Simplicity of catalogue numbers

Size: px
Start display at page:

Download "Simplicity of catalogue numbers"

Transcription

1 Simplicity of catalogue numbers

2 Compact NSX Catalogue numbers Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection C-1 Wiring diagrams D-1 Additional characteristics E-1 NSX100 to 250 F-3 NSX400 to 630 F-29 Glossary G-1 F-1

3 F-2

4 Compact NSX Compact NSX100 to 250 Contents NSX100/160/250B: complete fixed/fc device Compact NSX100/160/250B (25 ka 380/415 V) F-4 Vigicompact NSX100/160/250B (25 ka 380/415 V) F-5 NSX100/160/250F: complete fixed/fc device Compact NSX100/160/250F (36 ka 380/415 V) F-6 Vigicompact NSX100/160/250F (36 ka 380/415 V) F-8 NSX100/160/250N: complete fixed/fc device Compact NSX100/160/250N (50 ka 380/415 V) F-9 NSX100/160/250H: complete fixed/fc device Compact NSX100/160/250H (70 ka 380/415 V) F-11 NSX100/160/250NA: complete fixed/fc device Compact NSX100/160/250NA F-13 NSX100/160/250B/F/N/H/S/L: fixed/fc device based on separate components Compact and Vigicompact F-14 Trip unit accessories Compact and Vigicompact NSX100/160/250 F-16 Installation and connection Compact and Vigicompact NSX100/160/250 F-17 Accessories Compact and Vigicompact NSX100/160/250 F-18 Monitoring and control, test tools Compact and Vigicompact NSX100/160/250 F-27 F-3

5 NSX100/160/250B: complete fixed/fc device Compact NSX100/160/250B (25 ka 380/415 V) DB DB DB Compact NSX100/160/250B With thermal-magnetic trip unit TM-D Compact NSX100B (25 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM16D LV LV LV LV TM25D LV LV LV LV TM32D LV LV LV LV TM40D LV LV LV LV TM50D LV LV LV LV TM63D LV LV LV LV TM80D LV LV LV LV TM100D LV LV LV LV Compact NSX160B (25 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM80D LV LV LV LV TM100D LV LV LV LV TM125D LV LV LV LV TM160D LV LV LV LV Compact NSX250B (25 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM125D LV LV LV LV TM160D LV LV LV LV TM200D LV LV LV LV TM250D LV LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Compact NSX100B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Compact NSX160B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV Compact NSX250B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A (LSI protection, ammeter) od Compact NSX100B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 40 LV LV LV LV Compact NSX160B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 100 LV LV LV LV Compact NSX250B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 E (LSI protection, energy meter) With electronic trip unit Micrologic 6.2 A (LSIG protection, ammeter) With electronic trip unit Micrologic 6.2 E (LSIG protection, energy meter) F-4

6 NSX100/160/250B: complete fixed/fc device Vigicompact (25 ka 380/415 NSX100/160/250B V) DB Vigicompact NSX100/160/250B With thermal-magnetic trip unit TM-D Vigicompact NSX100B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV Vigicompact NSX160B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV Vigicompact NSX250B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Vigicompact NSX100B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Vigicompact NSX160B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV LV LV Vigicompact NSX250B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A or 5.2 E (LSI protection, ammeter or energy meter) DB F-5

7 NSX100/160/250F: complete fixed/fc device Compact NSX100/160/250F (36 ka 380/415 V) DB DB DB Compact NSX100/160/250F With thermal-magnetic trip unit TM-D Compact NSX100F (36 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM16D LV LV LV LV TM25D LV LV LV LV TM32D LV LV LV LV TM40D LV LV LV LV TM50D LV LV LV LV TM63D LV LV LV LV TM80D LV LV LV LV TM100D LV LV LV LV Compact NSX160F (36 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM80D LV LV LV LV TM100D LV LV LV LV TM125D LV LV LV LV TM160D LV LV LV LV Compact NSX250F (36 ka at 380/415 V) 4P 3d 4P 4d TM125D LV LV LV LV TM160D LV LV LV LV TM200D LV LV LV LV TM250D LV LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Compact NSX100F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Compact NSX160F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV Compact NSX250F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A (LSI protection, ammeter) od Compact NSX100F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 40 LV LV LV LV Compact NSX160F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 100 LV LV LV LV Compact NSX250F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 E (LSI protection, energy meter) With electronic trip unit Micrologic 6.2 A (LSIG protection, ammeter) With electronic trip unit Micrologic 6.2 E (LSIG protection, energy meter) F-6

