EqualLogic DCB Configuration Best Practices

Size: px
Start display at page:

Download "EqualLogic DCB Configuration Best Practices"

Transcription

1 EqualLogic DCB Configuration Best Practices A Dell EqualLogic Best Practices Technical White Paper Dell Storage Engineering May 2014

2 Revisions Date February 2013 February 2013 May 2013 May 2014 Description Initial publication Changed PC81xx configuration steps to external SGC link Added Force10 S4820T information Updated links to new Switch Configuration Guides 2014 Dell Inc. All Rights Reserved. Dell, the Dell logo, and other Dell names and marks are trademarks of Dell Inc. in the US and worldwide. All other trademarks mentioned herein are the property of their respective owners. 2 BP1058 EqualLogic DCB Configuration Best Practices

3 Table of Contents 1 Introduction Objective Audience DCB configuration guidelines DCB requirements summary Configuration process overview Enabling DCB and configuring the VLAN Switch configuration Disabling DCB on the SAN DCB configuration verification Priority Group, ETS, and PFC verification Invalid DCB configuration detection Switch specific configuration steps Configuration for switches with DCB support Force10 S Force10 S4820T Force10 MXL PowerConnect 81XX Series Cisco Nexus 5548UP Brocade B Configuration for switches that do not support DCB for EqualLogic PowerConnect 8024, 8024F, and M Cisco Nexus 5010/5020 and Nexus A EqualLogic command line reference for DCB configuration verification B Broadcom 57810S configuration and verification B.1 Broadcom 57810S DCBX willing mode verification B.2 Broadcom 57810S iscsi VLAN configuration B.3 Broadcom 57810S DCB configuration verification BP1058 EqualLogic DCB Configuration Best Practices

4 1 Introduction Data Center Bridging (DCB) is a networking standard that first appeared on Fibre Channel over Ethernet (FCoE) SANs as a method to ensure lossless delivery of Fibre Channel (FC) traffic from Ethernet hosts to FC storage targets. Over recent years, this technology has been extended to deliver similar benefits for iscsi storage solutions and continues to gain acceptance with storage networking device manufacturers and customers. Beginning with Dell EqualLogic Firmware release 5.1 in 2010, Dell introduced DCB for iscsi on all 10 GbE PS Series products. Given that all network elements in a DCB-enabled iscsi SAN need to support DCB, Dell offers PowerEdge converged network adapters (CNAs) and Ethernet switches in the PowerConnect and Force10 product line that support DCB for iscsi. A complete listing of all Ethernet switches and CNAs validated for DCB compliance with EqualLogic can be found in the EqualLogic Compatibility Matrix at Objective The purpose of this document is to provide an overview of the DCB requirements for EqualLogic and to assist with identifying and resolving basic DCB configuration issues in the EqualLogic SAN. This information may be used to ensure that DCB is properly enabled across all devices in the SAN or to ensure that DCB is effectively disabled if it is not required. Note: For an in-depth tutorial of DCB, refer to the Dell white paper, Data Center Bridging: Standards, Behavioral Requirements, and Configuration Guidelines with Dell EqualLogic iscsi SANs at Audience This document is primarily targeted at storage and networking administrators who are responsible for the design, deployment, and maintenance of Dell EqualLogic SANs and related system components. It is assumed that the reader has operational and administrative knowledge of EqualLogic storage, iscsi SAN network design, and related EqualLogic networking best practices. For a comprehensive listing of EqualLogic networking best practices, please refer to the EqualLogic Configuration Guide at 4 BP1058 EqualLogic DCB Configuration Best Practices

5 2 DCB configuration guidelines 2.1 DCB requirements summary It is required that all devices in the EqualLogic SAN support DCB for iscsi when this functionality is enabled. If any device in the SAN does not support DCB, then DCB must be disabled at the switches for the entire SAN. Once all devices in the SAN are DCB compliant, then DCB can be re-enabled. Devices that are designated as DCB Supported in the EqualLogic Compatibility Matrix have been fully validated by Dell to ensure compatibility for EqualLogic SANs. In deployments that contain devices not listed in the EqualLogic Compatibility Matrix, ensure that all Ethernet switches and CNAs in the SAN adhere to the following DCB standards: Support for DCB versions 1.01 (also known as Baseline DCBx or CEE DCBx) or IEEE DCB. Data Center Bridging Exchange (DCBX) DCB protocol that performs discovery, configuration, and mismatch resolution using Link Layer Discovery Protocol (LLDP). iscsi application priority Support for the iscsi protocol in the application priority DCBX Type Length Value (TLV). Advertises the priority value (IEEE 802.1p CoS, PCP field in VLAN tag) for iscsi protocol. End devices identify and tag Ethernet frames containing iscsi data with this priority value. Enhanced Transmission Selection (ETS) Provides minimum, guaranteed bandwidth allocation per traffic class/priority group during congestion and permits additional bandwidth allocation during non-congestion. Priority-based Flow Control (PFC) - Independent traffic priority pausing and enablement of lossless packet buffers/queuing for iscsi. 2.2 Configuration process overview Important: With all network configuration changes, there is the possibility of service interruptions. Network changes required to properly configure DCB for EqualLogic will result in a temporary loss of connectivity. Therefore, Dell strongly recommends that all network environment changes are performed during a planned maintenance window. This section provides general steps to configure DCB for EqualLogic and Section 3 contains detailed steps for specific Dell and other switch models. These steps apply to both new deployments and those deployments that have DCB improperly configured. It is important to verify that all components in the SAN are listed in the EqualLogic Compatibility Matrix as DCB Supported or that the components support all EqualLogic requirements for DCB. If multiple switches are in the path between iscsi Hosts and EqualLogic arrays, then all configuration steps below must be applied to these switches. For SAN deployments with two or more switch hops, please refer to Data Center Bridging: Standards, Behavioral Requirements, and Configuration Guidelines with Dell EqualLogic iscsi SANs for additional configuration guidance and considerations at: 5 BP1058 EqualLogic DCB Configuration Best Practices

