Contactors and Contactor Assemblies

Size: px
Start display at page:

Download "Contactors and Contactor Assemblies"

Transcription

1 s and ssemblies s for Switching Motors RT contactors, -pole Selection and ordering data C operation nsb0058 nsb0706g NSB060g NSB060g RT RT RT RT 2. -1L2-M0 Ratings Utilization category C-2 and C- T u : up to 60 C Operational current I e at Rating of three-phase motors at 50 Hz and C-1 T u : 0 C Operational current I e uxiliary contacts Ident. no. Rated control supply voltage U s Screw connection Cage Clamp connection for coil terminals Design DT Order No. Price DT Order No. Price 00 V 00 V up to NO NC C PG 1 1 unit PG 1 1 unit kg For screwing and snapping onto mm standard mounting rail ) 2 V, 50 Hz } RT 2-1B00 } RT 2-B V, 50 Hz } RT 2-1F00 } RT 2-F00 20 V, 50 Hz } RT 2-1P00 } RT 2-P ) 2 V, 50 Hz } RT 2-1B00 } RT 2-B V, 50 Hz } RT 2-1F00 } RT 2-F00 20 V, 50 Hz } RT 2-1P00 } RT 2-P ) 2 V, 50 Hz } RT 25-1B00 } RT 25-B V, 50 Hz } RT 25-1F00 } RT 25-F00 20 V, 50 Hz } RT 25-1P00 } RT 25-P ) 2 V, 50 Hz } RT 26-1B00 } RT 26-B V, 50 Hz } RT 26-1F00 } RT 26-F00 20 V, 50 Hz } RT 26-1P00 } RT 26-P00 with mounted auxiliary switch block (removable) Terminal designations according to EN ) 22 E V, 50 Hz } RT 2-1B V, 50 Hz } RT 2-1F0 20 V, 50 Hz } RT 2-1P ) 22 E V, 50 Hz } RT 2-1B V, 50 Hz } RT 2-1F0 20 V, 50 Hz } RT 2-1P ) 22 E V, 50 Hz } RT 25-1B V, 50 Hz } RT 25-1F0 20 V, 50 Hz } RT 25-1P ) 22 E V, 50 Hz } RT 26-1B V, 50 Hz } RT 26-1F0 20 V, 50 Hz } RT 26-1P0 with permanently mounted auxiliary switch block 2 ) Terminal designations according to EN ) 22 E V, 50/60 Hz B RT 2-1L2-M ) 22 E V, 50/60 Hz B RT 25-1L2-M ) 22 E V, 50/60 Hz B RT 26-1L2-M0 0.8 Weight approx.. For further voltages, see page /7. For accessories, see page /2. For spare parts, see page /62. For technical data, see page /92, /119. For description, see page /12. For int. circuit diagra, see page /18. For dimension drawings, see page /216. 1) Minimum conductor cross-section mm 2. 2) Further designs/voltages on request. /18 Siemens NS K 2002

2 s and ssemblies s for Switching Motors RT contactors, -pole Selection and ordering data DC operation DC solenoid system nsb0058 NSB0707g NSB060g NSB060g RT 2. -1B. 0 RT 2. -B. 0 RT 2. -1B. RT 2. -1BB-M0 Ratings Utilization category C-2 and C- T u : up to 60 C Operational current I e at Rating of three-phase motors at 50 Hz and C-1 T u : 0 C Operational current I e uxiliary contacts Ident. no. Rated control supply voltage U s Screw connection Cage Clamp connection for coil terminals Design DT Order No. Price DT Order No. Price 00 V 00 V up to NO NC DC V PG 1 1 unit PG 1 1 unit kg For screwing and snapping onto mm standard mounting rail ) 2 } RT 2-1BB0 } RT 2-BB B RT 2-1BM0 } RT 2-BM ) 2 } RT 2-1BB0 } RT 2-BB } RT 2-1BM0 } RT 2-BM ) 2 } RT 25-1BB0 } RT 25-BB } RT 25-1BM0 } RT 25-BM ) 2 } RT 26-1BB0 } RT 26-BB } RT 26-1BM0 } RT 26-BM0 S with mounted auxiliary switch block (removable) Terminal designations according to EN ) 22 E } RT 2-1BB B RT 2-1BM ) 22 E } RT 2-1BB } RT 2-1BM ) 22 E } RT 25-1BB } RT 25-1BM ) 22 E } RT 26-1BB } RT 26-1BM with permanently mounted auxiliary switch block 2 ) Terminal designations according to EN ) 22 E B RT 2-1BB-M ) 22 E B RT 25-1BB-M ) 22 E B RT 26-1BB-M Weight approx. For further voltages, see page /7. For accessories, see page /2. For technical data, see page /96, /119. For description, see page /12. For int. circuit diagra, see page /18. For dimension drawings, see page /216. 1) Minimum conductor cross-section mm 2. 2) Further designs/voltages on request. /22 Siemens NS K 2002