8 NSX100/160/250F: complete fixed/fc device (cont.) Compact NSX100/160/250F (36 ka 380/415 V) (cont.) Compact NSX100/160/250F With magnetic trip unit MA Compact NSX100F (36 ka at 380/415 V) MA2.5 LV MA6.3 LV MA12.5 LV MA25 LV MA50 LV MA100 LV Compact NSX160F (36 ka at 380/415 V) MA100 LV MA150 LV Compact NSX250F (36 ka at 380/415 V) MA150 LV MA220 LV With electronic trip unit Micrologic 2.2-M (LS O I motor protection) Compact NSX100F (36 ka at 380/415 V) 25 LV LV LV Compact NSX160F (36 ka at 380/415 V) 100 LV LV Compact NSX250F (36 ka at 380/415 V) 150 LV LV With electronic trip unit Micrologic 6.2 E-M (LSIG motor protection, energy meter) DB DB F-7

9 NSX100/160/250F: complete fixed/fc device Vigicompact (36 ka 380/415 NSX100/160/250F V) DB Vigicompact NSX100/160/250F With thermal-magnetic trip unit TM-D Vigicompact NSX100F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV Vigicompact NSX160F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV Vigicompact NSX250F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Vigicompact NSX100F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Vigicompact NSX160F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV LV LV Vigicompact NSX250F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A or 5.2 E (LSI protection, energy meter) DB F-8

10 NSX100/160/250N: complete fixed/fc device Compact NSX100/160/250N (50 ka 380/415 V) DB DB DB Compact NSX100/160/250N With thermal-magnetic trip unit TM-D Compact NSX100N (50 ka at 380/415 V) 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV Compact NSX160N (50 ka at 380/415 V) 4P 3d 4P 4d TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV Compact NSX250N (50 ka at 380/415 V) 4P 3d 4P 4d TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Compact NSX100N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Compact NSX160N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV Compact NSX250N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A (LSI protection, ammeter) M d Compact NSX100N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 40 LV LV LV LV Compact NSX160N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 100 LV LV LV LV Compact NSX250N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 E (LSI protection, energy meter) With electronic trip unit Micrologic 6.2 A (LSIG protection, ammeter) With electronic trip unit Micrologic 6.2 E (LSIG protection, energy meter) F-9

11 NSX100/160/250N: complete fixed/fc device (cont.) Compact NSX100/160/250N (50 ka 380/415 V) (cont.) Compact NSX100/160/250N With magnetic trip unit MA Compact NSX100N (50 ka at 380/415 V) MA2.5 LV MA6.3 LV MA12.5 LV MA25 LV MA50 LV MA100 LV Compact NSX160N (50 ka at 380/415 V) MA100 LV MA150 LV Compact NSX250N (50 ka at 380/415 V) MA150 LV MA220 LV With electronic trip unit Micrologic 2.2-M (LS O I motor protection) Compact NSX100N (50 ka at 380/415 V) 25 LV LV LV Compact NSX160N (50 ka at 380/415 V) 100 LV LV Compact NSX250N (50 ka at 380/415 V) 150 LV LV With electronic trip unit Micrologic 6.2 E-M (LSIG motor protection, energy meter) DB DB F-10

