DIGITAL MULTIMETER INSTRUCTIONS IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL.
|
|
- Abigayle Cain
- 7 years ago
- Views:
Transcription
1 DIGITAL MULTIMETER STOCK No PART No.DMM10 INSTRUCTIONS IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL. 05/2001
2 INTRODUCTION Digital Multimeter This multimeter is ideal for general electrical and automotive use. FEATURES 32 position rotary function and range selector. Recessed input terminals for added safety. Measures A.C./D.C. voltage, A.C./D.C. amps, frequency, temperature, resistance and capacitance. 200mA fuse protection. Audible continuity buzzer. Diode test facility. Hi-impact rubber case with integral stands. Supplied with test leads, probes and battery. SPECIFICATION D.C.Voltage: 200mV, 2V, 20V, 200V (accuracy +/- 0.5% of rdg. +/- 1 digit). 1000V (accuracy +/- 0.8% of rdg. +/- 2 digits). A.C.Voltage: 2V, 20V, 200V, (accuracy +/- 0.8% of rdg. +/- 3 digits). 700V, (accuracy +/- 1.2% of rdg. +/- 3 digits). D.C. Amps: 2mA, 20mA, (accuracy +/- 0.8% of rdg. +/- 1 digit). 200mA (accuracy +/- 1.5% of rdg. +/- 1 digit). 10A, (accuracy +/- 2.0% of rdg. +/- 5 digits). A.C. Amps: 20mA (accuracy +/- 1.0% of rdg. +/- 3 digits). 200mA (accuracy +/- 1.8% of rdg. +/- 3 digits). 10A (accuracy +/- 3.0% of rdg. +/- 7 digits). Resistance: 200Ω, (accuracy +/- 0.8% of rdg. +/- 3 digits). 2KΩ, 20KΩ, 200KΩ,2MΩ, (accuracy +/- 0.8% of rdg. +/- 1 digit). 20MΩ, (accuracy +/- 1.0% of rdg. +/- 2 digits). 200MΩ, (accuracy +/- 5.0% of rdg. +/- 10 digits). Frequency: 20KHz (accuracy +/- 1.5% of rdg. +/- 5 digits). Temperature: -20ºC to 0ºC, (accuracy +/- 5.0% of rdg. +/- 4 digits). 0ºC to 400ºC, (accuracy +/- 1.0% of rdg. +/- 3 digits). 400ºC to 1000ºC, (accuracy +/- 2.0% of rdg.) Capacitance: 2nF, 20nf, 200nF, 2µF, 20µF, (accuracy +/- 4.0% of rdg. +/- 3 digits). WARNING: To avoid electric shock remove test leads before opening cover. To prevent risk of fire use only the correct fuse as shown on the rear cover of the meter. (Fuse is bypassed on 20A setting, ensure you refer to point 5 and 6 on page 3). - 1-
3 Fig 1. MAINTENANCE The fuse rarely needs replacing, and almost always, a blown fuse is the result of operator error. (see warning on front page). If the meter battery is in need of replacement, will appear on the display. ACCESSORIES PART No: YDMM10 STOCK No: DESCRIPTION: Multimeter Crocodile clip and Probe Set. PART No: YDMM10 STOCK No: DESCRIPTION: Spare Probe Set
4 KNOW YOUR MULTIMETER - 3-
5 KNOW YOUR MULTIMETER 1. Function and Range Selector Switch This switch is used to select the function and desired range. 2. Display LCD display unit. 3. COM Jack Socket Plug in the black (negative) test lead. 4. V/Ω/Hz (voltage/resistance/hertz) Jack Socket (max 200mA) Plug in the red (positive) test lead for all voltage, resistance and amperage (max 200mA) measurements A Jack socket (max 20A) Plug in the red (positive) test lead for measuring amperage from a minimum of 200mA to a maximum of 20A. 6. Transistor Test Socket Suitable for both NPN and PNP transistors. 7. Temperature Measuring Socket Plug in the thermocouple adaptor provided to measure temperatures between -20ºC to 1000ºC. 8. Capacitor Measuring Socket Insert capacitors directly into testing sockets. Measuring range of 2nF to 2µF. OTHER METER MARKINGS/READINGS Diode or continuity test modes have been selected. Caution (see note 5 above and warning on page 1). Indicates that the meter battery voltage has dropped excessively. Caution, risk of electric shock. µa,ma,a Units for current measurements. ACV AC Voltage ranges. mv,v Units for voltage measurements. DCV DC Voltage ranges. Ω,KΩ,MΩ Units for resistance measurements. DCA DC Current ranges. Indicates low battery. OHM Resistance ranges. - 4-
