NEMA Manual Starters. 3.1 Starters and Switches
|
|
- Marsha Lilian Miles
- 7 years ago
- Views:
Transcription
1 MS Series, Single-Phase Starters.1 Product Overview Types B0, B0, Switches MS Series, Single-Phase Starters Type B100, Single- and Three-Phase Starters V5-T- V5-T- V5-T-6 V5-T-10 Type 9441, Reversing Drum Switches V5-T-15 Type B100, Single- and Three-Phase Starters Types B0, B0 Switches Volume 5 Motor Control and Protection CA E August V5-T-1
2 .1 NEMA Manual Starters Contents Description Types B0, B0, Switches MS Series, Single-Phase Starters Type B100, Single- and Three-Phase Starters Type 9441, Reversing Drum Switches Page V5-T- V5-T-6 V5-T-10 V5-T-15 Product Overview Eaton offers the most complete line of manual motor starters in the industry. Product offering includes manual motor starters and switches that cover single as well as three-phase motor applications. Application Description MS Motor Starter is a compact, versatile unit featuring heavy sliding contacts as well as quickmake and quick-break mechanism. B100 Manual Motor Starters can be used in single-phase applications rated hp at 40 Vac or hp at 0 Vdc. The starter can also be rated for three-phase applications up to 10 hp at 600 Vac. B0 and B0 Manual Motor Switches are available in two- or three-pole configurations rated at 0A. V5-T- Volume 5 Motor Control and Protection CA E August 015
3 .1 Types B0, B0 Switches Contents Description Types B0, B0, Switches Product Selection Wiring Diagrams Dimensions MS Series, Single-Phase Starters Type B100, Single- and Three-Phase Starters.... Type 9441, Reversing Drum Switches Page V5-T-4 V5-T-4 V5-T-5 V5-T-6 V5-T-10 V5-T-15 Types B0, B0, Switches Product Description Manual Motor Switches are available in two- or three-pole configurations rated at 0A. Optional NEMA 1 aluminum enclosure is supplied with a padlock guard for locking in the OFF or STOP position. Application Description Manual Motor Switches provide manual control of single- and three-phase motors where overload protection is not required or provided separately. Applications include: Fans Blowers Pumps Wood working equipment Machine tools Features Compact size Easy installation Simple operation Padlockable NEMA 1 enclosure available Standards and Certifications UL File No. E146654, Category NLRV CSA File No. LR71088, Class Instructional Leaflet Pub571 Volume 5 Motor Control and Protection CA E August V5-T-
4 .1 NEMA Manual Starters Product Selection When Ordering Specify number of manual motor switch Two-Pole B0AN Two-Pole NEMA 1 Enclosure B0BG Three-Pole B0AN Wiring Diagrams Manual Motor Switches without Overload Maximum Horsepower Ratings NEMA 1 10V 40V 480V 600V Open Enclosed Two-Pole Manual Motor Switches 5 B0AN B0AG B0BND B0BGD Three-Pole Manual Motor Switches 7-1/ 15 0 B0AND B0AGD B0AN B0BN B0AN L1 L T 1-Ph. Motor L1 L T T 1-Ph. Motor L1 L L T T T T -Ph. Motor V5-T-4 Volume 5 Motor Control and Protection CA E August 015
5 .1 Dimensions Approximate Dimensions in Inches (mm) B0AN (10.1) (8.) 1.0 (.0).8 (60.5) Approximate Shipping Weight 4 oz. (0.11 kg) B0BN and B0AN 1.1 (8.4).78 (96.0) (8.).8 (60.5).8 B0AG, B0BG, B0AG #6- Tapped Holes for Wall Plate.5 (57.) Approximate Shipping Weight 6 oz. (0.17 kg) 4.7 (119.9).0 (81.) Approximate Shipping Weight 14 oz. (0.40 kg) 4 #6- Tap 0.0 (5.1) Dia. Mtg. Holes (69.9) (6.0) 1.11 (8.) 0.06 (1.5).7 (57.7) 1.44 (6.6) 1.50 (8.1).75 (69.9) Holes 0.1 (.) Dia. Holes 0.7 (6.9) Dia. 0.5 (1.7) Front View Knockouts Back View End View 0.68 (17.) 0.91 (.1).41 (61.) 0.5 (1.7) x 0.75 (19.1) Knockout Each End Volume 5 Motor Control and Protection CA E August V5-T-5
