- Polly Grant
- 7 years ago
- Views:
Transcription
1 Residential Fans & Air Purifiers
2 HOME VENTILATION SOLUTIONS 3 components of poor indoor air quality Particulates Very small solid or liquid substances, such as dormant or living organisms and inorganic or organic compounds, that are light enough to float in air. Microbial This category represents germs, viruses, and bacteria. These small organisms can only be seen through a microscope, and are present in every environment. Chemical (Gaseous) Hundreds of gaseous pollutants, covering all combustion gases and organic chemicals (VOC s), have been detected in indoor environments. Health effects vary widely and depend on the types, concentrations, frequency and duration of exposure. AIR PURIFICATION WHAT S POLLUTING THE AIR QUALITY IN YOUR HOME OR WORK PLACE? Indoor Air Quality (IAQ) has become one of today s leading health concerns, as most people spend over 80% of their time indoors. The outside environment, ventilation systems, construction materials, furniture, carpeting, paints, and cleaning solutions are a few of the many factors that contribute to the quality of indoor air. The ventilation system has been cited as a prime contributor to Sick Building Syndrome. This can be due to poor design, improper maintenance, or incorrect operation. It may even be as simple as a change from an initial home or office layout, which can affect system efficiencies. It is important to distinguish between Sick Building Syndrome and Building Related Illnesses: Building Related Illnesses are identifiable, and can be attributed directly to specific airborne contaminants, such as Legionnaire s Disease. Sick Building Syndrome is used to describe a situation in which those spending extended time in a building, such as daily employment, report or experience acute on-site discomfort. Providing better indoor air quality is everyone s responsibility. There are many factors that we can control to help provide better indoor air quality and a healthier building: Building and decorating with Green Products Eliminating harmful chemicals used for everyday cleaning Incorporating proper ventilation methods Installing an air purification system such as CX1000 or CX3000GS FAN OPTIONS & ACCESSORIES CX1000 Portable Air Purifier CX1000-RF Filter Set CX3000GS Ducted Air Purifier CX3000-RFGS MERV-11 Filter
3 AIR PURIFIERS CX AIR PURIFIERS CX Air Purifiers are the most advanced in the world, dealing with all facets of air purification: Particle Removal Chemical Neutralization Living Organism Abatement Using patented technology, CX Air Purifiers remove airborne particles, neutralize odors and chemicals, and render germs, viruses and bacteria harmless. Pollen Pet Dander Germs Viruses Cleaning Chemicals Tobacco Smoke Environmental Pollutants Bacteria CX Air Purifiers: Create a cleaner environment Promote health & wellness Alleviate fatigue & headaches Ease breathing problems Reduce asthma, hay fever & sinus problems Control pet odors & dander Cut dust & cleaning requirements Relieve sore throats, runny noses & sneezing Photo-Catalytic Oxidation CX Air Purifiers incorporate patented Photo-Catalytic Oxidation technology, using UVC light to activate a highly reactive catalyst. This process converts harmful and toxic compounds into benign constituents, such as water and carbon dioxide. Easy Maintenance CX Air Purifiers are designed for easy maintenance to ensure peak performance at all times. Built-in electronic service lights indicate when filters and UVC lamps require replacement. Electronic Sensor CX1000 Portable Air Purifiers feature an electronic sensor that constantly monitors air quality. Airflow automatically increases to compensate for periods of unusually high chemical activity or particle count. Warning lights signal the presence of toxic chemicals and fumes well before they reach dangerous levels or become detectable to the human senses. MODEL CX1000 Portable Air Purifier CX3000GS Ducted Air Purifier DIMENSIONS 21.3 w x 19.0 h x 8.0 d 25.5 w x 21.0 h x 10.0 d WEIGHT 23 lbs. 26 lbs. MAXIMUM AIRFLOW 265 cfm 2,170 cfm POWER CONSUMPTION 110 watts 45 watts VOLTAGE 1/120V/60 1/120V/60 BLOWER Backward-curved motorized impeller N/A UVC LAMP(S) 10 watts (2) 22 watts per bulb (44 watts total) MICROWATTS AT SURFACE PER CM 2 16,000 21, ,125 UV RANGE 254 NM (germicidal) 254 NM (germicidal) FILTERS 5 micron pre-filter; 0.3 micron hospital grade HEPA filter Electrostatic needled fiber MERV-11 1ST STAGE GAS TREATMENT LAYER Activated carbon N/A 2ND STAGE GAS TREATMENT LAYER Activated carbon N/A APPLICATION 1,000 sq. ft. (automode) 3,000 sq. ft. SERVICE INTERVAL* UVC lamp 1 year, filters 2 years UVC lamp 1 year, filters 6 months CATALYST Metal Oxides Metal Oxides WARRANTY 2 years excluding lamp and filters 2 years excluding lamps and filters *SERVICE INTERVALS ARE SUBJECTIVE TIMES AND MAY FLUCTUATE BASED ON ENVIRONMENT.