6 When configuring DCB on a new array member, ensure the switch is setup properly first. The CLI setup wizard or the Remote Setup Wizard will detect the switch is DCB capable and prompt for the required configuration information, including the VLAN ID, during setup. To configure DCB on an existing EqualLogic array member: 1. Disable DCB on the switch, if it is enabled. 2. Verify that all CNAs are enabled and configured in DCB willing mode. 3. Verify that the EqualLogic array has DCB enabled (Note: This is enabled by default and should never be disabled). 4. Enter a VLAN ID from in Group Manager. With firmware v7 and later, the VLAN ID will default to 2 when DCB is detected on the switch. 5. On the switch, create a VLAN in trunk mode for all switch ports connected to arrays and iscsi hosts with the same VLAN ID configured on the array. 6. Configure all CNAs with same VLAN ID configured on the array. 7. On the switch, configure Priority Groups/ETS, PFC, and iscsi application priority on all ports connected to EqualLogic arrays and iscsi host CNAs. The same should be configured for any switch interconnects (LAGs, VLTi, vpc, and others) 8. Enable DCB on the switch. 9. Verify all DCB configuration and operational parameters on array ports via Group Manager. 10. Verify DCB operational parameters on CNAs using the respective management application. Steps 1, 3, 4, 7, 8, and 9 are outlined in the following section. Appendix B provides additional guidance for steps 2, 6, and 10 using the Broadcom 57810S CNA. 2.3 Enabling DCB and configuring the VLAN The DCB VLAN setting can be found in the Group Manager Summary page as seen below. For firmware versions prior to 7.x, the Enable DCB checkbox should always be checked. With firmware version 7.x and later, the checkbox is no longer displayed and DCB is always enabled and in willing mode. 6 BP1058 EqualLogic DCB Configuration Best Practices

7 Figure 1 DCB VLAN setting from Group Manager v7 Important: At no point should DCB be disabled on the array. This is important for several reasons: DCB is enabled on 10 Gb capable arrays by default and in willing mode. It can only be disabled via CLI and should only be done if instructed by Dell support. Disabling DCB on the array does not ensure that DCB is fully disabled in the SAN and flow control may not be enabled between the switch ports, hosts, and arrays. When DCB is enabled, the arrays receive DCB configuration information from the switch and will continue to provide real-time DCB status which can be used to verify the configuration. If the attached switch ports are not DCB enabled, then the array ports will operate in standard (802.3x) flow control mode. Next, a valid VLAN ID must be entered. The range of recommended values is However, verify that the VLAN ID choice does not conflict with any default or reserved IDs for your specific switch make and model. With firmware v7 and later, the VLAN ID will default to 2 when DCB is detected on the switch. Important: When DCB is enabled on the switch, it is necessary to configure a non-default VLAN on the array, switch, and all host ports that are part of the EqualLogic SAN. VLAN IDs 0 and 1 should not be used as these may be the default or reserved VLAN for some switches, and as such, may forward frames untagged (with no VLAN tagging). VLAN tagging is required to fully support DCB. 2.4 Switch configuration For switch configuration steps, refer to Section 3 and find your specific switch model. If the specific switch is not listed, consult with your switch vendor to confirm the DCB support requirements for EqualLogic and obtain instructions for configuring (or disabling) DCB on the switch as needed. 7 BP1058 EqualLogic DCB Configuration Best Practices

8 2.5 Disabling DCB on the SAN When DCB functionality is not required for the SAN deployment, DCB must be disabled on all switches in the SAN. Once DCB is disabled on the SAN, the attached EqualLogic arrays and CNAs will no longer receive DCBx messages from the attached switches, effectively disabling DCB functionality on the SAN completely. Configuration steps for disabling DCB can also be found in Section 3. Important: If DCB is disabled on the switch, ensure that 802.3x flow control is enabled on all switch ports attached to the EqualLogic arrays and iscsi hosts. EqualLogic best practices recommend a minimum of RX flow control on the switch ports. Also it is assumed that the switches are dedicated for SAN traffic alone when DCB is disabled. Important: If DCB is disabled on a switch, then all DCB functionality will be disabled, including support for other protocols such as FCoE. Mixing of FCoE and iscsi on the same converged fabric is not recommended and not supported by Dell. Note: VLAN tagging is only supported when DCB mode is fully enabled and configured. If DCB is disabled on the switch, switch ports must be configured as untagged or as access ports (or left in the native VLAN). 2.6 DCB configuration verification The following sections show how to verify the DCB configuration of a switch via the EqualLogic Group Manager. Equivalent methods for verifying the configuration via the command line interface (CLI) are provided in Appendix A Priority Group, ETS, and PFC verification To determine what configuration steps in Section 2 are needed to properly configure switches and correct the error condition, verify the following information in Group Manager. 1. In Group Manager, click a member array and go to the Network tab. 2. Right-click on each 10 Gb interface (for example eth0) and click DCB Details to display the dialog box shown below. 8 BP1058 EqualLogic DCB Configuration Best Practices

9 3. From these details, verify the following: a. Column 1: For the iscsi Traffic Class Group (Group 1, in this example), only iscsi is present (no other traffic classes should appear, such as FCoE). b. Column 2: ETS % from 1 to 100% (recommend 50% as an initial setting). c. Column 3: Priority level for iscsi is 4 (recommended). d. Column 4: Lossless state for iscsi equals PFC ON for priority Repeat this verification for all 10 Gb array interfaces in the group Invalid DCB configuration detection A new capability released with version 6.0 of the EqualLogic firmware automatically detects if there is an invalid configuration state on the Ethernet switch attached to the EqualLogic array due to the following conditions: PFC is configured (PFC TLV received) iscsi is using a priority group which is not PFC enabled (lossless) This state will result in a warning message that will be displayed at the bottom of the EqualLogic Group Manager interface as shown in Figure 3. Figure 2 Invalid DCB configuration detection warning message in Group Manager v7 If a switch does not support the iscsi TLV, it may not be possible to properly classify the iscsi traffic and assign it to a priority group and enable DCB Priority-based Flow Control. In this case, the array will place all iscsi frames in default priority 0. Typically, priority 0 will not have PFC enabled on the switch, which means that iscsi traffic would be treated with the same priority as all other traffic or in some cases, with a 9 BP1058 EqualLogic DCB Configuration Best Practices

10 lower priority. It is also possible that even when the iscsi TLV is supported by the switch, the iscsi priority may not have PFC enabled for that priority. Upon detection of either of these conditions, the array will issue a warning message that Ethernet flow control has been disabled on one or more interfaces. Operation with no flow control may cause performance degradation and service interruptions. Refer to subsequent sections in this document for information on corrective actions. Figure 3 Invalid DCB configuration detection warning message in Group Manager v6 In addition to this warning message, a more detailed message will appear in the event log and CLI as shown in these examples: Firmware Versions up to 6.0.3: Interface eth0 has negotiated DCB Priority-based Flow Control with the switch. However, the switch did not configure iscsi traffic for a lossless priority. No Ethernet flow control is enabled for iscsi on this interface. Firmware versions and higher: Interface eth0 has detected an invalid switch configuration. All iscsi initiators and targets connected to this switch will have no flow control for iscsi until this is corrected. Firmware version and higher: An invalid switch configuration has been detected. This issue must be corrected in the network infrastructure. Refer to the document located at: 10 BP1058 EqualLogic DCB Configuration Best Practices

