Simplicity of catalogue numbers
|
|
- Beverly Griffith
- 7 years ago
- Views:
Transcription
1 Simplicity of catalogue numbers
2 Compact NSX Catalogue numbers Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection C-1 Wiring diagrams D-1 Additional characteristics E-1 NSX100 to 250 F-3 NSX400 to 630 F-29 Glossary G-1 F-1
3 F-2
4 Compact NSX Compact NSX100 to 250 Contents NSX100/160/250B: complete fixed/fc device Compact NSX100/160/250B (25 ka 380/415 V) F-4 Vigicompact NSX100/160/250B (25 ka 380/415 V) F-5 NSX100/160/250F: complete fixed/fc device Compact NSX100/160/250F (36 ka 380/415 V) F-6 Vigicompact NSX100/160/250F (36 ka 380/415 V) F-8 NSX100/160/250N: complete fixed/fc device Compact NSX100/160/250N (50 ka 380/415 V) F-9 NSX100/160/250H: complete fixed/fc device Compact NSX100/160/250H (70 ka 380/415 V) F-11 NSX100/160/250NA: complete fixed/fc device Compact NSX100/160/250NA F-13 NSX100/160/250B/F/N/H/S/L: fixed/fc device based on separate components Compact and Vigicompact F-14 Trip unit accessories Compact and Vigicompact NSX100/160/250 F-16 Installation and connection Compact and Vigicompact NSX100/160/250 F-17 Accessories Compact and Vigicompact NSX100/160/250 F-18 Monitoring and control, test tools Compact and Vigicompact NSX100/160/250 F-27 F-3
5 NSX100/160/250B: complete fixed/fc device Compact NSX100/160/250B (25 ka 380/415 V) DB DB DB Compact NSX100/160/250B With thermal-magnetic trip unit TM-D Compact NSX100B (25 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM16D LV LV LV LV TM25D LV LV LV LV TM32D LV LV LV LV TM40D LV LV LV LV TM50D LV LV LV LV TM63D LV LV LV LV TM80D LV LV LV LV TM100D LV LV LV LV Compact NSX160B (25 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM80D LV LV LV LV TM100D LV LV LV LV TM125D LV LV LV LV TM160D LV LV LV LV Compact NSX250B (25 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM125D LV LV LV LV TM160D LV LV LV LV TM200D LV LV LV LV TM250D LV LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Compact NSX100B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Compact NSX160B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV Compact NSX250B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A (LSI protection, ammeter) od Compact NSX100B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 40 LV LV LV LV Compact NSX160B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 100 LV LV LV LV Compact NSX250B (25 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 E (LSI protection, energy meter) With electronic trip unit Micrologic 6.2 A (LSIG protection, ammeter) With electronic trip unit Micrologic 6.2 E (LSIG protection, energy meter) F-4
6 NSX100/160/250B: complete fixed/fc device Vigicompact (25 ka 380/415 NSX100/160/250B V) DB Vigicompact NSX100/160/250B With thermal-magnetic trip unit TM-D Vigicompact NSX100B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV Vigicompact NSX160B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV Vigicompact NSX250B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Vigicompact NSX100B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Vigicompact NSX160B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV LV LV Vigicompact NSX250B (25 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A or 5.2 E (LSI protection, ammeter or energy meter) DB F-5
7 NSX100/160/250F: complete fixed/fc device Compact NSX100/160/250F (36 ka 380/415 V) DB DB DB Compact NSX100/160/250F With thermal-magnetic trip unit TM-D Compact NSX100F (36 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM16D LV LV LV LV TM25D LV LV LV LV TM32D LV LV LV LV TM40D LV LV LV LV TM50D LV LV LV LV TM63D LV LV LV LV TM80D LV LV LV LV TM100D LV LV LV LV Compact NSX160F (36 ka at 380/415 V) 3P 2d 4P 3d 4P 4d TM80D LV LV LV LV TM100D LV LV LV LV TM125D LV LV LV LV TM160D LV LV LV LV Compact NSX250F (36 ka at 380/415 V) 4P 3d 4P 4d TM125D LV LV LV LV TM160D LV LV LV LV TM200D LV LV LV LV TM250D LV LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Compact NSX100F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Compact