6 OPERATION WARNINGS: Before you use the instrument, inspect the test leads, connectors and probes for damage e.g. cracks or breaks in the insulation. Replace any defective leads before use. If the voltage to be measured is not known, set the selector switch to the highest range and reduce until a satisfactory reading is obtained. DC Voltage Measurement 2. Set the selector switch to the desired D.C.V. range. 3. Connect the test leads to the circuit to be measured. 4. Turn on the power to the circuit to be measured, the voltage value should appear on the digital display along with the voltage polarity (if reversed only). AC Voltage Measurement 2. Set the selector switch to the desired A.C.V. range. 3. Connect the test leads to the circuit to be measured. 4. Turn on the power to the circuit to be measured. The voltage value will appear on the digital display. AC/DC Current Measurement 1. Connect the red test lead to the ma or A jack socket and the black lead to the COM (For measurements between 200mA and 10A connect the red test lead to the A socket. (Max. 20A). 2. Set the selector switch to the desired A.C./D.C. range. 3. Open the circuit to be measured and connect the test leads IN SERIES with the load in which current is to be measured. (See Fig. 1) on page Turn on the power to the circuit to be measured. The AMPERAGE value should appear on the digital display. Resistance Measurement 2. Set the selector switch to the desired OHM range. 3. WARNING: if the resistance to be measured is part of a circuit, turn off the power and discharge all capacitors before measurement. If the reading is less than 200Ω, the display will show 1MΩ, this figure should be subtracted from measurement results. 4. Connect the test leads to the circuit to be measured. 5. The resistance value should now appear on the digital display
7 Diode Measurement jack socket. 2. Set the selector switch to the position. 3. Connect the red test lead to the anode of the diode to be measured and the black test lead to the cathode. 4. The forward voltage drop in mv will be displayed. If the diode is reversed, the figure 1 should show on the display. Transistor hfe Test 1. Set the selector switch to the hfe position. 2. Determine whether the transistor is NPN or PNP. 3. Locate the emitter (E), base (B) and collect (C) legs into the correct holes in the socket on the front panel. 4. The display will read the approximate hfe value at the test condition of base current 10µA VCE 3.2V. Frequency measurement 2. Set the selector switch to the 20K/Hz position. 3. Connect the test leads to the circuit/source to be measured. 4. The frequency value should now be displayed on the digital display. Note: Readings can be taken from input voltages above 10Vms, but the accuracy is not guaranteed. In noisy environment, it is recommended that shielded cables are used for measuring small signals. Capacitance Measurement 1. Set the selector switch to the desired setting within the F range (20nF to 20µF). 2. Before testing the capacitor in the capacitance measuring socket, be sure that the capacitor has been fully discharged. 3. Once the capacitor has been placed into the testing sockets, the capacitance value will be displayed on the digital display. Continuity Test 2. Set the selector switch to the position. 3. Connect the test leads to the circuit/source to be measured. 4. If continuity exists (i.e. resistance is less than 50Ω) the audible buzzer will sound. Temperature Measurement 1. Set the selector switch to the ºC position. The digital display will show the current environment temperature. 2. Insert the thermocouple plug provided into the temperature measuring socket, but remember to remove it before selecting another function to avoid the risk of an electric shock. 3. Contact the object to be measured with the thermocouple probe. 4. The temperature value will be displayed on the digital display. - 6-
8 DRAPER TOOLS LIMITED, Hursley Road, Chandler's Ford, Eastleigh, Hants. SO53 1YF. U.K. Helpline: (023) Sales Desk: (023) General Enquiries: (023) Fax: (023) YOUR DRAPER STOCKIST Published by Draper Tools Ltd. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical photocopying, recording or otherwise without prior permission in writing from Draper Tools Ltd.