11 3 Switch specific configuration steps In this section, switch-specific commands are provided to correctly configure DCB for the EqualLogic SAN or disable it completely if DCB is not required. This is not a comprehensive set of configuration commands for EqualLogic deployments; it is only intended to address the DCB configuration aspect of switches within the EqualLogic SAN. 3.1 Configuration for switches with DCB support The following switches feature DCB with the requirements necessary to fully support EqualLogic storage systems. These switches can be configured for DCB mode or as a dedicated SAN switch with standard link-level (802.3x) flow control Force10 S4810 Refer to the Dell Force10 S4810 Switch Configuration Guide for instructions related to DCB or non-dcb configuration at Force10 S4820T Refer to the Dell Force10 S4820TSwitch Configuration Guide for instructions related to DCB or non-dcb configuration at Force10 MXL Refer to the Dell Force10 MXL 10/40 GbE Blade Switch Configuration Guide for instructions related to DCB or non-dcb configuration at PowerConnect 81XX Series Refer to the Dell PowerConnect 8100Series Switch Configuration Guide for instructions related to DCB or non-dcb configuration at Cisco Nexus 5548UP Refer to the Cisco Nexus 5548-UP Switch Configuration Guide for instructions related to DCB or non- DCB configuration at 11 BP1058 EqualLogic DCB Configuration Best Practices

12 3.1.6 Brocade B8000 Refer to the Brocade B8000 Switch Configuration Guide for instructions related to DCB or non-dcb configuration at Configuration for switches that do not support DCB for EqualLogic The following switches do not fully support DCB requirements for EqualLogic, so DCB must be disabled on these SAN switches. Important: If DCB is disabled on a switch, then all DCB functionality will be disabled, including support for other protocols such as FCoE. Mixing of FCoE and iscsi on the same converged fabric is not recommended and not supported by Dell PowerConnect 8024, 8024F, and M8024 The first step in configuring this line of switches is to first verify the firmware version installed is or higher. Note: If an earlier firmware version is installed, it will not be possible to fully disable DCB on the switch and correct the invalid flow control condition on the arrays and hosts. Upgrade instructions can be found under the corresponding product firmware download pages at To disable DCB, refer to the following guide: Cisco Nexus 5010/5020 and Nexus 7000 The Cisco Nexus 5010/5020 and Nexus 7000 family enables DCB by default, but it does not support the iscsi TLV. Furthermore, Cisco does not provide a method for fully disabling DCB on the switch. Note: All firmware versions do not support DCB with iscsi TLV. DCB support on these switches is for FCoE only. DCB functionality can be disabled on the Nexus 5000 and 7000 switches by disabling LLDP on all ports that connect to EqualLogic array controller ports. This essentially prevents the transmission of DCBX advertisements to the storage system. 12 BP1058 EqualLogic DCB Configuration Best Practices

13 A EqualLogic command line reference for DCB configuration verification From the CLI (GroupAdmin login), the following commands can be executed to obtain the same information that is presented in the Group Manager GUI: show grpparams (Display Global DCB and VLAN status): PG1> show grpparams Group Information Name: PG1 Group-Ipaddress: Group-Mgmt-Gateway: Def-Snap-Reserve: 100% Def-Snap-Warn: 10% Def-Snap-Depletion: delete-oldest Def-Thin-Growth-Warn: 60% Def-Thin-Growth-Max: 100% DateAndTime: Fri Nov 9 13:32: TimeZone: America/New_York Description: Def-Iscsi-Prefix: Def-Iscsi-Alias: yes iqn com.equallogic Info-Messages: enabled Webaccess: enabled Webaccess-noencrypt: enabled Cliaccess-SSH: enabled Cliaccess-Telnet: enabled -Notify: disabled Syslog-Notify: disabled isns-server-list: -List: NtpServers: Smtp-Server-List: DNS-Server-List: DNS-Suffix-List: Syslog-Server-List: Target-Auth-UserName: Target-Auth-Password: Zphr8HHZj2PJX22H BbH822Bx2xXpBRJZ -From: Location: default Conn-Balancing: enabled Discovery-Use-Chap: disabled -Contact: Perf-balancing: enabled Disallow-Downgrades: yes Management-Ipaddress: SSH-V1-Protocol: enabled Standby-Button: disabled FTP-service: enabled Def-DCB-VLAN-Id: 100 DCB: enabled Crypto-Legacy-Protocols: enabled Thermal-Shutdown: enabled Session-Idle-Timeout: 0 Volume-Recovery: enabled Session-Banner-Enable: disabled Session-Idle-Timeout-Enable: disabled Def-Snapshot-Borrow: disabled member select <array-name> eth show (Display DCB ON/OFF): The example below is from an EqualLogic PS6110, so eth0 is the iscsi port and eth1 is the management port which shows the DCB as off for the management port. PG1> member select P1 eth show Name iftype ifspeed Mtu Ipaddress Status Errors DCB eth0 ethernetcsmacd 10 Gbps up 0 on eth1 ethernetcsmacd 100 Mbps up 0 off 13 BP1058 EqualLogic DCB Configuration Best Practices

14 member select <array-name> eth select 0 dcb show (Display DCB details): PG1> member select P1 eth select 0 dcb show Eth DCB Information Name: eth0 DCB: on Lossless-Priorities: on Traffic-Classes: on Congestion Notification: off iscsi-priority: 4 member select <array-name> eth select 0 dcb lossless-priority show (Display Lossless Priority configuration): PG1> member select P1 eth select 0 dcb lossless-priority show Priority Status 0 off 1 off 2 off 3 off 4 on 5 off 6 off 7 off member select <array-name> eth select 0 dcb traffic-class show (Display Traffic Classes): PG1> member select P1 eth select 0 dcb traffic-class show Traffic Bandwidth Priorities Class % 50% 4 0,1,2,3,5,6,7 14 BP1058 EqualLogic DCB Configuration Best Practices

