B6794. Structured Cabling Infrastructure Specification. Human Services Agency. March 20, 2012

Size: px
Start display at page:

Download "B6794. Structured Cabling Infrastructure Specification. Human Services Agency. March 20, 2012"

Transcription

1 B6794 Structured Cabling Infrastructure Specification Human Services Agency March 20, 2012 Page 1

2 A. GENERAL a. San Joaquin County (referred to as Owner ) is requesting proposals for a new structured cabling infrastructure to be installed at their facility located at 333 Washington Street, Stockton California. B. CONTRACTOR QUALIFICATIONS AND REQUIREMENTS a. Contractor shall design and provide all materials in order to install a complete structure cabling solution that will support voice and data communications. The contractor shall be responsible for providing a communications infrastructure compliant to current county standards; including the procurement of products, installation of cabling infrastructure, fire stopping, verification of performance, and documentation. b. Contractor must possess a valid C-7 California State contractor s license. This license must have been issued 10 years prior to the date of the bid. c. Contactor must have been in telecommunications business for a period of at least 10 years. Contractor must submit at least 3 project references (of similar size and scope to this project). d. The contractor must be certified by the manufactures of the cabling solutions to be installed. To meet the requirements of this specification, the contractor must be a Panduit PCI. In addition, the contractor must have a BICSI RCDD (Registered Communications Distribution Designer) on staff (full time employee). A copy of these certifications must be submitted in the proposal. e. Contractor shall be responsible for all fees and permits required to any governmental agency having jurisdiction over the work in proposal. The contractor shall arrange inspections. f. Contractor shall visit the work site before their proposal will be accepted. No allowances shall be made to the contractor for any extra expense, due to failure or neglect to discover unforeseen conditions affecting the work. g. Contractor employees shall act in a professional manner, and dressed appropriately for the task. No person shall bring alcoholic beverages, controlled substances, firearms, or animals to the job site. Page 2

3 h. Contractor shall clear the work area every evening. If available space exists, contractor equipment and materials may be stored at the facility with approval of the Owner. All packing material shall be disposed of at the end of each day. The Owner will not be responsible for the loss, theft, or damage of any equipment or material. i. Contractor shall follow the security policies and procedures defined by the Owner. This may include providing key access, creating access badges, and escorts for restricted areas. j. The Contractor shall take all precautions necessary to protect existing structures and furniture. Any items that are damaged during the course of the work shall be repaired or replaced by the contractor at no cost to the Owner. k. Owner will provide the contractor with reasonable access to the job site Monday-Friday (Federal / State holidays excluded). Most work must be done after-hours. The Owner will identify the work hours available at the pre-bid meeting. l. Contractor will provide a high-level project plan. This project plan shall identify the tasks, timelines, and a completion date. Any changes to the schedule shall be ed to the Owner weekly. Attached files shall be provided in Microsoft Project or Adobe Acrobat format. m. Contractor shall assign a Project Manager. The Project Manager shall a weekly update status report to the project team members every Friday in Microsoft Project and Adobe Acrobat format. A central off-hours emergency contact number shall be available for evenings and weekends. n. Contractor shall take special precautions to ensure a safe work environment for the employees, contractors, and visitors. o. Contractor will make a reasonable effort to not be disruptive to other contractors, or working staff at the job site. p. Contractor will install only material that is new and undamaged. Refurbished or used materials are not acceptable. Page 3

4 q. Owner expects the workmanship to be of high quality. All equipment shall be plumb and true with the structure. All materials shall be firmly secured in place, adequately supported, and permanent. r. Owner will consider the project complete when all work has been completed, the final documentation has been delivered, and the work site has been cleaned to the Owners satisfaction. s. Contractor agrees to replace or repair, as new, any defective work or materials, which are identified by the Owner within 2 years of final payment. A 25-year manufacture extended warranty shall be provided on the copper cabling solution. t. Performance and technical documentation that should be submitted in your bid include: i. Copy of valid Contractor License (C7) i iv. Three (3) Customer References Copy of valid BICSI RCDD Certificate Copy of valid Panduit PCI Certificate C. CODES, STANDARDS, AND BEST PRACTICES a. All work and materials shall be in full accordance with the latest codes, standards, and best practices. It is the responsibility of the Contractor to have access to each document. In the case that one of the following documents has a ratified update or addendum; it shall be incorporated into this scope of work. If multiple documents provide different requirements, the strictest requirement shall be followed. Not all documents may apply to this project. i. ANSI/TIA/EIA B.1 - Telecommunications Cabling Standard, Part 1: General Requirements (including all the latest ANSI/TIA/EIA B.2 - Telecommunications Cabling Standard, Part 2: Balanced Twisted Pair Cabling Components i ANSI/TIA/EIA B.3 - Telecommunications Cabling Standard, Part 3: Optical Fiber Cabling Components Standard iv. ANSI/TIA/EIA Measurement of Optical Power Page 4

