SLC 500 Analog Input Modules
|
|
- Mervyn Hodge
- 7 years ago
- Views:
Transcription
1 Installation Instructions SLC 500 Analog Input Modules (Catalog Numbers 1746NI16I and 1746NI16V) Inside Important User Information... 2 For More Information...3 Hazardous Location Considerations... 4 Environnements dangereux... 4 Electrostatic Damage NI16 Power Requirements... 5 Module Location in Chassis... 6 Heat and Noise Considerations... 6 Module Installation and Removal... 7 Terminal Wiring... 9 Input Devices Transducer Source Impedance Specifications... 15
2 2 SLC 500 Analog Input Modules Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, AllenBradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. AllenBradley publication SGI1.1, Safety Guidelines for the Application, Installation and Maintenance of SolidState Control (available from your local AllenBradley office), describes some important differences between solidstate equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication. Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited. ATTENTION! Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attention statements help you to: identify a hazard avoid the hazard recognize the consequences IMPORTANT Identifies information that is critical for successful application and understanding of the product.
3 SLC 500 Analog Input Modules 3 For More Information For detailed information on planning and installing your system, see the following publications: Publication Publication Number Industrial Automation Wiring and Grounding Guidelines SLC 500 Analog Input Modules User Manual 1746UM001AUSP SLC 500 Modular Hardware Style Operation and Installation Manual SLC 500 Fixed Hardware Style Operation and Installation Manual If you would like a manual, you can: download a free electronic version from the internet: purchase a printed manual by: contacting your local distributor or Rockwell Automation representative visiting and placing your order calling (USA/Canada) or (Outside USA/Canada)
4 4 SLC 500 Analog Input Modules Hazardous Location Considerations This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or nonhazardous locations only. The following ATTENTION statement applies to use in hazardous locations. WARNING! EXPLOSION HAZARD Substitution of components may impair suitability for Class I, Division 2. Do not replace components or disconnect equipment unless power has been switched off. Do not connect or disconnect components unless power has been switched off. This product must be installed in an enclosure. Environnements dangereux Cet équipement est conçu pour être utilisé dans des environnements de Classe 1, Division 2, Groupes A, B, C, D ou non dangereux. La mise en garde suivante s applique à une utilisation dans des environnements dangereux. MISE EN GARDE! DANGER D EXPLOSION La substitution de composants peut rendre cet équipement impropre à une utilisation en environnement de Classe 1, Division 2. Ne pas remplacer de composants ou déconnecter l'équipement sans s'être assuré que l'alimentation est coupée. Ne pas connecter ou déconnecter des composants sans s'être assuré que l'alimentation est coupée. Ce produit doit être installé dans une armoire.
5 SLC 500 Analog Input Modules 5 Electrostatic Damage Electrostatic discharge can damage semiconductor devices inside this module if you touch backplane connector pins. Guard against electrostatic damage by observing the following precautions. ATTENTION! Electrostatic discharge can degrade performance or cause permanent damage. Handle the module as stated below. Wear an approved wrist strap grounding device when handling the module. Touch a grounded object to rid yourself of electrostatic charge before handling the module. Handle the module from the front, away from the backplane connector. Do not touch backplane connector pins. Keep the module in its staticshield bag when not in use, or during shipment. 1746NI16 Power Requirements The 1746NI16 module receives its power through the SLC 500 chassis backplane from the fixed or modular 5V dc/24v dc chassis power supply. The 5V dc backplane supply powers the SLC circuitry and the 24V dc backplane supply powers the module analog circuitry. The maximum current drawn by the module is shown in the table below. 5V dc Amps 24V dc Amps 125 ma 75 ma When you are using a modular system configuration, add the values shown in the table above to the requirements of all other modules in the SLC chassis to prevent overloading the chassis power supply.
