SERVICE MANUAL DGK100D DGK100DU
|
|
- Horatio Gaines
- 7 years ago
- Views:
Transcription
1 SERVICE MANUAL DGK100D DGK100DU WARNING This equipment is designed and built with safety in mind. However, your overall safety can be increased by your full understand followed by the content in this manual. Read this manual and familiarize yourself with its contents for your safety. This equipment should only be operated and maintained by trained and qualified personnel. This equipment is designed for generating power source of electric tools, home appliances and lights. Do not install, operate or service this equipment without reading this manual and unless you clearly understand this manual. Specifications subject to change without notice. File DG0-182_DGK100D, DGK100DU
2 This service manual is edited for authorized person to perform repair, maintenance, and trouble-shooting to Shindaiwa diesel engine generators, designated as DGK100D and DGK100DU. It is inevitably necessary to maintain and adjust shindaiwa products periodically in order to use fully and safely for long time. Therefore, understand this service manual fully enough before use and proper maintenance. The information contained in this service manual describes equipment available at the time of publication. While every attempt has been made to give you the very latest information about your product, there may be some differences between your equipment and the equipment described in this manual. We reserve the right to make changes to equipments without prior notice, and without obligation to make alterations to equipments previously manufactured. For service of the engine, refer to Workshop (Service) Manual provided by the engine manufacturer described below. MANUFACTURER ISUZU MODEL BI-4HK1
3 Table of Contents 1. Attention Statements 1 2. General Safety Instructions 2 3. Specifications 4 4. General Appearance Dimension 5 5. General Parts Description Main Parts and Feature Main Components 7 6. Service Data Technical Specification Generator 14 (1) Exciting Amperage 14 (2) Resistance Value 14 (3) Technical Specifications Tightening Torque Technical Specification Technical Specification Periodical Check for Engine Trouble Shooting Wiring Diagram 22 File DG0-182_DGK100D, DGK100DU
4 1. Attention Statements Technicians only who own enough knowledge and experience should work for maintenance and operational check after maintenance. Before maintenance, always read this service manual as well as owner s manual and familiarize contents thoroughly before starting the service and maintenance of the equipment for understanding of the equipment, safety instructions and cautions. Throughout this manual are special attention statements. WARNING A statement preceded by the triangular attention symbol and the word WARNING contains information that should be acted upon to prevent serious bodily injury. CAUTION A statement preceded by the triangular attention symbol and the word CAUTION contains information that should be acted upon to prevent mechanical damage. 1
5 2. General Safety Instructions ELECTRIC SHOCK NEVER touch the output terminals during operation NEVER touch the output terminal during operation even though the breaker on the load is being set at OFF position. ALWAYS stop engine and make sure it stopped before you will connect the loads to the output terminals. WARNING By Entangled Injuries under Moving Component NEVER reach and touch the moving component during operation! ALWAYS stop the engine during inspection to prevent serious bodily injury by entangled accident under moving component. Electric shock/injuries/burns Suffocation by exhaust gas NEVER run the engine indoors! Make sure there is always good ventilation. Fumes from engine exhaust cause serious injury. ALWAYS operate the equipment in the ventilated area. When the equipment is used in a tunnel, hall or any other indoor, the equipment for ventilation must be used to prevent serious accident caused by suffocation. NEVER direct the exhaust fume to houses nearby while considering the wind flow direction. Exhaust gas contains many harmful elements that would cause affect to human. Be free from suffocation when the equipment is used in poorly ventilated area such as inside of the building. 2 Never inspect equipment during use. Never serve and inspect when equipment is being operated. It may cause electric shock, injuries or burns. WARNING-Use good judgment 1 NEVER run the engine when transporting the equipment. 2 ALWAYS stop the equipment immediately if it suddenly begins to violate or abnormal noise. Inspect for broken, missing or improperly installed parts. 3 ALWAYS keep the equipment as clean as practical. Keep it free of loose vegetation, mud, etc. DO NOT make unauthorized modifications or alterations to this equipment of any of its components. YAMABIKO must authorize alterations and modifications in writing. Unauthorized modifications or alterations may alter the equipment operation and could jeopardize personal safety during operation.