4 AIR PURIFIERS CX1000 PORTABLE AIR PURIFIER The CX1000 Portable Air Purifier is designed to remove airborne particles, neutralize chemicals, and abate living organisms. CX1000 Portable Air Purifier uses a five-stage process to purify indoor air: 1. Treated Pre-Filter - Removes Particles to 5 Microns 2. Activated Carbon Filters (2) - Reduce Toxic Chemicals and Gases 3. Hospital Grade HEPA Filter - Purges Allergens to 0.3 Microns 4. Reactive Catalyst - Neutralizes VOC s, Toxic Chemicals, and Odors 5. UVC Light - Renders Germs, Viruses, and Bacteria Harmless CX1000 REPLACEMENT PARTS CX1000-RFL CX1000-RF CX1000-RL CX1000-PF CX1000-HF 2 Year Kit - 2 Filter Sets + 2 UVC Lamps Filter Set UVC Lamp (1 Only) Pre-Filter HEPA Filter CX1000 Portable Air Purifier Low noise, high efficiency, backward-curved motorized impeller 1. Air inlet grille with safety lock 2. Pre-filter 3. 1st stage gas adsorption layer 4. 2nd stage gas adsorption layer 5. Hospital grade HEPA filter 6. High impact ABS plastic 7. Photo-catalytic converter 8. High output germicidal UVC lamp 9. Air outlet grille with safety lock See page 25 for complete specifications. Computerized Electronic Controls CATALYTIC AIR PURIFICATION Air Quality VOC Sensor Square Square Feet Room Size/Fan Speed Meters Air Filter Service UV Lamp Service Reset Reset Power Fan Speed Sleep Mode CX1000 electronic controls monitor air quality and feature an infrared motion detector and toxic chemical sensor. Electronic Sensors detect: * Aerosols * Chemicals * Pesticides * Industrial Pollution * Smog * Carbon Monoxide * Ozone * Tobacco Smoke * Dust * VOC s
5 AIR PURIFIERS CX3000GS DUCTED AIR PURIFIER The CX3000GS Ducted Air Purifier is rated for use at standard ambient air temperatures and designed to operate with any air-conditioning or heating system, up to five tons in size. CX3000GS Ducted Air Purifier uses a four-stage process to purify indoor air: 1. Electrostatic MERV-11 Filter - Removes Allergens to 0.3 Microns 2. Reactive Catalyst - Neutralizes VOC s, Toxic Chemicals, and Odors 3. UVC Light - Renders Germs, Viruses, and Bacteria Harmless 4. Negative Ions and Activated Oxygen - Keep Air Fresh and Clean CX3000GS REPLACEMENT PARTS CX3000-RFLGS 1 Year Kit - 2 Filters + 2 UVC Lamps CX3000-RFGS Filter CX3000-RLGS UVC Lamps (Set of 2) CX3000-ARGS Furnace Adapter Ring CX3000GS Ducted Air Purifier 1. Electrostatically charged needled fiber MERV-11 filter 2. Powder coated Paint-Loc steel case 3. High output germicidal UVC lamps 4. Rust-proof gold zinc plated pull out case 5. Cabinet locks 6. Quick disconnect power cord 7. Photo-catalytic converter - 70 sq. ft. of surface area 8. Sight ports to verify lamp operation 9. Computerized service panel See page 25 for complete specifications. Performance Data CX3000GS AIRFLOW & RESISTANCE DATA Airflow (cfm) Resistance (in. wg) Air Velocity (fpm) ( )
6 Industrial Fans & Blowers OEM Solutions & Custom Fans Commercial Fans & Dampers Residential Fans & Air Purifiers Residential Fans & Air Purifiers Continental Fan Manufacturing Inc. 203 Eggert Road Buffalo, New York Continental Fan Canada Inc Matheson Blvd E Mississauga, Ontario L4Z 3E Continental Fan Manufacturing Inc Executive Blvd. Dayton, Ohio Distributed by: Residential-1510 better AIRFLOW by DESIGN TM
There are several types of air cleaning devices available, each designed to remove certain types of pollutants.