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS
More information7 FUNCTION DIGITAL MULTIMETER
7 FUNCTION DIGITAL MULTIMETER 90899 OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools. All rights
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationInstruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
More informationModel UT33A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation
More informationSeven function digital multimeter
Seven function digital multimeter 98025 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
More informationModel UT58A/B/C: OPERATING MANUAL
Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationModel UT201/202: OPERATING MANUAL. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness
More informationManual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
More informationUser's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationModel UT33B/C/D: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons Measurement Operation A. DC
More informationEssential Electrical Concepts
Essential Electrical Concepts Introduction Modern vehicles incorporate many electrical and electronic components and systems: Audio Lights Navigation Engine control Transmission control Braking and traction
More informationUT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
More informationHOW TO USE MULTIMETER. COMPILE BY: Dzulautotech
HOW TO USE MULTIMETER COMPILE BY: Dzulautotech 1. GENERAL Electricity is absolutely necessary for an automobile. It is indispensable when the engine is started, the air fuel mixture is ignited and exploded,
More informationTable of Contents. Page 3 4 5 6 8 9 10 11 13 13 14 16 17 19
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Multimeter Structure Functional Buttons Display Symbols Measurement
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More information72-7730 72-7732 Intelligent Digital Multimeters
72-7730 72-7732 Intelligent Digital Multimeters Model 72-7730/72-7732 OPERATING MANUAL TABLE OF CONTENTS CHAPTER TITLE PAGE 1. Before You Start Overview Inspection Safety Information Rules For Safe Operation
More informationModel UT60A: OPERATING MANUAL. Table of Contents. Page 3 4 5 6 8 9 10 11 14 17 17 17 19 19
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols Measurement
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationModel UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents
P/N:110401103671 Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons
More informationTable of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12
Table of Contents The Basics of Electricity 2 Using a Digital Multimeter 4 IDEAL Digital Multimeters An Introduction The Basics of Digital Multimeters is designed to give you a fundamental knowledge of
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationModel UT71A/B OPERATING MANUAL
Model UT71A/B OPERATING MANUAL CHAPTER TITLE PAGE 1. 2. Before You Start Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Getting Acquainted Turning
More informationUser Guide. Model 380260 Insulation Tester / Megohmmeter
User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity
More informationDIGITAL MULTIMETER OPERATION MANUAL ITEM 98674 DIGITAL MULTIMETER CONTENTS
CONTENTS ITEM 98674 OPERATION MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DOS AND DON TS 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 4 2. DESCRIPTION 6 2.1 NAMES OF PARTS 7 2.2 SWITCH, BUTTONS AND
More informationHow To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
More informationElectronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P4.2.1.1
Electronics Operational Amplifier Internal design of an operational amplifier LD Physics Leaflets Discrete assembly of an operational amplifier as a transistor circuit P4.2.1.1 Objects of the experiment
More informationDual Display Digital Multimeter
Dual Display Digital Multimeter GDM-8246 GW INSTEK PART NO. 82DM-82460MG1 This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual
More informationPeak Atlas DCA. Semiconductor Component Analyser Model DCA55. User Guide
GB55-7 Peak Atlas DCA Semiconductor Component Analyser Model DCA55 User Guide Peak Electronic Design Limited 2000/2007 In the interests of development, information in this guide is subject to change without
More informationFundamentals of Signature Analysis
Fundamentals of Signature Analysis An In-depth Overview of Power-off Testing Using Analog Signature Analysis www.huntron.com 1 www.huntron.com 2 Table of Contents SECTION 1. INTRODUCTION... 7 PURPOSE...
More information1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat
Article Text Saturday, March 18, 2000 10:33PM ARTICLE BEGINNING 1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels Volkswagen; EuroVan, Passat DESCRIPTION & OPERATION Instrument cluster for most
More informationABCs of DMMs Multimeter features and functions explained Application Note
ABCs of DMMs Multimeter features and functions explained Application Note Digital multimeters offer a wide selection of features. Choosing the right meter for the job can be challenging unless you know
More informationWhat is a multimeter?