5 Loss of Installed Single-Mode Fiber Cable Plant v. ANSI/TIA/EIA A - Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant vi. ANSI/TIA/EIA TSB-140 Additional Guidelines for Field Testing Length, Loss and Polarity of Optical Fiber Cabling Systems v vi ix. ANSI/TIA/EIA A Pathway and Spaces ANSI/TIA/EIA 606-A Administration Standard for the Telecommunications Infrastructure of Commercial Buildings (labeling identifiers will be provided by Owner) ANSI/TIA/EIA 607-(A) Commercial Building Grounding/Bonding Requirements x. NFPA xi. ANSI/TIA/EIA-942 Telecommunications Infrastructure Standard for Data Centers x ANSI/TIA/EIA-758-(A) Customer-Owned Outside Plant Manual xi BICSI - Telecommunications Distribution Methods Manual (latest edition) xiv. BICSI - Cabling Installation Manual (latest edition) xv. BICSI Customer-Owned Outside Plant Design Manual (latest edition) xvi. FCC 47 CFR 68 xv NEMA 250 xvi NEC - Articles 770 and 800 xix. xx. xxi. xx D. DEFINITIONS ADA - Americans with Disabilities Act ISO/IEC (International) Generic Cabling for Customer Premises Standard (including all the latest amendments and applicable addenda) Title 24 (California Code of Regulation) All Federal, State, and Local Codes a. Construction Documents: Construction drawings, addendums and other documents that are used in conjunction with this specification document. b. Data Connection: A horizontal cabling solution that consists of a UTP cable terminated on a Data Jack at the work area faceplate, and a Data Jack in a modular patch panel within the Telecommunications Room. These connections will be used for Data and VoIP communications. c. Data Jack: The connector used to terminate a single data cable. The Data Jack is a component of a Data Connection. d. Equipment Room (ER): An enclosed space that is used for housing main cross-connects, horizontal cross-connects, and Page 5

6 telecommunications equipment. e. Floor Mount Rack: A floor mounted rack that is used for horizontal cross-connects and telecommunications equipment. f. Work Area Outlet: A faceplate or box/faceplate to protect Jacks in the Work Area. g. Server Room: Another name for the Equipment Room in the construction documents. h. Telecommunications Enclosure (TE): A wall mounted cabinet that is used for horizontal cross-connects, and telecommunications equipment. i. Telecommunications Room (TR): An enclosed space that is used for horizontal cross-connects, and telecommunications equipment. j. Voice Connection: A horizontal cabling solution that consists of a UTP cable terminated on a Voice Jack in the Outlet Box, and a 66- block within the TR or ER. k. Voice Jack: The connector used to terminate a single voice cable. The Voice Jack is a component of a Voice Connection. l. Wall Mount Rack: A wall mounted rack that is used for horizontal cross-connects and telecommunications equipment. m. Work Area: A building space where the occupants interact with Telecommunications equipment. E. Design Criteria a. The goal of this project is the installation of a new communications infrastructure. This installation will provide a communication infrastructure for Data, VoIP, and Traditional Voice. b. Refer to the Construction Plan Documents to identify work area outlet locations. Furniture mounted face plates shall be used in open office spaces (cubicles). Flush mounted faceplates shall be used in offices and all other locations. Surface mount raceway or work area outlets are not allowed without the Owners written permission. c. The Data Connections shall be Category 6, and support Gigabit Ethernet to the desktop. These connections shall support Data and VoIP end points. These connections shall be terminated on modular patch panels. d. The default configuration for each work area location is one (1) Category 6 Data Connection (unless otherwise indicated on the construction documents). Page 6

7 e. The data jacks shall be terminated using the T568B" wiring scheme. f. Blank port covers shall be installed on all unused faceplate and patch panel modular ports. g. Additional Power/Cabling poles shall be installed in the open office areas. Any newly installed poles shall be in vertical/horizontal alignment with the existing poles. New Power/Cabling poles shall match the existing poles. h. All Telecommunication Rooms have existing equipment racks. Additional equipment racks and cabling pathways may be identified before the final addendum. F. EXECUTION a. Work Areas i. The connection at each work area outlet will terminate in the same Telecommunications Room that currently services that outlet. If no outlet currently exists, it will terminate in the closest Telecommunications Room. i iv. Install the specified Data connections identified in the construction drawings. Terminate all Data connections in the closest Telecommunications Room. Work area outlets shall be configured left to right, top to bottom. v. Work area patch cords for each data connection shall be provided. The length of the patch cords shall be 10. b. Telecommunication Rooms i. Data Connections 1. There are 18 Telecommunications Rooms identified in the Construction Documents. 2. Terminate the Data Connections on patch panels in the equipment racks. Page 7

