TECHNICAL SPECIFICATIONS
|
|
- Ashlyn Tucker
- 7 years ago
- Views:
Transcription
1 TECHNICAL SPECIFICATIONS Model MGC2S (A and K) Series M120 Product Line High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 80+ AFUE Input 45, ,000 Btuh
2 2
3 12 YEAR ALL PARTS WARRANTY This product offers a 1-Year Dependability Promise to replace the unit if the heat exchanger fails within the first year of operation, to the original owner. Product registration required for 12-year All Parts Warranty and Dependability Promise within a limited period of time after the installation. See current warranty document for details. This can be viewed at or ask your sales representative. Also when registered, this product is upgraded to a limited lifetime heat exchanger warranty. The high efficiency gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing appliance appearance. Design certified by CSA for Canada and the United States. Features and Benefits - 100% fired and tested: All units and each component are tested on the manufacturing line. Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free. - Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install. - Tubular primary heat exchanger Heavy gauge aluminized steel heat exchanger assures a long life second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds) second post purge: Increases life of heat exchanger. - Hot surface igniter: Innovative application of an appliance type igniter with a 20 year history of reliability. Utilizes proven SmartStart technology. - Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement. - High static blowers: All models equipped with high static blowers second cooling cycle blower-off delay (TDR) : increases cooling performance when matched with a NORDYNE coil. - Flexible category I venting system: May be vented with dedicated venting system or common vented with other category one appliances. - High efficiency blower kits: Maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized. - Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra easy motor speed selection. - LP convertible: Simple burner orifice and regulator spring change for ease of convertibility. - Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes. - Integrated control board: Incorporates connections for electronic air cleaner and humidifier. - Two piece door design: Enhances furnace appearance and uses captured screws to prevent loosing door screws. - Blower Compartment: Insulated for ultra quiet operation. 3
4 GAS FURNACE COMPONENTS Main Air Limit Switch Inducer Assembly Transformer Igniter Blower Door Switch Control Board Gas Valve Pressure Switch Flame Sensor Gas Manifold Burner Assembly Roll-Out Switch Blower Assembly Upflow/Horizontal Gas Furnace Blower Assembly (behind blower panel) Blower Door Switch (behind blower panel) Combustion Tube Control Board Transformer Pressure Switch Inducer Assembly Main Air Limit Switch Igniter Gas Valve Gas Manifold Burner Assembly Roll-Out Switch Flame Sensor Downflow Gas Furnace 4
5 DIMENSIONS *SA Model # s A B C D A A 14 1/4 10 3/4 12 5/8 12 7/ B B 17 1/2 11 3/4 15 7/8 16 1/ C C C D / /4 19 3/8 22 7/8 19 7/8 23 1/8 23 TOP VIEW C FLANGES B /2 BOTTOM VIEW D Front Brace Bottom Panel Accepts 4 Type B Vent Pipe T-stat (Ø 7/8) 25 3/8 Electric (Ø 7/8) 4 Knockouts (both sides) Gas (1 5/8 X 3 1/2) A Electric (Ø 7/8) 29 1/2 22 1/2 22 1/ /4 Gas (1 5/8 X 3 1/2 X 45 ) 22 3/4 34 1/2 1 1/4 23 LEFT SIDE 1 FRONT VIEW 28 RIGHT SIDE MGC2SA 80+ High Efficiency Upflow/Horizontal Series TOP VIEW BOTTOM VIEW *SK Model # s A B C D A 14 1/4 10 3/4 12 5/8 12 7/ B B 17 1/2 11 3/4 15 7/8 16 1/ C /8 19 5/ D 24 1/2 15 1/4 22 7/8 23 1/8 23 C FLANGES /8 D Front Brace B Accepts 4 Type B Vent Pipe Electric (Ø 7/8) A T-stat (Ø 7/8) Electric (Ø 7/8) 22 1/ /2 Gas (1 5/8 X 3 1/2) 22 1/2 29 1/2 22 1/2 Gas (1 5/8 X 3 1/2 X 45 ) 25 3/ LEFT SIDE FRONT VIEW RIGHT SIDE MGC2SK 80+ High Efficiency Downflow Series 5
