SMITH DESIGN GROUP, INC.

Size: px
Start display at page:

Download "SMITH DESIGN GROUP, INC."

Transcription

1 SMITH DESIGN GROUP, INC. ARCHITECTURE CONSTRUCTION PLANNING PROJECT: Addition to Mobis ARCHITECT PROJECT NO.: #1311 ` on Mitchell Young Road TO: City of Montgomery DATE: 9/11/2013 Building Department 25 Washington Ave. First Floor Montgomery, AL REFERENCE: #13171 ATTN: Jerry Russell, Building Official TRANSMITTING: SUBMITTED FOR: ACTION TAKEN: Shop Drawings Change Order For pricing Approved as submitted Prints Pay Request For approval Exceptions taken x Letter/Copy Invoice For payment No exceptions taken Specifications Construction Documents Per your request Re-submit Samples/Brochures X Other: For review COPIES DATE DESCRIPTION One 6-Sep-13 City of Montgomery Plan Review Letter dated September 6, 2013 Reference #13084 One 11-Sep-13 Letter of Compliance from Smith Design Group, Inc. dated September 11, 2013 REMARKS: Mr. Russell, Please accept the attached letter of compliance dated Sept. 11, 2013 with responses to all the comments from your Sept. 6, 2013 letter. Also ComCheck and revised drawings are attached. With regards, Gordon M. "Skip" Smith, Jr. CC: File SMITH DESIGN GROUP, INC. VIA: Gordon "Skip" M. Smith, Jr., AIA 307 Church Street Suite B LaGrange, Georgia TEL FAX

2 MOBIS ADDITION LETTER MITCHELL YOUNG ROAD REF. # SEPTEMBER 9, 2013 SMITH DESIGN GROUP 1. Handicap requirements to comply with IBC Chapter 11 and ICC/ANSI All design work for the addition has been performed with the utmost care to comply with accessibility requirements of IBC and ADAAG(ICC/ANSI all ). Please refer to architectural drawings and details. 2. Fire barriers to comply with IBC 706. Note: Two hour separation of break room required. Plans do not comply. See IBC Table Please see attached revised architectural plans showing two hour separation of break room per IBC 2003 table Penetrations of fire rated assemblies to be firestopped per IBC 712. Provide copies of all firestopping submittals to the inspectors showing all systems to be installed. Will comply. Firestopping submittals for all penetrations of fire rated assemblies will be submitted to Building Official by the Building contractor, prior to installation of firestopping 4. Maintain required means of egress during construction per IBC The building contract and owner will maintain required means of egress at all times during construction, demolitions, and additions to the existing facilities per IBC Submit information showing compliance with State Energy Code. Please see attached ComCheck- Energy Code compliance Certificate signed by Design Professionals.

3 6. Certification of compliance with State Energy Code to be provided by design professional prior to certificate of occupancy being issued. Please see attached ComCheck- Energy Code compliance Certificate signed by Design Professionals. See E-1.2, revise canopy light spec. (60W->42W) to meet ComCheck. See M-2.1 revised RTU-38 EER(11.0) to meet ComCheck. 7. Provide exterior emergency lighting in exit court area and for travel along exterior exit stair. See E-6.1 Exterior Emergency Lighting (X2) were provided. 8. Smoke and heat vents are required per IBC Activation to comply with Montgomery Fire Department requirements. See attached revised drawings A-012 showing smoke and heat vents per IBC 2003, Activation to comply with Montgomery Fire Department Requirements. 9. Women s restroom vent riser has the following violations: a. First Water Closet downstream of all fixtures. See P-2 & P-4, relocated vent stack to the first water closet. b. Water closet located on floor drain line is required to be vented. See P-2 & P-4, provided vent for water closet and floor drain. 10. Equipment supplied by an electrical feeder or branch circuit will bear the stamp of approval from a nationally recognized testing laboratory or be certified by a State of Alabama registered electrical engineer. The engineer must use a recognized standard for completing a third party field evaluation. This includes large and small equipment installed as a unit. See E-7.1 Added General Notes 11. Existing and new service equipment for this building will conform to (and not limited to) NEC 230.2, NEC and NEC See E-7.1 Added General Notes 12. Equipment grounding conductors shall be sized by NEC All grounding conductors were sized by NEC

