TURNING AIR INTO SOLUTIONS. PROPELLER WALL FANS (DIRECT & BELT DRIVEN) WPD WPB

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "TURNING AIR INTO SOLUTIONS. PROPELLER WALL FANS (DIRECT & BELT DRIVEN) WPD WPB"

Transcription

1 TURNING AIR INTO SOLUTIONS. PROPLLR WALL S (DIRCT & BLT DRIVN) WPD WPB CATALOG 48 September

2 PROPLLR WALL S Overview WPB WPD Twin City Fan & Blower WPD Medium Duty and WPB Light and Medium Duty Propeller Wall Fans are specifically designed for cost effective, general-purpose ventilation. All models are available in either exhaust or supply configurations. The steel panel design is available with cast aluminum or fabricated steel propellers to meet specific application requirements. Regardless of the application, the WPD and WPB Series offers a high quality, cost competitive propeller fan solution. Model WPD with "" Series Propeller Construction Features aluminum or fabricated steel propellers. panel with deep formed inlet venturi which distributes air velocity uniformly. Pre-punched mounting holes for ease of installation. Motor supports are constructed of heavy-gauge galvanized steel. Fans designed for exhaust and supply service are provided with motor and drive located on the interior side of the building. Pre-engineered accessories to accommodate any installation. Dynamically balanced propellers for quiet, vibration-free operation. Designed for continuous duty. iron pillow block bearings selected for L0 average life of 0,000 hours at maximum cataloged operating speeds. Sizes 4" to 60" wheel diameters Model WPB with "L" Series Propeller Performance Airflow to 6,800 CFM Static pressure to " w.g. Models WPD and WPB are UL/cUL 70 listed for electrical, File No FS For complete product performance, drawings, and available accessories, Download Fan Selector at tcf.com. Twin City Fan & Blower, a Twin City Fan Company certifies that the WPD and WPB Wall Propeller Fans shown herein are licensed to bear the AMCA Seal. The Ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication and comply with the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air and sound performance for Model WPD Sizes 44, 48, 4B, 64, 68, 6B, 84, 88 and 8B on page and Model WPB Sizes L, L, 4, 8, B and 4L on pages 4-. The AMCA Certified Ratings Seal applies to the Fan fficiency Grade for Model WPD Sizes B, 4, 8, 4B, 44, 48, 4Z, 0B, 04, 08, 0Z, 6B6, 64, 68, 6Z, 4B04, 44, 48, 4Z, 48B04, 484, 488 and 48Z on pages - and Model WPB Sizes 4L, 4B, 44, 48, 4Z, 0L, 0L, 0B, 04, 08, 0Z, 6L, 6L, 6B04, 64, 68, 6Z, 4L, 4L, 4B04, 44, 48, 4Z, 48L, 48L, 48B04, 484, 488, 48Z, 4L, 4L, 4B406, 4C, 4C6, 4Z, 60L, 60L, 60C, 60C6 and 60Z on pages -. TWIN CITY - CATALOG 48

3 PROPLLR WALL S Propellers WPB WPD WPD and WPB propeller fans are available with either fixed pitch fabricated steel (sizes through 60) or adjustable pitch cast aluminum propellers (sizes 4 through 60). ach propeller type is designed for a wide variety of commercial market applications with static pressure capabilities from 0" to ". Regardless of the application requirement, WPD and WPB propellers offer the right choice. SIZ DIRCT DRIV BLT DRIVN 4 B, 6 B, 8 B, B, L, L, B, 4 B,, Z L, L, B,, Z 0 B,, Z L, L, B,, Z 6 B,, Z L, L, B,, Z 4 B,, Z L, L, B,, Z 48 B,, Z L, L, B,, Z 4 L, L, B, C, Z 60 L, L, C, Z Propeller Availability L & L Propellers The L and L series features fixed pitch, fabricated steel, -bladed propellers. Galvanized steel propeller blades are riveted to galvanized steel hubs. Available in 8 sizes from to 60 diameters in either standard L construction or reinforced L construction. B Die Propellers The B series features a die cast aluminum propeller available in 4, and 6 blade designs. Blade angles are factory set and mounted in a die cast aluminum hub. B propellers are available in 4" through 4" diameters. Die Propellers The series features a die cast aluminum propeller available in 4 and 8 blade designs. Blade angles are factory set and mounted in a die cast aluminum hub. propellers are available in 4" through 48" diameters. C Propellers The C series is a cast aluminum propeller available in 4 and 6 blade designs, and is available in 4" and 60" diameters only. Blade angles are factory set and mounted in a cast aluminum hub. Z Propeller The Z series features a fixed pitch, fabricated steel, -bladed propeller. blades are continuously welded to a heavy gauge hub at the customer s selected blade angle. Z propellers are available in 4" through 60" diameters.