6 .1 NEMA Manual Starters MS Series, Single-Phase Starters MS Series, Single-Phase Starters Product Description The MS Motor Starter is a compact, versatile unit featuring heavy sliding contacts as well as quickmake and quick-break mechanism Standard with large pressure type terminals, straight-through wiring and a trip-free handle mechanism The plug-in heater element is keyed to ensure proper positioning and an adjustable knob allows a setting of plus or minus ten percent of the nominal heater rating Application Description The MS Manual Motor Starter provides manual control and overload protection to singlephase motors. By utilizing the interchangeable heater elements, the starter can protect motors ranging from 0.40A up to 16.0A. Ideal for HVAC applications. Contents Description Types B0, B0, Switches MS Series, Single-Phase Starters Product Selection Accessories Dimensions Type B100, Single- and Three-Phase Starters.... Type 9441, Reversing Drum Switches Features Compact size Trip-free handle mechanism Keyed heater elements to ensure proper installation Starters available with red pilot light The operating handle of the enclosed units can be locked in the OFF position Enclosures are offered in NEMA 1,, 4 and 5 Hazardous locations cast aluminum enclosures are available rated for Type 7, Class I, Group D (vapors) and Type 9, Class II, Groups E, F an G (dust) Page V5-T- V5-T-7 V5-T-9 V5-T-9 V5-T-10 V5-T-15 Standards and Certifications UL File No. E19, Category NLRV CSA File No. LR940-6, Class Instructional Leaflet IL1987G V5-T-6 Volume 5 Motor Control and Protection CA E August 015
7 .1 Product Selection When Ordering Specify number of manual motor starter Heater pack selection Any required accessories Heater coil selection according to the motor full load current requirements MS Series Starters MS Series, Single- Phase Starters Switch and Pilot Light Mounted on Flush Plate Open Type of Poles Horsepower Voltage /40V, 77 Vac MST01 Flush Plate (No Enclosure Included) Note 1/4 10/40 Vdc MST01 1/4 Vdc MST /40V, 77 Vac MST0 1 10/40 Vdc MST0 1/4 Vdc MST0 of Poles Flush Plate Type Voltage 1 1 General purpose Switch only MST01FN Switch with pilot light MST0FN1P 1 Stainless steel Switch only MST01DN Switch with pilot light 1 Does not include heater. Select heater from tables on Page V5-T-8. MST01DN1P Switch only MST0DN Switch with pilot light MST0DN1P Volume 5 Motor Control and Protection CA E August V5-T-7
8 .1 NEMA Manual Starters Starter and Pilot Light Mounted in Type 1 Enclosure Starter, Hand/Auto and Pilot Light Type 1 Enclosure Waterproof Type, 4 and 5 Hazardous Location Type 7D, 9E, 9F and 9G Typical Heater Heater Element Installation Enclosed Types of Poles Enclosure Type Product Feature 1 1 General purpose Starter only MST01SN Type 1 Starter with pilot light MST01SN1P Starter only MST0SN General purpose NEMA 1 Heater Selection for MS Starters Notes Starter with pilot light Starter with Hand/Auto switch and pilot light 1 Does not include heater. Select heater from table above. For OFF function, use OFF position on starter toggle switch. Type 7D = Type 7, Class I, Group D; Type 9E, 9F and 9G = Type 9, Class II, Groups E, F and G. MST0SN1P MST0RN1PH 1 Waterproof Through hub MST01AH Type, 4 and 5 Through hub MST0AH 1 Hazardous location Through hub MST01EH Types 7D, 9E, 9F and 9G Through hub MST0EH MSH-5A MSH1-A.7.95 MSH-4A MSH8-8A MSH-55A MSH1-45A.96.7 MSH-7A MSH9-7A MSH-61A MSH1-6A.8.59 MSH4-1A MSH10-6A MSH-67A MSH1-7A MSH4-5A MSH11-7A MSH-74A MSH1-9A MSH5-0A MSH1-9A MSH-81A MSH-1A MSH5-5A MSH14-A MSH-89A MSH-A MSH6-0A MSH15-6A MSH-98A.00. MSH-5A MSH6-6A MSH17-1A MSH1-1A.4.47 MSH-8A MSH7-A MSH18-6A MSH1-A MSH-1A MSH8-0A V5-T-8 Volume 5 Motor Control and Protection CA E August 015
