Contents. I. Dantherm Product Index II. Understanding Dantherm Model Identification... 4

Size: px
Start display at page:

Download "Contents. I. Dantherm Product Index II. Understanding Dantherm Model Identification... 4"

Transcription

1 Closed-Loop Cooling for Electronics & Communications Enclosures

2 Contents I. Dantherm Product Index... 3 II. Understanding Dantherm Model Identification... 4 III. Classic Series Air-Conditioners Classic 20 Air-conditioner 2,000 BTU / Hr Classic 30 Air-conditioner 4,000 BTU / Hr Classic 30 Air-conditioner 7,500 BTU / Hr Classic 47 Air-conditioner 10,000 BTU / Hr Classic 50 Air-conditioner 12,500 BTU / Hr Classic 50 Air-conditioner 13,000 BTU / Hr Classic 53 Air-conditioner 19,000 BTU / Hr Classic Top-Mount Air-Conditioners Class 1 Div 1 Hazardous Duty Air-Conditioner IV. Pinnacle Series Air-to-Air Heat Exchangers 23 Pinnacle Heat Exchanger 11 W / o F Pinnacle Heat Exchanger 15 W / o F Pinnacle Heat Exchanger 35 W / o F Pinnacle Heat Exchanger 45 W / o F Pinnacle Heat Exchanger 55 W / o F Pinnacle Heat Exchanger 100 W / o F V. Custom Products and Design Capabilities VI. Dantherm Technologies and Innovations & Summary Focus. Trust. Initiative. 2

3 Dantherm Standard Product Index Classic Series Air-Conditioners Product Model # Performance Voltages Refrigerant Classic 20 CS ,000 BTU / Hr A, B5, B6 134a Classic 30 CS ,000 BTU / Hr A, B 134a Classic 30 Classic 47 CS (previously CS030060) CS (previously CS047120) 7,500 BTU / Hr A, B5, B6 R-22 10,000 BTU / Hr B R-22 Classic 50 CS ,500 BTU / Hr B R-22 Classic 50 CS ,000 BTU / Hr B R-22 Classic 53 CS ,000 BTU / Hr B 134a Rack/Top Mount CS ,500 BTU / Hr A, B 134a Rack/Top Mount CS ,500 BTU / Hr A, B R-22 A = 115V 1 Ph 50/60 Hz B = 208/ 230V 1 Ph 50/60 Hz B5 = 230V 1 Ph 50 Hz B6 = 230V 1 Ph 60 Hz Pinnacle Series Heat Exchangers Product Model # Performance Voltages Refrigerant 23" Pinnacle PS W / o F A, B, Z N/A Pinnacle 2" PS W / o F A, B, Z N/A Pinnacle 6" PS W / o F A, B, Z N/A Pinnacle 6" PS W / o F A, B, Z N/A Pinnacle 8" PS W / o F A, B, Z N/A 60" Pinnacle PS W / o F B N/A A = 115V 1 Ph 50/60 Hz B = Z = 230V 1 Ph 50/60 Hz 48V DC 3

4 Understanding Dantherm Model Identification Dantherm Classic Series Air-Conditioners C=Classic S= Standard Configuration X= Custom Configuration 030 = Height Of Unit = 2000 BTU/Hr 040 = 4000 BTU/Hr 060 = 6000 BTU/Hr CS030040A-H004 Example Number Translation Classic 30 with Standard Construction 4,000 BTU/Hr 115 V 1Ph 50-60Hz Includes a 400 Watt Heater Option Option Codes H _ = Heater. Requires an additional 3 digits to refer to heater rating. ex: H004=400W A = 115Volt/1Ph/50-60 Hz B = 230Volt/1Ph/50-60Hz B5 = 220Volt/1Ph/50Hz B6 = 230V/1Ph/60Hz Z = 48v DC Dantherm Pinnacle Series Heat Exchangers P=Pinnacle S= Standard Configuration X= Custom Configuration 023 = Height Of Unit = Watts per degree F 015 = Watts per degree F 035 = Watts per degree F 045 = Watts per degree F 055 = Watts per degree F 100 = Watts per degree F PS023011A-T1 Example Number Translation Pinnacle with Standard Construction 35 Watts per degree F 115V 1Ph 50-60Hz Includes a 400 Watt Heater Option Option Codes T= Thermostat GR = Designed for GR testing S = Speed Controller M= Stainless Steel Cover P= Cover Color option A = 115Volt/1Phase/50-60 Hz B = 230Volt/1Phase/50-60Hz Z = 48v DC 4

