Report No.: 9A070801C2 Page 1 of 30. Test Report EN : 2006
|
|
- Eugene Singleton
- 7 years ago
- Views:
Transcription
1
2
3 Report No.: 9A070801C2 Page 1 of 30 EN : 2006 Product: Ethernet Device Switch Trade Name: MOXA Model Number: EDS-619-X1; EDS-616-X1 (X1=0-9, A-Z or blank) Prepared for MOXA Inc. Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C. TEL.: FAX.: Prepared by 244 No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei County, Taiwan, R.O.C. TEL.: FAX.: Remark: The test report consists of 30 pages in total. It shall not be reproduced except in full, without the written approval of IETC. This document may be altered or revised by IETC only, and shall be noted in the revision section of the document. The test results in the report only to the tested sample.
4 Report No.: 9A070801C2 Page 2 of 30 Table of Contents 1 General Information Description of Equipment Under Test Fast Ethernet Modules Summary of Test Results Details of Tested Supporting System Test Facility Measurement Uncertainty Measured Mode Configuration of EUT Setup Test Step of EUT 11 2 Power Line Conducted Emission Instrument Test Requirement Test Procedures Test Result 12 3 Radiated emission Instrument Test Requirement Test Procedures Test Result 15 4 Performance Criterion of Immunity Test EN Electrostatic Discharge Test Instrument Test Requirement Test Procedures Test Result 19 6 Radio- Frequency, Electromagnetic Field Immunity Test Instrument Test Requirement Test Procedures Test Result 20
5 Report No.: 9A070801C2 Page 3 of 30 7 Transient Burst Susceptibility Test Instrument Test Requirement Test Procedures Test Result 21 8 Surges Test Instrument Test Requirement Test Procedures Test Result 22 9 Radio- Frequency, Conducted Disturbances Immunity Test Instrument Test Requirement Test Procedures Test Result Power Frequency Magnetic Field Immunity Test Instrument Test Requirement Test Procedures Test Result Pulsed magnetic field Immunity Test Instrument Test Requirement Test Procedures Test Result Photographs of Test Power Line Conducted Emission Measurement Radiated Emission Measurement Electrostatic Discharge Test Point Photographs of EUT 29
6
7 Report No.: 9A070801C2 Page 5 of 30 1 General Information 1.1 Description of Equipment Under Test Product Model Number Applicant Manufacturer : Ethernet Device Switch Date of Receipt of Sample : Jul. 08, 2009 : EDS-619-X1; EDS-616-X1 (X1=0-9, A-Z or blank) : MOXA Inc. Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C. : MOXA Inc. Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C. Date of Test : Jul. 14 ~ 27, 2009 Power Supply : Input: 9.6~60VDC, 0.4A Power cord: Non-shielded Detachable, 1.5 m w/o core Additional Description : 1.) The EUT is Ethernet Device Switch. 2.) The Model Number EDS-619-T is representative selected in the test and included in this report. 3.) All model included in this report, the difference detail as follows: Model Number EDS-619-X1 EDS-616-X1 Fiber (RX & TX) Port 16 RS232 Console Port 1 Power Port 2 SFP & RJ45 (G1, G2, G3) Gigabit Port 3 0 X1=0-9, A-Z or blank (for marketing purpose) 4.) For more detail specification about EUT, please refer to the user s manual.
8 Report No.: 9A070801C2 Page 6 of Fast Ethernet Modules Model No. CM-600-4TX CM-600-4MSC CM-600-4MST CM-600-4SSC CM-600-2MSC/2TX CM-600-2MST/2TX CM-600-2SSC/2TX CM-600-3MSC/1TX CM-600-3MST/1TX CM-600-3SSC/1TX CM-600-4TX-RT CM-600-4TX-BP Description Fast Ethernet interface module with 4 10/100BaseT(X) ports Fast Ethernet interface module with 4 100BaseFX multi-mode ports (SC connectors) Fast Ethernet interface module with 4 100BaseFX multi-mode ports (ST connectors) Fast Ethernet interface module with 4 100BaseFX single-mode ports (SC connectors) Fast Ethernet interface module with 2 10/100BaseT(X) ports and 2 100BaseFX multi-mode ports (SC connectors) Fast Ethernet interface module with 2 10/100BaseT(X) ports and 2 100BaseFX multi-mode ports (ST connectors) Fast Ethernet interface module with 2 10/100BaseT(X) ports and 2 100BaseFX single-mode ports (SC connectors) Fast Ethernet interface module with 1 10/100BaseT(X) ports and 3 100BaseFX multi-mode ports (SC connectors) Fast Ethernet interface module with 1 10/100BaseT(X) ports and 3 100BaseFX multi-mode ports (ST connectors) Fast Ethernet interface module with 1 10/100BaseT(X) ports and 3 100BaseFX single-mode ports (SC connectors) Fast Ethernet Interface Module with 4 10/100BaseT(X) ports (IEEE1588 PTP) Fast Ethernet Interface Module with 4 10/100BaseT(X) ports (Bypass)
