Schedule of Accreditation Issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Size: px
Start display at page:

Download "Schedule of Accreditation Issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK"

Transcription

1 Issued by High Street, Feltham, Middlesex, TW13 4UN, UK Academy Place 1-9 Brook Street Brentwood Essex CM14 5NQ Contact: Mr G Blake Tel: +44 (0) Fax: +44 (0) geoff.blake@intertek.com Website: Locations where activities covered by the above Accreditation are undertaken Intertek House Cleeve Road Leatherhead Surrey KT22 7SB United Kingdom Hilton House Corporation Street Rugby Warwickshire CV21 2DN United Kingdom Deeside Lane Chester CH1 6DD United Kingdom Davy Avenue Knowhill Milton Keynes Bucks MK5 8NL United Kingon Assessment Manager: JG2 Page 1 of 35

2 DETAIL OF ACCREDITATION Section Page 1 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS. 3 2 CABLES AND CORDS 3 3 CABLE TRUNKING, CONDUIT AND FITTINGS 4 4 CIRCUIT BREAKERS 5 5 CONTROLS AND COMPONENTS 6 6 ELECTRICAL WIRING ACCESSORIES 7 7 ELECTRICAL SYSTEMS 11 8 ENCLOSURES 12 9 FUSES HOUSEHOLD APPLIANCES AND LUMINAIRES RELAYS SWITCHGEAR AND CONTROLGEAR TRANSFORMERS AND REACTORS INFORMATION TECHNOLOGY EQUIPMENT ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES CONSTRUCTION PRODUCTS MICROGENERATION FIRE & SECURITY PRODUCTS WIND ENERGY ACCREDITATION FOR THE PURPOSE OF NOTIFIED BODY ACTIVITY 29 Where the BS EN or IEC standards have exact equivalents in EN s, those EN standards are also included in the accreditation. Assessment Manager: JG2 Page 2 of 35

3 SECTION 1: AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS Audio, video and similar electronic apparatus. Safety requirements BS EN 60065:2002 IEC 60065:2001 SECTION 2: CABLES AND CORDS Insulated cables and flexible cords for use in high temperature zones BS 6141:1991 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements IEC :2007 Test Methods IEC :2003 Non-sheathed cables for fixed wiring IEC :1997 Sheathed cables for fixed wiring IEC :1997 Flexible cables (cords) IEC :2003 Lift cables and cables for flexible connections IEC :2001 Flexible cables screened and unscreened with two or more conductors IEC :2003 Cables CENELEC HD 21 CENELEC HD 22 Assessment Manager: JG2 Page 3 of 35

4 SECTION 3: CABLE TRUNKING, CONDUIT AND FITTINGS Non-metallic conduits and fittings for electrical installations Fittings and components of insulating material BS :1984 Rigid conduits, fittings and components of insulating material BS :1982 Cable trunking Steel surface trunking BS :1971 (Withdrawn) Steel underfloor (duct) trunking BS :1973 Trunking made of insulating material BS :1982 Specification for conduit systems for cable management General requirements BS EN :1994 Rigid conduit systems Pliable conduit systems Flexible conduit systems Specification for conduit systems for cable management. Particular requirements. Conduit systems buried underground. Conduit systems for cable management. Outside diameters of conduits for electrical installations and threads for conduits and fittings. BS EN :1996 (Withdrawn) BS EN :1996 (Withdrawn) BS EN :1996 (Withdrawn) BS EN :1994 BS EN 60423:2007 IEC 60423:2007 Conduit systems for cable management General requirements BS EN :2008 IEC :2008 Rigid conduit systems BS EN :2004 IEC :2002 Assessment Manager: JG2 Page 4 of 35

5 SECTION 3: CABLE TRUNKING, CONDUIT AND FITTINGS (cont d) Pliable conduit systems BS EN :2004 IEC :2002 Flexible conduit systems BS EN :2004 IEC :2002 Conduit systems buried underground BS EN :2010 IEC :2004 SECTION 4: CIRCUIT BREAKERS Specification for a.c. voltage-operated earth-leakage circuit breakers BS 842:1965 General requirements for circuit breakers for voltages above V IEC Edition BS EN :2009 Circuit breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. operation BS EN :2003 IEC :2002 Circuit-breakers for a.c. and d.c. operation BS EN :2006 IEC :2000 Residual current operated circuit-breakers without integral overcurrent protection for household and similar used (RCCBs) BS EN :2004 IEC :1996 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) BS EN :2004 IEC :1996 Assessment Manager: JG2 Page 5 of 35

6 SECTION 5: CONTROLS AND COMPONENTS General requirements for residual current operated protective devices IEC/TR 60755:2008 High-voltage Alternating- Current Circuit-Breakers CENELEC HD 348 Thermal-links. Requirements and application guide BS EN 60691:2003 IEC 60691:2002 Automatic controls for household and similar use BS EN :2001 IEC :1999 BS EN :1995 IEC :1993 BS EN :1992 IEC :1986 and the 2-XX series of standard Switches for appliances Switches for appliances. General requirements. BS EN :2002+A2:2008 IEC :2002 Cord switches BS EN :1993 IEC :1992 Independently mounted switches BS EN :2005 IEC :2003 Change-over selectors BS EN :1995 IEC :1994 Lamp controlgear BS EN :2008 IEC :2007 BS EN :2001 IEC :2000 and the -2-XX series of standard Assessment Manager: JG2 Page 6 of 35

7 SECTION 6: ELECTRICAL WIRING ACCESSORIES Ceiling roses BS 67:1987 Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adapters BS 546: A rewireable and non-rewireable plugs BS :1995 IS 401: 1997 MS 589 Part 1: 1987 SS 145 Part 1: 1997 SASO 2203: 2003 SASO 443: A switched and unswitched socket-outlets BS :1995 MS 589 Part 2: 1987 SS 145 Part 2: 1997 SASO 2203: 2003 SASO 443: A adapters BS :1995 SS246: 1996 MS 589 Part 3: A fused connection units switched and unswitched BS :1995 MS 589 Part 4: 1987 Fused conversion plugs BS :1995 Cooker control units BS 4177: pin plugs and shaver socket-outlets BS 4573:1970 Boxes for the enclosure of electrical accessories BS 4662:2006 Electrical accessories not covered by other British s BS 5733:1995 BS 5733: 2010 Assessment Manager: JG2 Page 7 of 35