6 CAUTION Work Safely STOP the equipment immediately when Generators and welders operate at very high abnormal circumstances are noticed! speeds and can do serious damage or injury STSTOP the equipment immediately whenever if they are misused or abused. Never allow a abnormal circumstances are noticed such person without training or instruction to as unusual noise, smell, vibration and etc. operate and serve this equipment! It may lead serious accident or fatal damage Attention to CAUTION LABEL! of the equipment or properties. Caution labels are placed on this equipment and it would request special attention for operation. Make sure to locate the labels and understand the content of the caution. Check the caution labels is legible. Always keep the labels clean or replace them when worn or damaged Clean the labels by cloth, water or detergent and never use organic solvent or gasoline which may cause label peel off due to adhesive solvent. Make sure to replace the labels when damaged and illegible. Before replacing the label(s), make sure to place the new label(s) in the same position. Inflammables! Keep the equipment far away from fire such as cigarettes when refueling fuel, oil or battery fluid. NEVER operate or service the equipment nearby fire as the equipment may catch fire. No Modification! NEVER modify the equipment without manufacturer s advanced approval.. It may lead serious safety issue and damage the equipment. Inspect the equipment before engine start for operation and periodical inspection without fail! Make sure to serve initial check before start engine and periodical inspection for safety and longer life of the equipment. 3
7 3. Specifications Unit DGK100D/DGK100DU Generator Engine Dimension Revolving Filed, Brushless AC Generating Method - 3-Phase-120/240V, 1 Phase kva 100 Rated Output kw 80 Rated Voltage Rated Current 3-Phase 208, 240, 480 V 1-Phase 120, 139, 240, Phase-120V 242 x 2 (Zigzag) 1-Phase-240V 242 (Zigzag) A 3-Phase-240V Phase-480V 120 Rated Frequency Hz 60/50 (± less than 0.25%) Rated Speed min /1500 Winding - Star with Neutral Power Factor % 80 Insulation Class - Alternator: F Exciting Method - Self Excitation (Brushless) No. of Poles - 4 Method - Vertical, Water-cooled 4-Cycle, Diesel Engine Model No. - ISUZU BI-4HK1 No. of Cylinder (bore x stroke In./mm 4 (4.53 x 4.92/115 x 125) Continuous Rated Output kw{ps} 114.7{155.1}/1800 min -1 Rated Speed min /1500 Displacement Liter 5,193 Combustion System - Direct Injection, Turbo-charged, Inter-cooler Cooling Method - Water-cooling radiator Lubricating - Forced lubrication Starting - Electric Fuel - ASTM No.2 Diesel Fuel Consumption Liter 23.4/h (@full load) Lubricating Oil - SAE Class CD or higher Fuel Tank Capacity Liter 222 Lubricant Volume Liter 22 Coolant Volume Liter 23 Starting Motor Capacity V-kW 12V 2.5kW Alternator Capacity V-A 12V 110A Battery Capacity V-AH 12V 150AH Length in/mm 102/2590 Width in/mm 49/1240 Height in/mm 71/1800 Dry Weight lbs/kg 4564/2070 * Specifications subject to change without notice. 4
8 4. General 4.1 Appearance 4.2 Dimension Unit in the drawings below is shown by mm. 5
9 EXHAUST GAS OUTLET AIR OUTLET WATER INLET 6
10 5. General Parts Description 5.1 Main Parts and Feature (1) Serial Number Unit Serial Number Engine Serial Number 5.2 Main Components Pilot Lamp Feature: Indicate when generator run. Main Circuit Breaker Feature: Protect an electrical circuit from damage by overload or short circuit. Panel Light Feature: Illuminate the control panel to indicate that power is generated. Panel Light Switch Feature: Illuminate the control panel when the panel light switch is ON. Monitor Lamp Feature: Light a monitor lamp when equipment is malfunctioned. Hour Meter Feature: Display running hour of the engine. Voltage Selector Switch Feature: Select the output phase voltage as displayed. Glow Lamp Feature: Pre-Heating lamp is ON when a starter switch is turned to PREHEAT position. 7