6 6 SLC 500 Analog Input Modules Module Location in Chassis Modular Chassis Considerations Place your 1746NI16 module in any slot of an SLC 500 modular, or modular expansion chassis, except for the extreme left slot (slot 0) in the first chassis. This slot is reserved for the processor or adapter modules. Operating Temperature Range 0 C to 60 C (32 F to 140 F) Fixed Expansion Chassis Considerations IMPORTANT The 2slot, SLC 500 fixed I/O expansion chassis (1746A2) supports only specific combinations of modules. If you are using the 1746NI16 module in a 2slot expansion chassis with another SLC I/O or communication module, refer to the 1746NI16 user manual to determine whether the combination can be supported. Heat and Noise Considerations Most applications require installation in an industrial enclosure to reduce the effects of electrical interference. Analog inputs are highly susceptible to electrical noise. Electrical noise coupled to the analog inputs reduces the performance (accuracy) of the module. Group your modules to minimize adverse effects from radiated electrical noise and heat. Consider the following conditions when selecting a slot for the analog input module. Position the module: in a slot away from sources of electrical noise such as hardcontact switches, relays, and AC motor drives away from modules which generate significant radiated heat, such as the 32point I/O module (series C or earlier) In addition, route shielded twisted7pair analog input wiring away from any highvoltage I/O wiring.
7 SLC 500 Analog Input Modules 7 Module Installation and Removal When installing the module in a chassis, it is not necessary to remove the terminal block from the module. However, if the terminal block is removed, use the writeon label (shown below) located on the side of the terminal block to identify the module location and type. SLOT MODULE RACK ATTENTION! Remove power before removing or inserting this module. When you remove or insert a module with power applied, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: sending an erroneous signal to your system s field devices, causing unintended machine motion causing an explosion in a hazardous environment Electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance. Terminal Block Removal 1. Loosen the two terminal block release screws. Terminal Block Release Screws 2. Grasp the terminal block at the top and bottom and pull outward and down.
8 8 SLC 500 Analog Input Modules Module Installation Procedure 1. Align the circuit board of the analog input module with the card guides located at the top and bottom of the chassis. 2. Slide the module into the chassis until both top and bottom retaining clips are secured. Apply firm even pressure on the module to attach it to its backplane connector. Never force the module into the slot. 3. Cover all unused slots with the Card Slot Filler, Catalog Number 1746N2. Top and Bottom Module Release(s) Card Guide Module Removal Procedure 1. Press the releases at the top and bottom of the module and slide the module out of the chassis slot. 2. Cover all unused slots with the Card Slot Filler, Catalog Number 1746N2.
9 SLC 500 Analog Input Modules 9 Terminal Wiring The 1746NI16 module contains an 18position, removable terminal block. The terminal pinout is shown below. ATTENTION! Disconnect power to the SLC before attempting to install, remove, or wire the removable terminal wiring block. To avoid cracking the removable terminal block, alternate the removal of the slotted terminal block release screws. Terminal Block (Terminal Block Spare Part Catalog Number 1746RT25G) Channel 0 Channel 2 Channel 4 Channel 6 Analog Com Channel 8 Channel 10 Channel 12 Channel 14 Channel 1 Channel 3 Channel 5 Channel 7 Analog Com Channel 9 Channel 11 Channel 13 Channel 15 Terminal Block Release Screw Maximum Torque = 0.7 to 0.9 Nm (6 to 8 inlbs.) Prewired Cables and Terminal Blocks The following 1492 cables and terminal blocks are available to assist in wiring the 1746NI16 module: AllenBradley Prewired Cables AllenBradley User Terminal Blocks 1492ACAB005A46, 0.5m (1.6 ft. 1492ACAB010A46, 1.0 m (3.3 ft.) 1492ACAB025A46, 2.5 m (8.2 ft.) 1492ACAB050A46, 5.0 m (16.4 ft.) 1492AIFM AIFM16F3
10 10 SLC 500 Analog Input Modules Wiring SingleEnded Inputs The diagram below shows typical wiring for the 1746NI16V module. Channel 0 Voltage Transmitter Channel 2 Voltage Transmitter Channel 4 Voltage Transmitter Channel 6 Voltage Transmitter Vdc power supply (5) (2) (2) (2) (2) (1) IN0 IN2 IN4 IN6 Analog Com IN8 IN1 IN3 IN5 IN7 Analog Com IN9 (1) (3) Optional second Vdc power supply (6) IN10 IN12 IN11 IN13 (3) (3) (4) IN14 IN15 (3) (1) There are two common terminals for all of the 16 voltage inputs. These two analog common terminals are connected internally. (2) All shield wires should be connected to chassis mounting screws. (3) Unused channels should be connected to the analog common terminals (0 Volts). (4) If separate shielded cables are used for each analog input channel, interposing terminal blocks are needed to terminate up to 16 common wires. Then 1 to 4 common wires should be wired from the interposing terminal block to the 2 common terminals on the 1746NI16V module. (5) The module does not provide loop power for analog inputs. Use a power supply that matches the transmitter specifications. (6) More than one power supply can be used if all supplies are class 2. NOTE Although the above diagram has 12 unused inputs, only 4 channels are shown connected to the Analog Com as an example.