Please Note: EPA neither certifies nor recommends particular brands of home air cleaning devices. While some home air cleaning devices may be useful in some circumstances, EPA makes no broad endorsement
More informationRobert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade
Robert McCabe Director, Health Care Solutions HTS Chicago Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Biography Robert McCabe has been involved in commercial
More informationindoor Air quality products Air Filtration Ventilation Purification Humidification
indoor Air quality products Air Filtration Ventilation Purification Humidification how clean is the air in your home? According to the Environmental Protection Agency (EPA), American homeowners spend about
More informationMake your home a healthier home
Whole House Germicidal Ultraviolet Air Treatment For Healthier Living Make your home a healthier home Whole House Germicidal UV Air Treatment UltraMAX uses UV light to kill MILLIONS of bacteria, viruses,
More informationTrane CleanEffects. Patented technology. Superior performance. READ ONLY
Trane CleanEffects Patented technology. Superior performance. Trane CleanEffects is unlike anything else out there. So is the air it produces. Today s air needs tomorrow s air cleaning system. There may
More informationSun-Pure Air Purifier
Sun-Pure Air Purifier Model SP-20 User s Guide SP20 REVC Manufactured by Ultra-Sun Technologies Corona, California Ultra-Sun Technologies Corona, California U.S.A. IMPRTANT SAFETY INSTRUCTINS Always unplug
More informationHVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.
HVAC Systems and Indoor Air Quality Douglas K. Spratt, M.Sc., P.Eng. The 5 Senses Architecture Electrical Structural Mechanical Hearing Seeing Smelling Feeling Tasting HVAC Systems are Dynamic Heat Gains
More informationTHE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM
1 Application Note AT-102 THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM Lawrence B. Kilham 1 and Randall M. Dodd 2 1 Eco Sensors, Inc. Santa Fe, New Mexico, USA larry@ecosensors.com
More informationUser s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
More informationIndoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY
Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. QUALITY AIR STARTS HERE. AccuExchange Energy Recovery Ventilator Improve your home s indoor environment by exchanging stale
More informationBreathing The Air In Your Home Is Like Living In A Closed Jar. It s Enough To Make You Sick.
Breathing The Air In Your Home Is Like Living In A Closed Jar. It s Enough To Make You Sick. Introducing A Fresh Approach To Indoor Air Quality: ConsERV TM Blows The Lid Off Indoor Air Pollution - You
More informationHow to Choose An Air Filter For Your Boat
How to Choose An Air Filter For Your Boat That Will Reduce Diesel Fumes, Smoke and Odors L-2395 Rev. 1-07-06 Air Filtration Fundamentals Air filters are devices that capture dust and other contaminants
More informationTOTALINE UV AIR PURIFIERS
TOTALINE UVC GERMICIDAL AIR PURIFIERS The Totaline UVC (Germicidal) Air Purifiers are designed to work with the ventilation system to reduce airborne contaminants such as legionella, molds, bacterial and
More informationfloater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL
floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL WHAT IS AN ECO AIR COOLER? The ECO AIR COOLER uses evaporative cooling to provide an airflow that is cooler than the
More informationToday, healthcare facilities must be prepared to face
Alternate Methods for USING GERMICIDAL UV-C Disinfection Lamps TO SUPPLEMENT HEPA Filtration By Dave Shagott Today, healthcare facilities must be prepared to face potential large-scale threats from chemical,
More informationElectrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering
Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering HVAC system air filter upgrades are one way contractors can simultaneously increase
More informationA. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
More informationVentilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling 2 Ductless Ventilation & Fresh Air Solutions We can fill your home with healthy, fresh air Indoor Air Pollution is real, and it