11 This unit is equipped with monitoring functions and the cautioned lamp flashes to indicate defect. Investigate and correct cause(s) when any of the monitor lamp ON. 7 DIAG (Diagnosis): when an electronic control module defects. Engine will NOT automatically shut down. AIR FILTER: when the oil filter is clogged, clean or replace the filter. Engine will NOT automatically shut down. BOOST: when temperature of the manifold temperature exceeds 85. CHARGE: when a battery charge is insufficient. OIL PRESS: when oil pressure drops below 14.5 psi. Engine will automatically shut down. OVER HEAT: when temperature of the coolant will reach to 105. Engine will automatically shut down. OVER SPEED: when the engine speed exceeds 2,070 min -1. Engine will automatically shut down. Monitor Lamp Feature: Light a monitor lamp when equipment is malfunctioned. Volt Meter Selector Switch Feature: A switch to change voltage. Ampere Meter Selector Switch Feature: A switch to select the output current. Voltage Meter Feature: Display the output voltage from the generator. Ampere Meter (AC) Feature: Display the output current (phase) from the generator. Frequency Meter Feature: Display the frequency of the generator. AC Voltage Adjusting Dial Feature: A dial to adjust AC output. Water Temp. Meter Feature: Display water temperature in the radiator. Oil Pressure Meter Feature: Display oil pressure. Fuel Meter Feature: Display volume of the fuel left in the fuel tank. Decrease Increase Throttle Switch Feature: Change the engine speed. 8
12 Left Door View Output Terminal Cover Inside Terminal Rest Feature: Relay terminal block of the power output from the alternator. Circuit Breaker (1-Phase) Feature: Protect electrical circuit from damage caused by overload or short-circuit. Circuit Breaker (1-Phase) Feature: Protect electrical circuit from damage caused by overload or short-circuit. 1-Phase Receptacle (20A) Feature: Supply AC output. 1-Phase Receptacle (20A) Feature: Supply AC output. 3-Phase Circuit Breaker A (120/240V) Feature: Protect electrical circuit from damage caused by overload or short-circuit. 3-Phase Circuit Breaker B (120/240V) Feature: Protect electrical circuit from damage caused by overload or short-circuit. 1-Phase Receptacle A (30A) (120/240V) Feature: Supply AC output. 3-Phase Circuit Breaker C (120/240V) Feature: Protect electrical circuit from damage caused by 1-Phase Receptacle B (30A) (120/240V) Feature: Supply AC output. 1-Phase Receptacle C (30A) (120/240V) Feature: Supply AC output. Note: All duplex receptacles are GFCI protected and are rated at 20 amps. Other twist and lock type receptacles are rated at 30 amps (DGK100DU), 50amps (DGK100D). 9
13 Sub Tank - Coolant Feature: Keep coolant water level in the radiator. Air Cleaner Feature: Clean intake air. Alternator Feature: Charge a battery and send a charging signal. Pre Fuel Filter Feature: Filter water or dust in the fuel. Oil Filter Feature: Remove solid particulates such as dust in the oil. Main Fuel Filter Feature: Filter water or dust in the fuel. External Fuel Return Feature: Outlet to return fuel from external tank. Fuel Drain Plug Feature: Drain the old fuel from the fuel tank. External Fuel Inlet Feature: Inlet to refuel from the external tank. Coolant Drain Hose Feature: Drain coolant from the top cover. Oil Drain Plug Feature: Drain the old oil from the oil tank. CAUTION Connect pipes for the external fuel return and fuel inlet correctly with the external tank to avoid mechanical damage. 10
14 Fuel Inlet Feature: Inlet to refuel. 3-Way Valve The 3-way fuel valve is located underneath on the right side of the engine. 3-Way Valve Feature: Change fuel supply from a built-in or external fuel tank. 3-Way Valve Position A (to use external fuel tank): Position a 3-way valve lever to LEFT to use fuel from external fuel tank. Position B (to use a built-in fuel tank): Position a 3-way valve lever to RIGHT to use fuel from a built-in fuel tank. Note: The valve is positioned at position B when a unit is delivered from the factory. CLOSE OPEN CLOSE OPEN WARNING Always stop engine prior to changing the 3-way valve lever position. (Photo: Position B-for a built-in tank) Turn both green and orange plugs clockwise to open the valves when the 3-way valve is positioned in position A. So, fuel from the external tank will circulate. Turn both green and orange plugs counter-clockwise to close the valves when the 3-way valve is positioned in position B. So, circulation with the external tank is shut down. 11
15 Injection Pump Feature: Supply fuel to the injection nozzle. Right Door Inside View Accessory Standard Accessory 1 Owners Manual 2 Starter Key 2 sets 3 Warranty Statement 4 Instruction Manual of the engine 6. Service Data 12