8 SECTION 6: ELECTRICAL WIRING ACCESSORIES (cont d) Luminaire supporting couplers (LSC s) BS 6972:1988 Portable residual current devices BS 7071:1992 Socket outlets incorporating residual current devices BS 7288:1990 Bayonet lampholders with enhanced safety BS 7895:1997 Flat non-rewirable two-pole plugs 2.5 A 250 V, with cord, for the connection of class II-equipment for household and similar purposes BS EN 50075:1991 Specification for lamp caps and holders together with gauges for the control of interchangeability and safety Lamps caps BS EN :1993 IEC DB-12M:2012 Lampholders BS EN :1993 IEC DB-12M:2012 Gauges BS EN :1993 IEC DB-12M:2012 Edison screw lampholders BS EN 60238:2004 IEC 60238:2004 Plugs, socket-outlets and couplers for industrial purposes BS EN :1999 IEC :1999 Appliance Connectors for household and similar general purposes General requirements BS EN :2001 IEC :2001 Assessment Manager: JG2 Page 8 of 35

9 SECTION 6: ELECTRICAL WIRING ACCESSORIES (cont d) Sewing machine couplers BS EN :2001 IEC :2000 Interconnection couplers for household and similar equipment Appliance coupler with a degree of protection higher than IPX0 BS EN :1999 IEC :1998 BS EN :1999 IEC :1998 Appliance couplers for household and similar general purposes. Couplers dependent on appliance weight for engagement. BS EN :2006 IEC :2005 Switches for household and similar fixed electrical installations BS EN :1999 IEC :1998 Electronic switches BS EN :2004 IEC :2002 Electromagnetic remote-control switches (RCS) BS EN :2006 IEC :2006 Time delay switches BS EN :2006 IEC :2006 Isolating switches BS EN :2005 Cord-sets BS EN 60799:1998 IEC 60799:1998 Miscellaneous lampholders General requirements and tests BS EN :2004 IEC :2004 Lampholders S14 BS EN :1997 IEC :1994 Assessment Manager: JG2 Page 9 of 35

10 SECTION 6: ELECTRICAL WIRING ACCESSORIES (cont d) Connectors for LED-modules BS EN :2006 IEC :2006 Connecting devices for low-voltage circuits for household and similar purposes General requirements BS EN :2004 IEC :2002 With screw-type clamping units BS EN :2004 IEC :2002 With screwless-type clamping units BS EN :2004 IEC :2002 With insulation-piercing clamping units BS EN :2004 IEC :2002 Twist-on connecting devices BS EN :2005 IEC :2004 Bayonet Lampholders BS EN 61184:2008 IEC 61184:2008 Cable Reels BS EN 61242:1997 IEC 61242:1995 Connectors BS EN 61984:2001 IEC 61984:2001 Sound signalling devices for household and similar purposes IEC 62080:2008 Assessment Manager: JG2 Page 10 of 35

11 SECTION 6: ELECTRICAL WIRING ACCESSORIES (cont d) Electrical Wiring Accessories ASTA s ASTA 102 ASTA 104 ASTA 106 ASTA 107 ASTA 109 ASTA 120 ASTA 122 ASTA 124 ASTA 125 ASTA 129 ASTA 131 ASTA 132 ASTA 134 ASTA 138 ASTA 146 ASTA 150 ASTA 153 ASTA 154 ASTA 158 ASTA 160 SECTION 7: ELECTRICAL SYSTEMS Electrical systems in office furniture and office screens BS 6396:2008 Powertrack systems Powertrack systems. General requirements. BS EN :2003 IEC :2003 Powertrack systems intended for wall and ceiling mounting BS EN :2006 IEC :2006 Powertrack systems. Particular requirements for powertrack systems intended for on floor or under floor installation BS EN :2009 IEC :2009 Assessment Manager: JG2 Page 11 of 35

12 SECTION 8: ENCLOSURES Degrees of protection provided by enclosures (IP code) BS EN 60529:1992 IEC 60529:1989 SECTION 9: FUSES Cartridge fuse-links (rated up to 5 amperes) for a.c. and d.c. service BS 646:1958 Cartridge fuses for a.c. circuits in domestic and similar premises BS 1361:1971 General purpose fuse links for domestic and similar purposes (primarily for use in plugs) BS 1362:1973 SS 167: 1977 Semi-enclosed electric fuses (ratings up to 100 amperes and 240 volts to earth) BS 3036:1958 Specification for high-voltage fuses for the external protection of shunt power capacitors BS 5564:1978 IEC 60549:1976 Single phase street lighting fuses (cut-outs) for lowvoltage public electricity distribution systems. 25 A rating for highway power supplies and street furniture. BS 7654:1997 High-voltage fuses Current-limiting fuses BS EN :2009 IEC :2009 Fuses for voltages exceeding 1000 V a.c. Expulsion fuses. Fuses for voltages exceeding 1000 V a.c. Guide to the determination of short circuit power factor. BS :1956 BS :1990 IEC :1976 Assessment Manager: JG2 Page 12 of 35

13 SECTION 9: FUSES (cont d) Miniature fuses Definitions for miniature fuses and general requirements for miniature fuse-links BS EN :2006 IEC :2006 Cartridge fuse-links BS EN :2003 IEC :2003 Specification for sub-miniature fuse-links BS EN :1996 IEC :1988 Universal modular fuse-links (UMF). Through-hole and surface mount types. BS EN :2005 IEC :2005 Fuse-holders for miniature cartridge fuse-links BS EN :1994 IEC :1994 Low-voltage fuses General requirements BS EN :2007 BS 88-1:2007 IEC :2006 Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application). Examples of standardized systems of fuses A to I. BS 88-2:2007 IEC :2010 BS HD : 2010, BS 88-2: 2010 Examples of standardized systems of fuses A to F BS 88-3:2007 IEC :2006 BS HD : 2010, BS 88-3: 2010 Supplementary requirements for fuse-links for the protection of semiconductor devices BS EN :2007 BS 88-4:2007 IEC :2006 BS EN : 2009, IEC : 2009 Assessment Manager: JG2 Page 13 of 35