5 Dantherm CLASSIC 20 Air-Conditioner Model CS ,000 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 2,000 BTU / Hr CS A or B 115V or 230V 1 Ph, Hz Dimensions: 20 H X 10 W X 9 D -H005 Optional: Integrated 500 Watt Heater Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL o F to +113 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection High Quality Powder-coated Cover 5

6 Dantherm CLASSIC 20 Air-Conditioner Dimensional Diagram Mounting Interface 6

7 Dantherm CLASSIC 20 Air-Conditioner Classic Air-flow Diagram Component Locations General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS020020A 2, V 50 / / 25 CS020020B5 1, V / 25 CS020020B6 2, V / 25 Capacity ratings shown above are based on 95 o F (35 o C) return air temperature to cabinet in 95 o F (35 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. 7

8 Dantherm CLASSIC 20 Air-Conditioner ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds 8

9 Dantherm CLASSIC 20 Air-Conditioner Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. Performance Curves 9

10 Dantherm CLASSIC 30 Air-Conditioners Model CS ,000 BTU / Hr. and Model CS ,500 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 4,000 BTU / Hr CS A or B 115V or 230V 1 Ph, Hz Dimensions: 30 H X 19 W X 9 D 7,500 BTU / Hr CS A or B 115V or 230V 1 Ph, Hz Dimensions: 30 H X 19 W X 11 D -H004 Optional: Integrated 400 Watt Heater -H008 Optional: Integrated 800 Watt Heater -H012 Optional: Integrated 1200 Watt Heater 10

11 Dantherm CLASSIC 30 Air-Conditioners Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection Options for GR-487-CORE modifications High Quality Powder-coated Cover Classic Air-flow Diagram Inside View 11

12 Dantherm CLASSIC 30 Air-Conditioner General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS030040A 4,000 1, V 50 / / 45 CS030040B 4,000 1, V 50 / / 45 CS030075A 7,500 2, V 50 / / 48 CS030075B 7,500 2, V 50 / / 48 Capacity ratings shown above are based on 95 o F (35 o C) return air temperature to cabinet in 95 o F (35 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) 12

13 Dantherm CLASSIC 30 Air-Conditioner ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. 13

14 Dantherm CLASSIC 30 Air-Conditioner Dimensional Diagram Mounting Interface 4,000 BTU CLASSIC 30 Air-Conditioner **Mounting pattern for GR version only, call or to request the standard version. 14

15 Dantherm CLASSIC 30 Air-Conditioner Dimensional Diagram Mounting Interface 7,500 BTU CLASSIC 30 Air-Conditioner 15

16 Dantherm CLASSIC 30 Air-Conditioner Performance Curves 4,000 BTU CLASSIC 30 Air-Conditioner 7, 500 BTU CLASSIC 30 Air- Conditioner 16

17 Dantherm CLASSIC 47 Air-Conditioner Model CS047100B 10,000 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 10,000 BTU / Hr CS047100B 230V 1 Ph, Hz Dimensions: 47 H X 19 W X 12 D -H008, H012, H015, H030 Optional: Integrated 800W, 1200W, or 1500W Heater Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection Options for GR-487-CORE modifications High Quality Powder-coated Cover 17

18 Dantherm CLASSIC 47 Air-Conditioner CLASSIC Air-Flow Diagram Dimensional Diagram Mounting Interface 10,000 BTU CLASSIC 47 Air-Conditioner 18

19 Dantherm CLASSIC 47 Air-Conditioner General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS047100B 10,000 3, V / 70 CS047100B 9,000 2, V / 70 Capacity ratings shown above are based on 95 o F (35 o C) return air temperature to cabinet in 95 o F (35 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) 19