16 ELECTRIC SHOCK WARNING Never touch the output terminals during operation. Never touch the output terminal during operation even though the breaker on the load being set at OFF. Be sure to check and confirm the engine stop whenever touching terminals to connect loads. 6-1 Technical Specification Items Reference Value Note Insulation Armature DC500V winding 3MΩ or more Megger Tester Exciter field Preheat time would be approx. 8 sec. Preheat time when coolant temp. read -15 and Automatic preheat it would be 1 sec. when coolant temp. system read 20. Glow lamp ON for 10 sec. Min. rpm at no load 1000±25 min -1 Max. rpm at no load 1500 min -1 50Hz 1800 min -1 60Hz Lubricant oil pressure 0.2~0.6MPa{2~6kgf/cm²} Coolant temperature 70~100 Frame temperature limit within 80 Sealed bearing temperature limit within 80 Speed regulation Momentary within 10% Steady-state deviation within 5% Momentary within 20% Voltage regulation Frequency Steady-state deviation within 1.0% Idle: 33.3 Hz Rated: 60 Hz Variable voltage 374~448V 50Hz 408~504V 60Hz Protective device Low oil pressure Working pressure Low oil pressure Working pressure 0.1MPa{1.019±0.2kgf/cm²} [Close] when activated High water temp. Working temperature Generator 13
17 (1) Exciting Amperage Amperage fluctuates based upon the winding temperature. Following is for reference only. Frequency/Rated Output Load Exciting Amperage (Measured) 3-phase 50Hz: 64 kw 60Hz: 80 kw No load 1.03A Full load( power factor=1.0) 1.40A No load 0.76A Full load( power factor=1.0) 1.22A (2) Resistance Value Nominal resistance of the winding is tolerated within ± 10% at 20 of the ambient temperature. The resistance must be measured by low resistance tester. It can not be measured by multi-purpose tester cause of index error. Measurement value (Ω) Armature Between T 1 -T 4,T 7 -N 10 (U) T 2 -T 5,T 8 -N 11 (V) T 3 -T 6,T 9 -T 12 (W) Generator Exciter (Measured) Stator Rotor Stator Rotor Exciter armature Exciter Field J-K Armature (3) Technical Specifications Items Article Method Condition to verify Criterion Check before operation Shape, Dent, Blot Coating Joint Oil, Coolant Wiring Visual Inspection No dent, blot and deformation No looseness Meet the criteria Meet the required level Lead wires to be securely fastened against abrasion and damage to bring by vibration Grounding Insulation Check Continuity Insulation Resistance Tester Optional Tester Bonnet Grounding Terminal Engine Lead Wire Bonnet Grounding Terminal Receptacle Bonnet Grounding Terminal Lead Wire In the base Main and 1-phase breaker 50A ON and 1-phase breaker 20A OFF. Disconnect the coupler in the stator (9P). Continuity is to be confirmed Over 3MΩ Dielectric Voltage Tester Disconnect all wires in the AC2400V (1 sec) or AC1960V (1 min) terminal block. 14
18 Monitor Glow Lamp Battery Charge, Oil Pressure, Hour Meter Visual Inspection Starter Switch is at PREHEAT position Starter Switch is at RUN position Engine Running Preheat Lamp ON for 10 seconds Charging Lamp ON, Hour Meter is activated. DIAG lamp turns ON and then, it turns OFF. All monitor lamps OFF and Hour Meter is activated. Pilot Lamp ON during engine run. AIR FILTER lamp ON when terminals (black/yellow wires)in the air cleaner indicator are grounded. Protection Circuit Thermal Relay Terminal Cover Emergency Stop Phase rotation AVR Adjustment Visual and hearing Phase Rotation Indicator Voltage- Meter Engine Stopping Engine Running Engine Running Output selector switch is set at 208V (3-phase) No Load Voltage Adj. Dial: Max Thermal relay is set at 4.0A and auto return. Main breaker lever trips in the middle of the ON and OFF position when a test trip lever trips to TRIP. Main breaker lever trips in the middle of the ON and OFF position. OVER SPEED lamp ON and engine stops at 1725±25rpm. - Rotate as arrow shows Frequency (Hz) 60±0.1 Output (V) 253±2 *Adjust by VOLT ADJ. volume in AVR. (Ref. *6) Engine Control Switch OFF, Throttle RUN, Engine Speed 1800rpm. Operational Check 3-Phase Output (Comprehensive Voltage Regulation) 3-Phase Output (Continuous Operation under Loaded) Load Tester Frequency Meter Wattmeter DC Amp. Meter Load Tester Frequency Meter Wattmeter Stop Watch Output selector switch is set at 480V. (3-phase) Output: 80.0+/-0.8kW Voltage: 480+/-1V Frequency: 60+/-0.1Hz Power Factor: 1.0 % kw V A Hz / /-1 (1.22) /-0.6 (1.16) /-0.4 (0.89) 480+/ /-0.2 (0.80) 0 no load (0.76) 60+/-0.2 Engine Control Switch OFF, Throttle RUN, Engine Speed 1500rpm. Output selector switch is set at 480V. (3-phase) Output: 64.0+/-0.6kW Voltage: 440+/-1V Frequency: 50+/-0.1Hz Power Factor: 1.0 % kw V A Hz / /-1 (1.40) /-0.5 (1.27) /-0.3 (1.15) 440+/ /-0.2 (1.06) 0 no load (1.03) 50+/-0.2 Engine Control Switch OFF, Throttle RUN, Engine Speed 1800rpm. Output selector switch is Set at 208V, 3 phase. Output: 40.0+/-0.6kW Voltage: 240+/-1V Frequency: 60+/-0.1Hz Power Factor: 1.0 Engine Control Switch OFF, Throttle RUN, Engine Speed 1500rpm. Output selector switch is Set at 208V, 3-phase. Output: 32.0+/-0.5kW Voltage: 220+/-1V Frequency: 50+/-0.1Hz Power Factor: 1.0 *1 *2 15