6 BLOWER PERFORMANCE MGC2SA Model Number Heating Input (Btuh) SA045( )-23A Bottom Return 45,000 SA045( )-23A 45,000 SA054( )-23A Bottom Return 54,000 SA054( )-23A 54,000 SA072( )-24B Bottom Return 72,000 SA072( )-24B 72,000 SA090( )-24B Bottom Return 90,000 SA090( )-24B 90,000 SA072( )-35C Bottom Return 72,000 SA072( )-35C 72,000 Motor Speed External Static Pressure (Inches Water Column) CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise High* Med-High Med-Low** Low High* Med-High Med-Low** Low High* Med-High Med-Low** Low High* Med-High Med-Low** Low High* Med-High Med-Low** Low High* Med-High Med-Low** Low High* Med-High** Med-Low Low High* Med-High** Med-Low Low High* Med-High Med-Low** Low High* Med-High Med-Low** Low
7 BLOWER PERFORMANCE MGC2SA Continued Model Number SA072( )-35C Side + Bottom or 2 Sides SA090( )-35C Bottom Return SA090( )-35C SA090( )-35C Side + Bottom or 2 Sides Heating Input (Btuh) 72,000 90,000 90,000 90,000 SA108( )-35C Bottom Return 108,000 SA108( )-35C SA108( )-35C Side + Bottom or 2 Sides SA126( )-45D Bottom only or 2 openings SA126( )-45D 108, , , ,000 Motor Speed External Static Pressure (Inches Water Column) CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise High* Med-High Med-Low** Low High* Med-High** Med-Low Low High* Med-High** Med-Low Low High* Med-High** Med-Low Low High* Med-High** Med-Low Low High* Med-High** Med-Low Low High* Med-High** Med-Low Low High* Med-High** Med-Low Low High* Med-High** Med-Low Low NOTES: ( ) Can be C or N 1. Two openings are recommended for airflows above 1600 CFM if filter(s) is(are) adjacent to furnace. * Factory Set Cooling Speed 2. Temperature rises in the table are approximate. Actual temperature rises may vary. ** Factory Set Heating Speed 3. Temperature rises shaded in gray are for reference only. These conditions are not recommended. 7
8 BLOWER PERFORMANCE MGC2SK Model Number Heating Input (Btuh) SK054( )-23A 54,000 SK072( )-24B 72,000 SK090( )-24B 90,000 SK108( )-35C 108,000 SK126( )-45D 126,000 Motor Speed External Static Pressure (Inches Water Column) CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise High* Med-High Med-Low** Low High* Med-High Med-Low** Low High* Med-High Med-Low** Low High* Med-High Med-Low** Low High* Med-High Med-Low** Low ( ) Can be C or N NOTES: * Factory Set Cooling Speed 1. Temperature rises in the table are approximate. Actual temperature rises may vary. ** Factory Set Heating Speed 2. Temperature rises shaded in gray are for reference only. These conditions are not recommended. 8
9 IDENTIFICATION CODE Maytag Gas Compact Design Series S = Single Stage T = Two Stage A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal K = 80% Downflow L = 92.1% / 95.1% Downflow MGC 2 S A 090 C 23 B Input Heating Capacity 045 = 45, = 90, = 54, = 108, = 72, = 126,000 C = Standard N = 80% AFUE Low NOx Cabinet Width A = B = C = D = Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons SPECIFICATIONS MGC2SA MODEL NUMBERS A A B B C C C D Input - Btuh (a) 45,000 54,000 72,000 90,000 72,000 90, , ,000 Heating Capacity - Btuh 36,000 43,200 57,600 72,000 57,600 72,000 86, ,800 AFUE Blower D x W 10 x 6 10 x 6 11x 8 11 x 8 10 x x x x 10 Motor H.P. - Speed - Type 1/3-4 - PSC 1/3-4 - PSC 1/2-4 - PSC 1/2-4 - PSC 1/2-4 - PSC 1/2-4 - PSC PSC PSC Motor FLA Rated Ext. SP - In. W.C Temperature Rise Range - ºF Shipping Weights 100lbs 100lbs 110lbs 115lbs 115lbs 120lbs 125lbs 145lbs MGC2SK MODEL NUMBERS A B B C D Input - Btuh (a) 54,000 72,000 90, , ,000 Heating Capacity - Btuh 43,200 57,600 72,000 86, ,800 AFUE Blower D x W 10 x 6 11 x 8 11 x 8 11 x x 10 Motor H.P. - Speed - Type 1/3-4 - PSC 1/2-4 - PSC 1/2-4 - PSC 3/4-4 - PSC PSC Motor FLA Rated Ext. SP - In. W.C Temperature Rise Range - ºF Shipping Weights 100lbs 110lbs 115lbs 125lbs 145lbs 9
