1 Installation instructions for contractors VIESMANN Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle VITOSOL 200-T 3/2010 Dispose after installation.
2 Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained Danger This symbol warns against the risk of injury.! Please note This symbol warns against the risk of material losses and environmental pollution. Note Details identified by the word "Note" contain additional information. Target group These instructions are exclusively designed for qualified personnel. Work on electrical equipment must only be carried out by a qualified electrician. Regulations Observe the following when working on this system All legal instructions regarding the prevention of accidents, All legal instructions regarding environmental protection The Code of Practice of relevant trade associations, All current safety regulations as defined by DIN, EN, DVGW, VDE and all locally applicable standards. a ÖNORM, EN and ÖVE c SEV, SUVA, SVTI, SWKI and SVGW Gas Safety (Installation & Use) Regulations the appropriate Building Regulation either the Building regulations, the Building Regulation (Scotland), Building Regulations (Northern Ireland), the Water Fittings Regulation or Water Bylaws in Scotland, the current I.E.E. Wiring Regulations. Working on the system Isolate the system from the power supply and check that it is no longer 'live', e.g. by removing the separate fuse or by means of a main isolator. Safeguard the system against unauthorised reconnection. 2
3 Index Installation sequence Horizontal above roof installation... 4 Installation with roof hooks... 4 Installation with mounting brackets Vertical above roof installation Installation with roof hooks Installation with mounting brackets Installation on supports Components Determining collector row clearance z Installation Horizontal installation on flat roofs Components Installation Installation on walls Components Installation Making the hydraulic connections Connecting the header casing Fitting the connection set Fitting the vacuum tubes Fitting the collector temperature sensor Installation Commissioning
4 Horizontal above roof installation Installation with roof hooks Components /2148 Roof tiles 1 Timber 38 x 58 x 2430 mm 30 x 100 x 2430 mm 2 Roof hook 3 Zinc-plated countersunk chipboard screw (Spax-s) 6 x 80 mm 4 Zinc-plated countersunk chipboard screw (Spax-s) 5 x 80 mm Slate roof 5 Roof hook 6 Zinc-plated countersunk chipboard screw (Spax-s) 6 x 80 mm Corrugated sheet roof 7 Roof hook for corrugated roofing sheet, profiles 5 and 6 8 Roof hook for corrugated roofing sheet, profile 8 4 Plain tiles 9 Roof hook 4 Zinc-plated countersunk chipboard screw (Spax-s) 5 x 80 mm For all types of roofing qw T-slot bolt qe Washer qr Hexagon nut qt Mounting rail qz Mounting rail with tube holders qu Mounting plate qi Locking bracket qo Spacer wp Retaining rubber
5 Horizontal above roof installation (cont.) Dimensions overview 102 a 81 b x 160 x 160 c d e Dimension x according to the width of the tile head. For dimensions a to e, see the following table. A Spacer B Header casing C Mounting bracket D Mounting rail with tube holders E Mounting rail F Timber, 38 x 100 mm (only for roof tiles) G Timber, 30 x 58 mm (only for roof tiles) H Roof hook 5
6 Horizontal above roof installation (cont.) Combination a mm b mm c mm d mm e mm 2 m m m 2 /2 m m 2 /3 m m 2 /2 m m 2 /3 m f Note f = 81 mm For installations without roof hooks, mounting brackets are used in place of roof hooks. Fitting roof hooks Roof tiles Observe dimensions in chapter "Dimensions overview". 6
7 Horizontal above roof installation (cont.) x x Continue with chapter "Fitting mounting rails". Slate roof Observe dimensions in chapter "Dimensions overview" Note Fit commercially available lead flashing to protect against the ingress of moisture. Continue with chapter "Fitting mounting rails". 5 7
