fraction of beam electrons backscattered in this way varies strongly with the atomic number Z of the scattering atoms, but does not change much with changes in E 0. n n BSE IE Dependence on atomic number BSE images show atomic number contrast (features of high average Z appear brighter than those of low average Z)

15 Detectors Note that SE not in traveling in the line of sight can also be captured by the detector Secondary Electrons Backscattered Electrons

16 Magnification The magnification in an SEM is of Geometrical origin (this is unlike a TEM or a optical microscope) Probe scans a small region of the sample, which is projected to a large area (giving rise to the magnification). Area scanned on specimen Area projected onto display

17 Depth of field Dependent on the angle of convergence of the beam Depth of field is the same order of magnitude as the scan length Magnification 10,000 Scan length 10 m Depth of Field 8 m

18 What determines the resolution in an SEM? Probe size (probe size is dependent on many factors) Signal being used for imaging This is because the actual interaction volume/cross section is different from the probe diameter. Additionally, each signal is sensitive to a different aspect of the specimen. In terms of parameters: Accelerating voltage Beam current Beam diameter Convergence angle of beam

19 Topographic Contrast in SEM Inclination Effect Shadowing Contrast Line of sight with the detector Edge/Spike Contrast

20 Operating parameters affecting signal quality Accelerating Voltage Probe Current Working Distance Specimen Tilt Aperture Size Edge effect Contamination Charging

21 Operating Parameter Gun voltage Working distance Values ~20 kev ~26 mm Probe size W filament ~30 Å LaB 6 Field Emission Vacuum W filament 10 5 Torr LaB 6 Field Emission 10 8 Torr Torr Probe current Probe diameter Resolution This leads to decrease in image intensity we have to use a brighter source (W filament < LaB 6 < Field Emission gun)

22 Comparison of Electron Sources at 20kV Work Function Operating Temperature Units Tungsten LaB 6 FEG (cold) FEG (thermal) FEG (Schottky) ev K Current Density Crossover Size A/m 2 5* μ m <0.005 < Brightness A/cm 2 sr Energy Speed ev Stability %/hr <1 <1 5 5 ~1 Vacuum PA Lifetime hr >1000 >1000 >1000

23 Increasing Resolution Probe size Probe Current strength of condenser lens Working Distance Leads to Beam convergence angle spherical aberration Working Distance Specimen Tilt Aperture Size Edge effect Contamination Charging

24 Image Processing Any signal picked up by a detector can be converted to an electrical signal and be used of imaging Contrast processing +ve to ve contrast, gamma control etc. Contrast quantification contour mapping, colour mapping Image integration signal integration over a number of scans ( SNR) Usual image analysis phase fractions etc.

25 Backscattered Electron Images Emission of Backscattered electrons = f(composition, surface topography, crystallinity, magnetism of the specimen) Composition Z number Topography and composition information is separated using detector Crystallinity channeling contrast (& EBSD) (the BSE intensity changes drastically on or around Bragg s condition) Poorer spatial resolution

26 Backscattered Electron Signals Detectors Signal A Signal B A + B A B Composition (COMPO) Topography (TOPO)

27 COMPO: A + B TOPO: A B Specimen: Metallic 20 kv, 1100 Ref: SEM Manual, JEOL

28 Secondary Electron Image (SEI) Backscattered Electron Image (BEI) X-ray image (Si) X-ray image (Al) Specimen: Metallic 20 kv, 1100 Composition via: BEI EDX Ref: SEM Manual, JEOL

29

30 High Resolution Unclear surface structures More edge effect More charge-up More damage Accelerating Voltage Clear surface structures Less damage Less charge-up Less edge effect Low resolution

31 Low atomic number High atomic number Low accelerating voltage High accelerating voltage

32 kv 30 kv Specimen: Toner Accelerating voltage Increased contribution of BSE Low surface contrast Charging Ref: SEM Manual, JEOL

33 kv 25 kv Specimen: Sintered powder Accelerating voltage Better surface contrast Not sharp at high magnifications WD or probe diameter Ref: SEM Manual, JEOL

34 kv 5 kv Specimen: Evaporated Au particles Accelerating voltage Better image sharpness Improved resolution Ref: SEM Manual, JEOL

35 kv 5 kv Specimen: Paint coat Accelerating voltage Low surface contrast More BSE contributions from within the specimen Ref: SEM Manual, JEOL

36 Specimen tilt 5kV, Specimen: IC chip TILT Improve quality of SE images complete survey of topography Stereo images images at 2 angles Ref: SEM Manual, JEOL

37 Smooth image Deteriorated resolution More damage Probe current High-resolution obtainable Grainy image

38 10 kv, na 0.1 na 10 pa Specimen: Ceramic Probe current image sharpness surface smoothness Ref: SEM Manual, JEOL