4 PROPLLR WALL S WPD/WPB Model Nomenclature WPB B Model WPD = Wall Propeller Fan, Direct Drive WPB = Wall Propeller Fan, Belt Driven = xhaust, S = Supply Fan Size Propeller Type L & L = Level & Level,, Fixed Pitch (-Bladed) B =, Adjustable Pitch (4,, and 6-Bladed) =, Adjustable Pitch (4 and 8-Bladed) C =, Adjustable Pitch (4 and 6-Bladed) Z =, Fixed Pitch (-Bladed) Hub Designation (B Propellers Only) No. of Blades Propeller Blade Angle (B, C,, and Z Propellers Only) TCF Model Comparison Twin City Fan offers a full line of propeller fans available in both direct drive and belt driven. ach model and propeller type has been designed for a wide variety of commercial market applications. No matter what the requirements are, Twin City Fan has the propeller fan to suit the application. LVL 4 LVL PROPLLR CONSTRUCTION Blades Riveted to Hubs Blades and Hubs MODL SIZ RANG PRFORMANC RANG CFM STATIC PRSSUR CAPABILITY PRFORMANC DATA LOCATION TCP 8-4 to 7, Up to 0.6 in w.g. Catalog to,0 WPD Blades and Hubs 4-48,0 to,0 Blades and Hubs PROPLLR CONSTRUCTION Galvanized Blades Riveted to Galvanized Hubs Reinforced Galvanized Blades Riveted to Galvanized Hubs Blades and Hubs Direct Drive TCWP to 9,980 TCWPX 4-60,640 to 7,000 MODL SIZ RANG Belt Driven PRFORMANC RANG CFM Up to.00 in w.g. Pages - Up to.0 in w.g. STATIC PRSSUR CAPABILITY Catalogs AX00 & AX PRFORMANC DATA LOCATION WPB L -60,970 to,0 Up to 0.7 in w.g. Pages 4- WPB L -60,40 to 47,600 Up to 0.7 in w.g. Pages ,0 to 6,700 Pages 4- WPB L Up to.00 in w.g. Blades and Hubs 4-60,00 to 6,800 Pages - 4 Blades and Hubs TCWP 4-48,600 to 8,000 TCWPX 4-7 4,000 to 7,000 Up to.0 in w.g. Catalogs AX00 & AX 4 TWIN CITY - CATALOG 48

5 PROPLLR WALL S Pressure Drops Supply & xhaust supports by others XHAUST in Wall Box with Backdraft Damper & Weatherhood supports by others SUPPLY in Wall Box with Backdraft Damper & Weatherhood SIZ CFM PRSS. DROP (IN. W.G.) XHAUST SUPPLY SIZ CFM PRSS. DROP (IN. W.G.) XHAUST SUPPLY SIZ 4 PRSS. DROP CFM (IN. W.G.) XHAUST SUPPLY

6 OPTIONS/ACCSSORIS Airflow Removable Screen Standard component of wall box and motor side guard. Screen is available with bolted removable or hinged construction. Allows for access to motor, bearings and drive components. Wall Box is used to mount the fan and accessories cleanly into a wall, and provides the strongest and safest way to mount wall fans. Wall boxes are constructed of 6-gauge galvanized steel and are provided with heavy-gauge mounting flanges with prepunched mounting holes for ease of installation. Available fully assembled or as a kit (field assembly required) to reduce shipping costs. Wall supports are provided by others. xtended Lube Lines with grease fittings are extended to the outside of the fan housing. Birdscreen protects the fan's internal components from entry of birds. 6 Filter Box For applications requiring filtered air, filter boxes are available with wall box or wall collar and fan in supply configuration. Filter box contains " thick aluminum washable filters and access panels as standard. Disposable filters and " options are also available upon request. Contact factory for more information. Weatherhood keeps snow and rain from entering the building and to prevent wind from altering the performance of the fan and backdraft damper. The weatherhood is designed to fit over the backdraft damper and can be installed to a wall collar via the mounting flanges and prepunched mounting holes. Weatherhoods are constructed of G90 galvanized steel and are standard with a removable galvanized steel, wire mesh, bird screen. Available fully assembled or as a kit (field assembly required) to reduce shipping costs. Weatherhoods are not weather tight when used with supply fans. 6 TWIN CITY - CATALOG 48

7 OPTIONS/ACCSSORIS Airflow OSHA Motor Side Guard with Removable Screen meets OSHA standards by completely enclosing the motor and drive components. Motor side guards are constructed of galvanized steel side sheets and a removable wire mesh screen. Prepunched mounting holes allow for easy installation to the fan. Can be used with or without a wall collar. NMA4 Disconnect Switch NMA-4 Disconnect provides positive electrical shutoff when fan cleaning or maintenance of fan and is water and dust tight. Switch is available shipped loose for field mounting and wiring or factory mounted and wired. See page 8 for other available disconnect switches. Single Point Wiring Available with factory assembled motor side guard or wall box, wired disconnect switch and motorized backdraft damper. Single point wiring option provides a single location for making connections to the damper actuator and disconnect switch. Wall Collars are an economical alternative to the wall box. Wall collars are constructed of 6-gauge galvanized steel. Heavy-gauge mounting flanges with prepunched mounting holes are provided for ease of installation. Available fully assembled or as a kit (field assembly required) to reduce shipping costs. If motor side of fan is to be enclosed, add OSHA motor side guard. Wall supports by others. 6 Backdraft Dampers are used to keep the elements and unwanted air out of the building when the fan is not in use. They are constructed to easily fasten to the wall box or wall collar so that the weatherhood or damper guard can easily fit over it. The standard damper frame is constructed of.06 extruded aluminum and the blades are constructed of 6-gauge mill finished aluminum. The leading edge of each damper blade is flanged with a vinyl seal for effective weather protection and quiet closing. Heavy duty/high velocity dampers are provided when the fan is selected at higher air volumes (see velocity table on page ). Frame and blades are.080 extruded aluminum. The blades freely pivot open or close on stainless steel pivot pins on both types. Motorized options are available. See page for additional information on backdraft damper limits. Damper Guard protects the backdraft damper when a weatherhood is not used. It is constructed of 8-gauge G90 galvanized steel side sheets and a galvanized steel screen. The screening complies with OSHA standards and will keep birds out of the fan and building. Mounting flanges and prepunched mounting holes are provided for ease of installation. 7