14 SECTION 10: HOUSEHOLD APPLIANCES AND LUMINAIRES Specification for safety of electrically heated blankets, pads and similar flexible heating appliances for household use BS EN 60967:1991 (Withdrawn) IEC 60967:1988 (Withdrawn) Household and Similar Electrical Appliances BS EN : A11:2014 BS EN :2002 IEC :2002 BS EN :1995 IEC :1991 and the -2-XX series of standard Luminaires BS EN :2008 IEC :2008 and the 2-XX series of standard SECTION 11: RELAYS Electrical relays Single input energizing quantity measuring relays with dependent or independent time Insulation coordination for measuring relays and protection equipment. Requirements and tests. BS EN :1998 IEC :1989 BS EN :2001 IEC :2000 Measuring relays and protection equipment BS EN :1995 IEC :1986 Thermal electrical relays BS EN :1998 IEC :1990 Specified time relays for industrial use. BS EN :1997 IEC :1996 Assessment Manager: JG2 Page 14 of 35

15 SECTION 12: SWITCHGEAR and CONTROLGEAR Specification for distribution assemblies for reduced low voltage electricity supplies for construction and building sites BS 4363:1998 Line traps for power line carrier systems BS 4996:1973 IEC 60353:1989 Mining type flameproof supply and control units for use on systems up to 1100 V Direct-on-line motor starters BS :1993 Circuit breaker units BS :1993 Air-cooled lighting transformer units BS :1993 Air-cooled transformers to power drilling machines BS :1993 Low-voltage controlgear. Specification for semiconductor contactors (solid state contactors). Specification for controlgear for voltages up to and including 1000 V a.c. and 1200 V d.c. Additional requirements for contactors subject to. BS :1987 BS :1988 IEC :1985 Surge arresters Non-linear resistor type gapped surge arrestors for a.c. systems Metal-oxide surge arresters without gaps for a.c. systems BS EN :1994 IEC :1991 BS EN :2004 IEC :2004 Assessment Manager: JG2 Page 15 of 35

16 SECTION 12: SWITCHGEAR and CONTROLGEAR (cont d) Specification for high-voltage alternating current switch-fuse combinations Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kv and above IEC Ed. 2: 2011 BS EN :2004 On load tap changers BS EN :2003 IEC :2003 Specification for high-voltage switches Switches for rated voltages above 1 kv and less than 52 kv High-voltage switches for rated voltages of 52 kv and above IEC Ed.1:2011 BS EN :2011 BS EN :209 IEC :209 Low-voltage switchgear and control gear assemblies Type-tested and partially type-tested assemblies BS EN :1999 IEC :1999 AS/NZS :2002 IEC :2009 IEC : 2011 BS EN : 2011 Power switchgear and controlgear assemblies IEC :2009 IEC : 2011 BS EN : 2011 Busbar trunking systems (busways) BS EN :2000 IEC :2000 AS/NZS :2002 IEC : 2012 BS EN : 2012 Low-voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access to their use. Distribution boards. BS EN :1991 IEC :1990 IEC : 2012 BE EN : 2012 Assessment Manager: JG2 Page 16 of 35

17 SECTION 12: SWITCHGEAR and CONTROLGEAR (cont d) Assemblies for construction sites (ACS) BS EN :2004 IEC :2004 Assemblies for power distribution in public networks BS EN :2006 IEC :2006 IEC : 2010 BS EN : 2011 Low voltage assemblies internal arc testing IEC/TR 61641:2008 High voltage switchgear and controlgear BS EN :2008 IEC :2007 Synthetic testing BS EN :2006 IEC :2006 Alternating current disconnectors and earthing switches BS EN :2002 IEC :2001 AC switch-fuse combinations BS EN :2003 IEC :2002 Power Capacitors LV power factor correction banks IEC 61921: 2003 BS EN 61921: 2003 AC metal-enclosed switchgear and controlgear for rated voltages above 1 kv and up to and including 52 kv BS EN :2004 IEC :2003 High-voltage/ low-voltage prefabricated substation BS EN :2007 IEC :2006 Specification for low-voltage switchgear and controlgear General rules BS EN :2007 IEC :2007 Circuit-breakers BS EN :2006 IEC :2006 Switches, disconnectors, switch-disconnectors and fusecombination units BS EN :1999 IEC :1999 Assessment Manager: JG2 Page 17 of 35

18 SECTION 12: SWITCHGEAR and CONTROLGEAR (cont d) Contactors and motor-starters. Electromechanical contactors and motor-starters. BS EN :2001 IEC :2001 Specification for low-voltage switchgear and controlgear (cont d) AC semiconductor motor controllers and starters BS EN :2000 IEC :1999 AC semiconductor controllers and contactors for non-motor loads BS EN :2000 IEC :1999 SECTION 13: TRANSFORMERS AND REACTORS Resistance welding water-cooled transformers of the press package and portable types BS :1989 BS :1989 ISO Power transformers General BS EN :1997 IEC :1993 Power transformers. Temperature rise. BS EN :1997 IEC :1993 Insulation levels, dielectric tests and external clearances in air Guide to the lightning impulse and switching impulse testing. Power transformers and reactors. BS EN :2001 IEC :2000 BS EN :2002 IEC :2002 Ability to withstand short-circuit BS EN :2006 IEC :2006 Application guide BS IEC :1997 IEC :1997 Determination of sound levels BS EN :2001 IEC :2001 Assessment Manager: JG2 Page 18 of 35

19 SECTION 13: TRANSFORMERS AND REACTORS (cont d) Power transformers (cont d) Dry-type transformers BS EN :2004 IEC :2004 Self-protected liquid-filled transformers BS EN :2006 IEC :2006 Tap-changers. Performance requirements and test methods. BS EN :2003 IEC :2003 Reactors BS EN 60289:1988 Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1kV General. Performance, testing and rating. Safety requirements. Guide for installation and operation. BS EN :1998 IEC :1996 Ageing test, self-healing test and destruction test BS EN :1996 IEC :1995 Convertor transformers. Transformers for industrial applications BS EN :1999 IEC :1997 Safety of power transformers, power supply units and similar products BS EN :2005 IEC :2005 BS EN :1998 IEC :1997 and the -2-XX series of standard Transformers, Reactors, etc CENELEC HD S1 1:1983 CENELEC HD 464 S1:1988 CENELEC HD 553 S2:1993 Assessment Manager: JG2 Page 19 of 35