9 Report No.: 9A070801C2 Page 7 of Summary of Test Results Report Clause Phenomenon EN Reference Clause(s) 2 Power Line Conducted Emission 5 3 Radiated Emission 5 Reference standard EN CISPR CISPR EN CISPR Result Applicable Applicable 5 Electrostatic Discharge 6 EN Applicable 6 Radio- Frequency, Electromagnetic Field 6 EN Applicable 7 Transient Burst Susceptibility 6 EN Applicable 8 Surges 6 EN Applicable 9 Radio- Frequency, Conducted Disturbances 6 EN Applicable 10 Power frequency magnetic field 6 EN Applicable 11 Pulsed magnetic field 6 EN Applicable
10 Report No.: 9A070801C2 Page 8 of Details of Tested Supporting System Link PC PC16 Model Number : IBM ThinkCentre 8175-i51 Serial Number : 99NDRP6 CPU Speed : Pentium 4 Celeron D 2.66GHz EMC Compliance : CE, FCC, C-Tick, UL, BSMI: R33026 Manufacturer : IBM RAM : 256M*1 Hard Disk Driver : 40GB PC23 Model Number : ASUS-M500 CPU Speed : Intel Celeron 430 EMC Compliance : BSMI R31018 Manufacturer : ASUS RAM : Nanya 1G DDR2 800 Hard Disk Driver : Seagate ST380815AS 80G Switching Power Supply : Detal GPS-300AB C 300W Power Cord : Non-shielded, Detachable, 1.8m, w/o core DC Source Model Number : GPC-6030D Serial Number : C Manufacturer : INSTEK AC Power Cord : Non-shielded, Detachable, 1.8m, without core Output Data Cable : Non-shielded, Detachable, 1m, without core Cable Fiber Cable *8 : Non-Shielded, Detachable, 2.3m, w/o core Fiber Cable *8 : Non-Shielded, Detachable, 1.2m, w/o core RS232 Console Cable *1 : Non-Shielded, Detachable, 2m, w/o core LAN Cable *2 : Non-Shielded, Detachable, 4m, w/o core
11 Report No.: 9A070801C2 Page 9 of Test Facility Site Description : Conduction 1 OATS 1 EMS Site Name of Firm : Company web : Site 1, 2 Location : No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei County, Taiwan, R.O.C. Site 3, 4 Location : No. 12, Ruei-Shu Valley, Ruei-Ping Tsun, Lin-Kou Hsiang, Taipei County, Taiwan, R.O.C. Site Filing : Federal Communication Commissions USA Registration No.: (OATS 1 & 2) Registration No.: (OATS 3 & 4) Designation No.: TW1020 Voluntary Control Council for Interference by Information Technology Equipment (VCCI) Japan Member No.: 1349 Registration No. (Conducted Room): C-1094 Registration No. (Conducted Room): T-1562 Registration No. (OATS 1): R-1040 Registration No. (OATS 2): R-1041 Industry Canada (IC) OUR FILE: Submission: Registration No. (OATS 1): 4437A-1 Registration No. (OATS 2): 4437A-2 Registration No. (OATS 3): 4437A-3 Registration No. (OATS 4): 4437A-4 Japan Electrical Safety & Environment Technology Laboratories (JET) Registration No.: 04S03-01 Site Accreditation : Bureau of Standards and Metrology and Inspection (BSMI) Taiwan, R.O.C. Accreditation No.: SL2-IN-E-0026 for CNS13438 / CISPR22 SL2-R1-E-0026 for CNS13439 / CISPR13 SL2-R2-E-0026 for CNS13439 / CISPR13 SL2-A1-E-0026 for CNS / CISPR14-1 Taiwan Accreditation Foundation (TAF) Accreditation No.: 1113 TüV NORD Certificate No: TNTW0801R-01
12 Report No.: 9A070801C2 Page 10 of Measurement Uncertainty No. Item Value 1 Power Line Conducted Emission (Conduction 1) 2.40 db 2 Power Line Conducted Emission (Conduction 2) 2.40 db 3 Disturbance Power Emission (Conduction 2) 3.10 db 4 Click disturbances Emission (Conduction 2) 2.40 db 5 Radiated Electromagnetic disturbance (Loop Antenna) 4.80 db 6 Radiated Emission Test (OATS 1) 3.14 db 7 Radiated Emission Test (OATS 2) 3.14 db 8 Radiated Emission Test (OATS 3) 3.14 db 9 Radiated Emission Test (OATS 4) 3.14 db 10 Radiated Emission Test (1GHz~18GHz) 3.20 db 11 Radiated Emission Test (18GHz~40GHz) 3.40 db
13 Report No.: 9A070801C2 Page 11 of Measured Mode The test mode for final test is as follows: Mode 1: LAN Mode (EDS-619-T) For Telecommunication Ports Conducted Emission Measurement: Mode 1: LAN Mode (10 Mbps) (EDS-619-T) Mode 2: LAN Mode (100 Mbps) (EDS-619-T) Mode 3: LAN Mode (1 Gbps) (EDS-619-T) 1.8 Configuration of EUT Setup Link PC Link PC LAN Cable LAN Cable Fiber terminal DC Source RJ45 terminal RS232 Console Cable Floating 1.9 Test Step of EUT Setup the EUT and peripheral as above Execute power on of EUT and link with peripheral PC Executed the test.
