1 D5000 / D00 SERIES SAFETY RELAYS SERIES High Integrity Safety Relays Suitable for applications according to IEC 608 and IEC 611 Relays technology for safety DTS

2 SAFETY RELAY - FEATURES SAFETY RELAY SERIES FEATURESEATURES Applications When loads, such as valves or motors, cannot be driven directly by a safety or by an emergency push button, an interposing relay becomes a necessity. In example, when the power required to switch the load is greater than what can be provided by the or when multiple contacts are required to be driven by the same signal, the use of a relay is a must. In today s high integrity applications a standard relay is no longer acceptable. Whether it is for a ESD, F&G, BMS or for any other critical application, a Safety () Relay must be used. GMI Relays are available in various contact configurations and rating to cover the majority of applications; they are available with standard DC as well as with AC coil. Typical applications are shut down or relief valves control, Fire & Gas valve control, Turbine shut down motors, etc. For each application the specific Safety Function must be determined to select the correct Safety Relay. The Safety Function controls the operating condition of the SIF, therefore of the Safety Relay. Safety Functions can be basically divided in four types starting from the following operating conditions: Relay Coil - NC Relay Contacts ( Normally Energized ) Relay Coil - NO Relay Contacts ( Normally De-Energized ) ND Relay Coil - NO Relay Contacts ( Normally De-Energized ) ND Relay Coil - NC Relay Contacts ( Normally Energized ) By Relay Coil we mean a High condition (power on) at the relay coil terminals and by ND Relay Coil we mean the exact opposite, a Low condition (power off). NC or NO Relay Contacts determine whether power is available to the load under normal operating conditions or not; with NC contacts the load is Normally Energized and with NO contacts the load is Normally De-Energized. The Safety Function is to revert the above operating conditions. For example, with relay coil and NC relay contacts, Safety Function is to disconnect power to the load by removing power at the relay coil (From High to Low condition); This is the most typical relay function for a. Or, with a relay coil and NO relay contacts, Safety Function is to power-on load by removing power at the relay coil (From High to Low condition). Other aspects in selecting the safety relay are: the load s contacts rating; the number of contacts required to be driven by the same control signal; if a single line or both lines of the load must be switched ON or OFF. For each GMI Safety Relay a data sheet containing schematics of all possible applications, as well as coil and contacts rating, is available. Line Monitoring Some critical applications, such as ND systems (F&G), require constant monitoring of the line and load. When using a relay, it is no longer possible to use the Safety System inherent pulse or continuous monitoring feature to accomplish this task. Models D5293S, D5294S and D93S have a built-in diagnostic circuit that monitors line and load providing separate alarms. All units are designed to filter the safety system line monitoring pulse, thus eliminating negative effects for relay and load. Such feature can be switched ON or OFF in the field. 28 DTS

3 SAFETY RELAY - FEATURES Enclosure Characteristics Two types of enclosure are available in 12 or mm widths. D5000 Series 12 or mm; D00 Series mm. Plug-in screw terminal blocks to secure terminations up to 2.5 mm 2. DIP switches easily accessible by removing the side cover (D5000 series) or by sliding out the top part of the enclosure (D00 Series). Power Bus mounting Safety Relays equipped with Line and diagnostic require a supply source to operate. The power source can be connected through the unit s terminal blocks or via the optional power bus system available for both Series. Termination Board compatibility As for all modules of series D5000 and D00, Safety Relays can be installed on Customized Termination Boards. Available both for 12mm and mm modules. technology for safety DTS

4 SAFETY RELAY SELECTION TABLE Field device Model Connections Connections Rating SIL level D5090S +/AC -/AC ON +/AC -/AC ON 4 A 250 Vac 00 VA 4 A 250 Vdc 1 W Relay with Coil and (1-1). function: disconnect by disconnecting input (0-0). Can be used to disconnect one or both supply lines (see figures). Coil D5091S OFF ON 4 A 250 Vac 00 VA 4 A 250 Vdc 1 W SAFETY RELAYS D5290S Relay with ND Coil and ND or (0-0 or 0-1). function: connect by connecting input (1-1) or disconnect by connecting input (1-0) (see figures). To disconnect both supply lines, use two D5091S units in parallel. +/AC -/AC ON +/AC -/AC ON Coil A 250 Vac 2500 VA A 250 Vdc 300 W Relay with Coil and (1-1). function: disconnect by disconnecting input (0-0). Can be used to disconnect one or both supply lines (see figures). Coil D5291S OFF ON A 250 Vac 2500 VA A 250 Vdc 300 W Relay with ND Coil and ND or (0-0 or 0-1). function: connect by connecting input (1-1) or disconnect by connecting input (1-0) (see figures). To disconnect both supply lines, use two D5291S units in parallel. Coil 30 DTS

5 SAFETY RELAY SELECTION TABLE Field device Model Connections Connections Rating SIL level D5290S /SA +/AC -/AC ON +/AC -/AC ON A 250 Vac 2500 VA A 250 Vdc 300 W Relay with Coil and (1-1). function: disconnect by disconnecting input (0-0). Can be used to disconnect one or both supply lines (see figures). Installation in safe area only and not compatible with pulse diagnostic. Coil D5290S /AC -/AC A ON B +/AC -/AC A ON B 5 A 250 Vac 1250 VA 5 A 250 Vdc 175 W SAFETY RELAYS D5290S -079 Relay for /ND with /ND Coil for interrupting up to 4 loads. function: configurable via external wiring. Can be used to disconnect one or both supply lines (see data sheet). +/AC -/AC A ON B +/AC -/AC A ON B Coil 5 A 250 Vac 1250 VA 5 A 250 Vdc 175 W Relay for /ND with /ND Coil for interrupting up to 4 loads. function: configurable via external wiring. AC Coil. Can be used to disconnect one or both supply lines (see data sheet). 1 Vac Coil D5290S /AC -/AC ON +/AC -/AC ON A 250 Vac 2500 VA A 250 Vdc 300 W Relay with Coil and (1-1). AC Coil. function: disconnect by disconnecting input (0-0). Can be used to disconnect one or both supply lines (see figures). 1 Vac Coil technology for safety DTS

6 SAFETY RELAY SELECTION TABLE Field device Model Contacts Connections Rating SIL level D5293S ON OFF A 250 Vac 2500 VA A 250 Vdc 300 W Relay with Coil and (1-1). function: disconnect by disconnecting input (0-0). Can be used to disconnect both supply lines (see figures). With smart line and load diagnostic function. RS-485 output. Coil D5294S ON OFF A 250 Vac 2500 VA A 250 Vdc 300 W SAFETY RELAYS D92S Relay with ND Coil and (0-0). function: connect by connecting input (1-1). Can be used to disconnect both supply lines (see figures). With smart line and load diagnostic function. RS-485 output. ON OFF Coil 3 A 250 Vac 750 VA 3 A 125 Vdc 1 W Relay with and ND Coil and (1-1, 0-0). function : disconnect by disconnecting input (0-0). function ND: connect by connecting input (1-1). Coil D92D ON ON Dual channel Relay with and ND Coil and (1-1, 0-0). function : disconnect by disconnecting input (0-0). function ND: connect by connecting input (1-1). Can be used to disconnect two loads or both supply lines. ON 3 A 250 Vac 750 VA 3 A 125 Vdc 1 W Coil 32 DTS