12 NSX100/160/250H: complete fixed/fc device Compact NSX100/160/250H (70 ka 380/415 V) DB DB DB Compact NSX100/160/250H With thermal-magnetic trip unit TM-D Compact NSX100H (70 ka at 380/415 V) 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV Compact NSX160H (70 ka at 380/415 V) 4P 3d 4P 4d TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV Compact NSX250H (70 ka at 380/415 V) 4P 3d 4P 4d TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Compact NSX100H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Compact NSX160H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV Compact NSX250H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A (LSI protection, ammeter) M d Compact NSX100H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 40 LV LV LV LV Compact NSX160H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 100 LV LV LV LV Compact NSX250H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 E (LSI protection, energy meter) With electronic trip unit Micrologic 6.2 A (LSIG protection, ammeter) With electronic trip unit Micrologic 6.2 E (LSIG protection, energy meter) F-11

13 NSX100/160/250H: complete fixed/fc device (cont.) Compact NSX100/160/250H (70 ka 380/415 V) (cont.) Compact NSX100/160/250H With magnetic trip unit MA Compact NSX100H (70 ka at 380/415 V) MA2.5 LV MA6.3 LV MA12.5 LV MA25 LV MA50 LV MA100 LV Compact NSX160H (70 ka at 380/415 V) MA100 LV MA150 LV Compact NSX250H (70 ka at 380/415 V) MA150 LV MA220 LV With electronic trip unit Micrologic 2.2-M (LS O I motor protection) Compact NSX100H (70 ka at 380/415 V) 25 LV LV LV Compact NSX160H (70 ka at 380/415 V) 100 LV LV Compact NSX250H (70 ka at 380/415 V) 150 LV LV With electronic trip unit Micrologic 6.2 E-M (LSIG motor protection, energy meter) DB DB F-12

14 NSX100/160/250NA: complete fixed/fc device Compact NSX100/160/250NA Compact NSX100/160/250NA switch-disconnector With NA switch-disconnector unit Compact NSX100NA 2P 3P 4P 100 LV LV LV Compact NSX160NA 2P 3P 4P 160 LV LV LV Compact NSX250NA 2P 3P 4P 250 LV LV LV DB F-13

15 DB Basic frame F-14 NSX100/160/250B/F/N/H/S/L: fixed/fc device based on separate components Compact and Vigicompact Compact NSX100 3P 4P NSX100B (25 ka 380/415 V) LV LV NSX100F (36 ka 380/415 V) LV LV NSX100N (50 ka 380/415 V) LV LV NSX100H (70 ka 380/415 V) LV LV NSX100S (100 ka 380/415 V) LV LV NSX100L (150 ka 380/415 V) LV LV Compact NSX160 3P 4P NSX160B (25 ka 380/415 V) LV LV NSX160F (36 ka 380/415 V) LV LV NSX160N (50 ka 380/415 V) LV LV NSX160H (70 ka 380/415 V) LV LV NSX160S (100 ka 380/415 V) LV LV NSX160L (150 ka 380/415 V) LV LV Compact NSX250 3P 4P NSX250B (25 ka 380/415 V) LV LV NSX250F (36 ka 380/415 V) LV LV NSX250N (50 ka 380/415 V) LV LV NSX250H (70 ka 380/415 V) LV LV NSX250S (100 ka 380/415 V) LV LV NSX250L (150 ka 380/415 V) LV LV Trip unit Distribution protection Thermal-magnetic TM-D 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV Micrologic 2.2 (LS O I protection) 4P 3d, 4d, 3d + N/2 Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic A LV LV Micrologic 5.2 A (LSI protection, ammeter) 4P 3d, 4d, 3d + N/2, 3d + OSN Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic 5.2 A 250 A LV LV Micrologic 5.2 E (LSI protection, energy meter) 4P 3d, 4d, 3d + N/2, 3d + OSN Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic 5.2 E 250 A LV LV Micrologic 6.2 A (LSIG protection, ammeter) 4P 3d, 4d, 3d + N/2, 3d + OSN Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic 6.2 A 250 A LV LV Micrologic 6.2 E (LSIG protection, energy meter) 4P 3d, 4d, 3d + N/2, 3d + OSN Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic 6.2 E 250 A LV LV DB DB DB Mo