8 DISCONNCT SWITCHS Overview Disconnect switches provide positive electrical shutoff during fan cleaning or maintenance. NMA- Disconnect Switch (Standard) A NMA- disconnect switch is available shipped loose for field mounting and wiring or factory mounted and wired with ODP or TFC motors. NMA- Disconnect Switch NMA-R Disconnect Switch A NMA-R, rain proof, disconnect is available shipped loose for field mounting and wiring or factory mounted and wired externally. NMA-4 Disconnect Switch A NMA-4, water and dust tight, disconnect is available shipped loose for field mounting and wiring or factory mounted and wired externally. NMA-R Disconnect Switch NMA-7/9 Disconnect Switch A NMA-7/9 disconnect switch is recommended on fans with explosion proof motors. The NMA-7/9 switch is designed for use with fans operating in hazardous environments. Available shipped loose for field mounting and wiring. (Not shown.) NMA-4 Disconnect Switch 8 TWIN CITY - CATALOG 48

9 MOUNTING ARRANGMNTS MOUNTING FLANG MOUNTING FLANG Flush with Outside Wall RMOVABL GUARD SCRN AIR FLOW SUPPORTS (BY OTHRS) BACKDRAFT DAMPR xhaust WATHRHOOD WITH SCRN RMOVABL GUARD SCRN AIR FLOW SUPPORTS (BY OTHRS) BACKDRAFT DAMPR Supply WATHRHOOD WITH SCRN MOUNTING FLANG MOUNTING FLANG BACKDRAFT DAMPR BACKDRAFT DAMPR Middle of Wall RMOVABL GUARD SCRN AIR FLOW xhaust WATHRHOOD WITH SCRN RMOVABL GUARD SCRN AIR FLOW Supply WATHRHOOD WITH SCRN SUPPORTS (BY OTHRS) SUPPORTS (BY OTHRS) MOUNTING FLANG MOUNTING FLANG Flush with Interior Wall RMOVABL GUARD SCRN AIR FLOW SUPPORTS (BY OTHRS) BACKDRAFT DAMPR xhaust WATHRHOOD WITH SCRN RMOVABL GUARD SCRN AIR FLOW SUPPORTS (BY OTHRS) BACKDRAFT DAMPR Supply WATHRHOOD WITH SCRN Mounting without Accessories AIR FLOW SPACR (BY OTHRS) MIN BACKDRAFT DAMPR SIZ MIN TO ACHIV TH MINIMUM DIMNSION, THIS INSTALLATION RQUIRS A SPACR (BY OTHRS) BTWN TH AND TH WALL. IF TH WALL IS QUAL TO OR GRATR THAN TH MINIMUM DIMNSION, TH CAN B MOUNTD DIRCTLY TO TH WALL. Dimensions are in inches. 9

10 NGINRING DATA Approx. Shipping Weight (LB.) WPD WPB SIZ B 4 8 Z L L B 4 8 C C6 Z Material Specification SIZ GAUG OF MATRIAL SHAFT SIZ (IN.) PANL DRIV FRAM PROPLLRS HUBS WPB WPB WPB WPD L/L B//C/Z WPD L/L B//C/Z L/L B C Z L/L Z L L B//C/Z DI DI 4 /4 / CAST 4 4 /4 /4 CAST ALUM. 4 4 /4 ALUM / /6 / /6 7 / CAST 7 /6 7 / ALUM. /6 7 /6 / /6 Outlet Velocities SIZ STANDARD HAVY DUTY DAMPR DAMPR OUTLT VLOCITY MAX. FPM MIN. FPM Backdraft Damper Limits STANDARD DAMPR HAVY DUTY DAMPR SIZ VLOCITY MAX. VLOCITY MAX. CFM MAX. CFM MAX. (FPM) (FPM) Not Required TWIN CITY - CATALOG 48

11 PRFORMANC DATA DIRCT DRIV WPD Sizes 4- MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. SIZ PROPLLR BLAD HP RPM 0" SP ANGL GRAD Max RPM B = 70 4 = 70 8 = 70 Max Motor Frame Size = 6 Outlet Area (ft ) = B / / B 4 8 B 4 8 B / / / / Max RPM B = 70 4 = 70 8 = 70 Max Motor Frame Size = 6 Outlet Area (ft ) = / / / / / / / / Max RPM B = 70 4 = 70 8 = 70 Max Motor Frame Size = 6 Outlet Area (ft ) =.8 / / / / / / / / Max RPM B = 70 4 = 70 8 = 70 Max Motor Frame Size = 4T Outlet Area (ft ) =.46 / / FG / / / / / FG67 4 / NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Performance ratings do not include the effects of appurtenances (accessories).. The sound ratings shown are loudness values in fan sone at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 4. The AMCA Certified Ratings Seal applies to sone ratings only.

