Guidelines for Fire Safety Plans. Halifax Regional Fire & Emergency Services Fire Prevention and public Education
|
|
- Shanon Hutchinson
- 7 years ago
- Views:
Transcription
1 Guidelines for Fire Safety Plans Halifax Regional Fire & Emergency Services Fire Prevention and public Education
2 Why Plan For Fire Safety Let s Look At The Facts Structure Fires In Office Properties In North America for ,500 fires 5 Civilian Deaths 62 Civilian Injuries $147.1 Million Dollars in Property Damage
3 Industrial and Manufacturing Properties 17,200 Fires 29 Civilian Deaths 609 Civilian Injuries Over 1 Billion Dollars in Property Damage
4 Lets Look at The legislation The Fire Safety Act Province of Nova Scotia Formal Adoption of The National Fire Code of Canada 1995 HRM By-Law F-100 Respecting Fire Prevention Also Formally Adopts the National Fire Code of Canada 1995
5 Responsibilities of the Owner The Fire Safety Act Defines owner as a person controlling land or premises or activity on the land or premises. An occupant may be considered the owner. Duty to take fire safety precautions Section 17 Unless this Act or the regulations otherwise prescribe, every owner of land or premises, or part thereof, shall take every precaution that is reasonable in the circumstances to achieve fire safety and to carry out the provisions of this Act, the regulations and the Fire Code
6 National Fire Code Of Canada Section 2.8 Emergency Planning Application 1) Fire emergency procedures conforming to this Section shall be provided for a) every building containing an assembly or a care or detention occupancy. b) every building required by the National Building Code of Canada 1995 to have a fire alarm system
7 National Fire Code Continued c) demolition and construction sites regulated under section of this Code d) storage areas required to have a fire safety plan in accordance with Articles and , e) areas where flammable liquids or combustible liquids are stored or handled in conformance with Article And, f) areas where hazardous processes or operations occur, in conformance with Article
8 National Fire Code Indoor Storage Fire Safety Plan 1) A fire safety plan conforming to Section 2.8. and Sentences (2) and (3) shall be prepared 2) The fire safety plan shall identify a) the product classifications as described in Sentence (1) for each part of the building where products of different classifications are stored, b) the method of storage, including aisle widths for rack storage
9 Indoor Storage Cont. c) the maximum permitted height of storage for the building or part of the building, if different d) the maximum permitted size of individual storage areas, e) in sprinklered buildings, the sprinkler system design criteria, inside and outside hose allowances, and results of the benchmark sprinkler system main drain and water flow test
10 Outdoor Storage Fire Safety Plan 1) A fire safety plan conforming conforming to Section 2.8. And Sentences (2) and (3) shall be prepared. 2) The fire safety plan required in Sentence (1) shall identify a) the location and classification of the products currently stored, as described in Sentence (1)
11 Outdoor Storage (cont.) b) the method of storage, including the clear spaces required and the maximum size of individual storage areas, c) the location of fire alarm systems and fire fighting equipment and d) the control of fire hazards in and around the outdoor storage area. 3) At least one copy of the fire safety plan shall be prominently posted at the outdoor storage site
12 What Is A fire Safety Plan The purpose of a fire safety plan is to ensure effective utilization of fire and life safety features in a building. To provide efficient and safe evacuation of building occupants in the event of fire or other emergencies. To protect buildings and property from the incident of fire or the spread of fire from the area or room of origin
13 Owner Responsibilities The owner of a building responsible for preparation of the fire safety plan must ensure that the building and facilities comply with the fire code. With respect to fire safety the owner has numerous responsibilities, and must ensure the the following measures are included in the fire safety plan.
14 Audit of Building Resources Fire Alarm Systems Exit Locations Portable Fire Extinguishers Automatic Sprinkler Systems Emergency Power & lighting
15 Audit of Personnel The size of the organization and the number of personnel need to carry out the requirements of the Fire Safety Plan will depend on the size of the building, specific hazards and the fire safety equipment / systems provided.