4 Fire Department Inspections Requirements per NFPA 1 (Uniform Fire Code) and NFPA 101 (Life Safety Code) and NFPA 5000 (Building Construction and Safety Code) 2012 editions by the Montgomery Fire Rescue, Division of Inspections. 1. Fire Department Access and Roads shall be provided and/or maintained in accordance with NFPA 1 Section The Building Contractor will provide and maintain Fire Department Access Roads in accordance with NFPA 1 Section 18.2 during and after construction 2. Floor level on both sides of doors in the means of egress shall comply with NFPA 101, section Elevation of floor surfaces on both side of a door in a means of egress will be maintained level within 13mm (1/2 ) 3. Existing exits to be maintained during construction The Building Contractor and owner will maintain existing exits at all times during construction, demolition, and additions to the existing facilities. 4. Fire alarm to comply with NFPA 72 See Sheet FA-1, added note. 5. Sprinkler system to comply with NFPA 13. Plans to be submitted to the Fire Departments New Construction Division for review, approval and permitting. Detailed shop drawings and calculations will be provided to the Fire Department New Construction Division by the Sprinkler Subcontractor who will design and install the sprinkler system per NFPA 13.

5 Generated by COMcheck-Web Software Envelope Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: Addition Project Title : MOBIS ALABAMA EXPANSION FOR IP SHOP Construction Site: Owner/Agent: Designer/Contractor: 1395 Mitchell Young Road Montgomery, AL Section 2: General Information Building Location (for weather data): Climate Zone: Building Space Conditioning Type(s): Montgomery, Alabama 3a Nonresidential Building Type Floor Area Manufacturing Facility Manufacturing Facility 5740 Section 3: Envelope Assemblies Envelope PASSES: Design 3% better than code. Climate-Specific Requirements: Component Name/Description Gross Area or Perimeter Cavity R-Value Cont. R-Value Proposed U-Factor Budget U-Factor(a) Roof: Insulation Entirely Above Deck Ext. Wall: Metal Building Wall Door: Insulated Metal, Swinging Door: Insulated Metal, Non-Swinging Floor: Unheated Slab-On-Grade (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 90.1 (2007) Standard requirements in COMcheck-Web and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Project Title: MOBIS ALABAMA EXPANSION FOR IP SHOP Report date: 09/06/13 Data filename: Page 1 of 1

6 90.1 (2007) Standard Section 1: Project Information COMcheck Software Version Interior Lighting and Power Compliance Certificate Project Type: Addition Project Title : MOBIS ALABAMA EXPANSION FOR IP SHOP Construction Site: Owner/Agent: Designer/Contractor: 1395 Mitchell Young Road Montgomery, AL Section 2: Interior Lighting and Power Calculation A B Floor Area C Allowed Watts / ft2 D Allowed Watts Manufacturing Facility Manufacturing Facility Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Total Allowed Watts = B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) Manufacturing Facility (37272 sq.ft.) Linear Fluorescent 1: 46" T5 54W / Electronic Manufacturing Facility (5740 sq.ft.) Linear Fluorescent 2: 48" T8 32W / Electronic Linear Fluorescent 3: 46" T5 54W / Electronic Linear Fluorescent 4: 48" T8 32W / Electronic Linear Fluorescent 5: 24" T8 17W / Electronic Section 4: Requirements Checklist Lighting Wattage: 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies YES 2. Exit signs 5 Watts or less per sign. Controls, Switching, and Wiring: Total Proposed Watts = Independent manual or occupancy sensing controls for each space (remote switch with indicator allowed for safety or security). 4. Occupant sensing control in class rooms, conference/meeting rooms, and employee lunch and break rooms. Exceptions: Spaces with multi-scene control; shop classrooms, laboratory classrooms, and preschool through 12th grade classrooms. 5. Automatic shutoff control for lighting in >5000 sq.ft buildings by time-of-day device, occupant sensor, or other automatic control. Exceptions: Project Title: MOBIS ALABAMA EXPANSION FOR IP SHOP Report date: 09/05/13 Data filename: Untitled.cck Page 1 of 6

7 24 hour operation lighting; patient care areas; where auto shutoff would endanger safety or security. 6. Master switch at entry to hotel/motel guest room. 7. Separate control device for display/accent lighting, case lighting, task lighting, nonvisual lighting, lighting for sale, and demonstration lighting. 8. Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts). Exceptions: Electronic high-frequency ballasts. Luminaires not on same switch. Recessed luminaires 10 ft. apart or surface/pendant not continuous. Luminaires on emergency circuits. Voltage Drop: 9. Feeder conductors have been designed for a maximum voltage drop of 2 percent. 10.Branch circuit conductors have been designed for a maximum voltage drop of 3 percent. Interior Lighting PASSES: Design 49% better than code. Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Section 5: Post Construction Compliance Statement Record Drawings and Operating and Maintenance Manuals: 1. Construction documents with record drawings and operating and maintenance manuals provided to the owner. Lighting Designer or Contractor Name Signature Date Project Title: MOBIS ALABAMA EXPANSION FOR IP SHOP Report date: 09/05/13 Data filename: Untitled.cck Page 2 of 6