16 NSX100/160/250B/F/N/H/S/L: fixed/fc device based on separate components (cont.) Compact and Vigicompact + Trip unit (cont.) Motor protection Magnetic MA (I protection) 4P 3d MA2.5 LV MA6.3 LV MA12.5 LV MA25 LV MA50 LV MA100 LV LV MA150 LV LV MA220 LV LV Micrologic 2.2-M (LS O I protection) Micrologic 2.2-M 25 LV Micrologic 2.2-M 50 A LV Micrologic 2.2-M 100 LV Micrologic 2.2-M 150 LV Micrologic 2.2-M 220 A LV Micrologic 6.2 E-M (LSIG protection, energy meter) Micrologic 6.2 E-M 25 LV Micrologic 6.2 E-M 50 LV Micrologic 6.2 E-M 80 A LV Micrologic 6.2 E-M 150 LV Micrologic 6.2 E-M 220 A LV Generator protection Thermal-magnetic TM-G 4P 4d TM16G LV LV TM25G LV LV TM40G LV LV TM63G LV LV Micrologic 2.2 G (LS O I protection) 4P 3d, 4d, 3d + N/2 Micrologic 2.2-G 40 A LV LV Micrologic 2.2-G 100 LV LV Micrologic 2.2-G 160 LV LV Micrologic 2.2-G 250 A LV LV Protection of public distribution systems Micrologic 2.2 AB (LS O I protection) 4P 3d, 4d, 3d + N/2 Micrologic 2.2-AB 100 LV Micrologic 2.2-AB 160 LV Micrologic 2.2-AB 240 A LV Hz 2/3 network protection Micrologic 5.2 A-Z (LSI protection, ammeter) Micrologic 5.2 A-Z 100 LV Micrologic 5.2 A-Z 250 A LV DB DB DB DB DB DB DB DB Vigi module or insulation monitoring module Vigi module 3P 4P ME type for NSX100/160 (200 to 440 V) LV LV MH type for NSX100/160 (200 to 440 V) LV LV MH type for NSX250 (200 to 440 V) LV LV MH type for NSX100/160 (440 to 550 V) LV LV MH type for NSX250 (440 to 550 V) LV LV Connection for a 4P Vigi on a 3P breaker LV Insulation monitoring module 3P 4P 200 to 440 V AC LV LV Connection for a 4P insulation monitoring LV module on a 3P breaker DB od Mod F-15

17 Trip unit accessories Compact and Vigicompact NSX100/160/250 Trip unit accessories External neutral CT for 3 pole breaker with Micrologic 5/ A LV DB V DC wiring accessory for Micrologic 5/ A LV V DC power supply connector LV DB ZSI wiring accessory for NS630b NW with NSX ZSI module LV DB External power supply module (24 V DC - 1 A), class DC V DC DC AC AC V AC Battery module DB V DC battery module DB A D p V p V F-16

18 Installation and connection Compact and Vigicompact NSX100/160/250 DB DB DB DB Fixed/RC device = fixed/fc device + rear connection kit Short RC kit Kit 3P Kit 4P Mixed RC kit 3 LV x LV Kit 3P Short RCs 2 LV Long RCs 1 LV Kit 4P Short RCs LV Long RCs 2 x LV Plug-in version = fixed/fc device + plug-in kit Kit for Compact Kit for Vigicompact 2P (3P) 3P 4P Plug-in kit LV LV LV Comprising: Base = 1 x LV = 1 x LV = 1 x LV Power connections + 2 x LV x LV x LV Short terminal shields + 2 x LV x LV x LV Safety trip interlock + 1 x LV x LV x LV P 4P Vigicompact plug-in kit LV LV Comprising: Base = 1 LV = 1 LV Power connections 3 LV LV Short terminal shields 2 LV LV Safety trip interlock + 1 x LV x LV Withdrawable version = fixed/fc device + withdrawable kit Kit for Compact Plug-in kit Chassis side plates for base Chassis side plates for breaker 2P (3P) 3P 4P Kit for Compact Kit for Compact Kit for Compact = = = 1 x LV x LV x LV x LV x LV x LV x LV x LV x LV DB Kit for Vigicompact Plug-in kit Chassis side plates for base Chassis side plates for breaker 3P 4P Kit for Vigicompact Kit for Vigicompact = = 1 x LV x LV x LV x LV x LV x LV F-17