16 Responsibilities of Supervisory Staff Be In Complete Charge of the Approved Fire Safety Plan Designate and Train a Sufficient number of Assistants to Act in the Absence of Regular Supervisory Staff
17 Key Areas of Concern Maintenance of Fire and Life Safety Equipment Seasonal Maintenance of Exits & Exit Stairs House Keeping of Storage or Work / Manufacturing Areas Ensure All Personnel are Aware of the Fire Safety Plan
18 Mandatory Maintenance Checks Daily : Check Green Power On LED Indicator Light For Fire Alarm System Monthly Check All Portable Fire Extinguishers, Emergency Power / Lighting Systems Check All Doors / Closures to Ensure they Close and latch as designed. Record all Maintenance Checks
19 Evacuation Planning Again the size of the organization, type of fire / life safety systems and number of personnel will impact on the evacuation plan It could be as simple as when the alarm goes you go.
20 The Fire Warden System Floor Wardens: Assigned to a particular floor area and responsible to ensure that persons in that area react to the fire alarm. May have other specific assigned duties. Persons with special needs Check remote section of their assigned floor area for people needing assistance to leave
21 Fire Drills NFC Fire Drill Procedures 1) The procedure for conducting fire drills shall be determined by the person in responsible charge of the building, by taking into consideration a) the building occupancy and it s fire hazards b) the safety features provided in the building c) the desirable degree of participation of occupants other than supervisory staff,
22 Fire Drills (cont.) d) the number and degree of experience of participating supervisory staff, e) the features of fire emergency systems installed in buildings within the scope of subsection of the National Building Code of Canada 1995, and f) the requirements of the fire department.
23 Fire Drill Frequency ) Fire drills described in sentence (1) shall be held at intervals not greater than 12 months for the supervisory staff, except that a) in day care centres and in Group B major occupancies, such drills shall be held at intervals not greater than one month b) in schools attended by children,total evacuation drills shall be held at least 3 times in each of the fall and spring school terms
24 Frequency Cont. c) in buildings within the scope of Subsection Of the National Building Code of Canada 1995, such drills shall be held at intervals not greater than 2 months.
25 Questions?
Important Ontario Fire Code Information for Building Owners in the City of Windsor
Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact
More informationCONSTRUCTION FIRE SAFETY PLANNING GUIDELINES
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.
More informationFIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589.
FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589 Bulletin 16-12 Fire Drills This guideline was developed to assist persons
More informationOFM-TG-01-2004. Office of the Fire Marshal F M FIRE DRILLS GUIDELINE
O FIRE DRILLS F M October 2004 GUIDELINE TABLE OF CONTENTS SECTION PAGE Abstract... 3 1.0 INTRODUCTION... 4 2.0 DEFINITIONS... 4 3.0 LEGAL OBLIGATIONS... 5 4.0 FIRE DRILL OBJECTIVES... 5 5.0 FIRE DRILL
More informationALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More informationAn inventory of hazardous materials used in your workplace will prove useful.
Introduction Fire Protection is an organized approach designed to prevent fires. In the event of a fire, a fire protection program will help prevent or minimize personal injuries, losses, and harm to the
More informationExit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection OSHA Office of Training and Education 1 Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers
More informationOverview of Hotel Fire Safety Requirements
Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined
More informationFire Risk Assessment Safety Checklist
Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory
More informationEducational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application
February 2014 Code Requirements and Inspections in Educational Occupancies Presented By: Barry W. Rickert Douglas M. Schanne Fire Marshal Training Program Supervisor Office of Education & Data Management
More informationThe terms hazard and risk are often used, which we define as the following:
Fire Safety Last updated in October 2010 This information sheet aims to give safety reps a basic understanding of fire safety and fire risk assessments under the current law. More detailed information
More information1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;
Fire Action Plan FIRE ACTION PLAN SEStran aims to provide and maintain safe & healthy working conditions, equipment and systems of work for all our employees, and to provide such information, training
More informationc. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.
Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent
More informationFire Safety Risk Assessment Checklist for Residential Care Premises
Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or
More informationBastille Court 2 Paris Garden London SE1 8ND Telephone: 020 7902 5314 Fax: 020 7902 5301 E-mail: training@thefpa.co.uk Web: http://www.thefpa.co.
Bastille Court 2 Paris Garden London SE1 8ND Telephone: 020 7902 5314 Fax: 020 7902 5301 E-mail: training@thefpa.co.uk Web: http://www.thefpa.co.uk Fire Risk Assessment Course Health & Safety at Work Inspectorate,
More informationFIRE SAFETY RECORD OF TESTS LOGBOOK
FIRE SAFETY RECORD OF TESTS LOGBOOK PREMISES ADDRESS: Responsible person AN INTRODUCTION TO YOUR LOG BOOK The Regulatory Reform (Fire Safety) Order 2005 requires the responsible person for a premises to
More informationFire Safety Risk Assessment
1 Sources of ignition The main sources of ignition in Cass building are: PAF arrange for the fixed electrical installation to be tested in accordance with the British Standards. Test certificates are kept
More informationUCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS
Fire Safety Technical Guide UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS 1.0. BACKGROUND 1.1. The Regulatory Reform (Fire Safety) Order (known Fire Safety Order) applies to England and Wales (Northern
More informationGeneral Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
More informationBerkeley Castle. Occupant Fire Safety
BERKELEY CASTLE 2 Berkeley Street, Suite 100, Toronto, Ontario, M5A 4J5 (Phone) 416-366-3704 (Fax) 416-366-3857 www.berkeleycastle.ca Berkeley Castle Occupant Fire Safety OCCUPANT FIRE SAFETY RESPONSIBILITIES
More informationFLA S FIRE SAFETY INITIATIVE
Improving Workers Lives Worldwide FLA S FIRE SAFETY INITIATIVE Preventing fires and saving lives by empowering workers and factory managers SCENARIO 1 OCCURS AT FACTORY ABC, WHICH HAS NOT IMPLEMENTED NECESSARY
More informationGuidance Document on Fire Safety Signs and Notices FIA Guidance for the Fire Protection Industry
Guidance Document on Fire Safety Signs and Notices FIA Guidance for the Fire Protection Industry This Guidance Note is intended as a general guidance and is not a substitute for detailed advice in specific
More informationFIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
More informationWe hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.
September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify
More informationEMERGENCY PLANS FACT SHEET
EMERGENCY PLANS FACT SHEET Overview This fact sheet provides general guidance for persons conducting a business or undertaking (PCBUs) and workers on preparing and maintaining general emergency plans for
More informationThe Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services
MITT ROMNEY GOVERNOR KERRY HEALEY LT. GOVERNOR EDWARD A. FLYNN SECRETARY The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services P.O. Box 1025 State Road Stow, Massachusetts
More informationSCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST
SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST School Name: School Address: Town: Phone: Inspected By (Please Print): Inspection Organization Name: Inspector Phone: Date of Inspection: Building Name:
More informationOntario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
More informationFire Safety Requirements for Child Care Centre
Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,
More informationFIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the
More informationBUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS
BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS Owners have numerous responsibilities as it pertains to the maintenance and operation of a building s fire safety equipment. The liabilities
More informationFIRE SAFETY INFORMATION FACT SHEET
Disclaimers: This information was believed to be correct at the date of its publication. This information is for general information purposes only and should not be relied upon for legal advice. FIRE SAFETY
More informationCAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau
CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau g GUIDELINE FOR SAFETY REQUIREMENTS FOR HAUNTED HOUSES PURPOSE This guide is intended to provide safety standards and regulations for the construction
More informationHow To Write A Fire Risk Assessment
Fire Safety Risk Assessment This form is to aid you in carrying out a fire safety risk assessment of a property. The form is separated in to two parts: Part 1 initial assessment form and guidance notes
More informationCITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY
CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY This policy was written in July 2014 and will be agreed by the Board of Governors in October 2014. To be reviewed by June
More informationHow To Build A Two Hour Firewall In Calgary
BUILDING CODE INTERPRETATION February 2008 06-BCI-005-R1 Page 1 of 6 TWO-HOUR FIREWALLS BACKGROUND Historically, firewalls used to subdivide buildings into smaller units have been built using one of two
More informationFire Safety PROCEDURES January 2011
Fire Safety PROCEDURES January 2011 firesafety@uwo.ca Campus Phones EMERGENCY Dial 911 Fire Safety Service is the focal point for the coordinated administration of the University Fire Safety program and
More informationFire Evacuation Procedures Network Building, 97 Tottenham Court Road, London, W1
Network Building Fire Safety Management Plan & Fire Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of Fire 4.0 Means for Fighting
More informationFIRE SAFETY RISK ASSESSMENT
FIRE SAFETY RISK ASSESSMENT For small single occupancy premises Premises Hertco Ltd ACME House, Old London Road, Hertford SG17 7LD Fire Safety Risk Assessment for Small Premises Introduction Regulatory
More informationEMERGENCY PREPAREDNESS & RESPONSE PROCEDURE
1 of 12 DOCUMENT REVISION HISTORY Revision No. Date DESCRIPTION OF CHANGES Pages Affected By 00 01/07/2003 Draft Issued For Comment All HSEQ Dept. 01 01/09/2003 Total Change First Approved Issue All HSEQ
More informationNEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rules
NEW YORK CITY FIRE DEPARTMENT Notice of Public Hearing and Opportunity to Comment on Proposed Rules What are we proposing? The Fire Department is proposing to amend two rules. One relates to Fire Department
More informationIndiana Building Rehabilitation Standard
Rule 8. Indiana Building Rehabilitation Standard 675 IAC 12-8-1 Definitions Sec. 1. The following definitions apply throughout this rule: (1) "Building code" means the Indiana Building Code under 675 IAC
More informationCh. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT
Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE Sec. 58.1. Division D-O occupancies. 58.2. Separation and mixed occupancy. OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM
More informationREGULATORY REFORM (FIRE SAFETY) ORDER 2005. Fire Risk Assessment. 145 Drury Lane Covent Garden London WC2B 5TA
REGULATORY REFORM (FIRE SAFETY) ORDER 2005 Fire Risk Assessment 145 Drury Lane Covent Garden London WC2B 5TA Annex A (informative) Model pro-forma for documentation of the fire risk assessment for premises
More informationErrata has been identified as follows:
2009 IFC Performing Commercial Fire Inspections Inventory Number: 1424S09 Second Printing; July 2014 Changes HAVE been made- Third Printing: September 2014 Errata has been identified as follows: 1. Page
More informationFIRE EVACUATION PLAN. School of Mathematics & Statistics
FIRE EVACUATION PLAN School of Mathematics & Statistics Herschel Building (July 2014) FIRE EVACUATION PLAN School of Mathematics & Statistics Fire Safety Housekeeping Fire doors are designed to prevent
More informationTYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
More information1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS
Fire Risk assessment 1.0 APPOINTMENTS 1.1 Responsible Person. In compliance with the Regulatory Reform (Fire Safety) Order 2005 (FSO) the School s Head, Mrs J M Miles is appointed as the Responsible Person
More informationFIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS The attached self-inspection form is intended for staff use at regular, frequent intervals. It should not take the place of two other vital measures
More informationUPP Residential Services Fire Risk Assessment
UPP Residential Services Fire Risk Assessment TS11151-R02-DRAFT1 15 August 2011 for: Keynes College University Road Canterbury Kent Recommended latest review date 14 August 2011 Executive summary This
More informationEnvironment of Care Fire Safety Management Plan 2014
Environment of Care Fire Safety Management Plan 2014 Updated 4.29.2014 PURPOSE The purpose of the Fire Safety Management Plan is to ensure that all facilities are designed, constructed, maintained, and
More informationFIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No
General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency
More informationCJ s health and Safety Law poster is displayed in the staff lobby.