What is a multimeter? A multimeter is a devise used to measure voltage, resistance and current in electronics & electrical equipment It is also used to test continuity between to 2 points to verify if
More informationD-Type Socket Assemblies
D-Type Socket Assemblies Socket Assembly Type No. For Side-on Types E0- E0- E- E- E-00 E-0 E- E-0 E- E-0 E- E- E- E- E- E- E-0 E-0 E- E- E E-00 E-0 E0-0 E0-0 E0-0 E E-0 Applicable MT Diameter mm (/") mm
More informationTalon VFD / Inverter Meter
Talon VFD / Inverter Meter Patent Pending. Copyright 2009. Page 1 of 37 Table of Contents Talon VFD/Inverter meter... 1 Table of Contents... 2 WARNING...3 Product Summary... 4 Product Cautions and Theory
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationCA12 HANDY CAL Temperature Calibrator Model 710 21
Instruction Manual CA12 HANDY CAL Temperature Calibrator Model 710 21 Thank you for purchasing the CA12 HANDY CAL. To fully utilize all of the features of this instrument, read this Instruction Manual
More informationOPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
More informationINTRODUCTION SAFETY PRECAUTIONS/
Title Page No. INTRODUCTION..................................1 SAFTY PRCAUTIONS/WARNINGS.................1 SPCIFICATIONS................................3 CONTROLS AND INDICATORS......................6
More informationUsers Manual. ProcessMeter
787 ProcessMeter Users Manual April 1997, Rev.3, 12/01 1997, 1898, 2000, 2001 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. LIMITED
More informationFig. 1 Analogue Multimeter Fig.2 Digital Multimeter
ELECTRICAL INSTRUMENT AND MEASUREMENT Electrical measuring instruments are devices used to measure electrical quantities such as electric current, voltage, resistance, electrical power and energy. MULTIMETERS
More informationTable of Contents. Title
Table of Contents Title Page No. INTRODUCTION... 2 SAFETY PRECAUTIONS/WARNINGS... 2 SPECIFICATIONS... 3 CONTROLS AND INDICATORS... 8 TESTING PROCEDURES... 10 AUXILIARY FUNCTIONS... 17 BATTERY AND FUSE
More informationHear The Future...Now! SIEM-2T/SIEM-2R
Hear The Future...Now! SIEM-2T/SIEM-2R UHF PLL Mono In Ear Monitoring System 856 59508-03 ATTENTION Please pay high attention to the following information. The guideline published by Occupational Safety
More informationTable of Contents. Page No.
Table of Contents Title Page No. INTRODUCTION... 2 SAFETY PRECAUTIONS/S... 2 SPECIFICATIONS... 3 CONTROLS AND INDICATORS... 8 TESTING PROCEDURES... 10 AUXILIARY FUNCTIONS... 17 BATTERY AND FUSE REPLACEMENT...
More informationwww.elektroexpressz.hu
www.elektroexpressz.hu 2013 1 UT10 SERIES / UT20 SERIES Modern Pocket - Size Digital Multimeters Pocket-Size Digital Multimeters UNI-T UT10A UT10A DC Voltage 400mV/4V/40V/300 ±(0.8%+1) AC Voltage 4V/40V/300V
More informationRADIANT PLASMA 4700 Plasma Spark Generator
RADIANT PLASMA 4700 Plasma Spark Generator Installation Guide / User Manual A S P A R K O F F R E S H A I R Aquapulser.com Contents 1 Introduction 2 1.1 About the Product....................................
More informationLOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
More informationDigital Multimeters 1106 1109 1110 1018/1018H 1030 1009 1011/1012. 1018H Hard case type. 0.3V(16.7kΩ/V) 400mV/4/40/ 3/12/30/120/300/ 400/600V
MULTI METERS Analogue Multimeters Digital Multimeters 1106 1109 1110 1018/1018H 1030 1009 1011/1012 DC V AC V DC A AC A 0.5/5/25/100/ 250/500V (5kΩ/V) 10/50/250/500V (2.5kΩ/V) 200µA/ 2.5/25/250mA 0.1/0.5/2.5/10/
More informationCurrent Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
More informationOPERATING INSTRUCTIONS
Auto TroubleShooter OPERATING INSTRUCTIONS CP7677 Index Safety Precautions... 2 Vehicle Service Information... 3 Visual Inspection... 3 Electrical Specifications... 34 Warranty... 104 1. Multimeter Basic
More informationECEN 1400, Introduction to Analog and Digital Electronics
ECEN 1400, Introduction to Analog and Digital Electronics Lab 4: Power supply 1 INTRODUCTION This lab will span two lab periods. In this lab, you will create the power supply that transforms the AC wall
More informationExperiment 2 Diode Applications: Rectifiers
ECE 3550 - Practicum Fall 2007 Experiment 2 Diode Applications: Rectifiers Objectives 1. To investigate the characteristics of half-wave and full-wave rectifier circuits. 2. To recognize the usefulness
More informationDET Practical Electronics (Intermediate 1)
DET Practical Electronics (Intermediate 1) 731 August 2000 HIGHER STILL DET Practical Electronics (Intermediate 1) Support Materials CONTENTS Section 1 Learning about Resistors Section 2 Learning about