20 Dantherm CLASSIC 47 Air-Conditioner ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. 20

21 Dantherm CLASSIC 47 Air-Conditioner Performance Curves 21

22 Dantherm CLASSIC 50 Air-Conditioner Model CS050125B 12,500 BTU / Hr. and Model CS050130B 13,000 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 12,500 BTU / Hr CS050125B 230V 1 Ph, Hz Dimensions: 50 H X 19 W X 15 D -H015 or -H030 Optional: 1500W or 3000W Heater 13,000 BTU / Hr CS050130B 230V 1 Ph, Hz Dimensions: 50 H X 19 W X 13 D -H015 or -H030 Optional: 1500W or 3000W Heater 22

23 Dantherm CLASSIC 50 Air-Conditioner Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection Options for GR-487-CORE modifications High Quality Powder-coated Cover CLASSIC Air-Flow Diagram 23

24 Dantherm CLASSIC 50 Air-Conditioner General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS050125B 12,500 3, V 50 / *15 / / 70 CS050130B 13,000 3, V 50 / *15 / / 70 Capacity ratings shown above are based on 131 o F (55 o C) return air temperature to cabinet in 131 o F (55 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. * NOTE: Breaker / Fuse requirement with no heater and 1500W heater: 15 amp. Breaker / Fuse requirement with 3000W heater: 20 amp. ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) 24

25 Dantherm CLASSIC 50 Air-Conditioner ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. 25

26 Dantherm CLASSIC 50 Air-Conditioner Dimensional Diagram Mounting Interface 12,500 BTU CLASSIC 50 Air-Conditioner 13,000 BTU CLASSIC 50 Air-Conditioner 26

27 Dantherm CLASSIC 50 Air-Conditioner Performance Curves 13,000 BTU CLASSIC 50 Air-Conditioner 27

28 Dantherm CLASSIC 53 Air-Conditioner Model CS053190B 19,000 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number Product Description 19,000 BTU / Hr CS053190B 230V 1 Ph, 60 Hz Dimensions: 53 H X 23 W X 16.5 D -H W Heater Standard Features: Advanced Printed Circuit Control Board Built-in Lead Lag Controller Integral Return Air Thermostat Integrated Self Test Switch Infrared Diagnostic Connection Port Hot Spot Sensor Input Failure Alarm Output Variable Heating and Cooling Settings Condenser Fan on/off Controlled Coated Condenser Coil UL \ cul Recognized Outdoor Rated to UL o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Short Cycle Protection Options for GR-487-CORE modifications High Quality Powder-coated Cover 28

29 Dantherm CLASSIC 53 Air-Conditioner CLASSIC Air-Flow Diagram Dimensional Diagram Mounting Interface 29

30 Dantherm CLASSIC 53 Air-Conditioner Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS053190B 19,000 5, V 60 1 TBC /113 Capacity ratings shown above are based on 131 o F (55 o C) return air temperature to cabinet in 131 o F (55 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. ACG2 Controller LED Trip Indicator Microprocessor Infra-Red LED Alarm Contacts Self-Test Button Cooling Dial Settings from 68 F (20 C) to 104 F (40 C) Heating Dial Settings from 41 F (5 C) to 59 F (15 C) 30

