Beacons and indicator banks Ø 70 optimum Harmony XVE. Catalogue March

Size: px
Start display at page:

Download "Beacons and indicator banks Ø 70 optimum Harmony XVE. Catalogue March"

Transcription

1 Beacons and indicator banks Ø 70 optimum Harmony XVE Catalogue March 04

2

3 Contents Beacons and indicator banks b Presentation page b Description page b Characteristics page 4 b References pages 5 to 7 b Dimensions, mounting, connection pages 8 and 9

4 Presentation Beacons and indicator banks 0 Presentation The beacons and indicator banks of the XVE range are designed for remote signalling of the status of a machine, equipment or specific application, either visually using illuminated units which are visible throughout 60 or audibly using an 85 db buzzer. The XVE Optimum range provides efficient signalling (5 colours available), at medium range distances (0 m), in both indoor and outdoor environments. The standard configuration of the beacons and indicator banks is an IP 4 degree of protection, which is sufficient for the majority of indoor applications. Both the IP 4 pre-configured beacons and indicator banks can be upgraded to IP 54 by using a sealing kit (). Depending on the indicator bank base unit selected, it is possible to achieve an IP 54 degree of protection for outdoor usage (). Composition b The beacons are supplied complete and incorporate a single steady or flash light illuminated unit and a short fixing base. They are ready to use. b The indicator banks must be assembled by the user and comprise signalling units, mounted on a base unit, and a fixing base. These various items are to be selected from the catalogue. v For an indicator bank a maximum of 5 illuminated units or 4 illuminated units + audible unit can be assembled. v The illuminated or audible units stack vertically and are easily fitted together. A screw secures their mounting. Electrical connections between each unit are made automatically as the units are mechanically assembled. v All the signalling units are identical in size and their positioning is unrestricted. Signalling functions Steady light signalling Two types of light source are available for steady light signalling: v The incandescent BA 5d base fitting bulb, 5 W max. power, is recommended for infrequent usage and where no vibration or mechanical shock exists. The bulb is not included with the lens unit and must be fitted separately. v LEDs are recommended for continuous usage: 00,000 operating hours without maintenance and low consumption. They have a good resistance to vibration. Using an LED of a colour best suited to the colour of the lens unit provides optimal luminosity. Flashing light signalling Flashing light signalling is also obtained using the LED. It meets requirements regarding reliability, continuous usage and electronic simplicity. A flashing function can also be obtained from a steady light LED illuminated unit by using a PLC output signal. Flash light signalling The light source is a Joule discharge tube which delivers a powerful warning signal. It is available for the 5 colours. Audible signalling Audible signalling is provided by a continuous tone buzzer with a power rating of 85 db at m. Installation Mounting Fixed onto support panel using plastic monobloc fixing base or fixing base comprising an aluminium support tube pre-fitted into a plastic fixing support. Cabling Cabling by means of terminal block incorporated in base unit. The terminals are protected and of the screw and captive cable clamp type. () See page 7. Characteristics: page 4 References: pages 5 to 7 Dimensions: pages 8 and 9

5 Description Beacons and indicator banks Description Illuminated beacon The illuminated beacon is a complete product comprising: A screw fixing cover. One coloured illuminated unit (green, red, orange, blue or clear). A base unit with terminal block and bottom cable entry. 4 A monobloc fixing base for mounting on machine. Indicator bank The indicator bank is a customer assembled product using: 5 A cover. 6 to 5 coloured illuminated units (green, red, orange, blue or clear) with a choice of types of signalling (steady, flashing or flash ). 7 audible unit. 8 A base unit (IP 4 or IP 54) with terminal block and bottom cable entry. 9 A plastic fixing base, 0 mm high. 0 A plastic fixing base, 00 mm high. An aluminium support tube, black or natural finish, length: 00, 400 or 800 mm, pre-fitted and glued into a fixing base. To be ordered separately: Fixing plate for mounting on vertical support