19 Accessories Compact and Vigicompact NSX100/160/250 DB DB DB Connection accessories (Cu or Al) Rear connections Bare cable connectors 2 short LV long LV Steel connectors 1 x (1.5 to 95 mm2) ; y 160 A Set of 3 LV Set of 4 LV Aluminium connectors 1 x (25 to 95 mm2) ; y 250 A Set of 3 LV Set of 4 LV x (120 to 185 mm2) ; y 250 A Set of 3 LV Set of 4 LV Clips for connectors Set of 10 LV DB DB DB Aluminium connectors for 2 cables (1) 2 x (50 to 120 mm2) ; y 250 A Set of 3 LV Set of 4 LV Aluminium connectors (1) for 6 cables 6 x (1.5 to 35 mm2) ; y 250 A Set of 3 LV Set of 4 LV mm voltage tap for steel or aluminium connectors Set of 10 LV DB "Polybloc" distribution block (for bare cable) 160 (40 C) 6 cables y 10 mm2 1P A (40 C) 9 cables S y 10 mm2 3P P DB DB DB DB DB DB DB DB Terminal extensions 45 terminal extension (1) Set of 3 LV Set of 4 LV Edgewise terminal extensions (1) Set of 3 LV Set of 4 LV Right-angle terminal extensions (1) Set of 3 LV Set of 4 LV Straight terminal extensions (1) Set of 3 LV Set of 4 LV Double-L terminal extensions (1) Set of 3 LV Set of 4 LV Spreaders from 35 to 45 mm pitch (1) 3P LV P LV One-piece spreader from 35 to 45 mm pitch 3P LV P LV Front alignment base (for one-piece spreader) 3P/4P LV (1) Supplied with 2 or 3 interphase barriers. F-18

20 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) DB DB DB DB Crimp lugs for copper cable (1) Crimp lugs for aluminium cable (1) Insulation accessories For cable 120 mm2 Set of 3 LV Set of 4 LV For cable 150 mm2 Set of 3 LV Set of 4 LV For cable 185 mm2 Set of 3 LV Set of 4 LV For cable 150 mm2 Set of 3 LV Set of 4 LV For cable 185 mm2 Set of 3 LV Set of 4 LV short terminal shield for breaker or plug-in base 3 P LV P LV long terminal shield for breaker or plug-in base 3 P LV P LV Interphase barriers for breaker or plug-in base Set of 6 LV DB DB Connection adapter for plug-in base 3P LV P LV DB insulating screens for breaker (45 mm pitch) 3P LV P LV (1) Supplied with 2 or 3 interphase barriers. F-19