8 Horizontal above roof installation (cont.) Corrugated sheet roof Observe dimensions in chapter "Dimensions overview". Continue with chapter "Fitting mounting rails". Ø8 A 2. 7,8 1. B A Sealing washer (on site) B Existing roof batten Plain tiles Observe dimensions in chapter "Dimensions overview"
9 Horizontal above roof installation (cont.) 30 Fitting mounting rails Information regarding fitting the rail Fit the mounting rails with tube holders offset against each other. This achieves a slope of the vacuum tubes towards the horizontal. Trim tile with angle grinder; cut off approx. 30 mm. a c b A A Header casing B B Mounting rail with tube holders Vitosol 200-T a mm b mm c mm 2 m m
10 Horizontal above roof installation (cont.) qrqe qw A qt A Roof hook 10
11 Horizontal above roof installation (cont.) 2. 2x x
12 Horizontal above roof installation (cont.) If several collectors are fitted above each other 90 2x 7. qw qeqrqo Installing the header casing Use the centring nut on the back of the header casing as a drilling guide. 12
13 Horizontal above roof installation (cont.) Continue with chapter "Making the hydraulic connections". qr qe Ø9 90 qw qu 8. Installation with mounting brackets Components For example, installation on sheet steel roofs. Use on-site fixings to secure the brackets (e.g. for standing seams). 13
14 Horizontal above roof installation (cont.) /2148 qp Mounting bracket qq Clamping bracket qw T-slot bolt qe Washer qr Hexagon nut qt Mounting rail qz Mounting rail with tube holders qu Mounting plate qi Locking bracket qo Spacer wp Retaining rubber 14
15 Horizontal above roof installation (cont.) Dimensions overview 102 a 81 b e c d A Spacer B Header casing C Mounting bracket D Mounting rail with tube holders E Mounting rail Combination a mm b mm c mm d mm e mm 2 m m m 2 /2 m m 2 /3 m m 2 /2 m m 2 /3 m
16 Horizontal above roof installation (cont.) Installation Fit mounting rails offset against each other (see page 9) Screws for mounting brackets to be supplied on site. Proceed as follows: See chapter "Fitting mounting rails". See chapter "Making the hydraulic connections". 16
17 Vertical above roof installation Installation with roof hooks Components /2148 Roof tiles 1 Timber 38 x 58 x 2430 mm 30 x 100 x 2430 mm 2 Roof hook 3 Zinc-plated countersunk chipboard screw (Spax-s) 6 x 80 mm 4 Zinc-plated countersunk chipboard screw (Spax-s) 5 x 30 mm Slate roof 5 Roof hook 6 Zinc-plated countersunk chipboard screw (Spax-s) 6 x 80 mm Corrugated sheet roof 7 Roof hook for corrugated roofing sheet, profiles 5 and 6 8 Roof hook for corrugated roofing sheet, profile 8 Plain tiles 9 Roof hook 4 Zinc-plated countersunk chipboard screw (Spax-s) 5 x 80 mm For all types of roofing qq Clamping bracket qw T-slot bolt qe Washer qr Hexagon nut qt Mounting rail qz Mounting rail with tube holders qu Mounting plate qi Locking bracket qo Spacer wp Retaining rubber 17
18 Vertical above roof installation (cont.) Dimensions overview AB C D E F G B C H K B x x Dimension x according to the width of the tile head. A Vacuum tube B Clamping bracket C Mounting rail with tube holders D Mounting rail E Roof hook F Timber, 38 x 58 mm (only for roof tiles) G Timber, 30 x 100 mm (only for roof tiles) H Mounting plate K Header casing 18
19 Vertical above roof installation (cont.) d a 2 b a e c c Note For installations without roof hooks, mounting brackets are used in place of roof hooks. Combination a mm b mm c mm d mm e mm 2 m m m 2 /2 m m 2 /3 m m 2 /3 m Fitting roof hooks Roof tiles Observe dimensions in chapter "Dimensions overview". 19
20 Vertical above roof installation (cont.) x x Continue with chapter "Fitting mounting rails". Slate roof Observe dimensions in chapter "Dimensions overview" Note Fit commercially available lead flashing to protect against the ingress of moisture. Continue with chapter "Fitting mounting rails". 5 20