7 SAFETY RELAY SELECTION TABLE Field device Model Contacts Connections Rating SIL level D92S -069 ON OFF 3 A 250 Vac 750 VA 3 A 125 Vdc 1 W Relay with Coil and (1-1) and ND Coil and (0-1). function : disconnect by disconnecting input (0-0). function ND: disconnect by connecting input (1-0). Coil SAFETY RELAYS D92D -069 ON ON Relay with Coil and (1-1) and ND Coil and (0-1). function : disconnect by disconnecting input (0-0). function ND: disconnect by connecting input (1-0). Can be used to disconnect two loads or both supply lines. ON 3 A 250 Vac 750 VA 3 A 125 Vdc 1 W Coil D93S ON OFF 3 A 250 Vac 750 VA 3 A 125 Vdc 1 W Dual channel Relay with and ND Coil and (1-1, 0-0). function : disconnect by disconnecting input (0-0). function ND: connect by connecting input (1-1). With line and load diagnostic function. Coil Safety Relay technology for safety DTS

8 Characteristics: Front Panel and Features: Ordering Information: D5090 General Description: The single channel Relay, D5090S is a relay module suitable for the switching of safety related circuits, up to level according to IEC 608 for high risk industries. It provides isolation between input and output contacts. Three mutually exclusive (by DIP-Switch programming) monitoring circuits are provided: 1) line input monitoring, to allow DCS/ line monitoring function: when enabled, the module permits a wide compatibility towards different DCS/. Driving line pulse testing, executed by DCS/, is permitted by a dedicated internal circuit, to prevent relay and LED flickering. 2) low voltage input monitoring: when enabled, the module reflects a high impedance state to the control unit when the driving voltage is below the specified threshold. 3) short circuit fault detection: when enabled, it allows DCS/ to detect short circuit fault of module. D5090S provides two NO contacts for normally energized load and a NC contact for service purpose, in order to switch the load on both supply lines. See the following pages for Functional Safety applications with related SIL value. Mounting on standard DIN-Rail or on customized Termination Boards, in Safe Area or in Zone 2. STS 1 2 D Model: D5090S G.M. International DTS Page 1/4 according to IEC 608 for Tproof = / yrs ( / % of total SIF). SIL 2 according to IEC 608 for Tproof = yrs ( % of total SIF). PFDavg (1 year) 7.01 E-06, SFF % for. Installation in Zone 2. contact for load and contact for service purpose. Line input monitoring in-field DIP Switch selectable. Driving input voltage monitoring. Input/ isolation. EMC Compatibility to EN , EN , EN626-1, EN for safety system. ATEX, IECEx Certifications. DIN-Rail accessories: Cover and fix MCHP196 Simplified installation using standard DIN-Rail and plug-in terminal blocks or customized Termination Boards. 4 A Relay Module for DIN-Rail and Termination Board Model D5090S Technical Data: Input: nom (.6 to 27.6 Vdc) reverse polarity protected, ripple within voltage limits 5 Vpp. The following monitoring circuits are mutually exclusive: 1) Line input monitoring (DIP-Switch selectable): to allow DCS/ line monitoring function (pulse test). 2) Voltage monitoring (DIP-Switch selectable):.6 Vdc for normal operation, 17 Vdc reflects a high impedance ( ma consumption) to the control device. 3) Short circuit fault detection (DIP-Switch selectable): to allow DCS/ to detect short circuit fault of module. Current 24 V: 35 ma with relay energized and line input monitoring disabled, 45 ma with relay energized and line input monitoring enabled, typical. Power dissipation: 0.85 W with 24 V input voltage, relay energized and line input monitoring disabled, 1.1 W with 24 V input voltage, relay energized and line input monitoring enabled, typical. Isolation (Test Voltage): Input / All s 2.5 KV ; Out 1 / Out 2: 500V. : 1 voltage free SPDT relay contact identified with outputs: Out 1 (NO contact) terminals 7-11 and Out (NC contact) terminals 9-; 1 voltage free SPST relay contact identified with output Out 2 (NO contact) terminals Terminals 7-11 (Out 1) and 8-12 (Out 2) are open when relay is de-energized, closed in energized relay condition. load output (not SIL) at terminals 9- is normally close when relay is de-energized, open in energized relay condition. Contact material: Ag Alloy (Cd free). Contact rating: 4 A 250 Vac 00 VA, 4 A 250 Vdc 1 W (resistive load). DC breaking capacity: V (V) Resistive Mechanical / Electrical life: 5 * 6 / 3 * 4 operation, typical. Bounce time NO / NC contact: 3 / 8 ms, typical. Frequency response: Hz maximum. Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 04/8/CE EMC Directive. Environmental conditions: Operating: temperature limits - 40 to + 70 C, relative humidity 95 %, up to 55 C. Storage: temperature limits - 45 to + 80 C. Safety Description: ATEX: II 3G Ex na nc IIC T4 Gc IECEx: Ex na nc IIC T4 Gc non-sparking electrical equipment. -40 C Ta 70 C. Approvals: BVS ATEX E 1 conforms to EN60079-, IECEx BVS.0072 X conforms to IEC Russia according to GOST , R , R , R ExnAnCIICT4 X. Ukraine according to GOST , 782.0, 782.3, ExsIIT4 X. TUV Certificate No. C-IS , SIL 2 / conforms to IEC608. Mounting: T35 DIN-Rail according to EN500 or on customized Termination Board. Weight: about 1 g. Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm 2. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4 installation. Protection class: IP. Dimensions: Width 12.5 mm, Depth 123 mm, Height 1 mm. 4 I (A)

9 Image: Function Diagram: SAFE AREA, ZO 2 GROUP IIC T4 MODEL D5090S Out 1 (NO contact) Out Not SIL (NO2) 11 (CM1) 7 (CM1) 9 (NC1) In Out 2 (NO contact) (NO1) 8 (NO3) 12 Termination board connector See the following pages for Functional Safety applications with related SIL value. Relay contact shown in de-energized position. Terminals 7-11 and 8-12 are open; terminals 9- are closed. G.M. International DTS Page 2/4

10 Applications: Application D5090S - Normally Energized Condition () and Normally Energized Relay, with interruption of both load supply lines Normal state operation De-energized to trip operation Vdc Contacts 7-11 and 8-12: in normal operation relays are energized, contacts are closed, load is energized. Contact 9-: in normal operation relay is energized, contact is open, service load for load is de-energized. Contacts 7-11 and 8-12: the Safety Function is met when the relays are de-energized, contacts are open, load is de-energized. Contact 9-: in safe state the relay is de-energized, contact is closed, service load for load is energized. G.M. International DTS Page 3/4