21 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) Electrical auxiliaries Auxiliary contacts (changeover) OF or SD or SDE or SDV OF or SD or SDE or SDV low level SDE adapter, mandatory for trip unit TM, MA or Micrologic 2 LV SDx output module for Micrologic SDx module 24/415 V AC/DC LV DB DB SDTAM contactor tripping module (early-break thermal fault signal) for Micrologic 2.2-M/6.2 E-M SDTAM 24/415 V AC/DC overload fault indication LV DB DB DB Voltage releases Voltage MX MN AC 24 50/60 Hz LV LV V 50/60 Hz LV LV /60 Hz LV LV /60 Hz and V 60 Hz LV LV V 50 Hz and V 60 Hz LV LV V 50 Hz and 600 V 60 Hz LV LV DC 12 LV LV LV LV LV LV LV LV V LV LV LV LV V LV LV MN 48 V 50/60 Hz with fixed time delay Composed of: MN 48 V DC LV Delay unit 48 V 50/60 Hz LV MN V 50/60 Hz with fixed time delay Composed of: MN 250 V DC LV Delay unit V 50/60 Hz LV MN 48 V DC/AC 50/60 Hz with adjustable time delay Composed of: MN 48 V DC LV Delay unit 48 V 50/60 Hz MN V DC/AC 50/60 Hz with adjustable time delay Composed of: MN 125 V DC LV Delay unit V 50/60 Hz MN V 50/60 Hz with adjustable time delay Composed of: MN 250 V DC LV Delay unit V 50/60 Hz F-20

22 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) Motor mechanism Motor mechanism module supplied with SDE adapter Voltage MT100/160 MT250 AC V 50/60 Hz LV LV /60 Hz LV LV /60 Hz and LV LV Hz /60 Hz and LV LV V 60 Hz DC LV LV V LV LV V LV LV V LV LV Communicating motor mechanism module supplied with SDE adapter DB DB Motor mechanism module MTc100/ /60 Hz LV MTc NSX100/ V 50/60 Hz LV MTc NSX250 + Breaker and Status BSCM LV Communication Module + NSX cord Wire length 0.35 m LV Wire length 1.3 m LV Wire length L = 3 m LV U > 480 V AC wire length L = 0.35 m LV F-21

23 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) DB Indication and measurement modules Ammeter module (A) P LV LV LV P LV LV LV I max. ammeter module (A) P LV LV LV DB Current transformer module (A) P LV LV LV P LV LV LV DB Current transformer module and voltage output (A) P LV LV LV P LV LV LV DB DB Voltage presence indicator Rotary handles Direct rotary handle DB DB Extended rotary handle 3P/4P With black handle With red handle on yellow front MCC conversion accessory CNOMO conversion accessory With black handle With red handle on yellow front With telescopic handle for withdrawable device LV LV LV LV LV LV LV LV Accessories for direct or extended rotary handle Indication auxiliary 1 early-break contact LV early-make contacts LV F-22

24 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) Locks Toggle locking device for 1 to 3 padlocks By removable device DB DB By fixed device LV Locking of rotary handle Keylock adapter (keylock not included) LV Keylock (keylock adapter not included) Ronis 1351B Profalux KS5 B24 D4Z DB Locking of motor mechanism module Keylock adapter + Ronis keylock (special) LV DB F-23

25 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) DB Interlocking Mechanical interlocking for circuit breakers With toggles LV DB With rotary handles LV DB Interlocking with key (2 keylocks / 1 key) for rotary handles Keylock kit (keylock not included) (1) 1 set of 2 keylocks (1 key only, keylock kit not included) LV Ronis 1351B Profalux KS5 B24 D4Z DB Installation accessories Front-panel escutcheons IP30 escutcheon for all control types IP30 trip unit access escutcheon for toggle IP30 escutcheon for Vigi module LV LV LV DB IP30 IP40 escutcheon for all control types IP40 escutcheon for Vigi module IP40 escutcheon for Vigi or ammeter module LV LV LV DB DB DB IP40 IP43 rubber toggle cover Lead-sealing accessories Din rail adapter 1 toggle cover LV Bag of accessories LV adapter LV mm busbar adapter 3P 60 mm busbar adapter DB (1) For only 1 device. F-24