14 Report No.: 9A070801C2 Page 12 of 30 2 Power Line Conducted Emission 2.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date EMI Test Receiver Rohde & Schwarz ESCS / /08/19 Pulse Limiter Rohde & Schwarz ESH3-Z / /09/08 RF Cable HARBOUR RG400 CBL /03/16 L.I.S.N. Schaffner MN2050D /06/22 L.I.S.N. Rohde & Schwarz ESH3-Z /02/18 Note: The above equipments are within the valid calibration period. 2.2 Test Requirement Reference to EN clause 5 and EN table 1 Frequency (MHz) Q.P. (Quasi-Peak) A.V. (Average) 0.15 ~ ~ ~ Test Procedures Reference to CISPR clause and CISPR clause Test Result PASS. The final test data is shown as following pages.
15 Report No.: 9A070801C2 Page 13 of 30 Power Line Conducted Test Data EUT: Ethernet Device Switch CLIENT: MOXA MODEL: EDS-619-T RATING: DC 24V Temperature: 27.0 Humidity: 68 % POLARITY: Line DISTANCE: Serial No.: FILE/DATA#: MOXA.emi/762 OPERATOR: Terry TEST SITE: Conduction1 Frequency Factor Meter Reading (dbµv) Emission Level (dbµv) Limits (dbµv) Margin (db) (MHz) (db) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Remark: 1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss. Test Mode: Mode 1: LAN Mode (EDS-619-T)
16 Report No.: 9A070801C2 Page 14 of 30 Power Line Conducted Test Data EUT: Ethernet Device Switch CLIENT: MOXA MODEL: EDS-619-T RATING: DC 24V Temperature: 27.0 Humidity: 68 % POLARITY: Neutral DISTANCE: Serial No.: FILE/DATA#: MOXA.emi/763 OPERATOR: Terry TEST SITE: Conduction1 Frequency Factor Meter Reading (dbµv) Emission Level (dbµv) Limits (dbµv) Margin (db) (MHz) (db) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Remark: 1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss. Test Mode: Mode 1: LAN Mode (EDS-619-T)
17 Report No.: 9A070801C2 Page 15 of 30 3 Radiated emission 3.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date EMI Test Receiver Rohde & Schwarz ESCS /09/10 Bilog Antenna Schaffner CBL6111c /02/22 Pre-Amplifier Agilent 8447D 1937A /12/08 RF Cable IETC CBL15 CBL /11/18 Note: The above equipments are within the valid calibration period. 3.2 Test Requirement Reference to EN clause 5 and EN table 1 Quasi-Peak Frequency (MHz) db(µv/m) 3.3 Test Procedures 30 ~ ~ Reference to CISPR Test Result PASS. The final test data is shown as following pages.
18 Report No.: 9A070801C2 Page 16 of 30 Radiated Emission Measurement Data EUT: Ethernet Device Switch CLIENT: MOXA MODEL: EDS-619-T RATING: DC 24V Temperature: 30.0 Humidity: 46 % POLARITY: Horizontal DISTANCE: 10 m Serial No.: FILE/DATA#: MOXA.emi/115 OPERATOR: John TEST SITE: OATS1 Frequency Factor Meter Reading Emission Level Limits Margin (MHz) (db) (dbµv) (dbµv/m) (dbµv/m) (db) ** ** ** ** ** ** ** ** ** Remark: 1. * Mark means readings are Peak Values. 2. ** Mark means readings are Quasi-Peak values. 3. Factor = Antenna Factor + Cable Loss Pre-amplifier. Test Mode: Mode 1: LAN Mode (EDS-619-T)
19 Report No.: 9A070801C2 Page 17 of 30 Radiated Emission Measurement Data EUT: Ethernet Device Switch CLIENT: MOXA MODEL: EDS-619-T RATING: DC 24V Temperature: 30.0 Humidity: 46 % POLARITY: Vertical DISTANCE: 10 m Serial No.: FILE/DATA#: MOXA.emi/114 OPERATOR: John TEST SITE: OATS1 Frequency Factor Meter Reading Emission Level Limits Margin (MHz) (db) (dbµv) (dbµv/m) (dbµv/m) (db) ** ** ** ** ** ** ** ** ** ** Remark: 1. * Mark means readings are Peak Values. 2. ** Mark means readings are Quasi-Peak values. 3. Factor = Antenna Factor + Cable Loss Pre-amplifier. Test Mode: Mode 1: LAN Mode (EDS-619-T)
20 Report No.: 9A070801C2 Page 18 of 30 4 Performance Criterion of Immunity Test 4.1 EN Criterion A B C Description The apparatus shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls.