More informationHEALTHY CLIMATE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS
AIR CLEANERS/ FILTERS 504,887M 04/2010 HEALTHY CLIMATE HEPA BYPASS AIR FILTRATION SYSTEM HOMEOWNERS MANUAL & DEALER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE MODELS HEPA-20, HEPA-40, HEPA-60 Rules
More informationInstallation Instructions
Installation Instructions Accessory Ultraviolet (UV) Germicidal Lamp 1 & 2 Lamp Models 115-v & 208/230-v UV Lamp C03009 Fig. 1 Two Lamp Model UV Lamp NOTE: Read the entire instruction manual before starting
More informationAir Quality Control Systems For Public & Shared Spaces
Air Quality Control Systems For Public & Shared Spaces THE AIR WE BREATHE MATTERS Both proper cleaning techniques and providing a touch-free environment are two ways to reduce the risk of cross contamination
More informationTake Action on Asthma. Environmental triggers of asthma and allergies
Take Action on Asthma Environmental triggers of asthma and allergies What are asthma and allergies? They are both conditions where the body reacts to substances commonly found in the air. Asthma is a very
More informationUses No Chemicals. Ozone Reverts Back to Oxygen. Eliminates Odor Electronically. Operates Unattended. Retards Bacterial Growth. Rapid Removal of Odors
Sonozaire Odor Neutralizers are industrial ozone generators for odor control and air purification. Howe-Baker and our distributors have served the odor control business with the Sonozaire models since
More informationInstallation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:
Installation Instructions Ultra-Violet Air Purifier Residential/Commercial Duct Installation Applications - RX4000, RX4000B, RX1700 SAFETY CONSIDERATIONS Installation and servicing of air-conditioning
More informationGENANO 4500 MEDICAL AIR PURIFICATION DEVICE
GENANO AIR PURIFICATION TECHNOLOGY GENANO 4500 MEDICAL AIR PURIFICATION DEVICE OPERATING INSTRUCTION 1 GENANO LTD Kimmeltie 3 FI- 02110 Espoo, Finland Tel + 358 9 7743 870 Fax + 358 9 7533 130 www.genano.fi
More informationAccuClean. For Air That s As clean READ ONLY
AccuClean For Air That s As clean as it is comfortable. Why is American Standard AccuClean air filtration better than the rest? Cleaner air starts with better airflow. Thanks to the patented technology
More informationInstallation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG
Installation and Operating Manual Model F1800C Model F1800PG Model F180C Model F180PG Model F1806C Model F1806PG www.ipsystemsusa.com Contents Safety Warnings... Items supplied... Description... Installation...4
More informationOASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
More informationAutomotive Air Quality Sensors: industrial innovations to protect people s health
Pioneering sensor and detector technology Automotive Air Quality Sensors: industrial innovations to protect people s health COST Action TD1105 3 rd Management Committee Meeting Barcelona, Spain, 21st June
More informationImproving Indoor Air Quality on a Tight Budget
Improving Indoor Air Quality on a Tight Budget The HVAC system serving our shelter was outdated, extremely inefficient, and constantly malfunctioning, so it was time for new equipment. I researched information
More informationREME HALO by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System
REME HALO by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System Thank you for purchasing the REME HALOTM by RGF Environmental Group, Inc. We are confident this system
More informationCoway Air Purifier AP-1008DH
Coway Air Purifier AP-1008DH This product is for domestic use only.it cannot be used in an overseas country where the power voltage is different. Warranty card is included in this user s manual. Read and
More informationSL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
More informationWaste Air Cleaning System. Effective reduction of: Pollutants Odours Solvent emissions
Waste Air Cleaning System Effective reduction of: Pollutants Odours Solvent emissions The Problem Waste-Air Pollution n The cleaning of polluted waste air is an up-to-the-minute topic for many companies.