6 Characteristics Beacons and indicator banks 0 Environment Degree of protection Conforming to IEC 6059 b IP 4 in vertical position, IP 40 for other positions b IP 54 for reinforced protection version: v for all mounting positions using fixing base XVE Z, v only in vertical position for other heights of fixing base Product certifications e, UL, CSA Approvals CCC (pending) Conformity to standards IEC/EN , IEC/EN Ambient air temperature For storage C For operation C Electric shock protection Conforming to IEC 640 Protective treatment Mounted on plastic support tube Mounted on aluminium support tube Class l Class l Standard version: "TC" Electronic components protection (LED and flash) Electrical characteristics Illuminated units By integral fuse in series on the common A 0.6 (z 4 V) A 0.6 (a 0 40 V) With bulb, not included (lens unit only) With integral LED, steady light With integral LED, flashing light Rated insulation voltage (Ui) Conforming to IEC V With flash discharge tube, Joule Voltage limits Conforming to IEC V Un (Un: nominal voltage) Light source BA 5d base fitting bulb, maximum power 5 W (40 V max.) Consumption On z 4 V ma Depending on bulb used On z 0 V ma Depending on bulb used On a 0/40 V ma Depending on bulb used Rated impulse withstand Conforming to IEC kv U imp = 4 voltage Illuminating power Average value for all colours cds/ m² LED LED Flash discharge tube, Joule on a 4 V 76 on c 4 V Flashing frequency Nominal value Hz Audible units Consumption On z 4 V ma On z 0 V ma 0 On a 0/40 V ma 0 Power Continuous tone db 85 at m Fundamental frequency khz.8 for continuous tone Connection of illuminated and audible units Terminal referencing Connection Maximum clamping capacity on protected, ready-to-tighten, screw and captive cable clamp terminals mm terminal referenced C common to all 5 units 5 terminals referenced to 5 x.5 with cable end Presentation: pages and References: pages 5 to 7 Dimensions: pages 8 and 9 4

7 References Beacons and indicator banks 0 Illuminated beacons Illuminated beacons with steady light Description Light source Supply voltage Complete unit Bulb, not comprising: included, - screw fixing cover, 5 W max. - illuminated unit, - base unit, - short fixing base Colour of lens unit Reference Weight z 40 V max. Green XVE L 0.45 Red XVE L Orange XVE L Blue XVE L Clear XVE L XVE Lpp Illuminated unit with integral LED z 4 V Green XVE LB 0.50 Red XVE LB Orange XVE LB Blue XVE LB Clear XVE LB XVE Lpp a 0 V Green XVE LG 0.50 Red XVE LG Orange XVE LG Blue XVE LG Clear XVE LG a 0 V/40 V Green XVE LM 0.50 Red XVE LM Orange XVE LM Blue XVE LM Clear XVE LM Illuminated beacons with flash light Description Light source Supply voltage Complete unit Illuminated comprising: unit with - screw fixing cover, Joule flash - illuminated unit, discharge tube - base unit, - short fixing base Colour of lens unit Reference Weight z 4 V Green XVE L6B 0.70 Red XVE L6B Orange XVE L6B Blue XVE L6B Clear XVE L6B XVE L6pp a 0 V Green XVE L6G 0.70 Red XVE L6G Orange XVE L6G Blue XVE L6G Clear XVE L6G a 0 V/40 V Green XVE L6M 0.70 Red XVE L6M Orange XVE L6M Blue XVE L6M Clear XVE L6M XVE Z08 Separate components Description Details Reference Weight IP 54 sealing kit Fixing plate lens unit seal + base unit seal + fixing base seals For mounting beacons on vertical support (requires a fixing base) XVE Z XVB C 0.80 XVB C Description Electrical characteristics Sold in lots of Reference Weight DL BEpS Clear incandescent bulbs with BA 5d base fitting for lens units type XVE Lp 5 W z 4 V 5 W z 0 V 5 W z 0 V 0 DL BEBS DL BEGS DL BEMS

