1 Presentation Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN Variable composition Square rod lever, steel, U mm L = mm () Round rod lever, glass fibre, Ø mm L = mm () ZCK D ZCK D ZCK D Round rod lever, thermoplastic, Ø mm L = mm () Elastomer roller lever, Ø mm () Variable length elastomer roller lever, Ø mm () ZCK D ZCK D ZCK D Variable length thermoplastic roller lever, () Thermoplastic roller lever () ZCK D Steel roller lever () ZCK D Steel ball bearing mounted roller lever () ZCK D Spring rod Cat s whisker Spring-rod lever with thermoplastic end () ZCK D ZCK D ZCK D Spring-rod lever, metal () ZCK D Metal end plunger ZCK D End metal plunger with protective boot ZCK D Steel roller plunger ZCK D Steel roller plunger with protective boot ZCK D Body with -pole contact, cable entry for Pg. step () Body with -pole contact, cable entry for Pg. step () ZCK S, S, S, S, S ZCK S, S ZCK SD, SD, SD, SD () For further details see page /. For a cable entry tapped ISO M x., add H to the reference. Example: ZCK S becomes ZCK SH. () Adjustable throughout in steps, or in steps by reversing the notched washer. () Adjustable throughout in steps, or in steps by reversing the lever mounting. Rugghölzli CH - Busslingen Tel. + () Fax + ()

2 Presentation (continued) Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN Variable composition Square rod lever, steel, U mm L = mm () Round rod lever, glass fibre, Ø mm L = mm () Round rod lever, Ø mm L = mm () ZCK Y ZCK Y ZCK Y Spring-rod lever with thermoplastic end () Spring-rod lever, metal () ZCK Y ZCK Y Variable length thermoplastic roller lever, () Variable length steel roller lever () Variable lengthelastomer roller lever, Ø mm () Elastomer roller lever, Ø mm () ZCK Y ZCK Y ZCK Y ZCK Y Thermoplastic roller lever () Steel roller lever () Steel ball bearing mounted roller lever () ZCK Y ZCK Y ZCK Y For actuation from left AND right or from left OR right ZCK D Body with double-pole CO, staggered, contact cable entry for Pg. step, from left AND from right () ZCK S () For further details see page /. For a cable entry tapped ISO M x., add H to the reference. Example: ZCK S becomes ZCK SH. : NC contact with positive opening operation or head assuring positive opening operation. () Adjustable throughout in steps, or in steps by reversing the notched washer. () Adjustable throughout in steps, or in steps by reversing the lever mounting. Rugghölzli CH - Busslingen Tel. + () Fax + ()

3 References Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN Adaptable sub-assemblies Bodies with -pole contact Type With contact block step NC + NO (XES P) Scheme Positive Cable entry Reference Weight operation () kg Pg. ZCK S. ISO M x. ZCK SH. ZCK Sp ZCK S CO (XES P) NC + NO (XEN P) NO + NC make before break, (XEN P) NC + NC (XEN P) NO + NO (XEN P) NC + NC (XES P) Bodies with double-pole contact and spring return rotary head Without operating lever Type Scheme step from left and from right With contact block CO staggered Bodies with -pole contact and cable entry Type With contact block NC + NO + NO (XES P) NC + NC + NO (XES P) NC + NC + NO (XEN P) NC + NO + NO (XEN P) Scheme Pg. ZCK S. ISO M x. ZCK SH. Pg. ZCK S. ISO M x. ZCK SH. Pg. ZCK S. ISO M x. ZCK SH. Pg. ZCK S. ISO M x. ZCK SH. Pg. ZCK S. Positive operation () ISO M x. ZCK SH. Pg. ZCK S. ISO M x. ZCK SH. Cable entry Reference Weight kg Pg. ZCK S. Positive operation () () : NC contact with positive opening operation or head assuring positive opening operation. ISO M x. ZCK SH. Cable entry Reference Weight kg Pg. ZCK SD. ISO M x. ZCK SDH. Pg. ZCK SD. ISO M x. ZCK SDH. Pg. ZCK SD. ISO M x. ZCK SDH. Pg. ZCK SD. ISO M x. ZCK SDH. Rugghölzli CH - Busslingen Tel. + () Fax + ()