More informationRobot Board Sub-System Testing. Abstract. Introduction and Theory. Equipment. Procedures. EE 101 Spring 2006 Date: Lab Section # Lab #6
EE 101 Spring 2006 Date: Lab Section # Lab #6 Name: Robot Board Sub-System Testing Partner: No Lab partners this time! Abstract The ECEbot robots have a printed circuit board (PCB) containing most of the
More information323/324/325. Calibration Manual. Clamp Meter
323/324/325 Clamp Meter Calibration Manual February 2013 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective
More informationRadio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)
ENGLISH (Original instructions) INSTRUCTION MANUAL Radio BMR00 WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Symbols The following show
More informationThe full wave rectifier consists of two diodes and a resister as shown in Figure
The Full-Wave Rectifier The full wave rectifier consists of two diodes and a resister as shown in Figure The transformer has a centre-tapped secondary winding. This secondary winding has a lead attached
More informationThe table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
More informationUser Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300
User Guide 4 wire Earth Resistance Tester Model GRT300 Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance Tester. The Model GRT300 has been designed and tested according
More information162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL
162 CB CABLE TRACER Filter Probe & Tone Generator INSTRUCTION MANUAL INDEX PAGE 1. INTRODUCTION... 1 2. FILTER PROBE... 1-3 3. TONE GENERATOR... 3-6 4. SPECIFICATION... 7-8 5. MAINTENANCE... 8 1. INTRODUCTION
More informationKit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
More informationNo.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.
No.1 DM368 6½ digits Digital Multimeter Real 6 ½ digits readings resolution Up to 1 K rdgs/s of measurement speed and 512 K rdgs Nonvolatile Memory TrueRMS AC Voltage Current measuring Builtin 1 groups
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationPhysics 3330 Experiment #2 Fall 1999. DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.
Physics 3330 Experiment #2 Fall 1999 DC techniques, dividers, and bridges Purpose You will gain a familiarity with the circuit board and work with a variety of DC techniques, including voltage dividers,
More informationANALOG AND DIGITAL METERS ANALOG VS. DIGITAL METERS VOLTMETERS ANALOG AND DIGITAL
ANALOG VS. DIGITAL METERS Ultimately, your diagnosis of vehicle electrical system problems will come down to using a voltmeter, ammeter, or ohmmeter to pinpoint the exact location of the problem. There
More informationModel 187 & 189. Users Manual. True RMS Multimeter
Model 187 & 189 True RMS Multimeter Users Manual ugust 2000, Rev.2, 6/02 2000, 2002 Fluke Corporation. ll rights reserved. Printed in U.S.. ll product names are trademarks of their respective companies.
More informationBuilding the HVPS High Voltage Power Supply
Introduction Building the HVPS High Voltage Power Supply Voltages higher than the LVPS provides kilovolts are needed in later experiments to get strong electric fields and to generate microwaves. The high-voltage
More informationHow To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationAC Direct Off-Line Power Supplies
AC Direct Off-Line Power Supplies r Introduction Many DC power supplies found in electronic systems, including those in this Tech School, rectify the 120 volts available at an electric outlet. The initial
More informationTechnical Update TAA.TU.11093 Rev. 1
http://www.gambro.com/en/usa_tech/ 800-525-2623 303-222-6500 Technical Update TAA.TU.11093 Rev. 1 Effective: 05 APR 2013 CO# 13084 Product: Subject: From: Phoenix Dialysis System Required Electrical Safety
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationM 140i. Multifunction Calibrator. Operation Manual
M 140i Multifunction Calibrator Operation Manual M-140i Multifunction Calibrator MEATEST, s.r.o. 2 Operation Manual v33 MEATEST, s.r.o. M-140i Multifunction Calibrator Content Operation Manual... 1 Basic
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More informationSeries AMLDL-Z Up to 1000mA LED Driver
FEATURES: Click on Series name for product info on aimtec.com Series Up to ma LED Driver Models Single output Model Input Voltage (V) Step Down DC/DC LED driver Operating Temperature range 4ºC to 85ºC
More informationLoop Calibration and Maintenance
Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains
More information1587/1577. Insulation Multimeters. Users Manual
1587/1577 Insulation Multimeters Users Manual PN 2401027 April 2005 2005 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies. LIMITED WARRANTY