12 PRFORMANC DATA DIRCT DRIV WPD Sizes 4-6 MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. SIZ PROPLLR BLAD HP RPM 0" SP ANGL GRAD Max RPM B = 70 4 = 70 8 = 70 Z = 70 Max Motor Frame Size = 84T Outlet Area (ft ) =. / B / FG / Z B 4 8 Z B6 4 8 Z 6 / / / / / / / / / Max RPM B = 60 4 = 60 8 = 60 Z = 60 Max Motor Frame Size = 84T Outlet Area (ft ) =.0 / / / / / / / / / Max RPM B6 = 60 4 = 60 8 = 60 Z = 60 Max Motor Frame Size = T Outlet Area (ft ) = / / / FG7 FG67 FG67 FG7 FG67 FG7 NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Performance ratings do not include the effects of appurtenances (accessories).. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 4. The AMCA Certified Ratings Seal applies to sone ratings only. TWIN CITY - CATALOG 48

13 PRFORMANC DATA DIRCT DRIV WPD Sizes 4-48 MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. SIZ PROPLLR BLAD HP RPM 0" SP ANGL GRAD Max RPM B04 = = = 860 Z = 860 Max Motor Frame Size = 4T Outlet Area (ft ) = B04 / / FG FG Z Max RPM B04 = = = 860 Z = 860 Max Motor Frame Size = 4T Outlet Area (ft ) =.76 / B FG FG67 Z FG7 NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Performance ratings do not include the effects of appurtenances (accessories).. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels. 4. The AMCA Certified Ratings Seal applies to sone ratings only.

14 PRFORMANC DATA BLT DRIVN WPB Size MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS PROPLLR BLAD HP RPM 0" SP ANGL Level Performance Max RPM L = 8 Max Motor Frame Size = 6 Outlet Area (ft ) = / L / / Level Performance Max RPM L = 4 Max Motor Frame Size = 4T Outlet Area (ft ) = L / / Level Performance Max RPM B = = = 80 Max Motor Frame Size = 4T Outlet Area (ft ) = / B / / / / / / / / / / / FF. GRAD NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only. 4 TWIN CITY - CATALOG 48

15 PRFORMANC DATA BLT DRIVN WPB Size 4 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 907 Max Motor Frame Size = 6 Outlet Area (ft ) = / / L / / Level Performance Max RPM L = 986 Max Motor Frame Size = 4T Outlet Area (ft ) = / L / Level Performance Max RPM B = 90 4 = 90 8 = 7 Z = 40 Max Motor Frame Size = 4T Outlet Area (ft ) = / B 4 8 Z / / / / / / / / / / / FF. GRAD FG67 FG6 FG67 NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only.

16 PRFORMANC DATA BLT DRIVN WPB Size 0 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 696 Max Motor Frame Size = 4T Outlet Area (ft ) = / / L / / Level Performance Max RPM L = 90 Max Motor Frame Size = 84T Outlet Area (ft ) = / L / FF. GRAD FG67 FG67 NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only. 6 TWIN CITY - CATALOG 48

17 PRFORMANC DATA BLT DRIVN WPB Size 0 (continued) MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. PROPLLR BLAD HP RPM 0" SP ANGL GRAD Level Performance Max RPM B = 6 4 = 6 8 = 97 Z = 9 Max Motor Frame Size = 84T Outlet Area (ft ) = / / B / / / FG / / / FG67 / / Z / / NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only. 7

18 PRFORMANC DATA BLT DRIVN WPB Size 6 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = Max Motor Frame Size = 4T Outlet Area (ft ) = / / L L / Level Performance Max RPM L = 69 Max Motor Frame Size = 84T Outlet Area (ft ) = / Level Performance Max RPM B6 = 9 4 = 9 8 = 9 Z = 9 Max Motor Frame Size = 84T Outlet Area (ft ) = B6 4 8 Z / / / / / / / / NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). FF. GRAD FG6 FG6 FG67 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only. 8 TWIN CITY - CATALOG 48

19 WPB Size 4 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 44 Max Motor Frame Size = 4T Outlet Area (ft ) = / / L / Level Performance Max RPM L = 7 Max Motor Frame Size = 84T Outlet Area (ft ) = / L Level Performance Max RPM B04 = 96 4 = 96 8 = 660 Z = 870 Max Motor Frame Size = T Outlet Area (ft ) = B Z / / / / PRFORMANC DATA BLT DRIVN FF. GRAD FG6 FG6 FG67 FG67 FG7 NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only. 9

20 PRFORMANC DATA BLT DRIVN WPB Size 48 MODL INFO CFM / STATIC PRSSUR (IN. W.G.) MOTOR MAX SONS FF. PROPLLR BLAD HP RPM 0" SP ANGL GRAD Level Performance Max RPM L = Max Motor Frame Size = 4T Outlet Area (ft ) = / L / FG Level Performance Max RPM L = 608 Max Motor Frame Size = 84T Outlet Area (ft ) = / L FG Level Performance Max RPM B04 = 4 = 8 = 670 Z = 80 Max Motor Frame Size = T Outlet Area (ft ) = / B Z / / / / / / FG7 FG67 NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only. TWIN CITY - CATALOG 48

21 WPB Size 4 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 4 Max Motor Frame Size = 4T Outlet Area (ft ) = / L / Level Performance Max RPM L = 08 Max Motor Frame Size = 84T Outlet Area (ft ) = / L PRFORMANC DATA BLT DRIVN Level Performance Max RPM B406 = 98 C = 98 C6 = 79 Z = 66 Max Motor Frame Size = 4T Outlet Area (ft ) = / B FG / / C FG / / C FG / / Z / FF. GRAD FG6 FG6 NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only.