15 B Broadcom 57810S configuration and verification B.1 Broadcom 57810S DCBX willing mode verification Figure 4 below shows a screen shot from the Broadcom Advanced Control Suite (BACS). This is applicable to the Broadcom 57810S Dual-Port 10 GbE SFP+ adapter and the Broadcom 57810S Dual-Port 10 GbE KR Blade Converged Mezzanine Card on Windows Server 2008 R2 SP1. The parameter local machine willing indicates the willing mode state and is enabled by default. Figure 4 Initiator willing mode configuration In this figure, the adapter is configured with willing mode enabled by default. Also the local DCBX settings are shown in the default configuration. These settings include the priority and PFC values for FCoE and iscsi. This also includes the priority groups with their bandwidth allocation and priority mapping. Once the adapter port establishes an operational link with a peer switch port and receives the switch DCBX settings, it will use those settings for DCB operations. The local settings will not be operational at that point. The default local DCBX setting can be changed by overriding them. 15 BP1058 EqualLogic DCB Configuration Best Practices

16 B.2 Broadcom 57810S iscsi VLAN configuration The figure below illustrates the VLAN configuration for iscsi traffic on the adapter port. Figure 5 Initiator VLAN ID configuration B.3 Broadcom 57810S DCB configuration verification The image below is the screen shot from the Broadcom Advanced Control Suite. This is applicable to the Broadcom 57810S Dual-Port 10 GbE SFP+ adapter and the Broadcom 57810S Dual-Port 10 GbE KR Blade Converged Mezzanine Card on Windows Server 2008 R2 SP1. The DCB parameters shown are the values advertised by the switch peer and accepted by the NIC port. It also indicates the DCB operational state for each feature. Figure 6 DCBX operation state and configuration verification 16 BP1058 EqualLogic DCB Configuration Best Practices

17 The local and remote DCBX settings are displayed in the DCBX Advanced section of the BACS, see Figure 7. Figure 7 Advanced DCB operation state and configuration verification 17 BP1058 EqualLogic DCB Configuration Best Practices

Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering October 2015 A Dell Deployment and Configuration Guide Revisions Date February 2013 October 2013 March 2014

More information

Network Configuration Example

Network Configuration Example Network Configuration Example Configuring DCBX Application Protocol TLV Exchange Published: 2014-01-10 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 USA 408-745-2000 www.juniper.net

More information

Converged Networking Solution for Dell M-Series Blades. Spencer Wheelwright

Converged Networking Solution for Dell M-Series Blades. Spencer Wheelwright Converged Networking Solution for Dell M-Series Blades Authors: Reza Koohrangpour Spencer Wheelwright. THIS SOLUTION BRIEF IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL

More information

HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios

HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios Part number 603028-003 Third edition August 2010 Copyright 2009,2010 Hewlett-Packard Development Company, L.P.

More information

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance This white paper compares the performance of blade-to-blade network traffic between two enterprise blade solutions: the Dell

More information

Accelerating Development and Troubleshooting of Data Center Bridging (DCB) Protocols Using Xgig

Accelerating Development and Troubleshooting of Data Center Bridging (DCB) Protocols Using Xgig White Paper Accelerating Development and Troubleshooting of The new Data Center Bridging (DCB) protocols provide important mechanisms for enabling priority and managing bandwidth allocations between different

More information

Active Fabric Manager (AFM) Plug-in for VMware vcenter Virtual Distributed Switch (VDS) CLI Guide

Active Fabric Manager (AFM) Plug-in for VMware vcenter Virtual Distributed Switch (VDS) CLI Guide Active Fabric Manager (AFM) Plug-in for VMware vcenter Virtual Distributed Switch (VDS) CLI Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use

More information

Converging Data Center Applications onto a Single 10Gb/s Ethernet Network

Converging Data Center Applications onto a Single 10Gb/s Ethernet Network Converging Data Center Applications onto a Single 10Gb/s Ethernet Network Explanation of Ethernet Alliance Demonstration at SC10 Contributing Companies: Amphenol, Broadcom, Brocade, CommScope, Cisco, Dell,

More information

Configuring Cisco Nexus 5000 Switches Course DCNX5K v2.1; 5 Days, Instructor-led

Configuring Cisco Nexus 5000 Switches Course DCNX5K v2.1; 5 Days, Instructor-led Configuring Cisco Nexus 5000 Switches Course DCNX5K v2.1; 5 Days, Instructor-led Course Description Configuring Cisco Nexus 5000 Switches (DCNX5K) v2.1 is a 5-day ILT training program that is designed

More information

3G Converged-NICs A Platform for Server I/O to Converged Networks

3G Converged-NICs A Platform for Server I/O to Converged Networks White Paper 3G Converged-NICs A Platform for Server I/O to Converged Networks This document helps those responsible for connecting servers to networks achieve network convergence by providing an overview

More information

OneCommand Manager Application for Windows Release Notes

OneCommand Manager Application for Windows Release Notes OneCommand Manager Application for Windows Release Notes Version: 6.2.10.3 System: Windows Server 2008, Windows Server 2008 R2, and Windows Server 2012: x64 versions, Enterprise and Server Core installation

More information

Ethernet Fabric Requirements for FCoE in the Data Center

Ethernet Fabric Requirements for FCoE in the Data Center Ethernet Fabric Requirements for FCoE in the Data Center Gary Lee Director of Product Marketing glee@fulcrummicro.com February 2010 1 FCoE Market Overview FC networks are relatively high cost solutions

More information

Compellent Storage Center

Compellent Storage Center Compellent Storage Center Microsoft Multipath IO (MPIO) Best Practices Guide Dell Compellent Technical Solutions Group October 2012 THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY

More information

FIBRE CHANNEL OVER ETHERNET

FIBRE CHANNEL OVER ETHERNET FIBRE CHANNEL OVER ETHERNET A Review of FCoE Today ABSTRACT Fibre Channel over Ethernet (FcoE) is a storage networking option, based on industry standards. This white paper provides an overview of FCoE,

More information

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router April 12, 2012 Table of Contents 1.0 Introduction... 4 2.0 Chelsio Unified Storage Router (USR) SAS-to-...

