Specifications for a Trailer Mounted 60 kw Three Phase Portable Generator

Size: px
Start display at page:

Download "Specifications for a Trailer Mounted 60 kw Three Phase Portable Generator"

Transcription

1 Specifications for a Trailer Mounted 60 kw Three Phase Portable Generator The Trailer Mounted Generator covered by these specifications will be used primarily by the Northwest Wastewater Treatment Plant as back up power for City Sewage Lift Stations. If the Equipment proposed by the Bidder does not meet or exceed the specification(s) listed herein, the Bidder shall note in detail the deviations in the space(s) provided. The generator and trailer shall be equipped to comply with all applicable Federal and State OSHA requirements. Generator Features Brushless alternator for long life, low maintenance Yes No Voltage regulation ½% Yes No 60 Hertz frequency Yes No Industrial grade Tier 3 Engine Yes No Air Intake Heater Yes No Fuel/Water separator Yes No Electronic Governor Yes No Digital Controller with automatic safety shutdowns and digital readouts for: Low oil pressure Yes No High water temperature Yes No Engine over-crank Yes No Engine over-speed Yes No Low fuel level shutdown (user select) Yes No Controller disconnect switch Yes No Voltage adjust potentiometer Yes No Illuminated Instrumentation Panel Yes No Main Circuit breaker for main power connection Yes No Circuit breakers for single phase receptacles Yes No Single phase receptacles are powered during all main voltage configurations Yes No Heavy gauge steel sound attenuated enclosure with: Internally mounted muffler Yes No Durable powder coat paint finish Yes No Pad lock-able doors Yes No

2 Single point lifting eye Yes No Long run, internal, single wall XLPE fuel tank Yes No 6 bolts to remove generator from trailer Yes No Standard Premium grade DOT approved tandem axle highway trailer featuring: Torsion bar suspension Yes No Diamond plate aluminum fenders Yes No Front leveling jack Yes No Running lights Yes No Hydraulic brakes Yes No Lighted license plate bracket Yes No 2" ball hitch coupling Yes No Battery included Yes No Limited 3 year Warranty 1 year or 3,000 hours parts and labor Yes No 3 year or 3,000 hours parts Yes No Options to be included: Block Heater Yes No Battery Charger Yes No Shore power inlet for easy connection to block heater or battery charger Yes No Electric Brakes Yes No Automatic transfer switches Yes No Battery Disconnect Yes No Spark Arrestor Muffler Yes No Permanent Magnet Gen Yes No Voltage Adjustment Potentiometer Yes No Generator Specifications - Preliminary Standby Output 150 C Rise kva/kw Single 240V 45/45 Yes No 3 208V 74/59 Yes No 3 240V 80/64 Yes No 3 480V 80/64 Yes No

3 Prime Output 125 C Rise kva/kw Single 208V 41/41 Yes No 3 240V 67/54 Yes No 3 480V 73/58 Yes No Amperage (Standby Rating) Amps Single phase 240/120V 17/2X187 Yes No 3 phase 208V 205 Yes No 3 phase 240V 192 Yes No 3 phase 480V 96 Yes No Voltage - 3 phase adjustable 208/220/240/416/440/460/480 Yes No Voltage-Single phase adjustable 120/127/139/240/254/277 Yes No 3 phase Power Factor.8 Yes No Voltage Regulation ½% Yes No Frequency 60 Hertz Yes No Total Harmonic Distortion <5% Yes No Insulation Class H Yes No Engine Specifications Cylinders 4 Yes No Induction System Turbocharged, Charge Air Cooled Yes No Displacement, L (cu. in) 4.5L (275) Yes No EPA Emissions Level Tier 3 Yes No rated speed 99 Yes No RPM 1800 Yes No Bore and stroke 4.2" x 5.0" Yes No Lubrication capacity (with filter) 13.9 Qts Yes No Battery recommendation (min. cold cranking amps) 925 Yes No Battery, battery rack and cable supplied Yes No Spin on oil filter Yes No Thermostat controlled liquid cooling system Yes No 12V engine alternator Yes No

