TECHNICAL GUIDE LISTED

Size: px
Start display at page:

Download "TECHNICAL GUIDE LISTED"

Transcription

1 T I I I T G TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER AC012M102 THRU AC030M1021 (1 THRU 2.5 NOMINAL TONS, 1 PH) AC036X102 THRU 60 (3 THRU 5 NOMINAL TONS, 1 PH) AC036X10(3,4) THRU 60 (3 THRU 5 NOMINAL TONS, 3 PH) This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO U R A C T MA N U F R E C E UN I R T I C ER T A R I A RY F F I E D E Q U I C A T T S A Certification applies only when the complete system is listed with ARI. AC012M1021 THRU 030 AC036X1021 THRU 060 AC036X10(31,41) THRU 060 LISTED Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at for the most up-to-date technical information. Additional rating information can be found at T R P ON O T M E N S A R I AI E CT N D A R R - C I D AS ONDI ON S 2 O I C 1 0 OM P NI N G OF L Y N I W IT H DESCRIPTION Rev. E (0405) The 10 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom-matched with one of UPG s complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal applications to provide a complete system. Electric Heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces and air handlers. WARRANTY 5-year limited parts warranty. 5-year limited compressor warranty. FEATURES QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins. COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted desert sand finish insure less fading when exposed to sunlight. LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls and the molex plug in the control box connecting the condenser fan, make for easy servicing of the unit. SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. U.L. AND C.U.L. LISTED - Approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

2 Physical and Electrical Data - 1 Phase MODEL 012M M M M X X X X1022 Unit Supply Voltage 208/ Normal Voltage Range 187 to 252 Minimum Circuit Ampacity Max. Overcurrent Device Amps Compressor Type Rotary Recip Recip Recip Recip Recip Recip Scroll B Rated Load Compressor Amps Locked Rotor Crankcase Heater No No No No No No No No Fan Motor Amps Rated Load Fan Diameter Inches 17-1/2 17-1/2 17-1/2 17-1/ Fan Motor Rated HP 1/12 1/12 1/8 1/8 1/4 1/4 1/4 1/4 Nominal RPM 1,100 1,100 1,075 1,075 1,100 1, Nominal CFM 1,600 1,550 1,750 1,750 2,750 2,750 3,250 3,300 Face Area Sq. Ft Coil Rows Deep Fin / Inches Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 5/8 5/8 5/8 3/4 3/4 3/4 7/8 7/8 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz Operating Weight Lbs Physical and Electrical Data - 3 Phase MODEL AC036X1031 AC048X1031 AC060X1031 AC036X1041 AC048X1041 AC060X1041 Unit Supply Voltage 208 / Normal Voltage Range Minimum Circuit Ampacity Max. Overcurrent Device Amps Compressor Type 3 Recip Recip Scroll B Recip Recip Scroll B Compressor Amps Rated Load Locked Rotor Crankcase Heater No No No No No No Fan Motor Amps Rated Load Fan Diameter Inches Rated HP 1/4 1/4 1/4 1/4 1/5 1/4 Fan Motor Nominal RPM 1, , Nominal CFM 2,750 3,250 3,450 2,750 3,250 3,450 Face Area Sq. Ft Coil Rows Deep Fin / Inch Liquid Line OD 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line OD 3/4 7/8 7/8 3/4 7/8 7/8 Unit Charge (Lbs. - Oz.) Charge Per Foot, Oz Operating Weight Lbs Rated in accordance with ARI Standard 110, utilization range A. 2. Dual element fuses or HACR circuit breaker. 3. All scrolls listed with a superscript B are Bristol scrolls. All scrolls listed with a superscript C are Copeland scrolls. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. 2 Unitary Products Group

