1 Definite Purpose Control Index Description Page Number General Application and Features... Pole AC Contactors - DP..., and Pole Contactors - DP and DP... Two Pole Contactors Mechanically and Electrically Interlocked - DP... Modifications and Parts... Engineering Data... 6
2 DP - Definite Purpose Control AC Contactors Application Definite Purpose Contactors are intended for use in applications where the control requirements are well defined. They are not recommended for general industrial use. As a magnetic motor controller, they are inductively rated for both maximum continuous current and maximum locked rotor current Resistive ratings apply to resistive heating applications only. Joslyn Clark definite purpose contactors have been specifically designed for use with air conditioning, heating and refrigeration control equipment. They are suitable for other non cycling duty applications requiring reliable low cost switching. Low Coil Inrush and Sealed Provides maximum efficiency, permitting potential cost savings on transformer requirements. This efficient magnet system assures clean pick-up and drop-out without chattering when subjected to slowly rising and slowly decreasing voltages. Versatile Operating Positions Joslyn Clark pole contactors are designed to operate effectively in the vertical, horizontial or tabletop mounting positions. This gives design engineers maximum versatility for designing low cost systems. Interchangeable Along with being compact in size, the mounting plate is designed to facilitate proper alignment and interchangeability with practically all competitive pole contactors. Also, the low v-a permits direct interchangeability without requiring a transformer change. Terminals As an optional feature, Joslyn Clark contactors can be supplied with pressure clamp terminals which are UL Recognized for field connections of # through #8 copper wire. They may also be supplied with box lugs for # through # Al/ Cu wire. Up To A-C Rating The pole contactors have been designed with the customer in mind. They provide clearance between terminals permitting total utilization of all quick connects without requiring special insulation between terminals on equipment rated up to volts.
3 DP - Definite Purpose Control Pole Contactors - DP, and Ampere (Discount Schedule JC) DP Amp. Ratings FLA Res. LRA 6 / 8 / 8 / 8 / 8 Model Number DPC- * DPC- * DPC- * DPC- * AC Contactors A-668A- * $.. A-668A- * 9.. A-666A- *. A-66A- *. DPC- * A-66A- * 6.., & Pole Contactors - DP, & Amp. (Discount Schedule JC) Amp. Rating Locked Rotor Amps. Poles FLA Res V 8V V Model Number DPC- * A-99A- * 9.. DPC- * A-9A- *.. DPC- * A-96A- * 6.. DPC- * A-9A- *.. DPC- * A-9A- * 6.. DPC- * A-9A- * 6.. DP 8 DPC- * A-9A- * 6.. DPC- * A-9A- * DPC- * A-9A-- * 68.. DPC- * A-9A- * DPC- DPC- * A-96A- A-98A- * DPLC- * A-96A-* 9. Ordering Information & Pole Contactors - DP and 6 Amp. (Discount Schedule JC) DP Use complete catalog number. Replace the (*) with a suffix from the Coil Table. Example: DPC- (A-9A-) is a pole ampere, contactor with a Volt, /6 z Coil. Amp. Rating Locked Rotor Amps. FLA Res V 8V V Engineering Data- Page 6 Modification Data- Page Note: - comes with cover Discount Schedule JC & Poles Model Number Number DPC- * DPC- * DPC- * DPC- * DPC6- * DPC6- * DPC6- * DPC6- * Coil Table / 6z Voltage 8-8 Model No. Suffix Price Cat.No.Suffix DP DP DP... Factory Factory. Factory Factory 8.
4 AC Contactors Definite Purpose Control - DP Reversing Contactors - Mechanically & Electrically Interlocked DP - Bulletin, & Amp. DP Current Ratings Maximum Phase orsepower Ratings No. of Amp. Rating Locked Rotor Amps. General Duty Jogging Duty Aux. Ind. Res. V 8V V V V 6/V V V 6/V Model No. No. Contacts Price 8 6 / / / / / DPC- * DPC- * DPC- * A-A- * A-A- * A-A- * $ Mechanically and electrically interlocked contactors for low cost motor reversing applications such as hoists, doors, gates, etc.. Standard assembly includes mechanical interlock with two SPDT auxiliary contacts for electrical interlocking. Four additional auxiliary contacts may be factory added. Two may be field added. Approvals Underwriters Laboratories, Inc. recognized component for air conditioning, refrigeration and resistance heating equipment. File number E69, Section. Guide number NLDX. Use jogging duty rating on