More information

Ethernet: THE Converged Network Ethernet Alliance Demonstration as SC 09

Ethernet: THE Converged Network Ethernet Alliance Demonstration as SC 09 Ethernet: THE Converged Network Ethernet Alliance Demonstration as SC 09 Authors: Amphenol, Cisco, Dell, Fulcrum Microsystems, Intel, Ixia, JDSU, Mellanox, NetApp, Panduit, QLogic, Spirent, Tyco Electronics,

More information

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

How To Evaluate Netapp Ethernet Storage System For A Test Drive

How To Evaluate Netapp Ethernet Storage System For A Test Drive Performance evaluation sponsored by NetApp, Inc. Introduction Ethernet storage is advancing towards a converged storage network, supporting the traditional NFS, CIFS and iscsi storage protocols and adding

More information

DELL EQUALLOGIC PS SERIES NETWORK PERFORMANCE GUIDELINES

DELL EQUALLOGIC PS SERIES NETWORK PERFORMANCE GUIDELINES TECHNICAL REPORT DELL EQUALLOGIC PS SERIES NETWORK PERFORMANCE GUIDELINES ABSTRACT This Technical Report describes network configuration requirements and recommendations for high performance and reliability

More information

Configuring a FlexPod for iscsi Boot

Configuring a FlexPod for iscsi Boot Configuring a FlexPod for iscsi Boot Christopher Nickl World Wide Technology 12/15/2011 Table of Contents Introduction... 2 Prerequisites... 2 Overview... 2 Installation... 3 Configuring the UCS Part 1...

More information

Deploying Silver Peak VXOA Physical And Virtual Appliances with Dell EqualLogic Isolated iscsi SANs including Dell 3-2-1

Deploying Silver Peak VXOA Physical And Virtual Appliances with Dell EqualLogic Isolated iscsi SANs including Dell 3-2-1 Deploying Silver Peak VXOA Physical And Virtual Appliances with Dell EqualLogic Isolated iscsi SANs including Dell 3-2-1 Tech Note June 2012 This tech note describes the deployment of Silver Peak physical

More information

Integrating 16Gb Fibre Channel and 10GbE Technologies with Current Infrastructure

Integrating 16Gb Fibre Channel and 10GbE Technologies with Current Infrastructure Integrating 16Gb Fibre Channel and 10GbE Technologies with Current Infrastructure Agenda Benefits of Converging Fibre Channel and Ethernet Why Separate Networks, Separate Technologies Enabling Convergence

More information

Apple Airport Extreme Base Station V4.0.8 Firmware: Version 5.4

Apple Airport Extreme Base Station V4.0.8 Firmware: Version 5.4 1. APPLE AIRPORT EXTREME 1.1 Product Description The following are device specific configuration settings for the Apple Airport Extreme. Navigation through the management screens will be similar but may

More information

Abstract. Avaya Solution & Interoperability Test Lab

Abstract. Avaya Solution & Interoperability Test Lab Avaya Solution & Interoperability Test Lab Sample Configuration for using Link Layer Discovery Protocol (LLDP) with Cisco Catalyst 4500 or 3750 Switches for VLAN Assignment for Avaya 9600 and 1600 Series

More information

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev. Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of

More information

over Ethernet (FCoE) Dennis Martin President, Demartek

over Ethernet (FCoE) Dennis Martin President, Demartek A Practical Guide to Fibre Channel over Ethernet (FCoE) Dennis Martin President, Demartek Demartek Company Overview Industry analysis with on-site test lab Lab includes servers, networking and storage

More information

Juniper Networks QFX3500

Juniper Networks QFX3500 Implementation Guide Juniper Networks QFX3500 Switch and QLogic Converged Network Implementation Guide Copyright 2012, Juniper Networks, Inc. 1 Table of Contents Introduction...3 Implementing Converged

More information

Data Center Convergence. Ahmad Zamer, Brocade

Data Center Convergence. Ahmad Zamer, Brocade Ahmad Zamer, Brocade SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies and individual members may use this material in presentations

More information

Dell Networking S5000: The Building Blocks of Unified Fabric and LAN/SAN Convergence. Technical Whitepaper

Dell Networking S5000: The Building Blocks of Unified Fabric and LAN/SAN Convergence. Technical Whitepaper Dell Networking S5000: The Building Blocks of Unified Fabric and LAN/SAN Convergence Dell Technical Marketing Data Center Networking May 2013 THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY AND MAY CONTAIN

More information

Dell EqualLogic Configuration Guide

Dell EqualLogic Configuration Guide Dell EqualLogic Configuration Guide Dell Storage Engineering Configure unified block and file storage solutions based on EqualLogic PS Series arrays and the FS Series Family of NAS Appliances. Recommendations

More information

A Whitepaper on. Building Data Centers with Dell MXL Blade Switch

A Whitepaper on. Building Data Centers with Dell MXL Blade Switch A Whitepaper on Building Data Centers with Dell MXL Blade Switch Product Management Dell Networking October 2012 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS

More information

StarWind iscsi SAN: Configuring Global Deduplication May 2012

StarWind iscsi SAN: Configuring Global Deduplication May 2012 StarWind iscsi SAN: Configuring Global Deduplication May 2012 TRADEMARKS StarWind, StarWind Software, and the StarWind and StarWind Software logos are trademarks of StarWind Software that may be registered

More information

Virtualizing the SAN with Software Defined Storage Networks

Virtualizing the SAN with Software Defined Storage Networks Software Defined Storage Networks Virtualizing the SAN with Software Defined Storage Networks Introduction Data Center architects continue to face many challenges as they respond to increasing demands

More information

CCT vs. CCENT Skill Set Comparison

CCT vs. CCENT Skill Set Comparison Operation of IP Data Networks Recognize the purpose and functions of various network devices such as Routers, Switches, Bridges and Hubs Select the components required to meet a given network specification

More information

Direct Attached Storage

Direct Attached Storage , page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel

More information

Abstract. Avaya Solution & Interoperability Test Lab

Abstract. Avaya Solution & Interoperability Test Lab Avaya Solution & Interoperability Test Lab Sample Configuration for using Link Layer Discovery Protocol (LLDP) with Cisco Catalyst 4500 or 3750 Switches for VLAN assignment to Avaya 4600 Series IP Telephones

More information

Fibre Channel Over and Under

Fibre Channel Over and Under Fibre Channel over : A necessary infrastructure convergence By Deni Connor, principal analyst April 2008 Introduction Consolidation of IT datacenter infrastructure is happening in all forms. IT administrators

More information

iscsi Top Ten Top Ten reasons to use Emulex OneConnect iscsi adapters

iscsi Top Ten Top Ten reasons to use Emulex OneConnect iscsi adapters W h i t e p a p e r Top Ten reasons to use Emulex OneConnect iscsi adapters Internet Small Computer System Interface (iscsi) storage has typically been viewed as a good option for small and medium sized

