Agilent 6890 Plus GC. Specifications: 6890 Plus Agilent GC, FID Single Capillary Inlet w/epc $15,500. Dimensions and Average Weight

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Agilent 6890 Plus GC. Specifications: 6890 Plus Agilent GC, FID Single Capillary Inlet w/epc $15,500. Dimensions and Average Weight"

Transcription

1 Agilent 6890 Plus GC >Home >Gas Chromatographs >Agilent 6890 Plus GC >More Info. $15,500 Specifications: 6890 Plus Agilent GC, FID Single Capillary Inlet w/epc Dimensions and Average Weight Height: 50 cm (19.7 in.) Width: 58 cm (26.8 in.) Depth: 54 cm (21.6) Average Weight: 49 kg (108 lb) Environmental Conditions Ambient Operating Temperature: 15 Celsius to 35 Celsius Ambient Operating Humidity 5-95% Storage Extremes -40 Celsius to 65 Celsius Safety and Regulatory Certifications Conforms to the following safety standards: Canadian Standards Association (CSA): C22.2 No CSA/Nationally Recognized Test Laboratory (NRTL): UL3101 International Electrotechnical Commission (IEC): EuroNorm (EN): Conforms to the following regulations on Electromagnetic Compatibility(EMC) and Radio Frequency Interference(RFI): CISPR 11/EN 55011: Group 1 Class A EN Designed and manufactured under a quality system registered to ISO 9001 Declaration of Conformity available Column Oven (1 of 5) [21/08/ :57:27]

2 Dimensions: Operating temperature: 28x31x16 cm 4 Celsius above ambient to 450 Celsius -With LN 2 cryo: -80 Celsius to 450 Celsius -With CO 2 cryo: -55 Celsius to 450 Celsius Temperature setpoint resolution: 1 C Max. temperature ramp rate: 120 C/min Max. run time: min Temperature programming ramps/plateaus: 6/7 Ambient rejection: Less than 0.01C per 1C Column breed compensation standard for two channels Typical Oven Ramp Rates Temperature Range ( C) Standard Oven Rates ( C/min) Fast-Ramp Rates* ( C/min) *Fast-ramp rates require power > 200 volts at > 15 Amps. Heated Zones -Independent heaed zones, not including oven: six (two inlets, two detectors, and two auxiliary) -Maximum operating temperatures for auxiliary zones: 400 C Electronic Pneumatics Control (EPC) Up to 13 EPC channels for inlets, detectors, or auxiliary gases Pressure may be adjusted by increments of 0.01 psi Atmospheric pressure sensor to compensate for altitude or ambient variation Pressure/flow programming ramps: up to three Inlets and detectors available with EPC on all gas flows (carrier, split vent, makeup, and combustion gases) Carrier and makeup gas settings selectable for He, H 2, N 2, and argon/methane Flow or pressure setpoints on each inlet or detector parameter screen EPC settings included in HP 6890, HP Chemstation, or HP integrator method storage Automated carrier has constant flow, or linear velocity, when capillary column dimensions are entered into the HP 6890 Split/splitless and PTV inlet; flow sensor for control and storage of split ratio Inlet Modules Pressure sensors: ±2% full scale Repeatability: ±0.05psi Temperature coefficient: ±0.01 psi/ C (2 of 5) [21/08/ :57:27]

3 Drift:±0.1 psi/6 months Flow sensors: ±5% depending on carrier gas Repeatability: ±0.35% of setpoint Temperature coefficient: ml/min normalized temperature and pressure (NTP)* per degree Celcius for He or H 2 ; ml/min NTP per degree Celsius for N 2 or Ar/CH 4 Other Specifications Clock time programming Run deviation log (notes any changes to setpoints or expected values during a run, saved with run file in HP ChenStations) Control of eight externalevents (valves, on/off, or low-level contact) Four internal 24-volt connections (up to 150 ma) Two external 24-volt connections (up to 75 ma) Two on/off contact closures (48 V, 250 ma max) Keyboard control of the HP automatic liquid sampler (ALS) Storage of five methods Storage of five ALS sequences Binary coded decimal input for a stream selection valve Context sensitive online help Flame Ionization Detector Range to 450 C Grounded jet and current limited design for operator safety Push button flame ignition Fused silica columns insert within 2 mm of the jet tip Sensitivity: >18 mcoul/gm carbon: nitrogen carrier, in. id jet >15 mcoul/gm carbon: helium carrier, in. id jet >22 mcoul/gm carbon: nitrogen carrier, in. id capillary jet >18 mcoul/gm carbon: helium carrier, 0.01-in. id capillary jet Minimum detectable: <5pg carbon/sec, nitrogen carrier at S/N=2 Linear dynamic range: > *± 10% over a 10 7 range with in. id jet Conditions: column flow 50 ml/min, 45 ml/min H2, 650 ml/min air, propane sample Split/Splitless Capillary Inlet (3 of 5) [21/08/ :57:27]