11 Applications: Application D5090S - Normally Energized Condition () and Normally Energized Relay, with interruption of only one load supply line Normal state operation De-energized to trip operation Vdc 12 8 Contacts 7-11 and 8-12: in normal operation relays are energized, contacts are closed, load is energized. Contact 9-: in normal operation relay is energized, contact is open, service load for load is de-energized. Contacts 7-11 and 8-12: the Safety Function is met when the relays are de-energized, contacts are open, load is de-energized. Contact 9-: in safe state the relay is de-energized, contact is closed, service load for load is energized. G.M. International DTS Page 4/4

12 Characteristics: Front Panel and Features: Ordering Information: D5091 General Description: The single channel Relay, D5091S is a relay module suitable for the switching of safety related circuits, up to level according to IEC 608 for high risk industries. It provides isolation between input and output contacts. Two mutually exclusive (by DIP-Switch programming) monitoring circuits are provided: 1) line input monitoring, to allow DCS/ line monitoring function: when enabled, the module permits a wide compatibility towards different DCS/. Driving line pulse testing, executed by DCS/, is permitted by a dedicated internal circuit, to prevent relay and LED flickering. 2) low voltage input monitoring: when enabled, the module reflects a high impedance state to the control unit when the driving voltage is below the specified threshold. D5091S provides 1 SPDT contact for two different safety functions: 1) Safety Function for Normally De-Energized load (energized in fail safe state) is available at Terminal Blocks 7-8. The driving signal is normally low (0 Vdc), the relay is normally de-energized, contact is open and load is de-energized. The safety function is met when the driving signal is high (), the relay is energized, contact is closed and load is energized. At Terminal Blocks 9- is also available a service contact (for service load) with opposite (not SIL) function. 2) Safety Function for Normally De-Energized load (energized in fail safe state) is available at Terminal Blocks 9-. The driving signal is normally high (), the relay is normally energized, contact is open and load is de-energized. The safety function is met when the driving signal is low (0 Vdc), the relay is de-energized, contact is closed and load is energized. At Terminal Blocks 7-8 is also available a service contact (for service load) with opposite (not SIL) function. Mounting on standard DIN-Rail or on customized Termination Boards, in Safe Area or in Zone 2. STS 1 2 D Model: D5091S according to IEC 608 for Tproof = 6 / 12 yrs ( / % of total SIF) for ND load with ND relay (terminals 7-8). according to IEC 608 for Tproof = / yrs ( / % of total SIF) for ND load with relay (terminals 9-). SIL 2 according to IEC 608 for Tproof = yrs ( % of total SIF). PFDavg (1 year) 1.58 E-05, SFF 99. % for ND load with ND relay. PFDavg (1 year) 7.01 E-06, SFF % for ND load with relay. Installation in Zone 2. 1 SPDT contact for 2 different Safety Functions: 1) for ND load (energized in fail safe state) with ND relay condition (energized in fail safe state) 2) for ND load (energized in fail safe state) with relay condition (de-energized in fail safe state) Line input monitoring in-field DIP Switch selectable. Driving input voltage monitoring. Input/ isolation. EMC Compatibility to EN , EN , EN626-1, EN for safety system. ATEX, IECEx Certifications. Simplified installation using standard DIN-Rail and plug-in terminal blocks or customized Termination Boards. 4 A Relay Module for ND with ND or Relay condition DIN-Rail & Termination Board, Model D5091S Technical Data: Input: nom (.6 to 27.6 Vdc) reverse polarity protected, ripple within voltage limits 5 Vpp. The following monitoring circuits are mutually exclusive: 1) Line input monitoring (DIP-Switch selectable): to allow DCS/ line monitoring function (pulse test). 2) Voltage monitoring (DIP-Switch selectable):.6 Vdc for normal operation, 17 Vdc reflects a high impedance ( ma consumption) to the control device. Current 24 V: 35 ma with relay energized and line input monitoring disabled, 45 ma with relay energized and line input monitoring enabled, typical. Power dissipation: 0.85 W with 24 V input voltage, relay energized and line input monitoring disabled, 1.1 W with 24 V input voltage, relay energized and line input monitoring enabled, typical. Isolation (Test Voltage): Input/ 2.5 KV. : voltage free SPDT relay contact. Terminals 7-8, open when relay de-energized, close in energized condition. Terminals 9-, close when relay de-energized, open in energized condition. Contact material: Ag Alloy (Cd free). Contact rating: 4 A 250 Vac 00 VA, 4 A 250 Vdc 1 W (resistive load). DC breaking capacity: V (V) Resistive Mechanical / Electrical life: 5 * 6 / 3 * 4 operation, typical. Bounce time NO / NC contact: 3 / 8 ms, typical. Frequency response: Hz maximum. Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 04/8/CE EMC Directive. Environmental conditions: Operating: temperature limits - 40 to + 70 C, relative humidity 95 %, up to 55 C. Storage: temperature limits - 45 to + 80 C. Safety Description: ATEX: II 3G Ex na nc IIC T4 Gc IECEx: Ex na nc IIC T4 Gc non-sparking electrical equipment. -40 C Ta 70 C. Approvals: BVS ATEX E 1 conforms to EN60079-, IECEx BVS.0072 X conforms to IEC Russia according to GOST , R , R , R ExnAnCIICT4 X. Ukraine according to GOST , 782.0, 782.3, ExsIIT4 X. TUV Certificate No. C-IS , SIL 2 / conforms to IEC608. Mounting: T35 DIN-Rail according to EN500 or on customized Termination Board. Weight: about 1 g. Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm 2. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4 installation. Protection class: IP. Dimensions: Width 12.5 mm, Depth 123 mm, Height 1 mm. 4 I (A) DIN-Rail accessories: Cover and fix MCHP196 G.M. International DTS Page 1/4

13 Image: Function Diagram: SAFE AREA, ZO 2 GROUP IIC T4 MODEL D5091S In () SPDT Out ND 7-8 or Termination board connector Relay contact shown in de-energized position Terminals 7-8 open, terminals 9- close. Safety Function for ND load (energized in fail safe state) is available at terminal blocks 7-8; In this case, the Safety Function is met when the relay is energized (closed contact). Safety Function for ND load (energized in fail safe state) is available at terminal blocks 9-; In this case, the Safety Function is met when the relay is de-energized (closed contact). G.M. International DTS Page 2/4

14 Applications: Application for D5091S - SIL Normally De-Energized Condition (ND) and Normally De-Energized Relay Normal state operation Energized to trip operation 0 Vdc Contact 7-8: in normal operation the relay is de-energized, contact is open, load is de-energized Contact 9-: in normal operation the relay is de-energized, contact is closed, service load is energized. Contact 7-8: the Safety Function is met when the relay is energized, contact is closed, load is energized. Contact 9-: relay is energized, contact is open, service load is de-energized. Application for two D5091S - SIL Normally De-Energized Condition (ND) and Normally De-Energized Relay with one common driving signal from for the two relays Normal state operation Energized to trip operation Vdc Contacts 7-8: in normal operation relays are de-energized, contacts are open, load is de-energized Contacts 9-: in normal operation relays are de-energized, contacts are closed, service load is energized. Contacts 7-8: the Safety Function is met when the relays are energized, contacts are closed, load is energized. Contacts 9-: relays are energized, contacts are open, service load is de-energized. G.M. International DTS Page 3/4