4 12V starter motor Yes No Receptacle Specifications 120 Volt 20 Amp Duplex GFCI 3 Yes No 120/240 Volt 50 Amp Twistlock 3 Yes No Two wire remote start capability Yes No Fuel System Specifications Fuel consumption Standby Rating GPH ½ load 3.1 Yes No Full load 6.3 Yes No Approximate Run Time Hours ½ load 32 Yes No Full load 16 Yes No Fuel Capacity Gallons Fuel Diesel Yes No Weights and Dimensions Weight without fuel Weight without fuel and without trailer Dimensions with trailer ( L x W x H) Dimensions without trailer (L x W x H) Sound Level Sound level db(a) 67 Yes No 7 meters, full load Yes No Other Features Start/Stop/Auto Switch Yes No Alarm Horn Yes No Controller Disconnect Switch Yes No Trailer Side Markers and Running Lights Yes No

5 Literature (Delivery is not complete without Literature): Operations - Manual of operator instructions covering operating Yes No procedures of Generator and Trailer Parts - Book with comprehensive listing of all parts for Generator and Trailer Yes No Service - Manual of proper mechanical maintenance procedures Yes No required to assure proper operation and life. Delivery Generator and Trailer - FOB Carbondale Northwest Wastewater Treatment Plant, 1699 New Era Road Yes No Delivery - Days from Award (stipulate) Days Parts and Service Service Location - Number of miles from Northwest Wastewater Treatment Plant 1699 New Era Road (stipulate) Miles

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) RENTAL Standby Prime Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) Shown with optional trailer FEATURES EPA TIER 4 AND CARB CERTIFIED

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES XQ230 SOUND ATTENUATED DUAL VOLTAGE 50/60 Hz Arrangement shown with optional trailer FEATURES EMISSIONS EPA Tier 3 and CARB Emissions Certified for non-road mobile applications at all 60 Hz and 50 Hz ratings

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw ,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted

More information

Diesel Generating Set

Diesel Generating Set MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V

More information

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Standard Features 3 Cylinder Diesel Engine for maximum durability, reliability and efficiency. Brushless alternator

More information

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 50HZ MP Series MPS180S 1 / MPS180 1 MPS180S 1 / MPS180 1 MP Series Features Compact structure with high strength chassis; Easy operation and maintenance,

More information

Spark-ignited generator set

Spark-ignited generator set Specification sheet Spark-ignited generator set 30 60 kw standby EPA emissions Description Cummins Power Generation commercial generator sets are fully integrated power generation systems providing optimum

More information

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 60HZ MC Series MCS600S-2 / MCS600-2 MCS600S-2/ MCS600-2 MC Series Features Reference images, the actual shall prevail Compact structure with high-strength

More information

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T O R S E T GEP550 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET Complete system designed and built at ISO9001 certified facility Factory

More information

APS100 Rental Generator Set Specification

APS100 Rental Generator Set Specification BARTONVIE * CEDAR RAPIDS * DAVENPORT * EAST PEORIA * HANNIBA * MOBERY * ROCK FAS * SPRINGFIED * URBANA APS100 Rental Generator Set Specification STANDBY 100 kw 60 Hz/PRIME 90 kw 60 Hz FEATURES EPA TIER

More information

Frequently Asked Questions Generators

Frequently Asked Questions Generators Frequently Asked Questions Generators Fuel Related How much fuel do the generators use during normal operation? At exercise? The generator fuel consumption is given in each of the product knowledge books

More information

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance

More information

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered

More information

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered

More information

DIESEL GENERATOR SETS

DIESEL GENERATOR SETS DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete

More information

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET DIESEL SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are Tier II EPA

More information

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES: Standby Generators Liquid-Cooled Gas Engine 1 of 9 INCLUDES: Two Line LCD Tri-Lingual Digital Nexus Controller Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System

More information

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES Factory designed, certified prototype tested with torsional analysis. Production tested and delivered in a package that is ready

More information

Auxiliary Power Unit (APU) for Military Vehicles

Auxiliary Power Unit (APU) for Military Vehicles Auxiliary Power Unit (APU) for Military Vehicles Jeff Humble General Dynamics Land Systems 640 Seminole Rd. Muskegon, Michigan 49441 (231)780-5609 humblej@gdls.com Page 1 APU Program Summary Developed