9 .1 Accessories MS Accessories Description Pilot light kit (NEMA 1 enclosure and flush plates) Box, 1 unit (NEMA 1 enclosure) Cover, 1 unit (NEMA 1 enclosure) Flush plate, 1 unit (steel) Flush plate, 1 unit (stainless steel) Handle guard (padlockable for NEMA 1 enclosure and flush plates) Dimensions Approximate Dimensions in Inches (mm) MS Motor Starter Toggle Operated Open Units 0.6 (9.1) Dia. 1.6 (4.5).7 (69.1) 0.06 (1.5) 0.11 (.8) Height of Handle 0.19 (4.8) 0.1 (7.9).8 (8.) 1.5 (1.8) 0 Typ (40.1) 0.75 (19.1).81 (96.8) 1.91 (48.5) 0.7 (18.5) 1.70 (4.) 0.1 (7.9) 0. (5.6) 1.19 (0.) 1.64 (41.7).8 (60.5) Tap Hazardous Location (Cast Aluminum).94 (100.1) 0.75 (19.1) Pipe Tap 0.81 (0.6) 0.0 (7.6) Dia. Lockout Hole.5 (88.9).6 (66.8) 0.4 (8.6) Dia. () Mounting Holes 5.88 (149.4) 6.7 (170.7) 0.44 (11.) MSPT MS1BN MS1CN MS1FN MS1DN MSLG Flush Plates 1.8 (5.1) 4.5 (114.).75 (69.9) Mounting Purposes () Holes 1.64 (41.7) 1.06 (6.9) (8.) (16.8) Handle Guard 0. (5.6).5 (57.) 0.1 Indicating Light (7.9) 1 Unit Watertight (Cast Aluminum).6 (9.) 0.75 (19.1) 0.75 (19.1) Pipe Tap.91 (7.9) 1.5 (8.6) 5.1 (10.) Type 1 Enclosure (Boxes and Covers) 1 Unit.8 (60.5) (10.4) (9.6) 4.16 (105.7) 0.0 (5.1) Diameter () Mounting Hole 0.55 (14.0).06 (77.7) Indicating Light Handle Guard 1.64 (41.7) 0.78 (19.8) 0.4 (8.6) 1.5 (8.9) 5.81 (147.6).8 (8.).8 (71.9).55 (64.8).47 (6.7).11 (5.6) 1.97 (50.0) Volume 5 Motor Control and Protection CA E August V5-T-9
10 .1 NEMA Manual Starters Type B100, Single- and Three-Phase Starters Type B100, Single- and Three-Phase Starters Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 40 Vac or hp at 0 Vdc. The starter can also be rated for three-phase applications up to 10 hp at 600 Vac. There are two methods of operation for the B100 Manual Starter. It can be ordered with a toggle switch operator or a START/STOP pushbutton operator. Application Description The B100 family of Manual Motor Starters provides manual control, as well as overload protection, to both single-phase and three-phase motors. The starter protects motors up to 8.9A singlephase and 6.8A three-phase with the appropriate heater selection. Contents Description Types B0, B0, Switches MS Series, Single-Phase Starters Type B100, Single- and Three-Phase Starters Product Selection Accessories Options Technical Data and Specifications Dimensions Type 9441, Reversing Drum Switches Features Includes three-pole bimetallic overload relay Straight-through wiring Field mounted auxiliary contacts Available in NEMA 1, 4, 7, 9 and 1 enclosures with toggle operation (NEMA 1 enclosure for pushbutton operator) Standard with a lockout device to lock motor in the OFF position Page V5-T- V5-T-6 V5-T-11 V5-T-1 V5-T-1 V5-T-1 V5-T-1 V5-T-15 Standards and Certifications UL File No. E19, Category NLRV CSA File No. LR940-6, Class (Open Starters) CSA File No. LR , Class (Closed Starters) Instructional Leaflet IL14890 V5-T-10 Volume 5 Motor Control and Protection CA E August 015
