Great job! The AGGRAND Department
|
|
- Dwain Kelley Boyd
- 7 years ago
- Views:
Transcription
1 AGGRAND would like to thank AGGRAND Dealer Tony Zilar for sharing his spray tank project with all our Dealers and customers. It is a wonderful design and well documented, step by step, presentation. Great job! The AGGRAND Department
2 Boom Sprayer project at A2Z Ranch, Kennewick, Washington by Anthony Zilar AGGRAND dealer (509)
3 Objective Build a boom sprayer that is simple, versatile and maximizes the effectiveness of AGGRAND products System must: Compliment AGGRAND products Be capable of various application needs Be able to be used with tractor or truck Provide simple, time efficient operation Be large capacity yet easily transported Offer cost effective construction
4 Primary considerations to ensure boom sprayer compliments AGGRAND products: Manage particulate matter to include bone meal and liquid lime Adequate tank agitation to maintain product suspension Effective fluid screening without compromising pressure or flow Nozzle selection
5 Purchase a used boom sprayer chassis and 500 gallon polymer tank. Fabricate motor and valve mounts and weld modifications and structural improvements Sand blast Prime and paint with an industrial protective coating Treat the tank with a chemical neutralizer
6 Mount tires and rims that will provide adequate floatation and tracking. Weight capacity is a primary consideration.
7 Install a gas powered motor and centrifugal pump to provide a self-contained power/pressure source. Honda motor (model GX160) 4.8 bhp at 3600 rpm - Engine throttle is the primary means for adjusting sprayer pressure ACE pump (model GE660) max pressure 115 psi, max flow 110 gpm
8 Install the plumbing with a simple layout plan: One line from the holding tank to the pump intake One line from the pump discharge to a combination bypass and in-line strainer system One line from the bypass output back to the holding tank through the agitators One line from the in-line strainer output to the boom valve manifold
9 Pump discharge line to the combination strainer intake In-line strainer output to the boom valve manifold Bypass output free-flowing back to the holding tank
10 Particulate matter will not pass through the in-line filter but will flow freely through the bypass back to the holding tank to be re-circulated. Particulates will eventually break down through agitation and pump sheering action. Free-flow pressure back to the holding tank can be adjusted by an in-line valve to prevent foam build-up in the tank. This valve can also be used for fine-tune nozzle pressure adjustments (up to 6 psi adjustment).
11 (View inside the holding tank from the top port looking down to the tank floor.) Dual jet agitators inside the holding tank provide excellent product suspension.
12 The manifold directs the flow of the strained fluid to valves leading to the starboard, port and mid booms. The hose to the pressure gauge originates at the manifold.
13 From the boom valves, the fluid flows through in-line filters before being discharged at the nozzles. These in-line filters are used in lieu of nozzle screens to reduce the occurrence of nozzle fouling.
14 Remove nozzle screens.
15 Select Turbo floodjet nozzles (Teejet TS-4) to maximize AGGRAND products potential.
16 This basic system compliments AGGRAND products well. No concern for particulates causing obstruction Powerful pump provides adequate shearing action Free-flow return through a bypass strainer to the holding tank keeps particulates cycling Agitators assist in particulate break down
17 Product suspension and uniform mixture is adequately maintained in the holding tank. Agitators provide a well-designed current Holding tank foaming can be controlled without adding chemicals by adjusting the free-flow return with a simple valve.
18 Adequate filtering is achieved Filtering is accomplished on the output side of the pump providing maximum pressure capabilities. (System is capable of producing >80 psi at the nozzles) Screen fluid twice well before it reaches the nozzles to prevent nozzle fouling. Nozzle screens are not required.
19 The goal of building a boom sprayer system that compliments AGGRAND products is easily accomplished. However, additional considerations should be made to enhance the operation and versatility of the sprayer system.
20 Install a shut-off valve between the holding tank and pump intake. A capped secondary intake port can be placed between the valve and the pump intake. This provides the flexibility of pumping water into the holding tank from a supplemental source if field expedient water sources need to be considered.