4 Range to 400C in 1C increments Back-pressure design permits independent adjustment of split flow rate without affecting column flow, 0-30 psi head pressure gauge and regulator standard; 0-15, 0-60, and psi regulators and gauges also available Septum purge built in at 3 ml/min Accepts columns up to 1.2-mm od Accepts 1/4 inch glass column for on-column injection Multimode design includes split and splitless injection Air fan built into mainframe to assist in cool-down of inlet Splitless purge time variable in 0.01-min element Inlets with EPC (Each inlet has the same description as its standard inlet counterpart plus the EPC specifications below) Reproducibility Retention time reproducibility: of n-decane after one blank min standard deviation run and constant ambient temperature Pressure Control Programming: Three ramps, psi/minute Pressure range for inlets: 1-100psi (7-689kPa) digital readout of head pressure or 1-15 psi (7-103 kpa) digital readout of head pressure Flow Range for inlets: Constant Flow Mode (Standard): Inlets Only Maximum Channels: Precision and Accuracy Pressure Setpoint Flow Setpoint ml/min (split/splitless) ml/min (purged-packed and cool on-column Inlet pressure is adjusted real time to maintain constant volumetric flow at column outlet Two inlet channels to control column head pressure Four auziliary channels to control split vent flow (Gas Saver EPC, makeup gas, fuel gases, or external devices general-purpose EPC) psi ml/min. (4 of 5) [21/08/ :57:27]

5 Average Linear Velocity cm/sec. The The Trade Alliance shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. (5 of 5) [21/08/ :57:27]

23 The Thermal Conductivity Detector

23 The Thermal Conductivity Detector 23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing

More information

CHROMOCTANE O N LINE ANALYZER

CHROMOCTANE O N LINE ANALYZER GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines

More information

Agilent 7697A Headspace Sampler Data Sheet

Agilent 7697A Headspace Sampler Data Sheet Agilent 7697A Headspace Sampler Data Sheet Overview The Agilent 7697A Headspace Sampler is part of Agilent s line of gas chromtography products. The 7697A based on the architecture of the market-leading

More information

Clarus 580 Gas Chromatograph

Clarus 580 Gas Chromatograph S P E C I F I C A T I O N S Gas Chromatography Clarus 580 Gas Chromatograph The PerkinElmer Clarus 580 Gas Chromatograph (GC) is a fully automated gas chromatograph. The system offers the capabilities

More information

Standard Test Method for Analysis of Hydrocarbon Waxes by Gas Chromatography EWF METHOD 001/03

Standard Test Method for Analysis of Hydrocarbon Waxes by Gas Chromatography EWF METHOD 001/03 1. Scope Standard Test Method for Analysis of Hydrocarbon Waxes by Gas Chromatography EWF METHOD 001/03 (Version 1 Reviewed 2015) 1. 1 This test method provides for the determination of the carbon number

More information

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax. Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative

More information

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer www.paclp.com Background Biodiesel offers an alternative to fossil diesel fuel & contributes to the reduction

More information

The Determination of Benzene and Toluene in Finished Gasolines Containing Ethanol Using the PerkinElmer Clarus 680 GC with Swafer Technology

The Determination of Benzene and Toluene in Finished Gasolines Containing Ethanol Using the PerkinElmer Clarus 680 GC with Swafer Technology application Note Gas Chromatography Author A. Tipler PerkinElmer, Inc. Shelton, CT 06484 USA The Determination of and in Finished Gasolines Containing Using the PerkinElmer Clarus 680 GC with Swafer Technology

More information

Addressing the World Helium Shortage For Gas Chromatography

Addressing the World Helium Shortage For Gas Chromatography Addressing the World Helium Shortage For Gas Chromatography Helium Conservation and Converting GC Methods to Nitrogen and Hydrogen Carrier Gas James D. McCurry, Ph.D. Senior Scientist Agilent Technologies