full-voltage magnetic controllers for plug-stop, plug-reverse and jogging duty regarding repeated interruption of stalled motor current or repeated closing of high transient currents encountered in rapid motor reversal beyond five openings or closings per minute or more than ten in a ten minute period. Canadian Standards Associations (CSA) Guide 6-E-. Class File 86- Ordering Information Use complete catalog number. Replace the (*) with the suffix from the coil table. Example: DPC- (A-A- ) is a Phase, amp., reversing contactor withv, /6 Z coil and SPDT auxiliary. Engineering Data Page 6. Modification Page. Coil Table /6z Voltage 8-8 Model No. Aux. Aux 8 CC CC CC 8CC Cat. No. Aux. Aux. 6 Discount Schedule JC
5 Modifications and Parts Definite Purpose Contactors-DP s DP, DP, DP, DP, DP, and DPS Accessories & Parts Kits Description SPDT Auxiliary Contact Kit N.O. Auxiliary Contact Kit N.O. & N.C. Auxiliary Contact Kit Contact Cover Pressure (Box) Lug Kit (Contains Lugs) DP, & Ampere A-6A- A-68A $.. DP, DP,, & Ampere KP-C A-6A- A-68A $ DP & 6 Ampere KDP- KDP- $. 6. Discount Schedule JC Replacement Coil Kits Discount Schedule JC Description DP, DP, & Ampere Number Price DP & 6 Ampere V, /6z 8-V, /6z V, /6z V, /6z 8V, /6z V, 6z KTB- KTB- KTB- KTB- KTB- KTB-6 $ CDP- CDP- CDP- CDP- CDP-8 CDP- $ Field Modifications Cat. No. Price Discount Schedule Enclosure Kit P6E- $8. JC Notes:. Additional modifications may be selected from NEMA P Section C page C. JC Discount Schedule for KP-C. Discount Schedule JC
6 DP-Definite Purpose Control Engineering Data Pole Contactors, DP Dimensions (Approximate) Coil /6z Max. Inrush Max. Sealed Pick-up D-C Resistance Ohms Coil insulation - Class B Coil connections - Double male /" quick connect Maximum ambient - o F & Pole Contactors - DP Dimensions (Approximate) Coil /6z Inrush Sealed Pick-up D-C Resistance Ohms Pole Contactor - DP Dimensions (Approximate) Coil Characteristics Inrush Sealed mtg. holes/ slots for # screws.9 Approvals Underwriters Laboratories, Inc. recognized component for air conditioning, refrigeration, and resistance heating equipment. File Number #E69. Guide Number NLDX. Canadian Standards Associations (CSA) Guide Number 6-E., File Number LX
7 DP-Definite Purpose Control Engineering Data Dimension - DP (Two -Pole Mechanically & Electrically Interlock Contactors) Typical wiring diagram for Electrically held Reverser using Mechanically Interlocked Push Buttons. Electrically eld Contactors and Mechanically Interlocked Pushbuttons Using Two SPDT Auxiliary Contacts. Four additional auxiliary contacts may be factory added. Two may be field added. Coil Characteristics Coil /6z 8- Inrush Sealed Pick-up Coil insulation - Class B Coil connections - Double male /" quick connect Maximum ambient - o F D-C Resistance Ohms Approvals Underwriters Laboratories, Inc. recognized component for air conditioning, refrigeration and resistance heating equipment. File number E69. Guide number NLDX. Canadian Standard Association (CSA) Guide number 6-E., File number LX86-9.
CATALOG #250 WWW.DANAHERSPECIALTYPRODUCTS.COM
CATALOG #250 WWW.DANAHERSPECIALTYPRODUCTS.COM TABLE OF CONTENTS Vacuum Control... Low Voltage, Medium Voltage... A NEMA Control - Heavy Duty... TM, 5000... B NEMA Control - General Duty... HP... C Pilot
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationClass 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015
Hubbell Industrial Controls, Inc. Class 58 Drum Controller Catalog & Price List November 205, Replaces Jan 205 Class 58 Drum Controllers start, stop and change the speed and/or rotating direction of reversible
More information3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C
41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationUS Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationSolid State Timers Type F
Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationAP/UP, AP/MIL Series. Magnetic Circuit Protectors
AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Specifications Decision Tables 71 72 75 76 77 78 79 AP/UP, AP/MIL Series Hydraulic
More informationIndustrial Control Power Transformers
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
More informationHow To Protect A Motor From Overcurrent
Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................