39 Greater depth of field Low resolution Working Distance working distance spherical aberration (spot size resolution improves) High resolution Low depth of field working distance Depth of field (wide cone of electrons) The working distance is the distance between the final condenser lens and the specimen

40 Large current e.g. Better for EDX Low resolution Smaller depth of field Aperture size (objective lens) High resolution Greater depth of field Grainy image

41 Edge Effect SE emission from protrusions and circumferences appear bright Accelerating voltage Greater the edge effect (edges become brighter) 5 kv 25 kv Tilt: 50, 720 Specimen: IC chip Ref: SEM Manual, JEOL

42 Charging Due to low conductivity of sample Coating with a conducting material to avoid charging To charging Voltage, probe current, tilt specimen 4 kv Specimen: Foreleg of vinegar fly 10 kv Accelerating voltage Charging Ref: SEM Manual, JEOL

43 Contamination Due to residual gas in the vicinity of the electron probe Leads to reduced contrast and loss in image sharpness Usually caused by scanning a small region for long time Contamination 5 kv Specimen: ITO Ref: SEM Manual, JEOL

44

45 Backscattered Electron Diffraction Diffraction of Backscattered electrons: 1) Channeling contrast, 2) Diffraction patterns (EBSD) Weaker than atomic number contrast required good BSE detector The BSE intensity changes drastically on or around Bragg s condition Poorer spatial resolution

46 EBSD A stationary electron beam strikes a tilted crystalline sample and the diffracted electrons form a pattern on a fluorescent screen. Pattern is characteristic of the crystal structure and orientation of the sample region from which it was generated. Used to measure the crystal orientation, measure grain boundary misorientations, discriminate between different materials, and provide information about local crystalline perfection.

47 A diffraction pattern from nickel collected at 20 kv accelerating voltage

48 Indexing: Kikuchi bands are labelled with the Miller indices of the crystal planes that generated them (red). The planes project onto the screen at the centre of the bands. Kikuchi band intersections are labelled with crystal direction that meets the screen at this point (white). This direction is the zone axis of the planes corresponding to the intersecting Kikuchi bands. The nickel crystal unit cell superimposed on the diffraction pattern in the orientation which generates this pattern. The crystal planes are labelled which correspond to the (2-20) and (020) Kikuchi bands in the diffraction pattern. The Kikuchi band width depends on the d-spacing of the corresponding plane. The (200) plane d-spacing is wider than the (2-20) plane so the Kikuchi bands from (200) planes are narrower than those from (2-20) planes.

49 The symmetry of the crystal is shown in the diffraction pattern. For example, four fold symmetry is shown around the [001] direction by four symmetrically equivalent <013> zone axes. Changes in the crystal orientation result in movement of the diffraction pattern. The simulated diffraction pattern is from a sample tilted 70 to the horizontal and the crystal orientation is viewed along the direction perpendicular to the sample

50

51

52

View of ΣIGMA TM (Ref. 1)

View of ΣIGMA TM (Ref. 1) Overview of the FESEM system 1. Electron optical column 2. Specimen chamber 3. EDS detector [Electron Dispersive Spectroscopy] 4. Monitors 5. BSD (Back scatter detector) 6. Personal Computer 7. ON/STANDBY/OFF

More information

Scanning Electron Microscopy Primer

Scanning Electron Microscopy Primer Scanning Electron Microscopy Primer Bob Hafner This primer is intended as background for the Introductory Scanning Electron Microscopy training offered by the University of Minnesota s Characterization

More information

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts Electron Microscopy 3. SEM Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts 3-1 SEM is easy! Just focus and shoot "Photo"!!! Please comment this picture... Any

More information

Lenses and Apertures of A TEM

Lenses and Apertures of A TEM Instructor: Dr. C.Wang EMA 6518 Course Presentation Lenses and Apertures of A TEM Group Member: Anup Kr. Keshri Srikanth Korla Sushma Amruthaluri Venkata Pasumarthi Xudong Chen Outline Electron Optics

More information

The Basics of Scanning Electron Microscopy

The Basics of Scanning Electron Microscopy The Basics of Scanning Electron Microscopy The small scanning electron microscope is easy to use because almost every variable is pre-set: the acceleration voltage is always 15kV, it has only a single

More information

Electron Microscopy SEM and TEM

Electron Microscopy SEM and TEM Electron Microscopy SEM and TEM Content 1. Introduction: Motivation for electron microscopy 2. Interaction with matter 3. SEM: Scanning Electron Microscopy 3.1 Functional Principle 3.2 Examples 3.3 EDX