21 Report No.: 9A070801C2 Page 19 of 30 5 Electrostatic Discharge Test 5.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date ESD Simulator EMC PARTNER ESD /10/19 Note: The above equipments are within the valid calibration period. 5.2 Test Requirement Reference to EN clause 6 Air discharge: ±8 KV Contact discharge: ±6 kv Indirect discharge: ±6 kv Performance criterion: B 5.3 Test Procedures Reference to IEC clause Test Result Temperature: 25.0 ; Humidity: 48 %; Atm pres: 101 Kpa; Test Engineer: Nigel PASS. The performance criterion after tested EN : Air discharge ±2 kv, ±4 kv, ±8 kv: A B C Contact discharge ±2 kv, ±4 kv, ±6 kv: A B C Indirect discharge (HCP) ±2 kv, ±4 kv, ±6 kv: A B C Indirect discharge (VCP Front, Left, Back, Right) ±2 kv, ±4 kv, ±6 kv: A B C
22 Report No.: 9A070801C2 Page 20 of 30 6 Radio- Frequency, Electromagnetic Field Immunity Test 6.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date RF Power Amplifier Frankonia FLG-200B 1038 N. C. R RF Power Amplifier Frankonia FLG-50C 1013 N. C. R Directional Coupler Werlatone C N. C. R Directional Coupler Werlatone C N. C. R Bilog Antenna Frankonia BTA-M 06012M N. C. R Signal Generator R&S SM /10/14 RF Power Meter Dr.Hubert GmbH PMS_ A /11/03 Electric Field Probe Narda 2244/90.21 BF /11/06 Field-strength-meter Narda EMR-20 BC /11/06 Note: The above equipments are within the valid calibration period. 6.2 Test Requirement Reference to EN clause 6 The frequency steps: 1%, Log sweep, Dwell time: 3.0 sec. Frequency range: 80 to 1000 MHz, Field strength: 20 V/m, 80% AM (1kHz), (Note: For equipment mounted in network communication center a severity level of 10V/m may be used.) Frequency range: 1400 to 2100 MHz, Field strength: 10 V/m, 80% AM (1kHz), Frequency range: 2100 to 2500 MHz, Field strength: 5 V/m, 80% AM (1kHz), Performance criterion: A 6.3 Test Procedures Reference to IEC clause Test Result Temperature: 26.0 ; Humidity: 58 %; Atm pres: 101 Kpa; Test Engineer: Nigel PASS. The performance criterion after tested EN : Frequency range: 80 to 1000 MHz, Field strength: 20 V/m, 80% AM (1kHz), Performance criterion: A B C Frequency range: 1400 to 2100 MHz, Field strength: 10 V/m, 80% AM (1kHz), Performance criterion: A B C Frequency range: 2100 to 2700 MHz, Field strength: 5 V/m, 80% AM (1kHz), Performance criterion: A B C
23 Report No.: 9A070801C2 Page 21 of 30 7 Transient Burst Susceptibility Test 7.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date EMC Pro System KeyTek EMC Pro /03/16 EFT Clamp KeyTek PRO-CCL-C N. C. R. Note: The above equipments are within the valid calibration period. 7.2 Test Requirement Reference to EN clause 6 5 khz Repetition frequency ±2.0 kv input AC power ports. ±2.0 kv input DC power ports. ±2.0 kv for Signal ports. Performance criterion: A 7.3 Test Procedures Reference to IEC clause Test Result Temperature: 25.0 ; Humidity: 48 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN : ±2.0 kv input DC power port: Line + Neutral + PE Performance criterion: A B C ±2.0 kv Signal port: RJ45 Performance criterion: A B C
24 Report No.: 9A070801C2 Page 22 of 30 8 Surges Test 8.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date EMC Pro Systems KeyTek EMC Pro /03/15 Surge Telecom Box KeyTek CM-TELCD N. C. R. Note: The above equipments are within the valid calibration period. 8.2 Test Requirement Reference to EN clause 6 Input AC power ports: Line to Neutral: ±1kV (peak), 1.2/50 us, 42Ω, 0.5µF Line (Neutral) to earth: ±2kV (peak), 1.2/50 us, 42Ω, 0.5µF Input DC power ports: Line to Neutral: ±1kV (peak), 1.2/50 us, 42Ω, 0.5µF Line (Neutral) to earth: ±2kV (peak), 1.2/50 us, 42Ω, 0.5µF Signal and telecommunication ports: ±2kV(peak): 1.2/50 us, 42Ω, 0.5µF Performance criterion: B 8.3 Test Procedures Reference to IEC clause Test Result Temperature: 25.0 ; Humidity: 55 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN : ±0.5 kv (peak) Input DC power port: Line to line Performance criterion: A B C ±1.0 kv (peak) Input DC power port: Line to line Performance criterion: A B C ±0.5 kv (peak) Input DC power port: Line to earth (ground) Performance criterion: A B C ±1.0 kv (peak) Input DC power port: Line to earth (ground) Performance criterion: A B C ±2.0 kv (peak) Input DC power port: Line to earth (ground) Performance criterion: A B C ±2.0 kv (peak) Signal port: RJ45 Performance criterion: A B C