More informationPEOSH. Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview. Eric Weren, MSIH
PEOSH Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview Eric Weren, MSIH Public Employees Occupational Safety and Health Unit IAQ Asthma-Friendly
More informationLaminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
More informationFederation of European Heating, Ventilation and Air-conditioning Associations
Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu info@rehva.eu Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 Use of
More informationOwner s Manual Model 5000 Safety, Operating and Maintenance Instructions
Electronic Air Cleaner 90-1147 Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions READ AND SAVE THIS MANUAL WARNING 120 Volts may cause serious injury from electrical shock. Disconnect
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationThe Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO
The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3
More informationFans That Sense & Extract Volatile Organic Compounds and Humidity
Premium Choice Ventilation Fans Featuring Fans That Sense & Extract Volatile Organic Compounds and Humidity Indoor Air Quality Concerns Today s homes are built to be tighter and more energy efficient than
More informationFume Extraction: Guide to Safely Managing Solder Fumes in the Workplace
Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace Our thanks to OK International for allowing us to reprint the following. Why do we need fume extraction? Today s Electronics workplace
More informationWORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designer/Signature:
More informationIntelli-Pro Air Purifier (Model: XJ-3800)
Intelli-Pro Air Purifier (Model: XJ-3800) Instruction Manual (Please read before using air purifier) Surround Air Division Indoor Purification Systems, Inc. 334 Marshall Way, Suite C Layton, Utah 84041
More informationWildfire Smoke and Your Health
PUBLIC HEALTH DIVISION http://public.health.oregon.gov Wildfire Smoke and Your Health When smoke levels are high, even healthy people may have symptoms or health problems. The best thing to do is to limit
More informationOwner's Manual Air-Purifier MK-B1000 Air Cleaning Expert 110V Model
Owner's Manual Air-Purifier MK-B1000 Air Cleaning Expert 110V Model Quick Reference Table of Contents How the Air-Purifier MK-B1000 works (pg.2) Getting to Know Your New Air-Purifier MK-B1000 (pg.2).location
More informationIndoor Air Quality. 2. Test and identify sources that contribute to poor indoor air quality.
Why is indoor air quality a concern? Safe air quality, both indoors and outdoors, is very important for health. In addition to poor outdoor air quality, indoor air quality is also a concern. Some examples
More informationSpecification. Indoor Air Quality Management
GREENGUARD Environmental Institute 2211 Newmarket Parkway, Suite 110 Marietta, GA 30067 1.800.427.9681 Specification Indoor Air Quality Management This Master Specification section is intended for use
More informationCOWAY AIR PURIFIER SYSTEM. HEALTH HEALTH TECHNOLOGY ASSESSMENT SECTION (MaHTAS) SECTION 018/2011
COWAY AIR PURIFIER SYSTEM HEALTH HEALTH TECHNOLOGY ASSESSMENT SECTION (MaHTAS) SECTION MEDICAL DIVISION MEDICAL MINISTRY DEVELOPMENT OF HEALTH MALAYSIA DIVISION MINISTRY OF HEALTH 018/2011 MALAYSIA 018/2011
More information+by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System
REME TM +by RGF A Guardian Air Purification System New Advanced Environmental Air Treatment System Thank you for purchasing the REME TM + By RGF Environmental Group, Inc. We are confident this system will
More informationStainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.
Product Sampler #1 Laminar Flow Hoods / Laminar Flow Cabinets: 1- Benchtop Vertical Laminar Flow Hoods- Air Recirculation Available s: Clean Bench Class 100 Bench-top Vertical Laminar Flow Hoods with Air-recirculation
More informationINDOOR AIR QUALITY INTRODUCTION WHAT ARE THE SYMPTOMS OF SICK BUILDING SYNDROME? WHEN DID POOR INDOOR AIR QUALITY BECOME A PROBLEM?
INDOOR AIR QUALITY Public Employees Occupational Safety and Health Program Richard J. Codey Acting Governor November, 2004 INTRODUCTION The average person sends approximately 90% of their time indoors.
More informationIEQ-15 Air Distribution System
AIM OF CREDIT To encourage and recognise the design and maintenance of air distribution systems that minimise the risk of particulate and microbial contamination to the internal air supply. CREDIT CRITERIA
More informationWHY IS BREATHING SO IMPORTANT?
You need to breathe to stay alive. But how clean is the air you breathe? If you breathe dirty air, you are more likely to develop health problems and become ill. Plants and animals need clean air too.
More informationCamfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality
Camfil Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality Most non-practitioners notice the HVAC system when it is too hot, or too cold, or in other ways not working
More informationIndoor air quality monitoring made easy
Indoor air quality monitoring made easy with the Fluke 985 Particle Counter Application Note Introduction Energy savings is top of facilities owners agenda. HVAC system tends to be the largest contributor
More informationChanging Carpet Care Forever
Changing Carpet Care Forever Faster, Cleaner, Greener. Pro Series Recycling Extractors Portable, Professional-Grade, Moisture-Controlled Cleaning One Machine Does it All CFR s portable Pro-500 and Pro-750
More informationSection 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU
Automatic Temperature Control Diagnosis and Repair Diagnosis of Automatic A/C Systems The most common automatic A/C system malfunctions tend to be the result of basic air conditioning problems. These problems
More informationDuctless Spray Booth Series
Sentry Air Systems, Inc. Ductless Spray Booth Series A Respiratory Safety Engineering Control: Ductless Benchtop Hooded Enclosures for the extraction and purification of aerosol spray paint fumes & particulate.