8 COMcheck Software Version Mechanical Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: Addition Project Title : MOBIS ALABAMA EXPANSION FOR IP SHOP Construction Site: Owner/Agent: Designer/Contractor: 1395 Mitchell Young Road Montgomery, AL Section 2: General Information Building Location (for weather data): Climate Zone: Montgomery, Alabama 3a Section 3: Mechanical Systems List Quantity System Type & Description 1 HVAC System 1 (Single Zone) : Rooftop Packaged Heat Pump Heating Mode: Capacity = 250 kbtu/h, Efficiency = 7.70 COP Cooling Mode: Capacity = 304 kbtu/h, Efficiency = 9.70 EER 1 HVAC System 2 (Single Zone) : Rooftop Packaged Heat Pump Heating Mode: Capacity = 250 kbtu/h, Efficiency = 7.70 COP Cooling Mode: Capacity = 304 kbtu/h, Efficiency = 9.70 EER 1 HVAC System 3 (Single Zone) : Rooftop Packaged Heat Pump Heating Mode: Capacity = 250 kbtu/h, Efficiency = 7.70 COP Cooling Mode: Capacity = 304 kbtu/h, Efficiency = 9.70 EER 1 HVAC System 4 (Single Zone) : Rooftop Packaged Heat Pump Heating Mode: Capacity = 250 kbtu/h, Efficiency = 7.70 COP Cooling Mode: Capacity = 304 kbtu/h, Efficiency = 9.70 EER 1 HVAC System 5 (Single Zone) : Rooftop Packaged Heat Pump Heating Mode: Capacity = 250 kbtu/h, Efficiency = 7.70 COP Cooling Mode: Capacity = 184 kbtu/h, Efficiency = EER Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : 1. Equipment minimum efficiency: Heat Pump: 3.20 COP 9.50 EER (9.2 IPLV) 2. Heat pump thermostat required when supplemental electric resistance heat is installed 3. VAV fans with static pressure sensors are placed in a position such that the controller setpoint is no greater than one-third the total design fan static pressure. If placement results in the sensor being located downstream of major duct splits, multiple sensors are installed in each major branch. Systems with DDC of individual zone boxes reporting to the central control panel and reset of static pressure setpoint based on the zone requiring the most pressure. 4. Systems with DDC of individual zone boxes reporting to the central control panel has static pressure setpoint reset based on the zone requiring the most pressure. Requirements Specific To: HVAC System 2 : 1. Equipment minimum efficiency: Heat Pump: 3.20 COP 9.50 EER (9.2 IPLV) 2. Heat pump thermostat required when supplemental electric resistance heat is installed 3. VAV fans with static pressure sensors are placed in a position such that the controller setpoint is no greater than one-third the total design fan static pressure. If placement results in the sensor being located downstream of major duct splits, multiple sensors are installed in each major branch. Project Title: MOBIS ALABAMA EXPANSION FOR IP SHOP Report date: 09/05/13 Data filename: Untitled.cck Page 3 of 6