20 SECTION 13: TRANSFORMERS AND REACTORS (cont d) Instrument Transformers Instrument Transformers General Requirements BS EN :2009 IEC :2007 Instrument Transformers Current transformers BS EN :2012 IEC :2012 Instrument Transformers Inductive voltage transformers BS EN :2011 IEC :2011 Instrument Transformers Combined transformers IEC :2013 SECTION 14: INFORMATION TECHNOLOGY EQUIPMENT Information technology equipment. Safety. General requirements. Information technology equipment. Safety. Remote power feeding. Information technology equipment. Safety. Equipment installed outdoors. Information technology equipment. Safety. Large data storage equipment. BS EN :2006 IEC :2005 BS EN :2002 IEC :2001 BS EN :2003 IEC :2002 BS EN :2006 IEC :2005 BS EN :2006 IEC :2005 Assessment Manager: JG2 Page 20 of 35

21 SECTION 15: ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE Electrical equipment for measurement, control and laboratory use BS EN :2001 IEC :2001 Laboratory equipment for the heating of materials BS EN :2003 IEC :2003 Hand held probe assemblies for electrical measurement and test Hand held current clamps for electrical measurement and test Automatic and semi-automatic laboratory equipment for analysis and other purposes BS EN :2002 IEC :2002 BS EN :2002 IEC :2002 IEC : 2002 BS EN : 2002 In-vitro diagnostic (IVD) medical equipment IEC : 2002 BS EN : 2002 Assessment Manager: JG2 Page 21 of 35

22 SECTION 16: ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES Electrical apparatus for explosive gas atmospheres: General requirements BS EN :2006 IEC :2006 BS EN :2004 IEC :2004 Oil immersion o BS EN 50015:1998 BS EN 50015:1994 IEC :1995 Pressurised apparatus p BS EN :2007 IEC :2001 Powder filling q IEC :2003 BS EN 50017:1998 IEC :1997 BS EN 50017:1994 Flameproof enclosures d BS EN :2007 IEC :2003 Increased safety e BS EN :2007 IEC :2006 BS EN :2003 Intrinsic safety i BS EN :2007 IEC :1999 BS EN 50020:2002 Encapsulation m BS EN :2004 IEC :2004 Type of protection n BS EN :2005 IEC :2005 BS EN :2003 IEC :2001 Assessment Manager: JG2 Page 22 of 35

23 SECTION 16: ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES (cont d) Equipment Group II Category IG/Zone 0 BS EN :2007 Electrical Apparatus for use in dust atmospheres General requirements BS EN :2006 EN :2006 IEC :2004 Protection by enclosure td BS EN :2004 IEC :2004 Non electrical equipment - General requirements BS EN :2001 Non electrical equipment - Flow restriction fr BS EN :2004 Non electrical equipment - Flameproof enclosure d BS EN :2005 Non electrical equipment - Constructural safety c BS EN :2003 Non electrical equipment - Control of ignition source b BS EN :2005 Explosion prevention basic concepts and methodology BS EN :1998 Metering pumps and fuel dispensers BS EN :2004 Electric surface heating devices BS 6351:Part 1:1983 Metallic cabling glands BS 6121:Part 1:2005 Assessment Manager: JG2 Page 23 of 35

24 SECTION 16: ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES (cont d) Petroleum Forecourt Dispensers BS :1991 (withdrawn) BS :1991 (withdrawn) BS :1991 (withdrawn) Electrical apparatus for the detection and measurements of combustible gases: General requirements BS EN 50054:1999 (withdrawn) Performance requirements for Group I apparatus indicating up to 5% (V/V) methane in air BS EN 50055:1999 (withdrawn) Performance requirements for Group I apparatus indicating up to 100%(V/V) methane in air BS EN 50056:1999 (withdrawn) Performance requirements for Group II apparatus indicating up to 100% lower explosive limit BS EN 50057:1999 (withdrawn) Performance requirements for Group II apparatus indicating up to 100% (V/V) gas BS EN 50058:1999 (withdrawn) Electrical apparatus for use in the presence of combustible dust BS EN :1999 Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust BS EN 50303:2000 Reciprocating Internal Combustion Engines for use in potentially explosive atmospheres Group II engines for flammable gas and vapour atmospheres BS EN :2000 Assessment Manager: JG2 Page 24 of 35

25 SECTION 16: ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES (cont d) Reciprocating Internal Combustion Engines for use in potentially explosive atmospheres (cont d) Group I engines for workings susceptible to firedamp and/or combustible dust BS EN :2000 Group II engines for flammable dust atmospheres BS EN :2000 Small Craft; Electrical Devices: Protection against ignition of surrounding flammable gases BS EN 28846:1993 Flame arrestors BS 7244:1990 BS EN 12874:2001 SECTION 17: CONSTRUCTION PRODUCTS Manufacture of Fire Doors & Door Hardware including Metal, Composite, Timber leaves and doorsets. Hardware to include Hinges, Locks & Latches, door closers and hold open devices EN :2008 EN :2008 ISO 3008:2006 EN 1935:2002 EN 12209:2003 EN 1154:1996 EN 1155:1997 Intertek Document Manufacture of Passive Fire s BS :1987 BS :1987 ENV :2002 ENV :2008 EN :2007 Intertek Document Installation of passive Fire s Intertek Document Where the BS EN or IEC standards have exact equivalents in EN s, those EN standards are also included in the accreditation. Assessment Manager: JG2 Page 25 of 35

26 SECTION 18: MICROGENERATION MCS Certification Solar Collectors Solar Photovoltaic Panels Micro & Small Wind Turbines Heat Pumps Micro Hydroturbines MCS scheme Requirements; (DECC) MCS Solar Collectors MCS Solar Photovoltaic Panels MCS Micro & Small Wind Turbines MCS Heat Pumps MCS Generic FPC Requirements MCS 016 & 018 Micro Hydroturbines MCS Testing and Acceptance Criteria SECTION 19: FIRE & SECURITY PRODUCTS Fire Control and Indicating Equipment Sounders Power Supply Equipment Heat detectors Smoke detectors Flame detectors Manual Call points Beam smoke Compatability Voice Alarm Control and Indicating Equipment Short circuit protection devices Input / output devices Aspirating smoke detectors Transmissions equipment Beacons Loudspeakers Radio devices Duct smoke alarms Domestic smoke alarms Multi sensor smoke/heat Multi sensor smoke/co Carbon Monoxide detectors EA CertAlarm Sector scheme (Type 5 schemes) TickMark Scheme (Type 5 schemes) Fire EN 54-2:1997 +A1 EN 54-3:2001 +A1,A2 EN 54-4:1998 +A1,A2 EN 54-5:2001 +A1 EN 54-7:2001 +A1,A2 EN 54-10:2002 +A1 EN 54-11: A1 EN 54-12:2002 EN 54-13:2005 EN 54-16:2008 EN 54-17:2005 EN 54-18:2005 EN 54-20: 2006 EN 54-21:2006 EN 54-23:2010 EN 54-24: 2008 EN 54-25:2008 pren 54-27:2008 EN 14604:2005 pren : October 2009 pren 54-30: March 2009 EN :2010 +A1:2012 Assessment Manager: JG2 Page 26 of 35