19 Engine Control Switch OFF, Throttle RUN, Engine Speed 1800rpm 3-Phase Output (Transient Load Change Excursions) Load Tester Frequency Meter Wattmeter Stop Watch Output selector switch is Set at 208V, 3-phase. Output: 80.0+/-1.2kW Voltage: 240+/-1V Frequency: 60+/-0.1Hz Power Factor: 1.0 Engine Control Switch OFF, Throttle RUN, Engine Speed 1500rpm Output selector switch is Set at 208V, 3-phase. Output: 64.0+/-1.0kW Voltage: 220+/-1V Frequency: 50+/-0.1Hz Power Factor: 1.0 *3 *4 Engine Control Switch OFF, Throttle RUN, Engine Speed 1800rpm Single Phase Output Output selector switch is Set at 240/120V, 1-phase. Voltage: 240+/-1V Frequency: 60+/-0.1Hz Power Factor: 1.0 No Load 50A Receptacle Output Voltage (X-Y) 240+/-3 AC Voltagemeter Engine Control Switch OFF, Throttle RUN, Engine Speed 1800rpm (60Hz), 1500rpm (50Hz) Voltage Adjustment Output selector switch is Set at 480V, 3-phase. Turn Voltage Adjusting Dial at no load. No Load Voltage (V) Max. Min. 60Hz over 504 blow Hz over 448 blow 374 Operational Check Engine Speed Adjustment Continuous Load Operation Digital Tachometer Wattmeter Frequency Meter Oil Pressure Meter Water Temp. Meter Wet/Dry Thermometer Stop Watch PC EMPS III Adjust engine speed by engine control switch in control box at no load. Engine Control Switch OFF, Throttle START Idle Speed (min -1) 1000±25 *5 *5 Piping to External Fuel Supply External Fuel Tank - Fuel is to be sucked up from the fuel tank and returned to the tank. Other Frequency Hz setting is confirmed. Fuel Meter Visual Inspection Drain fuel from the tank and confirm the fuel meter. The fuel meter indicates E when empty. 16
20 *1 Criterion Mode Frequency (Hz) Setting Time Loaded No Load (Transient Max.) below 66 below 8 sec. No Load 60+/ No Load Loaded (Transient Min.) over 54 below 8 sec. No Load 60+/ *2 Criterion Mode Frequency (Hz) Setting Time Loaded No Load (Transient Max.) below 55 below 8 sec. No Load 50+/ No Load Loaded (Transient Min.) over 45 below 8 sec. No Load 50+/ *3 Criterion Mode Output Voltage (V) Setting Time Frequency (Hz) Loaded No Load (Transient Max.) below 288 below 2 sec. - No Load 240+/-3-60+/-0.2 No Load Loaded (Transient Min.) over 192 below 2 sec. - No Load 240+/-3-60+/-0.2 *4 Criterion Mode Output Voltage (V) Setting Time Frequency (Hz) Loaded No Load (Transient Max.) below 264 below 2 sec. - No Load 220+/-3-60+/-0.2 No Load Loaded (Transient Min.) over 175 below 2 sec. - No Load 2240+/-3-60+/-0.2 *5 Output Selector Switch is set at 208V, 3-phase Engine Control Switch OFF, Throttle RUN, Engine Speed 1800rpm, Speed Manual ON Criterion Room Temp. kw** V** Hz** PF* Oil Pressure Water Temp. 5~ / ~ / /-1 60+/ ~6 MPa 85~99 25~ /-0.1 * PF stands of power factor. **Connect PC and a connector for TECH2 and check engine and harness by EMPSⅢ. ***Measure rpm after operation at no load for 30 min. ***Engine RPM (No Load) 1890 min -1 or less *6 17
21 7. Tightening Torque 7-1 Specific Tightening Torque No Nomenclature Part to be tighten Size 1 Exciter Stator Bolt M5x Rear Bracket (Main Stator) 3 Generator Stator Qty Bolt M12x160 4 Bolt, Shim M10x Rotor Bolt M10x1.25x Fan 6 Front Bracket (Alternator Assy to install) Bolt, Shim M8x25 6 Bolt M10x1.25x Engine Stay Bolt M10x1.25x Thyristor (Stuck Fin) 9 Socket 10 Flexible Tube Terminal Rest (Welding Terminal) Battery (Terminal Attachment) Battery (Wiring) Glow Plug (Terminal) Oil Pressure Switch Screw, Shim Drain Plug Flange Nut M6x20 4 M12x1.25x13 3 M8 6 Nut M10 4 Nut M8 2 Nut M8 2 Nut M4 1 Bolt, Shim M4x Fuel Strainer Bolt M8x65 1 Torque Allowance Nm(kgf/cm) (30-50) ( ) ( ) ( ) ( ) ( ) ( ) (25-35) ( ) ( ) ( ) (50-62) (70-90) (10-18) (14-20) ( ) Reference 7T 7T Small Head (Opposite Side Distance 14) Brass Battery Accessory Battery Accessory Engine Accessory Engine Accessory Opposite Side Distance 12 Note: Refer to the following General Tightening Torque for the general torques that are not specified above. 18