9 Systems with DDC of individual zone boxes reporting to the central control panel and reset of static pressure setpoint based on the zone requiring the most pressure. 4. Systems with DDC of individual zone boxes reporting to the central control panel has static pressure setpoint reset based on the zone requiring the most pressure. Requirements Specific To: HVAC System 3 : 1. Equipment minimum efficiency: Heat Pump: 3.20 COP 9.50 EER (9.2 IPLV) 2. Heat pump thermostat required when supplemental electric resistance heat is installed 3. VAV fans with static pressure sensors are placed in a position such that the controller setpoint is no greater than one-third the total design fan static pressure. If placement results in the sensor being located downstream of major duct splits, multiple sensors are installed in each major branch. Systems with DDC of individual zone boxes reporting to the central control panel and reset of static pressure setpoint based on the zone requiring the most pressure. 4. Systems with DDC of individual zone boxes reporting to the central control panel has static pressure setpoint reset based on the zone requiring the most pressure. Requirements Specific To: HVAC System 4 : 1. Equipment minimum efficiency: Heat Pump: 3.20 COP 9.50 EER (9.2 IPLV) 2. Heat pump thermostat required when supplemental electric resistance heat is installed 3. VAV fans with static pressure sensors are placed in a position such that the controller setpoint is no greater than one-third the total design fan static pressure. If placement results in the sensor being located downstream of major duct splits, multiple sensors are installed in each major branch. Systems with DDC of individual zone boxes reporting to the central control panel and reset of static pressure setpoint based on the zone requiring the most pressure. 4. Systems with DDC of individual zone boxes reporting to the central control panel has static pressure setpoint reset based on the zone requiring the most pressure. Requirements Specific To: HVAC System 5 : 1. Equipment minimum efficiency: Heat Pump: 3.20 COP EER 2. Heat pump thermostat required when supplemental electric resistance heat is installed 3. VAV fans with static pressure sensors are placed in a position such that the controller setpoint is no greater than one-third the total design fan static pressure. If placement results in the sensor being located downstream of major duct splits, multiple sensors are installed in each major branch. Systems with DDC of individual zone boxes reporting to the central control panel and reset of static pressure setpoint based on the zone requiring the most pressure. 4. Systems with DDC of individual zone boxes reporting to the central control panel has static pressure setpoint reset based on the zone requiring the most pressure. Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Automatic Controls: Setback to 55 F (heat) and 85 F (cool); 7-day clock, 2-hour occupant override, 10-hour backup Continuously operating zones 2. Hot water pipe insulation: 1 in. for pipes <=1.5 in. and 2 in. for pipes >1.5 in. Chilled water/refrigerant/brine pipe insulation: 1 in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes <=1.5 in. and 3 in. for pipes >1.5 in. Piping within HVAC equipment. Fluid temperatures between 60 and 105 F. Fluid not heated or cooled. Runouts <4 ft in length. Pipe unions in heating systems. 3. Load calculations per acceptable engineering standards and handbooks 4. Thermostatic controls have 5 F deadband Thermostats requiring manual changeover between heating and cooling Special occupancy or special applications where wide temperature ranges are not acceptable and are approved by the authority having jurisdiction. 5. Demand control ventilation (DCV) present for high design occupancy areas (>40 person/1000 ft2 in spaces >500 ft2) and served by systems with any one of 1) an air-side economizer, 2) automatic modulating control of the outdoor air damper, or 3) a design outdoor airflow greater than 3000 cfm. Project Title: MOBIS ALABAMA EXPANSION FOR IP SHOP Report date: 09/05/13 Data filename: Untitled.cck Page 4 of 6

10 Systems with heat recovery. Multiple-zone systems without DDC of individual zones communicating with a central control panel. Systems with a design outdoor airflow less than 1200 cfm. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 6. Where separate thermostats are used for heating and cooling, acceptable measures are used to prevent simultaneous heating and cooling 7. Stair and elevator shaft vents are equipped with motorized dampers Ventilation systems serving unconditioned spaces. Gravity (non-motorized) dampers are acceptable in buildings less than three stories in height above grade. 8. Acceptable measures used to prevent simultaneous humidification and dehumidification Desiccant systems and systems for uses requiring specific humidity levels (approval required) 9. Automatic controls for freeze protection systems present 10.Duct, plenum, and piping insulation surfaces suitably protected from weather, moisture, or likely damage 11.Duct Sealing: a) Pressure sensitive tape used as the primary sealant is certified to comply with UL-181A or UL-181B, b) longitudinal and transverse seams for ducts in unconditioned spaces, c) longitudinal and transverse seams and duct wall penetrations for ducts outside the building, d) transverse seams on buried ducts 12.Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings Gravity dampers acceptable in buildings <3 stories Gravity dampers acceptable in systems with outside or exhaust air flow rates less than 300 cfm where dampers are interlocked with fan 13.R-6 for supply air ducts located outside the building, in ventilated attics and in unvented attic above insulated ceiling R-3.5 for supply air ducts in unvented attic with roof insulation, unconditioned and underground spaces R-3.5 for return air ducts located outside the building, in ventilated attics and in unvented attic above insulated ceiling 14.Humidistat controls prevent reheating, recooling, and mixing of mechanically heated air with mechanically cooled air Capability of first reducing supply air volume 50% or less of the design rate or minimum outdoor air ventilation, or per regulatory standard, whichever is larger, before combined heating/cooling occurs. Cooling capacity <80 kbtu/h and capability to unload cooling equipment. Cooling capacity <40 kbtu/h. Rigid humidity requirements. Site-recovered or site-solar energy sources or. Use of a desiccant systems. 15.Kitchen hoods >5,000 cfm provided with 50% makeup air that is uncooled and heated to no more than 60 F unless specifically exempted Where hoods are used to exhaust ventilation air that would otherwise exfiltrate or be exhausted by other fan systems. Certified grease extractor hoods that require a face velocity no >60 fpm. 16.Buildings with fume hood systems having an exhaust rate > 15,000 cfm has at least one of the following features: a) VAV hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. b) Direct makeup air supply equal to at least 75% of the exhaust rate, heated no warmer than 2 F below room setpoint, cooled to no cooler than 3 F above room setpoint, no humidification added, and no simultaneous heating and cooling used for dehumidification control. c) Heat recovery systems to precondition makeup air from fume hood exhaust. 17.Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70% outside air fraction or specifically exempted. Laboratory fume hood systems with a total exhaust rate <= 5000 cfm. Systems serving spaces that are not cooled and heated to <60 F. Systems with more than 60% of the outdoor heating energy is provided from site-recovered or site solar energy. Systems exhausting toxic, flammable, paint, or corrosive fumes or dust. Commercial kitchen hoods. Systems requiring dehumidification with cooling coil energy recovery in series with the cooling coil. Where the largest exhaust source is less than 75% of the design outdoor airflow. Project Title: MOBIS ALABAMA EXPANSION FOR IP SHOP Report date: 09/05/13 Data filename: Untitled.cck Page 5 of 6