11 SLC 500 Analog Input Modules 11 Wiring SingleEnded Inputs The diagram below shows typical wiring for the 1746NI16I module. Channel 0 2wire current Transmitter Channel 2 2wire current Transmitter Channel 4 2wire current Transmitter Channel 6 3wire current Transmitter Vdc power supply (5) (2) (2) (2) (2) IN0 IN1 IN2 IN3 IN4 IN5 IN6 IN7 Analog Analog Com Com (1) (1) IN8 IN9 (3) Optional second Vdc power supply (6) IN10 IN12 IN11 IN13 (3) (3) (1) There are two common terminals for all of the 16 current inputs. These two analog common terminals are connected internally. (2 All shield wires should be connected to chassis mounting screws. (3) Unused channels should be connected to the analog common terminals (0 Volts). (4) If separate shielded cables are used for each analog input channel, interposing terminal blocks are needed to terminate up to 16 common wires. Then 1 to 4 common wires should be wired from the interposing terminal block to the 2 common terminals on the 1746NI16I module. (5) The module does not provide loop power for analog inputs. Use a power supply that matches the transmitter specifications. (6) More than one power supply can be used if all supplies are class 2. IN14 IN15 NOTE Although the above diagram has 12 unused inputs, only 4 channels are shown connected to the Analog Com as an example. (4) (3)
12 12 SLC 500 Analog Input Modules Wiring Guidelines ATTENTION! To prevent shock hazard, care should be taken when wiring the module to analog signal sources. Before wiring any analog module, disconnect power from the SLC 500 system and from any other source to the analog module. Follow the guidelines below when planning your system wiring. To limit noise, keep signal wires as far away as possible from power and load lines. To ensure proper operation and high immunity to electrical noise, always use Belden 8761 (shielded, twisted pair) or equivalent wire. Connect the shield drain wire to the earth ground of the chassis. Tighten terminal screws using a standard or crosshead screwdriver. Each screw should be turned tight enough to immobilize the wire s end. Excessive tightening can strip the terminal screw. The torque applied to each screw should not exceed 0.7 to 0.9 Nm (6 to 8 inlb) for each terminal. Follow system grounding and wiring guidelines found in your SLC 500 Modular Hardware Style Installation and Operation Manual, publication
13 SLC 500 Analog Input Modules 13 Input Devices Transducer Source Impedance If the source impedance of the input device and associated cabling is too high, it will affect the accuracy of the channel data word. Source impedance of 2000 ohms will produce up to 0.01% of module error over and above the specified accuracy of the module. You can compensate for device impedance error by implementing the following equation in your ladder program: V S V measured (R s R in ) R in where: Vs = input device voltage Rs = input device impedance Rin = 1746NI16 input impedance (See Specifications on page 17)
14 14 SLC 500 Analog Input Modules Wiring Input Devices to the 1746NI16 After the analog input module is properly installed in the chassis, follow the wiring procedure below using Belden 8761 cable. ATTENTION! Care should be taken to avoid connecting a voltage source to a current input module. Improper module operation or damage to the voltage source can occur. Cable Signal Wire (Cut foil shield and drain wire.) Foil Shield Drain Wire Signal Wire (Twist the drain wire and the foil shield together and connect to earth ground or to the chassis mounting screws.) To wire your 1746NI16 module follow these steps. 1. At each end of the cable, strip some casing to expose the individual wires. 2. Trim the signal wires to 50 mm (2 inch) lengths. Strip about 5 mm (3/16 inch) of insulation away to expose the end of the wire. 3. At one end of the cable, twist the drain wire and foil shield together. 4. At the other end of the cable, cut the drain wire and foil shield back to the cable. 5. Connect the signal wires to the 1746NI16 terminal block or interposing terminal block. 6. Connect the shield drain wire to chassis ground. 7. Connect the other end of the cable to the voltage or current transmitter terminals. 8. Repeat steps 1 through 7 for each channel on the module.