More information

GC-2010 Gas Chromatograph INSTRUCTION MANUAL

GC-2010 Gas Chromatograph INSTRUCTION MANUAL 221-40407F Gas Chromatograph INSTRUCTION MANUAL Read this instruction manual thoroughly before using this instrument. Save the manual for future reference. Copyright Shimadzu Corporation 2000. All rights

More information

Operating Manual Volume 3. Detectors. Agilent 6890 Series Gas Chromatograph

Operating Manual Volume 3. Detectors. Agilent 6890 Series Gas Chromatograph Operating Manual Volume 3. Detectors Agilent 6890 Series Gas Chromatograph Agilent Technologies 2000 All rights reserved. Reproduction, adaptation, or translation without permission is prohibited, except

More information

5973 inert Mass Selective Detector

5973 inert Mass Selective Detector 5973 inert Mass Selective Detector Hardware Manual Agilent Technologies 5973 inert Mass Selective Detector Hardware Manual Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Ratio Regulator/ Zero Governor. FRG/6 Series

Ratio Regulator/ Zero Governor. FRG/6 Series Ratio Regulator/ Zero Governor FRG/6 Series CSA Certified ANSI Z21.18 CSA 6.3 CSA Requirement #5.01 Zero Governor and Gas/Air Regulator File # 15406 US and Canadian Models FRG 05/6 FRG 0/6 FRG 10/6 FRG

More information

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...

More information

Agilent Veriflow 500 Electronic Flowmeter. Flow Range: 1 500 sccm. Operation Guide. Agilent Technologies

Agilent Veriflow 500 Electronic Flowmeter. Flow Range: 1 500 sccm. Operation Guide. Agilent Technologies Agilent Veriflow 500 Electronic Flowmeter Flow Range: 1 500 sccm Operation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by

More information

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.

More information

GC Troubleshooting 10. How to use this Troubleshooting Help system... 10. GC Troubleshooting - Top Level... 10 Generic problem descriptions...

GC Troubleshooting 10. How to use this Troubleshooting Help system... 10. GC Troubleshooting - Top Level... 10 Generic problem descriptions... Table of Contents GC Troubleshooting 10 How to use this Troubleshooting Help system... 10 GC Troubleshooting - Top Level... 10 Generic problem descriptions... 11 Baseline related problems... 11 Peak related

More information

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) ACETA.02-1 ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) PRINCIPLE Isovaleraldehyde (IVA) and acetaldehyde are released from the syrup with the aid of dilute phosphoric acid and heat. The liberated

More information

The Electron Capture Detector (ECD)

The Electron Capture Detector (ECD) Theory of operation The ECD is based on the phenomenon that electronegative species can react with thermal electrons present to form negatively charged ions. The loss of such electrons is related to the

More information

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by

More information

C184-E014D GC-2014. Shimadzu Gas Chromatograph System

C184-E014D GC-2014. Shimadzu Gas Chromatograph System C184-E014D GC-2014 Shimadzu Gas Chromatograph System Big Performance & Small Space GC-2014 GC-2014 Shimadzu Gas Chromatograph System High Performance and Expandability Merged at a higher level High Performance

More information

Gas Chromatograph GC Consumables. p/n: 220-94898-02

Gas Chromatograph GC Consumables. p/n: 220-94898-02 Gas Chromatograph GC Consumables p/n: 220-94898-02 Diag. # 1) Septum Nut 2) Needle Guide 3) Septum 4) Injection Port A Assy 5) O-ring for Glass Insert 6) Glass Insert 7) Gold Gasket 8) Capillary Adaptor

More information

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

The Determination of Low Levels of Benzene, Toluene, Ethylbenzene, Xylenes and Styrene in Olive Oil Using a Turbomatrix HS and a Clarus SQ 8 GC/MS

The Determination of Low Levels of Benzene, Toluene, Ethylbenzene, Xylenes and Styrene in Olive Oil Using a Turbomatrix HS and a Clarus SQ 8 GC/MS application Note Gas Chromatography/ Mass Spectrometry Author A. Tipler, Senior Scientist PerkinElmer, Inc. Shelton, CT 06484 USA The Determination of Low Levels of Benzene, Toluene, Ethylbenzene, Xylenes