More informationInstallation Instructions
H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More information9 Control Equipment. Control Button Series 8082
9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements
More informationDefinite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
More informationReplacement Parts. Starters and Contactors AC Coils. Selection. Ordering Information
Starters and Contactors AC Coils Ordering Information 4th character of starter or contactor catalog number indicates model. 17 CONTROL AC Coils For Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43,
More informationSentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationpicomax The Pluggable Connection System
picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable
More informationHeavy Duty Control. Catalog Numbering System. General 8/47. Siemens Industry, Inc. Industrial Controls Catalog. 48 Overload Size
Heavy Duty Control Catalog Numbering System 48 Overload Size A B Frame A Frame B T ESP200 3 3 Phase Single Phase 00,, 20 or 30 Selectable Current Range A 0.2 B 0.7 3.4 Reset C 3 2 D. 22 E 40 F 3 2 G 2
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationType MG-6 Multi-Contact Auxiliary Relay
Type MG-6 Multi-Contact Auxiliary Relay Instruction Leaflet: 41-753.1 N Effective: August 2008 Supersedes 41-753.1 M, Dated December 1999 ( ) Denotes Change Since Previous Issue Device Number: 94X, Y,
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationRelays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules
CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN
More informationOverload Relay Heater Tables
Overload Relay Tables of Elements for Overload Relays Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average values,
More informationSKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
More informationData Sheet. Electro-mechanical counters Hengstler 800 series
Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from
More informationDistribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
More informationTP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12
Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationSingle Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationFire Pump Controllers Remote Alarm Panels
Fire Pump Controllers Remote Alarm Panels Remote Alarm Panels 1.8 Remote Alarm Panels FDAP-M Electric... DFDAP-M Diesel... Product Specifications... 2 6 9 Features 1-1 DFDAP-M / FDAP-M Remote Alarm Panel
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationGuide. Hi-TECH UCA CONTACTORS & HUBBELL SPECIAL PURPOSE CONTACTORS. Ordering. Hubbell Contactor Range SECTION 2 HUBBELL CONTACTOR RANGE
Hubbell Contactor Range SECTION 2 HUBBELL CONTACTOR RANGE HiTECH UCA CONTACTORS & HUBBELL SPECIAL PURPOSE CONTACTORS HiTech Contactors up to 110kW Fully comply with BS EN 6094741 5 sizes up to 110kW Designed
More informationSKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationP70, P72, and P170 Series Controls for Dual Pressure Applications
P70, P72, and P170 Series Controls for Dual Pressure Applications Product Bulletin Code No. LIT-125455 Issued August 30, 2012 Supersedes September 1, 2000 The P70, P72, and P170 controls for dual pressure
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationSPEEDFAX TM 2011 Disconnect Switches Contents
SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection
More information3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 1) What is a transformer and how does it work? A transformer
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationInstructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors
I.L. 17405 Revision F Instructions for Class W200, W201, Sizes 5 and 6, Three Phase Non-Reversing Magnetic Motor Starters and Contactors RATINGS The maximum horsepower ratings of these motor controllers
More informationSUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
More informationRelays and Timers Specifications Bulletin Number 700
Technical Data Relays and Timers Specifications Bulletin Number 700 Topic Page General Purpose Relays 2 Timing Relays 41 NEMA Industrial Relays 81 IEC Control Relays 93 Solid State Relays 109 Additional
More informationDimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
More informationProduct Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
More informationD7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC
April 00 D Series Standard and Full Featured - Catalogue Number Structure Table -. D Series Catalogue Numbering System Family Type DPR = Standard Relay DPF = Full Featured Relay Contact Configuration =
More informationSoftstarters Type PSR
Catalog Softstarters Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationBulletin 500 Line Open Type Modular Kits and Components. Selection Guide
Bulletin 00 Line Open Type Modular Kits and Components Selection Guide Bulletin 00, 00F, 0 AC Contactors and Starters Product Overview AC Contactor and Starter Modular Kits and Components sizes 0 for open-type
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationOwner's/Installation Manual
Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH
More informationBasic Nameplate Information
Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
More informationType Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1
Power PCB Relay G2R Creepage distance of 8.0 mm (0.31) min. between coil and contact. Dual-winding latching type available. Plug-in and quick-connect terminals available. High sensitivity (360 mw) and
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
More informationGeneral-purpose Relay
General-purpose Relay An Improved Miniature Power Relay with Many Models for Sequence Control and Power Applications A wide range of relay variations including ones with operation indicators, high-capacity
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationA product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS
A product made in Australia Insulated Conductor Rail ACTIV-8 PLUS ACTIV-8 PLUS The Industry Standard in Conductor Rails ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It
More informationMCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
More informationDecision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features
Decision-Maker Paralleling System Power Distribution Switchboards and Circuit Breakers Power Distribution Switchboards and Circuit Breakers The generator paralleling circuit breakers for the Kohler Decision-Maker
More informationFigure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.
Crydom RHP Series 3 Phase Hybrid Solid State Contactor By Paul Bachman Fellow Engineer, Crydom, Inc. ABSTRACT Solid State Relays and Contactors (SSRs) have been available in one form or the other for over
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationSafety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
More informationContactors Low Voltage
00Motor Starters and April 06 Sheet Motor Starters and ContactorsLow Voltage.0- ContactorsLow Voltage Contents Motor Starters and ContactorsLow Voltage Manual Motor Control MS Starter with Hand/Auto......................................-
More informationHPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationSpecifications. Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT:
Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Switch Operators Type CS-1A are high-speed
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More information40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
More informationContactor and Starter Ratings
Contactor and Starter Ratings Contactors and motor starters are rated according to size and type of load they are designed to handle. The National Electrical Manufacturers Association (NEMA) and the International
More information1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
More informationTable of Contents. Review Answers...77 Final Exam...80
Table of Contents Introduction...2 Motor Control...4 Power Supplies...8 Design Standards... 12 Need for Circuit Protection... 13 Motor Control Centers...21 tiastar MCC Construction...32 tiastar Arc Resistant
More information