11 .1 Product Selection When Ordering Specify number of Starter with application modifications Toggle Operated Type 1 Enclosure Heater pack selection a three-phase starter requires three heaters, and a single-phase starter requires two heaters Any required accessories Toggle and Pushbutton Operated Starters Enclosed NEMA Size Open Type Toggle Handle 4 NEMA 1 General Purpose 4 Heater Selection Single-Phase Enclosed Starters 5 Maximum Fuse Amps NEMA 4 Watertight, Stainless Steel 1 4 Notes 1 One 1 in chrome hub supplied on each end. NEMA 7D = NEMA 7, Class I, Group D. NEMA 9E, 9F and 9G = NEMA 9, Class II, Groups E, F and G. Tapped for 1 in conduit on each end. 4 Starter does not include heaters. Select catalog numbers of heaters from table on Page V5-T-1. 5 Single-phase starters require two overload heaters. NEMA 7D, 9E, 9F and 9G for Hazardous Locations NEMA 1 Dust-Tight 4 4 Type B100 Non-Reversing Two-Pole (For Single-Phase Motors and DC) M-0 B100M0B B100S0B B100W0B B100U0B B100J0B M-1 B100M1B B100S1B B100W1B B100U1B B100J1B Type B100 Non-Reversing Three-Pole (For Polyphase Motors) 4 M-0 B100M0C B100S0C B100W0C B100U0C B100J0C M-1 B100M1C B100S1C B100W1C B100U1C B100J1C Maximum Fuse Amps Maximum Fuse Amps FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH1 Volume 5 Motor Control and Protection CA E August V5-T-11
12 .1 NEMA Manual Starters Heater Selection Three-Phase Enclosed Starters Accessories Type B100 Starters Options Maximum Fuse Amps Modifications Description Suffix Pushbutton operator (open and NEMA 1 only) A Without lockoff (open only) X Maximum Fuse Amps Notes 1 Single-phase starters require two overload heaters. Three-phase starters require three overload heaters. Add suffix letter to starter catalog number Example: B100MOCA. FH Series heaters are for Type B100 manual motor starters. Heater element selection is based on motor nameplate s listed full load amperes. Trip rating of this series of elements is 15% of minimum motor full load amperes listed for the element. When motor and overload relay are in the same ambient and the service factor of the motor is 1.15 to 1.5, select heaters from the heater selection table. If the service factor is 1.0 or less (including zero), or a maximum of 115% protection is desired, select a heater one size smaller than indicated for the amperage range required. Maximum Fuse Amps FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH FH0 Description Field Mounting Kits 1NO elect. auxiliary 1NC elect. auxiliary Red pilot light 10/60 (NEMA 1 enclosure only) Red pilot light 08-40/6 (NEMA 1 enclosure only) Red pilot light 480/60 (NEMA 1 enclosure only) B1A B1B LK-1 LK- LK-6 V5-T-1 Volume 5 Motor Control and Protection CA E August 015
13 .1 Technical Data and Specifications Type B100 Starters NEMA Maximum hp for AC Ratings 1 Maximum hp for DC Ratings Size 10 Vac Vac Vac 115 Vdc 0 Vdc Two-Pole, Single-Phase M / M-1 1-1/ Three-Pole, Three-Phase M-0 5 M-1 7-1/ 10 Dimensions Approximate Dimensions in Inches (mm) Type 1 Enclosed 7.59 (19.8) 0.6 (16.0) 1.5 (1.8) 4.7 (119.9).6 (59.9) OFF 0. (5.6) Dia. 4 Mtg. Holes.5 (8.6).50 (6.5) 1.05 (6.7) 6.00 (15.4) 1.6 (41.4) 1/ x /4 Conduit K.O. in Each Side 1/ x /4 Conduit K.O. in Bottom and in Top End 1.0 (5.9) 4.98 (16.5).98 (101.1) 1.0 (5.9) 0.9 (.4) 0.9 (.4) Type 4 Enclosed.56 (65.0) 9.19 (.4) 0.17 (4.) Note 1.50 (8.1) 5.1 (10.).00 (76.) 0.09 (.) (58.1) 5.00 (17.0) 8.8 (10.) 6.00 (15.4).05 (5.1) 0.6 (16.0) 1 Ratings up to hp, three-phase are suitable for group fusing. Volume 5 Motor Control and Protection CA E August V5-T-1
14 .1 NEMA Manual Starters Approximate Dimensions in Inches (mm) Type 7 and 9 Enclosed Type 1 Enclosed 7.1 (181.1).56 (90.4).56 (65.0) 5.1 (10.) 5.00 (17.0) 0.7 (6.9) 1.06 (06.) 6.0 (15.) 5.1 (10.) 10.5 (60.4) OFF ON 8.5 (09.6) 4.06 (10.1) 8.8 (1.9) 4.19 (106.4) 0.41 (10.4) Slot Req'd (.4) 1.5 (8.1).0 (76.) 8.8 (10.) 9.41 (9.0) 1 (5.4) NPSK Holes 1.8 (5.1) 0.50 (1.7) 0.88 (.4) 6.0 (15.4) Open, Non-Reversing Starter /16- Mounting Screw 5.8 (14.1) 5.84 (148.) 6.1 (160.) 7.77 (197.4). (59.) 4.78 (11.4) 5.97 (151.6).19 (81.0) 4.59 (116.6) V5-T-14 Volume 5 Motor Control and Protection CA E August 015