More information

Agilent 5975 Series MSD

Agilent 5975 Series MSD Agilent 5975 Series MSD Operation Manual Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Agilent Cary 4000/5000/6000i Series UV-Vis-NIR Guaranteed specifications Design overview Double beam, ratio recording, double out-of-plane Littrow monochromator UV-Vis-NIR spectrophotometer (Agilent Cary

More information

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Columns Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Column Selection 93 Features & Benefits of Restek PLOT Columns Features

More information

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# 600000-1621-RFQ)

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# 600000-1621-RFQ) Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) Closing Date and Time: Wednesday, April 13, 2016 at 5:00 p.m. (Pacific Time) Contact: Aaron Galloway Fax: 541-888-3250

More information

Capillary and Packed Gas Chromatograph

Capillary and Packed Gas Chromatograph Capillary and Packed Gas Chromatograph C184-E014G High Performance and Expandability Merged at a higher level Capillary and Packed Gas Chromatograph High Performance Superior Performance Improved design

More information

METHOD 25E - DETERMINATION OF VAPOR PHASE ORGANIC CONCENTRATION IN WASTE SAMPLES. NOTE: Performance of this method should not be

METHOD 25E - DETERMINATION OF VAPOR PHASE ORGANIC CONCENTRATION IN WASTE SAMPLES. NOTE: Performance of this method should not be 1318 METHOD 25E - DETERMINATION OF VAPOR PHASE ORGANIC CONCENTRATION IN WASTE SAMPLES NOTE: Performance of this method should not be attempted by persons unfamiliar with the operation of a flame ionization

More information

On-line Dissolved Gas Analysis

On-line Dissolved Gas Analysis On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully

More information

Micro Cryo-Trap Model 971

Micro Cryo-Trap Model 971 Micro Cryo-Trap Model 971 for Liquid CO2 Cooling Scientific Instrument Services, Inc. 1027 Old York Road Ringoes, NJ 08551 Phone (908) 788-5550 Part #951001M revised 10/ /98 Notice The information in this

More information

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88-1 CE-0087

More information

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2

More information

CORESTA RECOMMENDED METHOD Nº 80

CORESTA RECOMMENDED METHOD Nº 80 CORESTA RECOMMENDED METHOD Nº 80 USE OF THE PART-FILTER METHOD FOR THE ESTIMATION OF SMOKERS EXPOSURE TO NICOTINE AND NICOTINE-FREE DRY PARTICULATE MATTER (January 2016) 0. INTRODUCTION The CORESTA Smoking

More information

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note. EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer HT3 Application Note Introduction The analysis of dissolved gases in ground water is important in

More information

Thermal Conductivity Detector

Thermal Conductivity Detector Thermal Conductivity Detector Troubleshooting Tips The thermal conductivity detector (TCD) detects the difference in thermal conductivity between column effluent flow (carrier gas + sample components)

More information

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: 0000034862. Gaschromategraph GC 5000 BTX Type FID for Benzene

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: 0000034862. Gaschromategraph GC 5000 BTX Type FID for Benzene Umwelt Bundes Amt ror our Environ ment /;;!.. TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000034862 Certified AMS: Manufacturer: Test Institute: Gaschromategraph

More information

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles THERMAL DESORPTION Introduction and Principles Thermal Desorption Thermal desorption is a simple extension of the technique of gas chromatography (GC) It involves the use of heat and a flow of inert gas

More information

Lockout Specification BW Clip Maintenance-free single gas detector

Lockout Specification BW Clip Maintenance-free single gas detector Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than

More information

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE ACTA CHROMATOGRAPHICA, NO. 13, 2003 GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE A. Pavlova and R. Ivanova Refining and Petrochemistry Institute, Analytical Department, Lukoil-Neftochim-Bourgas

More information

430 Power/Electronics Replacement

430 Power/Electronics Replacement Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed

More information

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward Chemical Analysis Natural Gas Analyzer A Family of optimized GC Solutions think forward Gas Chromatography Bruker Natural Gas Analyzers Natural gas is bought and sold as a bulk commodity with price based

More information

Gerstel Field Service Manual Cooled Injection System - CIS4

Gerstel Field Service Manual Cooled Injection System - CIS4 Gerstel Field Service Manual Cooled Injection System - CIS4 CIS 4 Cooled Injection System Field Service Manual 1 Field Service Manual 2 CIS 4 Cooled Injection System Contents list 1. Site Preparation...