More information

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS PUMP MAINTENANCE SCHEDULE AND CHECKLISTS Providing a maintenance schedule defined specifically by run hours or yardage pumped serves only as a general guideline given the large amount of variables a unit

More information

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 800 ekw 1000kVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,

More information

Atlas Copco Generators

Atlas Copco Generators Atlas Copco Generators QIX 15 - QIX 540 16 kva LTP to 549 kva LTP at 50 & 60 Hz The QIX options include Earth leakage relay Qc generating set control panels for all standby and/or paralleling applications

More information

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T I N G S E T GEP150 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 150 kva / 120 kw 135 kva / 108 kw 165 kva / 132 kw 150 kva / 120 kw FEATURES GENERATING SET Complete system

More information

307E. Mini Hydraulic Excavator. Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo. Weights

307E. Mini Hydraulic Excavator. Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo. Weights 307E Mini Hydraulic Excavator Bucket Engine Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo Net Power 41.5 kw (55.6 hp) Gross Power @ 2,000 rpm 43 kw (57.6 hp) Weights Operating Weight 6800

More information

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals. 600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw

More information

C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm

C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression

More information

Annex-A TECHNICAL SPECIFICATION

Annex-A TECHNICAL SPECIFICATION Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery

More information

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

A reasonable, new furnace (mid efficiency) has the following electrical requirements: June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,

More information

Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1 K3 WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor

More information

LOAD BANK TESTING PROCEDURE

LOAD BANK TESTING PROCEDURE LOAD BANK TESTING PROCEDURE APPENDIX G SPS-G-1 of 9 I. General GENERATOR LOAD BANK TESTING AND ENGINE TESTING A. Provide all equipment, labor, materials and supervision necessary to test the stand-by diesel

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8 SILENT PACK AIR-COOLED SINGLE PHASE 60 HZ INT. TIER IV DIESEL Generating Rates SERVICE PRP STANDBY Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power

More information

6-years/75,000 miles Comprehensive coverage Subsequent Owner Warranty $100 Deductible

6-years/75,000 miles Comprehensive coverage Subsequent Owner Warranty $100 Deductible LINCOLN PREMIER LIMITED WARRANTY 6-years/75,000 miles Comprehensive coverage Subsequent Owner Warranty $100 Deductible Comprehensive Coverage Because Lincoln has always been a brand you can trust and respect,

More information

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater. Diesel Truck Engine 3126B 175-330 hp 420-860 @ 1440 rpm Peak CATERPILLAR ENGINE SPECIFICATIONS 6-Cylinder, 4-Stroke-Cycle Diesel Bore in (mm)... 4.33 (110) Stroke in (mm)... 5.0 (127) Displacement cu in

More information

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com. IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation

More information

How To Use A Cat Diesel Engine

How To Use A Cat Diesel Engine DIESEL GENERATOR SET STANDBY 440 ekw 550 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical Specification. Generating Set with Waukesha engine burning natural gas Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the

More information

STANDBY PERMANENT MOUNT SERIES GENERATOR

STANDBY PERMANENT MOUNT SERIES GENERATOR PRESENTS YOUR STANDBY PERMANENT MOUNT SERIES GENERATOR OPERATORS MANUAL BALDOR GENERATORS 3815 OREGON STREET OSHKOSH, WI 54902 PHONE: 920-236-4200 FAX: 920-236-4219 FORM#: S-PSG-002-91 REVISED: 2/25/02

More information

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw CAT NEXT GENERATION DIESEL GENERATOR SETS C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw THE NEXT GENERATION CAT DIESEL GENERATOR SET FEATURES SEVERAL KEY DESIGN AND PERFORMANCE ENHANCEMENTS TO ITS

More information

11,000 kg, 13,000 kg, 16,000 kg Diesel, Pneumatic Tire

11,000 kg, 13,000 kg, 16,000 kg Diesel, Pneumatic Tire R Pneumatic Diesel Forklift Trucks D110/130/160S-5 11,000kg to 16,000kg Capacity D110 / 130 / 160S-5 11,000 kg, 13,000 kg, 16,000 kg Diesel, Pneumatic Tire Printed in Repubic of Korea PSC2604D0(Feb.2007)

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

Midwest Industrial Tanks

Midwest Industrial Tanks FOR AGRICULTURE AND INDUSTRY Midwest Industrial Tanks Fuel & Oil Storage Solutions Midwest Industrial Tanks Is Your Source For All Of Your Fuel Storage And Fuel Transportation Needs. Our Satisfied Customers

More information

START A REVOLUTION! THE NEW SULLAIR 185 PORTABLE AIR COMPRESSOR.