11 Heating energy recovery. Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Section 6: Post Construction Compliance Statement HVAC record drawings of the actual installation and performance data for each equipment provided to the owner within 90 days after system acceptance. HVAC O&M documents for all mechanical equipment and system provided to the owner within 90 days after system acceptance. Written HVAC balancing report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer-Name Signature Date Project Title: MOBIS ALABAMA EXPANSION FOR IP SHOP Report date: 09/05/13 Data filename: Untitled.cck Page 6 of 6

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

HVAC Simplified Approach Option

HVAC Simplified Approach Option HVAC Simplified Approach Option Part I Project Address: City: HVAC System Designer of Record: Date: Zip: Qualification The building is 2 stories or less in height and has a gross floor area is less than

More information

COMMERCIAL. Compliance. What s in it FOR ME? DOE s Building Energy Codes Program

COMMERCIAL. Compliance. What s in it FOR ME? DOE s Building Energy Codes Program COMMERCIAL Compliance DOE s Building Energy Codes Program (www.energycodes.gov) and ICC (www.iccsafe.org) offer many resources for commercial code officials. Examples in this section include: What s in

More information

Florida Energy Efficiency Code For Building Construction

Florida Energy Efficiency Code For Building Construction Florida Energy iciency Code For Building Construction EnergyGauge Summit Fla/Com-2010, ective Date: March 15, 2012 -- Form 506-2010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY

More information

Building Permit Application

Building Permit Application Building Permit Application Administrative Use Only PARENT PERMIT NUMBER (Required if part of another project) PERMITTEE: PERMITTEE ADDRESS: E-MAIL ADDRESS: ARCHITECT/ENGINEER: PHONE: PHONE: ARCHITECT/ENGINEER

More information

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained). CITY OF MILPITAS Building & Safety Department 455 E. Calaveras Blvd. Milpitas, CA 95035 408-586-3240 www.ci.milpitas.ca.gov RESIDENTIAL AIR CONDITIONING, REPLACEMENT 1. PERMIT INFORMATION: The replacement

More information

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist #506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist Case #: Date: Project Name: Site Address: Application Submittal Building permit applications and plans can be submitted to the

More information

APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1

APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1 APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = The lower the Energy Performance Index, the more efficient

More information

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings SUCCESS WITH 2012 IECC DELAWARE Recommended Practices for Optimized Energy Savings for Builders & Trades COPYRIGHT 2015 ADVANCED ENERGY. ALL RIGHTS RESERVED VERSION 2015.1.0 CHECKLIST: JOB READY 1. 2.

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

What triggers the Energy Code (Title 24, part 6)?

What triggers the Energy Code (Title 24, part 6)? Title 24 Standards Essentials What triggers the Energy Code (Title 24, part 6)? Jon McHugh McHugh Energy Consultants Inc. April 2014 This program is funded by California utility customers under the auspices

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades Success with 2015 IECC Northeast & Mid-Atlantic Checklist for Builders & Trades COPYRIGHT 2015 ADVANCED ENERGY. ALL RIGHTS RESERVED TEMPLATE 2015.1.0 PAGE 1 CHECKLIST: JOB READY 1. 2. 3. 4. 5. 6. 7. 8.

