FARROW SYSTEM OPERATING INSTRUCTIONS For Farrow 60 and units with previous generation control panels. Connecting the blast hose. Setting up the system

Size: px
Start display at page:

Download "FARROW SYSTEM OPERATING INSTRUCTIONS For Farrow 60 and units with previous generation control panels. Connecting the blast hose. Setting up the system"

Transcription

1 FARROW SYSTEM OPERATING INSTRUCTIONS For Farrow 60 and units with previous generation control panels Connecting the blast hose 1. Ensure the blast hose is laid out on the ground so there are no kinks 2. Connect blast hose and attach deadman lines Setting up the system 1. Fill water tank (both tanks on the Farrow185 ). Make sure tank drain(s) are closed (If there is a transfer pump on the Farrow185 please turn it on, this will move water from the left tank to the right tank) 2. Open air vent valve on pot and make sure the wash down valve is in the vertical-down position and the slurry valve is closed 3. Close both the abrasive dose and water dose valves 4. Turn on pot fill valve on top of control box to fill pot with water (faster method would be to use the hose if available), fill approximately for 3 minutes. 5. Turn off water; add abrasive blast media (2 bags max on Farrow60 / 3 bags max on Farrow185) 6. Once all media has been added, open pot fill valve to top off pot with water. As soon as bubble free water exits from air vent valve, close valve. 7. Close pot fill valve and fully open abrasive dose valve. 8. Lift pot seal and hold until pot seals and starts to pressurize. 9. Crack air vent valve quickly to release any trapped air in the pot. (may have to do a couple of times) 10. Watch pot pressure gauge (on control box door) should stop around psi. 11. Close abrasive dose valve and open approximately 1 ½ turns. Machine is now ready to use 1. When ready to blast pull up Emergency stop button, the machine is now controlled from the deadman handle. 2. Make sure the slurry valve is fully open 3. Make sure the blast gauge is adjusted to 50-55psi. FP Group LLC 705 H Old Westtown Rd. West Chester, PA 19382

2 When you stop blasting for more than a couple of minutes 1. Close slurry valve and press emergency stop button. 2. When ready to blast, reverse above steps. Adding abrasive media 1. Press emergency stop button. 2. Close slurry valve and close dosing valves 3. Open the air valve slowly to vent pot pressure and allow pot seal to drop. Leave open. 4. Open Dump valve to drain surplus water, making room to add more abrasive. (Farrow185 dump valve returns water to the left side tank/ Farrow60 just dumps to ground) 5. Add media. 6. Once all media has been added, close dump valve immediately and open pot fill valve to rinse media into pot and top off pot with water. As soon as bubble free water exists from air vent valve, close valve. 7. Close pot fill valve and fully open abrasive dose valve. 8. Lift pot seal and hold until pot seals and starts to pressurize. 9. Crack air vent valve quickly to release any trapped air in the pot. ( may have to do a couple of times) 10. Watch pot pressure gauge (on control box door) should stop around psi. 11. Close abrasive dose valve and open approximately 1 ½ turns. Machine is now ready to use 1. When ready to blast pull up Emergency stop button, the machine is now controlled from the deadman s handle. 2. Make sure the slurry valve is fully open Wash down mode 1. Close slurry valve and turn wash down valve lever to horizontal position (3 o clock). 2. Point hose away from surface and activate, let hose clear of media, approximately 1-2 minutes. 3. Start wash down 4. When done, return wash down valve and slurry valve to their original positions and you can start blasting again. FP Group LLC 705 H Old Westtown Rd. West Chester, PA 19382

3 Shutting the system down 1. When you finished blasting, carry out a short wash down procedure. 2. Wash down for 3-4 minutes to clear valves and hose of media. 3. Ensure emergency stop button is pushed down after completion and wash down valve is returned to vertical position. 4. While engine is running and pot is still pressurized making sure slurry valve is closed, remove the slurry pipe by undoing the coupling below the control panel. 5. Flush the control box of media by quickly turning the wash down valve to 3 o clock position and then back to vertical. 6. Slowly open the slurry valve into a bucket to capture any remaining media that may be reused in the future using the pot pressure to push out the slurry. 7. Let the pot completely drain of water and media, once empty, open pot fill valve and rinse top of pot and flush out any residual media still remaining in pot. 8. Reconnect slurry pipe and close slurry valve. 9. Shut down engine and drain water tanks. 10. Machine is now ready to be stored. FP Group LLC 705 H Old Westtown Rd. West Chester, PA 19382