15 Applications: Application for D5091S - SIL Normally De-Energized Condition (ND) and Normally Energized Relay Normal state operation De-energized to trip operation Vdc Contact 7-8: in normal operation the relay is energized, contact is closed, service load is energized Contact 9-: in normal operation the relay is energized, contact is open, load is de-energized. Contact 7-8: relay is de-energized, contact is open, service load is de-energized. Contact 9-: the Safety Function is met when the relay is de-energized, contact is closed, load is energized. Application for two D5091S - SIL Normally De-Energized Condition (ND) and Normally Energized Relay with common driving signal from for the two relays Normal state operation De-energized to trip operation Vdc Contacts 7-8: in normal operation relays are energized, contacts are closed, service load is energized Contacts 9-: in normal operation relays are energized, contacts are open, load is de-energized. Contacts 7-8: relays are de-energized, contacts are open, service load is de-energized. Contacts 9-: the Safety Function is met when the relays are de-energized, contacts are closed, load is energized. G.M. International DTS Page 4/4

16 Characteristics: D5290 General Description: The single channel Relay, D5290S is a relay module suitable for the switching of safety related circuits, up to level according to IEC 608 for high risk industries. It provides isolation between input channel and output contacts. Three mutually exclusive (by DIP-Switch programming) monitoring circuits are provided: 1) line input monitoring, to allow DCS/ line monitoring function: when enabled, the module permits a wide compatibility towards different DCS/. Driving line pulse testing, executed by DCS/, is permitted by a dedicated internal circuit, to prevent relay and LED flickering. 2) low voltage input monitoring: when enabled, the module reflects a high impedance state to the control unit when the driving voltage is below the specified threshold. 3) short circuit fault detection: when enabled, it allows DCS/ to detect short circuit fault of module. D5290S provides two NO contacts for normally energized load and a NC contact for service purpose, in order to switch the load on both supply lines. See the following pages for Functional Safety applications with related SIL value. Mounting on standard DIN-Rail or on customized Termination Boards, in Safe Area or in Zone 2. A Relay Module for DIN-Rail and Termination Board Model D5290S Technical Data: Input: nom (.6 to 27.6 Vdc) reverse polarity protected, ripple within voltage limits 5 Vpp. The following monitoring circuits are mutually exclusive: 1) Line input monitoring (DIP-Switch selectable): to allow DCS/ line monitoring function (pulse test). 2) Voltage monitoring (DIP-Switch selectable):.6 Vdc for normal operation, 17 Vdc reflects a high impedance ( ma consumption) to the control device. 3) Short circuit fault detection (DIP-Switch selectable): to allow DCS/ to detect short circuit fault of module. Current 24 V: 60 ma with relay energized, typical. Power dissipation: 1.5 W with 24 V input voltage, relay energized, typical. Isolation (Test Voltage): Input / All s: 2.5 KV ; Out 1 / Out 2: 500V. : 1 voltage free SPDT relay contact identified with outputs: Out 1 (NO contact) terminals - and Out (NC contact) terminals -; 1 voltage free SPST relay contact identified with output Out 2 (NO contact) terminals -. Terminals - (Out 1) and - (Out 2) are open when relay is de-energized, closed in energized relay condition. load output (not SIL) at terminals - is normally close when relay is de-energized, open in energized relay condition. Contact material: Ag Alloy (Cd free) or AgSnO2. Contact rating: A 250 Vac 2500 VA, A 250 Vdc 300 W (resistive load). DC breaking capacity: V (V) Front Panel and Features: Resistive D5290 Ordering Information: Model: STS D5290S according to IEC 608 for Tproof = / yrs ( / % of total SIF). SIL 2 according to IEC 608 for Tproof = yrs ( % of total SIF). PFDavg (1 year) 7.01 E-06, SFF % for. Installation in Zone 2. A contact for load and contact for service purpose. Line input monitoring in-field DIP Switch selectable. Driving input voltage monitoring. Input/ isolation. EMC Compatibility to EN , EN , EN626-1, EN for safety system. ATEX, IECEx Certifications. Simplified installation using standard DIN-Rail and plug-in terminal blocks or customized Termination Boards I (A) Mechanical / Electrical life: * 6 / 5 * 4 operation, typical. Bounce time NO / NC contact: 4 / 6 ms, typical. Frequency response: Hz maximum. Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 04/8/CE EMC Directive. Environmental conditions: Operating: temperature limits 40 to + 60 C, relative humidity 95 %, up to 55 C. Storage: temperature limits - 45 to + 80 C. Safety Description: ATEX: II 3G Ex na nc IIC T4 Gc IECEx: Ex na nc IIC T4 Gc non-sparking electrical equipment. -40 C Ta 60 C. Approvals: BVS ATEX E 1 conforms to EN60079-, IECEx BVS.0072 X conforms to IEC Russia according to GOST , R , R , R ExnAnCIICT4 X. Ukraine according to GOST , 782.0, 782.3, ExsIIT4 X. TUV Certificate No. C-IS , SIL 2 / conforms to IEC608. Mounting: T35 DIN-Rail according to EN500 or on customized Termination Board. Weight: about 5 g. Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm 2. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4 installation. Protection class: IP. Dimensions: Width.5 mm, Depth 123 mm, Height 1 mm. DIN-Rail accessories: Cover and fix MCHP196 G.M. International DTS Page 1/4

17 Image: Function Diagram: SAFE AREA, ZO 2 GROUP IIC T4 MODEL D5290S Out 1 (NO contact) Not SIL (NO2) (CM1) (NC1) In Out 2 (NO contact) (NO1) (NO3) Termination board connector See the following pages for Functional Safety applications with related SIL value. Relay contact shown in de-energized position. Terminals - and - are open; terminal - is closed. G.M. International DTS Page 2/4

18 Applications: Application D5290S - Normally Energized Condition () and Normally Energized Relay, with interruption of both load supply lines Normal state operation De-energized to trip operation 0 Vdc Contacts - and -: in normal operation relays are energized, contacts are closed, load is energized. Contact -: in normal operation relay is energized, contact is open, service load for load is de-energized. Contacts - and -: the Safety Function is met when the relays are de-energized, contacts are open, load is de-energized. Contact -: in safe state the relay is de-energized, contact is closed, service load for load is energized. G.M. International DTS Page 3/4

19 Applications: Application D5290S - Normally Energized Condition () and Normally Energized Relay, with interruption of only one load supply line Normal state operation De-energized to trip operation 0 Vdc Contacts - and -: in normal operation relays are energized, contacts are closed, load is energized. Contact -: in normal operation relay is energized, contact is open, service load for load is de-energized. Contacts - and -: the Safety Function is met when the relays are de-energized, contacts are open, load is de-energized. Contact -: in safe state the relay is de-energized, contact is closed, service load for load is energized. G.M. International DTS Page 4/4