8 References Beacons and indicator banks 0 Indicator banks for customer assembly Composition of an indicator bank: XVE Cp Illuminated units with steady light Description Light source Supply voltage Lens units only Bulb, not included, for BA 5d base 5 W max. fitting bulb Colour of lens Reference Weight z 40 V max. Green XVE C 0.07 Red XVE C Orange XVE C Blue XVE C Clear XVE C Cover and base unit + Illuminated or audible units (5 units max.) + Fixing base XVE Cpp Illuminated units Integral LED z 4 V Green XVE CB Red XVE CB Orange XVE CB Blue XVE CB Clear XVE CB a 0 V Green XVE CG Red XVE CG Orange XVE CG Blue XVE CG Clear XVE CG a 0 V/40 V Green XVE CM Red XVE CM Orange XVE CM Blue XVE CM Clear XVE CM XVE C5pp XVE C6pp XVE C9p Illuminated units with flashing light Illuminated units Integral LED z 4 V Green XVE C5B Red XVE C5B Orange XVE C5B Blue XVE C5B Clear XVE C5B a 0 V Green XVE C5G Red XVE C5G Orange XVE C5G Blue XVE C5G Clear XVE C5G a 0 V/40 V Green XVE C5M Red XVE C5M Orange XVE C5M Blue XVE C5M Clear XVE C5M Illuminated units with flash light Illuminated units Audible units Flash discharge tube, Joule z 4 V Green XVE C6B Red XVE C6B Orange XVE C6B Blue XVE C6B Clear XVE C6B a 0 V Green XVE C6G Red XVE C6G Orange XVE C6G Blue XVE C6G Clear XVE C6G a 0 V/40 V Green XVE C6M Red XVE C6M Orange XVE C6M Blue XVE C6M Clear XVE C6M Description Power Supply voltage Reference Weight Buzzer single tone 85 db at metre z 4 V XVE C9B a 0 V XVE C9G a 0 V/40 V XVE C9M Presentation: pages and 6 Characteristics: page 4 Dimensions: page 9

9 References (continued) Beacons and indicator banks 0 Indicator banks for customer assembly Base units and covers Indicator bank usage Composition Reference Weight Indoors (IP 4) Base unit and cover XVE C 0.0 XVE C Outdoors (IP 54) Base unit with seal + screw fixing cover + kit comprising 5 seals for lens units and buzzer + seal for fixing base XVE Z XVE CP 0.0 XVB CP Fixing components Description Height under base unit (mm) Colour Reference Weight Plastic fixing bases 0 Black XVE Z Black XVD C XVE Z XVD C0 Fixing bases comprising: Ø 5 mm aluminium support tube + black plastic fixing support 80 Black aluminium XVB Z0 0.0 Aluminium XVB Z0A Black aluminium XVB Z Aluminium XVB Z0A Black aluminium XVB Z XVB Z0 XVB Z0 Aluminium XVB Z04A 0.5 Description For Material Reference Weight Fixing base Ø 5 mm aluminium support tube Plastic XVB Z XVB Z0 XVB C Fixing plate Mounting indicator banks on vertical support (requires a fixing base) Zamak XVB C 0.80 Separate components Description Composition Reference Weight Cover XVE Z XVE Z08 XVE Z08 DL BEpS IP 54 sealing kit Description Clear incandescent bulbs with BA 5d base fitting for lens units type XVE Cp 5 toric seals for lens units + base unit seal + fixing base seal + seal for fixing base XVE Z + screw fixing cover Electrical characteristics 5 W z 4 V 5 W z 0 V 5 W z 0 V Sold in lots of XVE Z Reference Weight 0 DL BEBS DL BEGS DL BEMS

10 Dimensions, mounting, connection Beacons and indicator banks 0 Illuminated beacons Illuminated beacons XVE Lppp Panel cut-out for mounting directly on fixing base 9 Ø70 Ø7 4xØ5,5 Ø xØ5,5 54 Mounting on fixing plate XVB C Vertical support panel drillings for mounting fixing plate XVB C Wiring scheme xø5 or M5 C 5 4 5,5 5,5 4,5 4 = = Presentation: pages and 8 Characteristics: page 4 References: pages 5 to 7

11 Dimensions, mounting, connection Beacons and indicator banks 0 Indicator banks Indicator banks XVE Cppp b Cover XVE Z08 or cover XVE C/CP (with base unit), Illuminated units XVE Cpp and/or audible unit XVE C9p, Base unit XVE C/CP, 4 Fixing bases (see below). Height of indicator bank Number of units (ref. ) b unit units 6 units 5 4 units 67 5 units 9 Fixing bases (height under base unit) XVE Z XVD C0 XVB Z0pp Panel cut-out for mounting directly on fixing base b Ø7 4xØ5, Ø70 Ø70 Ø70 Height under base unit Fixing base b XVB Z0/Z0A 80 XVB Z0/Z0A 400 XVB Z04/Z04A Mounting on fixing plate XVB C Vertical support panel drillings for mounting fixing plate XVB C Wiring scheme 5 4 xø5 or M5 C 5,5 5,5 4, = =