25 Report No.: 9A070801C2 Page 23 of 30 9 Radio- Frequency, Conducted Disturbances Immunity Test 9.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date Signal Generator R&S SMY / /07/20 Power Amplifier Frankonia CIT D1278 N. C. R. Coupler WERLATONE C N. C. R. Attenuator SCHAFFNER ATN N. C. R. M3 C.D.N FCC FCC-801-M3-25A 2045 N. C. R. M2 C.D.N SCHAFFNER M N. C. R. EM-CLAMP SCHAFFNER KEMZ N. C. R. Note: The above equipments are within the valid calibration period. 9.2 Test Requirement Reference to EN clause 6 Frequency range: 0.15 to 80 MHz, Field strength: 10 V, 80% AM (1kHz) Input AC power ports. Input DC power ports. Signal and telecommunication ports. Performance criterion: A 9.3 Test Procedures Reference to EN clause Test Result Temperature: 25.0 ; Humidity: 56 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN : Frequency range: 0.15 to 80 MHz, Field strength: 10 V, 80% AM (1kHz), Input DC power port. Performance criterion: A B C Signal and telecommunication port. Performance criterion: A B C
26 Report No.: 9A070801C2 Page 24 of Power Frequency Magnetic Field Immunity Test 10.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date Magnetic field generator PMM PMM J /09/04 Note: The above equipments are within the valid calibration period Test Requirement Reference to EN clause 6 AC Systems (100A/m) Power Frequency: 16.7Hz Power Frequency: 50Hz Power Frequency: DC 0Hz DC Systems (300A/m) Power Frequency: 16.7Hz Power Frequency: 50Hz Power Frequency: DC 0Hz Performance criterion: A Note: Test only applies to apparatus containing devices sensitive to magnetic fields e.g. Hall elements, electro-dynamic microphones etc Test Procedures Reference to EN clause Test Result Temperature: 25.0 ; Humidity: 55 %; Atm pres: 101 Kpa; Test Engineer: Nigel PASS. The performance criterion after tested EN : DC Systems: 300 A/m Performance criterion: A B C DC Systems: 1000 A/m (short duration: 3 sec) Performance criterion: A B C
27 Report No.: 9A070801C2 Page 25 of Pulsed magnetic field Immunity Test 11.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date Magnetic field generator PMM PMM J /09/04 Note: The above equipments are within the valid calibration period Test Requirement Reference to EN clause 6 Pulsed magnetic field: 300 A/m Performance criterion: B 11.3 Test Procedures Reference to EN clause Test Result Temperature: 25.0 ; Humidity: 55 %; Atm pres: 101 Kpa; Test Engineer: Nigel PASS. The performance criterion after tested EN : Pulsed magnetic field: 300 A/m Performance criterion: A B C
28 Report No.: 9A070801C2 Page 26 of Photographs of Test 12.1 Power Line Conducted Emission Measurement Front View Rear View
29 Report No.: 9A070801C2 Page 27 of Radiated Emission Measurement Front View Rear View
30 Report No.: 9A070801C2 Page 28 of Electrostatic Discharge Test Point View of Discharge Point-1 (Green: Air discharge; Red: Contact discharge) View of Discharge Point-2 (Red: Contact discharge)
31 Report No.: 9A070801C2 Page 29 of Photographs of EUT Front View of EUT Rear View of EUT
32 Report No.: 9A070801C2 Page 30 of 30 I/O Port
Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820
Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)
More informationRated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
More informationEN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5
EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA
More informationTEST REPORT EN 55014-2 (1997) +A1 (2001)
Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....