21 Use quick release/attach fittings at the holding tank purge port, bypass output port and secondary intake port.
22 Install electric valves to allow easy, remote boom valve operation from inside the cab of a truck or tractor.
23 An electric air compressor, mixing tank, electric valve, tubing and foam collectors can be installed to provide an excellent foam marker system to compliment the overall efficiency of the boom sprayer system.
24 You can build a remote controller box using switches purchased from a local electronics store. A cigarette lighter/electrical accessory plug can be incorporated as the link to the towing vehicle electric power source. A standard 7-pin towing plug and receiver can be used to attach the remote box to the boom sprayer trailer. I used 15 feet of wire lead to ensure the controller box could reach the cab of a truck or tractor.
25 In-line fuse Primary power switch Boom valve switches Foam compressor power switch Foam valve left/right selector switch
26 Booms fold for easy transport. The mid boom section can still be operated while the port and starboard booms are folded. This will provide over ten feet of spray coverage.0
27 Place spray nozzles on 22 inch centers a total of 23 nozzles to fully utilize the 40 feet of boom capacity. If all 23 nozzles are used, 100% overlap will occur. Every second nozzle can be replaced by a port plug to limit the functioning nozzles to a total of 12 at 30% overlap. This unique nozzle layout further adds to the flexibility of the sprayer system. Applications can be customized to accommodate for different spray products, nozzle tips, soil conditions, crops, and weather considerations.
28 It s time to go to work
Auto Boom Breakaway High Floatation Tires (20 x 10 x 8.0) Adjustable Hitch Height 1 Year Sprayer Warranty Manual Boom Section Control
F/S ATV Maxi 18 Maxi s Walking Tandem Axles Axles Adjust for Row Spacing 4 HP Honda Engine with 22.5 GPM Centrifugal Pump Designed to be Pulled by a Larger ATV or Small Utility Tractor Add Spot Spraying
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More information123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
More informationATV 50/100 Gallon Skid Sprayers
F/S ATV 50/100 Gallon Skid s Standard Adjustable Swing-Away Control Arm Master Shut-off Left/Right Shut-off Valves at Booms Pressure Regulator & Liquid-Filled Gauge Standard TeeJet Components Full-Drain
More information123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
More informationCDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
More informationAssembly / Operation Instructions / Parts
Assembly / Operation Instructions / Parts TSU SKU# 00 VENDOR# ATV BL CL DELUXE ATV BOOMLESS SPRAYER Polyethylene Tank Volt Diaphram Pump.0 G.P.M. Lever Handgun Ft. of / Hose (handgun) Pressure Gauge Adjustable
More information123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
More informationTRAINING BULLETIN Fire Apparatus Pump Test
TOPIC: TRAINING BULLETIN Fire Apparatus Pump Test EFFECTIVE DATE: 05/06 DOC NO: TB081 CROSS REF: INTRODUCTION District Fire Apparatus Pump Testing is completed on an annual basis. Currently, pump testing
More informationAgri-Fab OWNERS MANUAL. Model No. 45-02931 25 GALLON "PRO" TOW SPRAYER
Agri-Fab OWNERS MANUAL Model No. 45-02931 CAUTION: Read Rules for Safe Operation and Instructions Carefully Assembly Operation Maintenance Repair Parts 25 GALLON "PRO" TOW SPRAYER the fastest way to purchase
More informationOWNERS MANUAL. Model No. 45-0292 15 GALLON "PRO" TOW SPRAYER
OWNERS MANUAL Model No. 45-0292 CAUTION: Read Rules for Safe Operation and Instructions Carefully Assembly Operation Maintenance Repair Parts 15 GALLON "PRO" TOW SPRAYER PRINTED IN USA FORM NO. 47628 (REV.