22 7-2 General Tightening Torque unit: N m {kgf cm} Intensity 4.6, 4.8, 5.6, 5.8, 6.3 (4T, 5T, 6T) 8.8, 9.8, 10.9, 12.9 (7T) Nominal Designation M3 0.5 Nominal 0.6 {6} Tightening Torque Allowance Limit 0.5 ~ 0.8 {5 ~ 8} Tightening Strength N{kgf} 845 {86} Nominal 1.2 {12} Tightening Torque Allowance Limit 1.0 ~ 1.5 {11 ~ 15} Tightening Strength N{kgf} 1610 {164} M {15} 1.3 ~ 1.9 {14 ~ 19} 1475 {150} 2.8 {29} 2.8 ~ 4.8 {29 ~ 49} 2810 {287} M {30} 2.6 ~ 3.8 {27 ~ 39} 2386 {243} 5.7 {58} 4.8 ~ 7.1 {49 ~ 72} 4544 {463} M {52} 4.3 ~ 6.4 {44 ~ 65} 3377 {344} 9.6 {98} 8.6 ~ 14.4 {88 ~ 147} 6432 {656} M {125} 11 ~ 16 {112 ~ 163} 6149 {627} 23 {239} 20 ~ 30 {204 ~ 306} {1194} M {248} 21 ~ 31 {214 ~ 316} 9744 {994} 46 {473} 40 ~ 60 {408 ~ 612} {1893} M {433} 37 ~ 54 {377 ~ 551} {1444} 81 {825} 70 ~ 100 {714 ~ 1020} {2751} M {690} 60 ~ 85 {612 ~ 867} {1970} 129 {1313} 110 ~ 160 {1122 ~ 1632} {3753} M {1076} 90 ~ 130 {918 ~ 1326} {2690} 201 {2049} 170 ~ 250 {1734 ~ 2549} {5123} M {1480} 125 ~ 180 {1275 ~ 1835} {3289} 276 {2819} 235 ~ 345 {2396 ~ 3518} {6265} M {2099} 175 ~ 260 {1785 ~ 2651} {4197} 392 {3997} 335 ~ 490 {3416 ~ 4997} {7995} M {2855} 240 ~ 350 {2447 ~ 3569} {5191} 533 {5438} 455 ~ 665 {4640 ~ 6781} {9887} M {3628} 305 ~ 445 {3110 ~ 4538} {6047} 678 {6911} 575 ~ 845 {5863 ~ 8617} {11519} Material SS, S C, SWRM, SWCH NC, SNCM, SCM (hardening & tempering treated) Note: Refer to the following General Tightening Torque for the general torques that are not specified above 19
23 8. Periodical Check for Engine Consult Service Dealer User Check Replace Parts Items Start up Check At 50hrs Every 100hrs Checking interval Every 200hrs Every 400hrs Every 1000hrs Every 2000hrs 1 Check and Supply Fuel 2 Check and Supply Engine Oil 3 Change Engine Oil 1 st 2 nd 4 Oil Filter Change 1 st 2 nd 5 Check/Add Coolant 6 Coolant Change or 2 years 7 Clean Fuel Filter 1 st 2 nd 8 Change Fuel Filter 9 Drain Water/Clean Fuel Tank 10 Check Leakage Fuel, Oil, Water 11 Check/Add Battery Liquid 12 Clean Air Element 1 st 2 nd 13 Change Air Element 14 Adjust tension V-belt 1 st 2 nd 15 Change V-belt or 2 years 16 Clean Radiator Fin 17 Clean Radiator inside 18 Change Fuel Hose, Oil Hose, Vibration-absorbing Rubber or 2 years 19 Adjust Engine Valve Clearance Adjust Plane 20 Check/Adjust Injection Nozzle 21 Check/Adjust Injection Pump 20
24 9. Trouble Shooting <Pre-check> Always check the volume of oil, coolant, and fuel before processing to trouble shooting. Problem Possible Cause Inspection Remedy No output voltage. 1. Faulty volt meter. 2. Faulty generator. 1. Check the volt meter voltage. 2. Verify the exciting amperage and 1. Replace the volt meter. 2. Replace the generator. resistance value. No voltage increase 1. Faulty volt meter. 2. Faulty generator. 1. Check the volt meter voltage. 2. Verify the exciting amperage and 1. Replace the volt meter. 2. Replace the generator. the value of resistance. 3. Faulty AVR or voltage 3. Broken wires, loose or disconnected 3. Repair or replace the parts. adjuster. cable. 4. Adjust the rotation speed 4. Slow rotation. 4. Check the rotation speed of the of the engine properly. engine. 5. Repair. 5. Faulty initial 5. Broken or loose the wire. excitation. High output voltage. 1. Faulty volt meter. 1. Check the voltage of the volt meter 1. Replace the volt meter. 2. Faulty adjusting AVR. 2. Check the dial gauge [VR1] on the 2. Adjust the voltage properly. AVR. 3. Broken wire, loose 3. Check wiring of voltage adjuster. 3. Inspect and repair the or disconnected Single wire disconnected: 240 to 280V. cable. cable of the voltage Double wire disconnected: 260 to 300V. adjuster circuit. Abnormal frequency 1. Unbalanced load. 1. Check the amperage of each 1. Balance the current. or voltage drop 2. Low rotation speed. phase. when load is 2. Check the rotation speed. 2. Adjust appropriate speed. increased. 3. Over load. 3. Check the amperage of each 3. Decrease the load. phase. Can't be turned on 1. The handle of the 1. Check the position of the handle. 1. Press the handle to the the circuit breaker. breaker is positioned [OFF] position first, then set between [ON] and the handle to the [ON] [OFF] position. position to reset. 2. Over load. 2. Check the load. 2. Decrease the load. 21
25 10. Wiring Diagram 22
26 23
27 24
28 YAMABIKO CORPORATION 35 SHIN-UJIGAMI, KITA-HIROSHIMA-CHO, YAMAGATA-GUN, HIROSHIMA JAPAN Telephone: (81) Fax: (81)
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationTurbocharger system components, servicing
21-1 Turbocharger system components, servicing Engine codes: AAZ, 1Z, AHU Observe rules of cleanliness Page 21-10 Turbocharger hoses and lines, connecting Page 21-11 WARNING! Do not re-use any fasteners
More informationaccidents which arise due to nonobservance and the safety information herein.