4 References (continued) Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN Adaptable sub-assemblies Contact blocks Type of contact Scheme For body Positive operation () -pole contact NC + NO Reference Weight kg ZCK S XES P. XES Pp NC + NO ZCK S XEN P. CO simultaneous ZCK S XES P. XEN Pp NO + NC make before break, ZCK S XEN P. XES P NC + NC NO + NO ZCK S XEN P. ZCK S XEN P. NC + NC -pole contact NC + NO + NO ZCK S XES P. ZCK SD XES P. XEp Ppp NC + NC + NO ZCK SD XES P. NC + NC + NO ZCK SD XEN P. NC + NO + NO ZCK SD XEN P. () : NC contact with positive opening operation or sub-assembly assuring positive opening operation. Other versions Gold flashed contacts. Please consult our Customer Care Centre. Rugghölzli CH - Busslingen Tel. + () Fax + ()

5 Operation Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN Adaptable sub-assemblies Heads ZCK D, D with body ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S..(P) / /- / /-...(P).mm.(P).mm.mm.. ZCK SD ZCK SD ZCK SD ZCK SD..(P)..(P)..(P)..(P)..mm.mm.mm Heads ZCK D, D with body ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S.(A).(P). mm.(a) / /- / /- mm. ZCK SD ZCK SD ZCK SD ZCK SD..(P)..(P)..(P)..(P)..mm. mm Heads ZCK D, D, D with body ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S Heads ZCK D, D, D, D, D, D, D, D with body ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S Heads ZCK D (positive operation only assured with a operating lever) with body ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S Heads ZCK D, D with body ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S ZCK S ZCK SD ZCK SD ZCK SD ZCK SD..(A).(P). mm. / /- / /- mm ZCK S (body with head) Unactuated Actuated from left Actuated from right..(a). Contact operation G closed H open (A) = cam displacement (P) = positive opening point.mm.mm.(p). mm ZCK SD ZCK SD ZCK SD ZCK SD (P) (P) (P) (P) / /- / /- ZCK SD ZCK SD ZCK SD ZCK SD / /- / /- ZCK SD ZCK SD ZCK SD ZCK SD (P) (P) (P) (P) / /- / /- mm.(p) -..mm..mm.(p).(a) mm (A).mm..(P).mm..(A).(P). mm Rugghölzli CH - Busslingen Tel. + () Fax + ()

6 Dimensions Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN Adaptable sub-assemblies Plunger heads ZCK D ZCK D ZCK D ZCK D.... Rotary heads ZCK D, D, D ZCK D ZCK D ZCK D ZCK D, D, D ZCK D ZCK D () () () () (). ZCK () rod () () () () D U, L = max. max. D Ø, L = max. max. D Ø, L = max. max... Note: operating lever spindle threaded M. Multi-directional heads Bodies with contacts ZCK D ZCK D ZCK S, S, S, S, S, S, S ZCK SH, SH, SH, SH, SH, SH, SH ZCK SDp, SDpH. ().. = Ø xø.. = ZCK S, SH M ().. = Ø xø. = () tapped entry for ISO M x. or Pg. cable gland. Ø: elongated holes Ø. x.. Rugghölzli CH - Busslingen Tel. + () Fax + ()

7 Presentation, general characteristics Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN b XCK S with cable entry v With head for linear movement (plunger) Page / v With head for rotary movement (lever) Page / Environment characteristics Conformity to standards Products IEC --, EN --, UL, CSA C- n Machine assemblies IEC -, EN - Product certifications UL, CSA, CCC Protective treatment Version Standard: TC and TH Ambient air temperature For operation - + C For storage - + C Vibration resistance Conforming to IEC -- gn ( Hz) Shock resistance Conforming to IEC -- gn ( ms) Electric shock protection Class II conforming to IEC and NF C - Degree of protection IP conforming to IEC ; IK conforming to EN Repeat accuracy. mm on the tripping points, with million operating cycles for head with end plunger Cable entry Depending on model Tapped entry for n cable gland or tapped ISO M x. Materials Bodies and heads: plastic Rugghölzli CH - Busslingen Tel. + () Fax + ()