More informationBig Rig Spray Systems. Waterproofing Air/Vapor Barrier Commercial Roofing Floor / Protective Coatings
Big Rig Spray Systems Waterproofing Air/Vapor Barrier Commercial Roofing Floor / Protective Coatings Spray equipment packages for your applications We specialize in equipment to spray, dispense, measure,
More information53403500 - Injector Max Machine
53403500 - Injector Max Machine Operating Instructions Contents Page Introduction Operating Instructions Fuel Injection Cleaner - Petrol Operating Instructions Fuel Injection Cleaner - Diesel 3 Operating
More informationElement D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
More informationPUMP MAINTENANCE SCHEDULE AND CHECKLISTS
PUMP MAINTENANCE SCHEDULE AND CHECKLISTS Providing a maintenance schedule defined specifically by run hours or yardage pumped serves only as a general guideline given the large amount of variables a unit
More informationSprayer Calibration By Mark Halcomb, UT Extension Area Nursery Specialist (Revised 7-21-2012)
1 Sprayer Calibration By Mark Halcomb, UT Extension Area Nursery Specialist (Revised 7-21-2012) Calibration is the process of modifying or adjusting a sprayer to give the desired application rate with
More informationQuik Lining Systems Heater Owners Guide
Quik Lining Systems Heater Owners Guide Quik Lining Systems, Inc is pleased to present the Quik Heater, an innovative heater used to cure cured in place pipe for sewer laterals. The unit is the most cost
More informationAKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
More informationCentrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
More informationGoulds Water Technology
APPLICATIONS Specifically designed for: Homes Farms Cottages Booster service SPECIFICATIONS Pump: Pipe connections: 1¼" NPT suction, 1" NPT discharge, 1" NPT drive (pressure) Pressure switch: AS4 preset
More informationAir Dryer Application Guidelines
$2.50 Air Dryer Application Guidelines TP-9672 Revised 11-98 System Saver 1000 and 1200 Series System Saver TWIN Table of Contents Introduction Purpose of This Guide.................................................................
More information400B SERIES DIAPHRAGM PUMP
400B SERIES DIAPHRAGM PUMP In today s agricultural and industrial markets, isn t it good to know that you can rely on one name Sotera to fit your chemical transfer needs? The Sotera 400B Series offers
More informationSpare Parts Program. Parts, Consumables & Accessories. 800.837.9711 superproductsllc.com
Spare Parts Program Parts, Consumables & Accessories TABLE OF CONTENTS Program Introduction 3 Body 4 5 Boom 5 6 Hydraulic 6 Lights & Accessories 7 Tubes, Nozzles & Hose Fittings 8 11 Vacuum 11 Water 12
More informationSERVICE PARTS INSTRUCTIONS
WACO MERITOR SERVICE PARTS INSTRUCTIONS Installing the Meritor WABCO System Saver 1000 and 1200 Series Air Dryers For Use on Tractors, Trucks and Buses with Air Brakes Installation Requirements 5 P/N 434
More informationMUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
More informationHeavy-Duty Lube and Fuel Truck Sales Tool
Heavy-Duty Lube and Fuel Truck Sales Tool Contact: Adrian Britt or Mike Kelley @ (678) 639-0099 33,000 lb. Lube/Fuel Truck Contact: Adrian Britt or Mike Kelley @ (678) 639-0099 Example Specification
More informationWestern Plant Health Association DOT MC 330 & 331 NH3 Cargo Tank Inspection Checklist Form
Western Plant Health Association DOT MC 330 & 331 NH3 Cargo Tank Inspection Checklist Form Title 49CFR Parts 107 through 180 & Parts 385-399 / CCR Title 8 409 / 29CFR 11910.11(b)(10) Company Name: NH3
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More informationON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
More informationOptimizing Tank Cleaning Operations
Optimizing Tank Cleaning Operations Choosing the best way to thoroughly clean your tanks while minimizing use of costly chemicals, water and manual labor can be challenging. There are several things you
More informationThe On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.