NSX160F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV Compact NSX250F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A (LSI protection, ammeter) od Compact NSX100F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 40 LV LV LV LV Compact NSX160F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 100 LV LV LV LV Compact NSX250F (36 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, 3d + OSN 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 E (LSI protection, energy meter) With electronic trip unit Micrologic 6.2 A (LSIG protection, ammeter) With electronic trip unit Micrologic 6.2 E (LSIG protection, energy meter) F-6
8 NSX100/160/250F: complete fixed/fc device (cont.) Compact NSX100/160/250F (36 ka 380/415 V) (cont.) Compact NSX100/160/250F With magnetic trip unit MA Compact NSX100F (36 ka at 380/415 V) MA2.5 LV MA6.3 LV MA12.5 LV MA25 LV MA50 LV MA100 LV Compact NSX160F (36 ka at 380/415 V) MA100 LV MA150 LV Compact NSX250F (36 ka at 380/415 V) MA150 LV MA220 LV With electronic trip unit Micrologic 2.2-M (LS O I motor protection) Compact NSX100F (36 ka at 380/415 V) 25 LV LV LV Compact NSX160F (36 ka at 380/415 V) 100 LV LV Compact NSX250F (36 ka at 380/415 V) 150 LV LV With electronic trip unit Micrologic 6.2 E-M (LSIG motor protection, energy meter) DB DB F-7
9 NSX100/160/250F: complete fixed/fc device Vigicompact (36 ka 380/415 NSX100/160/250F V) DB Vigicompact NSX100/160/250F With thermal-magnetic trip unit TM-D Vigicompact NSX100F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV Vigicompact NSX160F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV Vigicompact NSX250F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d 4P 4d TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Vigicompact NSX100F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Vigicompact NSX160F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV LV LV Vigicompact NSX250F (36 ka at 380/415 V) equipped with MH Vigi module (200 to 440 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A or 5.2 E (LSI protection, energy meter) DB F-8
10 NSX100/160/250N: complete fixed/fc device Compact NSX100/160/250N (50 ka 380/415 V) DB DB DB Compact NSX100/160/250N With thermal-magnetic trip unit TM-D Compact NSX100N (50 ka at 380/415 V) 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV Compact NSX160N (50 ka at 380/415 V) 4P 3d 4P 4d TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV Compact NSX250N (50 ka at 380/415 V) 4P 3d 4P 4d TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Compact NSX100N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Compact NSX160N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV Compact NSX250N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A (LSI protection, ammeter) M d Compact NSX100N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 40 LV LV LV LV Compact NSX160N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 100 LV LV LV LV Compact NSX250N (50 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 E (LSI protection, energy meter) With electronic trip unit Micrologic 6.2 A (LSIG protection, ammeter) With electronic trip unit Micrologic 6.2 E (LSIG protection, energy meter) F-9
11 NSX100/160/250N: complete fixed/fc device (cont.) Compact NSX100/160/250N (50 ka 380/415 V) (cont.) Compact NSX100/160/250N With magnetic trip unit MA Compact NSX100N (50 ka at 380/415 V) MA2.5 LV MA6.3 LV MA12.5 LV MA25 LV MA50 LV MA100 LV Compact NSX160N (50 ka at 380/415 V) MA100 LV MA150 LV Compact NSX250N (50 ka at 380/415 V) MA150 LV MA220 LV With electronic trip unit Micrologic 2.2-M (LS O I motor protection) Compact NSX100N (50 ka at 380/415 V) 25 LV LV LV Compact NSX160N (50 ka at 380/415 V) 100 LV LV Compact NSX250N (50 ka at 380/415 V) 150 LV LV With electronic trip unit Micrologic 6.2 E-M (LSIG motor protection, energy meter) DB DB F-10