15 .1 Type 9441, Reversing Drum Switches Type 9441, Reversing Drum Switches Application Description Features These drum switches are designed primarily for use with single-phase and squirrel cage, single-speed reversible motors which may be connected directly across-the-line. Typical applications would be hoists and machine tools. Compact size Front mounting easily installed Terminals front accessible slanted 45 for extra convenience Captive pressure clamps on terminal screws back off with screw no prying with screwdriver necessary Choice of operators Large Lever Knob Orientation of operator independent of legend 60 positioning in -1/ increments pointer remains oriented to legend Field convertible from maintained to momentary operation Replaceable, large volume, silver plated contacts Oiltight machine cavity or surface mounting types Modern attractive appearance Contents Description Types B0, B0, Switches MS Series, Single-Phase Starters Type B100, Single- and Three-Phase Starters.... Type 9441, Reversing Drum Switches Product Selection Wiring Diagrams Dimensions Operation All of the operators may be rotated 60 in -1/ increments without losing the indication of the drum position. A red-lined pointer is permanently orientated to the legend markings and clearly indicates the selected drum function regardless of the selected setting for the operator. This enables the user to offset the operator to afford the most comfortable operating position. This is accomplished simply by loosening and retightening one screw. Page V5-T- V5-T-6 V5-T-10 V5-T-16 V5-T-17 V5-T-17 Standards and Certifications UL File No. E716, Category NLRV CSA Guide No. 184-N-1.1A, Class 11 Volume 5 Motor Control and Protection CA E August V5-T-15
16 .1 NEMA Manual Starters Product Selection When Ordering Specify number Type DB1 Flush Mount Standard Lever Type DB and DD Surface Mounting Standard Lever Type DB1 Flush Mount Knob Operator Type DB and DD Surface Mounting Knob Operator Reversing Drum Type without Overload Relay Maximum Horsepower Surface Mounting General Purpose NEMA 1 Notes 1 These devices are field convertible from maintained both positions to momentary both positions. These devices are field convertible from maintained FORWARD and momentary REVERSE to momentary FORWARD and maintained REVERSE. Flush or Cavity Mounting (Oiltight Mounting on Sizes DB and DD) Lever Lever Three-Phase Single-Phase DC Type of Operator Knob Operator Knob 00 0V V 115V 0V 115V 0V Size Operation Three-Pole 1-1/ 1 1 DB 1 Maintained H H H H75 Maintained and 9441H H7 9441H76 Momentary 5 1-1/ 1 1 DB Maintained H5 9441H H47 Maintained and 9441H H H H50 Momentary 5 7-1/ 1-1/ DD 1 Maintained H H H88 7-1/ 10 5 DD Maintained H H6 9441H6 V5-T-16 Volume 5 Motor Control and Protection CA E August 015
17 .1 Wiring Diagrams Single-Phase Motors L S1 L1 A1 S1 L T8 L Arm Universal S A A1 A S T5 T5 T8 T5 1 L1 5 T8 Split- Phase L T8 L1 T8 Dimensions Approximate Dimensions in Inches (mm) Surface Mounting 4 6 L T4 T8 T4 T5 Split- Capacitor Capacitor-Start Three-Wire Four-Wire Repulsion-Start Induction, Repulsion, Repulsion-Induction D A E F B T5 T4 T4 T5 Dimensions and Shipping Weights Size Type of Operator C Wide A HIgh B Deep C Polyphase Motors L1 T L TT L T M Three-Phase Three-Wire DC Motors L1 A L F1 F1 F 1 A1 Shunt Field 4 S1 S1 S 5 6 S Series Field A1 A Arm F For Shunt Motor Add Jumper Series, Compound, Shunt Cavity Mounting D A E B Panel Cutout Cavity Mounting.00 (76.) Size DB1 and DB.5 (8.6) Size DD1 and DD Mounting D F C.50 (88.9) Size DB1 and DB.88 (98.6) Size DD1 and DD Mounting E Lever F Shipping Weight Lbs (kg) Surface Mounting DB1 and DB Lever.50 (6.5) 5.88 (149.4) 4.8 (111.).00 (50.8).5 (57.) 