More information

ESX Server 3 Configuration Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5

ESX Server 3 Configuration Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5 ESX Server 3 Configuration Guide Update 2 and later for ESX Server 3.5 and VirtualCenter 2.5 This document supports the version of each product listed and supports all subsequent versions until the document

More information

STORAGE SIMPLIFIED: INTEGRATING DELL EQUALLOGIC PS SERIES STORAGE INTO YOUR HP BLADE SERVER ENVIRONMENT

STORAGE SIMPLIFIED: INTEGRATING DELL EQUALLOGIC PS SERIES STORAGE INTO YOUR HP BLADE SERVER ENVIRONMENT STORAGE SIMPLIFIED: INTEGRATING DELL EQUALLOGIC PS SERIES STORAGE INTO YOUR HP BLADE SERVER ENVIRONMENT A Principled Technologies reference architecture commissioned by Dell Inc. TABLE OF CONTENTS Table

More information

QLogic 10GbE 3GCNA Lab

QLogic 10GbE 3GCNA Lab QLogic 10GbE 3GCNA Lab Lab Overview Designed to provide an overview of the QLogic 8200 Series converged Network Adapter (CNA), this guide outlines the setup, installation, configuration and instructions

More information

StorSimple Appliance Quick Start Guide

StorSimple Appliance Quick Start Guide StorSimple Appliance Quick Start Guide 5000 and 7000 Series Appliance Software Version 2.1.1 (2.1.1-267) Exported from Online Help on September 15, 2012 Contents Getting Started... 3 Power and Cabling...

More information

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance CHAPTER 5 Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance This chapter describes how to configure the switch ports and VLAN interfaces of the ASA 5505 adaptive

More information

138 Configuration Wizards

138 Configuration Wizards 9 Configuration Wizards 9.1 Introduction to Wizards ACP ThinManager uses wizards for configuration. Wizards take two forms. List Wizards associate Terminal Servers and ThinManager Servers with their IP

More information

Unified Storage Networking

Unified Storage Networking Unified Storage Networking Dennis Martin President Demartek Demartek Company Overview Industry analysis with on-site test lab Lab includes servers, networking and storage infrastructure Fibre Channel:

More information

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server How to deploy Converged Networking with VMware ESX Server 3.5 Using Emulex FCoE Technology Table of Contents Introduction...

More information

Monitoring Traffic. Traffic Monitoring. This chapter includes the following sections:

Monitoring Traffic. Traffic Monitoring. This chapter includes the following sections: Monitoring Traffic This chapter includes the following sections: Traffic Monitoring, page 1 Guidelines and Recommendations for Traffic Monitoring, page 2 Creating an Ethernet Traffic Monitoring Session,

More information

Data Center Bridging Plugfest

Data Center Bridging Plugfest Data Center Bridging Plugfest November 2010 Page 1 Table of Contents 1 Introduction & Background Error! Bookmark not defined. 1.1 Introduction... 4 1.2 DCB Plugfest Objectives and Participants... 4 1.3

More information

Frequently Asked Questions. 57712-k. Third-party information brought to you courtesy of Dell. NIC Partitioning (NPAR) FAQs

Frequently Asked Questions. 57712-k. Third-party information brought to you courtesy of Dell. NIC Partitioning (NPAR) FAQs Frequently Asked Questions 57712-k Third-party information brought to you courtesy of Dell NIC Partitioning (NPAR) FAQs 2CS57712-K-FAQ100-R 5300 California Avenue Irvine, CA 92617 Phone: 949-926-5000 Fax:

More information

Adding Traffic Sources to a Monitoring Session, page 7 Activating a Traffic Monitoring Session, page 8 Deleting a Traffic Monitoring Session, page 9

Adding Traffic Sources to a Monitoring Session, page 7 Activating a Traffic Monitoring Session, page 8 Deleting a Traffic Monitoring Session, page 9 This chapter includes the following sections: Traffic Monitoring, page 1 Guidelines and Recommendations for Traffic Monitoring, page 2 Creating an Ethernet Traffic Monitoring Session, page 3 Setting the

More information

vsphere Networking ESXi 5.0 vcenter Server 5.0 EN-000599-01

vsphere Networking ESXi 5.0 vcenter Server 5.0 EN-000599-01 ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

Cisco Nexus 1000V Virtual Ethernet Module Software Installation Guide, Release 4.0(4)SV1(1)

Cisco Nexus 1000V Virtual Ethernet Module Software Installation Guide, Release 4.0(4)SV1(1) Cisco Nexus 1000V Virtual Ethernet Module Software Installation Guide, Release 4.0(4)SV1(1) September 17, 2010 Part Number: This document describes how to install software for the Cisco Nexus 1000V Virtual

More information

Brocade Network Advisor: CLI Configuration Manager

Brocade Network Advisor: CLI Configuration Manager Brocade Network Advisor: CLI Configuration Manager Brocade Network Advisor is a unified network management platform to manage the entire Brocade network, including both SAN and IP products. This technical

More information

Dell EqualLogic Best Practices Series. Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference

Dell EqualLogic Best Practices Series. Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference Dell EqualLogic Best Practices Series Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference Storage Infrastructure and Solutions Engineering Dell Product Group

More information

Configuring Network QoS

Configuring Network QoS CHAPTER 8 This chapter describes how to configure a network qos policy for the Cisco NX-OS device in the Data Center Bridging (DCB) network. This chapter includes the following sections: Note This chapter

More information

Course. Contact us at: Information 1/8. Introducing Cisco Data Center Networking No. Days: 4. Course Code

Course. Contact us at: Information 1/8. Introducing Cisco Data Center Networking No. Days: 4. Course Code Information Price Course Code Free Course Introducing Cisco Data Center Networking No. Days: 4 No. Courses: 2 Introducing Cisco Data Center Technologies No. Days: 5 Contact us at: Telephone: 888-305-1251

More information

Integrating ConnectWise Service Desk Ticketing with the Cisco OnPlus Portal

Integrating ConnectWise Service Desk Ticketing with the Cisco OnPlus Portal Integrating ConnectWise Service Desk Ticketing with the Cisco OnPlus Portal This Application Note explains how to configure ConnectWise PSA (Professional Service Automation) application settings and Cisco

More information

Fiber Channel Over Ethernet (FCoE)

Fiber Channel Over Ethernet (FCoE) Fiber Channel Over Ethernet (FCoE) Using Intel Ethernet Switch Family White Paper November, 2008 Legal INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR

More information

CCNA DATA CENTER BOOT CAMP: DCICN + DCICT

CCNA DATA CENTER BOOT CAMP: DCICN + DCICT CCNA DATA CENTER BOOT CAMP: DCICN + DCICT COURSE OVERVIEW: In this accelerated course you will be introduced to the three primary technologies that are used in the Cisco data center. You will become familiar

More information

N5 NETWORKING BEST PRACTICES

N5 NETWORKING BEST PRACTICES N5 NETWORKING BEST PRACTICES Table of Contents Nexgen N5 Networking... 2 Overview of Storage Networking Best Practices... 2 Recommended Switch features for an iscsi Network... 2 Setting up the iscsi Network

More information

Configuring Network Load Balancing with Cerberus FTP Server

Configuring Network Load Balancing with Cerberus FTP Server Configuring Network Load Balancing with Cerberus FTP Server May 2016 Version 1.0 1 Introduction Purpose This guide will discuss how to install and configure Network Load Balancing on Windows Server 2012

More information

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESX 4.0 ESXi 4.0 vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until

More information

Backup and Recovery with Cisco UCS Solutions for SAP HANA

Backup and Recovery with Cisco UCS Solutions for SAP HANA Configuration Guide Backup and Recovery with Cisco UCS Solutions for SAP HANA Configuration Guide March, 2014 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page

More information

Romley/Sandy Bridge Server I/O Solutions By Seamus Crehan Crehan Research, Inc. March 2012

Romley/Sandy Bridge Server I/O Solutions By Seamus Crehan Crehan Research, Inc. March 2012 Romley/Sandy Bridge Server I/O Solutions By Seamus Crehan Crehan Research, Inc. March 2012 White Paper sponsored by Broadcom Corporation Impact of Romley/Sandy Bridge Servers: As we discussed in our first

More information

A Dell Technical White Paper Dell PowerConnect Team

A Dell Technical White Paper Dell PowerConnect Team Flow Control and Network Performance A Dell Technical White Paper Dell PowerConnect Team THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES.

More information

Intel Active Management Technology with System Defense Feature Quick Start Guide

Intel Active Management Technology with System Defense Feature Quick Start Guide Intel Active Management Technology with System Defense Feature Quick Start Guide Introduction...3 Basic Functions... 3 System Requirements... 3 Configuring the Client System...4 Intel Management Engine

More information

The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client.

The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client. WatchGuard SSL v3.2 Release Notes Supported Devices SSL 100 and 560 WatchGuard SSL OS Build 355419 Revision Date January 28, 2013 Introduction WatchGuard is pleased to announce the release of WatchGuard

More information

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer

The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer The Future of Computing Cisco Unified Computing System Markus Kunstmann Channels Systems Engineer 2009 Cisco Systems, Inc. All rights reserved. Data Centers Are under Increasing Pressure Collaboration

More information

Abstract. Avaya Solution & Interoperability Test Lab

Abstract. Avaya Solution & Interoperability Test Lab Avaya Solution & Interoperability Test Lab Application Notes for Extreme Networks Summit X450e-24p Switch with Avaya Communication Manager and Avaya IP Telephones in a Converged VoIP and Data Network -

More information

NAC Guest. Lab Exercises

NAC Guest. Lab Exercises NAC Guest Lab Exercises November 25 th, 2008 2 Table of Contents Introduction... 3 Logical Topology... 4 Exercise 1 Verify Initial Connectivity... 6 Exercise 2 Provision Contractor VPN Access... 7 Exercise

More information

Configuring H.323 over Port Network Address Translation (PNAT) for Avaya IP Endpoints using the Avaya SG200 Security Gateway - Issue 1.

Configuring H.323 over Port Network Address Translation (PNAT) for Avaya IP Endpoints using the Avaya SG200 Security Gateway - Issue 1. Configuring H.323 over Port Network Address Translation (PNAT) for Avaya IP Endpoints using the Avaya SG200 Security Gateway - Issue 1.0 Abstract These Application Notes describe how to configure the Avaya

More information

Router Lab Reference Guide

Router Lab Reference Guide Router Lab Reference Guide 1 PURPOSE AND GOALS The routing lab allows testing different IP-related protocols and solutions in a close to live environment. You can learn how to configure Cisco routers and

More information

Best Practice and Deployment of the Network for iscsi, NAS and DAS in the Data Center

Best Practice and Deployment of the Network for iscsi, NAS and DAS in the Data Center Best Practice and Deployment of the Network for iscsi, NAS and DAS in the Data Center Samir Sharma, Juniper Networks Author: Samir Sharma, Juniper Networks SNIA Legal Notice The material contained in this

More information

DCICT: Introducing Cisco Data Center Technologies

DCICT: Introducing Cisco Data Center Technologies DCICT: Introducing Cisco Data Center Technologies Description DCICN and DCICT will introduce the students to the Cisco technologies that are deployed in the Data Center: unified computing, unified fabric,

More information

Our target is an EqualLogic PS100 Storage Array with a portal address of

Our target is an EqualLogic PS100 Storage Array with a portal address of iscsi Multi-Path I/O (MPIO) Example This is a example of how to create an MPIO connection to an iscsi target in a high performance environment. By high performance, we mean that we have an isolated VLAN

More information

Using MLAG in Dell Networks

Using MLAG in Dell Networks dd version Using MLAG in Dell Networks A deployment guide for Dell Networking switches (version ) Dell Engineering March 04 January 04 A Dell Deployment and Configuration Guide Revisions Date Description

More information

Understanding DRAC/MC Alerts

Understanding DRAC/MC Alerts Understanding DRAC/MC Alerts The Dell Remote Access Controller/Modular Chassis (DRAC/MC) provides various alerting mechanisms by which administrators can monitor and manage the components within a Dell

More information

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Version (Kit): 2.5.25-2 Date: August 2011 Purpose and Contact Information These release notes describe the new features,

More information

vrealize Operations Manager Customization and Administration Guide

vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.0.1 This document supports the version of each product listed and supports all subsequent versions until

More information

LotWan Appliance User Guide USER GUIDE

LotWan Appliance User Guide USER GUIDE LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document

More information

HP Virtual Connect FlexFabric Cookbook With HP Virtual Connect Flex-10/10D

HP Virtual Connect FlexFabric Cookbook With HP Virtual Connect Flex-10/10D Technical white paper HP Virtual Connect FlexFabric Cookbook With HP Virtual Connect Flex-10/10D (Version 3.70 through 4.01 Firmware Enhancements) Purpose 4 Documentation feedback 4 Introduction to Virtual