21 Vertical above roof installation (cont.) Corrugated sheet roof Observe dimensions in chapter "Dimensions overview". Continue with chapter "Fitting mounting rails". Ø8 A 2. 7,8 1. B A Sealing washer (on site) B Existing roof batten Plain tiles Observe dimensions in chapter "Dimensions overview"
22 Vertical above roof installation (cont.) Trim tile with angle grinder; cut off approx. 30 mm. 230 Fitting mounting rails ,5 A Roof hook 22
23 Vertical above roof installation (cont.) 4. f qr qe qq qw qt 90 qq qz qq 3. 4x Note f = 81 mm Tube holders on opposite rails must be aligned. 23
24 Vertical above roof installation (cont.) Installing the header casing Note The tube holders on the mounting rails must be aligned with those in the header casing; where necessary, align with a piece of string. Continue with chapter "Making the hydraulic connections". Installation with mounting brackets Components For example, installation on sheet steel roofs. Use on-site fixings to secure the brackets (e.g. for standing seams). 24
25 Vertical above roof installation (cont.) /2148 qp Mounting bracket qq Clamping bracket qw T-slot bolt qe Washer qr Hexagon nut qt Mounting rail qz Mounting rail with tube holders qu Mounting plate qi Locking bracket qo Spacer wp Retaining rubber 25
26 Vertical above roof installation (cont.) Dimensions overview A B C D E B CF G D B A Vacuum tube B Clamping bracket C Mounting rail with tube holders D Mounting bracket E Mounting rail F Mounting plate G Header casing 26
27 Vertical above roof installation (cont.) Installation qt qp qw qe qr Screws for mounting brackets to be supplied on site. Proceed as follows: See chapter "Fitting mounting rails". See chapter "Making the hydraulic connections". 27
28 Installation on supports Components A 50 Ø qz 1439/2148 wp A Collector supports for angles of inclination α 25 to 50, pre-assembled with screws, washers, nuts and clamping brackets 1 Collector support 2 Base rail 3 Adjustable support, lower part 4 Adjustable support, upper part 5 Cross brace 6 Hexagon bolt M 8 x 20 7 Washer mm 8 Hexagon nut M 8 qz Mounting rail with tube holders qi Header casing qo Vacuum tube wp Retaining rubber Determining collector row clearance z If several collectors are installed behind each other, maintain distance z to prevent shading. 1. Determine angle β of insolation on 21 December (the shortest day of the year) at midday. In Germany, this angle lies between 11.5 (Flensburg) and 19.5 (Konstanz), subject to latitude. 28
29 Installation on supports (cont.) Example: Würzburg is approximately located on latitude 50 north. In the northern hemisphere, this value is deducted from a fixed angle of β = = Calculating dimension z: h = 2165 mm α = 45 β = 16.5 h h α z β α z sin (180 (α+β)) = h sin β 2165 mm sin ( ) z = sin 16.5 z = 6700 mm z Collector row distance h Collector height α Collector angle of inclination β Angle of the sun Installation Installation information Observe max. load and distance from the edge of the roof for the on-site substructure to DIN Remove any gravel or similar from the installation location, cover the surface with protective building mats and position foot support slabs A and B on top of these mats. Where possible, orient the collector array due south. Calculation of ballast and max. load on the substructure according to DIN /1986 and DIN /1975. Two foot support slabs each A and B are required respectively for each collector. For the calculation, the Viessmann "SOLSTAT" calculation program is available at 29
30 Installation on supports (cont.) Adjusting the angle of inclination α Adjust the required angle of inclination (see chapter "Components") x Fitting the collector supports Use the cross braces as drilling template. For calculating dimension z, see chapter "Determining collector row clearance z". 30