START A REVOLUTION! THE NEW SULLAIR 185 PORTABLE AIR COMPRESSOR. START A REVOLUTION! THE NEW SULLAIR 185 PORTABLE AIR COMPRESSOR. THE NEW SULLAIR 185 CFM PORTABLE AIR COMPRESSOR IS CREATING A REVOLUTION. Sullair Construction Products continues the revolution we started

More information

The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities

The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities Generator Testing in Nursing Facilities Introduction Recent emergencies and natural disasters have emphasized the need to ensure that nursing facilities have an adequate EPSS in place should the loss of

More information

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption IE DIESEL FEATURES GENERATOR SET PRIME 2000 ekw 2500 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability,

More information

3516 Industrial Engine

3516 Industrial Engine CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle Diesel Bore...170.0 mm (6.69 in) Stroke...190.0 mm (7.48 in) Displacement... 69.06 L (4,214.3 in 3 ) Aspiration...Turbocharged / Aftercooled Compression Ratio...13.0:1

More information

Wynn s Extended Care

Wynn s Extended Care Wynn s Extended Care Every car deserves to receive the very best care... especially yours. How Do You Keep Your Reliable Transportation Reliable? Count on Wynn s Because Wynn s has been caring for cars

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm Marine Auxiliary Engine SPECIFICATIONS 3304B 56 bkw (75 bhp) 100 mhp @ 1200 rpm Shown with Accessory Equipment I-4, 4-Stroke-Cycle-Diesel Emissions...IMO compliant Displacement... 7.0 L (425 cu. in.) Bore...

More information

PEACH PACKAGED ELECTRIC AIR CONDITIONING & HEATING PATENT PENDING FIRST RESPONDER EMERGENCY EQUIPMENT

PEACH PACKAGED ELECTRIC AIR CONDITIONING & HEATING PATENT PENDING FIRST RESPONDER EMERGENCY EQUIPMENT PEACH PACKAGED ELECTRIC AIR CONDITIONING & HEATING PATENT PENDING FIRST RESPONDER EMERGENCY EQUIPMENT Hurricanes Floods Tornados Ice Storms Hazardous Waste Disasters Earthquakes Fires = Power Outages Loss

More information

The 26 200 kva RAnge

The 26 200 kva RAnge The 26 200 kva Range The new 26 200 kva range...designed to Deliver More. We understand the unique needs of generating set customers around the world. Forty years experience combined with the latest technology

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

Power kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Power kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1 E10 (HIGH SPEED) WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Power Generation. Power Control PCL System Generator Set Control

Power Generation. Power Control PCL System Generator Set Control Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation

More information

Prime Power Services, Inc. Georgia, Carolinas 800 741 0128. NFPA 110 Standards for Emergency & Stand by Generators June 1, 2010

Prime Power Services, Inc. Georgia, Carolinas 800 741 0128. NFPA 110 Standards for Emergency & Stand by Generators June 1, 2010 Prime Power Services, Inc. Georgia, Carolinas 800 741 0128 NFPA 110 Standards for Emergency & Stand by Generators June 1, 2010 NFPA Disclaimer The views and opinions expressed in this seminar are purely

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

How To Control A Power Command Powerplant

How To Control A Power Command Powerplant Diesel Generator Set Model DFEJ 60 Hz EPA Emissions 450 kw, 563 kva Standby 410 kw, 513 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power

More information

Specifications for Volkswagen Industrial Engine

Specifications for Volkswagen Industrial Engine Volkswagen 1 industrial engine Specifications for Volkswagen Industrial Engine AFD 1.9 ltr. TDI diesel engine EURO 2 Volkswagen AG, Wolfsburg Volkswagen AG reserves the right to introduce amendments or