20 Characteristics: Front Panel and Features: Ordering Information: D5291 General Description: The single channel Relay, D5291S is a relay module suitable for the switching of safety related circuits, up to level according to IEC 608 for high risk industries. It provides isolation between input and output contacts. Two mutually exclusive (by DIP-Switch programming) monitoring circuits are provided: 1) line input monitoring, to allow DCS/ line monitoring function: when enabled, the module permits a wide compatibility towards different DCS/. Driving line pulse testing, executed by DCS/, is permitted by a dedicated internal circuit, to prevent relay and LED flickering. 2) low voltage input monitoring: when enabled, the module reflects a high impedance state to the control unit when the driving voltage is below the specified threshold. D5291S provides 1 SPDT contact for two different safety functions: 1) Safety Function for Normally De-Energized load (energized in fail safe state) is available at Terminal Blocks -. The driving signal is normally low (0 Vdc), the relay is normally de-energized, contact is open and load is de-energized. The safety function is met when the driving signal is high (), the relay is energized, contact is closed and load is energized. At Terminal Blocks - is also available a service contact (for service load) with opposite (not SIL) function. 2) Safety Function for Normally De-Energized load (energized in fail safe state) is available at Terminal Blocks -. The driving signal is normally high (), the relay is normally energized, contact is open and load is de-energized. The safety function is met when the driving signal is low (0 Vdc), the relay is de-energized, contact is closed and load is energized. At Terminal Blocks - is also available a service contact (for service load) with opposite (not SIL) function. Mounting on standard DIN-Rail or on customized Termination Boards, in Safe Area or in Zone 2. STS D5291 according to IEC 608 for Tproof = 6 / 12 yrs ( / % of total SIF) for ND load with ND relay (terminals -). according to IEC 608 for Tproof = / yrs ( / % of total SIF) for ND load with relay (terminals -). SIL 2 according to IEC 608 for Tproof = yrs ( % of total SIF). PFDavg (1 year) 1.58 E-05, SFF 99. % for ND load with ND relay. PFDavg (1 year) 7.01 E-06, SFF % for ND load with relay. Installation in Zone 2. A SPDT contact for 2 different Safety Functions: 1) for ND load (energized in fail safe state) with ND relay condition (energized in fail safe state) 2) for ND load (energized in fail safe state) with relay condition (de-energized in fail safe state) Line input monitoring in-field DIP Switch selectable. Driving input voltage monitoring. Input/ isolation. EMC Compatibility to EN , EN , EN626-1, EN for safety system. ATEX, IECEx Certifications. Simplified installation using standard DIN-Rail and plug-in terminal blocks or customized Termination Boards. A Relay Module for ND with ND or Relay condition DIN-Rail & Termination Board, Model D5291S Technical Data: Input: nom (.6 to 27.6 Vdc) reverse polarity protected, ripple within voltage limits 5 Vpp. The following monitoring circuits are mutually exclusive: 1) Line input monitoring (DIP-Switch selectable): to allow DCS/ line monitoring function (pulse test). 2) Voltage monitoring (DIP-Switch selectable):.6 Vdc for normal operation, 17 Vdc reflects a high impedance ( ma consumption) to the control device. Current 24 V: 60 ma with relay energized, typical. Power dissipation: 1.5 W with 24 V input voltage and relay energized, typical. Isolation (Test Voltage): Input/ 2.5 KV. : voltage free SPDT relay contact. Terminals -, open when relay de-energized, close in energized condition. Terminals -, close when relay de-energized, open in energized condition. Contact material: Ag Alloy (Cd free) or AgSnO2. Contact rating: A 250 Vac 2500 VA, A 250 Vdc 300 W (resistive load). DC breaking capacity: V (V) Resistive I (A) Mechanical / Electrical life: * 6 / 5 * 4 operation, typical. Bounce time NO / NC contact: 4 / 6 ms, typical. Frequency response: Hz maximum. Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 04/8/CE EMC Directive. Environmental conditions: Operating: temperature limits - 40 to + 60 C, relative humidity 95 %, up to 55 C. Storage: temperature limits - 45 to + 80 C. Safety Description: ATEX: II 3G Ex na nc IIC T4 Gc IECEx: Ex na nc IIC T4 Gc non-sparking electrical equipment. -40 C Ta 60 C. Approvals: BVS ATEX E 1 conforms to EN60079-, IECEx BVS.0072 X conforms to IEC Russia according to GOST , R , R , R ExnAnCIICT4 X. Ukraine according to GOST , 782.0, 782.3, ExsIIT4 X. TUV Certificate No. C-IS , SIL 2 / conforms to IEC608. Mounting: T35 DIN-Rail according to EN500 or on customized Termination Board. Weight: about 5 g. Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm 2. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4 installation. Protection class: IP. Dimensions: Width.5 mm, Depth 123 mm, Height 1 mm. Model: D5291S DIN-Rail accessories: Cover and fix MCHP196 G.M. International DTS Page 1/4

21 Image: Function Diagram: SAFE AREA, ZO 2 GROUP IIC T4 MODEL D5291S In () SPDT Out ND - or Termination board connector Relay contact shown in de-energized position Terminals - open, terminals - close. Safety Function for ND load (energized in fail safe state) is available at terminal blocks -; In this case, the Safety Function is met when the relay is energized (closed contact). Safety Function for ND load (energized in fail safe state) is available at terminal blocks -; In this case, the Safety Function is met when the relay is de-energized (closed contact). G.M. International DTS Page 2/4

22 Applications: Application for D5291S - SIL Normally De-Energized Condition (ND) and Normally De-Energized Relay Normal state operation Energized to trip operation 0 Vdc Contact -: in normal operation the relay is de-energized, contact is open, load is de-energized Contact -: in normal operation the relay is de-energized, contact is closed, service load is energized. Contact -: the Safety Function is met when the relay is energized, contact is closed, load is energized. Contact -: relay is energized, contact is open, service load is de-energized. Application for two D5291S - SIL Normally De-Energized Condition (ND) and Normally De-Energized Relay with one common driving signal from for the two relays Normal state operation Energized to trip operation 0 Vdc Contacts -: in normal operation relays are de-energized, contacts are open, load is de-energized Contacts -: in normal operation relays are de-energized, contacts are closed, service load is energized. Contacts -: the Safety Function is met when the relays are energized, contacts are closed, load is energized. Contacts -: relays are energized, contacts are open, service load is de-energized. G.M. International DTS Page 3/4

23 Applications: Application for D5291S - SIL Normally De-Energized Condition (ND) and Normally Energized Relay Normal state operation De-energized to trip operation 0 Vdc Contact -: in normal operation the relay is energized, contact is closed, service load is energized Contact -: in normal operation the relay is energized, contact is open, load is de-energized. Contact -: relay is de-energized, contact is open, service load is de-energized. Contact -: the Safety Function is met when the relay is de-energized, contact is closed, load is energized. Application for two D5291S - SIL Normally De-Energized Condition (ND) and Normally Energized Relay with common driving signal from for the two relays Normal state operation De-energized to trip operation 0 Vdc Contacts -: in normal operation relays are energized, contacts are closed, service load is energized Contacts -: in normal operation relays are energized, contacts are open, load is de-energized. Contacts -: relays are de-energized, contacts are open, service load is de-energized. Contacts -: the Safety Function is met when the relays are de-energized, contacts are closed, load is energized. G.M. International DTS Page 4/4