15 SLC 500 Analog Input Modules 15 Specifications Electrical Specifications Description Specification Backplane Current Consumption 125 ma at 5V dc 75 ma at 24V dc Backplane Power Consumption 2.425W maximum (0.625W at 5V dc, 1.8W at 24V dc) Number of Channels 16 (backplane isolated) I/O Chassis Location Any I/O module slot except slot 0 A/D Conversion Method Sigma Delta Input Filtering Lowpass digital filter with programmable filter frequencies Normal Mode Rejection (between [] input and [ ] input) Common Mode Rejection (between inputs and chassis ground) Input Filter Frequencies Isolation CommonMode Voltage Range >80 db at 50/60 Hz >75 db at dc >100 db at 50/60 Hz Greater than or equal to 75 db at DC Greater than or equal to 100 db at 50/60 Hz 6 Hz, 10 Hz, 20 Hz, 40 Hz, 60 Hz, 80 Hz, 100 Hz, 250 Hz 500V ac isolation for 1 second ±10.25V relative to analog common terminal (20.5V maximum between any two signal input terminals)
16 16 SLC 500 Analog Input Modules Physical Specifications Description Specification LED Indicators 5 green status indicators one for each group of 4 channels and one for module status Module ID Code Class 1 Class 3 NI16V NI16I Recommended Cable Belden #8761 or equivalent Maximum Wire Size Two 14 AWG wires per terminal Maximum Cable Impedance Terminal Block AllenBradley Prewired Cables NI16V NI16I AllenBradley User Terminal Blocks Voltage Source (with less than 10Ω impedance): 1250Ω maximum loop impedance, for <1LSB error Current Source (transmitter properly wired to its power supply): 249Ω maximum loop impedance, to meet commonmode voltage requirements Removable, AllenBradley spare part Catalog Number 1746RT25G 1492ACAB005A46, 0.5m (1.6 ft.) 1492ACAB010A46, 1.0 m (3.3 ft.) 1492ACAB025A46, 2.5 m (8.2 ft.) 1492ACAB050A46, 5.0 m (16.4 ft.) 1492AIFM AIFM16F3 Environmental Specifications Description Operating Temperature Storage Temperature Relative Humidity Agency Certification Hazardous Environment Classification Specification 0 C to 60 C (32 F to 140 F) 40 C to 85 C (40 F to 185 F) 5% to 95% (without condensation) UL listed CUL approved CE compliant for all applicable directives Class I Division 2 Hazardous Environment Groups A, B, C, D
17 SLC 500 Analog Input Modules 17 Input Specifications Description Specification Type of Input (Selectable) NI16V ±10V dc, 1 to 5V, 0 to 5V, or 0 to 10V NI16I ±20 ma, 4 to 20 ma, 0 to 1 ma, 0 to 20 ma Type of Data (Selectable) Engineering Units (1 mv/step or 1 µa/step) ScaledforPID (0 to 16,383 range) Proportional Counts (32,768 to 32,767 range) Proportional Counts (User Defined Range, Class 3 only) 1746NI4 Data Format Input Impedance NI16V 20 MΩ NI16I 249 Ω Maximum Voltage Input NI16V ±30V between any two signal terminals without damage Maximum Voltage Input NI16I ±8V between any two signal terminals without damage Current Input (maximum) ±30 ma (Between analog com and any input terminal) Time to Detect Open Circuit Less Than 5 seconds Module Update Time (1) Input Resolution NI16V 312 µv (2) NI16I 640 na Display Resolution 1 mv or 1 µa Module Error Over Full NI16V Temperature Range (0 C to 60 C, 32 F to 140 F) NI16I Voltage input types (±10V dc, 1 to 5V dc, 0 to 5V dc, 0 to 10V dc): ±0.1% Current input types (0 to 20 ma, 4 to 20 ma, 0 to 1mA, ±20 ma): ±0.3% Input Offset Drift with NI16V 90 µv/ C Temperature NI16I 360 na/ C Gain Drift with Temperature NI16V 15 ppm/ C NI16I 20 ppm/ C Calibrated Accuracy at 25 C NI16V Better than 0.05% of range NI16I Better than 0.15% of range (1) Depends on filter selected. Refer to the 1746NI16 User Manual, publication 1746UM001AUSP. (2) Depends on data mode: Engineering Units or Proportional Counts.