12 NSX100/160/250H: complete fixed/fc device Compact NSX100/160/250H (70 ka 380/415 V) DB DB DB Compact NSX100/160/250H With thermal-magnetic trip unit TM-D Compact NSX100H (70 ka at 380/415 V) 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV Compact NSX160H (70 ka at 380/415 V) 4P 3d 4P 4d TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV Compact NSX250H (70 ka at 380/415 V) 4P 3d 4P 4d TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV With electronic trip unit Micrologic 2.2 (LS O I protection) Compact NSX100H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 40 LV LV LV LV Compact NSX160H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV Compact NSX250H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 A (LSI protection, ammeter) M d Compact NSX100H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 40 LV LV LV LV Compact NSX160H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 100 LV LV LV LV Compact NSX250H (70 ka at 380/415 V) 4P 3d, 4d, 3d + N/2, OSN 100 LV LV LV LV LV LV With electronic trip unit Micrologic 5.2 E (LSI protection, energy meter) With electronic trip unit Micrologic 6.2 A (LSIG protection, ammeter) With electronic trip unit Micrologic 6.2 E (LSIG protection, energy meter) F-11
13 NSX100/160/250H: complete fixed/fc device (cont.) Compact NSX100/160/250H (70 ka 380/415 V) (cont.) Compact NSX100/160/250H With magnetic trip unit MA Compact NSX100H (70 ka at 380/415 V) MA2.5 LV MA6.3 LV MA12.5 LV MA25 LV MA50 LV MA100 LV Compact NSX160H (70 ka at 380/415 V) MA100 LV MA150 LV Compact NSX250H (70 ka at 380/415 V) MA150 LV MA220 LV With electronic trip unit Micrologic 2.2-M (LS O I motor protection) Compact NSX100H (70 ka at 380/415 V) 25 LV LV LV Compact NSX160H (70 ka at 380/415 V) 100 LV LV Compact NSX250H (70 ka at 380/415 V) 150 LV LV With electronic trip unit Micrologic 6.2 E-M (LSIG motor protection, energy meter) DB DB F-12
14 NSX100/160/250NA: complete fixed/fc device Compact NSX100/160/250NA Compact NSX100/160/250NA switch-disconnector With NA switch-disconnector unit Compact NSX100NA 2P 3P 4P 100 LV LV LV Compact NSX160NA 2P 3P 4P 160 LV LV LV Compact NSX250NA 2P 3P 4P 250 LV LV LV DB F-13
15 DB Basic frame F-14 NSX100/160/250B/F/N/H/S/L: fixed/fc device based on separate components Compact and Vigicompact Compact NSX100 3P 4P NSX100B (25 ka 380/415 V) LV LV NSX100F (36 ka 380/415 V) LV LV NSX100N (50 ka 380/415 V) LV LV NSX100H (70 ka 380/415 V) LV LV NSX100S (100 ka 380/415 V) LV LV NSX100L (150 ka 380/415 V) LV LV Compact NSX160 3P 4P NSX160B (25 ka 380/415 V) LV LV NSX160F (36 ka 380/415 V) LV LV NSX160N (50 ka 380/415 V) LV LV NSX160H (70 ka 380/415 V) LV LV NSX160S (100 ka 380/415 V) LV LV NSX160L (150 ka 380/415 V) LV LV Compact NSX250 3P 4P NSX250B (25 ka 380/415 V) LV LV NSX250F (36 ka 380/415 V) LV LV NSX250N (50 ka 380/415 V) LV LV NSX250H (70 ka 380/415 V) LV LV NSX250S (100 ka 380/415 V) LV LV NSX250L (150 ka 380/415 V) LV LV Trip unit Distribution protection Thermal-magnetic TM-D 4P 3d 4P 4d TM16D LV LV LV TM25D LV LV LV TM32D LV LV LV TM40D LV LV LV TM50D LV LV LV TM63D LV LV LV TM80D LV LV LV TM100D LV LV LV TM125D LV LV LV TM160D LV LV LV TM200D LV LV LV TM250D LV LV LV Micrologic 2.2 (LS O I protection) 4P 3d, 4d, 3d + N/2 Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic A LV LV Micrologic 5.2 A (LSI protection, ammeter) 4P 3d, 4d, 3d + N/2, 3d + OSN Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic 5.2 A 250 A LV LV Micrologic 5.2 E (LSI protection, energy meter) 4P 3d, 4d, 3d + N/2, 3d + OSN Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic 5.2 E 250 A LV LV Micrologic 6.2 A (LSIG protection, ammeter) 4P 3d, 4d, 3d + N/2, 3d + OSN Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic 6.2 A 250 A LV LV Micrologic 6.2 E (LSIG protection, energy meter) 4P 3d, 4d, 3d + N/2, 3d + OSN Micrologic A LV LV Micrologic LV LV Micrologic LV LV Micrologic 6.2 E 250 A LV LV DB DB DB Mo