3 s and ssemblies RT1 s ccessories for contactors Selection and ordering data nsb0078 nsb071g NSB060g nsb06g nsb0080 nsb0081g RH F... RH F... RH C... RH C... RH L.. RH M.. For contactors Rated operational current I e /C-15/C-1 at 20 V uxiliary contacts Screw connection Cage Clamp connection Weight approx. Ident. Design DT Order No. Price DT Order No. Price no. NO NC NO NC PG 1 1 unit PG 1 1 unit kg uxiliary switch blocks for snapping onto the front acc. to EN s to S12 1 ) -pole auxiliary switch blocks RT 2, 6 0 } RH F0 } RH F unit RT1. to 1 1 } RH F1 } RH F1 RT1. 7, } RH F22 } RH F22 RT11 0 } RH F0 } RH F0 22 U 2 2 } RH FC22 RH FC22 Single-pole auxiliary switch blocks acc. to EN and EN (1 pack = ) RT1. 2 to 6 1 } RH C } RH C pack RT1. 7, 1 } RH C01 } RH C01 RT11 1 RH CD 1 RH CD01 RT 2, RT1. to RT1. 7, RT11 NS2SYM01 NS2SYM02 NS2SYM05 2-pole auxiliary switch blocks with cable entry from one side Cable entry from above NS2SYM } RH L unit 2 } RH L20 2 } RH L02 Cable entry from below } RH M unit 2 } RH M20 2 } RH M02 Pack. For int. circuit diagra, see page /19. For position of terminals, see page /15. 1) Exception: RT16. /2 Only supplied in packings Siemens NS K 2002