24 Characteristics: D5290 /SA General Description: The single channel Relay, D5290S/SA is a relay module suitable for the switching of safety related circuits, up to level according to IEC 608 for high risk industries. It provides isolation between input and output contacts. D5290S/SA provides two NO contacts for normally energized load and a NC contact for service purpose, in order to switch the load on both supply lines. See the following pages for Functional Safety applications with related SIL value. Mounting on standard DIN-Rail in Safe Area. A Relay Module for DIN-Rail and Termination Board Model D5290S/SA for Safe Area only Technical Data: Input: nom (.6 to 27.6 Vdc) reverse polarity protected, ripple within voltage limits 5 Vpp. Current 24 V: 40 ma with relay energized, typical. Power dissipation: 1 W with 24 V input voltage, relay energized, typical. Isolation (Test Voltage): Input / All s 2.5 KV ; Out 1 / Out 2: 500 V. : 1 voltage free SPDT relay contact identified with outputs: Out 1 (NO contact) terminals - and Out (NC contact) terminals -; 1 voltage free SPST relay contact identified with output Out 2 (NO contact) terminals -. Terminals - (Out 1) and - (Out 2) are open when relay is de-energized, closed in energized relay condition. load output (not SIL) at terminals - is normally close when relay is de-energized, open in energized relay condition. Contact material: Ag Alloy (Cd free) or AgSnO2. Contact rating: A 250 Vac 2500 VA, A 250 Vdc 300 W (resistive load). DC breaking capacity: V (V) Resistive Front Panel and Features: according to IEC 608 for Tproof = / yrs ( / % of total SIF) I (A) STS D5290 /SA SIL 2 according to IEC 608 for Tproof = yrs ( % of total SIF). PFDavg (1 year) 7.01 E-06, SFF 99. % for. A contact for load and contact for service purpose. Input/ isolation. EMC Compatibility to EN , EN , EN626-1, EN for safety system. Simplified installation using standard DIN-Rail and plug-in terminal blocks or customized Termination Boards. Mechanical / Electrical life: * 6 / 5 * 4 operation, typical. Bounce time NO / NC contact: 4 / 6 ms, typical. Frequency response: Hz maximum. Compatibility: CE mark compliant, conforms to 04/8/CE EMC Directive. Environmental conditions: Operating: temperature limits 40 to + 70 C, relative humidity 95 %, up to 55 C. Storage: temperature limits - 45 to + 80 C. Approvals: conforms to IEC608. Mounting: T35 DIN-Rail according to EN500 or on customized Termination Board. Weight: about 5 g. Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm 2. Location: Safe Area installation. Protection class: IP. Dimensions: Width.5 mm, Depth 123 mm, Height 1 mm Ordering Information: Model: D5290S/SA DIN-Rail accessories: Cover and fix MCHP196 G.M. International DTS Page 1/4

25 Image: Function Diagram: SAFE AREA MODEL D5290S/SA Out 1 (NO contact) Not SIL (NO2) (CM1) (NC1) In Out 2 (NO contact) (NO1) (NO3) Termination board connector See the following pages for Functional Safety applications with related SIL value. Relay contact shown in de-energized position. Terminals - and - are open; terminal - is closed. G.M. International DTS Page 2/4

26 Applications: Application D5290S/SA - Normally Energized Condition () and Normally Energized Relay, with interruption of both load supply lines Normal state operation De-energized to trip operation 0 Vdc Contacts - and -: in normal operation relays are energized, contacts are closed, load is energized. Contact -: in normal operation relay is energized, contact is open, service load for load is de-energized. Contacts - and -: the Safety Function is met when the relays are de-energized, contacts are open, load is de-energized. Contact -: in safe state the relay is de-energized, contact is closed, service load for load is energized. G.M. International DTS Page 3/4

27 Applications: Application D5290S/SA - Normally Energized Condition () and Normally Energized Relay, with interruption of only one load supply line Normal state operation De-energized to trip operation 0 Vdc Contacts - and -: in normal operation relays are energized, contacts are closed, load is energized. Contact -: in normal operation relay is energized, contact is open, service load for load is de-energized. Contacts - and -: the Safety Function is met when the relays are de-energized, contacts are open, load is de-energized. Contact -: in safe state the relay is de-energized, contact is closed, service load for load is energized. G.M. International DTS Page 4/4