More informationEMC TEST REPORT For. Webcam. Model Number: CAM67U
EMC TEST REPORT For Webcam Model Number: CAM67U Prepared for : Gembird Europe B.V. Wittevrouwen 56, 1358CD Almere, The Netherlands. Phone: +31-36-5211588 Prepared By : Shenzhen Meihua Electronic Technology
More informationPrepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.
www.ecmg-global.com EMC TEST REPORT On Model Name: DL-P40 Computer Control System Model Number: Release 3.0 Hardware and Software Brand Name: Dorman Long Technology Ltd. Trade Mark: DLT Prepared for Dorman
More informationTest Report #: 1981-3 Date: April 8, 2005
Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model
More informationSHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT
Shenzhen BST Technology Co., Ltd. SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT Prepared For : Product Name: Model : Prepared By : SHENZHEN GEMBIRD ELECTRONICS LTD 5th Floor, Building B, Shifeng Industry
More informationFCC PART 15B CLASS A MEASUREMENT AND TEST REPORT
FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT For SAMBO HI TECH CO., LTD. 616-15, GANSUK4-DONG, NAMDONG-GU, INCHUN 405-810, KOREA Model: LSR700, SCI545HV1EF, SCI545HVEF This Report Concerns: Original
More informationMYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2
MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2 EN55024 (1998), EN61000-3-2 (2001), EN61000-3-3 (1995 W/A1: 98), EN55022 (1998) CLASS A, CISPR 22 (1997) CLASS A & FCC PART 15 SUBPART
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SND6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationMYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING
TESTING CERT #803.01, 803.02, 803.05, 803.06 MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS 15.107 AND 15.109 CLASS A TESTING DATE OF
More informationEMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20
EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan
More informationElectromagnetic Compatibility Test Report Test results of Floww equipment
Electromagnetic Compatibility Test Report Test results of Floww equipment Reference number Status test report Brand Model number : 10C00357RPT01.doc : Final : Floww : mobilefloww screenfloww pocketfloww
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment Brand Name /Trade Mark Type designation /model Applicant Network Camera SAMSUNG SND-5083P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives
More informationStandard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter
Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SNP-5300P SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationCERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)
CERTIFICATE Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03 This is to certify that the following designated product Product Trade name Model Number : 1 Port Device Server : Moxa : NPort 5150(-T),
More informationVariant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.
EMC TEST REPORT Project No. LBE091881 Revision No. NONE Name of organization Samsung Electronics Co., Ltd. Applicant Address 416 Maetan 3-Dong,Yeongtong-Gu,Suwon-Si, Gyeonggi-Do, 443-742 Korea Date of
More informationEMC TEST REPORT. Page: 1 of 38. Reference No.: WT08010091-S-E
Page: 1 of 38 EMC TEST REPORT Reference No. Applicant Address : WT08010091-S-E : Gembird Electronics Ltd. : Room 1709 A, News Building, #2 Shennan Zhong Lu, Shenzhen, China Equipment Under Test (EUT) :
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNP-6200RHP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Camera SAMSUNG SNO-6011RP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationRAPPORTO DI PROVA / TEST REPORT
RAPPORTO DI PROVA / TEST REPORT Rif./Ref.No. FCCTR_130738-0 Data / Date: 17/09/2013 Pagine / Pages : 15 Scopo delle prove /Test object : Richiedente / Applicant : Persona di riferimento / Applicant s referee
More informationEMC Test for Compliance with EU EMC Directive 2004/108/EU
EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods
More informationSGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
588 West Jindu Road,Songjiang District,Shanghai,China Telephone: +86 (0) 21 6191 5666 Fax: +86 (0) 21 6191 5678 ee.shanghai@sgs.com Page: 1 of 23 1 Cover Page Application No.: Applicant: Manufacturer:
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010
ELECTROMAGNETIC COMPATIBILITY TEST Report reference N R-255 EMC 2010 Constructor. Address Reference person. C LUCE S.r.l. Via Marmolada 5/11 20060 Truccazzano (MI) Italy ---- Product....... Model......
More informationIndustrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
More informationTEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.
198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological Development District, Guangzhou, China 510663 Telephone: +86 (0) 20 82155555 Fax: +86 (0) 20 82075059 Email: sgs_internet_operations@sgs.com
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationMeasurement of RF Emissions from a Final Coat Electronics Corrosion Module
Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA
More informationFCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT
FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT For AeroComm, Inc. 10981 Eicher Drive Lenexa, KS 66219 2003-05-22 This Report Concerns: Original Report Equipment Type: 900MHz Transceiver Test Engineer:
More informationReport No. 091028R-RFCEP02V01. Test Report. MS-6633, VS12489, NetOn AP1900. Transmitter Module. MSI / MS-6894
Test Report Product Name All in one PC Model No. Transmitter Module. MSI / MS-6894 MS-6633, VS12489, NetOn AP1900 Applicant Address MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien,
More informationLAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium
LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps
More informationTEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio
TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),
More informationDATA SHEET DVI - HDCP Extension Cable
DATA SHEET DVI - HDCP Extension Cable Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications
More informationXPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series
More informationBioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date
Test Report for CE Report Number Applicant ESTCE0803-003 Company Name Address Product type Suprema Inc. 16F Parkview Office Tower, Jeongja-dong, Bundang-gu,Seongnam, Gyeonggi, 463-863 Korea FINGERPRINT
More informationElectromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613
Report No.: 0000091428 31160742.001 Page 1 of 36 Electromagnetic Compatibility Test Report Prepared in accordance with EN 55022: 2006, +A1: 2007 On DC DC umodule Regulator LTM4613 For Linear Technology
More informationEMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.
EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory
More informationAgilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
More informationPE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface
More informationRoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
More informationFoxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
More informationEDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions
EDR-G903 Series Industrial Gigabit Firewall/VPN secure router Router/Firewall/VPN* all-in-one High performance Gigabit copper/fiber combo port WAN redundancy function with 2 WAN interfaces and 1 LAN interface
More informationORION TELECOM NETWORKS INC. T1
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240,
More informationApplication. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
More informationReport No. 106262R-RFCEP76V01-A. Test Report. Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420. Date of Receipt June 15, 2010
Test Report Product Name All in one PC Model No. MS-AE12, AE2420 3D, MS-AE31 3D, MS-AE31, AE2420 Applicant MICRO-STAR INT'L Co., LTD. Address No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.
More informationMoxa PoE Media Converter
Moxa PoE Media Converter IMC-P101 Hardware Installation Guide First Edition, November 2009 2009 Moxa Inc. ll rights reserved. Reproduction without permission is prohibited. Fl.4, No.135, Lane 235, Pao-Chiao
More informationFor the following information
For the following information Product : Motherboard Model Number : M5A78L-M/USB3 Brand : ASUS Ref. File No.: C1M1104201 Applicant : ASUSTEK Computer Inc. Manufacturer #1 : MainTek Computer (Suzhou) Co.,
More informationTEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement
TEST REPORT Applicant Address Shenzhen Gembird Electronics Ltd. 5F, Building B, Shi-Feng Industrial Zone, Hua-Ning Rd., Xin-Wei Village, Da-Lang Street, Long-Hua, Bao-An Area, Shenzhen 518109, Guangdong
More informationMoxa EtherDevice Switch
Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The
More informationDeclaration of Conformity.
Declaration of Conformity. 음 Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Digital Video Recorder SAMSUNG SRD-1656DP SAMSUNG TECHWIN CO., LTD. In accordance with the following
More informationTest result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC 1106180 File reference No: 2011-07-18
Report No: FCC 1106180 File reference No: 2011-07-18 ISO/IEC17025Accredited Lab. Applicant: FUJIAN NAN AN BAOFENG ELECTRONICS CO., LTD Product: Model No: Trademark: Two Way Radio UV-3R BAOFENG Test Standards:
More informationCommunicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
More informationRADIO TEST REPORT. EN 300 440-2 SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL-12092-01-01
RADIO TEST REPORT SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range Report Reference No.... : G0M-1206-2043-TEU440G-V01 Testing Laboratory... : Eurofins Product Service GmbH Address...
More informationReport No. 099096R-RFCEP76V01. Test Report. Product Name All in one PC Model No. MS-6657,AE2220 Transmitter Module Realtek / RTL8191SE
Test Report Product Name All in one PC Model No. MS-6657,AE2220 Transmitter Module Realtek / RTL8191SE Applicant MICRO-STAR INT L Co., LTD. Address No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan,
More informationCE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.
EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD. CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN14040316E-E01 Phone: +86-755-83585700 3A, F1.6, Tianfa Building, Tian an Cyber Park, Fax: +86-755-83585701 Futian
More informationCOUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS
IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationRules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 2 Test Requirements for Electrical / Electronic Equipment and Systems Edition
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationCommunication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
More informationGain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
More informationApplication Note AN001
AN001 SRD regulations for licence free transceiver operation By P. M. Evjen Keywords CEPT recommendations ETSI standards R&TTE directive Part 15 devices Type approval Equipment testing Operating frequency
More information8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
More informationCE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board
CE EMC Test Report APPLICANT EQUIPMENT BRAND NAME MODEL NAME : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board : Texas Instruments : WL1835MODCOM8B STANDARD : ETSI EN 301 489-1 V1.9.2
More informationT200, PTP/IEEE 1588 Grandmaster Clock and
T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS receiver, OCXO or Rubidium oscillator 1 Bd d Armor 22300 LANNION - FRANCE contact@heoldesign.com 1 HEOL-T200 : PERFORMANCE
More informationDSA800 Series Spectrum Analyzer
DSA800 Series Spectrum Analyzer Configuration Guide This guide is used to help users to configure DSA800 series spectrum analyzer according to their requirements. You can get an overall understanding of
More informationTEST REPORT FROM RFI GLOBAL SERVICES LTD
FROM RFI GLOBAL SERVICES LTD Partial Test of: BTM411 To: EN 300 328 V1.7.1 (2006-10) Test Report Serial No: RFI/RPT1/RP76018JD01A This Test Report Is Issued Under The Authority Of Brian Watson, Operations