More information

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO D10 WATER-COOLED THREE PHASE 50 HZ STAGE 2 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 100 107 Power kw 79 86 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 230-230/132

More information

General Dimensions and Weights - Non Loader

General Dimensions and Weights - Non Loader Home > Equipment > Tub Grinders > TG5000 TG5000 Specs General Dimensions and Weights - Non Loader Maximum Length - Transport 39.2' 12 m Maximum Length - Conveyor Unfolded 61.1' 18.6 m Maximum Width (Transport)

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

New 27 hp 2 Cylinder Liquid-Cooled Engine

New 27 hp 2 Cylinder Liquid-Cooled Engine New 27 hp 2 Cylinder Liquid-Cooled Engine Introducing the new 27 hp Liquid-Cooled Vanguard 2/LC Engine A cooler, smoother, longer running commercial engine. That s the liquid-cooled advantage of the Vanguard

More information

The Yachtmans Choice...

The Yachtmans Choice... Ref: 1740, Nov 2015 The Yachtmans Choice... A competitive price 10 to 150 hp, engineered in the UK Advanced, compact, quiet reliable engines Easy engine replacement, with our special feet option Amazing

More information

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min. www.kaeser.com

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min. www.kaeser.com Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min www.kaeser.com Made in Germany KAESER s renowned MOBILAIR range of portable compressors is

More information

POWERING THE WAY Rental Power Planner

POWERING THE WAY Rental Power Planner POWERING THE WAY Rental Power Planner PLANNING FOR TEMPORARY POWER: A Critical Management Duty As a facility manager, you know better than anyone that electrical power is the lifeblood of business. Without

More information

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES

More information

304.5. Mini Hydraulic Excavator

304.5. Mini Hydraulic Excavator 304.5 Mini Hydraulic Excavator Cat 3024 Naturally Aspirated Diesel Engine Flywheel Power 28 kw 38 hp Operating Weight: With cab 4595 kg 10130 lb With canopy 4475 kg 9866 lb 304.5 Mini Hydraulic Excavator

More information

Marine Generating Sets 3.7 to 50 kva

Marine Generating Sets 3.7 to 50 kva Marine Generating Sets 3.7 to 50 kva The Marine Engineer s Preference BetaSet - Standard Marine Generators Beta Marine has considerable experience from over twenty years of manufacturing marine generating

More information

Petrol engines. Technical specifications 1.4 MPI/59kW 1.6 MPI/75 kw 1.6 MPI/75 kw Engine

Petrol engines. Technical specifications 1.4 MPI/59kW 1.6 MPI/75 kw 1.6 MPI/75 kw Engine ŠKODA Octavia Tour Petrol engines Technical specifications 1.4 MPI/59kW 1.6 MPI/ kw 1.6 MPI/ kw Engine Engine type petrol engine, in-line, liquid cooling system, DOHC, transverse in front petrol engine,

More information

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption DIESEL GENERATOR SET STANDBY 560 ekw 700 kva Caterpillar is leading the power generation market place with power solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Power Take-Off Generators

Power Take-Off Generators Power Take-Off Generators PTO Generators, 15 kw 100 kw Single & Three Phase PTO Carts & PTO Shafts Two Five Year Limited Warranty Represented By: Viking Power Products Co. PO Box 127 Lewisville, PA 19351

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Packages Applicable to the following models: 600-1000REOZM Kohler enclosures protect stationary generator sets from the elements,

More information

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFHC 60 Hz Diesel Generator Set Model DFHC 60 Hz 900 kw, 1125 kva Standby 818 kw, 1023 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

Diesel Generator Set Model DGDK 60 Hz

Diesel Generator Set Model DGDK 60 Hz Diesel Generator Set Model DGDK 60 Hz 125 kw, 156 kva Standby 113 kw, 141 kva Prime Description The Cummins Power Generation DG-series commercial generator set is a fully integrated power generation system