«1A: Description and Operation» Overview The Evaporative Emission (EVAP) system prevents fuel vapor build-up in the sealed fuel tank. Fuel vapors trapped in the sealed tank are vented through the vapor
More informationStandard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
More informationHYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
More informationBLADDER SURGE CONTROL SYSTEM
PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures
More informationGE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping
GE Oil & Gas Texsteam * Pumps: precise chemical injection pumping 2 With a wide range of capacities and operating pressures, GE s versatile Texsteam pumps can handle challenging chemical pumping requirements
More informationMAKE OF AUTOMOBILE: NUMBER : 076/0800901 DATE : 2008-12-08 Copyright Prins Autogassystemen B.V. 2008 VERSION NR : 2008-10-24 B
MAKE OF AUTOMOBILE: HONDA TYPE: CIVIC PISTON DISPLACEMENT: 1800 NUMBER OF VALVES: 16 ENGINE NUMBER: R18A TYPE VSI INJECTOR ( COLOR ) ORANGE MODEL YEAR: 2008 ENGINE SET NUMBER 348/0250200.07 NUMBER : 076/0800901
More informationSignature and ISX CM870 Electronics
Signature and ISX CM870 Electronics Cummins West Training Center System Description General Information The Signature and ISX CM870 engine control system is an electronically operated fuel control system
More informationPumping Fuel & Fuel Oil
Pumping Fuel & Fuel Oil Fuels & Rotary Pumps Though the handling of fuel oil is not necessarily "challenging," the reliable handling of fuel oils is critical for heating and transportation systems. Rotary
More informationHow To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
More informationE - THEORY/OPERATION
E - THEORY/OPERATION 1995 Volvo 850 1995 ENGINE PERFORMANCE Volvo - Theory & Operation 850 INTRODUCTION This article covers basic description and operation of engine performance-related systems and components.
More informationInspection and Testing of Water-Based Systems
Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level III Content Outline The candidate for NICET certification at Level III in the Inspection and Testing of Water-Based
More informationSERIES HYDRAULIC MOTOR DRIVEN CENTRIFUGAL PUMPS
INSTRUCTION MANUAL OASIS WetSeal Technology T M MAX SERIES HYDRAULIC MOTOR DRIVEN CENTRIFUGAL PUMPS 1 2 TABLE OF CONTENTS Pump performance data, dimensions, and part listings are on individual pump specification
More informationELECTRIC/DIESEL FIRE PUMP CHECK LIST
BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested
More informationDESTROKED. Circuits that will be run through the Ford PCM and Ford Engine Harness
DESTROKED Thank you for your interest in Destroked. Please read through this overview to get a good idea of what is involved in your Cummins conversion project. Circuits that will be run through the Ford
More informationDiagram of components 2. Reducer..3
Index Diagram of components 2 Reducer..3 Rail Filter - Rail Filter 4 - MAP Sensor.4 Injector & Nozzle - Single Injector / Rail Injector...5 - Bi-Fuel Connector...6 - Nozzle...7 ECU...8 Switch 9 Wiring
More informationModulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.
Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,
More informationWater Wash Spray Booth Paint Sludge Recovery
Water Wash Paint Spray Booth Sludge Removal, Water Curtain Paint Wastewater Treatment, Paint Sludge Separation and Dewatering, Paint sludge removal centrifuge, Palin paint sludge dewatering Since 1991
More informationWildland Fire Remote Monitor
K A N S A S F O R E S T S E R V I C E KANSAS STATE UNIVERSITY Wildland Fire Remote Monitor For years, fire department administrators have struggled to find an alternative to having firefighters ride on
More informationOREGON FIRE CODE Interpretations and Technical Advisories
OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application
More informationUnit 8. Conversion Systems
Unit 8. Conversion Systems Objectives: After completing this unit the students should be able to: 1. Describe the Basic conversion systems 2. Describe main conversion kit types. 3. Describe how the CNG
More informationRecommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
More informationTROUBLESHOOTING GUIDE
RJS SELF-PRIMING SHALLOW WELL JET PUMPS a. Motor will not start: 1. No power to pressure switch due to blown fuses, open switches or loose connections. 2. Pump pressure switch not closed. b. Pump fails
More informationBasic Hydraulics and Pneumatics
Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:
More informationTable V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
More informationAIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
More informationWANJET. Sprayers. Wanjet sprayers has been produced since 1978.