16 NSX100/160/250B/F/N/H/S/L: fixed/fc device based on separate components (cont.) Compact and Vigicompact + Trip unit (cont.) Motor protection Magnetic MA (I protection) 4P 3d MA2.5 LV MA6.3 LV MA12.5 LV MA25 LV MA50 LV MA100 LV LV MA150 LV LV MA220 LV LV Micrologic 2.2-M (LS O I protection) Micrologic 2.2-M 25 LV Micrologic 2.2-M 50 A LV Micrologic 2.2-M 100 LV Micrologic 2.2-M 150 LV Micrologic 2.2-M 220 A LV Micrologic 6.2 E-M (LSIG protection, energy meter) Micrologic 6.2 E-M 25 LV Micrologic 6.2 E-M 50 LV Micrologic 6.2 E-M 80 A LV Micrologic 6.2 E-M 150 LV Micrologic 6.2 E-M 220 A LV Generator protection Thermal-magnetic TM-G 4P 4d TM16G LV LV TM25G LV LV TM40G LV LV TM63G LV LV Micrologic 2.2 G (LS O I protection) 4P 3d, 4d, 3d + N/2 Micrologic 2.2-G 40 A LV LV Micrologic 2.2-G 100 LV LV Micrologic 2.2-G 160 LV LV Micrologic 2.2-G 250 A LV LV Protection of public distribution systems Micrologic 2.2 AB (LS O I protection) 4P 3d, 4d, 3d + N/2 Micrologic 2.2-AB 100 LV Micrologic 2.2-AB 160 LV Micrologic 2.2-AB 240 A LV Hz 2/3 network protection Micrologic 5.2 A-Z (LSI protection, ammeter) Micrologic 5.2 A-Z 100 LV Micrologic 5.2 A-Z 250 A LV DB DB DB DB DB DB DB DB Vigi module or insulation monitoring module Vigi module 3P 4P ME type for NSX100/160 (200 to 440 V) LV LV MH type for NSX100/160 (200 to 440 V) LV LV MH type for NSX250 (200 to 440 V) LV LV MH type for NSX100/160 (440 to 550 V) LV LV MH type for NSX250 (440 to 550 V) LV LV Connection for a 4P Vigi on a 3P breaker LV Insulation monitoring module 3P 4P 200 to 440 V AC LV LV Connection for a 4P insulation monitoring LV module on a 3P breaker DB od Mod F-15
17 Trip unit accessories Compact and Vigicompact NSX100/160/250 Trip unit accessories External neutral CT for 3 pole breaker with Micrologic 5/ A LV DB V DC wiring accessory for Micrologic 5/ A LV V DC power supply connector LV DB ZSI wiring accessory for NS630b NW with NSX ZSI module LV DB External power supply module (24 V DC - 1 A), class DC V DC DC AC AC V AC Battery module DB V DC battery module DB A D p V p V F-16
18 Installation and connection Compact and Vigicompact NSX100/160/250 DB DB DB DB Fixed/RC device = fixed/fc device + rear connection kit Short RC kit Kit 3P Kit 4P Mixed RC kit 3 LV x LV Kit 3P Short RCs 2 LV Long RCs 1 LV Kit 4P Short RCs LV Long RCs 2 x LV Plug-in version = fixed/fc device + plug-in kit Kit for Compact Kit for Vigicompact 2P (3P) 3P 4P Plug-in kit LV LV LV Comprising: Base = 1 x LV = 1 x LV = 1 x LV Power connections + 2 x LV x LV x LV Short terminal shields + 2 x LV x LV x LV Safety trip interlock + 1 x LV x LV x LV P 4P Vigicompact plug-in kit LV LV Comprising: Base = 1 LV = 1 LV Power connections 3 LV LV Short terminal shields 2 LV LV Safety trip interlock + 1 x LV x LV Withdrawable version = fixed/fc device + withdrawable kit Kit for Compact Plug-in kit Chassis side plates for base Chassis side plates for breaker 2P (3P) 3P 4P Kit for Compact Kit for Compact Kit for Compact = = = 1 x LV x LV x LV x LV x LV x LV x LV x LV x LV DB Kit for Vigicompact Plug-in kit Chassis side plates for base Chassis side plates for breaker 3P 4P Kit for Vigicompact Kit for Vigicompact = = 1 x LV x LV x LV x LV x LV x LV F-17
19 Accessories Compact and Vigicompact NSX100/160/250 DB DB DB Connection accessories (Cu or Al) Rear connections Bare cable connectors 2 short LV long LV Steel connectors 1 x (1.5 to 95 mm2) ; y 160 A Set of 3 LV Set of 4 LV Aluminium connectors 1 x (25 to 95 mm2) ; y 250 A Set of 3 LV Set of 4 LV x (120 to 185 mm2) ; y 250 A Set of 3 LV Set of 4 LV Clips for connectors Set of 10 LV DB DB DB Aluminium connectors for 2 cables (1) 2 x (50 to 120 mm2) ; y 250 A Set of 3 LV Set of 4 LV Aluminium connectors (1) for 6 cables 6 x (1.5 to 35 mm2) ; y 250 A Set of 3 LV Set of 4 LV mm voltage tap for steel or aluminium connectors Set of 10 LV DB "Polybloc" distribution block (for bare cable) 160 (40 C) 6 cables y 10 mm2 1P A (40 C) 9 cables S y 10 mm2 3P P DB DB DB DB DB DB DB DB Terminal extensions 45 terminal extension (1) Set of 3 LV Set of 4 LV Edgewise terminal extensions (1) Set of 3 LV Set of 4 LV Right-angle terminal extensions (1) Set of 3 LV Set of 4 LV Straight terminal extensions (1) Set of 3 LV Set of 4 LV Double-L terminal extensions (1) Set of 3 LV Set of 4 LV Spreaders from 35 to 45 mm pitch (1) 3P LV P LV One-piece spreader from 35 to 45 mm pitch 3P LV P LV Front alignment base (for one-piece spreader) 3P/4P LV (1) Supplied with 2 or 3 interphase barriers. F-18