31 Installation on supports (cont.) A 3. 8x z B a b A Foot support A B Foot support B Combination a mm b mm 2 m 2 /2 m 2 900/ m 2 /3 m 2 900/ m 2 /3 m /
32 Installation on supports (cont.) Ø
33 Installation on supports (cont.) Fitting the mounting rails and header casing 8. 4x qi qz qz 7. 4x Note The tube holders on the mounting rails must be in line with those in the header casing; where necessary, align with a piece of string. Continue with chapter "Hydraulic connections". 33
34 Horizontal installation on flat roofs Components / Rawl plug S10 2 Washer 3 Hexagon screw 8 x 70 mm qq Clamping bracket qw T-slot bolt qe Washer qr Hexagon nut qt Mounting rail qz Mounting rail with tube holders qu Mounting plate wp Retaining rubber wq Mounting bracket Installation Installation information Observe max. load and distance from the edge of the roof for the on-site substructure to DIN Remove any gravel or similar from the installation location, cover the surface with protective building mats and position foot support slabs A and B on top of these mats. Where possible, orient the collector array due south. Calculation of ballast and max. load on the substructure according to DIN /1986 and DIN /1975. Two foot support slabs each A and B are required respectively for each collector. For the calculation, the Viessmann "SOLSTAT" calculation program is available at 34
35 a b c f Horizontal installation on flat roofs (cont.) Dimensions overview Note f = 81 mm A Foot support A B Foot support B Combination a mm b mm c mm 2 m m m 2 /2 m m 2 /3 m m 2 /2 m m 2 /3 m
36 Horizontal installation on flat roofs (cont.) Fitting mounting rails 4x A Foot support A B Foot support B 36
37 Horizontal installation on flat roofs (cont.) 2x x Note Tube holders on opposite rails must be aligned. 37
38 Horizontal installation on flat roofs (cont.) Installing the header casing x 6. Note The tube holders on the mounting rails must be in line with those in the header casing; where necessary, align with a piece of string. Continue with chapter "Making the hydraulic connections". 38
39 Installation on walls Components / Rawl plug S10 2 Washer 3 Hexagon screw 8 x 70 mm qp Mounting bracket qw T-slot bolt qe Washer qr Hexagon nut qt Mounting rail qz Mounting rail with tube holders qu Mounting plate qi Locking bracket wp Retaining rubber 39
40 a b c Installation on walls (cont.) Installation Dimensions overview f Note f = 81 mm Combination a mm b mm c mm 2 m m m 2 /2 m m 2 /3 m m 2 /2 m m 2 /3 m
41 Installation on walls (cont.) Fitting mounting rails Fit mounting rails offset against each other (see page 9) x x
42 Installation on walls (cont.) 5. qrqe qp qw qz qt qw qu qe qr x 90 4x x
43 Installation on walls (cont.) qz qi 2x 7. qw qeqr Installing the header casing Ø9 mm
44 192 Making the hydraulic connections Connecting the header casing Components Viesmann Armaturenfett Graisse pour robinetterie Instrument grease Lubrication Unisilkon L250L! Please note Connection pipes should not show any signs of damage. Lubricate all O-ring seals on the collectors only with the special grease provided. Installation information Click retaining clips into the groove in the connection pipes through the holes in the collector connectors. Align the header casing
45 Making the hydraulic connections (cont.) Fitting the connection set Components Viesmann Armaturenfett Graisse pour robinetterie Instrument grease Lubrication Unisilkon L250L Installation information All pipes must be cut at a right angle and deburred. Lubricate all O-ring seals only with the special grease provided. Initially turn the union nut by hand, then tighten with an open ended spanner by a further ¾ turn. Never fit annealed copper pipes onto the locking ring fittings. 45