Introduction has a responsibility to ensure that Health and Safety of all it employees while at work. We aim to fulfil these responsibilities by taking steps to work in accordance with relevant Health
More informationOntario Association of Fire Chiefs Position Paper Residential Fire Sprinklers
Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers The Ontario Association of Fire Chiefs (OAFC) supports changes to the Ontario Building Code to require that all new residential
More informationRBC CENTRE 155 WELLINGTON STREET WEST TORONTO, ONTARIO
RBC CENTRE 155 WELLINGTON STREET WEST TORONTO, ONTARIO Date: May 1, 2013 LRI 2013 TABLE OF CONTENTS GENERAL INFORMATION... 1 FIRE SAFETY PLAN... 7 FIRE SAFETY TEAM ORGANIZATION... 8 FIRE WARDENS... 9 PERSONS
More informationFlammable Liquids Storage
A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario
More informationFire Alarm Log Book. Any activity regarding this system must be documented in writing.
CASTLE ROCK FIRE AND RESCUE DEPARTMENT 300 Perry Street Castle Rock, Colo. 80104 303-660-1066 Do not remove from the premises: Fire Alarm Log Book Any activity regarding this system must be documented
More informationFIRE RISK ASSESSMENT. The Workplace Fire Precautions Legislation
FIRE RISK ASSESSMENT The Workplace Fire Precautions Legislation The Fire Precautions (Workplace) Regulations 1997 The Fire Precautions (Workplace)(Amendment) Regulations 1999 The Management of Health and
More informationGrasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment
Grasshoppers Rugby Football Sports and Social Club The Fire Risk Assessment Revision 1 Dated: 15th February 2013 CONTENTS 1. PREMISES DETAILS 2. PREMISES PLAN 3. HAZARDS 4. HISTORY 5. MITIGATING THE EFFECTS
More informationLee Baron FIRE RISK ASSESSMENT
FIRE RISK ASSESSMENT, 13/21 Cantelupe Road, East Grinstead Prepared for: Lee Baron 7 Swallow Place Oxford Circus London W1B 2AG Prepared by: Violet McIntyre CMIOSH William Martin Compliance Solutions Limited
More informationWorkplace Fire Safety
Teaching Guide Workplace Fire Safety for staff Seattle Fire Department Fire Prevention Division Workplace Fire Safety Instructor Outline Introduction Goals: To ensure that employees are knowledgeable in
More informationPART 1 FIRE SAFETY PLAN
Fire Safety Plan This sample fire safety plan has been developed to help owners and managers of small apartment buildings maintain compliance with Section 2.8 of the B.C. Fire Code. The plan is intended
More informationFire Safety Log Book
Fire Safety Log Book Company... Address........ Responsible Person. Competent Person. Date Started For Additional Information: Safety Management (UK) Ltd Holme Suite, Clawthorpe Hall Business Centre, Burton
More informationHow To Check If A Building Is Safe For A Disabled Person
GENERAL SAFETY-FIRE-SECURITY SURVEY CHECKLIST CAMPUS INSPECTION DATE BUILDING NAME INSPECTOR: ASSISTED BY: OUTSIDE/INSIDE BUILDING 1. ADA (Americans with Disabilities Act) Entry/Exit (If area is designed
More informationEMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the
More informationQuantum Risk Management Ltd t/a Quantum Compliance 23 Hanover Square, London W1S 1JB 34 Greenbox, Westonhall Road, Stoke Prior B60 4AL T:0800 644
Contents Accident Investigation and Prevention 3 Asbestos Awareness 4 BOHS 901 Legionella - Management and Control of Building Hot and Cold Water Systems 5 BOHS 903 Legionella - Management and Control
More informationHealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids
Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario Fire Code, Part 4, and of the Regulations for
More informationFire Safety Report 2014. Fire Protection Management Program and Annual Fire Safety Report on Student Housing