10 ACCESSORIES MGC2S (A, K) KITS Description SKU "A" Cabinet fixed speed, high efficiency, FSHE "B" Cabinet fixed speed, high efficiency, FSHE "C" Cabinet fixed speed, high efficiency, FSHE "D" Cabinet fixed speed, high efficiency, FSHE "A" Cabinet variable speed, high efficiency, VSHE "B" Cabinet variable speed, high efficiency, VSHE "C" Cabinet variable speed, high efficiency, VSHE "D" Cabinet variable speed, high efficiency, VSHE "A" Cabinet downflow sub base kit "B", "C", "D" Cabinet downflow sub base kit U.S. LP Conversion kit (0 to 10,000 ft.) Canada LP Conversion kit (0 to 4,500 ft.) Bottom return filter 20 per box, "A" cabinet Bottom return filter 20 per box, "B" cabinet Bottom return filter 20 per box, "C" cabinet Bottom return filter 20 per box, "D" cabinet Side return filter kit
11 11
12 Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Manufactured under license by NORDYNE, O Fallon, MO. Registered Trademark/ TM Trademark of Maytag Corporation or its related companies All rights reserved. 745C-0211 (Replaces 745C-0608) Printed in U.S.A. (02/11)
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationTECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
More informationF9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
More informationXV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE
UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB
More informationG9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
More informationTECHNICAL MANUAL GDS8 & GHS8
TECHNICAL MANUAL AL GDS8 & GHS8 33-3/8" 80% Gas Furnace Units Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be followed as
More informationGas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
More informationG26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
More informationOIL FURNACES. Clean, Comfortable Oil Heat From
OIL FURNACES Clean, Comfortable Oil Heat From Features 3 1 2 5 10 9 7 6 8 4 1 Foil-faced high density fi berglass insulation gives durable, insulating heat and sound protection. 2 Heavy-duty 14 gauge steel
More informationOIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.
FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic
More informationXV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.
Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing Gas-Fired Furnace XV 95 TUH2B060A9V3VB TUH2B080A9V3VB TUH2B080A9V4VB TUH2C100A9V4VB TUH2C100A9V5VB TUH2D120A9V5VB Direct Vent
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use
More informationINDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationINDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationINDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES
More informationAIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency
FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant
More informationINDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
More informationARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
More informationHigh efficiency, cast-iron gas boiler
SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home
More informationInstallation Instructions
VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling
More informationCommercial Gas Water Heaters
POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600
More information48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT
48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED
More informationhttp://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationE2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationInstallation Instructions
H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.
More informationSeries GM. Peerless Boilers. Residential/Commercial Gas Boilers
Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler
More informationINSTALLATION MANUAL RESIDENTIAL GAS FURNACE. MODELS: TG9S*MP, GG9S*MP (95.5% AFUE Single Stage Multi-position) LIST OF SECTIONS LIST OF FIGURES
INSTALLATION MANUAL RESIDENTIAL GAS FURNACE MODELS: TG9S*MP, GG9S*MP (95.5% AFUE Single Stage Multi-position) SAFETY........................................... 2 DUCTWORK........................................