1.88 (47.8).0 (1.4) Knob.50 (6.5) 5.8 (16.7).00 (76.).00 (50.8).5 (57.) 1.8 (5.1).0 (1.4) DD1 and DD Lever.8 (85.9) 6.88 (174.8) 4.75 (10.7).6 (66.8).75 (69.9).00 (50.8) 4.0 (1.8) Knob.8 (85.9) 6.5 (158.8).6 (9.).6 (66.8).75 (69.9) 1.8 (5.1) 4.0 (1.8) Cavity Mounting DB1 and DB Lever 4.00 (101.6) 4.75 (10.7) 5.00 (17.0).50 (88.9) 4.00 (101.6) 1.88 (47.8).0 (1.4) Knob 4.00 (101.6) 4.50 (114.) 4.50 (114.).50 (88.9) 4.00 (101.6) 1.8 (5.1).0 (1.4) DD1 and DD Lever 4.50 (114.) 5.75 (146.1) 5.5 (1.4) 4.00 (101.6) 4.50 (114.).00 (50.8) 4.0 (1.8) Knob 4.50 (114.) 5.1 (10.) 4.6 (117.6) 4.00 (101.6) 4.50 (114.) 1.8 (5.1) 4.0 (1.8) Volume 5 Motor Control and Protection CA E August V5-T-17
Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015
Hubbell Industrial Controls, Inc. Class 58 Drum Controller Catalog & Price List November 205, Replaces Jan 205 Class 58 Drum Controllers start, stop and change the speed and/or rotating direction of reversible
More informationMotor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87
Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................
More informationContactors Low Voltage
00Motor Starters and April 06 Sheet Motor Starters and ContactorsLow Voltage.0- ContactorsLow Voltage Contents Motor Starters and ContactorsLow Voltage Manual Motor Control MS Starter with Hand/Auto......................................-
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationSolid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
More informationBolted contact switches. Pringle switches
Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationMiniature Circuit Breakers and Supplementary Protectors
Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationManual Starters and Switches Selection Guide
Selection Guide Class 510, 511, 51, 601 CONTENTS Description.....................................................Page Class 510, 51 Type F Fractional Horsepower Manual Starters............... Class 510,
More informationDefinite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationTERMINAL MARKINGS AND CONNECTIONS PART WINDING START
TERMINAL MARKINGS AND CONNECTIONS PART WINDING START NEMA NOMENCLATURE 6 LEADS 7 7 3 9 8 Delta 3 9 8 Wye OPER. 9 MODE L L L3 OPEN 7 START 3 7,8,9 T T T3 T7 T8 T9 RUN,7,8 3,9 3 8 MOTOR LEADS 3 7 Double
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationMR221-MR222 Heavy Duty Geared Limit Switches, CE Approved
MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MICRONOR automation components Product MICRONOR MR221 and MR222 series Heavy Duty Geared Limit Switches are for use in the most demanding industrial
More information9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationComparison of NEMA and IEC schematic diagrams
Cross-Reference MZ081001EN Comparison of NEMA and IEC schematic diagrams General With the increasing emphasis on globalization, many industries are now looking to all parts of the world to produce, market,
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationTP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12
Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationMotor Accessories. C-Face Kits for Field Conversion NEMA AC Motors
C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,
More informationEVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.
EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce
More informationSquare D Safety Switches
Square D Safety Switches Power isolation solutions for daily activities and emergencies TM Make the most of your energy SM Square D Safety Switches Setting the standard for perfomance, quality, and reliability
More informationElectronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationPowers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationTorqPlus TM Electric Valve Actuators and Controls
TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,
More informationSAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationSeries 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS
Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation
More informationMedium Voltage Motor Control Assemblies
Medium Voltage Motor Control Assemblies Arc Resistant AMPGARD.1 Product............................................. 2 Application........................................... 2 Features, Benefits and Functions...................................
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationHPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationCable/Conduit Conversion
Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationWe will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
More informationHow To Test A Power Switch On A Power Supply
transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability
More informationETZGAR CONVEYOR COMPANY Controls Section v12.05
Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed
More informationSecondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationSection 5. IEC Power Devices. www.geindustrial.com Control Catalog 5-1
Contactors Overview ()...5-3 Mini Contactors () Overview...5-4 Features and Benefits...5-5 Accessory Features...5-6 Product Offering...5-7 Product Number Selection Instructions...5-7 Product Descriptions...5-8
More informationHow To Protect A Motor From Overcurrent
Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationSample - No Commercial Use
COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationBuilding an Auto-Start Rotary Three Phase Converter. by: Matt Isserstedt
Building an Auto-Start Rotary Three Phase Converter by: Matt Isserstedt Disclaimer: Electrical wiring is inherently dangerous. No warranties are issued or implied about the safety or success of this system.
More informationP70, P72, and P170 Series Controls for Dual Pressure Applications
P70, P72, and P170 Series Controls for Dual Pressure Applications Product Bulletin Code No. LIT-125455 Issued August 30, 2012 Supersedes September 1, 2000 The P70, P72, and P170 controls for dual pressure
More informationPlugs and Receptacles
Plugs and Receptacles Industrial Heavy Duty Interlocked Application and Selection Applications: Where extra protection is a requirement; interlocked units provide dead front receptacles; connection cannot
More informationLow Voltage Fuses For Motor Protection
Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.
More informationMCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationEquipment. Metering. Metering Equipment 1. Contents
1 October 00 Utilities Servicing Texas Metering Equipment Contents Page Logic ing System.................................... Product Selection by Utility CenterPoint Energy (Reliant & HL&P).............................
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationFractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications
DC3 DC Drives Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications The Reliance Electric DC3 family of drives provides cost-effective variable speed control and operates
More informationVariable Transformers Product Design & Engineering Data
Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,
More informationPressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial
sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with
More informationType Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1
Power PCB Relay G2R Creepage distance of 8.0 mm (0.31) min. between coil and contact. Dual-winding latching type available. Plug-in and quick-connect terminals available. High sensitivity (360 mw) and
More informationSPECIFICATIONS. S&C Switch Operators Type PM SPECIFICATION BULLETIN 669-31. For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear
S&C Switch Operators Type PM Outdoor Distribution For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth
More informationEXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
More informationBaldor Electric Position on DOE Small Motor Rule
Baldor Electric Position on DOE Small Motor Rule WP0035 WP0034 Page 1 of 6 US Integral DOE Small HP Motor Rule Rule Baldor Electric Position on DOE Small Motor Rule 10/28/14 On March 9, 2010 the US Department
More informationSpecifying a Variable Frequency Drive s
Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable
More informationVertical Break Parallel (VBP) / Vertical Break Slant (VBS)
August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers
More informationThe Ultimate Truck Stock Motor
The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent
More informationIMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.
QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your
More informationSQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationIRRIGATION PUMPING Table of Contents - Section 900
IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationDC disconnects for solar photovoltaic installations. Connecting the. power of the sun
DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these
More informationFLB Series Circuit Breakers and Enclosures
FLB Series Circuit Breakers and s Applications: FLB circuit breakers and enclosures are used: F service entrance, feeder branch circuit protection f lighting, heating, appliance and mot circuits In areas
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationAC METRIC (IEC) MOTORS THREE PHASE
AC METRIC MOTORS These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools,
More informationTS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
More informationSolid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More information98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.
81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX
More informationShort Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
More informationSolid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In
More informationType 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
More informationComponents for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationNumber 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why