More information

7. advanced SEM. Latest generation of SEM SEM

7. advanced SEM. Latest generation of SEM SEM 7. advanced SEM SEM Low voltage SE imaging Condition of the surface, coatings, plasma cleaning Low voltage BSE imaging Polishing for BSE, EDX and EBSD, effect of ion beam etching/polishing 1 Latest generation

More information

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system EDS system Most common X-Ray measurement system in the SEM lab. Major elements (10 wt% or greater) identified in ~10 secs. Minor elements identifiable in ~100 secs. Rapid qualitative and accurate quantitative

More information

Scanning Electron Microscopy: an overview on application and perspective

Scanning Electron Microscopy: an overview on application and perspective Scanning Electron Microscopy: an overview on application and perspective Elvio Carlino Center for Electron Microscopy - IOM-CNR Laboratorio Nazionale TASC - Trieste, Italy Location of the Center for Electron

More information

Ion Beam Sputtering: Practical Applications to Electron Microscopy

Ion Beam Sputtering: Practical Applications to Electron Microscopy Ion Beam Sputtering: Practical Applications to Electron Microscopy Applications Laboratory Report Introduction Electron microscope specimens, both scanning (SEM) and transmission (TEM), often require a

More information

Fundamentals of Scanning Electron Microscopy

Fundamentals of Scanning Electron Microscopy 1 Fundamentals of Scanning Electron Microscopy Weilie Zhou, Robert P. Apkarian, Zhong Lin Wang, and David Joy 1. Introduction The scanning electron microscope (SEM) is one of the most versatile instruments

More information

Physics 441/2: Transmission Electron Microscope

Physics 441/2: Transmission Electron Microscope Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This

More information

Preface Light Microscopy X-ray Diffraction Methods

Preface Light Microscopy X-ray Diffraction Methods Preface xi 1 Light Microscopy 1 1.1 Optical Principles 1 1.1.1 Image Formation 1 1.1.2 Resolution 3 1.1.3 Depth of Field 5 1.1.4 Aberrations 6 1.2 Instrumentation 8 1.2.1 Illumination System 9 1.2.2 Objective

More information

Scanning Electron Microscopy tools for material characterization

Scanning Electron Microscopy tools for material characterization 5th International Workshop on Mechanisms of Vacuum Arcs 02-04/09/2015 Scanning Electron Microscopy tools for material characterization Focus on EBSD for characterisation of dislocation structures Floriane

More information

Forensic Science: The Basics. Microscopy

Forensic Science: The Basics. Microscopy Forensic Science: The Basics Microscopy Chapter 6 Jay A. Siegel,Ph.D. Power point presentation by Greg Galardi, Peru State College, Peru Nebraska Presentation by Greg Galardi, Peru State College CRC Press,

More information

Use the BET (after Brunauer, Emmett and Teller) equation is used to give specific surface area from the adsorption

Use the BET (after Brunauer, Emmett and Teller) equation is used to give specific surface area from the adsorption Number of moles of N 2 in 0.129dm 3 = 0.129/22.4 = 5.76 X 10-3 moles of N 2 gas Module 8 : Surface Chemistry Objectives Lecture 37 : Surface Characterization Techniques After studying this lecture, you

More information

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts Electron Microscopy 3. SEM Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts SEM is easy! Just focus and shoot "Photo"!!! Please comment this picture... Any idea

More information

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture Nanoelectronics 09 Atsufumi Hirohata Department of Electronics 12:00 Wednesday, 4/February/2015 (P/L 006) Quick Review over the Last Lecture ( Field effect transistor (FET) ): ( Drain ) current increases

More information

CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging

CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging CSCI 4974 / 6974 Hardware Reverse Engineering Lecture 8: Microscopy and Imaging Data Acquisition for RE Microscopy Imaging Registration and stitching Microscopy Optical Electron Scanning Transmission Scanning

More information

Vacuum Evaporation Recap

Vacuum Evaporation Recap Sputtering Vacuum Evaporation Recap Use high temperatures at high vacuum to evaporate (eject) atoms or molecules off a material surface. Use ballistic flow to transport them to a substrate and deposit.