20 GALLON COMPRESSOR Model: 7342 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This
More informationPANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual
PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual A Regal Brand TABLE OF CONTENTS INTRODUCTION 2 General Data 2 Initial Inspection 2 SAFETY 2 INSTALLATION 3 Location / Environment
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationCDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
More informationTrouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
More informationSplit-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
More informationChapter 7 Hydraulic System Troubleshooting
Chapter 7 Hydraulic System Troubleshooting General The following troubleshooting information is provided as a general guide to identify, locate and correct problems that may be experienced with the hydraulic
More information01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09
0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by
More informationCARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
More informationGENERATOR MODEL NO: FG3050 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: 8857705 LS0310
GENERATOR MODEL NO: FG3050 PART NO: 8857705 OPERATION & MAINTENANCE INSTRUCTIONS LS0310 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this
More informationRexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
More informationUSER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
More information14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
More informationDoc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
More informationHow To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationNewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
More informationTIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
More informationUser s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
More informationSBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
More informationSafety, Operation and Maintenance Manual with Parts List
Safety, Operation and Maintenance Manual with Parts List 20-Gallon Wet/Dry Vac Important Information and Safety Instructions PLEASE READ BEFORE USE! # 961130020 9/10-Rev 1 20-Gallon Wet/Dray Vac TABLE
More information800-292-3279 916 638-0828
800-292-3279 916 638-0828 http://easycleansystems.com/heaters/heater-parts.html VAL6 KBE5S and KBE5L Service manual KBE5S 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel
More informationON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
More informationAnnex-A TECHNICAL SPECIFICATION
Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery
More informationUser s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationTable V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
More informationDiesel Generating Set
MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V
More informationREMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
More informationVolkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
More informationBC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.
BC-5000 BATTERY CAPACITY TESTER OPERATIONS MANUAL COFKO LLC. COPYRIGHT 2010 1 UNPACKING As you unpack your new BC-5000 battery capacity tester, inspect the tester for signs of shipping damage. If shipping
More informationINSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions
More informationService manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
More information12. Inspection and Maintenance
12. and Maintenance Mandatory Be sure to inspect the inverter regularly and periodically to prevent it from breaking down because of the environment of use, such as temperature, humidity, dust and vibration,
More informationHydraulic Trouble Shooting
Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders
More informationOPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
More informationMagnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
More informationEPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationThe Aftertreatment System Technician's Guide has been revised.
NUMBER: 2 ATS 07 S.M. REF.: Listed in Table 1 ENGINE: ATS DATE: April 2007 SUBJECT: UPDATES TO AFTERTREATMENT SYSTEM TROUBLESHOOTING PUBLICATION: 7SE63 The Aftertreatment System Technician's Guide has
More informationTechnical Guide 08/15/14
Technical Guide 08/15/14 1 Table of Contents Contact information.3 Identifying your system..4-8 Model Number Serial number location Parts of your fuel system..9-14 Fuel pump diagram Wire harness schematics
More informationOperating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
More informationSunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
More informationPortable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
More informationINSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL
INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL 15-LITER, 20-LITER, 35-LITER, 45-LITER, 60-LITER & 100-LITER SECTION 1 Basic Operation SECTION 2 Cleaning and Storing SECTION 3 Basic Trouble
More informationUSER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationREFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca
More informationAir Vantage 500 Kubota
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-625 P-625 RETURN TO MAIN INDEX PARTS LIST FOR Air Vantage 500 Kubota P-625-A
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationAGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ
Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Standard Features 3 Cylinder Diesel Engine for maximum durability, reliability and efficiency. Brushless alternator
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationSingle-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
More informationA/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
More informationAir Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
More information01 12 COOLING SYSTEM COOLING SYSTEM. End of Toc. End Of Sie
LOCATION INDEX. 1 SERVICE WARNINGS...................... 2 ENGINE COOLANT LEVEL INSPECTION..................... 2 ENGINE COOLANT PROTECTION INSPECTION..................... 2 ENGINE COOLANT REPLACEMENT..