8 3. Provide two Horizontal Wire Managers for each installed patch panel. One is to be installed below the patch panel. The second unit is to be provided to the Owner for self-installation with the network equipment. 4. Patch cords for each data connection shall be provided. a. The length of the patch cords in floor mounted equipment racks shall be 7. b. The length of the patch cord in wall mount equipment racks shall be 5. Firestopping 1. Install firestopping on all new through-wall and through-floor conduits. 2. Install firestopping on all existing telecommunications through-wall and through-floor conduits that currently do not meet code (absence of firestopping material) c. Cable Management i. Velcro cable ties shall be used on UTP cables. Nylon cable ties shall not be used. d. Pathways and Spaces i. Existing cabling pathways may be utilized up to the manufactures recommended fill ratio. For any additional required pathways, the communications contractor shall be responsible for installing J-hooks to provide a pathway from the work area outlets to the server room. The J-hooks shall be independently supported, and not tied to any conduit or ceiling supports. J-hook pathways shall be installed at right angles or parallel to the outside building walls. The distance between J-Hooks shall not exceed the manufactures recommendations. Page 8

9 i The contractor will not exceed NEC s no more than 40% fill specification. A pull sting shall be left in every conduit. iv. A grommet shall be installed on every new conduit that supports communication cable. e. Firestop f. Labeling i. Firestop shall be installed on all installed on all throughwall or through-floor penetrations as required by the NEC. All firestop products shall be installed in accordance with the manufacturer recommendations. Each firestop shall have a minimum 1-hour rating, and shall be identified in the final documentation. i. All cables shall be labeled following the ANSI/ETA/TIA 606-A. This installation shall be treated as a Class IV installation. i All labels shall be printed by a mechanical device (printer, label maker), and shall be legible viewing at 12. On horizontal cabling, printed labels shall be provided within 12 of each end of the cable, on the patch panel, and on the workstation faceplace. g. Testing i. All Data Connections (Category 6) shall be tested to the Category 6 Permanent Link performance specification. The Owner reserves the right to have a representative present during testing. The tester shall be a Fluke DTX 1800 equivalent Level 4 tester. The tester shall be certified by ETL or UL. The tester shall have a valid calibration certificate issued by the manufacture. This certificate shall be provided to the OWNER upon request. i Each data shall be tested after labeling is complete. Page 9

10 G. DOCUMENTATION a. Performance Test Results i. The contractor shall provide tester generated documentation for the Data Connections. i The contractor shall provide a copy of the testers calibration certificate upon request. The test results shall be provided in hard and soft copy formats. The soft copy results shall be provided on CD-R media (LinkWare). b. Site Documentation i. As-built drawings shall be provided in AutoCAD 2004 or newer format. The drawings shall identify the location of the Data, Pathways, and installed Firestop. The diagrams shall be in hard copy and soft copy formats. The printed copy shall be in color. The soft copy file shall be provided on CD-R media (AutoCAD and Adobe Acrobat). H. PRODUCTS a. All products shall be installed in compliance with the manufactures instructions. The Owner has identified products, which are approved for this installation. No substitutions of identified products shall be allowed. This will ensure a quality installation, guarantee performance, and reduce on-going maintenance costs for the life of the solution. b. This is a Graybar VIP Project. Graybar provides enhanced pricing and services for this project. c. This is not a complete parts list. Additional products may be required to complete this installation. d. Horizontal Cabling: The horizontal data cabling solution shall conform to the Category 6 Cabling Specification. Plenum cable is required. Page 10

11 i. UTP Cable 1. The cable to be used for Data Connections is the Landmark1000 by Berk-Tek. The cable jacket shall be plenum rated and White in color. The approved part number is: a. 6P4P24-WH-P-BER-AP Connectivity 1. The workstation jack to be used for data drops is the Panduit Mini-Com TX6 Jack Module, which is Off- White in color. The approved part number is: a. CJ688TGIW i Faceplates 1. The faceplates shall be the Panduit 4-port Executive Faceplate that is White in color. The approved part number is: a. CFPE4WHY iv. Patch Panels 1. The patch panels shall be 48-port modular patch panels by Panduit. The approved part number for the panel is: a. CPP48WBLY v. Horizontal Cable Manager 1. The horizontal cable management solution for the racks is the NetManager series of products from Panduit. The approved part number is: a. NCMH2 vi. UTP Patch Cords 1. The data patch cords shall be Category 6 patch cords by Panduit, which are White in color. The approved part numbers include: a. UTPSP5Y (5 in length) b. UTPSP7Y (7 length) c. UTPSP10Y (10 length) Page 11

12 v J-Hooks 1. For cable supports between the Telecommunications Room and the work area outlets, J-Hooks shall be used. The approved J-Hook Vendor is Erico. The approved part numbers include: a. CAT12 b. CAT21 c. CAT32 d. CAT425 Page 12

Structured Cabling Statement of Work

Structured Cabling Statement of Work Structured Cabling Statement of Work Multiple Locations June 15, 2010 Page 1 A. GENERAL a. San Joaquin County (referred to as Owner ) is requesting proposals for a new structured cabling infrastructure

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.

ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard. WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of

More information

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council Date: 6/19/2013 Version: 1.0 Prepared by: Gregory Cotten Department of General Services District

More information

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Introduction When network managers decide on a cabling system,

More information

DEPARTMENTAL REGULATION

DEPARTMENTAL REGULATION U.S. DEPARTMENT OF AGRICULTURE WASHINGTON, D.C. 20250 DEPARTMENTAL REGULATION SUBJECT: Service Center Technology Modernization Project (SCTMP) Wiring/Cabling Specifications for Service Center Agencies

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

COMMUNICATIONS 270000-1

COMMUNICATIONS 270000-1 SECTION 270000 COMMUNICATIONS PART 1 - GENERAL 1.1 INTRODUCTION/ RELATED DOCUMENTS A. These specifications establish technical and operation requirements for various technologies planned for the CityWalk

More information

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Fiber Optic and Data Cabling Project Shelby Township Police Building

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Fiber Optic and Data Cabling Project Shelby Township Police Building CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL The Charter Township of Shelby is soliciting proposals to install fiber optic and data cabling to serve a new Police Building that is under construction

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

SECTION 28 05 00 COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY

SECTION 28 05 00 COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY SECTION 28 05 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections, apply

More information

The High Cost of a Low-Cost Cable Certification Tester

The High Cost of a Low-Cost Cable Certification Tester The High Cost of a Low-Cost Cable Certification Tester How much does it cost? That is typically the first question a cabling contractor or network owner asks when considering a new certification tester

More information

Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching

Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching 502 Buffalo Rd., Ft. Pierre, SD 57532 (605) 224-1111 or (800) 747-6427 www.windcircle.net sales@windcircle.net Computers

More information

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6 050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY

More information

UT Southwestern Medical Center Information Resources Cable Installation Standard

UT Southwestern Medical Center Information Resources Cable Installation Standard UT Southwestern Medical Center Information Resources Cable Installation Standard PART 1- GENERAL 1.01 SUMMARY A. Furnish and install wire, cable, devices, equipment, and accessories for a complete system

More information

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011 TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS IT Services Infrastructure Services October 2011 Table of Contents 1 Introduction... 4 1.1 Planning and Design... 4 1.2.1 Roles and Responsibilities...

More information

Cable Installation Project

Cable Installation Project Cable Installation Project 1. Intent. It is the intent of the U.S. Court of Appeals to install Category 6 (CAT6) data cabling in the Robert F. Peckham Federal Building and United States Courthouse, 280

More information

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5

Cabling Services (price per pull) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 BryComm, LLC -SDD-1901 Cabling Services (per pull) - Labor Only STANDARD TIME The price per cable pull represents all labor to include fishing walls, running cable through modular furniture, terminating,

More information

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents and Prior Addenda if any, as identified above.

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents and Prior Addenda if any, as identified above. To: All Vendors Bidding on The College of New Jersey Security Cameras Phase III From: Roselle Horodeski Finance and Business Services Date: April 10, 2015 ADDENDUM NO. 1 ISSUE DATE: April 10, 2015 REFERENCE:

More information

REQUEST FOR BID AS-NEEDED CABLING SERVICES FOR COUNTY FACILITIES

REQUEST FOR BID AS-NEEDED CABLING SERVICES FOR COUNTY FACILITIES REQUEST FOR BID AS-NEEDED CABLING SERVICES FOR COUNTY FACILITIES SECTION 1 REQUIREMENTS AND GUIDELINES INTRODUCTION The County of El Paso ( County ) is issuing this Request for Bid ( Solicitation ) to

More information

Specifying an IT Cabling System

Specifying an IT Cabling System Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 10 00 STRUCTURE CABLING TESTING

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 10 00 STRUCTURE CABLING TESTING RELATED SECTIONS: NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT Section 27 00 00 General Requirements Section 27 02 00 General Communication Requirements Section 27 05 26 Grounding and Bonding for Communications

More information

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling

More information

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS Document ID: WP-07-01-ENG Original Issue Date: May 2007 Version: 1.0 FTE Cabling Best Practices 1 Table of Contents Introduction and Applicable Standards...3

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

TCTC Cabling Specifications

TCTC Cabling Specifications TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,