20 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) DB DB DB DB Crimp lugs for copper cable (1) Crimp lugs for aluminium cable (1) Insulation accessories For cable 120 mm2 Set of 3 LV Set of 4 LV For cable 150 mm2 Set of 3 LV Set of 4 LV For cable 185 mm2 Set of 3 LV Set of 4 LV For cable 150 mm2 Set of 3 LV Set of 4 LV For cable 185 mm2 Set of 3 LV Set of 4 LV short terminal shield for breaker or plug-in base 3 P LV P LV long terminal shield for breaker or plug-in base 3 P LV P LV Interphase barriers for breaker or plug-in base Set of 6 LV DB DB Connection adapter for plug-in base 3P LV P LV DB insulating screens for breaker (45 mm pitch) 3P LV P LV (1) Supplied with 2 or 3 interphase barriers. F-19
21 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) Electrical auxiliaries Auxiliary contacts (changeover) OF or SD or SDE or SDV OF or SD or SDE or SDV low level SDE adapter, mandatory for trip unit TM, MA or Micrologic 2 LV SDx output module for Micrologic SDx module 24/415 V AC/DC LV DB DB SDTAM contactor tripping module (early-break thermal fault signal) for Micrologic 2.2-M/6.2 E-M SDTAM 24/415 V AC/DC overload fault indication LV DB DB DB Voltage releases Voltage MX MN AC 24 50/60 Hz LV LV V 50/60 Hz LV LV /60 Hz LV LV /60 Hz and V 60 Hz LV LV V 50 Hz and V 60 Hz LV LV V 50 Hz and 600 V 60 Hz LV LV DC 12 LV LV LV LV LV LV LV LV V LV LV LV LV V LV LV MN 48 V 50/60 Hz with fixed time delay Composed of: MN 48 V DC LV Delay unit 48 V 50/60 Hz LV MN V 50/60 Hz with fixed time delay Composed of: MN 250 V DC LV Delay unit V 50/60 Hz LV MN 48 V DC/AC 50/60 Hz with adjustable time delay Composed of: MN 48 V DC LV Delay unit 48 V 50/60 Hz MN V DC/AC 50/60 Hz with adjustable time delay Composed of: MN 125 V DC LV Delay unit V 50/60 Hz MN V 50/60 Hz with adjustable time delay Composed of: MN 250 V DC LV Delay unit V 50/60 Hz F-20
22 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) Motor mechanism Motor mechanism module supplied with SDE adapter Voltage MT100/160 MT250 AC V 50/60 Hz LV LV /60 Hz LV LV /60 Hz and LV LV Hz /60 Hz and LV LV V 60 Hz DC LV LV V LV LV V LV LV V LV LV Communicating motor mechanism module supplied with SDE adapter DB DB Motor mechanism module MTc100/ /60 Hz LV MTc NSX100/ V 50/60 Hz LV MTc NSX250 + Breaker and Status BSCM LV Communication Module + NSX cord Wire length 0.35 m LV Wire length 1.3 m LV Wire length L = 3 m LV U > 480 V AC wire length L = 0.35 m LV F-21
23 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) DB Indication and measurement modules Ammeter module (A) P LV LV LV P LV LV LV I max. ammeter module (A) P LV LV LV DB Current transformer module (A) P LV LV LV P LV LV LV DB Current transformer module and voltage output (A) P LV LV LV P LV LV LV DB DB Voltage presence indicator Rotary handles Direct rotary handle DB DB Extended rotary handle 3P/4P With black handle With red handle on yellow front MCC conversion accessory CNOMO conversion accessory With black handle With red handle on yellow front With telescopic handle for withdrawable device LV LV LV LV LV LV LV LV Accessories for direct or extended rotary handle Indication auxiliary 1 early-break contact LV early-make contacts LV F-22
24 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) Locks Toggle locking device for 1 to 3 padlocks By removable device DB DB By fixed device LV Locking of rotary handle Keylock adapter (keylock not included) LV Keylock (keylock adapter not included) Ronis 1351B Profalux KS5 B24 D4Z DB Locking of motor mechanism module Keylock adapter + Ronis keylock (special) LV DB F-23