Sprayers Wanjet sprayers has been produced since 1978. Already from beginning was our assortment mainly based on high pressure sprayers with a pressure up to 150 bar. The idea about the high pressure is
More informationAIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION
AIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION Tony Thorne Manager of Electrical Engineering Index Sensors and Controls, Stanwood, WA 98292 USA ABSTRACT Air conditioning
More informationAir Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
More information2003-2004: Service Information: Fuel Tank System
2003-2004: Service Information: Fuel Tank System Corvette and Cadillac XLR Partway through model year 2003, a new fuel tank system was introduced on the Corvette (fig. 1). This system continues with slight
More informationMODEL #12006. Introduction
THE ORIGINAL PECO POWER SPRAYER PECO OWNER S MANUAL MODEL #12006 (Q0080) Revised: 1/8/2014 PECO POWER SPRAYER MODEL #12006 TABLE OF CONTENTS SECTION PAGE SECTION PAGE INTRODUCTION - - - - - - - - - - -
More informationIntroduction to and Operation of Compressed Air Foam Systems (CAFS)
Compressed Air Foam Systems (CAFS) Mesa Fire Department currently has nine (9) compressed air foam pumpers. Each unit has 20 to 30 gallons of Class A foam on board. Typical compressed air foam is available
More informationPC1130 Electric Air Compressor
Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1130 Electric Air Compressor Operating Instructions 2006 by Senco Products, Inc. Warnings for the safe use of this tool are included in
More informationDESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
More informationBuy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.
Karcher Model: K 620-M * ( 59556440 ) - Parts Section:1.1 TOP PART Page 1 of 18 1 50346460 1 STRAP 2 63031250 6 SCREW 3 50670230 1 COVER 4 63031940 2 SELF-TAPPING SCREW 5 50309650 1 COVER 6 50635710 1
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationHydraulic Trouble Shooting
Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders
More informationA.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line
More informationOPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES
OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES Reference: National Fire Protection Association (NFPA) Pamphlet No. 58 Liquefied Petroleum Gas Code, 2001, Chapter 11 Type of Facility: Petroleum
More informationFILLING AND PURGING THE SYSTEM
FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation
More information77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION
SUBPART I: WATER SUPPLY AND DISTRIBUTION Section 890.1110 Quality of Water Supply All premises intended for human habitation or occupancy shall be provided with a potable water supply. The potable water
More informationEmergency Response Guide
Emergency Response Guide Honda Natural Gas Vehicles This publilcation covers these Civic Natural Gas Models: 1998-2000 2001-2005 2006-2011 2012 Prepared for Fire Service, Law Enforcement, Emergency Medical,
More informationPump Ratio and Performance Charts
Pump Ratio and Performance Charts Concept and Theory Training Table of Contents Introduction... 1 Overview... 1 How to use this Module... 2 Learning Objectives...2 Text...2 Charts, Illustrations...2 Progress
More informationSIMPLE... AFFORDABLE... ENERGY EFFICIENT... LOW MAINTENANCE...
YIELD SIMPLE... AFFORDABLE... ENERGY EFFICIENT... LOW MAINTENANCE... Energy Efficient Engineering Water Solutions The System from Inc. is a revolutionary new mobile advanced treatment system platform.