4 s and ssemblies s for Switching Motors RT 2. contactors Technical data RT 2. General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation Upright mounting position: C operation Standard design DC operation Special design required; also applies to RT K. 0 coupling relays Positions 1 to 16 of the Order No. must be changed to -. In the case of RT 2. -K. -0L0 contactors with extended coil voltage tolerance, positions 1 to 16 of the Order No. are changed to -1L0. dditional charge Mechanical Basic Oper. million endurance Basic unit with snap-on auxiliary switch block cycles million Solid-state compatible aux. switch block 5 million Electrical endurance See page /86 Rated insulation voltage U i (pollution degree ) V 690 Rated impulse withstand voltage U imp kv 6 Safe isolation between coil and main contacts (acc. to DIN VDE 06 Part 1 and 1 [draft 2/89]) Positively driven operation There is positively driven operation if the NC and NO contacts cannot be closed at the same time Positively driven operation for contactors with solid-state compatible auxiliary switch block according to Swiss regulations (SUV) on request. Permissible ambient temperature V 00 RT 2., RT1 2. (removable aux. switch block) RT 2., RT1 2. (permanent aux. switch block) in operation when stored C C Yes, between main contacts and auxiliary NC contacts and within the auxiliary switch blocks acc. to ZH 1/57, IEC , nnex H (draft 17B/996/DC) Yes, between main contacts and auxiliary NC contacts and within the auxiliary switch blocks acc. to ZH 1/57, IEC , nnex H (draft 17B/996/DC), Swiss regulations (SUV) Degree of protection acc. to IEC and DIN IP 20, coil system IP 20 Shock resistance Rectangular pulse C operation g/ 8.2/5 and.9/ DC operation g/ /5 and / Sine pulse C operation g/ 12.5/5 and 7.8/ DC operation g/ 15/5 and / Conductor cross-sections See page /95 Short-circuit protection of contactors without overload RT 2, RT 2, RT 25 RT 26 For short-circuit protection of contactors with overload relays, see Part. For short-circuit protection of weld-free contactors, see Part 5. (overload and short-circuit protection only with RV circuitbreaker). For short-circuit protection of fuseless load feeders, see Part 5. Main circuit Fuse links, utilization category gl/gg NH N, DIZED 5SB, NEOZED 5SE With fuse links acc. to IEC /EN of coord. "1" 1 ) 6 0 of coord. "2" 1 ) 25 Weld-free 2 ) 16 or miniature circuit-breaker with C-characteristic 25 2 (short-circuit current k, type of coordination "1") 1 ) uxiliary circuit Fuse links, utilization category gl/gg DIZED 5SB, NEOZED 5SE (weld-free protection at I k 1 k) or miniature circuit-breaker with C-characteristic (short-circuit current I k < 00 ) 1) ccording to excerpt from IEC (VDE 0660 Part 2): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 2) Test conditions acc. to IEC For RT11 weld-free contactors, see Part 5 (overload and short-circuit protection only with RV circuit-breaker). /92 Siemens NS K 2002

5 s and ssemblies s for Switching Motors RT 2. contactors Technical data Control circuit RT 2. Coil voltage tolerance C/DC U s Power consumption of the coils (with coil in cold state and 1.0 U s ) Standard design For US and Canada C operation Hz 50 50/ closing p.f. closed p.f. DC operation closing = closed W 5. Permissible residual current of the electronics (with 0 signal) C operation DC operation Operating times at U s 1) Break-time = opening time + arcing time C operation closing time opening time DC operation closing time opening time rcing time Operating times at 1.0 U s 1 ) C operation DC operation closing time opening time closing time opening time V V m m V < 6 m x U s 2 V < 16 m x U s /6 0.72/ / / Main circuit Load ratings with C C-1 utilization category, switching resistive load Rated operational currents I e Ratings of three-phase loads 2 ) p.f. = 0.95 (at 60 C) at 0 C up to at 60 C up to at 20 V 00 V Minimum conductor cross-section with I e load at 0 C 60 C C-2 and C- utilization categories Rated operational currents I e Ratings of slipring or squirrel-cage motors at 50 Hz and 60 Hz up to 00 V at 1 V 20 V 00 V 660/ RT 2, RT mm 2 mm RT 2, RT RT 25 Thermal loading capacity s current ) Power loss per conducting path at I e /C- W RT ) The opening times of the NO contacts and the closing times of the NC contacts increase if the contactor coils are protected against voltage peaks (varistor +2 to 5, diode assemblies: 2 to 6 times). 2) Industrial furnaces and electric heaters with resistance heating, for example (higher current input allowed for during heating up). ) cc. to VDE 0660 Part 2. For rated values for various starting conditions, see Part. Siemens NS K 2002 /9