More information

Name: Due: September 21 st 2012. Physics 7230 Laboratory 3: High Resolution SEM Imaging

Name: Due: September 21 st 2012. Physics 7230 Laboratory 3: High Resolution SEM Imaging Name: Due: September 21 st 2012 Physics 7230 Laboratory 3: High Resolution SEM Imaging 1. What is meant by the term resolution? How does this differ from other image variables, such as signal to noise

More information

Laue lens for Nuclear Medicine

Laue lens for Nuclear Medicine Laue lens for Nuclear Medicine PhD in Physics Gianfranco Paternò Ferrara, 6-11-013 Supervisor: prof. Vincenzo Guidi Sensors and Semiconductors Lab, Department of Physics and Earth Science, University of

More information

Scanning He + Ion Beam Microscopy and Metrology. David C Joy University of Tennessee, and Oak Ridge National Laboratory

Scanning He + Ion Beam Microscopy and Metrology. David C Joy University of Tennessee, and Oak Ridge National Laboratory Scanning He + Ion Beam Microscopy and Metrology David C Joy University of Tennessee, and Oak Ridge National Laboratory The CD-SEM For thirty years the CD-SEM has been the tool for metrology But now, as

More information

The Focused Ion Beam Scanning Electron Microscope: A tool for sample preparation, two and three dimensional imaging. Jacob R.

The Focused Ion Beam Scanning Electron Microscope: A tool for sample preparation, two and three dimensional imaging. Jacob R. The Focused Ion Beam Scanning Electron Microscope: A tool for sample preparation, two and three dimensional imaging Jacob R. Bowen Contents Components of a FIB-SEM Ion interactions Deposition & patterns

More information

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES BIODIVERSITY I BIOL1051 Microscopy Professor Marc C. Lavoie marc.lavoie@cavehill.uwi.edu MAJOR FUNCTIONS OF MICROSCOPES MAGNIFY RESOLVE: => INCREASE CONTRAST Microscopy 1. Eyepieces 2. Diopter adjustment

More information

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Surface Characterization - Marie-Geneviève Barthés-Labrousse

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Surface Characterization - Marie-Geneviève Barthés-Labrousse SURFACE CHARACTERIZATION Marie-Geneviève Centre d Etudes de Chimie Métallurgique, CNRS, Vitry-sur-Seine, France Keywords: Surface Analysis, Surface imaging, Surface composition, Surface chemical analysis,

More information

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope andras@nist.gov Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope Bin Ming, András E. Vladár and Michael T. Postek National Institute of Standards and Technology

More information

Detailed Alignment Procedure for the JEOL 2010F Transmission Electron Microscope

Detailed Alignment Procedure for the JEOL 2010F Transmission Electron Microscope Detailed Alignment Procedure for the JEOL 2010F Transmission Electron Microscope by Wendy Sarney ARL-MR-603 December 2004 Approved for public release; distribution unlimited. NOTICES Disclaimers The findings

More information

Near-field scanning optical microscopy (SNOM)

Near-field scanning optical microscopy (SNOM) Adviser: dr. Maja Remškar Institut Jožef Stefan January 2010 1 2 3 4 5 6 Fluorescence Raman and surface enhanced Raman 7 Conventional optical microscopy-limited resolution Two broad classes of techniques

More information

Introduction to the Scanning Electron Microscope

Introduction to the Scanning Electron Microscope Introduction to the Scanning Electron Microscope Theory, Practice, & Procedures Prepared by Michael Dunlap & Dr. J. E. Adaskaveg Presented by the FACILITY FOR ADVANCED INSTRUMENTATION, U. C. Davis 1997

More information

ORIENTATION CHARACTERISTICS OF THE MICROSTRUCTURE OF MATERIALS

ORIENTATION CHARACTERISTICS OF THE MICROSTRUCTURE OF MATERIALS ORIENTATION CHARACTERISTICS OF THE MICROSTRUCTURE OF MATERIALS K. Sztwiertnia Polish Academy of Sciences, Institute of Metallurgy and Materials Science, 25 Reymonta St., 30-059 Krakow, Poland MMN 2009

More information

Properties of Electrons, their Interactions with Matter and Applications in Electron Microscopy

Properties of Electrons, their Interactions with Matter and Applications in Electron Microscopy Properties of Electrons, their Interactions with Matter and Applications in Electron Microscopy By Frank Krumeich Laboratory of Inorganic Chemistry, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zurich, Switzerland

More information

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,

More information

bulk 5. Surface Analysis Why surface Analysis? Introduction Methods: XPS, AES, RBS

bulk 5. Surface Analysis Why surface Analysis? Introduction Methods: XPS, AES, RBS 5. Surface Analysis Introduction Methods: XPS, AES, RBS Autumn 2011 Experimental Methods in Physics Marco Cantoni Why surface Analysis? Bulk: structural function Electrical/thermal conduction Volume increases

More information

Usage of AFM, SEM and TEM for the research of carbon nanotubes

Usage of AFM, SEM and TEM for the research of carbon nanotubes Usage of AFM, SEM and TEM for the research of carbon nanotubes K.Safarova *1, A.Dvorak 2, R. Kubinek 1, M.Vujtek 1, A. Rek 3 1 Department of Experimental Physics, Faculty of Science, Palacky University,