22 PRFORMANC DATA BLT DRIVN WPB Size 60 MODL INFO MOTOR MAX SONS CFM / STATIC PRSSUR (IN. W.G.) PROPLLR BLAD ANGL HP RPM 0" SP Level Performance Max RPM L = 00 Max Motor Frame Size = 4T Outlet Area (ft ) = / L L / Level Performance Max RPM L = 99 Max Motor Frame Size = T Outlet Area (ft ) = / Level Performance Max RPM C = 9 C6 = 80 Z = 68 Max Motor Frame Size = 6T Outlet Area (ft ) = C / C / / Z / FF. GRAD FG6 FG6 FG6 FG6 NOTS:. Performance certified is for installation type A: Free inlet, free outlet.. Power rating (BHP) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound ratings shown are loudness values in fan sones at ft. (.m) in a hemispherical free field calculated per AMCA Standard 0. Values are for installation Type A: Free inlet hemispherical sone levels.. The AMCA Certified Ratings Seal applies to sone ratings only. TWIN CITY - CATALOG 48

TURNING AIR INTO SOLUTIONS. SQUARE INLINE CENTRIFUGAL FANS DSI BSI

TURNING AIR INTO SOLUTIONS. SQUARE INLINE CENTRIFUGAL FANS DSI BSI TURNING AIR INTO SOLUTIONS. SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 March 06 SQUARE INLINE CENTRIFUGAL FANS Models DSI BSI Twin City Fan s DSI direct drive and type BSI belt driven square inline

More information

fixed pitch propeller fans

fixed pitch propeller fans Air Moving Solutions. fixed pitch propeller fans MODEL TCWP CATALOG AX500 December 2012 PropellerFans Model TCWP Fixed Pitch Heavy-Duty Construction Twin City Fan & Blower fixed pitch propeller fans, model

More information

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD

More information

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

UPBLAST & HOODED PROPELLER ROOF VENTILATORS The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust

More information

SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer. PART 1 GENERAL SECTION 23 34 13 HVAC FANS 1.01 SUMMARY A. Section Includes: 1. Exhaust fans. 2. Transfer fans. B. Related Documents: 1. Drawings and general provisions of the Contract, including General

More information

PANEL AND RING FANS. Macheta Airfoil Design Propellers Direct Drive & Belt Driven Sizes 9" thru 96" Direct Drive Ring Fan. Direct Drive Panel Fan

PANEL AND RING FANS. Macheta Airfoil Design Propellers Direct Drive & Belt Driven Sizes 9 thru 96 Direct Drive Ring Fan. Direct Drive Panel Fan The Industrial Choice. Direct Drive Ring Fan Direct Drive Panel Fan PANEL AND RING S Macheta Airfoil Design Propellers Direct Drive & Belt Driven Sizes 9" thru 96" BULLETIN 168-B January 1999 Aerovent

More information

Ventilation Solutions Kitchens. fantech

Ventilation Solutions Kitchens. fantech Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the

More information

Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller

Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller Belt Drive Low and High Pressure October 009 Features Page Header Tube Axial Roof Upblast Fans Greenheck belt drive tube axial upblast

More information

SERIES I HIGH PRESSURE BLOWERS. 7697 Snider Road, Mason, OH 45040-9135 Telephone: 513-573-0600. Cat. No. HP-I-107

SERIES I HIGH PRESSURE BLOWERS. 7697 Snider Road, Mason, OH 45040-9135 Telephone: 513-573-0600. Cat. No. HP-I-107 OEM and Industrial Air Handling Specialist HP SERIES I HIGH PRESSURE BLOWERS 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more information. Cat. No.

More information

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional

More information

AIR CONDITIONING PRODUCTS COMPANY

AIR CONDITIONING PRODUCTS COMPANY Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter

More information

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to

More information

FAN & BLOWER CENTRIFUGAL FANS

FAN & BLOWER CENTRIFUGAL FANS FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

CE8000 Energy Recovery Ventilator

CE8000 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 7000-8500 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel 18-gauge

More information

ROOF TOP MOUNTED Air Handler Specification

ROOF TOP MOUNTED Air Handler Specification ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor

More information

security products metric sizes Redefine your comfort zone. www.titus-hvac.com

security products metric sizes Redefine your comfort zone. www.titus-hvac.com metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS OCTOBER 18, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS OCTOBER 18, 2013 SECTION 233416 - CENTRIFUGAL HVAC FANS PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Fans shall be dynamically balanced and factory-tested and certified in accordance with applicable AMCA test codes. All

More information

Miami-Dade Qualified Drainable Blade Louvered Penthouse

Miami-Dade Qualified Drainable Blade Louvered Penthouse Application and Design is a gravity intake or exhaust louvered penthouse. Model incorporates high performance horizontal drainable style blades. Meets the performance requirements established by the Florida

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY SAND TRAP LOUVERS.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY SAND TRAP LOUVERS. 25 YEARS OF EX C E L L E N C E 13.0 13.0 index INDEX SECTION TOPIC PAGE 13.1 Sand Trap Louver with Bird screen ASTL 3 13.2 Sand Trap Louver with Filter ASTL+F 4 13.3 Sand Trap Louver with Damper ASTL+D

More information

For us, it s not just business. It s personal.

For us, it s not just business. It s personal. For us, it s not just business. It s personal. CLIMATE CONTROL SERIES - SIMPLEX TANK MOUNTED Quiet operation. Heavy duty single and two stage high efficiency air compressors. Durable cast iron pumps for

More information

Galvanized Pipe. Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available.