More information

Wired and Wireless Network Request for Proposal New Washington County High School Facility

Wired and Wireless Network Request for Proposal New Washington County High School Facility Washington County Board Of Education P.O. Box 716 501 Industrial Drive Sandersville, GA 31082 (478) 552-3981 FAX (478) 552-3128 Description Wired and Wireless Network Request for Proposal New Washington

More information

ANSI/TIA/EIA-570. 570-A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

ANSI/TIA/EIA-570. 570-A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD BICS I CABLING INSTALLATION PROGRAM ANSI/TIA/EIA-570 Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD Copyright BICSI, October 1999 -A Revisited 1.1 Purpose standardize

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

Telecommunications Systems Narrative Page 1 The Engineering Enterprise

Telecommunications Systems Narrative Page 1 The Engineering Enterprise I. TELECOMMUNICATIONS GENERAL REQUIREMENTS A. The project consists of a renovation to the historic Clinical Sciences building, originally built in 1933. The existing building has a total area of 105,000

More information

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer SYSTIMAX Solutions Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer Issue 2 Draft 1 June 2010 Contents Overview 3 GigaSPEED X10D Guaranteed Channel Performance

More information

Beaver Dam Unified School District Request for Proposal Video Surveillance and Door Access Control Systems

Beaver Dam Unified School District Request for Proposal Video Surveillance and Door Access Control Systems Beaver Dam Unified School District Request for Proposal Video Surveillance and Door Access Control Systems The Beaver Dam Unified School District (BDUSD) is requesting proposals from qualified companies

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

Structured and Point to Point Network Cabling for Industrial Automation

Structured and Point to Point Network Cabling for Industrial Automation Structured and Point to Point Network Cabling for Industrial Automation Introduction Industrial automation systems are undergoing dramatic transformations that require businesses to adopt new strategies

More information

Data Centers and Mission Critical Facilities Operations Procedures

Data Centers and Mission Critical Facilities Operations Procedures Planning & Facilities Data Centers and Mission Critical Facilities Operations Procedures Attachment A (Referenced in UW Information Technology Data Centers and Mission Critical Facilities Operations Policy)

More information

SECTION 16750. TELECOMMUNICATIONS SYSTEM (Cat 6)

SECTION 16750. TELECOMMUNICATIONS SYSTEM (Cat 6) SECTION 16750 TELECOMMUNICATIONS SYSTEM (Cat 6) PART 1 - GENERAL 1.01 REQUIREMENTS A. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements, apply

More information

University of Houston. Telecommunication Cabling Standards

University of Houston. Telecommunication Cabling Standards University of Houston Information Technology Telecommunication Cabling Standards As prepared by IT Network Operations University of Houston, Telecommunication Cabling Standard - Page 1 Table of Contents

More information

LSUHSC Enterprise Networking

LSUHSC Enterprise Networking LSUHSC Computer Services 433 Bolivar Street New Orleans, LA 70112 Phone 504-568-6130 LSUHSC Enterprise Networking Cabling Infrastructure: Design & Installation Standards Addendum 1: Preferred Vendor and

More information

Cabling Services (price per pull)

Cabling Services (price per pull) Cabling Services (per pull) - Labor Only Price Sheet - Standard Hours 14, Cat 5 cable - installed, terminated, tested and labeled including wall plate, jack and certification report. 0-0 Feet $ 77.00 $

More information

UCLA Information Technology Services/ Medical Center Information Technology Services Ronald Reagan UCLA Medical Center

UCLA Information Technology Services/ Medical Center Information Technology Services Ronald Reagan UCLA Medical Center UCLA Information Technology Services/ Medical Center Information Technology Services Ronald Reagan UCLA Medical Center STRUCTURED CABLING Service Level Agreement Effective Date: _07/14/11 Service Level

More information

Data and Voice Network Infrastructure

Data and Voice Network Infrastructure Data and Voice Network Infrastructure Denis Levesque Mike Milne Sponsored By Data and Voice Network Infrastructure Page 1 Copyright APPA 2015 Published by APPA: APPA is the association of choice serving

More information

2301.1 Scope: Communications and Electronic Systems addressed in this section include:

2301.1 Scope: Communications and Electronic Systems addressed in this section include: Chapter 23 COMMUNICATIONS / ELECTRONIC SYSTEMS SECTION 2301 - GENERAL 2301.1 Scope: Communications and Electronic Systems addressed in this section include: 1. Fire Alarm System 2. Telecommunication and

More information

Statement of Work. - 1 - Server Migration & Cable Management. Installation Services. Table of Contents. 1.0 Executive Summary. 2.0 Features & Benefits

Statement of Work. - 1 - Server Migration & Cable Management. Installation Services. Table of Contents. 1.0 Executive Summary. 2.0 Features & Benefits Installation Services Statement of Work - 1 - Server Migration & Server Migration & Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details of Service