3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 PHASE ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS Outdoor Unit 012M M M M X X X X1022 Unit Orifice (s) Factory R-22 Charge, lbs-oz Indoor Coil Coil Orifice 2 System Orifice - Additional Charge, Oz G2FD024(S,H)14/ G2FD030(S,H) G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) G2FD048(S,H)21/ G1HA024H G1HA036H G1HA036H G1HA048H G1HA060H G1FA/G1UA024S14/ G1FA/G1UA030S G1FA/G1UA036S G1FA/G1UA03617/ G1FA/G1UA048S G1FA/G1UA048S G1FA/G1UA060S G1NA024S17G G1NA030S17H G1NA030S17K G1NA030S21B G1NA030S21M G1NA036S17J G1NA036S21C G1NA048S21D G1NA048S24P G1NA060S24T G1NF024SOF G1NF036SOF G1NF048SOF G1NF060SOF F2RP/F2FP F2RP/F2FP F2RP/F2FP F2RC/F2FC F2RP/F2FP F2RP/F2FP F2FP048N F2FP060N FOOTNOTES: 1. These orifices are packed in the customer packet of each outdoor unit. 2. These orifices are factory mounted in the flow control device of each indoor coil. 3. Systems matched with furnaces or air handlers not equipped with blower-off delays, may require blower Time Delay Kit #6918A5011. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table. 3. Add charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaportor + adder for line set. 5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size. Unitary Products Group 3

4 Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 PHASE ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS Outdoor Unit AC036X AC048X AC060X Unit Orifice (s) Factory R-22 Charge, lbs-oz Indoor Coil Coil Orifice 2 System Orifice = Additional Charge, Oz G1NA036S17J G1NA036S21C G1NA048S21D G1NA048S24P G1NA060S24T G1FA/G1UA036S17/ G1FA/G1UA048S G1FA/G1UA060S21/ G2FD036(S,H) G2FD036(S,H) G2FD042(S,H)21 78 G2FD048(S,H)21/ G2FD060(S,H) G1NF036SOF G1NF048SOF G1NF060SOF FOOTNOTES: 1. These orifices are packed in the customer packet of each outdoor unit. 2. These orifices are factory mounted in the flow control device of each indoor coil. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor and for 15 feet of interconnecting line tubing. 2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaportor + adder for line set. 5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size. 4 Unitary Products Group

5 COOLING CAPACITY - With Air Handler Coils AIR HANDLER UNIT MODEL MODEL ELECTRIC 2 HEAT KW COIL 1 MODEL COOLING NET MBH SEER TOTAL SENS. W/O TXV 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters. 3. TXV = Use 1TV700 Series Kit. 4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same. 5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard. - = Not applicable. W RATED CFM SEER + TXV 3 EER 1 PH 10 SEER AC WITH N1AH / G2FD AC012M1021 N1AHB G2FD024(S,H) AC018M1021 N1AHB G2FD024(S,H) AC024M1021 N1AHB G2FD024(S,H) AC030M1021 N1AHB ,15,18 17 G2FD030(S,H) AC036X1021 N1AHB ,15,18 17 G2FD036(S,H) AC042X1021 N1AHC ,15,18 21 G2FD042(S,H) AC048X1021 N1AHC ,15,18 21 G2FD048(S,H) AC060X1022 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H) PH 10 SEER AC WITH N1AH / G2FD AC036X10(31,41) N1AHB ,15 21 G2FD036(S,H) AC036X10(31,41) N1AHB ,15 21 G2FD042(S,H) AC048X10(31,41) N1AHC ,15 21 G2FD048(S,H) AC048X10(31,41) N1AHD ,15,29 24 G2FD048(S,H) AC048X10(31,41) N1AHD ,15,29 24 G2FD048(S,H) AC060X10(31,41) N1AHD ,15,29 24 G2FD060(S,H) PH 10 SEER AC / F2RP / RC / FC 4, 5 AC012M1021 F2RP018 2,5, AC012M1021 M1HC AC018M1021 F2RP/F2FP018 2,5, AC018M1021 F2RP/F2FP024 5,8, AC024M1021 F2RP/F2FP024 5,8, AC024M1021 F2RP/F2FP024 5,8, AC030M1021 F2RP/F2FP030 5,8,10, AC030M1021 F2RP/F2FP036 5,8,10,15, AC036X1021 F2RC/F2FC036 5,8,10, AC036X1021 F2RP/F2FP036 5,8,10,15, AC036X1021 F2RP/F2FP042 5,8,10, AC042X1021 F2FP048 5,8,10,15,20, AC042X1021 F2RP/F2FP042 5,8,10, AC048X1021 F2FP048 5,8,10,15,20, AC048X1021 F2FP060 5,8,10,15,20, AC060X1022 F2FP060 5,8,10,15,20, PH 10 seer AC with F2RP / FP AC036X10(31,41) F2RC/F2FC036 5,8,10, AC048X10(31,41) F2FP048 5,8,10,15,20, AC060X10(31,41) F2FP060 5,8,10,15,20, Rated in accordance with DOE test procedures (Federal Register and ) and ARI Standards 210/240. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. Unitary Products Group 5