46 Making the hydraulic connections (cont.) x x 8. 2x 1. VL RL VL RL 4. 4x 7. 2x Use the U-pipe with air vent valve only for horizontal collector installations. Click retaining clips into the groove through the holes in the collector connectors. After joining the collector array to the pipework of the solar circuit, fill the system, check the system pressure and test for leaks. "Vitosol-T" service instructions. 46
47 Making the hydraulic connections (cont.) Fitting the vacuum tubes Danger The vacuum tubes can break if insufficient care is taken. This can result in injuries. The condenser becomes very hot under insolation. Wear gloves and safety goggles. Installation information Pull the gasket only from the top of the casing cover groove. Direct the coated side of the absorber towards the sun. Ensure that no part of the thermal insulation becomes trapped. The surface of the condenser must be clean. The condenser must be positioned centrally inside the heat exchanger retainer. For roofs deviating from due south, adjust the angle of inclination of the absorber using the template provided. max. 25! Please note Never align (turn) the tubes in their locked state. This would lead to tube damage x 47
48 Making the hydraulic connections (cont.) Fitting the collector temperature sensor Installation information The first and last tubes of a collector must be secured to the twin-pipe heat exchanger with a clip. Fit the sensor near the hydraulic connections.! Please note Route the sensor lead so that it does not come into contact with the hot tubes. Route the lead through the slot in the thermal insulation. 48
49 Fitting the collector temperature sensor (cont.) x ! Please note The collectors may be damaged if the solar thermal system is not filled with heat transfer medium immediately after installation. Therefore, protect the collectors against solar irradiation by covering them up. 49
50 Installation Please note! Incorrect installation can lead to collector damage. Use only gunmetal or brass fittings and copper pipes for the installation. Never step on the collectors. Never solder on or near the collector. Position pipes so that complete ventilation is guaranteed. Install an air separator at an accessible point in the pipework (see the following diagram). Generally, copper lines in solar circuits are hard soldered or joined by press fittings. Soft solder could be weakened, particularly near the collectors, due to the max. temperatures that may occur there. Metal seal connections, locking ring fittings or Viessmann plug-in connections with double O-rings are the most suitable. If other seals such as flat gaskets are used, adequate glycol, pressure and temperature stability must be guaranteed by the manufacturer. Make all connections pressure and temperature-resistant (observe the maximum idle temperature of the collector). Never use: Teflon (inadequate glycol stability) Hemp connections (not sufficiently gas-tight) Equip systems to EN with an expansion vessel, safety valve and circulation pump. The expansion vessel must be approved in accordance with DIN The diaphragms and seals of the expansion vessel and safety valve must be suitable for the heat transfer medium. To calculate the pre-charge pressure, see the "Vitosol" service instructions. When operating without a Solar-Divicon, only use safety valves designed for 120 C, a maximum pressure of 6 bar, and which carry the "S" (Solar) designation. 50
51 Installation (cont.) P O A E B P E M D D C T F N L K G H A Collector B Solar-Divicon C Drip container D Expansion vessel E Stagnation heat sink F Shut-off valve G Filling H Manual solar fill pump K Fill valve (F, G, L) L Drain M Air separator N DHW cylinder O Solar control unit P Air vent valve Commissioning For commissioning the solar thermal system, see the "Vitosol" service instructions. 51
52 Printed on environmentally friendly, chlorine-free bleached paper 52 Viessmann Werke GmbH&Co KG D Allendorf Telephone: Fax: Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: Fax: Subject to technical modifications.
VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate
More informationVITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
More informationData Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
More informationVIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy Datasheet Part no. and prices: see pricelist VITOSOL 200-F Type SV2A/B and SH2A/B Flat-plate collector for vertical or horizontal
More informationVIESMANN. Installation and service instructions VITOTROL 100. for contractors
Installation and service instructions for contractors VIESMANN Vitotrol 100 Type UTDB-RF2 Room temperature controller with digital time switch and wireless receiver For applicability, see the last page
More information6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU
6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety
More informationPITCHED ROOF STRUCTURES
PITCHED ROOF STRUCTURES for framed and frameless photovoltaic modules Needed tools and materials: cordless screwdriver 10mm and 13mm spanners 5mm Allen key bolts, screws and tools for fixing the system
More informationInstallation Instructions
Installation Instructions for use by heating contractor Please file in Service Binder Vitosol-F Models SV, SH Flat plate solar collectors for sloped roofs, flat roofs, walls and freestanding installation
More informationInstallation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
More informationInstallation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8
. Thermomax Solar Water Heater Thermo Technologies 5560 Sterrett Place, Suite 115 Columbia, MD 21044 Thermoteks.com November 2005 Installation Manual.......... Installation Procedure for Flatroof and Ground
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationInstallation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT
Installation and Service Instructions for use by heating contractor Solar Control Module for solar connections to the Vitotronic control SM1 SOLAR CONTROL MODULE Product may not be exactly as shown IMPORTANT
More informationCOOLING SYSTEM Section Page
5 COOLING SYSTEM Section Page 5.1 COOLANT PRE-HEATER... 5-3 5.2 COOLANT PUMP NON-EGR ENGINE... 5-7 5.3 COOLANT PUMP EGR ENGINE... 5-13 5.4 FRONT CONNECTOR HOUSING NON-EGR ENGINE... 5-17 5.5 FRONT CONNECTOR
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationZenith Solar thermal 4.5m pump station Installation manual
Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationHORIZONTAL INSTALLATION
THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof
More informationInstallation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Gravity Solar System Installation Manual: This manual explains how to install a system of evacuated
More informationSolar Collector Series. Product List
Solar Collector Series List FULL COLLECTORS (MANIFOLD, TUBES & ROOF FRAME) : CSR00051 Apricus Collector : AP10 10-Way Manifold, 10 Tubes and Standard Roof Frame CSR00052 Apricus Collector : AP20 20-Way
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationCoolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
More informationInstallation and Commissioning Manual Solar Stations FlowCon Max Evolution II
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification
More informationPhoenix Solar AG. Phoenix TectoSun 3 Installation instructions
AG Phoenix TectoSun 3 Installation instructions 2 THE TECTOSUN 3 MOUNTING SYSTEM FROM PHOENIX SOLAR THE ADVANTAGES AT A GLANCE Tested by TÜV, RAL seal of uality for all components Quick and easy installation
More informationARCOBALENO SXT Flat roof and ground level mounting system with 45 angle of inclination
ARCOBALENO SXT Flat roof and ground level mounting system with 45 angle of inclination Manual use and installation Cod. 6902952 page 3 Thank you for your choice of ARCOBALENO SXT. Carefully read this manual
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationThis unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
More informationHYDRAULIC TABLE CART 500-LB.
HYDRAULIC TABLE CART 500-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic
More informationMODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK
1 565AKHU HYDRAULIC 1.22 O-RING - 2 REQUIRED UNIT 1.23 O-RING COMPLETE 1.24 TEFLON O-RING 2 REQUIRED 1.3 EXTENSION SCREW 1.3A SPRING PIN 1.4 SPRING SUPPORT 1.5 SCREW BUSHING 1.6 Y SHAPE SEAL RING 1.7 HEAD
More informationSaferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
More informationOverview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
More informationFront axle components, overview
just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,
More informationSolar heating from Viessmann: efficient systems for the utilization of solar energy
Solar heating from Viessmann: efficient systems for the utilization of solar energy At this year's ISH, Viessmann, the leading European brand for solar heating, will present: - the in-roof flat-plate collectors
More informationSustainable water heating solutions through solar systems
VIESMANN Sustainable water heating solutions through solar systems Murat Aydemir Managing Director Viessmann Middle East FZE Viessmann is a Registered Provider with The American Institute of Architects
More informationXL PREMIUM OIL COOLER KIT
-J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationVITOSOL. Solar heating systems Flat-plate and tube collectors
VITOSOL Solar heating systems Flat-plate and tube collectors 2 Vitosol Solar collectors Heat from the sun: Free energy The heating system that loves the environment The sun can radiate the annual energy
More informationINSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV. 10-19-04. General. Removal (Left and Right Forks) Kit Number 54614-05
INSTRUCTIONS -J04 REV. 0-9-04 General FLHR/C/S (Road King) FRONT END LOWERING KIT This kit is designed for installation on 00 and later FLHR/C/S Model Motorcycles. Road King models use the conventional
More informationFloat and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
More informationUBBINK SOLAR IN-ROOF SYSTEM
UBBINK SOLAR IN-ROOF SYSTEM The integrated solar mounting system Installation guide UBBINK SOLAR IN-ROOF SYSTEM Table of contents Solar In-Roof System introduction System components Installation guide
More informationPlumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
More informationOperating Instructions Drill rig DRU160
Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationCooling system components, removing and installing
Volkswagen Touareg 3.2 - Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! Hot steam may escape when opening expansion tank.
More informationINSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
More informationDANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
More informationSolar Thermal Systems
Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann
More informationConstantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
More informationFlue Installation. High Efficiency Condensing Boilers
Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION
More informationKnürr Smaract. Knürr Smaract. CompactRack
CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.
More informationSMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
More informationHYDRAULIC LIFT TABLE CART 2200-LB.
HYDRAULIC LIFT TABLE CART 2200-LB. OWNER S MANUAL WARNING: Read carefully and understand all MACHINE ADJUSTMENT AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationTHE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS Applied Energy Products Limited, Morley Way, Peterborough, PE2 9JJ, UK Telephone: +44 (0) 844 372 7761 / Fax: +44 (0) 84 372 7762 Website:
More informationAutoDome Easy II. VEZ Series. Mounting Manual
AutoDome Easy II VEZ Series en Mounting Manual AutoDome Easy II Table of Contents en 3 Table of Contents 1 Important Safety Instructions 5 2 Unpacking 7 2.1 Parts List 7 3 Description 9 4 Installing a
More information3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
More informationSERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
More informationMACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent
More informationFigure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.
Here are some pictures to show what s required when replacing the A/C compressor, expansion valve and receiver/drier on a 2001 Volvo V70. Even if you don t replace these A/C parts these pictures can help
More informationGENERAL INSTALLATION MANUAL FOR EGING PV MODULES
GENERAL INSTALLATION MANUAL FOR EGING PV MODULES PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE MODULES. PLEASE PASS ALONG THE ATTACHED USER MANUAL TO YOUR CUSTOMER. 1. INTRODUCTION This
More informationTest Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
More informationLUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
More informationS OUNTING INSTRUCTION M M o u n t i n g k i t 2 &
M O U N T I N G I N S T R U C T I O N S instructions This document is protected by copyright. The SICK AG company retains this right. Reproducing this document in whole or part is only permissible within
More informationVolkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
More informationSAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE
1 Which tool is used to correct internal hi-low when preparing a 4-in. steel pipe for welding? A. 4-in. grinder with cutting disc. B. Mini-grinder with flapper disc. C. Pencil grinder with cone stone.
More informationInstallation Instructions for Contractors. Connection Sets. Solar Twin Tube. Inox 1/2" Inox 3/4" 6 720 646 309 (2011/02) US/CA
Installation Instructions for Contractors Connection Sets Solar Twin Tube Inox 1/2" Inox 3/4" 6 720 646 309 (2011/02) US/CA Contents Contents 1 Explanation of symbols and safety information 3 1.1 Explanation
More informationDispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd. 1 The Kingspan Group Energy independent buildings for a sustainable
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...
FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE
More informationInstallation instruction of the flat solar collectors models ES1V2.0, ES1V2.65, ES2V/2.0 AL, EM2V/2.0, ES2V/2.65, ES2H/2.65 on the inclined tile roof.