27 SECTION 19: FIRE & SECURITY PRODUCTS (cont d) Security EMC standard for Fire, Intruder and Social Alarms EMC standard for Fire, Intruder and Social Alarms Environmental tests System Requirements Control and Indicating Equipment Warning devices (sounders) Power Supplies Passive Infrared Detectors Microwave detectors Combined passive and microwave detectors Combined passive and ultrasonic detectors Opening contacts (magnets) Radio equipment use for interconnection Alarm Verification Supervised Premises Transceiver General requirements System requirements General requirements General requirements for alarm transmission equipment Requirements for alarms using dedicated paths Requirements using Public Switched Telephone Networks Requirements with voice communicators using PSTN Requirement for packet switched network PSN Requirements for Supervised Premises Transmission General requirements Requirements for alarms using dedicated paths Requirements using Public Switched Telephone Networks Requirements with voice communicators using PSTN Social Alarms system requirements Social alarms trigger devices Social alarms local unit and controller Social alarms interconnection and communication EA CertAlarm Sector scheme (Type 5 schemes) TickMark Scheme (Type 5 schemes) Security EN :2005+A1,A2 EN :2011 EN :1999 EN :2006+A1 EN :2009 EN : 2009 EN : 2008 EN :2008 EN :2008 EN :2008 EN :2008 EN :2008 EN :2005+A1 pren : April 2011 pren : April 2011 EN :1997 EN :2000 EN :2012 EN : 1998+A1,A2 EN :1998 EN :1998 EN :1998 EN :2008 EN :2013 EN :1998 EN :1998 EN :1998 EN :1998 EN :2002 EN :2000 EN :2001 EN :2004 Rules for alarm transmission sysem Burglar Alarms SSF 114 issue 2:2009 Assessment Manager: JG2 Page 27 of 35

28 SECTION 20: WIND ENERGY Conformity testing and of wind turbines: Type (excluding offshore wind turbines), Component, Prototype. BS EN :2011 IEC :2010 BS EN :2005 +A1:2010 IEC :2010, Edition 3 BS EN :2006 IEC :2006, Edition 2 Danish Executive order Code 73 See next page for Section 21: ACCREDITATION FOR THE PURPOSE OF NOTIFIED BODY ACTIVITY Assessment Manager: JG2 Page 28 of 35

29 SECTION 21: ACCREDITATION FOR THE PURPOSE OF NOTIFIED BODY ACTIVITY Accreditation for the purpose of Notified Body Activity taking into account EA2/17 Directive / Regulation Conformity Assessment procedure/ Module/article Category of products or individual products Essential requirements: specification / Properties/s The Construction s RegulationEU) No 305/2011 Annex V- Certification Body (AVCP) System 1 Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Control and indicating devices (fire safety), 96/577/EC EN 54-16:2008 EN 54-2:1997 EN 54-2:1997/A1:2006 EN 54-2:1997/AC:1999 Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Manual call points (fire safety), 96/577/EC EN 54-11:2001 EN 54-11:2001/A1:2005 Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Input/output devices (fire safety), 96/577/EC EN 54-18:2005 EN 54-18:2005/AC:2007 EN 54-24:2008 EN 54-25:2008 EN 54-25:2008/AC:2010 EN 54-25:2008/AC:2012 Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Alarm devices (fire safety), 96/577/EC EN 14604:2005 EN 14604:2005/AC:2008 EN 54-3:2001/A1:2002 EN 54-3:2001/A2:2006 Assessment Manager: JG2 Page 29 of 35

30 Directive / Regulation Conformity Assessment procedure/ Module/article Category of products or individual products Essential requirements: specification / Properties/s The Construction s Regulation (EU) No 305/2011 (cont d) Annex V- Certification Body (AVCP) System 1 (cont d) Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Short circuit isolators (fire safety), 96/577/EC EN 54-17:2005 EN 54-17:2005/AC:2007 Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Smoke, heat and flame detectors (fire safety), 96/577/EC EN 54-10:2002 EN 54-10:2002/A1:2005 EN 54-12:2002 EN 54-5:2000/A1:2002 EN 54-7:2000/A1:2002 EN 54-7:2000/A2:2006 Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Foam systemskits (fire safety), 96/577/EC EN 54-7:2000/A1:2002 EN 54-7:2000/A2:2006 Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Fire alarm systems-kits (fire safety), 96/577/EC EN 54-21:2006 Assessment Manager: JG2 Page 30 of 35

31 Directive / Regulation Conformity Assessment procedure/ Module/article Category of products or individual products Essential requirements: specification / Properties/s The Construction s Regulation (EU) No 305/2011 (cont d) Annex V- Certification Body (AVCP) System 1 (cont d) Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Combined fire detection and fire alarm systems-kits (fire safety), 96/577/EC EN 54-20:2006 EN 54-20:2006/AC:2008 Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1) : - Power supplies (fire detection/alarm components) (fire safety), 96/577/EC EN 54-4:1997 EN 54-4:1997/A1:2002 EN 54-4:1997/A2:2006 EN 54-4:1997/AC:1999 Doors, windows, shutters, blinds, gates and related building hardware (1/1) : - Building hardware related to doors, gates and windows (fire/smoke compartmentation and on escape routes), 99/93/EC EN 1125:2008 EN 1154:1996/A1:2002 EN 1154:1996/A1:2002/AC:2006 EN 1155:1996/A1:2002/AC:2006 EN 1155:1997/A1:2002 EN 12209:2003 EN 12209:2003/AC:2005 EN 179:2008 EN 1935:2002 EN 1935:2002/AC:2003 Assessment Manager: JG2 Page 31 of 35