12 Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F Rueil Malmaison Cedex Owing to changes in standards and equipment, the characteristics given in the text and images in this document are not binding until they have been confirmed with us. Production : Schneider Electric Industries Photos : Schneider Electric Industries Printed by : DIA4ED040407EN ART Mars 004

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Signal Tower modulsignal50

Signal Tower modulsignal50 Signal Tower modulsignal50 S I G N A L G E R Ä T E modulary construction with bayonet locking system fast and easy to operate, mount, configurate and change of modules troublefree and fingersafe bulb change

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

PROXIMITY CARD READERS C-10, C-20, C60, C70

PROXIMITY CARD READERS C-10, C-20, C60, C70 Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5 - TFT - 96 MB Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light

More information

know-how Giant in distributing electricity for industry Prisma GK

know-how Giant in distributing electricity for industry Prisma GK Prisma GK Giant know-how in distributing electricity for industry Installation system up to 630A for electrical power distribution and circuit control. Prisma GK: technology and innovation for an IP55

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Signal Tower modulsignal70

Signal Tower modulsignal70 Signal Toer modulsignal7 S I G N A L G E R Ä T E modulary construction ith bayonet locking system fast and easy to operate, mount, configurate and change of modules troublefree and fingersafe bulb change

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

SMART Board interactive flat panel with appliance Model 8055ie-SMP

SMART Board interactive flat panel with appliance Model 8055ie-SMP Specifications SMART Board interactive flat panel with appliance Model 8055ie-SMP Physical specifications Size 52 3/8" W 32 5/16" H 3 11/16" D (133 cm 82 cm 9.3 cm) (See Physical dimensions on page 7 for

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

P System Cubicles. Certified for more safety

P System Cubicles. Certified for more safety P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

DuroSite TM High Bay Lighting

DuroSite TM High Bay Lighting DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic

More information

EPIC CIRCON M23 Series Circular Signal Connectors

EPIC CIRCON M23 Series Circular Signal Connectors Circular Signal Connectors CIRCON M2 circular signal connectors are designed to DIN specification N698 and have a standard M2 threaded connection housing. They are offered in coupler, connector, and panel

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150 Page 162 NEW Page 154 Page 158 Page 146 Page 157 Page 152 Page 160 Page 159 Page 149 Page 156 Page 150 Summary Audible Signal Devices Page 151 Page 163 Page 148 installation version Free-standing Electronic

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V APC Smart-UPS, 670 Watts / 1000 VA,Input 230V / Output 230V, Interface Port DB-9 RS-232, SmartSlot, USB Includes: CD with software, Smart UPS signalling

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

nano led THE GREEN LIGHT

nano led THE GREEN LIGHT nano led THE GREEN LIGHT nano led CHARACTERISTICS - LUMINAIRE Luminaire tightness level: IP 66 (*) Impact resistance: IK 08 (**) Nominal voltage: 230 V - 50 Hz Electrical class: II (*) Weight (empty):

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING

DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING LOW ENERGY LIGHTING LAMPS 185 LED Fixed Fixed Colour Flexi Colour

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

ZMR 80 STEREO MODULAR ZONER USERS MANUAL ZMR 80 STEREO MODULAR ZONER USERS MANUAL Lime Technologies http://limetechnologies.co.uk Tel: 08712 233127 ZMR80 Stereo Modular Zoner Mixer Introduction The modular construction of the ZMR80 allows it

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice

More information

General 1-2-Opto-electronics Safety Switches 4-Emergency

General 1-2-Opto-electronics Safety Switches 4-Emergency General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

CELO5. User & Installation Manual. www.audac.eu

CELO5. User & Installation Manual. www.audac.eu CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt

More information

GV- RK1352 Card Reader

GV- RK1352 Card Reader GV- RK1352 Card Reader The GV-RK1352 is a card reader with keypad, designed to recognize PIN codes, identification cards or both. Featured with the Wiegand and RS-485 outputs, the unit can be connected

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information