More informationDimension Specifications
Dimension Specifications Note: Dimensions are dependent on chassis selection, optional equipment and water capacity. Vactor 2110 Positive Displacement Single rear axle WB 255 in (5,715 mm) CA 156 in (3,962
More informationPlant components, selected for sound performance
Plant components, selected for sound performance Selected plant components to meet our customers demands We provide a wide range of plant components offering lowest cost of ownership, high product safety
More informationPressure Vessels (Air Compressors) and LPG Tanks
Pressure Vessels (Air Compressors) and LPG Tanks 1. Identification of Workplace Hazard Any container, tank or vessel that contains pressurized material is a potential hazard to employees due to the force
More information11101, 11108 & 11151 INSTALLATION INSTRUCTIONS
11101, 11108 & 11151 INSTALLATION INSTRUCTIONS WARNING! The fuel system is under pressure. Do not open the fuel system until the pressure has been relieved. Refer to the appropriate vehicle service manual
More informationACCUMULATOR INSTALLATION
7001-7 ACCUMULATOR INSTALLATION BRAKE ACCUMULATORS I 308L93 Rae 7-59710 Issued 6-93 Printed in U.S.A 7001-8 Removal ACCUMULATOR VALVE 1. Park the machine on a level surface and lower the. loader bucket
More informationMechanical Seal Piping Plans
Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,
More informationInstallation, Operation, Repair and Parts Manual
Description Series 9700 Close-Coupled AC Motor-Driven and Pedestal Mount Centrifugal Pumps Installation, Operation, Repair and Parts Manual Form L-0350C Rev. B Hypro's 9700 series pumps are specifically
More information1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to 9.0 3. Nonvolatile TOC content < 1.0 ppm
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationNAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
More informationStandard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
More informationBLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants
BLASTING SYSTEMS Turbine blasting systems Air blasting systems Automatic Painting plants 1, Dust Collector 2, Cyclone Separator 3, Sand (shot) Storage Hopper 4, Bucket elevator 5, Primary separator 6,
More informationOASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)
OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12) Revision 1.0 Page 1 of 50 THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE SOLE PROPERTY OF INTERNATIONAL THERMAL RESEARCH, LTD. ANY REPRODUCTION
More informationaccidents which arise due to nonobservance and the safety information herein.
20 GALLON COMPRESSOR Model: 7342 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This
More informationSprayers and Other Equipment for Orchard Maintenance
A L A B A M A A & M A N D A U B U R N U N I V E R S I T I E S ANR-53-P F r u i t C u l t u r e i n A l a b a m a Sprayers and Other Equipment for Orchard Maintenance Sprayers Safe and efficient application
More informationMidwest Industrial Tanks
FOR AGRICULTURE AND INDUSTRY Midwest Industrial Tanks Fuel & Oil Storage Solutions Midwest Industrial Tanks Is Your Source For All Of Your Fuel Storage And Fuel Transportation Needs. Our Satisfied Customers
More informationExample. Fluid Power. Circuits
Example Fluid Power Circuits To Enhance Symbol Reading Skills To Work On Circuit Reading Skills With Answers HI LO Pump Circuit 18 A1 B1 17 16 15 13 Set 14 2,000 PSI PG2 Set 500 PSI 12 11 7 8 10 PG1 9
More informationNot required for most applications Not required for most applications High pressure (12-803 provided) High pressure (12-803 provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 712-802-1, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-803, 12-501, 12-804, 12-500, & 15812NOS Installation Instructions THESE INSTRUCTIONS
More information25 and 45 GALLON Premium Tow-Behind Sprayer
25 and 45 GALLON Premium Tow-Behind Sprayer MODEL NUMBERS: 25 Gal. - 40-1105 45 Gal. - 40-1110 OWNER S MANUAL CUSTOMER MUST RECEIVE A COPY OF THIS OWNER S MANUAL AT TIME OF SALE 1701 38th Ave. West PO
More informationAn Engineering Guide to Modern Fuel Systems
An Engineering Guide to Modern Fuel Systems This publication is intended as a resource for designers, installers, and system operators. In this document we highlight the typical indoor components and operational
More informationTOPIC: 191004 KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?
KNOWLEDGE: K1.01 [3.3/3.5] P21 Which one of the following contains indications of cavitation in an operating centrifugal pump? A. Low flow rate with low discharge pressure. B. Low flow rate with high discharge
More informationFluid Monitoring and Inventory Management
SECTION FOUR Fluid Monitoring and Inventory Management Introduction Alemite meets your fluid monitoring and inventory management needs with its Accu-Guard systems and its Bigview Tank Monitor. These systems
More informationLine to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
More informationEmergency Response Guide
Emergency Response Guide Honda CNG Vehicle Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc. Contents Key Components 1
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationBack Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50
Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood
More informationModel 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
More informationNational System of Garage Ventilation s Engineering Guide
National System of Garage Ventilation s Engineering Guide In designing a fume removal system, it is extremely important to determine the following: 1. Type of apparatus to be exhausted (i.e. gasoline,
More information