28 Characteristics: Front Panel and Features: D Ordering Information: Model: STS D General Description: The D5290S-078 is a relay module suitable for the switching of safety related circuits, up to level according to IEC 608 for high risk industries. It provides isolation between input channel and output contacts. Three mutually exclusive (by DIP-Switch programming) monitoring circuits are provided: 1) line input monitoring, to allow DCS/ line monitoring function: when enabled, the module permits a wide compatibility towards different DCS/. Driving line pulse testing, executed by DCS/, is permitted by a dedicated internal circuit, to prevent relay and LED flickering. 2) low voltage input monitoring: when enabled, the module reflects a high impedance state to the control unit when the driving voltage is below the specified threshold. 3) short circuit fault detection (only for Functional Safety applications with Relay condition): when enabled, it allows DCS/ to detect short circuit fault of module. See the following pages for Functional Safety applications with related SIL value. Mounting on standard DIN-Rail or on customized Termination Boards, in Safe Area or in Zone according to IEC 608 for Tproof = / years ( / % of total SIF) with PFDavg (1 year) 7.01 E-06, SFF = % for two or ND loads with relay condition (see application n 1, 2 and 4). SIL 2 according to IEC 608 for Tproof = 7 / years ( / % of total SIF) with PFDavg (1 year) 1.40 E-04, SFF = % for four loads with relay condition (see application n 3). according to IEC 608 for Tproof = 6 / 12 years ( / % of total SIF) with PFDavg (1 year) 1.58 E-05, SFF = 99. % for ND load with ND relay condition (see application n 5). SIL 2 according to IEC 608 for Tproof = yrs ( % or more of total SIF) with PFDavg (1 year) 1.54 E-05, SFF = % for two ND loads with ND relay condition (see application n 6). Installation in Zone 2. 5 A / SIL 2 contacts for or ND loads with or ND Relay condition. Line input monitoring in-field DIP Switch selectable. Driving input voltage monitoring. Input/ isolation. EMC Compatibility to EN , EN , EN626-1, EN for safety system. ATEX, IECEx Certifications. Simplified installation using standard DIN-Rail and plug-in terminal blocks or customized Termination Boards. D5290S A Relay Module for or ND s with or ND Relay condition DIN-Rail & Termination Board, Model D5290S-078 Technical Data: Input: nom (.6 to 27.6 Vdc) reverse polarity protected, ripple within voltage limits 5 Vpp. The following monitoring circuits are mutually exclusive: 1) Line input monitoring (DIP-Switch selectable): to allow DCS/ line monitoring function (pulse test). 2) Voltage monitoring (DIP-Switch selectable):.6 Vdc for normal operation, 17 Vdc reflects a high impedance ( ma consumption) to the control device. 3) Short circuit fault detection (DIP-Switch selectable and only for Functional Safety applications with Relay condition): to allow DCS/ to detect short circuit fault of module. Current 24 V: 60 ma with relay energized, typical. Power dissipation: 1.5 W with 24 V input voltage, relay energized, typical. Isolation (Test Voltage): Input / All s: 2.5 KV; Out S_1 & Out P_1 / Out S_3 & Out P_2, Out S_2, Out S_4: 500 V; Out S_3 & Out P_2 / Out S_2, Out S_4: 500 V; Out S_2 / Out S_4: 500 V. : 2 voltage free SPDT (= NO contact + parallel of 2 NC contacts) relay contacts identified with outputs: Out S_1 & Out P_1 and Out S_3 & Out P_2; 2 voltage free SPST (NO) relay contacts identified with: Out S_2 and Out S_4. Terminals - (Out S_1), - (Out S_2), - (Out S_4) and (Out S_3) are: open when relay is de-energized, closed in energized relay condition. Terminals (Out P_1) and 19- (Out P_2) are: closed when relay is de-energized, open in energized relay condition. Contact material: Ag Alloy (Cd free) or AgSnO2. Contact rating: 5 A 250 Vac 1250 VA, 5 A 250 Vdc 175 W (resistive load). DC breaking capacity: V (V) Resistive I (A) Mechanical / Electrical life: * 6 / 5 * 4 operation, typical. Bounce time NO / NC contact: 4 / ms, typical. Frequency response: Hz maximum. Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 04/8/CE EMC Directive. Environmental conditions: Operating: temperature limits - 40 to + 60 C, relative humidity 95 %, up to 55 C. Storage: temperature limits - 45 to + 80 C. Safety Description: ATEX: II 3G Ex na nc IIC T4 Gc IECEx: Ex na nc IIC T4 Gc non-sparking electrical equipment. -40 C Ta 60 C. Approvals: ATEX conforms to EN60079-, IECEx conforms to IEC SIL 2 / conforms to IEC608. Mounting: T35 DIN-Rail according to EN500 or on customized Termination Board. Weight: about 5 g. Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm 2. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4 installation. Protection class: IP. Dimensions: Width.5 mm, Depth 123 mm, Height 1 mm. 4 5 DIN-Rail accessories: Cover and fix MCHP196 G.M. International DTS Page 1/6 - PRELIMINARY INFORMATION

29 Image: Function Diagram: SAFE AREA, ZO 2 GROUP IIC T4 Out S_2 (NO contact) MODEL D5290S-078 Out P_1 (NC contact) Out S_1 (NO contact) Out S_3 (NO contact) Out P_2 (NC contact) In Out S_4 (NO contact) Termination board connector See the following pages for Functional Safety applications with related SIL value. Relay contacts shown in de-energized position. Terminals -, -, - and are open. Terminals and 19- are closed. PRELIMINARY INFORMATION - G.M. International DTS Page 2/6

30 Applications: 1) Application D5290S Normally Energized Condition () and Normally Energized Relay: one common driving signal from for both loads (A and B), with interruption of both load supply lines Normal state operation (for load A and its service load) (for load B and its service load) De-energized to trip operation (for load A and its service load) (for load B and its service load) A B A 0 Vdc B (for load A and its service load) (for load B and its service load) Contacts - and -: in normal operation relays are energized, contacts are closed, load (A) is energized. Contact (double contact in parallel): in normal operation relay is energized, contact is open, service load for load (A) is de-energized. (for load A and its service load) (for load B and its service load) Contacts - and -: the Safety Function is met when the relays are de-energized, contacts are open, load (A) is de-energized. Contact (double contact in parallel): in safe state the relay is de-energized, contact is closed, service load for load (A) is energized. Contacts - and 23-24: in normal operation relays are energized, contacts are closed, load (B) is energized. Contact 19- (double contact in parallel): in normal operation relay is energized, contact is open, service load for load (B) is de-energized. Contacts - and 23-24: the Safety Function is met when the relays are de-energized, contacts are open, load (B) is de-energized. Contact 19- (double contact in parallel): in safe state the relay is de-energized, contact is closed, service load for load (B) is energized. Warning: being an application with Relay condition, if DCS/ is set to monitor the input line current, it s appropriate to enable the short circuit fault detection so that DCS/ can detect short circuit fault of module (as, for example, the short circuit of a relay coil). 2) Application D5290S Normally Energized Condition () and Normally Energized Relay: one common driving signal from for both loads (A and B), with interruption of only one load supply line Normal state operation De-energized to trip operation (for load A and its service load) (for load B and its service load) (for load A and its service load) (for load B and its service load) Vdc A B A B (for load A and its service load) (for load B and its service load) (for load A and its service load) (for load B and its service load) Contacts - and -: in normal operation relays are energized, contacts are closed, load (A) is energized. Contact (double contact in parallel): in normal operation relay is energized, contact is open, service load for load (A) is de-energized. Contacts - and 23-24: in normal operation relays are energized, contacts are closed, load (B) is energized. Contact 19- (double contact in parallel): in normal operation relay is energized, contact is open, service load for load (B) is de-energized. Contacts - and -: the Safety Function is met when the relays are de-energized, contacts are open, load (A) is de-energized. Contact (double contact in parallel): in safe state the relay is de-energized, contact is closed, service load for load (A) is energized. Contacts - and 23-24: the Safety Function is met when the relays are de-energized, contacts are open, load (B) is de-energized. Contact 19- (double contact in parallel): in safe state the relay is de-energized, contact is closed, service load for load (B) is energized. Warning: being an application with Relay condition, if DCS/ is set to monitor the input line current, it s appropriate to enable the short circuit fault detection so that DCS/ can detect short circuit fault of module (as, for example, the short circuit of a relay coil). G.M. International DTS Page 3/6 - PRELIMINARY INFORMATION

Single Channel Speed Monitor for Rotating Equipment with SIL2 requirements Series E16521D.3

Single Channel Speed Monitor for Rotating Equipment with SIL2 requirements Series E16521D.3 E16 Single Channel Speed Monitor for Rotating Equipment with SIL2 requirements Series Front View KEY FEATURES SIL2 / IEC 61508:2010 compliant Single Channel Monitor with sensor monitoring and self-test

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Assembly. Front view. Switch S1. Power Rail

Assembly. Front view. Switch S1. Power Rail Temperature Repeater Features Assembly 1-channel isolated barrier V DC supply (Power Rail) Resistance and RTD input (Pt100, Pt500, Pt1000) Resistance output Accuracy 0.1 % Line fault detection (LFD) for