32 Directive / Regulation Conformity Assessment procedure/ Module/article Category of products or individual products Essential requirements: specification / Properties/s The Low Voltage Directive 2006/95/EC Implemented in the UK by The Electrical Equipment (Safety) Regulations 1994, No 3260) Reports to Article 8 and Opinions to Article 9 Audio, Video and Similar Electronic Apparatus; Cable Trunking, Conduit and Distribution Systems; Electrical and Electronic Controls; Electrical Wiring Accessories; Household and Similar Electrical Appliances; IT and Telecommunications Equipment; Lamps and Luminaires; Measurement, Control and Laboratory Equipment; Switchgear, Controlgear and Electrical Distribution Equipment; Transformers Principal elements of the Safety Objectives requirements Annex I of the Directive and Schedule 3 of the Regulations. Noise Emission in the Environment by Equipment for use Outdoors Directive 2000/14/EC as amended by 2005/88/EC Implemented in UK Law by: SI 1701/2001The Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001 (as amended by amending regulations SI 2001 No 3958 and SI 2005 No 3525) Internal Control of ion (Annex VI) (Schedule 9 of the SI) Unit Verification (Annex VII) (Schedule 10 of the SI) Schedule 1 for: Lawnmowers Lawn Trimmers/Lawn Edge Trimmers Power Generators Welding Generators Compressors Motor Hoes Conformity assessment procedures in accordance with Article 14 and Annexes VI and VII of the Directive and Regulation 10 and Schedules 9 and 10 of the SI. Assessment Manager: JG2 Page 32 of 35

33 Directive / Regulation Conformity Assessment procedure/ Module/article Category of products or individual products Essential requirements: specification / Properties/s Machinery Directive 2006/42/EC Implemented in UK Law by: SI 2008 No The Supply of Machinery (Safety) Regulations 2008 EC typeexamination (Annex IX Annex IV A, Machinery, Items 1-17, B, Safety Components, Items 1-5 of Schedule 4 Essential Health and Safety requirements Annex I of the Directive and Schedule 2 Part 1 Annex I of the Regulations. Gas Appliance Directive (90/396/EEC) Implemented in the UK by:- Gas Appliances (Safety) Regulations 1995 (SI 1995/1629) Annex II.1 EC Type Examination Annex II.2 EC Declartion of Conformity to Type Annex II.3 EC Declartion of Conformity to Type (guarantee of ion Quality) Annex II.5 EC Verification Annex II.6 EC Unit Verification Appliances burning Gaseous fuels used for:- Cooking Heating (up to 70kw) Hot water ion Refrigeration Lighting Washing Fittings Safety Devices Controlling devices (excluding electronic controls) Regulating Devices Sub assemblies Examination and approval against the Essential Requirements of Annex 1 Examination and approval of the Quality System in accordance with Annex II of the Directive Assessment Manager: JG2 Page 33 of 35

34 Directive / Regulation Conformity Assessment procedure/ Module/article Category of products or individual products Essential requirements: specification / Properties/s Electromagnetic Compatibility Directive 2004/108/EC Implemented in UK Law by: SI 2006 No The Electromagnetic Compatibility Regulations 2006 Technical Documentation review Industrial Equipment Information Technology Equipment Alarm Systems AV Equipment Railway Systems Laboratory and Test Equipment Transmission Systems Automotive Systems Domestic Appliances Military Equipment Essential Requirements Annex I of the Directive Radio Equipment and Telecommunications Terminal Equipment Directive 99/5/EC Implemented in UK Law by: The Radio Equipment and Telecommunications Terminal Equipment Regulations 2000 SI 2000 No 730 Annex IV Schedule 4 Technical Construction File Citizens Band Cordless Telephone Mobile (Cellular) Telephone Handsets Private/Professional Mobile Radio Radio Frequency Identification Satellite Earth Station Short Range Devices Telemetry/ Telecommand Wireless Microphone Essential Requirement Article 3 of the Directive and Schedule 3 of the Regulations Assessment Manager: JG2 Page 34 of 35

35 Directive / Regulation Conformity Assessment procedure/ Module/article Category of products or individual products Essential requirements: specification / Properties/s Equipment Intended for use in Potentially Explosive Atmospheres (ATEX) 94/9/EC (As Amended) Implemented in UK law by: The Equipment and Protective Systems Intended for use in Potentially Explosive Atmospheres Regulations 1996, No 192 (As Amended) Annex III / Schedule 6 EC-Type examination Annex IV /Schedule 7 ion QA Annex V / Schedule 8 verification Annex VI / Schedule 9 Conformity to type Equipment in :- Equipment group I, categories M1 and M2. Equipment group II, categories 1, 2 and 3. Essential Health and Safety Requirements, Annex II of the Directive and Schedule 3 of the Regulations Annex VII / Schedule 10 QA Annex IX / Schedule 12 Unit verification Article 8 (1) (b) (ii), Regulation 10 (3)(b) iii) Storage of Technical files Acknowledgment of receipt and retention of technical files Australian and New Zealand MRA Conformity Assessment Body Low Voltage s Sector Machinery s Sector Designation as a CAB in accordance with Chapter 1 END Assessment Manager: JG2 Page 35 of 35

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) 10.8.2002 Official Journal of the European Communities C 190/5 Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) (Text with EEA relevance)

More information

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS (PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,

More information

Nya och reviderade standarder 2014

Nya och reviderade standarder 2014 Här presenterar vi alla nya och reviderade standarder från år 2014. Standardlistan hittar du alltid på www.intertek.se/om-oss/intertekinfo Nya och reviderade standarder 2014 Standardnummer Namn Standarden

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

How To Understand The Electrical Power Supply Of A Power Supply System

How To Understand The Electrical Power Supply Of A Power Supply System 17 Circuit diagram symbols E 18 CIRCUIT DIAGRAM SYMBOLS electrical network elements three-phase line or cable single-phase line or cable short circuit earth electrode outgoing feeder supply incoming feeder

More information

AS/NZS 3000:2007 Amendment 2

AS/NZS 3000:2007 Amendment 2 AS/NZS 3000:2007 Amendment 2 Published 14 December 2012 Under Victorian legislation the day a revised standard is published it becomes the requirement. The aim of this document is to highlight the important

More information

David O Brien, CMP Products (David.OBrien@cmp-products.com)

David O Brien, CMP Products (David.OBrien@cmp-products.com) David O Brien, CMP Products (David.OBrien@cmp-products.com) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?

More information

IEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO. IEC 60034-1 Ed.13: Rotating electrical machines - Part 1: Rating and performance.

IEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO. IEC 60034-1 Ed.13: Rotating electrical machines - Part 1: Rating and performance. IEC PROJETOS EM VOTAÇÃO JULHO E AGOSTO IEC/TC 2 - Rotating machinery IEC 60034-1 Ed.13: Rotating electrical machines - Part 1: Rating and performance. IEC 60034-12 Ed.3: Rotating electrical machines -

More information

Electrical Safety and Another Regulation Amendment Regulation (No. 1) 2008

Electrical Safety and Another Regulation Amendment Regulation (No. 1) 2008 Queensland Electrical Safety and Another Regulation Amendment Regulation (No. 1) 2008 Subordinate Legislation 2008 No. 154 made under the Electrical Safety Act 2002 State Penalties Enforcement Act 1999

More information

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:

More information

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125

Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC3-12 MC3-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

The easy way to build switchgear and controlgear assemblies in compliance with the regulations The easy way to build switchgear and controlgear assemblies in compliance with the regulations A guide for partially type-tested switchgear and controlgear assemblies in compliance with EN 60 439 What

More information

International Electrotechnical Commission Standards

International Electrotechnical Commission Standards International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354

More information

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company -1- Contents Page 1. What Is CCC? 3 2. Procedure for Judging If a Product Is Subject to

More information

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket

More information

Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK

Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK info.uk@intertek.com +44 1788 578435 www.uk.intertek-etlsemko.com Author: Craig Diack-Evans Senior International Business Development Manager ASTA

More information

DEVICES OF PROTECTION AND COMMAND

DEVICES OF PROTECTION AND COMMAND COMPLEMENT Doc: 702-CRC-007-E Page: 1/24 Elaborated by: Laercio Santos Checked by: Karen Carolina Martins Rodrigo Omori Douglas Ferreira Nelson Coelho Approved by: Nelson Coelho Approval date: 14/07/2014

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting 12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

FAQs-Main switchboard design criteria

FAQs-Main switchboard design criteria FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Top Commercial / Residential Electrical Requirements *

Top Commercial / Residential Electrical Requirements * Department of Community Development Building Division 4800 West 92 nd Avenue Westminster, Colorado 80031 For Information call (303) 658-2075 Fax (303) 706-3922 www.westminsterpermits.com Top Commercial

More information

SELECTION OF FINAL CIRCUIT PROTECTION

SELECTION OF FINAL CIRCUIT PROTECTION SELECTION OF FINAL CIRCUIT PROTECTION By Phil Williams, Product Marketing Manager, Power Distribution Components, Eaton Executive summary The selection of devices for final circuit protection in electrical

More information

Fusible Disconnect Switch

Fusible Disconnect Switch Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit

More information

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters

4 IX D N E P P A Installation methods Current-carrying capacity and voltage drop for cables Reference method IET Wiring Matters 8 Appendix 4 of BS 7671 by Mark Coles Appendix 4, Current-carrying capacity and voltage drop for cables and flexible cords, has seen significant changes with the publishing of BS 7671:2008. This article

More information

e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN

e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services

More information

TECHNICAL SPECIFICATION FOR PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) SYSTEM FOR CONNECTION TO PUBLIC SWITCHED TELEPHONE NETWORK (PSTN)

TECHNICAL SPECIFICATION FOR PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) SYSTEM FOR CONNECTION TO PUBLIC SWITCHED TELEPHONE NETWORK (PSTN) TECHNICAL SPECIFICATION FOR PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) SYSTEM FOR CONNECTION TO PUBLIC SWITCHED TELEPHONE NETWORK (PSTN) Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia,

More information

Electrical Contractors Association

Electrical Contractors Association Electrical Contractors Association Presents BS 7671 2008: Amendment No 1 BS 7671: 2008 Amendment No 1, 2011 IEE Wiring Regulations Now called IET Wiring Regulations History 1882 first edition of the Wiring

More information

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant

More information

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of SKMM, 2007 FOREWORD

More information

NZECP 14: 1995 ISSN 0114-0663 COVER PAGE

NZECP 14: 1995 ISSN 0114-0663 COVER PAGE NZECP 14: 1995 ISSN 0114-0663 COVER PAGE NZECP 14:1995 NEW ZEALAND ELECTRICAL CODE OF PRACTICE FOR CONTROL PROTECTION AND SWITCHBOARDS Issued by the Office of The Chief Electrical Engineer, Energy and

More information

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Name of School: OPTIONAL INFORMATION Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Guidelines: This checklist

More information

Fire and Security Products and Services

Fire and Security Products and Services www.redbooklive.com Fire and Security Products and Services Making LPCB Approval work for you Not all fire and security products and services on the market can be trusted in the event of a fire or attempted

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out

More information

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment Evaluating Water-Damaged Electrical www.nema.org Evaluating Water-Damaged Electrical 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been

More information

The Intelligent AX1 Switchgear for Medium Voltage

The Intelligent AX1 Switchgear for Medium Voltage The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire

More information

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13 Interfacing electrification and system reliability Roger White Professional Head of Electrification and Plant Rail Abstract Integration is the term given to ensuring that the different elements of an electrified

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

ELECTRICIAN TRADE REGULATION

ELECTRICIAN TRADE REGULATION Province of Alberta APPRENTICESHIP AND INDUSTRY TRAINING ACT ELECTRICIAN TRADE REGULATION Alberta Regulation 274/2000 With amendments up to and including Alberta Regulation 122/2014 Office Consolidation

More information

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire

More information

TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS

TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of SKMM, 2007 FOREWORD

More information

Regulations for the Installation of Electrical Wiring, Electrical Equipment and Air Conditioning Equipment

Regulations for the Installation of Electrical Wiring, Electrical Equipment and Air Conditioning Equipment Regulations for the Installation of Electrical Wiring, Electrical Equipment and Air Conditioning Equipment Qatar General Electricity & Water Corporation KAHRAMAA Customer Services Department State of Qatar

More information

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

SF 6 Gas Insulated Switchgear Type SDF for 170 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment

More information

Switchgear and Metal-Enclosed Bus

Switchgear and Metal-Enclosed Bus Section 18 Switchgear and Metal-Enclosed Bus 180. SWITCHGEAR ASSEMBLIES 180A. General Requirements for All Switchgear. This rule covers general requirements for all switchgear. Examples of switchgear found

More information

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) Original Certificate DETAILS OF THE CLIENT Certificate reference: ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) Name: Address: PURPOSE

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

Errata NFPA 70. Proposed 2014 Edition

Errata NFPA 70. Proposed 2014 Edition Errata NFPA 70 National Electrical Code (Report on Proposals) Reference: 12-109 (Log #1618) Panel Meeting Action Proposed 2014 Edition The National Electrical Code Technical Correlating Committee notes