More informationMultimeter measurements on variable frequency drives using the new Fluke 289 DMM
Multimeter measurements on variable frequency drives using the new Fluke 289 DMM Application Note Editor s note: For similar instructions using the Fluke 87V DMM, reference Fluke article 12345. In the
More informationCurrent Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
More informationAVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter
mm AVO410 Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter User manual Bedienungsanleitung Manuel utilisateur Guía del usuario Gebruikershandleiding
More informationFluke 3000 FC Series Test Tools Technical Data
Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect
More informationSPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE 150 650CCA 150 750CCA MARINE 200 700MCA 200 850MCA DEEP CYCLE 17 55Ah 17 80Ah
WARNING Read the operating instructions before use. Lead Acid Batteries can be dangerous. Ensure no sparks or flames are present when working near batteries. Eye protection should be used. Make sure the
More informationLab E1: Introduction to Circuits
E1.1 Lab E1: Introduction to Circuits The purpose of the this lab is to introduce you to some basic instrumentation used in electrical circuits. You will learn to use a DC power supply, a digital multimeter
More informationEVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
More informationMODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
More informationBrio-Rmanual:Cursamanual.qxd 08/04/2011 09:25 Page1
- Brio-Rmanual:Cursamanual.qxd 08/04/2011 09:25 Page1 Brio-Rmanual:Cursamanual.qxd 08/04/2011 09:25 Page2 CONTENTS INTRODUCTION, FEATURES AND TECHNOLOGY 1-3 INSTALLATION 3 CONNECTIVITY 4-6 LOUDSPEAKER
More informationAMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter
AMP-210 AMP-210-EUR 600A AC TRMS Clamp Multimeter AMP-220 AMP-220-EUR 600A AC / DC TRMS Clamp Multimeter AMP-310 AMP-310-EUR 600A AC TRMS Clamp Multimeter AMP-320 AMP-320-EUR 600A AC / DC TRMS Clamp Multimeter
More informationUser Manual for CH-PFC76810
AA Portable Power Corp www.batteryspace.com, Email: Sales@batteryspace.com User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those
More informationThe Basics of Digital Multimeters
IDEAL INDUSTRIES INC. The Basics of Digital Multimeters A guide to help you understand the basic Features and Functions of a Digital Multimeter. Author: Patrick C Elliott Field Sales Engineer IDEAL Industries,
More information200W DISCRETE POWER AMPLIFIER K8060
H8060IP-1 200W DISCRETE POWER AMPLIFIER K8060 Ideal for active speaker system or subwoofer, guitar amp, home theatre systems, instrument amp, etc. Features & Specifications Specifications: Excellent value
More informationDynatek 6080RS multimeter
Dynatek 6080RS multimeter Table of Contents Connection...1 Installing the software...1 Starting the communication...1 Other possibilities...2 File Management...2 Printer...2 Graph screen...3 Programmers
More informationModel 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
More informationTroubleshooting Guide, Freedom and Fleet Power Inverter/Chargers
Technical Note Freedom/Fleet Power 512-0084-01-01 Rev 1 Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Overview This document is a guide for troubleshooting inverters, battery chargers,
More informationModel 77 Series IV Digital Multimeter
Model 77 Series IV Digital Multimeter Introduction XWWarning To avoid electric shock or injury, do not perform the performance tests or calibration adjustment procedures unless qualified to do so. The
More informationInductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
More informationElectrical Fundamentals Module 3: Parallel Circuits
Electrical Fundamentals Module 3: Parallel Circuits PREPARED BY IAT Curriculum Unit August 2008 Institute of Applied Technology, 2008 ATE310- Electrical Fundamentals 2 Module 3 Parallel Circuits Module
More informationBXR 300C BXR 300R. Owner, s Manual P/N 040294
THE SOUND THAT CREATES LEGENDS BXR 300C BXR 300R Owner, s Manual P/N 040294 INTRODUCTION The Fender BXR 300 AMPLIFIER is the most recent effort in state of the art bass amplifier technology, and is a member
More information************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D
************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D INTRODUCTION Power Acoustik amplifiers provide high-performance
More informationTHE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER
THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER Price $1.25 Your MC 2100 stereo amplifier will give you many years of pleasant and satisfactory performance. If you have any questions concerning
More information