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

S-series Mass Connection Solutions

S-series Mass Connection Solutions DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

Monitor for Measurement of Speed and Detection of Direction Series D224.xxS2

Monitor for Measurement of Speed and Detection of Direction Series D224.xxS2 D Monitor for Measurement of Speed and Detection of Series D.xxS KEY FEATURES Speed and Monitor with sensor monitoring and self-test function Frequency range 0 Hz 00 khz Analog Output 0/ 0 ma Bright red

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications AE8-1328 R5 March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the Copeland

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring 3500/15 Power Supply Bently Nevada* Asset Condition Monitoring Description The 3500 Power Supplies are half-height modules and must be installed in the specially designed slots on the left side of the

More information

Safety Manual BT50(T) Safety relay / Expansion relay

Safety Manual BT50(T) Safety relay / Expansion relay Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

3500/25 Enhanced Keyphasor*Module

3500/25 Enhanced Keyphasor*Module 3500/25 Enhanced Keyphasor*Module Bently Nevada* Asset Condition Monitoring Description The 3500/25 Enhanced Keyphasor Module is a half-height, two-channel module used to provide Keyphasor signals to the

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters Characteristics voltage control relay RM17-U - range 65..260 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

T M. IRDH275 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 08.

T M. IRDH275 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 08. T M 1 IRDH275 Series Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012021 / 08.2013 IRDH275 Series Digital ground fault monitor / ground

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

COMPALARM C2C ALARM SYSTEM

COMPALARM C2C ALARM SYSTEM INSTRUCTION MANUAL IM670-U v0.1 COMPALARM C2C ALARM SYSTEM GENERAL Compact alarm system, with a basic module of 12 signals Multiple modules coupling possibility Easy printing of the alarm points description

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

Circuit diagram. Inteded use. Function

Circuit diagram. Inteded use. Function SNA 4043 K SNA 4063 K SNA 4044 K SNA 4064 K Basic unit for emergency stop and guard door applications Basic unit as per EN 62061 and EN ISO 13849-1 For safety category 4 and stop category 0 Single or twin

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

VALVES ISO 5599/1 SERIES SAFE AIR

VALVES ISO 5599/1 SERIES SAFE AIR Starting from a series of sturdy, reliable valves, such as those to ISO 5599/1, some special features have been added, such as the presence of a valve status diagnostic system and the creation of a double

More information

Controller for temperature control EKC 201 and EKC 301 REFRIGERATION AND AIR CONDITIONING. Technical Brochure

Controller for temperature control EKC 201 and EKC 301 REFRIGERATION AND AIR CONDITIONING. Technical Brochure Controller for temperature control EKC 201 and EKC 301 REFRIGERATION AND AIR CONDITIONING Technical Brochure Introduction EKC 201 (for panel mounting) and EKC 301 (for DIN-rail mounting) have been specially

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

MINI MCR-SL-UI-UI-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-UI-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-UI-NC Order No.: 2864150 MCR 3-way isolating amplifier for electrical isolation of analog signals, input/output configurable via DIP switch, with screw connection,

More information

SAFETY MANUAL SIL RELAY MODULE

SAFETY MANUAL SIL RELAY MODULE PROCESS AUTOMATION SAFETY MANUAL SIL RELAY MODULE KFD0-RSH-1.4S.PS2 ISO9001 3 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

NX safety stand-alone

NX safety stand-alone NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O

More information

RHINO PSM Series Power Supplies

RHINO PSM Series Power Supplies RHINO PSM Series Supplies Our versatile switching power supplies are DIN-rail mountable Features Industrial grade design Sturdy metal case to withstand harsh industrial environments Model PSM4-090S-N meets

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

DLP-PU/E Instruction Manual

DLP-PU/E Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

3500/93 System Display

3500/93 System Display 3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide

More information

Technical Description

Technical Description abcxyz Contents 1. General...1 2. Block Diagram...2 3. First Steps...2 4. Technical Data...3 4.1 AS-Interface...3 4.2 Pin Out...4 4.3 Supply of Periphery...4 4.4 Inputs...5 4.5 Outputs...5 4.6 Mechanical

More information

Electronic Circuit Breaker ESS20-0...

Electronic Circuit Breaker ESS20-0... Description Electronic circuit breaker type ESS0-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern

More information

Ametek, Inc. Rotron Technical Products Division. 627 Lake Street Kent, Ohio User's Guide. Number Revision E

Ametek, Inc. Rotron Technical Products Division. 627 Lake Street Kent, Ohio User's Guide. Number Revision E Ametek, Rotron Technical Products Division 627 Lake Street Kent, Ohio 44240 User's Guide 120 Volt, 800 Watt and 240 Volt, 1200 Watt Brushless Motor Drive Electronics 5.7" (145 mm) and 7.2" (183 mm) Windjammer

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

SYNCHROTACT CSS Synchronizing system for synchronous generators

SYNCHROTACT CSS Synchronizing system for synchronous generators SYNCHROTACT CSS Synchronizing system for synchronous generators Application Reliable synchronizing and paralleling SYNCHROTACT CSS (compact synchronizing system) is a combination system to parallel power

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm. Short-circuit protection

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm. Short-circuit protection 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Multi-Channel Programmable DC Power Supplies

Multi-Channel Programmable DC Power Supplies Dual and triple output models with two 30V/1.5A (45W) channels and a 6V/5A (30W) channel on the triple output supply All channels are independently controlled and have isolated outputs for maximum flexibility

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

USB-ERB08 Specifications

USB-ERB08 Specifications USB-ERB08 Specifications Document Revision 1.4, April, 2016 Copyright 2016, Measurement Computing Corporation All specifications are subject to change without notice. Typical for 25 C unless otherwise

More information

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Switching Power Supply Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Models range from 10 W to 600 W Wide range of output voltages: 5 V, 12 V, 15 V, or 24 V UL, CSA, VDE,

More information

Binary input 520BID01 Data sheet

Binary input 520BID01 Data sheet RTU520 product line Binary input 520BID01 Data sheet The module is available in two versions (rubrics): 520BID01 R0001: process voltage 24 to 60 V DC. LED signaling for each input, common return per 8

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Solid State Timers Type F

Solid State Timers Type F Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20 Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC Characteristics on-delay timing relay - 0.05..1 s - 24 V AC DC - 1OC Main Commercial Status Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

3500/22M Transient Data Interface

3500/22M Transient Data Interface 3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Moxa PoE Injector. INJ-24 Series. Hardware Installation Guide. Second Edition, March Moxa Inc. All rights reserved. P/N:

Moxa PoE Injector. INJ-24 Series. Hardware Installation Guide. Second Edition, March Moxa Inc. All rights reserved. P/N: Moxa PoE Injector INJ-24 Series Hardware Installation Guide Second Edition, March 2011 2011 Moxa Inc. All rights reserved. P/N: 1802000240011 Overview The Moxa PoE Injector INJ-24 Series is a 1-port PoE

More information

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AC3200 INTELLIGENT BROADBAND AMPLIFIER Kari Mäki 12.11.2009 1(8) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information