More information

Lectures about XRF (X-Ray Fluorescence)

Lectures about XRF (X-Ray Fluorescence) 1 / 38 Lectures about XRF (X-Ray Fluorescence) Advanced Physics Laboratory Laurea Magistrale in Fisica year 2013 - Camerino 2 / 38 X-ray Fluorescence XRF is an acronym for X-Ray Fluorescence. The XRF technique

More information

COMPARISON OF TEXTURE IN COPPER AND ALUMINUM THIN FILMS DETERMINED BY XRD AND EBSD *

COMPARISON OF TEXTURE IN COPPER AND ALUMINUM THIN FILMS DETERMINED BY XRD AND EBSD * 201 COMPARISON OF TEXTURE IN COPPER AND ALUMINUM THIN FILMS DETERMINED BY XRD AND EBSD * J. Müller 1, D. Balzar 1,2, R.H. Geiss 1, D.T. Read 1, and R.R. Keller 1 1 Materials Reliability Division, National

More information

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging Quantitative analysis Ceramics sample Peak deconvolution EDS map Phase analysis Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using

More information

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY 243 CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY B. Chyba, M. Mantler, H. Ebel, R. Svagera Technische Universit Vienna, Austria ABSTRACT The accurate characterization of the spectral distribution

More information

Diffraction Course Series 2015

Diffraction Course Series 2015 Diffraction Course Series 2015 Mark Wainwright Analytical Centre Kensington Campus, Chemical Sciences Building F10, Room G37 The Mark Wainwright Analytical Centre is offering a new series of courses covering

More information

Looking through the fish-eye the Electron Ronchigram. Duncan T.L. Alexander CIME seminar May 24, 2012

Looking through the fish-eye the Electron Ronchigram. Duncan T.L. Alexander CIME seminar May 24, 2012 Looking through the fish-eye the Electron Ronchigram Duncan T.L. Alexander CIME seminar May 24, 2012 Introduction Aim of the seminar: open a discussion on the Electron Ronchigram How is it formed? What

More information

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University Chapter 4 Microscopy, Staining, and Classification 2012 Pearson Education Inc. Lecture prepared by Mindy Miller-Kittrell North Carolina State University Microscopy and Staining 2012 Pearson Education Inc.

More information

Cathode Ray Tube. Introduction. Functional principle

Cathode Ray Tube. Introduction. Functional principle Introduction The Cathode Ray Tube or Braun s Tube was invented by the German physicist Karl Ferdinand Braun in 897 and is today used in computer monitors, TV sets and oscilloscope tubes. The path of the

More information

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012 Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012 You are sitting at your microscope working at high magnification trying to sort out the three-dimensional compartmentalization

More information

Microscopy and Nanoindentation. Combining Orientation Imaging. to investigate localized. deformation behaviour. Felix Reinauer

Microscopy and Nanoindentation. Combining Orientation Imaging. to investigate localized. deformation behaviour. Felix Reinauer Combining Orientation Imaging Microscopy and Nanoindentation to investigate localized deformation behaviour Felix Reinauer René de Kloe Matt Nowell Introduction Anisotropy in crystalline materials Presentation

More information

Introduction to microstructure

Introduction to microstructure Introduction to microstructure 1.1 What is microstructure? When describing the structure of a material, we make a clear distinction between its crystal structure and its microstructure. The term crystal

More information

TOF FUNDAMENTALS TUTORIAL

TOF FUNDAMENTALS TUTORIAL TOF FUNDAMENTALS TUTORIAL Presented By: JORDAN TOF PRODUCTS, INC. 990 Golden Gate Terrace Grass Valley, CA 95945 530-272-4580 / 530-272-2955 [fax] www.rmjordan.com [web] info@rmjordan.com [e-mail] This

More information

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION David Bernard Dage Precision Industries Inc. Fremont, California d.bernard@dage-group.com ABSTRACT The x-ray inspection of PCB assembly processes

More information

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND THE THREE-DIMENSIONAL DISTRIBUTION OF THE RADIANT FLUX DENSITY AT THE FOCUS OF A CONVERGENCE BEAM

More information

X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye

X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US Hanno zur Loye X-rays are electromagnetic radiation of wavelength about 1 Å (10-10 m), which is about the same size as an atom. The

More information

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE 6450 - Dr. Alan Doolittle

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE 6450 - Dr. Alan Doolittle Lecture 12 Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12 Evaporation and Sputtering (Metalization) Evaporation For all devices, there is a need to go from semiconductor to metal.

More information

Energy Dispersive Spectroscopy on the SEM: A Primer

Energy Dispersive Spectroscopy on the SEM: A Primer Energy Dispersive Spectroscopy on the SEM: A Primer Bob Hafner This primer is intended as background for the EDS Analysis on the SEM course offered by the University of Minnesota s Characterization Facility.