4 FP Group LLC 705 H Old Westtown Rd. West Chester, PA 19382

5 FP Group LLC 705 H Old Westtown Rd. West Chester, PA 19382

6 FP Group LLC 705 H Old Westtown Rd. West Chester, PA 19382

FILLING AND PURGING THE SYSTEM

FILLING AND PURGING THE SYSTEM FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation

More information

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS

More information

ACCUMULATOR INSTALLATION

ACCUMULATOR INSTALLATION 7001-7 ACCUMULATOR INSTALLATION BRAKE ACCUMULATORS I 308L93 Rae 7-59710 Issued 6-93 Printed in U.S.A 7001-8 Removal ACCUMULATOR VALVE 1. Park the machine on a level surface and lower the. loader bucket

More information

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve

More information

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES The following are suggestions to help you winterize your home plumbing. They are for homes where the heat is not left on during the winter months. There

More information

93052/1115-V05. C260 User Manual

93052/1115-V05. C260 User Manual 93052/1115-V05 C260 User Manual QUICK GUIDE Preparing waste-holding tank 1 2 3 4 5 6 7 8 9 10 11 12 Preparing flush-water tank (only for C262-models) 13 14 15 16 Preparing Electric Ventilator (if applicable)

More information

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007 TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES 301.010 ANNUAL SERVICE TEST FOR FIRE HOSE EFFECTIVE: OCTOBER 2007 The Department will test all fire hose annually. The testing of fire hose determines its serviceability.

More information

Simply complete the enclosed Warranty Form with contact details, or email us with your details and date of purchase.

Simply complete the enclosed Warranty Form with contact details, or email us with your details and date of purchase. INSTALLATION & SERVICE GUIDE 4 STAGE UNDERSINK REVERSE OSMOSIS WITH SERVICE MODE Congratulations on your purchase of the most advanced Reverse Osmosis Water Purification system available. Part of our commitment

More information

Installation Instructions 4508 4508S

Installation Instructions 4508 4508S SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect

More information

I. Introduction. 10 minutes

I. Introduction. 10 minutes I. Introduction 10 minutes Introduction (1 of 2) An uninterrupted water supply is: The primary weapon for extinguishment Essential for fire fighter safety Ensuring a dependable water supply is a critical

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Before repairing your toilet, you must determine

Before repairing your toilet, you must determine Before repairing your toilet, you must determine which type of toilet you have. Pressurized Toilets If you have a pressurized toilet, it is recommended that you call a licensed plumbing contractor to repair

More information

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular

More information

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual Support Cleaning Apparatus Operation, Cleaning, & Safety Manual Revision 1.1 31 May 2014 WARNING: The instructions and precautionary statements contained herein are intended for the Support Cleaning Apparatus

More information

Lake Travis Lodges Marina Association

Lake Travis Lodges Marina Association Lake Travis Lodges Marina Association 2222 Western Trails Blvd. Suite #204 Austin, TX 78745 Ph: (512)266-3290 Fx: (512)266-6473 Pump Out Information Slip-Side Pump Out Information: M-Dock and L-Dock each

More information

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd. Jabiru Service Bulletin Number A3 Fuel System Cleaning Note on Revision 2. Revision 2 of this Service Bulletin updates the cleaning procedure using knowledge that has been gained by Jabiru. This revision

More information

Diagnosing Hydraulic Problems

Diagnosing Hydraulic Problems Diagnosing Hydraulic Problems 1 Problems A pressure test is a key check when you need to determine if a problem is caused by something that is inside or outside of the transmission. Low automatic transmission

More information

Inline Chlorinator Chlorine Chemical Feeder

Inline Chlorinator Chlorine Chemical Feeder Inline Chlorinator Chlorine Chemical Feeder Instructions Page 1 Chlorine setting in P.P.M. for center tube and cap Hole #1 = 2 P.P.M. Hole #2 = 8 P.P.M. Hole #3 = 30 P.P.M. Hole #A = 3.5 P.P.M. Hole #B

More information

FLUSHOMETER - TANK SYSTEM

FLUSHOMETER - TANK SYSTEM Owner s Service Manual 501-A Series FLUSHOMETER - TANK SYSTEM 501-A Series FLUSHMATE 501-A SERIES (D) (E) (C) 2 3 (B) 1 4 (F) (A) 6 5 List of Components for 501-A Series*: 1. Lower Supply Group w/hose

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate

More information

How To Replace A Reverse Osmosis Water Tank

How To Replace A Reverse Osmosis Water Tank ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.