Galvanized Pipe. Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available. Galvanized Pipe Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available. Angle rings are needed to secure connections. See pages

More information

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN

More information

1. ABMA 9 - Load Ratings and Fatigue Life for Ball Bearings. 2. ABMA 11 - Load Ratings and Fatigue Life for Roller Bearings.

1. ABMA 9 - Load Ratings and Fatigue Life for Ball Bearings. 2. ABMA 11 - Load Ratings and Fatigue Life for Roller Bearings. SECTION 23 74 13 - CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes modular factory fabricated air-handling units and accessories for indoor and outdoor installation.

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB OVERVIEW TYPE: GGB All composite construction Rigid extruded upvc aerofoil blade section Integral blade seals for low leakage operation Individual blades driven via reinforced styrene gear wheels in maintenance

More information

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers Life Safety Dampers Selection and Application Manual Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers May 2014 1 2 Table of Contents HOW TO USE THIS MANUAL DAMPER APPLICATION

More information

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

SCVO-3. Cabinet Unit Heater Options Booklet

SCVO-3. Cabinet Unit Heater Options Booklet SCVO3 Cabinet Unit Heater Options Booklet Cabinet Unit Heaters Options 2 CAT0070.dwg TABLE OF CONTENTS OPTION NUMBER Factory installed 0 2 3 7 8 9 20 2 22 23 24 26 27 28 29 Field Installed 4 & 5 6 8 9

More information

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING PLEASE READ AND SAVE THESE INSTRUCTIONS - 2 - INTRODUCTION TO THE BIG

More information

Johnson Air-Rotation Systems

Johnson Air-Rotation Systems AR Series TM Johnson Air-Rotation Systems Solution TM D Series TM FF Series TM 80/20 PR Series TM Johnson Air-Rotation systems announces a major addition to its product line, completing its line of high

More information

Portable filtration unit / 650 CFM (1100 M 3 H) Portable filtration unit / 1500 CFM (2550 M 3 H) For 2 arm configuration

Portable filtration unit / 650 CFM (1100 M 3 H) Portable filtration unit / 1500 CFM (2550 M 3 H) For 2 arm configuration Diversified Air Systems, Inc. Portable filtration unit / 650 CFM (1100 M 3 H) Portable filtration unit / 1500 CFM (2550 M 3 H) For 2 arm configuration Push-cart type unit Self cleaning by air pulsation

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

FIRE DAMPER APPLICATION GUIDE

FIRE DAMPER APPLICATION GUIDE FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire

More information

Outlet dampers for centrifugal fans DAMPER FEATURES PARALLEL BLADE DAMPER OPPOSED BLADE DAMPER REMOVABLE CASING DETAIL

Outlet dampers for centrifugal fans DAMPER FEATURES PARALLEL BLADE DAMPER OPPOSED BLADE DAMPER REMOVABLE CASING DETAIL PARALLEL BLADE OPPOSED BLADE REMOVABLE CASING DETAIL Outlet dampers for centrifugal fans FEATURES Rugged construction for long service. Choice of parallel or opposed vanes to best suit dampering requirements.

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

Portable filtration unit / 650 CFM (305 L/S) Portable filtration unit / 1500 CFM (710 L/S) For 1 or 2 arms configuration

Portable filtration unit / 650 CFM (305 L/S) Portable filtration unit / 1500 CFM (710 L/S) For 1 or 2 arms configuration Diversified Air Systems, Inc. Portable filtration unit / 650 CFM (305 L/S) Portable filtration unit / 1500 CFM (710 L/S) For 1 or 2 arms configuration 99.9% efficiency at 1 micron Cart type unit for welding

More information

product application guide

product application guide Understanding Fan System Effects Fan Application FA/101-99 product application guide A technical bulletin for engineers, contractors and students in the air movement and control industry. The air moving

More information

CFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115

CFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115 Air Circulators High Velocity Floor Fans Circulate Large Volumes of Air Product Specifications Size Spd HP HZ CFM/WATT @.0 SP AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3

More information

Tube Type Oil Skimmer Comparison

Tube Type Oil Skimmer Comparison Process Overview- Tube Type Oil Skimmers Oil flows down the face of the skimmer and into a sludge pan that is plumbed to a barrel. Model BG01 & BG34 or 6V Oil Skimmer 1.0 or 3/4 Diameter Collector Tube

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

The CLIPPER Solutions

The CLIPPER Solutions The CLIPPER Solutions 111 112 C51 6,5 Hp Ø 350mm 76kg Compact, robust and highly manoeuvrable machines designed for both wet and dry cutting of concrete and asphalt. Machine delivered without diamond blade.

More information

plenum slot diffusers

plenum slot diffusers light powered Redefine your comfort zone. www.titus-hvac.com dual-function smart logic light powered energy solutions Table of Contents PLENUM SLOT IFFUSERS products Plenum Slot iffusers Products... 4

More information

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options. Application and esign Thermal ispersion Air Measuring Station with VC-23 Control amper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

SECTION 233000 HVAC AIR DISTRIBUTION

SECTION 233000 HVAC AIR DISTRIBUTION 1320 / Talent Community Center 233000-1 HVAC AIR DISTRIBUTION SECTION 233000 HVAC AIR DISTRIBUTION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Ductwork. 2. Ductwork accessories. 3. Fans. 4. Air

More information

National System of Garage Ventilation s Engineering Guide

National System of Garage Ventilation s Engineering Guide National System of Garage Ventilation s Engineering Guide In designing a fume removal system, it is extremely important to determine the following: 1. Type of apparatus to be exhausted (i.e. gasoline,

More information

For us, it s not just business. It s personal.