25 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) DB Interlocking Mechanical interlocking for circuit breakers With toggles LV DB With rotary handles LV DB Interlocking with key (2 keylocks / 1 key) for rotary handles Keylock kit (keylock not included) (1) 1 set of 2 keylocks (1 key only, keylock kit not included) LV Ronis 1351B Profalux KS5 B24 D4Z DB Installation accessories Front-panel escutcheons IP30 escutcheon for all control types IP30 trip unit access escutcheon for toggle IP30 escutcheon for Vigi module LV LV LV DB IP30 IP40 escutcheon for all control types IP40 escutcheon for Vigi module IP40 escutcheon for Vigi or ammeter module LV LV LV DB DB DB IP40 IP43 rubber toggle cover Lead-sealing accessories Din rail adapter 1 toggle cover LV Bag of accessories LV adapter LV mm busbar adapter 3P 60 mm busbar adapter DB (1) For only 1 device. F-24
26 Accessories (cont.) Compact and Vigicompact NSX100/160/250 (cont.) DB DB Plug-in/withdrawable version accessories Insulation accessories Auxiliary connections 1 connection adapter for plug-in base 3P LV P LV wire fixed connector (for base) LV DB DB DB DB DB DB Plug-in base accessories 1 9-wire moving connector (for circuit breaker) LV support for 2 moving connectors LV wire manual auxiliary connector (fixed + moving) LV long insulated right angle terminal extensions Set of 2 LV IP40 shutters for base LV Base 2P LV P LV DB Base 4P LV DB DB DB DB DB DB DB DB Chassis accessories 2 power connections 2/3/4P LV short terminal shield 2/3P LV short terminal shield 4P LV safety trip interlock 2/3/4P LV Escutcheon collar Toggle LV Escutcheon collar Vigi module LV Locking kit (keylock not included) LV Keylock (keylock adapter not included) Ronis 1351B Profalux KS5 B24 D4Z carriage switches (connected/disconnected position indication) LV F-25
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationWiring diagrams. Compact NSX. Contents
Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable
More informationLow Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011
Low Voltage EasyPact CVS Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A Catalogue 2011 Safe Reliable Simple The easy choice for quality and value EasyPact CVS LV circuit breakers
More informationMasterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A
Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact
More informationCompact, Interpact and Masterpact. Source changeover system. Catalogue 2007
Compact, Interpact and Masterpact Source changeover system Catalogue 2007 PB100839 To ensure a continuous supply of electrical power, certain installations are connected to two sources: a normal source
More informationGeneral information Circuit breakers for power distribution T1 T3
Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480
More informationData Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?
Data Bulletin 011DB110 07/01 Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers ENGLISH Inoduction Thermal-Magnetic or Eleconic Trip Unit? Thermal-Magnetic Trip Units 01171 t 0119
More informationmore than a breaker it s a breakthrough Compact NSX
Compact NSX, more than a breaker it s a breakthrough Compact NSX 100-630 A Intelligent outlook Today, we are living in an increasingly booming and fast changing world where energy is key. More than ever,
More informationCatalogue. Merlin Gerin Compact LV circuit breakers and switch-disconnectors 80 to 3200A
Catalogue 01 Merlin Gerin Compact LV circuit breakers and switch-disconnectors 80 to 300A Compact NS 80 A Compact NS 100 to 50 A Things will never be the same Compact NS 400 to 630 A New Compact NS, setting
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationElectrical auxiliaries 0 For i DPN (DPN), C60 and C120
Circuit protection For i DPN (DPN), C60 and C120 Function They remotely trip or indicate circuit-breakers, with or without Vigi module. Description b They are mounted to the left of the circuit-breaker
More informationSpare parts Catalogue
Technical catalogue Spare parts Catalogue Low voltage circuit-breakers Product support ABB SACE SDC0000D00 Not every original spare parts are really original spare parts. Availability of spare parts for
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationQUICK REFERENCE PRICE GUIDE JULY 2015