More information

SAM HOUSTON STATE UNIVERSITY

SAM HOUSTON STATE UNIVERSITY PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the

More information

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW PRELIMINARY BUILDING REVIEW two sets of the following: Architectural/engineering design development drawings indicating size of the building,

More information

IECC Compliance Guide for Homes in Virginia

IECC Compliance Guide for Homes in Virginia IECC Compliance Guide for Homes in Virginia Amended Version of 2012 International Energy Conservation Code July 14, 2014 Climate Zone Since the entire state of Virginia falls in the IECC Climate Zone 4,

More information

ENHANCED LABORATORY HVAC SYSTEM

ENHANCED LABORATORY HVAC SYSTEM ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of

More information

2011 Energy Efficiency Expo!

2011 Energy Efficiency Expo! Welcome to the 2011 Energy Efficiency Expo! Thank you to our session sponsors! Comparison Between the 2009 and 2012 International Energy Conservation Code What s coming when the new commercial energy code

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

Basics of HVAC Cleaning

Basics of HVAC Cleaning Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project

More information

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

2015 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

2015 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY MINNESOTA ENERGY CODE COMPLIANCE COLLABORATIVE 2015 Minnesota Residential Energy Code (MR 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY (July 15, 2015 Update) Note: The following information contains

More information

Center for Energy Education Laboratory

Center for Energy Education Laboratory Paper ID #7072 Center for Energy Education Laboratory Dr. Robert Gilbert, Sinclair Community College Robert B. Gilbert, Ph.D., LEED AP, BA, is an Associate Professor of Energy Management Technology, and

More information

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may

More information

HVAC Systems in Schools & Commercial Buildings and Radon

HVAC Systems in Schools & Commercial Buildings and Radon HVAC Systems in Schools & Commercial Buildings and Radon References US EPA Radon Prevention in the Design and Construction of Schools and Other Large Buildings http://www.epa.gov/ordntrnt/ord/nrmrl/pubs/1993/air/

More information

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT Presentation Synopsis Heating, Ventilating and Air Conditioning Building Condition Assessment Vancouver, B.C. Prepared for: EPIC Prepared by: Douglas Spratt, P.Eng Douglas Spratt & Associates Ltd. www.dspratt-associates.com

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

Commercial Building Permit Application & Submittal Guidelines

Commercial Building Permit Application & Submittal Guidelines Building Inspection Department 1625 13 th Street, Suite 106 Lubbock, Texas 79457 (806) 775-2087 (806) 775-2088 http://buildinsp.ci.lubbock.tx.us/ Commercial Building Permit Application & Submittal Guidelines

More information

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems

More information

AIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM

CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM CITY PLAN REVIEW AND INSPECTION Lisa Fleming Brown, CPM Houston Commercial Energy Conservation Code (2011) A choice of 2009 IECC or ASHRAE 90.1-2007 with amendments. Effective September 2, 2011. Complete

More information

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same

More information

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION PERMITS AND INSPECTIONS FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION 911 Assigned PROJECT LOCATION Subdivision: Lot: Blk: Sec: PROJECT New Construction Addition/Remodel Demolition Other: Number

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,

More information

SECTION 15950 - TESTING, ADJUSTING, AND BALANCING

SECTION 15950 - TESTING, ADJUSTING, AND BALANCING SECTION 15950 - TESTING, ADJUSTING, AND BALANCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Commissioning - Construction Documents (Page 1 of 6)

Commissioning - Construction Documents (Page 1 of 6) Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem

More information

City of St. Charles Basement Finish or Remodel

City of St. Charles Basement Finish or Remodel City of St. Charles Basement Finish or Remodel Building & Code Enforcement Division 2 East Main Street St. Charles IL 60174 630.377.4406 (Office) 630.443.4638 (Fax) http://www.stcharlesil.gov Please direct

More information

1 RCNY 5000-01 CHAPTER 5000. New York City Energy Conservation Code

1 RCNY 5000-01 CHAPTER 5000. New York City Energy Conservation Code 1 RCNY 5000-01 CHAPTER 5000 New York City Energy Conservation Code 5000-01 Construction document approval requirements for compliance with the New York City Energy Conservation Code. (a) Purpose. This

More information

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing

More information

Mechanical, Plumbing, and Fire Protection Conditions

Mechanical, Plumbing, and Fire Protection Conditions Mechanical, Plumbing, and Fire Protection Conditions Mechanical Conditions The mechanical systems within the building consist of a combination of the original 1926 systems and renovations that occurred

More information

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP research journal 2013 / VOL 05.01 www.perkinswill.com SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP ARCHITECTURE AND ENGINEERING OF SUSTAINABLE BUILDINGS Current Trends in Low-Energy HVAC Design

More information

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis Components HVAC General System Selection Life Cycle Cost Analysis Outdoor Air Design Values Indoor Air Design Values Outdoor Air Ventilation Welding Ventilation Temperature Control Systems Ductwork HVAC

More information

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

Variable Air Volume - VAV

Variable Air Volume - VAV Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:

More information

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application February 2014 Code Requirements and Inspections in Educational Occupancies Presented By: Barry W. Rickert Douglas M. Schanne Fire Marshal Training Program Supervisor Office of Education & Data Management

More information

Riverside City College. Math & Science Building HVAC Investigation. May 23, 2013

Riverside City College. Math & Science Building HVAC Investigation. May 23, 2013 May 23, 2013 Prepared by: P2S Engineering, Inc. 5000 East Spring St, Eighth Floor Long Beach, CA 90815 T 562.497.2999 F 562.497.2990 www.p2seng.com Table of Contents Executive Summary... 2 Background...