31 Dantherm CLASSIC 53 Air-Conditioner ACG2 Self-Test Button Function A self-test button is provided on the control board of each Classic panel-mount air-conditioner. Simply pressing and holding this button for 6 seconds will activate the self-test sequence as shown in the chart below. During this test, the installer or technician may observe the air-conditioner for the expected function and duration, indicating that all are operating properly. On completion of the self-test, the air-conditioner automatically returns to normal running condition. The control board is also outfitted with an Infrared LED diagnostic port. Optional software and an infrared / RS232 Interface cable are available from Dantherm, enabling the unit to be connected to a portable laptop computer. In this manner, comprehensive and detailed real-time operational data may be observed, diagnostics run, and data imported onto the laptop. Call for more details. Sequence Description Evaporator Fan Heater Compressor Condenser Fan Duration 1 Internal Fan only ON OFF OFF OFF 30 Seconds 2 Heater ON ON OFF OFF 35 Seconds 3 Internal Fan only ON OFF OFF OFF 20 Seconds 4 Compressor & Condenser fan ON OFF ON ON 75 Seconds 5 Internal Fan only ON OFF OFF OFF 30 Seconds Alarm Capabilities All Dantherm Classic units have built-in alarm capabilities programmed into the control board. Failure Modes The following conditions will activate the failure alarm output on terminals 7 and 8: Loss of supply voltage Low Pressure (< 10 psi for 300 seconds) High Pressure (> 400 / 500 psi) Low or no current to compressor (less than 1 amp) High Return Air Temperature (18 o F / 10 o C higher than cooling set point) Low Return Air Temperature (9 o F / 5 o C lower than heater set point) Alarm Connections The alarm cable consists of four wires: Black wire: connected to terminal 7 on the control board Red wire: connected to terminal 8 on the control board White wire: not used Green wire: not used Alarm Description Only the red and black wires are used and are connected to terminals 7 and 8 of the control board. Terminals 7 and 8 operate as a normally closed contactor and open upon failure. During normal operation, a relay is energized, providing continuity between terminals 7 and 8. When a failure is detected, the relay is deenergized such that there is no continuity between terminals 7 and 8. A low voltage signal (up to 50V DC and 0.1 amps) may be connected to the contactors for external alarm capabilities. 31

32 Dantherm CLASSIC 53 Air-Conditioner Performance Curves 19,000 BTU CLASSIC 53 Air-Conditioner Capacity Curve 19K - November 30, Load Btu/hr ºC Ambient 45ºC Ambient 55ºC Ambient Internal Temperature (Return) ºC 32

33 Dantherm CLASSIC Top-Mount Air-Conditioner Model CS ,500 BTU / Hr. Model CS ,500 BTU / Hr. DANTHERM S CLASSIC Line of Air-conditioners is specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Dantherm Part Number CS A or B CS A or B Product Description 3,500 BTU / Hr 115V or 230V 1 Ph, Hz Dimensions: 12-1/4 H X 17-1/4 W X 22 D 5,500 BTU / Hr 115V or 230V 1 Ph, Hz Dimensions: 16-1/4 H X 17-1/4 W X 22 D -H004 or -H008 Optional: Integrated 400W or 800W Heater 33

34 Dantherm CLASSIC Top-Mount Air-Conditioner General Performance Data Dantherm Model BTU/Hr Watts Removal Voltage Hz Ph Full Load Amps Breaker / Fuse Size Approx Wt. lbs. / Kg. CS012035A 3, V 50 / / 58 CS012035B 3, V 50 / / 58 CS016055A 5, V 50 / / 65 CS016055B 5, V 50 / / 65 Capacity ratings shown above are based on 95 o F (35 o C) return air temperature to cabinet in 95 o F (35 o C) ambient conditions at nominal voltage and unimpeded resistance to air flow. Standard Features Closed Loop Cooling Rated for Outdoor Use to UL o F to +131 o F Operating Range High Pressure Switch Low Pressure Switch (inc. bypass timer) Low Ambient Operation Condensation Removal System Short Cycle Protection High Performance Fans UL \ cul Recognized High Quality Powder-coated Cover Product Diagram Component Locations 34

35 Dantherm CLASSIC Top-Mount Air-Conditioner Dimensional Diagram Mounting Interface Classic Top-Mount Air-flow Diagram Introducing. 35

36 Hazardous Duty Cooling At Its Best Completely New Design for explosive environments Cooling unit specifically designed for Class 1, Division 1 hazardous locations All electrical components / connections located on internal loop Operational capacity of 10,000 BTU / hr Available in 480-Volt and 230-Volt 1 Phase High and low pressure switches w/ Lock-out Relay Compressor overload protection w/ Lock-out Relay No electronic controls. simple on / off control Operational temperature up to 131 o F Efficient Rotary Compressor Low ambient control Ambient air filter Alarm output 36