6 s and ssemblies s for Switching Motors RT 2. contactors Technical data RT 2 RT 2 RT 25 RT 26 Main circuit Load ratings with C C- utilization category (at I a = 6 I e ) Rated operational current I e up to 00 V Ratings of squirrel-cage motors at 50 Hz and 60 Hz at 00 V For a contact endurance of approx operating cycles: Rated operational currents I e up to 00 V Ratings of squirrel-cage motors at 50 Hz and 60 Hz at 1 V 20 V 00 V C-5a utilization category, switching gas discharge lamps per main conducting path at 20 V 1 ) Rating per lamp Rated operational current per lamp () uncorrected lead-lag Switching gas discharge lamps with correction, electronic ballast per main conducting path at 20 V Rating per lamp Capacitor (µf) Rated operational current per lamp () Parallel correction With electronic ballast, single lamp With electronic ballast, twin lamp C-5b utilization category, switching incandescent lamps per main conducting path at 20/220 V C-6a utilization category, switching three-phase transformers with inrush n Rated operational current I e up to 00 V ,2 Ratings of three-phase transformers with an inrush of n = 0 or 20. The ratings must be re-calculated for other inrush factors x: 0 P x = P n x at 20 V 00 V C-6b utilization category, switching low-inductance (low-loss, metallized-dielectric) three-phase capacitors Rated operational currents I e up to 00 V Ratings of single capacitors or of capacitor banks (minimum inductance between parallel capacitors 6 µh) at 50 Hz, 60 Hz and at 20 V 00 V kv kv kv kv kvar kvar kvar kvar ) I e /C-1 = (60 C) and with the corresponding minimum conductor cross-section mm 2. /9 Siemens NS K 2002

7 s and ssemblies s for Switching Motors RT 2. contactors Technical data Main circuit Load ratings with DC DC-1 utilization category, switching resistive load (L/R 1 ) Rated operational current I e (at 60 C) DC- and DC-5 utilization categories, shunt and series motors (L/R 15 ) Rated operational current I e (at 60 C) RT 2, RT 2, RT 25 Number of conducting paths connected in series 1 2 up to 2 V 60 V 1 V 220 V 0 V 600 V Number of conducting paths connected in series 1 2 up to 2 V 60 V 1 V 220 V 0 V 600 V RT 26 Operating frequency Operating frequency z in operating cycles per hour C DC C DC s without overload relays No-load operating frequency Dependence of the operating frequency z on the operational current I and the operational voltage U : I e z = z V I U 1.5 for C-1 for C-2 for C- for C- s with overload relays (mean value) Conductor cross-sections Screw connections (1 or 2 conductor connections possible) Main conductor: Solid mm 2 2 ( ); 2 ( ) Finely stranded with end sleeve mm 2 2 ( ); 2 ( ) acc. to IEC 60 97; max. 1 WG conductor connections, solid solid or stranded stranded WG WG WG 2 ( ) 2 (1... ) 1 8 Terminal screws M (Pozidriv size 2) Tightening torque Nm ( lb.in) uxiliary conductor: Solid mm 2 2 ( ); 2 ( ) acc. to IEC 60 97; max. 2 ( ) Finely stranded with end sleeve mm 2 2 ( ); 2 ( ) WG conductor connections, solid or stranded WG 2 ( ); 2 ( ); 1 12 Terminal screws M Tightening torque Nm (7.... lb.in) Cage Clamp connections (1 or 2 conductor connections possible) C/DC uxiliary conductor: Solid mm 2 2 ( ) Finely stranded with end sleeve mm 2 2 ( ) Finely stranded without end sleeve mm 2 2 ( ) WG conductor connections, solid or stranded WG 2 (2... 1) For tool for opening the Cage Clamp connection, see accessories on page /52. n "insulation stop" must be used for conductor cross-sections 1 mm 2, see accessories on page /52. Max. outer diameter of conductor insulation:.6 mm. For information about Cage Clamp connections, see page. C/DC Siemens NS K 2002 /95

8 s and ssemblies RT contactors, -pole s and ssemblies Dimension drawings RT 1 contactors 0, screw connection with surge suppressor, auxiliary switch block and mounted overload relay Lateral clearance from earthed parts = 6 mm 2) uxiliary switch block (also RH NF.. solid-state compatible design) ) Surge suppressor (also RT G00 additional load module) ) Drilling pattern RT 1 contactors 0, Cage Clamp connection with auxiliary switch block RT 2 contactors, RT 2 coupling relays, screw connection with surge suppressor, auxiliary switch blocks and mounted overload relay For size : a = mm at < 20 V a = 7 mm at > 20 V b = DC mm deeper than C 1) uxiliary switch block, laterally mountable 2) uxiliary switch block, mountable on the front, 1, 2 and -pole (also RH FE22 solid-state compatible design) ) Surge suppressor ) Drilling pattern /216 Siemens NS K 2002