6 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils FURNACE** COOLING COIL UNIT MODEL NET MBH W MODEL RATED CFM AC012M1021 AC018M1021 AC024M1021 AC030M1021 AC036X1021 CFM RANGE (MIN.-MAX.) TOTAL SENS. SEER W/O TXV SEER + TXV 1 14,17 G1FA024S14, G1HD G1NA024S17G ,17 G1UA024S14, ,17 G2FD024(S,H)14, ,17 G1FA024S14, G1HA024H G1HD G1NA024S17G ,17 G1UA024S14, ,17 G2FD024(S,H)14, ,17 G1FA024S14, G1FA036S G1HA024H G1HA036H G1HD G1NA030S17H G1NA030S21B ,17 G1UA024S14, G1UA036S ,17 G2FD024(S,H)14, G1FA030S G1FA036S ,21 G1FA036S17, G1HA036H G1HA036H G1HD G1NA030S17K G1NA030S21M G1UA030S G1UA036S ,21 G1UA036S17, G2FD030(S,H) G2FD035(S,H) G1FA036S ,21 G1FA036S17, G1FA048S ,24 G1FA048S G1HA036H G1HA036H G1HA048H G1HD G1HD G1NA036S17J G1NA036S21C G1UA036S ,21 G1UA036S17, G1UA048S ,24 G1UA048S G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) G2FD046(S,H) EER 6 Unitary Products Group

7 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL NET MBH W MODEL RATED CFM AC036X10(31,41) For Notes See Page 5. AC042X1021 AC042X1031,41 AC048X1021 AC048X10(31,41) CFM RANGE (MIN.-MAX.) TOTAL SENS. SEER W/O TXV SEER + TXV 1 17,21 G1FA036S17, ,24 G1FA048S G1NA036S17J G1NA036S21C ,21 G1UA036S17, ,24 G1UA048S G2FD036(S,H) G2FD036(S,H) G1FA048S ,24 G1FA048S ,24 G1FA060S21, G1HA036H G1HA048H G1HD G1NA036S21C G1NA048S21D G1UA048S ,24 G1UA048S ,24 G1UA060S21, G2FD042(S,H) G2FD046(S,H) ,24 G2FD048(S,H)21, G2FD060(S,H) ,24 G1FA048S ,24 G1FA060S21, G1NA036S21C G1NA048S21D ,24 G1UA048S ,24 G1UA060S21, G2FD042(S,H) G2FD046(S,H) ,24 G2FD048(S,H)21, G1FA048S ,24 G1FA048S ,24 G1FA060S21, G1HA048H G1HA060H G1HD G1HD G1NA048S21D G1UA048S ,24 G1UA048S ,24 G1UA060S21, G2FD046(S,H) ,24 G2FD048(S,H)21, G2FD060(S,H) ,24 G1FA048S G1NA048S21D ,24 G1UA048S ,24 G2FD048(S,H)21, EER Unitary Products Group 7

8 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued) FURNACE** COOLING COIL UNIT MODEL NET MBH W MODEL RATED CFM AC060X1022 AC060X10(31,41) CFM RANGE (MIN.-MAX.) TOTAL 21,24 G1FA060S21, G1HA060H G1HD G1NA048S21D G1NA060S24T ,24 G1UA060S21, G2FD060(S,H) G2FD061H ,24 G1FA060S21, G1NA060S24T ,24 G1UA060S21, G2FD060(S,H) TXV = Use 1TV700 Series Kit. * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. COOLING PERFORMANCE MODEL AC012M1021 AC018M1021 AC024M1021 AC030M1021 AC036X1021 AC036X10(31,41) SENS. SEER W/O TXV SEER + TXV 1 SUCT. AIR TEMP ON CONDENSER SUCT. AIR TEMP ON CONDENSER COMPR. 75ºF 95ºF 115ºF MODEL COMPR. 75ºF 95ºF 115ºF TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW AC042X AC048X AC048X10(31,41) AC060X AC060X10(31,41) NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat. 2. Performance based on 15 superheat and 15 sub-cooling at condensing unit. a. Increase capacity 1% for each 2 increase in sub-cooling. b. Decrease capacity 1% for each 2 decrease in sub-cooling. 3. Sub-cooling in excess of 20 may result in excessively high condensing temperature with air on condenser above 115 F. Maximum recommended condensing temperature is 140 F. EER 8 Unitary Products Group