More information

EXPERIMENT III EXPERIMENTS WITH AN ELECTRON BEAM

EXPERIMENT III EXPERIMENTS WITH AN ELECTRON BEAM EXPERIMENT III EXPERIMENTS WITH AN ELECTRON BEAM An electron beam is a collection of free electrons, all traveling in approximately the same direction with the approximately the same velocity. While it

More information

Measuring the Point Spread Function of a Fluorescence Microscope

Measuring the Point Spread Function of a Fluorescence Microscope Frederick National Laboratory Measuring the Point Spread Function of a Fluorescence Microscope Stephen J Lockett, PhD Principal Scientist, Optical Microscopy and Analysis Laboratory Frederick National

More information

INTRODUCTION TO THE XL30-FEG SEM. 1.1 The mouse. 1.2. The monitor. Figure 1.1 1. THE USER INTERFACE

INTRODUCTION TO THE XL30-FEG SEM. 1.1 The mouse. 1.2. The monitor. Figure 1.1 1. THE USER INTERFACE INTRODUCTION TO THE XL30-FEG SEM All software used to control the microscope runs in the MS-Windows environment. This environment is loaded on the Windows2000 operating system. However, it is not really

More information

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Standard Test Method for Classification of Film Systems for Industrial Radiography 1 Designation: E 1815 96 (Reapproved 2001) Standard Test Method for Classification of Film Systems for Industrial Radiography 1 This standard is issued under the fixed designation E 1815; the number immediately

More information

Reflection Electron Microscopy and Spectroscopy for Surface Analysis

Reflection Electron Microscopy and Spectroscopy for Surface Analysis Reflection Electron Microscopy and Spectroscopy for Surface Analysis by Zhong Lin Wang 1 Introduction In 1986, E. Ruska was awarded the Nobel Physics Prize for his pioneering work of building the world's

More information

Chapter 7: Basics of X-ray Diffraction

Chapter 7: Basics of X-ray Diffraction Providing Solutions To Your Diffraction Needs. Chapter 7: Basics of X-ray Diffraction Scintag has prepared this section for use by customers and authorized personnel. The information contained herein is

More information

Physics 30 Worksheet # 14: Michelson Experiment

Physics 30 Worksheet # 14: Michelson Experiment Physics 30 Worksheet # 14: Michelson Experiment 1. The speed of light found by a Michelson experiment was found to be 2.90 x 10 8 m/s. If the two hills were 20.0 km apart, what was the frequency of the

More information

How Does One Obtain Spectral +Imaging Data

How Does One Obtain Spectral +Imaging Data How Does One Obtain Spectral +Imaging Data What we observe depends on the instruments that one observes with! In x and γ-ray spectroscopy we have a wide variety of instruments with different properties

More information

Secondary Ion Mass Spectrometry

Secondary Ion Mass Spectrometry Secondary Ion Mass Spectrometry A PRACTICAL HANDBOOK FOR DEPTH PROFILING AND BULK IMPURITY ANALYSIS R. G. Wilson Hughes Research Laboratories Malibu, California F. A. Stevie AT&T Bell Laboratories Allentown,

More information

Light and its effects

Light and its effects Light and its effects Light and the speed of light Shadows Shadow films Pinhole camera (1) Pinhole camera (2) Reflection of light Image in a plane mirror An image in a plane mirror is: (i) the same size

More information

Raman spectroscopy Lecture

Raman spectroscopy Lecture Raman spectroscopy Lecture Licentiate course in measurement science and technology Spring 2008 10.04.2008 Antti Kivioja Contents - Introduction - What is Raman spectroscopy? - The theory of Raman spectroscopy

More information

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.

More information

Lecture 6 Scanning Tunneling Microscopy (STM) General components of STM; Tunneling current; Feedback system; Tip --- the probe.

Lecture 6 Scanning Tunneling Microscopy (STM) General components of STM; Tunneling current; Feedback system; Tip --- the probe. Lecture 6 Scanning Tunneling Microscopy (STM) General components of STM; Tunneling current; Feedback system; Tip --- the probe. Brief Overview of STM Inventors of STM The Nobel Prize in Physics 1986 Nobel

More information

Experiment #5: Qualitative Absorption Spectroscopy

Experiment #5: Qualitative Absorption Spectroscopy Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions

More information

Chapter 17: Light and Image Formation

Chapter 17: Light and Image Formation Chapter 17: Light and Image Formation 1. When light enters a medium with a higher index of refraction it is A. absorbed. B. bent away from the normal. C. bent towards from the normal. D. continues in the

More information

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM

More information

8.1 Radio Emission from Solar System objects

8.1 Radio Emission from Solar System objects 8.1 Radio Emission from Solar System objects 8.1.1 Moon and Terrestrial planets At visible wavelengths all the emission seen from these objects is due to light reflected from the sun. However at radio

More information

E/M Experiment: Electrons in a Magnetic Field.