37 Pinnacle Series Air-to-Air Heat Exchangers * Efficient COOLING for indoor & outdoor electronics cabinets & enclosures * DANTHERM S PINNACLE Heat Exchangers are specifically designed for the removal of heat from cabinets containing temperature-sensitive electrical, electronic, or telecommunications equipment. Closed-loop cooling maintains a clean, sealed internal environment to insure optimum performance and maximum life of the enclosed electronics, while protecting against the intrusion of airborne contaminants and humidity. Quality Efficiency Durability Versatility Simplicity Available in 48V DC and 115V and 230V AC Voltages. Closed-loop cooling removes heat and protects electronics from humidity & contaminants. Options for GR-487-CORE compliance for corrosion resistance and wind-driven rain. Compact design allows for wide variety of mounting configurations and applications. Units mount quickly and easily to outside of cabinet or enclosure. Longest standard warrantee in the industry at 18 months. UL Recognized or Listed to UL 484 for outdoor use. Optional temperature control and alarm strategies. Units are manufactured here in the United States. Efficient coated aluminum heat-transfer core. Low maintenance; CFC and refrigerant free. 37

38 Pinnacle Series Air-to-Air Heat Exchangers Every Pinnacle Series Heat Exchanger incorporates an efficient and durable epoxy-coated aluminum heat-transfer core manufactured on state-of-the-art equipment exclusive to Dantherm. General Performance Data Model Number Voltage Performance in Watts / o F Performance in Watts / o C Dimensions Full Load Amps. Breaker / Fuse Weight (lbs.) PS023011A 115V AC "H x 12"W x 5"D PS023011B 230V AC "H x 12"W x 5"D PS023011Z 48V DC "H x 12"W x 5"D PS035015A 115V AC "H x 18"W x 3.6"D PS035015B 230V AC "H x 18"W x 3.6"D PS035015Z 48V DC "H x 18"W x 3.6"D PS035035A 115V AC "H x 18"W x 6.8"D PS035035B 230V AC "H x 18"W x 6.8"D PS035035Z 48V DC "H x 18"W x 6.8"D PS035045A 115V AC "H x 18"W x 6.8"D PS035045B 230V AC "H x 18"W x 6.8"D PS035045Z 48V DC "H x 18"W x 6.8"D PS035055A 115V AC "H x 18"W x 8.8"D PS035055B 230V AC "H x 18"W x 8.8"D PS035055Z 48V DC "H x 18"W x 8.8"D PS060100B 230V AC "H x 24W" x 14"D

39 Pinnacle Series Air-to-Air Heat Exchangers Dimensional Diagrams Mounting Interfaces Pinnacle PS Models Pinnacle Series Air-to-Air Heat Exchangers 39

40 Pinnacle Series Air-to-Air Heat Exchangers Dimensional Diagrams Mounting Interfaces Pinnacle PS0350XX Models Pinnacle PS060100B Model 40

41 Pinnacle Series Air-to-Air Heat Exchangers Dimensional Diagrams Mounting Interfaces Pinnacle PS Models 41

42 Pinnacle Series Air-to-Air Heat Exchangers Heat Exchanger Performance Curves Total Heat Dissipation (Watts) Temperature Delta in 0 F PS PS PS PS PS PS

43 Dantherm Custom Products Air-Conditioners & Heat Exchangers Ask about Dantherm Global Design Capabilities 43

44 Introducing. Dantherm New Technologies & Innovations Plastic Foil Heat Exchanger Solutions Improved fuel cell technologies Pressurized ventilation systems Others in development 44

45 Global Expertise, Resources, and Capabilities. Local Commitment to Quality Products and Exceptional Customer Service. Focus. Trust. Initiative. 45

46 For Personal Assistance or Ordering: The information contained in this document is subject to change without notification. For personal assistance in product sizing, pricing, or model selection, call, fax, or your questions, specifications, or requirements to: Dantherm Contact Responsibility Title Direct Phone Address Rick Gromlovits Commercial Sales Manager Electronics Cooling (704) Rick Schmidt Technical Engineering Manager (864) Lourdes Sisk Customer Service & Marketing Customer Service (864) & Marketing Manager Dantherm Air Handling, Inc Orchard Park Blvd. Spartanburg, SC Phone: (864) Fax: (864)

Panel Mounted Air Conditioners by Dantherm, Inc.