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT ALPKT7- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... INSTALLATION INSTRUCTIONS...
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationGCS16-024-030-036-048-060
Packaged Unit & Gas Heat 2-5 Ton Capacity 50,000-120,000 Btuh Input Heating Capacity GCS16-024-030-036-048-060 FEATURES Designed for outdoor rooftop or ground level installations Down-flow or horizontal
More informationSL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationGCS16 GCS20 WARNING CAUTION
Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat
More informationG6 Series. 90+ High Efficiency Upflow/Downflow Models. Service Manual
G6 Series 90+ High Efficiency Upflow/Downflow Models Service Manual D. C. B. A. Typical meters used to service furnaces. A. Differential Pressure Gauge B. Volt-Ohm Meter C. Manometer D. Slant Gauge TABLE
More informationSplit System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
More informationEFFECTIVE OCTOBER 2005. Atwood Furnaces. and Digital Thermostats
EFFECTIVE OCTOBER 2005 Atwood Furnaces and Digital Thermostats Unique 2-Stage System Set the temperature, turn the thermostat on automatic and let the furnace take over! During cold start-ups, the furnace
More informationPRODUCT DESIGN. 5. Furnace awaits call from thermostat.
Goodman / Amana Distinctions Brand Single-Stage 80% or 90% Furnaces White-Rodgers 50A55 Integrated Ignition Control 1. 115 VAC power applied to furnace. 2. Integrated ignition control module performs internal
More informationhttp://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for
More informationCommercial Gas Water Heaters
CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable
More informationThe formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08
Air Volume Requirement Air conditioning systems are engineered with a specific amount of indoor air passing across the surface of the evaporator coil. The amount of air is measured in cubic feet per minute.
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationCommercial Gas Water Heaters
UP TO 96% THERMAL EFFICIENCY, DIRECT-VENT FEATURES TM BTH-120 through BTH-500 The A. O. Smith Cyclone Xi family of products represents the industry s most technologically advanced commercial water heaters.
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationRESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
More informationVertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
More informationAluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible
More informationPropane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
More informationELITE SERIES Up Flow / Horizontal Precision Speed Blower
G S F U R N C E S G50UHi ELITE SERIES Up Flow / Horizontal Precision Speed Blower E N G I N E E R I N G D T Bulletin No. 210380 ugust 2005 Supersedes May 2004 FUE 80% Input 66,000 to 132,000 Btuh Nominal
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More information80UHG. Service Literature
Service Literature Corp. 9728 L12 Revised 01 2002 80UHG 80UHG series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with tubular heat exchangers formed
More informationOriginators of the Flexible Water Tube design
BRYAN FLEXIBLE WATER TUBE AB SERIES STEAM AND WATER BOILER 900,000 TO 3,000,000 BTUH FORCED DRAFT GAS, OIL OR DUAL FUEL FIRED Water Boiler AB120-W-FDGO Steam Boiler AB250-S-150-FDG Originators of the Flexible
More informationG234X-55 Conventional Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural
More informationGreensource iseries HY Model Unitary Air Handler/Fan Coil
Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC
More informationAir Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
More informationFactory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
More informationBelow are detailed instructions for using the EMS load calculator.
Introduction The EMS load calculator is designed to make load calculating as painless as possible. For sizing the equipment, only the first three tabs (Steps 1, 2 & 3) need to be completed. This process
More informationSplit System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
More informationRESIDENTIAL PRODUCT LINE CARD 15.5
RESIDENTIAL PRODUCT LINE CARD 15.5 Amana is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX, USA. All rights reserved.