More information

Flexibility, Efficiency In San Antonio Arena

Flexibility, Efficiency In San Antonio Arena 2005, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Reprinted by permission from ASHRAE Journal, (Vol. 47, No. 9, September 2005). This article may not

More information

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects Makeup Air For Exhaust Systems In Tight Houses Tony Jellen Engineering Projects PA Housing & Land Development Conference February 23, 2012 Effects of Kitchen Ventilation on Residential Dwellings Anthony

More information

for Plans Examiners and Building Inspectors

for Plans Examiners and Building Inspectors Building Technologies Program HVAC Controls Guide for Plans Examiners and Building Inspectors September 2011 Authors: Eric Makela, PNNL James Russell, PECI Sarah Fujita, PECI Cindy Strecker, PECI Prepared

More information

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY 12839 (518) 747-5426 /

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY 12839 (518) 747-5426 / John E. Barton Mayor Ellen M. Brayman Clerk/Treasurer VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY 12839 (518) 747-5426 / Trustees: James Gallagher Robert Cook Michael Horrigan Thomas VanAernem

More information

PLAN SUBMITTAL INFORMATION

PLAN SUBMITTAL INFORMATION PLAN SUBMITTAL INFORMATION APPLICATION FOR A BUILDING PERMIT Prior to drafting construction drawings, please check with the North Miami Beach Community Development Department concerning the following:

More information

COMMISSIONING OF HVAC SYSTEMS

COMMISSIONING OF HVAC SYSTEMS FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS

More information

BUILDING PERMIT SPECIFICATIONS

BUILDING PERMIT SPECIFICATIONS BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide

More information

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...

More information

24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by 24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL ENERGY CONSERVATION CODE (1) The Department of Labor and Industry adopts and incorporates by reference the International Code Council's International

More information

HVAC Checklist - Long Form

HVAC Checklist - Long Form HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,

More information

Appendix B. 2010 Florida Building Code Building Section 423.25 Public Shelter Design Criteria

Appendix B. 2010 Florida Building Code Building Section 423.25 Public Shelter Design Criteria Appendix B 2010 Florida Building Code Building Section 423.25 Public Shelter Design Criteria 423.25 Public shelter design criteria. 423.25.1 New facilities. New educational facilities for school boards

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted

More information

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13 presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Who is the AFSA? Safe and Secure Alberta Fire Safety Association Fire industry members working together to improve

More information

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION

More information

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 Office of the Fire Marshal 1.0 PERMITS FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 1.1 To acquire an installation

More information

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS 01. SAFETY INSPECTION of service equipment at FPL Power Source 02. Construction GFI power outlets (Temp Pole for Construction) 03. 90 day temporary power

More information

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers City of Duluth Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers Thank you for taking the time to join us today. We know you are busy and your time is valuable.

More information

2012 BIM Guidelines and Standards (Rev. 00) University at Albany

2012 BIM Guidelines and Standards (Rev. 00) University at Albany A. Building Information Modeling (BIM) Guidelines: The Office of AECM will require the submission of BIM modeling files as part of an electronic file submission to the AECM project manager as requested

More information

WHEN IS A PERMIT REQUIRED?

WHEN IS A PERMIT REQUIRED? WHEN IS A PERMIT REQUIRED? Any owner, builder, contractor, or other authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure,

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used by

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

2014 Limited Plan Submittal Checklist

2014 Limited Plan Submittal Checklist City of Aurora Public Works Department WET AND DRY CHEMICAL HOOD SUPPRESSION SYSTEM 2014 Limited Plan Submittal Checklist Building Division 15151 E. Alameda Parkway, Ste 2400 Aurora, CO 80012 303-739-7420

More information

INDIANA COMMERCAL ENERGY CODE BASELINE STUDY

INDIANA COMMERCAL ENERGY CODE BASELINE STUDY INDIANA COMMERCAL ENERGY CODE BASELINE STUDY March 21, 2005 Report Prepared for Indiana Department of Commerce, Energy and Recycling Division One North Capitol Avenue, Suite 700 Indianapolis, IN 46204