E/M Experiment: Electrons in a Magnetic Field. E/M Experiment: Electrons in a Magnetic Field. PRE-LAB You will be doing this experiment before we cover the relevant material in class. But there are only two fundamental concepts that you need to understand.

More information

h e l p s y o u C O N T R O L

h e l p s y o u C O N T R O L contamination analysis for compound semiconductors ANALYTICAL SERVICES B u r i e d d e f e c t s, E v a n s A n a l y t i c a l g r o u p h e l p s y o u C O N T R O L C O N T A M I N A T I O N Contamination

More information

Polarization Dependence in X-ray Spectroscopy and Scattering. S P Collins et al Diamond Light Source UK

Polarization Dependence in X-ray Spectroscopy and Scattering. S P Collins et al Diamond Light Source UK Polarization Dependence in X-ray Spectroscopy and Scattering S P Collins et al Diamond Light Source UK Overview of talk 1. Experimental techniques at Diamond: why we care about x-ray polarization 2. How

More information

Experiment: Crystal Structure Analysis in Engineering Materials

Experiment: Crystal Structure Analysis in Engineering Materials Experiment: Crystal Structure Analysis in Engineering Materials Objective The purpose of this experiment is to introduce students to the use of X-ray diffraction techniques for investigating various types

More information

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator. PHYS 222 Spring 2012 Final Exam Closed books, notes, etc. No electronic device except a calculator. NAME: (all questions with equal weight) 1. If the distance between two point charges is tripled, the

More information

X-ray thin-film measurement techniques

X-ray thin-film measurement techniques Technical articles X-ray thin-film measurement techniques II. Out-of-plane diffraction measurements Toru Mitsunaga* 1. Introduction A thin-film sample is two-dimensionally formed on the surface of a substrate,

More information

1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical

More information

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer What is ICP-MS? and more importantly, what can it do? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations. The technique was commercially

More information

The Physics of Energy sources Renewable sources of energy. Solar Energy

The Physics of Energy sources Renewable sources of energy. Solar Energy The Physics of Energy sources Renewable sources of energy Solar Energy B. Maffei Bruno.maffei@manchester.ac.uk Renewable sources 1 Solar power! There are basically two ways of using directly the radiative

More information

How To Understand Light And Color

How To Understand Light And Color PRACTICE EXAM IV P202 SPRING 2004 1. In two separate double slit experiments, an interference pattern is observed on a screen. In the first experiment, violet light (λ = 754 nm) is used and a second-order

More information

This is an author-deposited version published in: http://sam.ensam.eu Handle ID:.http://hdl.handle.net/10985/10324

This is an author-deposited version published in: http://sam.ensam.eu Handle ID:.http://hdl.handle.net/10985/10324 Science Arts & Métiers (SAM) is an open access repository that collects the work of Arts et Métiers ParisTech researchers and makes it freely available over the web where possible. This is an author-deposited

More information

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T. Displays Semiconductor Elements 1 Cathode Ray Tube Basic applications Oscilloscope TV Old monitors 2 1 Idea of Electrostatic Deflection 3 Inside an Electrostatic Deflection Cathode Ray Tube Gun creates

More information

Fraunhofer Diffraction

Fraunhofer Diffraction Physics 334 Spring 1 Purpose Fraunhofer Diffraction The experiment will test the theory of Fraunhofer diffraction at a single slit by comparing a careful measurement of the angular dependence of intensity

More information

Solid State Detectors = Semi-Conductor based Detectors

Solid State Detectors = Semi-Conductor based Detectors Solid State Detectors = Semi-Conductor based Detectors Materials and their properties Energy bands and electronic structure Charge transport and conductivity Boundaries: the p-n junction Charge collection

More information

Atomic Force Microscope and Magnetic Force Microscope Background Information

Atomic Force Microscope and Magnetic Force Microscope Background Information Atomic Force Microscope and Magnetic Force Microscope Background Information Lego Building Instructions There are several places to find the building instructions for building the Lego models of atomic

More information

Project 2B Building a Solar Cell (2): Solar Cell Performance

Project 2B Building a Solar Cell (2): Solar Cell Performance April. 15, 2010 Due April. 29, 2010 Project 2B Building a Solar Cell (2): Solar Cell Performance Objective: In this project we are going to experimentally measure the I-V characteristics, energy conversion