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More informationCond-IS RF Conducted Immunity System
Cond-IS RF Conducted Immunity System About RF Conducted Immunity In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) RF Conducted Immunity compliance verification
More informationDual Chamber Temporary External Pacemaker
5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes
More informationR&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6
More informationJens-EMC ApS. Randersvej 6 DK-8600 Silkeborg Denmark. EMC test report 2010-01-11-SeaCom. AC48/SeaCom1000 & AC128/SeaCom2100
Jens-EMC ApS Randersvej 6 DK-8600 Silkeborg Denmark Test lab (+45) 86 84 91 66 Mobile(+45) 40 10 90 33 jko@jens-emc.dk www.jens-emc.dk CVR 27 21 47 62 EMC Consultancy EMC test report 2010-01-11-SeaCom
More informationCE MARK TECHNICAL FILE
CE MARK TECHNICAL FILE of WLAN 802.11ABG MINIPCI Model DCMA-81;CM10;VZA-82 Contains: 1. Declaration of Conformity 2. ETSI EN300 328 or/& ETSI EN301 893 test report 3. ETSI EN301 489-1 and ETSI EN301 489-17
More informationLoop-O9310 4E1 or 4T1 Fiber Optical Mux
Loop-O930 E or T Fiber Optical Mux Features Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps (optional) One V.35, X.2, RS9/V.36,
More informationDual Fiber SFP Series
SFP-ZX, EZX and XZX series SFP Single-Mode, Dual Fiber Transceiver for 1.25Gbps FC/GBE Features Up to 4.25Gbps Data Rate 1550nm DFB 80km with 9/125 µm SMF 120km with 9/125 µm SMF 160km with 9/125 µm SMF
More informationQuick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
More informationAXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
More informationLevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationIndustrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter
Industrial 10/100/BASE-T to 100/BASE-X SFP Media Converter Physical Port 1-port 10/100/BASE-T RJ45 with auto MDI / MDI-X function 1 SFP interface, 100/BASE-X dual mode (auto detection) Layer 2 Features
More informationInstallation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C
/Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers
More informationIES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction
IES-3080/3062 Series Features Industrial 8-port managed Ethernet switch Fastest Redundant Ethernet Ring: O-Ring (recovery time < 10ms over 250 units of connection) Open-Ring supports the other vendor s
More informationMy first Hirschmann: The SPIDER family of switches.
My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running
More informationData Communications Competence Center
Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation
More informationChrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
More informationANSI Watthour Meter Testing & Certification Programs
ANSI Watthour Meter Testing & Certification Programs By Jim Reed Manager, Meter Accuracy Lab and Manasi Bhandiwad Manager, EMC Lab Laboratories, Inc. First in Certification Accreditations and Recognitions
More informationApplication Server V240 Platform
Application Server V240 Platform The V240 Application Server (V240) features four hot-swappable disks with redundant power supplies for reliable system performance. The server also has three PCI slots
More informationCisco Unified IP Phone Power Injector
Data Sheet Cisco Unified IP Phone Power Injector The Cisco Unified IP Phone Power Injector (Figure 1) increases the deployment flexibility of Cisco Unified IP phones by providing an alternative powering
More informationAgilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
More information8-Port 10/100M N-Way Mini Switch
1 8-Port 10/100M N-Way Mini Switch User Guide Introduction 2 This user guide is applied to the 8 ports 10/100M N-Way Mini Switch. The 8-Port 10/100M N-Way Mini Switch is designed for easy installation
More informationAN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x
TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide
More information30 In Compliance October 2014 www.incompliancemag.com
30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,
More information1000 BASE-X SFP. Key Features DATA SHEET HIGHLIGHTS 1000BASE-SX 1000BASE-LX 1000BASE-ZX 1000BASE BX-D*
DATA SHEET 1000 BASE-X SFP HIGHLIGHTS Extreme Networks pluggable optics provide physical layer connectivity for optical-port modular switch IO blades and optical-port stackable switches. Provides a range
More informationIndoor / Outdoor Antenna
z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302
More informationProCurve Switch 8000m (J4110A) and Switch 8000m
ProCurve Switch 4000m and Switch 8000m The ProCurve Switch 4000m and 8000m are managed modular 10/100/1000 desktop switches that provide scalable, expandable, low-cost migration to 10/100 switching for
More informationPE10G2T Dual Port Fiber 10 Gigabit Ethernet TOE PCI Express Server Adapter Broadcom based
PE10G2T Dual Port Fiber 10 Gigabit Ethernet TOE PCI Express Server Adapter Broadcom based Description Silicom 10Gigabit TOE PCI Express server adapters are network interface cards that contain multiple
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE TESTING, LLC 1724 S Nevada Way Mesa, AZ 85204 Phone: 480 926 3100 Michael Schafer (Authorized Representative/President) Email michaels@compliancetesting.com
More information