8 General characteristics (continued) Limit switches OsiSense XC Standard, format EN Conforming to CENELEC EN Contact block characteristics Rated operational characteristics XEp P XEp P a AC-; A (Ue = V, Ie = A); = A c DC-; Q (Ue = V, Ie =. A), conforming to IEC -- Appendix A, EN -- a AC-; B (Ue = V, Ie =. A); = A c DC-; R (Ue = V, Ie =. A), conforming to IEC -- Appendix A, EN -- Rated insulation voltage XEp P Ui = V degree of pollution conforming to IEC - Ui = V conforming to UL, CSA C- n XEp P Ui = V degree of pollution conforming to IEC - Ui = V conforming to UL, CSA C- n Rated impulse withstand voltage XEp P U imp = kv conforming to IEC -, IEC XEp P U imp = kv conforming to IEC -, IEC Positive operation (depending on model) NC contacts with positive opening operation conforming to IEC -- Appendix K, EN -- Resistance across terminals y mω conforming to IEC - category Short-circuit protection XEp P A cartridge fuse type gg (gl) XEp P A cartridge fuse type gg (gl) Connection (screw clamp terminals) XES Pp Clamping capacity, min: x. mm, max: x. mm XEN Pp Clamping capacity, min: x. mm, max: x. mm XES P Clamping capacity, min: x. mm, max: x. mm XEN P and XES P Clamping capacity, min: x. mm, max: x mm or x. mm Minimum actuation speed XES Pp, XES P and XES P:. m/minute XEN Pp and XEN P: m/minute Electrical durability b Conforming to IEC -- Appendix C b Utilisation categories AC- and DC- b Maximum operating rate: operating cycles/hour b Load factor:. XES Pp, XES P XEN Pp XES P AC supply / Hz a o inductive circuit DC supply c AC supply / Hz a o inductive circuit DC supply c. V / V V V.. Power broken in W for million operating Power broken in W for million operating Power broken in W for million operating Voltage V Voltage V Voltage V o W o W o W For XES Pp on a or c, NC and NO contacts simultaneously loaded to the values shown with reverse polarity. XES Ppppp XEN Ppppp. V / V V V.. Power broken in W for million operating.. Power broken in W for million operating Voltage V Voltage V o W o W.... V // V V // V V V... V V / V. V. Rugghölzli CH - Busslingen Tel. + () Fax + ()

ZCK-E65 ZCK-Y51 ZCK-Y71 ZCK-Y61 ZCK-E09 (1) ZCK-E05 ZCK-J404H29

ZCK-E65 ZCK-Y51 ZCK-Y71 ZCK-Y61 ZCK-E09 (1) ZCK-E05 ZCK-J404H29 ZCK-E ZCK-E1 ZCK-Y ZCK-Y9 ZCK-E64 ZCK-E6 ZCK-Y1 ZCK-Y3 ZCK-E63 ZCK-Y91 ZCK-E6 ZCK-Y81 ZCK-E69 ZCK-Y71 ZCK-E67 ZCK-E9 (1) ZCK-Y61 ZCK-Y41 ZCK-Y43 ZCK-E6 ZCK-E8 ZCK-Y ZCK-Y ZCK-E619 ZCK-Y11 ZCK-E ZCK-E66

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Pneumatic. PXC Limit Switches. Authorised Distributor TTS Valve Technologies Sdn Bhd

Pneumatic. PXC Limit Switches. Authorised Distributor TTS Valve Technologies Sdn Bhd Pneumatic PXC Limit Switches Limit Switches Series PXC High durability Very good repeat accuracy Design for process duty cycle Push-in or threaded connection Versatile and easily maintained Wide range

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data. Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

ELECTROMAGNETIC DISC BRAKES

ELECTROMAGNETIC DISC BRAKES ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

60 Series - General purpose relays 6-10 A. Features 60.12 60.13

60 Series - General purpose relays 6-10 A. Features 60.12 60.13 Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)

More information

HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure. General-purpose Limit Switch CSM DS_E_3_ Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog 9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C .1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20

More information

MICRO SWITCH Compact Precision Limit Switches. 14CE Series. Datasheet

MICRO SWITCH Compact Precision Limit Switches. 14CE Series. Datasheet MICRO SWITCH Compact Precision Limit Switches 4CE Series Datasheet MICRO SWITCH 4CE Series Compact Precision Limit Switches All MICRO SWITCH 4CE Series compact enclosed switches incorporate fluorocarbon

More information

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)

Application Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole) Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia. Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

Catalog. Arc Guard System TM TVOC-2

Catalog. Arc Guard System TM TVOC-2 Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

Common Features of Electromechanical Switches

Common Features of Electromechanical Switches Common Features of Electromechanical Switches Switching systems Switching elements lie at the heart of all electromechanical switching devices and must correspond to the respective application. Essentially

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,

More information

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

SKR - industry relay

SKR - industry relay SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,

More information