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationNational- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
More informationOregon Fuel Injection
FORD POWERSTROKE DIAGNOSTICS 1994-2003 This guide is not a substitute for the proper diagnostic manuals and a scan tool. It is intended to be used with the proper tools to help diagnose and solve drivability
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw
,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted
More information12V Portable Diaphragm Compressor Operating and Maintenance Instructions
12V Portable Diaphragm Compressor Operating and Maintenance Instructions (Part No. DC2) Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Guidelines for Product Use...2 Operation
More informationDLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw
DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel
More information120Volt 60-70A ARC WELDER. 80000 Rev 80000-20080214
80000 Rev 80000-20080214 10006 Santa Fe Springs Road Santa Fe Springs, CA 90670 USA Made in China Owner s Manual and Operating Instructions 120Volt 60-70A ARC WELDER Table of Contents Introduction...
More informationManual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
More informationAir conditioning, electrical testing
just a test. Air conditioning, electrical testing 01-253 Wire and component test using VAG1598 A test box Special tools and equipment VAG 1598 A test box and VAG 1598/11 adapter cable and VAG 1598/12 VAG1526
More informationCOOLING SYSTEM Section Page
5 COOLING SYSTEM Section Page 5.1 COOLANT PRE-HEATER... 5-3 5.2 COOLANT PUMP NON-EGR ENGINE... 5-7 5.3 COOLANT PUMP EGR ENGINE... 5-13 5.4 FRONT CONNECTOR HOUSING NON-EGR ENGINE... 5-17 5.5 FRONT CONNECTOR
More informationPortable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.
OFF COOL 0 3 2 1 OFF Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use ON SPEED ON SWING OWNER S MANUAL Read and save these instructions before use Model: CO60PM Power rating: 220 Watts
More informationBC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
More informationBench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
More informationOPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationVolkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
More informationUSER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions
USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE AeroVironment EV Solutions 2013 AeroVironment, Inc. All rights reserved. AeroVironment, EV Solutions, and the AeroVironment logo are trademarks
More informationA.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line
More informationP 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationOPERATING & MAINTENANCE AIR COMPRESSOR RANGER 35 INSTRUCTIONS. Part No: 2331000
RANGER 35 AIR COMPRESSOR Part No: 2331000 OPERATING & MAINTENANCE INSTRUCTIONS 1102 Clarke International. All rights reserved. Dec. 1998 2 SPECIFICATIONS Rotational Speed... 2850 rpm Max. Pressure... 8
More informationEVAPORATIVE AIR COOLER INSTRUCTION MANUAL
EVAPORATIVE AIR COOLER INSTRUCTION MANUAL Model: SF-614P Please read this manual thoroughly before using this product. Keep in a safe place for future reference. CONTENTS A. PRODUCT INTRODUCTION 2 B. TECHNICAL
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
More informationPUMP MAINTENANCE SCHEDULE AND CHECKLISTS
PUMP MAINTENANCE SCHEDULE AND CHECKLISTS Providing a maintenance schedule defined specifically by run hours or yardage pumped serves only as a general guideline given the large amount of variables a unit
More informationMACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent
More informationThermo Top - Troubleshooting Tree
Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may
More informationHow To Service A Paper Shredder
Paper shredder 20-2HS 80C POWERSHRED OPERATING INSTRUCTIONS NOTICE D'UTILISATION MANUAL DEL PROPIETARIO BETRIEBSANLEITUNG 20 80 20C 80C 20-2HS Edition 0/0.70.999.0 Edition 0/0 20-2HS 80C Paper shredder
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
More informationINVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.
INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. GENERATOR SAFETY EXHAUST GAS PRECAUTIONS Only use outdoors! Exhaust fumes can
More informationMaintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / 1000 1SC / 1000 2SC / 1250SC / 1600SC / 1800SC / 2000SC
Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / 1000 1SC / 1000 2SC / 1250SC / 1600SC / 1800SC / 2000SC Project name: Customer: Address, location of the system: Serial number
More informationElectronic Diesel Control EDC 16
Service. Self-Study Programme 304 Electronic Diesel Control EDC 16 Design and Function The new EDC 16 engine management system from Bosch has its debut in the V10-TDI- and R5-TDI-engines. Increasing demands
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More informationVolkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
More informationTHERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
More informationInstructions & Safety Information Models A220-20D and A220-20L Version 2
Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057
More informationFault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1
Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault
More informationCTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual
CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual Goodway Technologies Corporation 420 West Avenue Stamford, CT 06902-6384 (203)359-4708 Sales: 1-800-333-7467 Customer Service: 1-800-370-2855
More informationCompressor Service & Maintenance Manual
Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance
More informationThe table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
More informationThe cylinder head bolts tightening stages have been updated as listed in Table 1.
NUMBER: 07 EPA04 MBE 4000-6 S.M. REF.: 1.2.2 ENGINE: MBE 4000 DATE: November 2007 SUBJECT: CYLINDER HEAD BOLTS TIGHTENING STAGES PUBLICATION: 6SE412 The cylinder head bolts tightening stages have been
More information