More information

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011)

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011) Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011) A. Objectives The Information Technology (IT) Department of Embry-Riddle Aeronautical University (ERAU) seeks to establish a standards-based

More information

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications 3M Telecommunications Solutions for Networks Volition Network Solutions Leading the way in Network Migration through Innovative Connectivity Solutions Innovation The Broadband Migration Path 3M TM Volition

More information

Data Centre & Enterprise Solutions. RapidNet

Data Centre & Enterprise Solutions. RapidNet H E L L E R M A N N T Y T O N Data Centre & Enterprise Solutions RapidNet data centre & Enterprise solutions HellermannTyton is a leading global manufacturer of network cabling solutions which connect,

More information

Generic Category 5e Cabling Specification

Generic Category 5e Cabling Specification Telecommunications Cabling System Technical Specification Category 5e Tyco Electronics Corporation provides this information as a courtesy to its customers and potential customers. Customer should review

More information

SECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

SECTION 17400 ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. SECTION 17400 ACCESS CONTROL SYSTEM CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section. PART 1 - GENERAL 1.1 RELATED WORK A. 16060 Grounding and Bonding B. 16070 Electrical

More information

Standards. www.nordx.com 5 ANSI/TIA/EIA-569-A (CSA T530)

Standards. www.nordx.com 5 ANSI/TIA/EIA-569-A (CSA T530) The primary focus of this standard is to provide design specifications and guidance for all building facilities relating to telecommunications cabling systems and components. This standard identifies and

More information

21 st Century Campus Network Responsibility Matrix 5/26/10

21 st Century Campus Network Responsibility Matrix 5/26/10 Definitions: DoIT Standards This column details the minimal configuration, which DoIT has defined in order to provide a campus-wide standard level of service. Departments may request services, which exceeds

More information

DOUGLAS MIDDLE SCHOOL COMMUNICATIONS CABLING 270000-1

DOUGLAS MIDDLE SCHOOL COMMUNICATIONS CABLING 270000-1 SECTION 270000 (Part of Sub-Bid Section 260001 ELECTRICAL) PART 1 - GENERAL... 3 1.02 SUMMARY... 3 1.03 RELATED SECTIONS... 4 1.04 DEFINITIONS... 5 1.05 REGULATORY REFERENCES... 7 1.06 PERFORMANCE REQUIREMENTS...

More information

DIVISION 27. Telecommunications Systems

DIVISION 27. Telecommunications Systems DIVISION 27 Telecommunications Systems Abstract Division 27 governs the infrastructure for the low-voltage information transport systems (ITS), which include voice, data, and CATV systems and their pathways

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

Division 27 Master Specification for

Division 27 Master Specification for Division 27 Master Specification for Information Transport Systems and Spaces May 1, 2014 1 Table of Contents 1 Section 27 10 01 Structured Cabling General Requirements 1.1 Scope 1.2 Approved Contractor

More information

SECTION 16750 VOICE AND DATA COMMUNICATION CABLING

SECTION 16750 VOICE AND DATA COMMUNICATION CABLING SECTION 16750 VOICE AND DATA COMMUNICATION CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Store drawing set and general provisions of the Contract, including General and Supplementary Conditions and

More information

ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings

ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings ANSI/TIA/EIA-606 Administration Standard for the Telecommunications Infrastructure of Commercial Buildings Distributed by NDS INFORMATION- TELECOM SYSTEM --------------------------------------------- Head

More information

A. The requirements of Section 27 01 00 govern the work specified in this section.

A. The requirements of Section 27 01 00 govern the work specified in this section. SECTION 27 02 00 COMMUNICATIONS CABLING PART 1 GENERAL 1.1 RELATED DOCUMENTS A. The requirements of Section 27 01 00 govern the work specified in this section. B. Refer to the following sections for related

More information

Request for Proposal DESIGN AND INSTALLATION OF STRUCTURED COMMUNICATIONS CABLE SYSTEMS. Kalispell Public Schools

Request for Proposal DESIGN AND INSTALLATION OF STRUCTURED COMMUNICATIONS CABLE SYSTEMS. Kalispell Public Schools Request for Proposal DESIGN AND INSTALLATION OF STRUCTURED COMMUNICATIONS CABLE SYSTEMS For Kalispell Public Schools 2015 TABLE OF CONTENTS I. PROJECT DESCRIPTION / GENERAL SCOPE OF WORK...3 II. PROJECT

More information

ARCHITECTURAL PARTNERS, P.C. 10 Ninth Street, Lynchburg, Va. 24504 434/846-8456 Fax 434/846-4534