More informationEnvironmental Monitoring of Clean Rooms
Environmental Monitoring of Raul Duarte President DDK Scientific, Corp. Copyright DDK Scientific, Corp. 2008, 2009, DDK Scientific, Corp. Proprietary A manufacturing facility for pharmaceutical products
More informationA Breath of Poor Air: Inspecting Indoor Air Quality in the Classroom Ashley Schopieray
INTRODUCTION A Breath of Poor Air: Inspecting Indoor Air Quality in the Classroom Ashley Schopieray In this lesson students will learn about IAQ (indoor air quality) and the substances that could be polluting
More informationInnovation #9/12. of all Formaldehyde for up to
Innovation #9/12 of all Formaldehyde for up to Gyproc Activ Air Benefits of Activ Air Improves the indoor air quality, providing healthier interior environments Permanently reduces Formaldehyde and other
More informationECHO System for Basements
ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton
More informationBasics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
More informationConstruction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP
Construction Indoor Air Quality Management Plans for LEED Matt Gregg, PE, LEED AP Agenda What is a Construction IAQ Management Plan? What are the LEED Requirements? What is the Mechanical Contractor s
More informationMold and Indoor Air Quality in Schools. University of Nebraska Lincoln Extension
Mold and Indoor Air Quality in Schools University of Nebraska Lincoln Extension Indoor Air Quality (IAQ) Air quality can be affected by many compounds and organisms Molds and other indoor air pollutants
More informationOIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br
OIL-X EVOLUTION ENGINEERING YOUR SUCCESS. OIL-X EVOLUTION High Efficiency Compressed Air Filtration OIL-X EVOLUTION is a range of high efficiency compressed air filters consisting of coalescing filter
More informationPOLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES
POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES Ecole Nationale Supérieure de Chimie Avenue du Général Leclerc, Campus de Beaulieu 35700 Rennes, France Tel 33 (0)2 23 23 80 02 Fax 33 (0)2 23 23 81
More informationKompressoren. Compressed Air Filters PF/DF/MF/SF/AF
Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake
More informationApplication Note AT-103. Ozone and Its Measurement in Fire Restoration. A Presentation to the National Institute of Disaster Restoration
Application Note AT-103 Ozone and Its Measurement in Fire Restoration A Presentation to the National Institute of Disaster Restoration A Division of ASCR International Vancouver, BC, Canada June 26, 1998
More informationWhy Insurers Should Approve the Use of Portable Air Scrubbers on Every Water Damage Remediation Job
605 Satellite Blvd., Suite 300 Suwanee, GA 30024 678.889.4200 FAX 678.889.4201 SALES 800.634.9091 www.abatement.com Why Insurers Should Approve the Use of Portable Air Scrubbers on Every Water Damage Remediation
More informationPlease read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
More informationFTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
More informationStandard Heating and Air, Inc Committed to Excellence
Since 1973 Our Mission Statement To maintain our position as a leader in the industry by building a team of professionals focused on quality and integrity who consistently exceed the expectations of our
More informationDehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
More informationBuilding and Grounds Maintenance Checklist
Building and Grounds Maintenance Checklist Name: School: Room or Area: Date Completed: Signature: Instructions 1. Read the IAQ Backgrounder and the Background Information for this checklist. 2. Keep the
More informationTHE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS
THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS INDOOR AIR QUALITY INSTRUMENTS UNDERSTANDING, ACCELERATED BREATHE A LITTLE EASIER WITH TSI Indoor air quality is a growing concern. With the increasing
More informationRadford University. Indoor Air Quality Management Plan
Radford University Indoor Air Quality Management Plan Spring 2015 Introduction Concerns with Indoor Air Quality (IAQ) have increased since energy conservation measures were instituted in office buildings
More informationCommercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER
Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models Up to 17.0 SEER, Up to 12.8 EER SAVING ENERGY WITH INTELLIGENCE Designed to intelligently achieve the lowest total cost of ownership Energence
More informationBC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
More informationIntroduction to Use of UV Light For the Control of Air Handler Contamination. What is UVGI or Ultraviolet Light?