More information

Evaluating Fire- and Heat-Damaged Electrical Equipment

Evaluating Fire- and Heat-Damaged Electrical Equipment Evaluating Fire- and Heat-Damaged Electrical Equipment www.nema.org 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to heat

More information

Comprehensive Range of Industrial Products and Solutions

Comprehensive Range of Industrial Products and Solutions Comprehensive Range of Industrial Products and Solutions SAFETY AUTOMATION Micro Controllers Small Controllers Mid Range Controllers Large Automation Controllers Safety Programmable Controller Motion Controller

More information

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education

More information

Intertek Research & Performance Testing Technical Report S64604 Issue 1 Page 1 of 17. Report issued by: S64604 Issue 1

Intertek Research & Performance Testing Technical Report S64604 Issue 1 Page 1 of 17. Report issued by: S64604 Issue 1 Intertek Research & Performance Testing Technical Report S64604 Issue 1 Page 1 of 17 TECHNICAL REPORT Client: Stephen Curtler Electrical Safety Council 18 Buckingham Gate London SW1E 6LB Report issued

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Fire Protection Notice No. 9 ELECTRICAL SAFETY

Fire Protection Notice No. 9 ELECTRICAL SAFETY Fire Protection Notice No. 9 ELECTRICAL SAFETY Because electricity is one of the most controllable forms of energy it can also be one of the safest. But, as industry and commerce draw ever more heavily

More information

Transformers from 25va to 500kva. Standard despatch in days not weeks

Transformers from 25va to 500kva. Standard despatch in days not weeks Transformers from 25va to 500kva Standard despatch in days not weeks JMS Transformers Ltd 20 Ivatt Way Westwood Business Park Peterborough PE3 7PG UK Tel: +44 (0)1733 760000 Fax +44 (0)1733 760004 e-mail:

More information

Hazardous Locations Training

Hazardous Locations Training Hazardous Locations Training If you are involved with projects associated with hazardous locations, which involves the installation or inspection and maintenance of electrical or non-electrical e.g. mechanical;

More information

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV 1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled

More information

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Basic Security 101 Overview Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Components of an Alarm System Main Control

More information

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled. Methods of explosion protection for electrical equipment Flammable atmospheres can be ignited by sparks or not surfaces arising from the use of electrical power. Other possible sources of ignition are

More information

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS RESIDUAL CURRENT DEVICES

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS RESIDUAL CURRENT DEVICES 1 By kind permission of MK INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS RESIDUAL CURRENT DEVICES By Mark Coles The IEE receives many enquiries relating to the inspection and testing of electrical

More information

Building Services Engineering Technician

Building Services Engineering Technician Building Services Engineering Technician A competent Building Services Engineering Technician is expected to be able to demonstrate the following skills and competences: Systems design in the building

More information

Guide to the Selection & Use of Residual Current Devices

Guide to the Selection & Use of Residual Current Devices Guide to the Selection & Use of Residual Current Devices ET214:2005 Edition 1 Electro-Technical Council of Ireland Limited Published by the Electro-Technical Council of Ireland Limited Date of Publication:

More information

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation

More information

Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards

Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Abstract This Guide is an informative listing of selected terms and definitions found in IEC Glossary entry

More information

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Victor Lee Commercial Marketing Manager SEA Eaton Oil & Gas Solution Tech Day 2013 Eaton. All Rights Reserved. Eaton is a leading

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS 01. SAFETY INSPECTION of service equipment at FPL Power Source 02. Construction GFI power outlets (Temp Pole for Construction) 03. 90 day temporary power

More information

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens.

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany. www.siemens. Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c 91052 Erlangen Germany www.siemens.com/energy For questions on power transmission and distribution, please contact

More information

CONSULTATION PAPER FOR PROPOSED MODIFICATIONS TO THE TRANSMISSION CODE

CONSULTATION PAPER FOR PROPOSED MODIFICATIONS TO THE TRANSMISSION CODE CONSULTATION PAPER FOR PROPOSED MODIFICATIONS TO THE TRANSMISSION CODE Closing date for submission of representations: 30 th Sep 2014, 5 pm 18 AUG 2014 ENERGY MARKET AUTHORITY 991G Alexandra Road #01-29

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Screened cable and data cable segregation

Screened cable and data cable segregation December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;

More information

Comparative study for cables and busbars

Comparative study for cables and busbars Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary

More information

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One

More information

understanding medium frequency induction melting furnace and its components

understanding medium frequency induction melting furnace and its components understanding medium frequency induction melting furnace and its components 9 Spruce Street, Jersey City, NJ 07306 USA sales@electroheatinduction.com INDUCTION MELTING FURNACE AND ITS COMPONENTS The purpose

More information

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance Annex I To Loughborough University (LU) Facilities Management (FM) Health and Safety Policy High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance 1. Introduction a. These Safety

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT

TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of

More information

Electrical Resistance Resistance (R)

Electrical Resistance Resistance (R) Electrical Resistance Resistance (R) Any device in a circuit which converts electrical energy into some other form impedes the current. The device which converts electrical energy to heat energy is termed

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

Electrical Practices for Construction Work

Electrical Practices for Construction Work 1. Purpose Electrical Practices for Construction Work The purpose of this Code is to provide practical guidance and set minimum safety requirements for electrical practices on all construction sites in

More information

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

PROTECTION AGAINST ELECTRIC SHOCK by John Ware 16 become live under fault conditions. The potential of the metal enclosure is higher than that of the main earthing terminal of the installation (and that of Earth) because of a potential difference created

More information

Challenges to Ensure Safety of Electronic Equipment

Challenges to Ensure Safety of Electronic Equipment Challenges to Ensure Safety of Electronic Equipment (Malaysia s Perspective) Ir Abdul Rahim Ibrahim Director of Electrical Safety Regulation Energy Commission, Malaysia Content Electrical vs Electronic

More information

MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing

MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing Release: 1 MEM10019 Select circuit protection devices by type and rating, fit to switchboards and

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time Trial Exams C Standards and Regulations Examination No: GH-08-C- This test is intended to gauge your knowledge of essential information contained within AS/CA S009:2013. To qualify for an allpication to

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

Solar Panel Installations

Solar Panel Installations Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.

More information

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Power supply unit Model: PAC-SC50KUA

Power supply unit Model: PAC-SC50KUA Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.

More information