More information

TRAINING BULLETIN Fire Apparatus Pump Test

TRAINING BULLETIN Fire Apparatus Pump Test TOPIC: TRAINING BULLETIN Fire Apparatus Pump Test EFFECTIVE DATE: 05/06 DOC NO: TB081 CROSS REF: INTRODUCTION District Fire Apparatus Pump Testing is completed on an annual basis. Currently, pump testing

More information

Installation Instructions 6028.801

Installation Instructions 6028.801 DAZZLE Installation Instructions 08.80 Spread Lavatory Faucet with Speed Connect Drain* Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American

More information

Cleaning instructions

Cleaning instructions 01 Siamonie 01 (TS) 415 00 904 01 Index 00 Date: 26 May 2014 Sielaff GmbH & Co. KG Automatenbau Postfach 20 D-91565 Herrieden Münchener Straße 20 D-91567 Herrieden Telephone: +49 (0) 9825 180 Telefax:

More information

Fiberstars Mini Lighted Laminar Flow Fountains

Fiberstars Mini Lighted Laminar Flow Fountains Fiberstars Mini Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Mini Lighted Laminar Flow Fountain. The

More information

Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam.

Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet Address: http://www.powerteam. ORIGINAL INSTRUCTIONS Form No.102842 5 SPX Hydraulic Technologies 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive

More information

B150 Series Commercial Brewer. Direct Plumb Kit

B150 Series Commercial Brewer. Direct Plumb Kit B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

Installer s Guide 18-AH39D1-13

Installer s Guide 18-AH39D1-13 18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,

More information

Assembly and instructions

Assembly and instructions Assembly and instructions Franke Minerva 3-in-1 Kettle Tap Retain for reference NB: For use only with Franke Heating Tank INTRODUCTION The Kettle Tap is suitable for dispensing boiling water (100 C) and

More information

Zenith Solar thermal 4.5m pump station Installation manual

Zenith Solar thermal 4.5m pump station Installation manual Zenith Solar thermal 4.5m pump station Installation manual Product code: 20026145 INSTALLATION MANUAL WATER RETURN GROUP This instruction manual is an integral part of the installation and maintenance

More information

PC1131 Electric Air Compressor

PC1131 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in

More information

COUNTERBALANCE VALVES

COUNTERBALANCE VALVES COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load

More information

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA SOP#: 1005.7 Date Issued: 10/98 Date Revised: 2/16 Page 1 of 7 TITLE: SCOPE: RESPONSIBILITY: PURPOSE: Animal Care

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS THE LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT

More information

copy The New CFD Rabbit Tool: TNT FE-5.0 Forcible Entry Tool

copy The New CFD Rabbit Tool: TNT FE-5.0 Forcible Entry Tool copy The New CFD Rabbit Tool: TNT FE-5.0 Forcible Entry Tool CFD Companies currently assigned to receive 24 new TNT Forcible Entry Tools: 1) All 11 Hook and Ladder and Tower companies. 2) *All single-engine

More information

BERMAD Fire Protection

BERMAD Fire Protection Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around

More information

MODEL WEB CONTENT FOR CITY SANITARY SEWER DEPARTMENTS

MODEL WEB CONTENT FOR CITY SANITARY SEWER DEPARTMENTS MODEL WEB CONTENT FOR CITY SANITARY SEWER DEPARTMENTS The following information is designed to be used in conjunction with the Sewer Toolkit, located in the Wastewater section of the Florida Rural Water

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

Line to Refrigerator Ice/Water Dispenser

Line to Refrigerator Ice/Water Dispenser Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon

More information

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use. OFF COOL 0 3 2 1 OFF Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use ON SPEED ON SWING OWNER S MANUAL Read and save these instructions before use Model: CO60PM Power rating: 220 Watts

More information

1. Description. 2. List of Accessories included A B C F G H

1. Description. 2. List of Accessories included A B C F G H 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to

More information

PC1130 Electric Air Compressor

PC1130 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in

More information

Ambiente Quick Reference Manual

Ambiente Quick Reference Manual Ambiente Quick Reference Manual Schaerer USA Corporation 2900 Orange Avenue, Suite 102 Signal Hill, CA 90755 Phone (888) 989-3004 Fax (562) 989-3075 TABLE OF CONTENTS Machine Overview Page 1 Button Panel

More information

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Coolflo Safe Touch Shower Mixing Valve ST20015CP Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP Feb 5, 2003 1 CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING COMPLETE SYSTEM CHECK - PNEUMATIC PUMP THE SYSTEM DOES

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Iron Air Charge 2510-SXT Installation & Start-Up Guide Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water