Fire Safety Report 2014 Fire Protection Management Program and Annual Fire Safety Report on Student Housing New Jersey City University 2039 Kennedy Boulevard Jersey City, NJ 07305 The following link is
More informationFIRE ESCAPE SIGNS Guidance on compliance
FIRE ESCAPE SIGNS Guidance on compliance Document control information Published document name: escapesigns-gn.pdf, Date issued: January 2011 Version: 2.0 Previous review dates: 2011 Next review date: Related
More informationDecree of the Ministry of the Environment. on fire safety of garages
E4 THE NATIONAL BUILDING CODE OF FINLAND Fire safety of garages Guidelines 2005 Decree of the Ministry of the Environment on fire safety of garages Adopted in Helsinki, 22 March 2005 Pursuant to the Decision
More informationTexas Department of Insurance. Fire Safety. Provided by. Workers Health & Safety. Pub. No. HS01-028D (7-08)
Texas Department of Insurance Provided by Workers Health & Safety Pub. No. HS01-028D (7-08) A fire safety plan is an essential part of any workplace safety program. In fact, the Occupational Safety and
More informationFire Safety Challenges and Solutions. Claire Guise Health and Safety Manager
Fire Safety Challenges and Solutions Claire Guise Health and Safety Manager Marie Curie Cancer Care (UK Wide) 9 Palliative Care Hospices (owned) Facilities Manager in place (NEBOSH General Certificate
More informationFACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
More informationINTERNATIONAL FIRE CODE SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES
INTERNATIONAL FIRE CODE SECTION 3103 TEMPORARY TENTS AND MEMBRANE STRUCTURES 3103.1 General. All temporary tents and membrane structures shall comply with this section. 3103.2 Approval required. Tents
More informationBenchmark OHS Consulting Pty Ltd Self Assessment WHS Audit Tool
Benchmark OHS Consulting Pty Ltd Self Assessment WHS Audit Tool This WHS Auditing System Tool is to be used as a self-assessment of YOUR COMPANY compliance with AS 4801 and the Work Health and Safety Act
More informationFIRE RISK ASSESSMENT
REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT This template has been provided to assist the Responsible Person with the preparation of a Fire Risk Assessment and is not intended for commercial
More informationPLAN REVIEW GUIDE FOR FIRE ALARM
PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical
More informationNY Fire Safety Institute
NY Fire Safety Institute Presents the FDNY Coordinator of Fire Safety and Alarm Systems Homeless Shelters (Premise Related) Certificate of Fitness F-80 Definitions and Terminology Established 1995 Preparing
More informationFIRE RISK ASSESSMENT WORKED EXAMPLE
FIRE RISK ASSESSMENT WORKED EXAMPLE 1 PREMISES PARTICULARS BE-INT05 Premises Name S M Enterprises Address Small Place Medium Road Anywhere Tel no: 01234 567890 Date of Risk Assessment 1 st July 2011 Use
More informationFire & Safety. Fire Safety Training For FHSc Staff and Students in Health Care Facilities
Fire Safety Training For FHSc Staff and Students in Health Care Facilities Staff must know how to respond to a Fire Emergency Actions to take upon discovering a fire Actions to take upon hearing the fire
More informationESTABLISHMENT OF A NEW BUSINESS
ESTABLISHMENT OF A NEW BUSINESS ATTENTION BUSINESS OWNERS Certificate of Occupancy Permit Requirements & Application Prior to any materials associated with your business being moved into the property that
More informationPOLICY ON HEALTH AND SAFETY (GENERAL)
POLICY ON HEALTH AND SAFETY (GENERAL) General Statement It is the policy of Serenity Homecare Limited to ensure, so far as is reasonably practicable, the health, safety and welfare of its employees and
More informationCITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN
CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN DATE PROPERTY MANAGER ADDRESS Houston, TX _(Zip Code)_ PHONE NUMBER LIFE SAFETY IS THE GOAL OF THIS PLAN. ALL DUTIES CALLED FOR HEREIN SHOULD
More informationFire risk assessment a guide for businesses
Fire risk assessment a guide for businesses Disclaimer Cornwall Fire and Rescue Service provide this guide to assist businesses to improve fire safety in their premises, but stress the person completing
More informationFlammable Liquids Storage
A Health and Safety Guideline for Your Workplace Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario
More informationBUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS
DCD-0304 Identification # Rev. 9/08 County Date of Inspection NAME OF OPERATION BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS ADDRESS TELEPHONE: CITY STATE ZIP BUILDING INSPECTORS CERTIFICATE
More informationNew Ontario Building Code Requirements for Mid-rise Wood Frame Buildings
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the
More informationFLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes
FLAMMABLE AND COMBUSTIBLE LIQUIDS OSHA Changes Introduction This module covers the two primary hazards associated with flammable and combustible liquids: explosion and fire. In order to prevent these hazards,
More informationQueen's University Environmental Health and Safety
April, 2009 1 SOP-Chem-08 1.0 Introduction This document is intended as a guide to the Queen s University requirements for handling and storing flammable and combustible material in non-laboratories areas.
More informationFire Policy and Procedures. Cañada Blanch Spanish School
Fire Policy and Procedures Cañada Blanch Spanish School SUMMARY 1. Introduction (p. 3) 2. Roles and responsibilities (p. 3) -- Headteacher -- Fire Team -- All staff -- Contractors 3. Fire procedures (p.
More informationOCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.
1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310
More information(Sample) Building Emergency Plan
(Sample) Building Emergency Plan for XXXXXX 2815 Commons Way Cincinnati, OH 45221 August 2016 University of Cincinnati Department of Public Safety Department a 2 Table of Contents A. Introduction B. Components
More informationMEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: MEANS OF EXIT / ESCAPE / EGRESS Guidelines: This checklist covers some of the regulations
More informationFire Risk Assessment. John Revington
Fire Risk Assessment John Revington PRACTICAL APPLICATION Identifying Fire Hazardsand Managing Fire Precautions History of Fire Fires that have changed our lives History of Fire Theatre Royal - Exeter
More informationThe University of Texas at San Antonio Environmental Health, Safety and Risk Management
The University of Texas at San Antonio Environmental Health, Safety and Risk Management TO: FROM: UTSA Campus Community John DeLaHunt, MBA, ARM Risk & Life Safety Manager University Fire Marshal J. Brian
More informationIr. NOORAZMAN BIN SOUD. Deputy Director Petroleum Safety Division
Ir. NOORAZMAN BIN SOUD Deputy Director Petroleum Safety Division 1 OUTLINES Introduction of DOSH Classification of CIMAH 1996 What is ERP? Objectives of ERP Why need ERP? Types of ERP Onsite ERP Components
More informationFire Risk Assessment For Simple Premises
Fire Risk Assessment For Simple Premises Responsible Person (Employer or other person having control of the relevant premises) Company / Premises Name Address of Premises Postcode Primary Use of Premises
More informationEmergency Evacuation Plan: 232 King St.
Emergency Evacuation Plan: 232 King St. Effective Date: July 2003 Revisions: 0 Approved on: April 20, 2004 Table of Contents 1.0 Building Resources... 1 2.0 Human Resources... 2 3.0 Definitions... 3 4.0
More information