For us, it s not just business. It s personal. For us, it s not just business. It s personal. HEAVY DUTY SERIES - VERTICAL TANK MOUNTED Quiet operation. Heavy duty two stage high efficient air compressors. All units factory set at 120-150psi. All units

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Operation and Installation Manual. Max Series

Operation and Installation Manual. Max Series Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

Make-Up Air Units. Direct-Fired Outdoor Model DFOA MUA-PRC001-EN. September 2000

Make-Up Air Units. Direct-Fired Outdoor Model DFOA MUA-PRC001-EN. September 2000 Make-Up Air Units Direct-Fired Outdoor Model DFOA September 2000 Introduction Why Use Trane Make-Up Air Units? To help relieve negative pressure inside commercial and industrial facilities, such as factories,

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

AESCO/MADSEN. Self-Erect Silos by AESCO/MADSEN

AESCO/MADSEN. Self-Erect Silos by AESCO/MADSEN AESCO/MADSEN Self-Erect Silos by AESCO/MADSEN AESCO/MADSEN manufactures two self-erecting silos called the WM-Series. The WM-50 has a 50-ton silo and the WM-80 has an 80-ton. The WM Series comes complete

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change

More information

DUMP TARP KITS MANUAL TARP KITS ELECTRIC TARP SYSTEMS MECHANICAL CRANK ARM TARP SYSTEMS

DUMP TARP KITS MANUAL TARP KITS ELECTRIC TARP SYSTEMS MECHANICAL CRANK ARM TARP SYSTEMS ELECTRIC TARP & MANUAL SYSTEMS DUMP TARP KITS MECHANICAL CRANK ARM TARP SYSTEMS MANUAL TARP KITS ELECTRIC TARP SYSTEMS MECHANICAL CRANK ARM TARP SYSTEMS MANUAL TARP KITS TRAILER TARP KITS PARTS & ACCESSORIES

More information

Air Handling Unit Fan Selection Guide

Air Handling Unit Fan Selection Guide Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4 Fan

More information

Model 222S (Galvanized receiver optional) AURORA. 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS

Model 222S (Galvanized receiver optional) AURORA. 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS Model 222S (Galvanized receiver optional) AURORA 220 Series SINGLE STAGE CONDENSATE AND BOILER FEED PUMPS WWW.AURORAPUMP.COM AURORA 220 Series Single Stage Condensate and Boiler Feed Pumps 2 Introduction

More information

Inmate Security Transport Vehicle (ISTV) Bid Specifications

Inmate Security Transport Vehicle (ISTV) Bid Specifications Inmate Security Transport Vehicle (ISTV) Bid Specifications 1.0 INTRODUCTION This specification describes the caging requirements for a 12-Passenger Van (Make/Model: 2013 Chevrolet Express C2500) to be

More information

MiniForce II Instruction Manual-8/05

MiniForce II Instruction Manual-8/05 The MINIFORCE II HEPA Air Filtration system is a dual speed HEPA-filtered negative air machine designed for removal of toxic mold, asbestos or other airborne contaminants during construction, renovation

More information

OVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.

OVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. Pick Smarter. Pick Better. Pick UNEX. Skatewheel (SW) Skatewheel Gravity Conveyor is ideally suited to convey lightweight packages and where operations require portable or temporary conveyor lines such

More information

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Central Station Air Handlers

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Central Station Air Handlers COMMERCIAL HVAC AIR-HANDLING EQUIPMENT Central Station Air Handlers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application

More information

Heavy Duty Industrial Air Compressors

Heavy Duty Industrial Air Compressors HEAVY DUTY SERIES - VERTICAL TANK MOUNTED All units mounted on air receivers rated at 200 psi and CRN approved for Canada. All units may be ordered with magnetic starter (Starter supplied loose). All units

More information

AURORA. 520 Series SINGLE STAGE SUMP PUMPS

AURORA. 520 Series SINGLE STAGE SUMP PUMPS AURORA 520 Series SINGLE STAGE SUMP PUMPS WWW.AURORAPUMP.COM AURORA 520 Series Single Stage Sump Pumps Capacities to 110 G.P.M. Heads to 40 Feet Temperatures to 180 F Introduction. Vertical extended shaft

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

F-900 HOPEC Bench Hood Framed Vertical Sash

F-900 HOPEC Bench Hood Framed Vertical Sash F-900 Series HOPEC Bench Hoods Product Features F-900 HOPEC Bench Hood Framed Vertical Sash The ISOLATOR HOPEC (Hand Operated Positive Energy Control) bench fume hood is based on the design of Jerry Koenigsberg*.

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

SPARE PARTS LIST AND ASSEMBLING GUIDELINE FOR EM 50 FAN

SPARE PARTS LIST AND ASSEMBLING GUIDELINE FOR EM 50 FAN SPRE PRTS LIST ND SSEMLING GUIDELINE FOR EM 50 FN Munters euroemme S.p.. Strada Piani, I-807 Chiusavecchia (Imperia) - Italy Tel. +39 083 5 Fax +39 083 5333 http://www.munters.com e-mail:info@munterseuroemme.it

More information

2016 INDUSTRIAL FAN CATALOG

2016 INDUSTRIAL FAN CATALOG 2016 INDUSTRIAL FAN CATALOG airkinglimited.com TABLE OF CONTENTS Introduction 2 Industrial Grade Quiet Floor Fans 3 Industrial Grade Quiet Pedestal Fans 4 Industrial Grade Quiet Wall Mount Fans 5 1/3 HP

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

Owner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING!