More information

Online Infrared Flue Gas Analyzer Gasboard 3000

Online Infrared Flue Gas Analyzer Gasboard 3000 Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume

More information

Gas Custody Transfer Calibration

Gas Custody Transfer Calibration Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform

More information

When your GC/MS is out of Breath

When your GC/MS is out of Breath When your GC/MS is out of Breath Helium and the use of alternative GC carrier gases Lee Marotta, Mike Baylerian, Alan Gallaspy, Andy Tipler, Miles Snow Outline Some background to Helium: where it comes

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Transformer Oil Gas Analysis

Transformer Oil Gas Analysis Get on the Analyzer FAST TRACK Transformer Oil Gas Analysis Helping customers protect the environment! 1 Why Analyzers Value to Customers Alleviates Resource Pressure Facilitates Configuration Use Advanced

More information

WBEA Standard Operating Procedure

WBEA Standard Operating Procedure Page 1 SOP Title Author WBEA Standard Operating Procedure Procedures for operating continuous Total Hydrocarbon (THC) analyzers WBEA-ANA-004-THC Kelly Baragar Implementation date February 19, 2013 Revision

More information

#13 Chromatography is a Gas: An Inquiry-Based Introduction to Gas Chromatography Cynthia N. Peck, Delta College, University Center, MI 48710

#13 Chromatography is a Gas: An Inquiry-Based Introduction to Gas Chromatography Cynthia N. Peck, Delta College, University Center, MI 48710 #13 Chromatography is a Gas: An Inquiry-Based Introduction to Gas Chromatography Cynthia N. Peck, Delta College, University Center, MI 48710 INTRODUCTION To close the yellow note, click once to select

More information

Series. Gas Chromatographs

Series. Gas Chromatographs Series 4060 Gas Chromatographs Series 4060 Overview The Teledyne Analytical Instruments (TAI) Series 4060 speciates gases of interest by combining well-accepted gas chromatography techniques with TAI s

More information

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at

More information

The Use of Hydrogen Carrier Gas for GC/MS

The Use of Hydrogen Carrier Gas for GC/MS Technical Note The Use of Hydrogen Carrier Gas for GC/MS Gas Chromatography/ Mass Spectrometry Highlights Guidelines that can mitigate dangers and leverage benefits of using hydrogen Key safety factors

More information

Process Instrumentation

Process Instrumentation Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A

More information

ADU 5. Automatic Distillation Unit

ADU 5. Automatic Distillation Unit ADU 5 Automatic Distillation Unit Atmospheric Distillation Distillation tests are used to characterize the volatility of petrochemical products. These volatility characteristics are a critical measurement

More information

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent

More information

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Lecture Chromo-3: Gas Chromatography CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder Outline Introduction Instrument overview Carrier gas Sample

More information

Split / Splitless Injection for Capillary GC

Split / Splitless Injection for Capillary GC Split / Splitless Injection for Capillary GC Speakers John V Hinshaw CHROMacademy GC Dean GC Connections editor Moderator Tony Taylor CHROMacademy Trainer Technical Director, Crawford Scientific Dave Walsh

More information

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital

More information

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance AC DHA Solutions Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils ASTM D 5134, D 6729, D 6730, D 6733 Compliance Signal Alignment Automated with LineUp TM Tool Compatible

More information

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources

More information

Gas Chromatography Liner Selection Guide

Gas Chromatography Liner Selection Guide Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing

More information

C ons u ma ble s. Shimadzu Gas Chromatography

C ons u ma ble s. Shimadzu Gas Chromatography AO C - 2 0 i Au toi n j e c t o r & AO C - 2 0 S A u t o s a m p l e r C ons u ma ble s Shimadzu Gas Chromatography Description Part No. Qty Plug type Septa, for all Models of GC and all Injection Ports

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

TECHNICAL SPECIFICATION TYPE ATESO ALFA

TECHNICAL SPECIFICATION TYPE ATESO ALFA Page: 1 of 5 TECHNICAL SPECIFICATION TYPE ATESO ALFA 1. GENERAL 1.1. Make (trade name of manufacturer): BRANO a.s. 1.2. Type and general commercial description(s): ATESO ALFA 1.2.1 1.2.2. Variants: Versions:

More information

Chemical Analysis. Simulated Distillation Analyzers. A full range of simulated Distillation Analysis Solution. Gas Chromatography.