More information

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and

More information

7500 Pro-Ox Filter Installation & Start-Up Guide

7500 Pro-Ox Filter Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com 7500 Pro-Ox Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your

More information

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50 Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood

More information

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical

More information

Firefighter Review. Instructor Guide

Firefighter Review. Instructor Guide Firefighter Review Instructor Guide Session Reference: 3 Topic: Attack Line Handling Level of Instruction: Time Required: Three Hours Materials: Two Fully Equipped Pumpers Structure for Use in Advancing

More information

TOBY DVR5 OIL CONTROL & SAFETY VALVE

TOBY DVR5 OIL CONTROL & SAFETY VALVE TOBY DVR5 OIL CONTROL & SAFETY VALVE TECHNICAL HANDBOOK Principle of Operation The Toby DVR5 Oil Control Valve is a multi function unit for maintaining a constant oil level, regulating the oil flow and

More information

Waste Collection Systems

Waste Collection Systems Waste Collection Systems System Maintenance and Repair Maintenance and Repair Training Objectives To gain an understanding of: System Maintenance and Repair vocabulary System Maintenance and Repair techniques

More information

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety

More information

Apricot Kitchen Sink Tap

Apricot Kitchen Sink Tap Apricot Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

NESCAFÉ Solution 8/60 Beverage System. Operations Manual NESCAFÉ Solution 8/60 Beverage System Operations Manual 1 INDEX & WARNINGS INDEX Warnings SECTION: 1 INDEX & WARNINGS SECTION: 2 BASIC PARTS OF THE MACHINE SECTION: 3 LOADING PRODUCTS SECTION: 4 DISPENSING

More information

Hydraulic control unit series 0086-372-01

Hydraulic control unit series 0086-372-01 Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3

More information

*h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5, <$1/,ù0217$-'$1.$<1$./$1$%ø/ø5 &ø+$=,$6/$d$/,ù0$67$1',h=(5ø1'( 7$ù,0$<,1,=

*h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5, <$1/,ù0217$-'$1.$<1$./$1$%ø/ø5 &ø+$=,$6/$d$/,ù0$67$1',h=(5ø1'( 7$ù,0$<,1,= 10600834.fm Page 1 Thursday, January 11, 2007 6:07 PM TR 0217$-.,/$98=8 *h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5,

More information

Coffee Maker Senseo HD7820/70

Coffee Maker Senseo HD7820/70 Coffee Maker Senseo Philips Domestic Appliances and Personal Care Service Manual PRODUCT INFORMATION - This product meets the requirements regarding interference suppression on radio and TV. - After the

More information

DRAIN, WASTE AND VENT PLUMBING

DRAIN, WASTE AND VENT PLUMBING Flow of waste in a drain system Solid and liquid waste flows in vertical pipes much differently than it does in horizontal systems. In near horizontal pipes we talked about maintaining the slope of the

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

TUTTNAUER OLD AUTOCLAVE OPERATING PROCEDURE

TUTTNAUER OLD AUTOCLAVE OPERATING PROCEDURE 1 of 6 TUTTNAUER OLD AUTOCLAVE OPERATING PROCEDURE Aim The aim of this operating procedure is to equip the user with the knowledge to safely and successfully operate the old pressure chamber. This autoclave

More information

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS GAP.14.1.2.2 A Publication of Global Asset Protection Services LLC WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS INTRODUCTION A hydrant or other large-volume flow test is necessary for proper water

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

Coal fired steam locomotive CHARYBDIS

Coal fired steam locomotive CHARYBDIS Coal fired steam locomotive CHARYBDIS Owners Manual Contents Locomotive running tools Controls Running in Preparing to run your locomotive Running your locomotive Once you have finished your running session

More information

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS 1 TM INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS When the HI-FLO Metering Head is attached to a tank, the tank will be pressurized to the same pressure as the irrigation system. Before attaching

More information

Draining and filling cooling system

Draining and filling cooling system Page 1 of 9 Draining and filling cooling system Special tools and workshop equipment required Adapter -V.A.G 1274/8- Pipe -V.A.G 1274/10- Drip tray -V.A.G 1306- or drip tray for workshop hoist -VAS 6208-

More information

Service Manual. Coffee maker Senseo Viva Café HD7825/30 10/05. Philips Consumer Lifestyle

Service Manual. Coffee maker Senseo Viva Café HD7825/30 10/05. Philips Consumer Lifestyle Coffee maker Senseo Viva Café Philips Consumer Lifestyle Service Manual PRODUCT INFORMATION - This product meets the requirements regarding interference suppression on radio and TV. - After the product