Installation instruction of the flat solar collectors models ES1V2.0, ES1V2.65, ES2V/2.0 AL, EM2V/2.0, ES2V/2.65, ES2H/2.65 on the inclined tile roof. 04/2014 Get acquainted before starting the installation.
More informationSelf-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50
More informationInstallation and maintenance instructions
Installation and maintenance instructions Indirect fired domestic hot water tank Logalux ST50/ ST300/ For heating contractors Please read carefully prior to installation and maintenance. 7 747 00 883 09/006
More informationRELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN 05.2015 www.rehau.com/relazzo
Construction Automotive Industry RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE REHAU R20680 EN 05.2015 www.rehau.com/relazzo Scan the QR code and learn more: RELAZZO DECKING THE TERRACE. Installation
More informationInstallation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
More informationTurbocharger system components, servicing
21-1 Turbocharger system components, servicing Engine codes: AAZ, 1Z, AHU Observe rules of cleanliness Page 21-10 Turbocharger hoses and lines, connecting Page 21-11 WARNING! Do not re-use any fasteners
More informationCooling system components
Page 1 / 33 19-1 Cooling system components Caution! When doing any repair work, especially in the engine compartment, pay attention to the following due to clearance issues: Route lines of all types (e.g.
More informationSTEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT
More informationVolkswagen Golf 5 2004-> VW Rabbit GTI 2006->
Стр. 1 из 24 Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> 19-1 Cooling system components Warning! Hot steam may escape when opening expansion tank. Wear protective goggles and protective clothing to prevent
More information1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
More informationKNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
More informationUB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
More informationTriac Printed Circuit Board Replacement
Technical Service Bulletin: Triac Printed Circuit Board Replacement TRONIC 5000C Pro Models: WH17, WH27, WH36 Introduction Fig. 1 ELECTRICITY IS EXTREMELY DANGEROUS. TAKE EXTRA PRECAUTIONS AND ENSURE ALL
More informationInstallation Guide 2010 BMW S1000RR Full Exhaust System
Installation Guide 2010 BMW S1000RR Full Exhaust System!! THIS PRODUCT IS DESIGNED FOR USE IN CLOSED COURSE RACING AND IS NOT INTENDED FOR HIGHWAY USE!! Congratulations on the purchase of your new TaylorMade
More informationPlease also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
More informationPrice List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.
Price List Rev.2 2010 AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.com SOMMARIO INDEX SOLAR SYSTEMS... page 10 COMPONENTS
More informationPV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY
PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY Tile on-roof PV Mounting System Installation on tiles roof. Various quick roof hooks with different strength and structure are available.
More informationPower Cube Open Source Ecology Page 1. Power Cube. Version 4
Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationINSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationEZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-54 Case IH CVX 1135 CVX 1145 CVX 1155 CVX 1170 CVX 1190 CVX 1195 CVX 135 CVX 145 CVX 155 CVX 175 CVX 195 New Holland TVT
More informationIMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
More informationSpeed-Mat Rectangle Cutter
Speed-Mat Rectangle Cutter 1 Honeycomb baseboard. 2 Left hold down. 14 3 Bottom hold down. 4 4 Left / right rule. 8 5 8 5 Left / right rule pointer. 1 6 Top / bottom rule. 7 Top / bottom rule pointer.
More informationModular Locomotive System Instruction Manual for HBK8 George Body Kit
Modular Locomotive System Instruction Manual for HBK8 George Body Kit Roundhouse Engineering Co. Ltd. Units 6-10 Churchill Business Park. Churchill Road, Wheatley. Doncaster. DN1 2TF. England. Tel. 01302
More informationMikrotherm. Manual radiator valves. To be precise.
Manual radiator valves To be precise. Description HEIMEIER Mikrotherm manual radiator valves made of corrosion-resistant gunmetal, with white plastic hand wheel cap, tight-packed with protection film.
More information3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
More informationVolkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
More informationhttp://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
More informationCable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units
for Andersen Bow, Bay, and Box Projecting Window Units Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the
More information