More informationCommunicating Controls Service Manual
Communicating Controls Service Manual History 1977 1991 Theory of Operation Common Components Telephone Access Module Service/Troubleshooting Table of Contents Warnings and Cautions... 2 Theory of Operation
More informationHeating Ventilation and Air Conditioning Diagnostics for Single Family Homes
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning
More informationLocal Dealer: www.cebrands.com
Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication
More informationCommercial Gas Water Heater
Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service
More informationMechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
More informationInstaller s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
More informationCASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS
CASED & UNCASED UPFLOW & DOWNFLOW EVAPORATOR COILS Description / Application Compact, versatile, right or left horizontal position May be used in closet, utility room, or basement Standard Finish Fully
More informationFossil fuel heating equipment
Fossil fuel heating equipment principles and troubleshooting techniques Application Note This application note was written to provide you with an understanding of the basic principles of fossil fuel heating
More informationWORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designer/Signature:
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
More informationTB-A028-06 - A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION
1 2 3 4 5 Inadequate or no earth ground sensed by the Intelli-Vent control. Power supply to Intelli-Vent control has reversed polarity. Pressure switch circuit remaining closed for more than 5 seconds
More informationM1 Series. M1G and M1M Furnaces. Service Manual
M1 Series M1G and M1M Furnaces Service Manual D. C. B. A. Typical meters used to service M1 furnaces. A. Differential Pressure Gauge B. Volt-Ohm Meter C. Manometer D. Inclined Manometer TABLE OF CONTENTS
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationHow To Install A Perfect 16 Id Series Filter System
IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System Perfect 16 Installation Manual Product Data High-Performance Medical-Grade Residential/Commercial Air Filtration System Application The
More informationHEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.
HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is
More informationTWE+TTA TWE+TWA 6.25-20 T.R.
TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.
More informationGALAXY. High performance gas boilers HOT WATER AND STEAM NATURAL AND L.P. PROPANE GASES
GALAXY High performance gas boilers HOT AND STEAM NATURAL AND L.P. PROPANE GASES GALAXY Cast-iron boilers Slant/Fin s Galaxy is one of America s most trusted gas boilers. Installed in tens of thousands
More informationDESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System
TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED
More informationCircuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)
UNIT OBJECTIVES Describe the concept of year-round air conditioning List three typical year-round air conditioning system types List the five ways to condition the air Determine airflow for a cooling system
More informationRoof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
More informationEvaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
More informationTHC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type
More informationCondensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED
High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from
More informationCooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
More informationDiagnostics for Mobile Homes: HVAC
Diagnostics for Mobile Homes: HVAC Adam Harris NYSWDA Wade Thompson - IWTC Objectives Identify different types of HVAC used in mobile homes Provide an overview of duct systems Demonstrate various tests
More informationUDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
More informationCABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.
Lanair Clean Burn CABINET Lanair's lightweight heat exchanger provides very little travel for the heat to be picked-up and ultimately be transferred to your shop. It uses a 2-pass design made up of 12
More informationIMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.
QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your
More informationLG AIR CONDITIONING SYSTEMS Art cool Mini-Split Flex Multi-Split Floor Standing Window Room Air PTAC
HVAC EQUIPMENT LG AIR CONDITIONING SYSTEMS Art cool Mini-Split Flex Multi-Split Floor Standing Window Room Air PTAC Page # A A-Coils...19, 27-28, 31, 34-35 ADP (ADVANCED DISTRIBUTOR PRODUCTS)...31, 69
More informationInstallation Instructions
Installation Instructions For Use with PXPV230, PXPV265, PXPD230, and PXPD265 models Attention! - Please read these instructions completely before attempting installation. Always unplug the power supply
More informationInstallation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
More informationLow Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
More informationPackaged Gas/Electric Rooftop Units
Packaged Gas/Electric Rooftop Units Voyager 12½ 25 Tons 60 Hz December 2003 Introduction Voyager TM... a proven performer built to provide ultimate indoor comfort. Voyager continues to provide the highest
More information