More information

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER 123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual

More information

TROUBLESHOOTING FLOW CHART

TROUBLESHOOTING FLOW CHART TROUBLESHOOTING FLOW CHART Revised and updated on January 16, 2003, by Tony Leger and Automation Lab Technology. FACScan(FC)\FACSort(FST) FACScalibur (FCB) Fluidics/Pneumatics troubleshooting guide DCM

More information

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Fiberstars Lighted Laminar Flow Fountain Installation Manual Fiberstars Lighted Laminar Flow Fountain Installation Manual 79-15037-00 REV Xx http://www.fiberstars.com Page 1 of 8 SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation

More information

Dentalaire Owner s Manual for all Dental Stations

Dentalaire Owner s Manual for all Dental Stations Dentalaire Owner s Manual for all Dental Stations DENTALAIRE SET UP PROCEDURE FOR DENTALAIRE DENTAL STATIONS STEP # 1 - Open crate using a large screwdriver. Please check crate for any damages and report

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

CAP.1 INTRODUCTION... 2

CAP.1 INTRODUCTION... 2 FX-44 Operation Manual CAP.1 INTRODUCTION... 2 CAP.2 DISHWASHER HANDLING AND TRANSPORT... 3 2.1 Transport and packing... 3 2.2 Handling... 3 CAP.3 DANGER ZONES AND SAFETY MECHANISMS... 3 3.1 Danger of

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

Operation & Maintenance Manual

Operation & Maintenance Manual Manual # OMAV2-SUMP1 High Performance Air & Dirt Separators Manual # 9636-1230 Rev. A Operation & Maintenance Manual 340 West 8 th Street Peru, IN 46970 PH: 765 472 3351 FX: 765 472 3968 www.thrushco.com

More information

Almond Kitchen Sink Tap

Almond Kitchen Sink Tap Almond Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

Auto-belay Cable Replacement Process

Auto-belay Cable Replacement Process Auto-belay Cable Replacement Process Version 2.00 WARNING: The air pressure in the auto-belay system is what causes the cable to be retracted when releasing the cable or climbing the wall with the cable

More information

Liquorice Kitchen Sink Tap

Liquorice Kitchen Sink Tap Liquorice Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

ENTERALITE INFINITY PUMP Instructions for use

ENTERALITE INFINITY PUMP Instructions for use ENTERALITE INFINITY PUMP Instructions for use Key points: 1. Wash your hands with antibacterial soap before handling your feeding tube and supplies. 2. If you have more than one catheter (example: feeding

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves CRANE Energy Flow Solutions TM Donald H. Johnson Crane Energy Flow Solutions 1 Crane Co. Resolution Made By Richard Teller

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

Fact Sheet on Steam Sterilizers at Stanford University

Fact Sheet on Steam Sterilizers at Stanford University Fact Sheet on Steam Sterilizers at Stanford University By: Environmental Quality and Water Efficiency Group, Stanford University; December 2013 Jennifer Fitch, Marty Laporte, Julia Nussbaum, Adam Kern,

More information

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw

More information

Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller

Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Specifications Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller Introduction These purchase specifications cover the minimum requirements of a Single Deadman Air Lifting Bag (ALB) Controller

More information

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Dry Cleaner Compliance Calendar 2012

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Dry Cleaner Compliance Calendar 2012 NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM Dry Cleaner Compliance Calendar 2012 Welcome The New Jersey Small Business Environmental Assistance Program developed this guidance document to

More information

OWNER S MANUAL. Remote Control Valves RMS 2000, 1500, 500

OWNER S MANUAL. Remote Control Valves RMS 2000, 1500, 500 OWNER S MANUAL Remote Control Valves RMS 2000, 1500, 500 Clemco International GmbH Carl-Zeiss-Straße 21 Tel.: +49 (0) 8062 90080 83052 Bruckmühl Mail: info@clemco.de Germany Web: www.clemco-international.com

More information

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com 123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer

More information

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 ABSORPTION OF CARBON DIOXIDE INTO WATER

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 ABSORPTION OF CARBON DIOXIDE INTO WATER UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 ABSORPTION OF CARBON DIOXIDE INTO WATER OBJECTIVE The objective of this experiment is to determine the equilibrium line,

More information

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit. 1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to

More information

Winterizing Your Trailer and Storage Ideas

Winterizing Your Trailer and Storage Ideas Winterizing Your Trailer and Storage Ideas Basically winterizing is getting the water out of the pipes and tanks so that when it gets cold enough to freeze water, your unit won't be damaged from the expanding

More information