9 s and ssemblies RT contactors, -pole s and ssemblies Dimension drawings RT 2 contactors, RT 2 coupling relays, Cage Clamp connection with surge suppressor, auxiliary switch blocks and mounted overload relay For size : a = 0 mm with varistor < 20 V, diode assembly a =.5 mm with varistor > 20 V a = 17 mm with RC element b = DC 15 mm deeper than C 1) uxiliary switch block, laterally mountable 2) uxiliary switch block, mountable on the front (1, 2 and -pole) ) Surge suppressor ) Drilling pattern RT contactors S2, screw connection with surge suppressor, auxiliary switch blocks and mounted overload relay For size S2: a = 0 mm with varistor < 20 V, diode assembly a =.5 mm with varistor > 20 V a = 17 mm with RC element b = DC 15 mm deeper than C 1) uxiliary switch block, laterally mountable 2) uxiliary switch block, mountable on the front (1, 2 and -pole) ) Surge suppressor ) Drilling pattern Siemens NS K 2002 /217

Switching Devices Contactors and Contactor Assemblies Special Applications

Switching Devices Contactors and Contactor Assemblies Special Applications Switching Devices Contactors and Contactor Assemblies Special Applications Price groups PG 1B, 1H /2 Introduction Contactors for special applications / SIRIUS 3RT1 contactors for resistive loads (AC-1),

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches Siemens AG 2014 Switching Devices /2 Introduction /5 5TE control switches / 5TE4 pushbuttons /11 5TE5 light indicators /13 5TE On/Off switches /20 5TE DC isolators /22 5ST busbars for modular installation

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

MULTIFUNCTION TIME RELAY CRM-93H

MULTIFUNCTION TIME RELAY CRM-93H 4 MULTIFUNCTION TIME RELAY CRM-93H - 10 functions Features: Universal supply voltage AC/DC 12-240V 10 functions: - 5 time functions controlled by supply voltage - 4 time functions controlled by control

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

3RV Motor Starter Protectors up to 100 A

3RV Motor Starter Protectors up to 100 A General data Overview S0 motor 3RV1 motor are compact, current limiting motor which are optimized for load feeders. The motor are used for switching and protecting three-phase induction motors of up to

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Plug-in relays Mini ISO relays

Plug-in relays Mini ISO relays Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

Residual Current Protective Devices

Residual Current Protective Devices Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8

More information

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet 101780_en_02. 1 Description

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet 101780_en_02. 1 Description PLC INERFCE With PD Relay, niversal Version INERFCE Data Sheet 780_en_02 PHOENIX CONC - 03/08 Description PLC-RS /2 relay modules, which can be used universally, comprise 6.2 mm basic terminal blocks and

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

General Purpose Relays Accessories. Accessories Miniature Relay PT

General Purpose Relays Accessories. Accessories Miniature Relay PT Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Controls Solid-State Switching Devices

Controls Solid-State Switching Devices Controls Solid-State Switching Devices Introduction Overview 3RF21 3RF20 3RF23 3RF29 SIRIUS SC solid-state switching devices Solid-state relays 22.5 mm solid-state relays, 5 mm solid-state relays Solid-state

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

SICOP. Low Voltage Control Components. www.siemens.co.in

SICOP. Low Voltage Control Components. www.siemens.co.in s SICOP Low Voltage Control Components Datasheet 205 www.siemens.co.in s Planning Efficiency Cx pplications Save Time. Save Money. vailable for: 3TF contactors 3U/3UC thermal overload relays 3VU MPCB Index

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

How can a charging station for electric vehicles be set up simply and safely?

How can a charging station for electric vehicles be set up simply and safely? SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power,

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays

Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays Siemens AG 2013 Switching Devices Contactors and Contactor Assemblies Contactor Relays and Relays Price groups 41A, 41B, 41H, 4N1 /2 Introduction Contactor relays /4 SIRIUS 3RH2 contactor relays, 4- and

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information