18 18 SLC 500 Analog Input Modules Notes:
19 SLC 500 Analog Input Modules 19
20 SLC 500 is a trademark of Rockwell Automation. Belden is a trademark of Belden, Inc. December 1999 Supersedes Publication 1746IN001AUSP September 1999 PN (C) 2006 Rockwell Automation, Inc. Printed in Singapore.
SLC 500 Analog Input Module
Installation Instructions SLC 500 Analog Input Module (Catalog Number 1746NI8) Inside Important User Information... 2 For More Information... 3 Hazardous Location Considerations... 4 Environnements dangereux...
More informationBackup Scanner Module
Backup Scanner Module Catalog Number 1747-BSN Installation Instructions 2 Backup Scanner Module Important User Information Because of the variety of uses for the products described in this publication,
More informationAllen-Bradley/Rockwell
MANUFACTURER DATA SHEET Analog I/O Module Manufacturer: Allen-Bradley/Rockwell Model Number: 1746-NI4 See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014624-18 VendorPartNumber:
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationHard Disk Drive (HDD)
Installation Instructions Hard Disk Drive (HDD) Catalog Number 6189V-35HDDST80, 6189V-35HDDST160 Topic Page About This Publication 1 Important User Information 2 Electrostatic Discharge (ESD) Precautions
More informationIsolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
More informationAllen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
More informationIn this section we tell you how to set the fault mode selection plug, key your I/O chassis, install your module and make your wiring connections.
Installation Data This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module using the indicators for troubleshooting
More informationCompact I/O Thermocouple/mV Input Module. Catalog Numbers 1769-IT6 User Manual
Compact I/O Thermocouple/mV Input Module Catalog Numbers 1769-IT6 User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More informationPowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit
Installation Instructions PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationCompact I/O End Caps/Terminators
Installation Instructions Compact I/O End Caps/Terminators Catalog Numbers 1769-ECL, 1769-ECR Topic Page Important User Information 2 Environment and Enclosure 3 North American Hazardous Location Approval
More informationSquare D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
More informationAbout the BitStorm 6051 POTS Splitter
BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service
More informationAnalog Input Module Cat. No. 1771 IFE User Manual
User Manual Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary
More informationMicro800 Programmable Controllers. Bulletin 2080 Selection Guide
Micro800 Programmable Controllers Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
More informationSLC 500 BASIC and BASIC-T Modules
Installation Instructions SLC 500 BASIC and BASIC-T Modules Catalog Numbers 1746-BAS and 1746-BAS-T Inside... For See Page Important User Information 2 Hazardous Location Considerations 3 Environnements
More informationPowerFlex 700S and 700H Frame 12 DC Bus Connector Kit
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives
More informationABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
More informationSCXI -1303 32-CHANNEL ISOTHERMAL TERMINAL BLOCK
INSTALLATION GUIDE SCXI -1303 32-CHANNEL ISOTHERMAL TERMINAL BLOCK Introduction This guide describes how to install and use the SCXI-1303 terminal block with SCXI-1102, SCXI-1102B, SCXI-1102C, and SCXI-1100
More informationTECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
More informationSLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade
Installation Instructions SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade Catalog Numbers 1747-DU501 Topic Page System Requirements 3 Install ControlFLASH 3 Prior to Running ControlFLASH
More informationUSB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address
More information1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
More informationUniversal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
More informationControlNet Standard and High-flex Coax Cable
Installation Instructions ControlNet Standard and High-flex Coax Cable Catalog Number 1786-RG6/A and 1786-RG6F/B About This Document This document contains application information you need to consider
More informationUniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
More information3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
More informationHIGH RELIABILITY POWER SUPPLY TESTING
HIGH RELIABILITY POWER SUPPLY TESTING Dale Cigoy Keithley Instruments, Inc. The reliability of a power supply must match or exceed the rest of the system in which it is installed. Generally, this requires
More informationManual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
More informationInstallation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.