Chemical Analysis. Simulated Distillation Analyzers. A full range of simulated Distillation Analysis Solution. Gas Chromatography. Chemical Analysis Simulated Distillation Analyzers A full range of simulated Distillation Analysis Solution think forward Gas Chromatography Bruker Simulated Distillation Analyzers Bruker s range of Simulated

More information

Expectations for GC-MS Lab

Expectations for GC-MS Lab Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the two weeks, I expect that you will

More information

BTI Light commercial atmospheric water heater

BTI Light commercial atmospheric water heater Light commercial atmospheric water heater BTI - 65/85/100 Atmospheric water heater, primarily intended for light commercial / industrial applications Control, high limit and energy cut-off thermostats

More information

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water Sjaak de Koning 1, Mark van Lieshout 2, Hans-Gerd Janssen 2 and Wil van Egmond 1 1 ATAS, De Run 4334, PO Box

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Siemens BACnet Terminal Box (VAV) Controller

Siemens BACnet Terminal Box (VAV) Controller Technical Specification Sheet Document. 149-810 May 30, 2012 Siemens BACnet Terminal Box (VAV) Controller The Siemens BACnet Terminal Box (VAV) Controller provides high performance direct digital control

More information

NI 6585 Specifications

NI 6585 Specifications NI 6585 Specifications This document lists the specifications of the National Instruments 6585 FlexRIO low-voltage differential (LVDS) adapter module. Pair these specifications with your FPGA module specifications.

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

Conversion of Agilent EI GC/MSD Systems To Hydrogen Carrier Gas. Agilent Technologies

Conversion of Agilent EI GC/MSD Systems To Hydrogen Carrier Gas. Agilent Technologies Conversion of Agilent EI GC/MSD Systems To Hydrogen Carrier Gas Agilent Technologies 1 Introduction: Converting From He To H 2 Many GC/MS users are considering changing from helium to hydrogen carrier

More information

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts; 1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2

More information

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and

More information

For over 40 years, the leader in. nitrous oxide. equipment technology.

For over 40 years, the leader in. nitrous oxide. equipment technology. Conscious Sedation Delivery Systems For over 40 years, the leader in nitrous oxide equipment technology. Made in U.S.A. Over 40 years ago Fraser Sweatman pioneered the technology used for safe delivery

More information

SCION SQ Series GC-MS

SCION SQ Series GC-MS SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,

More information

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana* Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana* a Department of Pharmaceutical Analysis, Andhra University, Visakhapatnam. b Department of Pharmaceutics,

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

Mitos P-Pump. product datasheet

Mitos P-Pump. product datasheet product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump

More information

Nortrax 23 52 23 190 David Manchester Road, Ottawa FAN ASSISTED COPPER TUBE BOILERS 21 May 2014 Project: 13-104-070 PART 1 - GENERAL...

Nortrax 23 52 23 190 David Manchester Road, Ottawa FAN ASSISTED COPPER TUBE BOILERS 21 May 2014 Project: 13-104-070 PART 1 - GENERAL... 21 May 2014 PART 1 - GENERAL... 1 1.1. WORK INCLUDED... 1 1.2. QUALITY ASSURANCE... 1 1.3. APPROVALS... 1 PART 2 - PRODUCTS... 1 2.1. HEATING BOILERS... 1 2.2. BOILER SEQUENCE CONTROL... Error! Bookmark

More information

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities Device Charts For Oil and Gas Handling and Production Facilities Purpose/Scope: The purpose of this document is to provide standardized guidance for use by the regulated community and air permit reviewers,

More information

Hydrogen as an alternative to Helium for gas chromatography.

Hydrogen as an alternative to Helium for gas chromatography. Application Note Gas Chromatography. Application Note for Specialty Gases. as an alternative to for gas chromatography. Author: Peter Adam Linde AG, Linde Gas Division Seitnerstrasse 70, 82049 Pullach,

More information

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS AppNote 10/2012 Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages T. Albinus, K. MacNamara Gerstel GmbH & Co. KG, Eberhard-Gerstel-Platz

More information

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) 1 Fast Analysis of C1 to C8 hydrocarbons for mud logging applications within 2 minutes using a temperature programmable Micro GC Fusion NEN GAS2015 Debbie

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

3500/62 Process Variable Monitor

3500/62 Process Variable Monitor 3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

NI USB-5681 RF Power Meter Specifications

NI USB-5681 RF Power Meter Specifications NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour

More information