ARCHITECTURAL PARTNERS, P.C. 10 Ninth Street, Lynchburg, Va. 24504 434/846-8456 Fax 434/846-4534 DATE: August 25, 2015 TO: All Plan Holders ARCHITECTURAL PARTNERS, P.C. 10 Ninth Street, Lynchburg, Va. 24504 434/846-8456 Fax 434/846-4534 FROM: Jim Vernon, Architectural Partners PROJECT NAME: Nelson

More information

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines This document contains critical information regarding the installation of a certified SYSTIMAX SCS that meets or exceeds performance

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

Intelligent Cable Management Systems

Intelligent Cable Management Systems Intelligent Cable Management Systems Bringing Practical Application Karen Pearson - Leviton Why Cable Management Matters Performance Cooling and air-handling Maintenance ANSI/TIA 569* Telecommunication

More information

SPECIFICATION STANDARD OPTICAL FIBER BACKBONE CABLING 27 13 23

SPECIFICATION STANDARD OPTICAL FIBER BACKBONE CABLING 27 13 23 PART 1: GENERAL 1.01 SCOPE OF WORK SPECIFICATION STANDARD A. Work covered by this Section shall consist of furnishing labor, equipment, supplies, materials, and testing unless otherwise specified, and

More information

Excel Pre-terminated Copper and Fibre Optic Systems

Excel Pre-terminated Copper and Fibre Optic Systems Excel Pre-terminated Copper and Fibre Optic Systems Excel is a world-class premium performing end-to-end infrastructure solution - designed, manufactured, supported and delivered - without compromise.

More information

Category 6 UTP - Cabling System

Category 6 UTP - Cabling System AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP

More information

http://www.icetech.net

http://www.icetech.net Because your network solution depends upon a solid foundation, we can provide comprehensive design, installation, analysis and service of your physical layer. Copper Cabling Installation: Category 3 (Voice)

More information

B. PART 1 - GENERAL of SECTION 271300 BACKBONE COMMUNICATIONS CABLING shall also apply to this section.

B. PART 1 - GENERAL of SECTION 271300 BACKBONE COMMUNICATIONS CABLING shall also apply to this section. SECTION 271500 - HORIZONTAL UTP CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

IT&T Infrastructure Standards

IT&T Infrastructure Standards Technology Services IT&T Infrastructure Standards Version 1.5 17 th April 2015 Page 1 Table of contents 1 CHANGE HISTORY... 3 1.1 DOCUMENT HISTORY... 3 1.2 REVIEWERS... 3 1.3 APPROVALS... 3 2 INTRODUCTION...

More information

Copper Pre-terminated Assemblies

Copper Pre-terminated Assemblies Copper Pre-terminated Assemblies Copper Pre-Terminated Trunk Assemblies Overview Copper Pre-Terminated trunk assemblies are the perfect solution for Enterprise / Premise & Data Centre applications where

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) PART 1 GENERAL 1.1 SECTION

More information

How To Move Your Data Center

How To Move Your Data Center The IT Management Guide to Business Relocation Relocating your business is a major project that entails careful planning. You want to minimize the disruption to your business, provide a new space that

More information

Information and Communication Technology Network Cabling Infrastructure Standard

Information and Communication Technology Network Cabling Infrastructure Standard Approved on Dec-2005 by Eugene Formato Manager, Communications Services Last Amended Aug-2009 by Jarren Beveridge Network Engineer, Communications Services Scheduled for Review Jan-2010 Information and

More information

A. Provide roughing-in, including the empty boxes, conduit, pull strings, etc. under Division 26 for the following related Sections:

A. Provide roughing-in, including the empty boxes, conduit, pull strings, etc. under Division 26 for the following related Sections: SECTION 270500 COMMON WORK RESULTS FOR COMMUNICATIONS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Voice over IP System

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Voice over IP System CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL Voice over IP System The Charter Township of Shelby is soliciting proposals to install a complete Voice over IP telephone system, including call control

More information

CONTRACT DATA SHEET TELEPHONE/DATA INSTALLATION & REPAIR CONTRACT #: 1015-14 CONTRACT DATES: 12/16/14-11/30/15

CONTRACT DATA SHEET TELEPHONE/DATA INSTALLATION & REPAIR CONTRACT #: 1015-14 CONTRACT DATES: 12/16/14-11/30/15 CONTRACT DATA SHEET Monroe County Division of Purchasing 200 County Office Building, Rochester NY 14614 TITLE: TELEPHONE/DATA INSTALLATION & REPAIR CONTRACT #: 1015-14 CONTRACT DATES: 12/16/14-11/30/15

More information

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope Design Guide Universal Connectivity Grid SYSTIMAX Solutions from CommScope CONTENTS Introduction 3 Commercial building network overview 4 Zone cabling 5 Universal Connectivity Grid 6 UCG cell size 7 Integrating

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection.