More information

Microscopic Techniques

Microscopic Techniques Microscopic Techniques Outline 1. Optical microscopy Conventional light microscopy, Fluorescence microscopy, confocal/multiphoton microscopy and Stimulated emission depletion microscopy 2. Scanning probe

More information

Coating Technology: Evaporation Vs Sputtering

Coating Technology: Evaporation Vs Sputtering Satisloh Italy S.r.l. Coating Technology: Evaporation Vs Sputtering Gianni Monaco, PhD R&D project manager, Satisloh Italy 04.04.2016 V1 The aim of this document is to provide basic technical information

More information

X Ray Flourescence (XRF)

X Ray Flourescence (XRF) X Ray Flourescence (XRF) Aspiring Geologist XRF Technique XRF is a rapid, relatively non destructive process that produces chemical analysis of rocks, minerals, sediments, fluids, and soils It s purpose

More information

Information about the T9 beam line and experimental facilities

Information about the T9 beam line and experimental facilities Information about the T9 beam line and experimental facilities The incoming proton beam from the PS accelerator impinges on the North target and thus produces the particles for the T9 beam line. The collisions

More information

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL Robert Bagnell 2006 This tutorial covers the following CLSM topics: 1) What is the optical principal behind CLSM? 2) What is the spatial resolution in X, Y,

More information

Tecnai on-line help Working with a FEG 1 FEG_A4.doc Software version 2

Tecnai on-line help Working with a FEG 1 FEG_A4.doc Software version 2 Tecnai on-line help Working with a FEG 1 Tecnai on-line help manual -- Working with a FEG Table of Contents 1 Introduction...2 2 FEG Safety...2 2.1 The column valves...2 3 FEG States...3 4 Starting the

More information

Sensors & Instruments for station. returned samples. Chun Chia Tan

Sensors & Instruments for station. returned samples. Chun Chia Tan Sensors & Instruments for station based materials characterization of returned samples Chun Chia Tan 04/01/2009 Outline Introduction to materials characterization General overview of the equipment used

More information

Electron Microprobe Analysis X-ray spectrometry:

Electron Microprobe Analysis X-ray spectrometry: Electron Microprobe Analysis X-ray spectrometry: 1. X-ray generation and emission 2. X-ray detection and measurement X-ray energy and wavelength E=hν h : Planck's constant (6.626x10-34 Joule.sec or, 6.626x10-34

More information

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100) Low energy ion scattering study of 4 on Cu(1) Chapter 8. Low energy ion scattering study of 4 on Cu(1) 8.1. Introduction For a better understanding of the reconstructed 4 surfaces one would like to know

More information

DOE Solar Energy Technologies Program Peer Review. Denver, Colorado April 17-19, 2007

DOE Solar Energy Technologies Program Peer Review. Denver, Colorado April 17-19, 2007 DOE Solar Energy Technologies Program Peer Review Evaluation of Nanocrystalline Silicon Thin Film by Near-Field Scanning Optical Microscopy AAT-2-31605-05 Magnus Wagener and George Rozgonyi North Carolina

More information

Graphical displays are generally of two types: vector displays and raster displays. Vector displays

Graphical displays are generally of two types: vector displays and raster displays. Vector displays Display technology Graphical displays are generally of two types: vector displays and raster displays. Vector displays Vector displays generally display lines, specified by their endpoints. Vector display

More information

Mass production, R&D Failure analysis. Fault site pin-pointing (EM, OBIRCH, FIB, etc. ) Bottleneck Physical science analysis (SEM, TEM, Auger, etc.

Mass production, R&D Failure analysis. Fault site pin-pointing (EM, OBIRCH, FIB, etc. ) Bottleneck Physical science analysis (SEM, TEM, Auger, etc. Failure Analysis System for Submicron Semiconductor Devices 68 Failure Analysis System for Submicron Semiconductor Devices Munetoshi Fukui Yasuhiro Mitsui, Ph. D. Yasuhiko Nara Fumiko Yano, Ph. D. Takashi

More information

LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008

LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008 LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008 PARTICLE CHARACTERISATION IN EXCIPIENTS, DRUG PRODUCTS AND DRUG SUBSTANCES AUTHOR: HILDEGARD BRÜMMER, PhD, CUSTOMER SERVICE MANAGER, SGS LIFE SCIENCE

More information

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM. Some limitations (disadvantages) of NSOM A trade-off

More information

Understanding astigmatism Spring 2003

Understanding astigmatism Spring 2003 MAS450/854 Understanding astigmatism Spring 2003 March 9th 2003 Introduction Spherical lens with no astigmatism Crossed cylindrical lenses with astigmatism Horizontal focus Vertical focus Plane of sharpest

More information