More information

Windows Host Utilities 6.0.2 Installation and Setup Guide

Windows Host Utilities 6.0.2 Installation and Setup Guide Windows Host Utilities 6.0.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277

More information

Software Version 1.0 ConnectKey TM Share to Cloud April 2013. Xerox ConnectKey Share to Cloud User / Administrator s Guide

Software Version 1.0 ConnectKey TM Share to Cloud April 2013. Xerox ConnectKey Share to Cloud User / Administrator s Guide Software Version 1.0 ConnectKey TM Share to Cloud April 2013 Xerox ConnectKey Share to Cloud User / Administrator s Guide 2013 Xerox Corporation. All rights reserved. Xerox, Xerox and Design, and Xerox

More information

Demartek June 2012. Broadcom FCoE/iSCSI and IP Networking Adapter Evaluation. Introduction. Evaluation Environment

Demartek June 2012. Broadcom FCoE/iSCSI and IP Networking Adapter Evaluation. Introduction. Evaluation Environment June 212 FCoE/iSCSI and IP Networking Adapter Evaluation Evaluation report prepared under contract with Corporation Introduction Enterprises are moving towards 1 Gigabit networking infrastructures and

More information

TotalCloud Phone System

TotalCloud Phone System TotalCloud Phone System Cisco SF 302-08P PoE VLAN Configuration Guide Note: The below information and configuration is for deployment of the Cbeyond managed switch solution using the Cisco 302 8 port Power

More information

OneCommand Manager Application for the Drivers for Linux Release Notes

OneCommand Manager Application for the Drivers for Linux Release Notes OneCommand Manager Application for the Drivers for Linux Release Notes Version: 5.2.12.2-1 System: SLES 10 SP3 and SP4 (X86, X64 and PPC) SLES 11 SP1 (X86, X64, IA64 and PPC) RH 5.5(X86, X64, IA64 and

More information

EMC ViPR Controller. User Interface Virtual Data Center Configuration Guide. Version 2.4 302-002-416 REV 01

EMC ViPR Controller. User Interface Virtual Data Center Configuration Guide. Version 2.4 302-002-416 REV 01 EMC ViPR Controller Version 2.4 User Interface Virtual Data Center Configuration Guide 302-002-416 REV 01 Copyright 2014-2015 EMC Corporation. All rights reserved. Published in USA. Published November,

More information

Efficient Video Distribution Networks with.multicast: IGMP Querier and PIM-DM

Efficient Video Distribution Networks with.multicast: IGMP Querier and PIM-DM Efficient Video Distribution Networks with.multicast: IGMP Querier and PIM-DM A Dell technical white paper Version 1.1 Victor Teeter Network Solutions Engineer This document is for informational purposes

More information

Windows Host Utilities 6.0 Installation and Setup Guide

Windows Host Utilities 6.0 Installation and Setup Guide Windows Host Utilities 6.0 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP

More information

ALCATEL-LUCENT ENTERPRISE AND QLOGIC PRESENT

ALCATEL-LUCENT ENTERPRISE AND QLOGIC PRESENT ALCATEL-LUCENT ENTERPRISE AND QLOGIC PRESENT A VIRTUALIZED AND CONVERGED NETWORK FOR ENTERPRISE DATACENTERS APPLICATION NOTE TABLE OF CONTENTS Introduction / 1 The case for Ethernet / 2 The components

More information

Data Center Fabric Convergence for Cloud Computing (the Debate of Ethernet vs. Fibre Channel is Over)

Data Center Fabric Convergence for Cloud Computing (the Debate of Ethernet vs. Fibre Channel is Over) Extreme Networks White Paper Data Center Fabric Convergence for Cloud Computing (the Debate of Ethernet vs. Fibre Channel is Over) The evolution of the data center fabric has been well documented. The

More information

AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes

AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch. Software Release Notes AT-S60 Version 1.1.4 Management Software for the AT-8400 Series Switch Supported Platforms Software Release Notes Please read this document before you begin to use the AT-S60 management software. The AT-S60

More information

Configure Backup Server for Cisco Unified Communications Manager

Configure Backup Server for Cisco Unified Communications Manager Configure Backup Server for Cisco Unified Communications Manager Document ID: 110309 Contents Introduction Prerequisites Requirements Components Used Conventions Configure a Backup Server for Cisco Unified

More information

Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2

Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2 Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2 Dell Engineering Donald Williams November 2013 A Dell Deployment and Configuration Guide Revisions Date November 2013 Description Initial

More information

Switch Quick Configuration CLI Guide for

Switch Quick Configuration CLI Guide for Switch Quick Configuration CLI Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S SSE-X3348SR SSE-X3348T SSE-X3348TR SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release : 1.0d 1 /

More information

Frequently Asked Questions: EMC UnityVSA

Frequently Asked Questions: EMC UnityVSA Frequently Asked Questions: EMC UnityVSA 302-002-570 REV 01 Version 4.0 Overview... 3 What is UnityVSA?... 3 What are the specifications for UnityVSA?... 3 How do UnityVSA specifications compare to the

More information

Data Center Bridging Plugfest

Data Center Bridging Plugfest Data Center Bridging Plugfest Version 1.0, August 2009 Contributors: Eddie Tan, Cisco Gary Gumanow, Dell Kirt Gillum, Dell Joy Jiang, Finisar Dan Daly, Fulcrum Microsystems Shawn Dutton, NetApp Manoj Wadekar,

More information

ProSafe Plus Switch Utility

ProSafe Plus Switch Utility ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA December 2012 202-10524-05 NETGEAR, Inc. All rights reserved No part of this publication maybe reproduced, transmitted,

More information

WHITE PAPER. Best Practices in Deploying Converged Data Centers

WHITE PAPER. Best Practices in Deploying Converged Data Centers WHITE PAPER Best Practices in Deploying Converged Data Centers www.ixiacom.com 915-2505-01 Rev C October 2013 2 Contents Introduction... 4 Converged Data Center... 4 Deployment Best Practices... 6 Testing

More information

BASCS in a Nutshell Study Guide for Exam 160-020 Brocade University Revision 03-2012

BASCS in a Nutshell Study Guide for Exam 160-020 Brocade University Revision 03-2012 BASCS in a Nutshell Study Guide for Exam 160-020 Brocade University Revision 03-2012 2013 Brocade Communications Corporate Headquarters - San Jose, CA USA T: (408) 333-8000 info@brocade.com European Headquarters

More information