Owner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING! Heaters for the Harshest Environments Owner s Manual ISO 9001 EFX Explosion-Proof Exhaust Fan This manual covers installations, maintenance, repair and replacement parts. WARNING! READ ALL IMPORTANT NOTICES

More information

SECTION 32 31 13 CHAIN LINK FENCES AND GATES

SECTION 32 31 13 CHAIN LINK FENCES AND GATES SECTION 32 31 13 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Fence framework, fabric, and accessories. 2. Excavation for post bases. 3. Concrete foundation for posts

More information

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS. DESCRIPTION FEATURES

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS.   DESCRIPTION FEATURES TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: AHR18 THRU 60* DESCRIPTION This fan coil line offers the ultimate in application flexibility. The AHR (non-variable

More information

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022

More information

Duct Blower Cabinet Fans

Duct Blower Cabinet Fans Duct Blower Cabinet Fans INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This publication contains the installation, and maintenance procedures for standard units of the DB - Ceiling, Wall and Cabinet

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost

More information

Innovent LASER Packaged Fresh Air Conditioning Units

Innovent LASER Packaged Fresh Air Conditioning Units LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent

More information

SECTION 6. Glass Storefront Doors:

SECTION 6. Glass Storefront Doors: SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail

More information

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG Installation and Operating Manual Model F1800C Model F1800PG Model F180C Model F180PG Model F1806C Model F1806PG www.ipsystemsusa.com Contents Safety Warnings... Items supplied... Description... Installation...4

More information

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications INC Flexi-Sorb Noise Control Curtain System Versatile Flexible Easy To Install Durable Good Noise Reduction Economical Our Flexi-Sorb noise control curtain product line consists of flexible, durable acoustical

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

1300 MAXTRAK SPECIFICATION

1300 MAXTRAK SPECIFICATION CONE CRUSHER Crusher type: Liners: Standard concave: Lubrication: Adjustment: Control: Concave options: 1300 Automax Crusher. Manganese steel alloy mantle and concave. Medium Coarse. Pumped system having

More information

COMMERCIAL KITCHEN HOOD WORKSHEET / CHECKLIST

COMMERCIAL KITCHEN HOOD WORKSHEET / CHECKLIST TAYLOR BUILDING / ZONING DEPARTMENT 425 Papermill Rd. - P.O. Box 158 Taylor AZ. 85937 Phone (928) 536-7366 COMMERCIAL KITCHEN HOOD WORKSHEET / CHECKLIST Two copies of this worksheet / checklist must accompany

More information

Stock Fan Coils & Unit Heaters

Stock Fan Coils & Unit Heaters Complete solutions for fan coil applications Stock Fan Coils & Unit Heaters Engineered for flexibility and performance High Quality Fan Coils For Every Application McQuay fan coil units have earned a reputation

More information

DUCT SMOKE DETECTOR D4120

DUCT SMOKE DETECTOR D4120 Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity

More information

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete. LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and

More information

HVAC Control & Balancing Dampers Models VCD, MBD and RBD

HVAC Control & Balancing Dampers Models VCD, MBD and RBD HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* August 1 2013 HVAC Control and Balancing Dampers Commercial Control Dampers are used in buildings to regulate

More information

OPERATING & MAINTENANCE MANUAL

OPERATING & MAINTENANCE MANUAL 8720 LAMBRIGHT ROAD HOUSTON, TEXAS 77075 PHONE: (713) 987-0336, FAX: (713) 987-0355 www.acsi-us.com FORCED AIR 2000EC PORTABLE HEPA FILTRATION UNIT PART ORDER NUMBER: FA2000EC OPERATING & MAINTENANCE MANUAL

More information

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB SPECIFICATIONS CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB Page 1 Powerful VERTEX TM Complete Capture Design rivals the finest island hoods. Compact design allows the choice of many cooktop

More information

MEASURING SOLUTIONS. Ruskin Solutions for Measuring, Maintaining and Controlling Air

MEASURING SOLUTIONS. Ruskin Solutions for Measuring, Maintaining and Controlling Air R GO GREEN GO RUSKIN MEASURING SOLUTIONS Ruskin Solutions for Measuring, Maintaining and Controlling Air Ruskin Air Measuring Solutions Applications Chart Application Code Application Description MODEL

More information

DIRECT DRIVE PLENUM FAN (DDP)

DIRECT DRIVE PLENUM FAN (DDP) Our Expertise, Your Air-Moving Solution DIRECT DRIVE PLENUM FAN (DDP) PART# 0601720001_rev_A INSTALLATION, OPERATION & MAINTENANCE MANUAL Please read and save these instructions for future reference. Read

More information

OCA. FLUID COOLING Industrial & Mobile OCA Series

OCA. FLUID COOLING Industrial & Mobile OCA Series FLUID COOLING Industrial & Mobile Series FEATURES Young Radiator OCS Model Interchange American Industrial AOCS Interchange Hydraulic Circuits Machine Tool Cooling Gear Oil Cooling Lube Oil Cooling Process

More information

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce

More information