9 A A B C B C 1. Including Fan guard. ACCESSORIES* Refer to Price Manual for specific model numbers. Hard Start Kit - Provides increased starting torque for areas with low voltage. Compressor Blanket - Designed to further reduce the normal compressor operating sound. Refer to price pages for specific match-ups. Off Cycle Timer Delay - Provides a 5-minute off cycle to prevent rapid recycling of the compressor. Room Thermostats - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation. 1 Heat Stage only, manual, mechanical thermostat. Add subbase for 1H/1C. 1H/1C, manual change-over electronic non-programmable thermostat. 1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat. 1H/1C, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the price book or consult factory. SOUND POWER RATINGS* DIMENSIONS - 1 Phase Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A 1 B C Liquid Vapor /4 21-3/ /4 21-3/ /4 21-3/ /4 21-3/ /8 3/4 2 3/4 7/8 UNIT MODEL (dba) *Rated in accordance with ARI Standards. 1. Including Fan guard. 2. Reducer fitting required for 5/8 line set. DIMENSIONS - 3 Phase Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A 1 B C Liquid Vapor /8 3/ /8 7/ /8 7/8 Unitary Products Group 9

10 TYPICAL INSTALLATION - AC012M1021 THRU 030 AND AC036X1021 THRU CLEARANCE AROUND PERIMETER 1 TO 2.5 TON, 10 SEER ( M SERIES ONLY) 60 OVERHEAD CLEARANCE MINIMUM 18 SERVICE ACCESS CLEARANCE ON ONE SIDE WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10 CLEARANCE COIL AREA 3 TO 5 TONS, 10 SEER TO INDOOR COIL NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL TYPICAL FIELD WIRING - 1 PHASE APPLICATION ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/ VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) POWER WIRING CONTROL WIRING FACTORY WIRING * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. FURNACE OR AIR HANDLER TERMINAL BLOCK C Y R G W GND. LUG CONTACTOR TERMINALS COIL Y R G W * CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. ROOM THERMOSTAT USE COPPER CONDUCTORS ONLY. TYPICAL FIELD WIRING - 3 PHASE APPLICATION ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/ VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) POWER WIRING CONTROL WIRING FACTORY WIRING FURNACE OR AIR HANDLER TERMINAL BLOCK GND. LUG CONTACTOR TERMINALS COIL * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. C Y R G W * Y R G W CONDENSING UNIT ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. 10 Unitary Products Group

11 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC012M1021 G1NA024S17G ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB0806 G2FD024(S,H) F2RP M1HC G1FA024S14, G1HD G1UA024S14, G2FD024(S,H)14, Unitary Products Group 11

12 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC018M1021 G1NA024S17G ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB0806 G2FD024(S,H) F2RP/F2FP F2RP/F2FP G1FA024S14, G1HD G1NA024S17G G1UA024S14, G2FD024(S,H)14, Unitary Products Group

13 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC024M1021 G1NA030S17H ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB0806 G2FD024(S,H) F2RP/F2FP F2RP/F2FP G1FA024S14, G1FA036S G1HD G1NA030S17H G1NA030S21B G1UA024S14, G1UA036S G2FD024(S,H)14, Unitary Products Group 13

14 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC030M1021 G1NA030S17K ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHB1206 G2FD030(S,H) F2RP/F2FP F2RP/F2FP G1FA030S G1FA036S G1FA036S17, G1HD G1NA030S21M G1UA030S G1UA036S G1UA036S17, G2FD030(S,H) G2FD035(S,H) Unitary Products Group