Panel Mounted Air Conditioners by Dantherm, Inc. Panel Mounted Air Conditioners by Dantherm, Inc. CS020020A/B with USACG-6 Control PRODUCT INFORMATION MANUAL AC-2 CS020020 USACG-6 Manual Rev H Page 1 of 17 Dantherm, Inc. 110 Corporate Drive, Suite K

More information

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT? Data Bulletin April 2001 Raleigh, NC, USA Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW Variable frequency drives are available from manufacturers as enclosed engineered

More information

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09 0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

IV. Rear Mount System

IV. Rear Mount System Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading

More information

NSN 4120-01-21 4-3692

NSN 4120-01-21 4-3692 *TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

*.ppt 11/2/2009 12:48 PM 1

*.ppt 11/2/2009 12:48 PM 1 Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Engineering Specifications

Engineering Specifications Engineering Specifications NORDIC W-85-H-B-*S-PD Water to Water Heat Pump Single-Stage R134a Nominal 7.5 Ton With Double Wall Condenser for Domestic Hot Water Production Maritime Geothermal Ltd. P.O. Box

More information

Specification Requirements DBL 700MX and 1000MX Series UPS

Specification Requirements DBL 700MX and 1000MX Series UPS Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

MP-4000 Alarm List (Software version 2.4.3 or later)

MP-4000 Alarm List (Software version 2.4.3 or later) Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU GENERAL PURPOSE (ORDINARY) LOCATION Custom Controls provides the petro-chemical and offshore industries with HVAC equipment of the highest quality and reliability on the market at an economical price.

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY About HDT Nordic HDT Global, in business for over 75 years, acquired Nordic Air in 2010. Nordic was founded

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6 TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL

More information

T-Series Air Conditioner T62 Model

T-Series Air Conditioner T62 Model INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

WALL MOUNTED SPLIT TYPE AIR CONDITIONER WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Commercial Refrigeration Temperature and Defrost Controls

Commercial Refrigeration Temperature and Defrost Controls Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys

More information

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost

More information

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167 PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Model #: SMART2200CRMXL

Model #: SMART2200CRMXL Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for

More information

catalog Single Package Vertical Air Conditioners and Heat Pumps

catalog Single Package Vertical Air Conditioners and Heat Pumps catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................

More information

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Self-Retracts 30 ft. Charge Cable Length Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Safe, Convenient & Clean EV Charging The EVoReel cable management solutions

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 T-SERIES Air Conditioners T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 88043249 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with

More information

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor Executive Summary Choosing the right air conditioners for enclosures can have a tremendous

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion Rectifiers Microprocessor controlled rectifier technology Fully adjustable float, boost and equalizing charge modes with V/I characteristic Advanced technology for phase control Verylowvoltage ripple and

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity NetXtend Flex Series Integrated Outdoor Enclosure Solution Outside Plant for Business-Critical Continuity Features & Benefits Full flexibility and scalability one enclosure for various telecommunication

More information

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output. Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration

More information

Air Conditioning Sign-Off Sheet

Air Conditioning Sign-Off Sheet Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate

More information

Single Zone LCD Thermostat Operating Instructions

Single Zone LCD Thermostat Operating Instructions Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip

More information

VLT Series 300 Watt True Sine Wave Inverter

VLT Series 300 Watt True Sine Wave Inverter VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 36 16-90 Corso Lino Zanussi, 30 031117 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434

More information

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Air Conditioner Water Heater - A Product of HotSpot Energy LLC Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Air conditioning, electrical testing

Air conditioning, electrical testing just a test. Air conditioning, electrical testing 01-253 Wire and component test using VAG1598 A test box Special tools and equipment VAG 1598 A test box and VAG 1598/11 adapter cable and VAG 1598/12 VAG1526

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner

More information

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Electronic, Digital and Mechanical Vibration Switches

Electronic, Digital and Mechanical Vibration Switches PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information