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection. DIVISION 16 ELECTRICAL Section 16740 Telephone System PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

The Pennsylvania State University ------------- Physical Security Office. Intrusion Alarm. Performance Specification

The Pennsylvania State University ------------- Physical Security Office. Intrusion Alarm. Performance Specification The Pennsylvania State University ------------- Physical Security Office Intrusion Alarm Performance Specification By PHYSICAL SECURITY OFFICE Group (Access Controls & Electronic Security Programs) and

More information

SECTION 16715 TELECOMMUNICATIONS ACCEPTANCE TESTING

SECTION 16715 TELECOMMUNICATIONS ACCEPTANCE TESTING PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Inspection and testing procedures for copper and fiber optic cable, RF CATV / MATV systems, and the antenna systems. C. Documentation

More information

Building Design Guidelines

Building Design Guidelines Building Design Guidelines Campus Technology Infrastructure Version: February 2010 Contents INTRODUCTION... 4 Documentation Requirements References and Documents for Telecommunications Standards and Guidelines

More information

SECTION 27 20 00 - DATA COMMUNICATIONS. A. Complete vertical and horizontal Communication/Data Network System as indicated.

SECTION 27 20 00 - DATA COMMUNICATIONS. A. Complete vertical and horizontal Communication/Data Network System as indicated. SECTION 27 20 00 - PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this

More information

Gigabit Passive Optical Networks

Gigabit Passive Optical Networks White Paper Gigabit Passive Optical Networks Passive Optical LAN Solutions (POLS) Theory, Design, and Installation Considerations Sean McCloud, RCDD Senior Applications Engineer, Leviton Network Solutions

More information

University of Nevada, Reno Campus Design & Construction Standards

University of Nevada, Reno Campus Design & Construction Standards DIVISION 27: COMMUNICATION 27000 - General Network Standards and Policies The intent of the network policies are: To ensure that computer networking is treated as an essential component of all new and

More information

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING

SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete

More information

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions TABLE OF CONTENTS TABLE OF CONTENTS... 2 INTRODUCTION... 3 CABLING

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1

More information

SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES

SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,

More information

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8 Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,

More information

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD Data Center Standards Roundup BICSI, TIA, CENELEC, ISO Steve Kepekci, RCDD Introduction Regardless of business activity or size, all information technology (IT) groups have similar needs Provide secure,

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

TECHNOLOGY GUIDELINES

TECHNOLOGY GUIDELINES TECHNOLOGY GUIDELINES BUILDING INFRASTRUCTURE BEST PRACTICES FOR STATE-OWNED BUILDINGS THE OFFICE OF MN.IT SERVICES 1 April 06, 2015 TABLE OF CONTENTS Page Number Overview 2 Basic Requirements 3 1.1 Regulatory

More information

Harvard University Information Technology Standards Construction Specifications Institute Master Format Division 270000

Harvard University Information Technology Standards Construction Specifications Institute Master Format Division 270000 Harvard University Information Technology Standards Construction Specifications Institute Master Format Division 270000 10/1/2014 DIVISION 270000 COMMUNICATIONS TABLE OF CONTENTS SECTION 27 00 00 COMMUNICATIONS

More information

Chassell Township Schools USF RFPs can be found at www.chassellschools.org/usf15

Chassell Township Schools USF RFPs can be found at www.chassellschools.org/usf15 Chassell Township Schools USF RFPs can be found at www.chassellschools.org/usf15 RFP closing date March 17, 2015 Chassell Township Schools C/O Copper Country Intermediate School District Jason G. Auel

More information

Request for Quote E-Rate Eligible Services Scope of Work - Internal Connections: Network Infrastructure Equipment and Cabling

Request for Quote E-Rate Eligible Services Scope of Work - Internal Connections: Network Infrastructure Equipment and Cabling Request for Quote E-Rate Eligible Services Scope of Work - Internal Connections: Network Infrastructure Equipment and Cabling Due Date: Allowable Contract Date from Posted 470 The Saddle Mountain Unified

More information

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov. Slide Number 1

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov. Slide Number 1 Nathan Dayton SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov Slide Number 1 NETWORK DESIGN Slide Number 2 Previously there have been two phases in the design of a network Department Design Interconnect Design

More information

Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.

Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards. Cat 5, 6 or 7? A University Standard for Structured Wiring. Background isolutions recently formed Incorporates all IT service providers within the University. Focus on all ICT needs of the user and the

More information

Request for Proposal

Request for Proposal Shelby County Tennessee Mark H. Luttrell, Jr., Mayor Request for Proposal Shelby County Government Purchasing Department 160 N. Main, Suite 550 Memphis, TN 38103 Issued: March 18, 2011 Due: April 8, 2011

More information