15 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC036X1021, AC036X10(31,41) G1FA036S17,21 ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. 1 Phase 3 Phase Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1AHB1206 G2FD036(S,H) N1AHB1246 G2FD036(S,H) N1AHB1206 G2FD046(S,H) N1AHB1246 G2FD046(S,H) F2RC/F2FC F2RC/F2FC F2RP/F2FP G1FA048S F2RP/F2FP G1NA036S17J G1FA036S G1NA036S21C G1FA048S G1UA036S17, G1FA048S G1UA048S G1HD G2FD036(S,H) G2FD046(S,H) G2FD036(S,H) G1HD G1NA036S17J G1NA036S21C G1UA036S G1UA036S17, G1UA048S G1UA048S G2FD035(S,H) G2FD036(S,H) G2FD036(S,H) G2FD042(S,H) Unitary Products Group 15

16 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC042X1021, AC042X10(31,41) G1FA048S21 ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. 1 Phase 3 Phase Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1AHC1606 G2FD042(S,H) N1AHC1646 G2FD042(S,H) N1AHC1606 G2FD048(S,H) N1AHC1646 G2FD048(S,H) F2RP/F2FP F2RP/F2FP F2FP F2FP G1FA048S G1FA060S21, G1FA060S21, G1NA036S21C G1HD G1NA048S21D G1NA036S21C G1UA048S G1NA048S21D G1UA060S21, G1UA048S G2FD042(S,H) G1UA048S G2FD046(S,H) G1UA060S21, G2FD048(S,H)21, G2FD042(S,H) G2FD046(S,H) G2FD048(S,H)21, G2FD060(S,H) Unitary Products Group

17 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC048X1021, AC048X10(31,41) G1FA048S21 ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. 1 Phase 3 Phase Air Handler Coil T.C. S.C. KW Air Handler Coil T.C. S.C. KW N1AHC1606 G2FD048(S,H) N1AHC1646 G2FD048(S,H) N1AHD2006 G2FD060(S,H) N1AHD2046 G2FD048(S,H) F2FP N1AHD2046 G2FD060(S,H) F2FP F2FP G1FA048S G1FA048S G1FA060S21, G1NA048S21D G1UA048S G1UA048S G1HD G2FD048(S,H)21, G1HD Unitary Products Group 17

18 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC060X1022 G1FA060S21,24 ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHD2006 G2FD060(S,H) F2FP G1HD G1NA048S21D G1NA060S24T G1UA060S21, G2FD060(S,H) G2FD061H Unitary Products Group

19 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. INDOOR COIL MODEL NO. CONDENSER ENTERING AIR TEMPERATURE AC060X10(31,41) G2FD060(S,H)24A ID CFM ID DB ( F) ID WB ( F) T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W T.C S.C K.W Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature. Air Handler Coil T.C. S.C. KW N1AHD2046 G2FD060(S,H) F2FP G1FA060S21, G1NA060S24T G1UA060S21, Unitary Products Group 19

20 MATCHING INDOOR COMPONENTS ADD-ON COILS - FOR FURNACE APPLICATIONS G1UA 1/2 CASED UPFLOW G1HD HORIZONTAL DUCT G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW G2FD* MULTI-POSITION (UPFLOW, HORIZONTAL AND DOWNFLOW) * Available with factory installed horizontal drain pan. AIR HANDLERS - FOR NON-FURNACE APPLICATIONS N-AH OR N-VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW) G+FD COIL F+RC / F+FC OR F+RC / F+FP FAN COIL UNITS (UPFLOW, HORIZONTAL) Subject to change without notice. Printed in U.S.A Rev. E (0405) Copyright by York International Corp All rights reserved. Supersedes: Rev. D (0604) Unitary 5005 Norman Product York OK Group Drive 73069

SPLIT-SYSTEM CONDENSING UNITS. 10.00 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

SPLIT-SYSTEM CONDENSING UNITS. 10.00 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES 550.46 -TG1Y (196) SPLIT-SYSTEM CONDENSING S 0 SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION The HRA Series condensing unit is the outdoor part of a versatile system of air conditioning. It

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

Product Data. Split System Cooling 22-1904-1F-EN. March 2015

Product Data. Split System Cooling 22-1904-1F-EN. March 2015 Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data Three Phase 4TTA3 2½ 5 Tons PUB. NO. 22-1791-12 Features and Benefits All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant

More information

Split System Cooling Product & Performance Data

Split System Cooling Product & Performance Data Split System Cooling Product & Performance Data XR 13 4TTR3018-060 1½ 5 Tons PUB. NO. 22-1790-02-2607 (EN) Features and Benefits Climatuff compressor Efficiency up to 14.00 SEER All aluminum Spine Fin

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XR 13 4TWR3018-060 1½ 5 Tons PUB. NO. 22-1795-12 Features and Benefits Climatuff compressor All aluminum Spine Fin coil Quick-Sess cabinet, service access and refrigerant

More information

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Three Phase 4TWA3030A3000C 4TWA3030A4000C 4TWA3036A3000C 4TWA3036A4000C 4TWA3042B3000A 2½ 5 Tons 4TWA3042B4000A 4TWA3048A3000C 4TWA3048A4000C 4TWA3060B3000A 4TWA3060B4000A

More information

Local Dealer: www.cebrands.com

Local Dealer: www.cebrands.com Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication

More information

GCS16 GCS20 WARNING CAUTION

GCS16 GCS20 WARNING CAUTION Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

catalog Single Package Vertical Air Conditioners and Heat Pumps

catalog Single Package Vertical Air Conditioners and Heat Pumps catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060 4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

GCS16-024-030-036-048-060

GCS16-024-030-036-048-060 Packaged Unit & Gas Heat 2-5 Ton Capacity 50,000-120,000 Btuh Input Heating Capacity GCS16-024-030-036-048-060 FEATURES Designed for outdoor rooftop or ground level installations Down-flow or horizontal

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION OUTDOOR SPLIT-SYSTEM AIR CONDITIONER MODELS: 10, 12, 13 AND 14 SEER 1 PHASE - 1.5 TO 5 TONS TABLE OF CONTENTS GENERAL INFORMATION.................... 2 INSPECTION..............................

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils Heating&Air Conditioning RHF High Efficiency Remote Heat Pumps and Matching Blower Coils Amana RHF heat pumps and matching blower coils offer economy, superior heating and cooling comfort, plus installation

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost

More information

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as: CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

AIR-COOLED CONDENSERS Technical Guide

AIR-COOLED CONDENSERS Technical Guide BN-ACCTB0306 March, 2006 AIR-COOLED CONDENSERS Technical Guide Monarch and Ambassador Series TABLE OF CONTENTS Overview... 2, 3 Features & Options... 3, 4 Three Solutions...5 Nomenclature...6 Condenser

More information

Greensource iseries HY Model Unitary Air Handler/Fan Coil

Greensource iseries HY Model Unitary Air Handler/Fan Coil Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL Performancet Series Fan Coil Sizes 002 Thru 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The is the premium air handler combining the proven technology of Carrier fan coils with environmentally

More information

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

Packaged Cooling with Electric Heat Rooftop Units

Packaged Cooling with Electric Heat Rooftop Units Packaged Cooling with Electric Heat Rooftop Units Voyager 12½ - 25 Tons - 60 Hz December 2003 RT-PRC002-EN Introduction Voyager TM... a proven performer built to provide ultimate indoor comfort. Voyager

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

CB29M Bulletin #490071 February 1996

CB29M Bulletin #490071 February 1996 ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating

More information

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents. The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

Product Data. FV4B Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

Product Data. FV4B Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL Performancet Series Fan Coil Sizes 002 Thru 006 Product Data PREMIUM ENVIRONMENTALLY SOUND FAN COIL The is the premium air handler combining the proven technology of Carrier fan coils with environmentally

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODEL: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual : 2100-234 E Supersedes: 2100-234

More information

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

Packaged Gas/Electric Rooftop Units

Packaged Gas/Electric Rooftop Units Packaged Gas/Electric Rooftop Units Voyager 12½ 25 Tons 60 Hz December 2003 Introduction Voyager TM... a proven performer built to provide ultimate indoor comfort. Voyager continues to provide the highest

More information

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into

More information

TECHNICAL MANUAL GDS8 & GHS8

TECHNICAL MANUAL GDS8 & GHS8 TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications

More information

Air Conditioners (Outdoor)

Air Conditioners (Outdoor) 14/06/13 A1 Air Conditioners (Outdoor) Outdoor Condenser Units - R-410A Refrigerant Split System Air Conditioners, 208/230 Volt, Single Phase Designed using galvanized steel Composite base pan absorbs

More information

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions. LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Installation Instructions

Installation Instructions 05,06 Single Package, Displacement Ventilation or Single Zone Variable Airflow Rooftop Units Electric Cooling with PURONr (R---410A) Refrigerant and COMFORTLinkt Controls Installation Instructions IMPORTANT:

More information

PACKAGE COOLING, PACKAGE HEAT PUMP & PACKAGE GAS UNITS

PACKAGE COOLING, PACKAGE HEAT PUMP & PACKAGE GAS UNITS PACKAGE COOLING, PACKAGE HEAT PUMP & PACKAGE GAS UNITS SERVICE INSTRUCTIONS AMANA REFRIGERATION, INC., AMANA, IOWA 52204 MANUFACTURING NUMBERS COVERED IN THIS MANUAL SEE MODEL AND MANUFACTURING NUMBERS

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Packaged Gas/Electric Rooftop Units

Packaged Gas/Electric Rooftop Units Packaged Gas/Electric Rooftop Units Precedent 3-10 Tons 60 Hz October 2004 Introduction Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete line of Packaged

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 23 62 13 - AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS 1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners & Heat Pumps Unit Application Bebco Model IX-WAC/HP Industrial Grade Air Conditioners & Heat Pumps are designed as a total

More information

F9MXE. Product Specifications

F9MXE. Product Specifications 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

CARRIER REFRIGERATION EQUIPMENT AND PARTS

CARRIER REFRIGERATION EQUIPMENT AND PARTS EVAPORATOR COILS CONDENSING UNITS 1/2 Through 80 HP COMPLETE REFRIGERATION PACKAGES AIR DEFROST ELECTRIC DEFROST HOT GAS DEFROST Ceiling Temp Low Height Unit Coolers SW Series Literature No. C 230.0 January,

More information

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY About HDT Nordic HDT Global, in business for over 75 years, acquired Nordic Air in 2010. Nordic was founded

More information

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU GENERAL PURPOSE (ORDINARY) LOCATION Custom Controls provides the petro-chemical and offshore industries with HVAC equipment of the highest quality and reliability on the market at an economical price.

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

10ACC WARNING WARNING. Service Literature 10ACC SERIES UNITS

10ACC WARNING WARNING. Service Literature 10ACC SERIES UNITS Service Literature ACC SERIES UNITS ACC Corp. 0201 L1 Revised 08 2004 The ACC is a residential split-system condensing unit available in sizes ranging from 1 1/2 to 5 tons. Condensing coil size, circuiting

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

HVAC Basic Science - System Capacity

HVAC Basic Science - System Capacity HVAC Basic Science - System Capacity Btu/hour, btu/h, b/h, btuh. btu?? 1 MBH = 1000 btu/hour 1 KBH = 1000 btu/hour 1 ton of cooling= 12,000 btu/hour 1 watt = 3.414 btu/hour 1 kilowatt = 1000 watts = 3,414

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same

More information

WATER-COOLED VERTICAL PACKAGED AIR CONDITIONERS 5-Ton through 30-Ton Capacity

WATER-COOLED VERTICAL PACKAGED AIR CONDITIONERS 5-Ton through 30-Ton Capacity 9700C VPAC SERIES WATER COOLED WATER-COOLED S 5-Ton through 30-Ton Capacity RSI Company 12911 Taft Avenue, Cleveland, Ohio 44108 PH: 216-451-9300 FAX: 216-451-9376 Web: www.rsicomp.com Email: info@rsicomp.com

More information

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R

More information

123 street Salt Lake City, Utah 84092

123 street Salt Lake City, Utah 84092 Salt Lake City, Utah 84092 Prepared for: Sample AC inspection Prepared by: Page 1 of 8 Table of Contents Definitions 2 General Information 2 Air Conditioning 3 Heating System 6 Summary 8 Page 2 of 8 Definitions

More information

Basic Nameplate Information

Basic Nameplate Information Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information