Introduction to Use of UV Light For the Control of Air Handler Contamination By Chris Willette Since the energy crisis of the 70 s, we have been forced to build our homes tighter and tighter to save on
More informationIMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER
To Buy: Visit sylvane.com or call (800) 934-9194 For Product Support: Contact Kaz Inc. at 1-800-477-0457 DOCTOR S CHOICE ALLERGEN REMOVER For Model Series HPA-24X IMPORTANT SAFETY INSTRUCTIONS READ AND
More informationDuct Design. Presented by Dave Janquart
Duct Design Presented by Dave Janquart Overview of Topics Duct design Duct insulation SMACNA Standards Factors Influencing Duct Design Equipment Losses Air Velocity Duct Material Duct Size & Shape Length
More informationChapter 12 Industrial Ventilation
Chapter 1 Industrial Ventilation Introduction Industrial Ventilation is an important method for reducing employee exposures to airborne contaminants. Ventilation is used to reduce or remove contaminates
More informationSENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR. www.sentryair.com 1.800.799.
SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR 1.800.799.4609 www.sentryair.com Pharmaceutical Compounding Safety Solutions Sentry Air Systems
More informationIH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
More informationHow to Reduce Your Exposure to Chemicals at Home, Work, and Play
How to Reduce Your Exposure to Chemicals at Home, Work, and Play You come into contact with chemicals every day. This is called chemical exposure. Although some chemical exposures are safe, others are
More informationSection 1: Identification. GLO GERM POWDER All colors
Glo Germ Company PO Box 537 Moab, Utah 84532 Safety Data Sheet (SDS) Section 1: Identification GLO GERM POWDER All colors Emergency & Information Telephone Numbers 1-800-842-6622 Glo Germ M-F 9 am -5 pm
More informationIEQ Management Plan. Denver Museum of Nature and Science ECF Addition
IEQ Management Plan GH Phipps Construction Companies 5995 Greenwood Plaza Blvd., Suite 100 Greenwood Village, Colorado 80111-4710 303.571.5377 PHONE www.ghphipps.com Denver Museum of Nature and Science
More informationyork air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
More informationHEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions
HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom Frequently Asked Questions What is a negative air machine and why do I need one?
More informationMechanical Systems Competency 1.20
Competency 1.20 Mechanical systems personnel shall demonstrate a working level knowledge of the safety and health fundamentals of mechanical systems and/or components. 1. Supporting Knowledge and Skills
More informationStaff shall ensure that airflow is not obstructed by the blocking of ventilators with posters, furniture, books, or other obstacles.
1 Environmental Safety AR 3514 The Superintendent may designate and train one or more employees to oversee and coordinate the district's environmental safety program(s). The responsibilities of the coordinator(s)
More informationWhy Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program
Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Indoor air quality Workers and students spend about half their waking hours at work or school. Therefore, maintaining adequate indoor air quality
More informationIndoor Air Quality- What You Need to Know
Indoor Air Quality- What You Need to Know Overview Indoor air quality (IAQ) concerns present ever-mounting problems to facility managers and health and safety personnel. From toxic mold to carbon dioxide
More informationINDOOR AIR QUALITY MEASUREMENT IN SERVER AND BATTERY ROOMS IN ICT COMPANIES IN MACEDONIA
INDOOR AIR QUALITY MEASUREMENT IN SERVER AND BATTERY ROOMS IN ICT COMPANIES IN MACEDONIA N.Koteli 1, M.Ivanova 1, K. Mitreski 1 1 Laboratory for Eco-informatics, Faculty of Computer Science and Engineering
More informationEMERGENCY VAPOR SCRUBBER SYSTEMS
EMERGENCY VAPOR SCRUBBER SYSTEMS Toxic gases such as chlorine, sulfur dioxide and ammonia are commonly used for water and wastewater treatment, and in many industrial fabrication processes. The Uniform
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationData Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?
Data Bulletin April 2001 Raleigh, NC, USA Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW Variable frequency drives are available from manufacturers as enclosed engineered
More informationHVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
More information