QUICK REFERENCE PRICE GUIDE JULY 2015 ISO 9001: 2008 OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this Quick Price Guide carry a guarantee against defects in materials
More informationIZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors
IZM ACB/Circuit-breakers Robust safety Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors t [s] 0.1 0.05 0.04 0.03 0.02 0.01 20 1230DIA-125 (70C1043) 30 40 50 60 80 100
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationLow voltage electrical distribution. Electronic trip units. User manual 09/2009
Low voltage electrical distribution Electronic trip units User manual 09/2009 Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for
More informationFranco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager
Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager SACE Emax 2 From Circuit-Breaker to Power Manager Our customers need more efficient solutions, to Increase
More informationCam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5
Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More informationCircuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
More informationNEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution
NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution Low voltage circuit breakers Susol LV circuit breakers Super Solution Contents Overview Electrical characteristics Trip units Accessories
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationBreaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
More informationAUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationMotor circuit-breakers
Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationMolded case circuit breakers
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationPower supply 142. Couplers 143. Data interfaces 144. Accessories 145
KNX system units The system components are KNX devices, which assume higher-level functions, independent of the application. They guarantee the necessary infrastructure in the building, ensuring a flawless
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
More informationMolded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
More informationLV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. << Back. Catalogue
More information
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationGE Power Controls. MiniFORM Switchboards
GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules
More informationLow Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
More informationFunctional system Prisma P
Enclosures and cubicles Functional system Prisma P Catalogue Prisma functional system Contents general page Index 2 Choice of switchboards 6 Prisma P functional system 11 b General presentation 12 b Installation
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationCurrent and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationVL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers
VL circuit breakers Information guide www.usa.siemens.com/circuitbreakers Table of contents Technical data 2 8 DG 150A frame 9 14 FG 250A frame 15 20 JG 400A frame 21 26 LG 600A frame 27 32 MG 800A frame
More informationElectronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents
More informationCatalog. Arc Guard System TM TVOC-2
Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More information3K Load-Break Switches The Program for Safety and Performance. sentric
3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break
More informationTechnical catalogue - Ordering Codes. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated
Technical catalogue - Ordering Codes SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A 50 C rated New SACE Tmax XT. Simply XTraordinary. Today a highly advanced range of circuit-breakers
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationRenewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.
G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable
More informationDimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
More informationPhotovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
More informationPower Generation. Power Control PCL System Generator Set Control
Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationWhite Paper - July 2012. ATS021-ATS022 Automatic transfer switching
White Paper - July 202 02-022 Automatic transfer switching 02-022 Automatic transfer switching Index. Introduction...2 2. Description of... Switching logics...6 Transformer for the main and generator
More informationSECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
More informationCUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000
Seite 1 von 6 Certification Record CUSTOMER CLASS FILE ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000 Eppelheimer Strasse 82, SUPPLEMENTARY PROTECTORS- COMPONENT ACCEPTANCE PROGRAM Heidelberg Baden-Wurttemberg
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationData Sheet. Electro-mechanical counters Hengstler 800 series
Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More information30 minutes to perform a retrofit of your Masterpact M
30 minutes to perform a retrofit of your Masterpact M "Plug and Play" retrofit solution 2009 Fast and easy implementation Continuity of service guaranteed Certified "Plug and Play" solution "Plug and Play"
More informationDigital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationMerlin Gerin Multi 9 System Protection Miniature Circuit Breakers
Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers Get more with the world s Power & Control specialist Protection Merlin Gerin Multi 9 System Miniature circuit breakers Tripping curves
More informationTHE ADVANTAGES ARE YOURS
THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many
More informationW DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationNM8, NM8S NM8, NM8S. Moulded Case Circuit Breakers. 3. Type designation. 4. Product overview N M 8 / / /
Moulded Case Circuit Breakers NM8, NM8S 3. Type designation 4. Product overview N M 8 / / / NM8 Moulded Case Circuit Breaker Application code Blank: for power distribution; NM8, NM8S Moulded Case Circuit
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationINSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
More informationNIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
More informationCircuit Breaker. Description
Data Bulletin 0739DB9901R11/03 Cedar Rapids, Iowa, USA International Miniature Circuit Breakers with QO Plug-on and Bolt-on Connections Class Number 0739 Retain for future use. GENERAL DESCRIPTION The
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationMETAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationFIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
More informationUniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
More informationISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
More informationMureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
More informationE-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationNew SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager
New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager 2 1SDC200039B0201 New SACE Emax 2 for UL 1066 Circuit breakers switch power SACE Emax 2 manages it. SACE Emax 2 is the new benchmark of
More informationIndex. 17 - Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers...17.67-17.70
Molded case circuit breakers Index Molded case circuit breakers - Molded case circuit breakers Formula...1 -.10 General information Introduction...1 Circuit breakers for power distribution...2 explanation...3
More informationZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS
Definition: Zone Selective Interlocking (ZSI) - A method which allows two or more ground fault breakers to communicate with each other so that a short circuit or ground fault will be cleared by the breaker
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationMedium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More information