Installation Instructions Differential Air-pressure Transmitter Catalog Numbers 1414-IPZ10FODAA, 1414-IPZ10FNDAA, 1414-IPD10FNRAA, 1414-CPZ10FODAA, 1414-CPZ10FNDAA, 1414-CPD10PNRAA Topic Page Before Installation
More informationAutomatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811
Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The
More informationSolid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationCurrent Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
More informationTraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to
More informationFiber Optic Cable Installation
Quick Guide Fiber Optic Cable Installation Introduction Fiber optic cables can be easily damaged if they are improperly handled or installed. It is imperative that certain procedures be followed in the
More informationInstruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationHP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
More informationAC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134
AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationFLEX I/O Isolated Analog Modules
FLEX I/O Isolated Analog Modules 1794-IF4I, -OF4I, IF2XOF2I, -IF4IXT, -IF4ICFXT, -OF4IXT, IF2XOF2IXT User Manual Important User Information Solid state equipment has operational characteristics differing
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationT0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
More informationAllen-Bradley/Rockwell
MANUFACTURER DATA SHEET PLC-CPU Manufacturer: Allen-Bradley/Rockwell Model Number: SLC500 See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014624-00 VendorPartNumber: 1747-L524
More informationSquare D Clipsal Two-Channel DIN-Rail DALI Gateway
Square D Clipsal Two-Channel DIN-Rail DALI Gateway SLC5502DAL for Use with C-Bus Wired Networks Instruction Bulletin Retain for future use. Square D Clipsal Two-Channel DIN-Rail DALI Gateway 63249-420-226A1
More informationPerle Protocol Transparent Media Converter Modules
Perle Protocol Transparent Media Converter Modules Installation Guide C-4GPT-DSFP CM-4GPT-DSFP Part# 5500335-10 Overview This document contains instructions necessary for the installation and operation
More informationRMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
More informationOPLC Installation Guide
Samba OPLC SM43-J-T20/ SM35-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs are set to pnp), 8 Relay Outputs 12 Digital
More informationApplication Technique. Safety Function: Magnetic Door Switch Monitoring
Application Technique Safety Function: Magnetic Door Switch Monitoring Products: MC1 Magnetically-coded Door Switch, Guardmaster Dual-input Safety Relay Safety Rating: CAT. 3, PLd to EN ISO 13849-1: 2008
More informationCurrent Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationPower Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
More informationWhale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
More informationFN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationModel UT33A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation
More informationDVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationSDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual January 2011 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationAdvantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationMeasuring Temperature withthermistors a Tutorial David Potter
NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in
More informationTechnical Note Series
Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationBODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More information10 Multimeter. Users Manual
10 Multimeter Users Manual 1991-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. 10 MULTIMETER m m Mk SELECT RANGE OFF VDC VAC
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationAchat 115MA full-range speaker. user manual
Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More information************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D
************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D INTRODUCTION Power Acoustik amplifiers provide high-performance
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationSNQ-60x0-320 Series Data Center Switch. Quick Installation Guide
Introduction This guide is to assist the reader with the most basic form of installation and connection to switches in this series. As there is more than one switch in this series, the diagrams might slightly
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More information1701/22 FieldMonitor Management Interface Module
1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides
More informationAXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
More informationAC and DC Drive System Installation Information
Purpose This document contains the Parker SSD Drives recommendations for installing drive systems. These instructions must be followed for safe and reliable operation. Instructions CODES AND REGULATIONS
More informationHMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
More information7 FUNCTION DIGITAL MULTIMETER
7 FUNCTION DIGITAL MULTIMETER 90899 OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools. All rights
More informationPS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS
More informationTroubleshooting accelerometer installations
Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most problems.
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationMIC-BP4 Bi-Phase Converter Card For the MIC400 series camera
MIC-BP4 Bi-Phase Converter Card for the MIC400 PTZ Camera Series Bosch Security Systems EN Installation and Operation Manual BP4 Bi-phase card Installation and Operation Manual AAAEN 2 MIC-BP4 Bi-Phase
More informationConsiderations When Specifying a DC Power Supply
Programming Circuit White Paper Considerations When Specifying a DC Power Supply By Bill Martin, Sales/Applications Engineer Every automated test system that tests electronic circuit boards, modules or
More informationMoxa EtherDevice Switch
Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More informationPT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
More informationPART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
More informationRadiant Temperature Sensor TY7321
AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional
More informationMODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
More informationSubminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
More information