More information

ŠKODA Rapid Petrol engines

ŠKODA Rapid Petrol engines ŠKODA Rapid Petrol engines Technical specifications 1.2 MPI/55 kw 1.2 TSI/63 kw 1.2 TSI/77 kw 1.6 MPI/77 kw 1.6 MPI/77 kw (A) 1.4 TSI/90 kw (A) Engine Engine type turbocharged petrol petrol engine, in-line,

More information

C18 Diesel Oilfield Generator Set

C18 Diesel Oilfield Generator Set C18 Diesel Oilfield Generator Set 545 ekw (680 kva) 60 Hz 480 Volts 1800 rpm CATERPILLAR ENGINE SPECIFICATIONS C18 In-Line 6, 4-Stroke-Cycle water-cooled diesel Bore... 145 mm (5.71 in.) Stroke... 183

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

301.7D. Mini Hydraulic Excavator

301.7D. Mini Hydraulic Excavator 301.7D Mini Hydraulic Excavator Engine Weights Gross Power (ISO 14396) 17.9 kw 24.3 hp Operating Weight with Canopy 1610 kg 3,550 lb Net Power 13.2 kw 17.7 hp Operating Weight with Cab 1720 kg 3,792 lb

More information

SG080 9.0L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG080 80 kw. Standby Power Rating 80 kw 100 kva 60 Hz

SG080 9.0L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG080 80 kw. Standby Power Rating 80 kw 100 kva 60 Hz SG080 9.0L Industrial Spark-Ignited Generator Set EPA Certified Stationary Emergency SG080 80 kw Power Rating 80 kw 100 kva 60 Hz Prime Power Rating* 72 kw 90 kva 60 Hz *EPA Certified Prime ratings are

More information

AESCO/MADSEN. Self-Erect Silos by AESCO/MADSEN

AESCO/MADSEN. Self-Erect Silos by AESCO/MADSEN AESCO/MADSEN Self-Erect Silos by AESCO/MADSEN AESCO/MADSEN manufactures two self-erecting silos called the WM-Series. The WM-50 has a 50-ton silo and the WM-80 has an 80-ton. The WM Series comes complete

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

Pneumatic Forklift Trucks D15G / D18G G15G / G18G. 1,500kg to 1,750kg Capacity

Pneumatic Forklift Trucks D15G / D18G G15G / G18G. 1,500kg to 1,750kg Capacity Pneumatic Forklift Trucks D15G / D18G G15G / G18G 1,500kg to 1,750kg Capacity Improve your Material Handling Performance with DOOSAN Forklifts! High Performance, Great Productivity, Energy Efficient, Superior

More information

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET STANDBY 3000 ekw 3750 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. GUARDIAN SERIES Residential Standby Generators AirCooled Gas Engine of 5 INCLUDES: True Power Electrical Technology Two Line LCD Multilingual Digital Evolution Controller (English/Spanish/ French /Portuguese)

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

SPP Pumps Inc. Atlanta

SPP Pumps Inc. Atlanta SPP Pumps Inc. Atlanta UL Listed, FM Approved Fire Pump Sets Horizontal Split Case Pumps Flows from 200-5000 US GPM Vertical Turbine Flows to 5000 US GPM In-Line Pumps Flows to 750 US GPM End Suction Flows

More information

ISUZU NPR REG CAB CAB & CHASSIS SPECS 12,000# GVWR DSL

ISUZU NPR REG CAB CAB & CHASSIS SPECS 12,000# GVWR DSL MODEL YEAR 2013 MANUFACTURER ISUZU MODEL NPR ECO-MAX GVWR 12,000# *Optional Wheelbases WHEELBASE 110.0 133.7 * 151.4 * CA DIMENSION 87.6 111.2 128.9 BOC DIMENSION 4.5 4.5 4.5 USABLE CA 83.1 106.7 124.4

More information

POWER PORTABLE GENERATORS POWER. WHEN YOU NEED IT.

POWER PORTABLE GENERATORS POWER. WHEN YOU NEED IT. POWER PORTABLE GENERATORS DO IT YOURSELF LEISURE SAFETY POWER. WHEN YOU NEED IT. How to choose a generator? RATED MAX 1. Identify the power you need 2. Identify the power quality you need Before to buy

More information