More information

Red River College MECB 101 School of Construction and Engineering Technologies Manitoba Energy Code for Buildings 101 (MECB 101)

Red River College MECB 101 School of Construction and Engineering Technologies Manitoba Energy Code for Buildings 101 (MECB 101) Manitoba Energy Code for Buildings 101 (MECB 101) The National Research Council of Canada (NRC) has issued the National Energy Code for Buildings (NECB) in 2011. The main objective of NECB 2011 was to

More information

BUILDING SAFETY UNIT

BUILDING SAFETY UNIT POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential

More information

Aurora Mall. Aurora (Denver), Colorado

Aurora Mall. Aurora (Denver), Colorado is the largest superregional mall in the city of Aurora, and it s only getting bigger and better. The mall is currently undergoing a significant interior and exterior renovation, scheduled for completion

More information

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc. LIFE SAFETY UPDATE FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc. The purpose of this update is as follows: Remind all state

More information

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB

More information

NYC Department of Education Building Condition Assessment Survey 2014-2015 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

NYC Department of Education Building Condition Assessment Survey 2014-2015 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004 School: InspectionId Asset Data Inspection Type Building Assessment Survey 204-205 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 0004 Time In Last Edited 255 MECHANICAL 205-05-8 09:00AM

More information

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES Department of Health and Human Services, Division of Public Health Occupational and Environmental Epidemiology Branch 1912 Mail Service Center, Raleigh, North Carolina 27699-1912 BUILDING ASSESSMENT QUESTIONNAIRE

More information

Energy Efficiency in Industrial HVAC Systems

Energy Efficiency in Industrial HVAC Systems Energy Efficiency in Industrial HVAC Systems Heating, ventilation and air conditioning (HVAC) constitutes up to 35 percent of energy used in manufacturing facilities. This fact sheet is geared towards

More information

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming

More information

CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov

CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.

More information

Australian/New Zealand Standard

Australian/New Zealand Standard Australian/New Zealand Standard The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings UPDATED AS/NZS 1668.1:2015 What is the scope of this Standard? The

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1

More information

2013 BUILDING ENERGY EFFICIENCY STANDARDS

2013 BUILDING ENERGY EFFICIENCY STANDARDS 2013 BUILDING ENERGY EFFICIENCY STANDARDS Title 24, Part 6, and Associated Administrative Regulations in Part 1 CALIFORNIA ENERGY COMMISSION Edmund G. Brown Jr., Governor MAY 2012 CEC 400 2012 004 CMF

More information

Certification: Building Plans Examiner. Exam ID: B3

Certification: Building Plans Examiner. Exam ID: B3 Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building

More information

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715, 4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.

More information

Design and Construction Design Phase Deliverables

Design and Construction Design Phase Deliverables Design and Construction Design Phase Deliverables Notes: 1. The Architect or Engineer of record shall submit this document along with the deliverables for the project at the end of each design phase for

More information

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal. 2.02 DESIGN DEVELOPMENT PHASE GENERAL The Architect shall prepare the Design Development Documents from the approved Schematic Design. The Design Development Documents shall consist of drawings and other

More information

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA.

RFI Response RFP: HSCG88-16-R-PQQ015 Replace HVAC Bldg A & C San Diego, CA. 1. There is verbiage in the hazardous material report referring to a state licensed abatement contractor. Within the recommendations part of the report (page 64 of 111 of the specification pdf) is the

More information

Mechanical Technical Assignment One ASHRAE Standard 62.1 and Standard 90.1 Evaluation

Mechanical Technical Assignment One ASHRAE Standard 62.1 and Standard 90.1 Evaluation Mechanical Technical Assignment One ASHRAE Standard 62.1 and Standard 90.1 Evaluation Prepared for: Dr. James D. Freihaut Department of Architectural Engineering The Pennsylvania State University Prepared

More information

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible

More information

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen May 2008 Wisconsin Area PO BOX 115 Lake Geneva, WI 53147 CELL (414) 550-4765 Home Performance with ENERGY STAR Evaluation Report Customer

More information

SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK

SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK 1 GENERAL 1.1 GENERAL REQUIREMENTS A. This Section is coordinated with and complementary to the General Conditions and Supplementary General Conditions

More information

Acoustical Design Guidelines for HVAC Systems in Schools

Acoustical Design Guidelines for HVAC Systems in Schools Acoustical Design Guidelines for HVAC Systems in Schools Seminar 9, ASHRAE Summer Meeting Albuquerque, New Mexico Sponsor: TC 2.6 Sound and Vibration Robert M. Lilkendey Associate Principal Consultant

More information