26 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) DB DB Plug-in/withdrawable version accessories Insulation accessories Auxiliary connections 1 connection adapter for plug-in base 3P LV P LV wire fixed connector (for base) LV DB DB DB DB DB DB Plug-in base accessories 1 9-wire moving connector (for circuit breaker) LV support for 2 moving connectors LV wire manual auxiliary connector (fixed + moving) LV long insulated right angle terminal extensions Set of 2 LV IP40 shutters for base LV Base 2P LV P LV DB Base 4P LV DB DB DB DB DB DB DB DB Chassis accessories 2 power connections 2/3/4P LV short terminal shield 2/3P LV short terminal shield 4P LV safety trip interlock 2/3/4P LV Escutcheon collar Toggle LV Escutcheon collar Vigi module LV Locking kit (keylock not included) LV Keylock (keylock adapter not included) Ronis 1351B Profalux KS5 B24 D4Z carriage switches (connected/disconnected position indication) LV F-25

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Wiring diagrams. Compact NSX. Contents

Wiring diagrams. Compact NSX. Contents Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011

Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011 Low Voltage EasyPact CVS Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A Catalogue 2011 Safe Reliable Simple The easy choice for quality and value EasyPact CVS LV circuit breakers

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

Compact, Interpact and Masterpact. Source changeover system. Catalogue 2007

Compact, Interpact and Masterpact. Source changeover system. Catalogue 2007 Compact, Interpact and Masterpact Source changeover system Catalogue 2007 PB100839 To ensure a continuous supply of electrical power, certain installations are connected to two sources: a normal source

More information

General information Circuit breakers for power distribution T1 T3

General information Circuit breakers for power distribution T1 T3 Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480

More information

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit? Data Bulletin 011DB110 07/01 Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers ENGLISH Inoduction Thermal-Magnetic or Eleconic Trip Unit? Thermal-Magnetic Trip Units 01171 t 0119

More information

more than a breaker it s a breakthrough Compact NSX

more than a breaker it s a breakthrough Compact NSX Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,

More information

Catalogue. Merlin Gerin Compact LV circuit breakers and switch-disconnectors 80 to 3200A

Catalogue. Merlin Gerin Compact LV circuit breakers and switch-disconnectors 80 to 3200A Catalogue 01 Merlin Gerin Compact LV circuit breakers and switch-disconnectors 80 to 300A Compact NS 80 A Compact NS 100 to 50 A Things will never be the same Compact NS 400 to 630 A New Compact NS, setting

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120 Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker

More information

Spare parts Catalogue

Spare parts Catalogue Technical catalogue Spare parts Catalogue Low voltage circuit-breakers Product support ABB SACE SDC0000D00 Not every original spare parts are really original spare parts. Availability of spare parts for

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

QUICK REFERENCE PRICE GUIDE JULY 2015

QUICK REFERENCE PRICE GUIDE JULY 2015 QUICK REFERENCE PRICE GUIDE JULY 2015 ISO 9001: 2008 OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this Quick Price Guide carry a guarantee against defects in materials

More information

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors IZM ACB/Circuit-breakers Robust safety Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors t [s] 0.1 0.05 0.04 0.03 0.02 0.01 20 1230DIA-125 (70C1043) 30 40 50 60 80 100

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Low voltage electrical distribution. Electronic trip units. User manual 09/2009

Low voltage electrical distribution. Electronic trip units. User manual 09/2009 Low voltage electrical distribution Electronic trip units User manual 09/2009 Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for

More information

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager SACE Emax 2 From Circuit-Breaker to Power Manager Our customers need more efficient solutions, to Increase

More information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination

More information

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution Low voltage circuit breakers Susol LV circuit breakers Super Solution Contents Overview Electrical characteristics Trip units Accessories

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Breaking and protection devices

Breaking and protection devices Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Motor circuit-breakers

Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Molded case circuit breakers

Molded case circuit breakers Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high

More information

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145 KNX system units The system components are KNX devices, which assume higher-level functions, independent of the application. They guarantee the necessary infrastructure in the building, ensuring a flawless

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

GE Power Controls. MiniFORM Switchboards

GE Power Controls. MiniFORM Switchboards GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules

More information

Low Voltage Products. Switches Automatic Transfer Switches

Low Voltage Products. Switches Automatic Transfer Switches Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,

More information

Functional system Prisma P

Functional system Prisma P Enclosures and cubicles Functional system Prisma P Catalogue Prisma functional system Contents general page Index 2 Choice of switchboards 6 Prisma P functional system 11 b General presentation 12 b Installation

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

VL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers

VL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers VL circuit breakers Information guide www.usa.siemens.com/circuitbreakers Table of contents Technical data 2 8 DG 150A frame 9 14 FG 250A frame 15 20 JG 400A frame 21 26 LG 600A frame 27 32 MG 800A frame

More information

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents

More information

Catalog. Arc Guard System TM TVOC-2

Catalog. Arc Guard System TM TVOC-2 Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated

Technical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated Technical catalogue - Ordering Codes SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated New SACE Tmax XT. Simply XTraordinary. Today a highly advanced range of circuit-breakers

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases. G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Power Generation. Power Control PCL System Generator Set Control

Power Generation. Power Control PCL System Generator Set Control Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

White Paper - July 2012. ATS021-ATS022 Automatic transfer switching

White Paper - July 2012. ATS021-ATS022 Automatic transfer switching White Paper - July 202 02-022 Automatic transfer switching 02-022 Automatic transfer switching Index. Introduction...2 2. Description of... Switching logics...6 Transformer for the main and generator

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000 Seite 1 von 6 Certification Record CUSTOMER CLASS FILE ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000 Eppelheimer Strasse 82, SUPPLEMENTARY PROTECTORS- COMPONENT ACCEPTANCE PROGRAM Heidelberg Baden-Wurttemberg

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

30 minutes to perform a retrofit of your Masterpact M

30 minutes to perform a retrofit of your Masterpact M 30 minutes to perform a retrofit of your Masterpact M "Plug and Play" retrofit solution 2009 Fast and easy implementation Continuity of service guaranteed Certified "Plug and Play" solution "Plug and Play"

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers

Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers Get more with the world s Power & Control specialist Protection Merlin Gerin Multi 9 System Miniature circuit breakers Tripping curves

More information

THE ADVANTAGES ARE YOURS

THE ADVANTAGES ARE YOURS THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many

More information

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

NM8, NM8S NM8, NM8S. Moulded Case Circuit Breakers. 3. Type designation. 4. Product overview N M 8 / / /

NM8, NM8S NM8, NM8S. Moulded Case Circuit Breakers. 3. Type designation. 4. Product overview N M 8 / / / Moulded Case Circuit Breakers NM8, NM8S 3. Type designation 4. Product overview N M 8 / / / NM8 Moulded Case Circuit Breaker Application code Blank: for power distribution; NM8, NM8S Moulded Case Circuit

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity

More information

Circuit Breaker. Description

Circuit Breaker. Description Data Bulletin 0739DB9901R11/03 Cedar Rapids, Iowa, USA International Miniature Circuit Breakers with QO Plug-on and Bolt-on Connections Class Number 0739 Retain for future use. GENERAL DESCRIPTION The

More information

Contact expansion modules

Contact expansion modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical

More information

Mureva Assembly surface mounted wiring devices

Mureva Assembly surface mounted wiring devices 1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager 2 1SDC200039B0201 New SACE Emax 2 for UL 1066 Circuit breakers switch power SACE Emax 2 manages it. SACE Emax 2 is the new benchmark of

More information

Index. 17 - Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers...17.67-17.70

Index. 17 - Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers...17.67-17.70 Molded case circuit breakers Index Molded case circuit breakers - Molded case circuit breakers Formula...1 -.10 General information Introduction...1 Circuit breakers for power distribution...2 explanation...3

More information

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS Definition: Zone Selective Interlocking (ZSI) - A method which allows two or more ground fault breakers to communicate with each other so that a short circuit or ground fault will be cleared by the breaker

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information