1 EXPERT IN SAFETY AND SECURITY TECHNOLOGY CONTENTS System CK Control Panel CK Control Panel CK Control Panel RP2000 Repeater Panel YT202 Addressable Smoke WT205 Addressable Heat FT203 Addressable Smoke & Heat SB206 Addressable Manual Call Point SG209 Addressable Sound Strobe PM900 Address Programmer CM201 Addressable Input Module CM202 Addressable Output Module CM203 Interface Module CM204 Loop Isolator Module System Product Range Guide Date:

2 CONVOYTECH SECURITY TECHNOLOGY Over the past twenty years, We have always been dedicated to serving the diverse needs of our customers. Although we started out as a tiny engineering and manufacturing company in China and have grown into a global player in the international safety market, ConvoyTech continues to work hard to earn your trust and retain your confidence in our product line. ConvoyTech manufactures thousands of uniquely made smoke, heat and gas detectors annually, fulfilling a special role or function for each of our customers. ConvoyTech can custom-design detectors specifically for your applications. From product design to final manufacturing, we offer one-stop shopping for your residential and commercial detector needs. Any one of our existing product designs can also be modified to meet your specific requirements. In a "one-size-fits-all" world, ConvoyTech works harder to tailor our solutions to meet your needs. ConvoyTech is an ISO 9001:2000 certified manufacturer with an extended network of manufacturing subcontractors and suppliers located nearby. Our company currently owns a number of testing facilities, such as a UL-standard fire testing lab, a UL test box, a dust test chamber, an EN-54 testing tunnel, a buzzer sound-level trial station and a fluorescent-light interference testing site as well as EMC test equipment. We are also planning to expand our manufacturing and testing facilities in China to ensure that our products and manufacturing practices continue to meet the highest standards. Smoke, heat, and gas detector manufacturing isn t an easy business to be in. Faced with the stiff competition from cheaply made, low-quality detectors, we remain committed to our customers with high quality products at the most reasonable prices. Our focus is to deliver meaningful value to clients that choose our brand over the competition through our commitment to quality. This year we are preparing to introduce our new line of advanced, feature-rich conventional and addressable detectors and panels at a competitive price. We invite you to get to know ConvoyTech better. Experience the very best in smoke detector technology. We are convinced that you will find ConvoyTech superior to any other detector company in China. You'll see it in our facilities, in our people, and in the products that ConvoyTech makes. It's our uncommon commitment to excellence and quality, and to the automation and productivity of our customers. Introduction Control Panel 2 Loop Fire Alarm Control Panel Model:CK Loop Fire Alarm Control Panel Model:CK The panel is an addressable fire detection and indication control panel designed to meet all the requirements of EN54. Certificate EN541-2/4 Modular type panel, 2 Loop Panel 198 addresses per loop 2000 Cause-and-Effect scan be programmed Color Graphics LCD 320X240 displaying fire fault and messages Up to 64 panels or repeaters in one network, also used for software monitoring function USB Port for programming and firmware upgrade Event Log Memory 4 Programmable Relay output, 4 Programmable sound outputs Supports CST protocol The panel is an addressable fire detection and indication control panel designed to meet all the requirements of EN54. Certificate EN541-2/4 Modular type panel, 4 Loop Panel 198 addresses per loop 2000 Cause-and-Effect scan be programmed Color Graphics LCD 320X240 displaying fire fault and messages Up to 64 panels or repeaters in one network, also used for software monitoring function USB Port for programming and firmware upgrade Event Log Memory 4 Programmable Relay output, 4 Programmable sound outputs Supports CST protocol

3 Control Panel 6 Loop Fire Alarm Control Panel Model:CK The panel is an addressable fire detection and indication control panel designed to meet all the requirements of EN54. Certificate EN541-2/4 Modular type panel, 6 Loop Panel 198 addresses per loop 2000 Cause-and-Effect scan be programmed Color Graphics LCD 320X240 displaying fire fault and messages Up to 64 panels or repeaters in one network, also used for software monitoring function USB Port for programming and firmware upgrade Event Log Memory 4 Programmable Relay output, 4 Programmable sound outputs Supports CST protocol s Addressable Photoelectric Smoke Model: YT202 This Intelligent Addressable Photo-Electric Smoke uses an intelligent optical sensing chamber. This detector is designed to provide open area protection and to be used with our CST Protocol panels. It has two LEDs on each detector to provide a local 360 viewing alarm indication. It flashes every five seconds, indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. The LEDs will be off when a trouble condition occurs, indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. This detector supports External Remote indication LED. Repeater Panel Model:RP2000 The repeater panel is connected to CK2000 series panel to repeat the event message on the system. One CK2000 series panel can connect Max. 63 repeater. The repeater is connected with panel by 2 wire DC24V power and 2 wire RS485 communication. Dimension: 230mmX115mmX50mm Power: DC24V Communication: RS485 Smoke Alarm Addressable Fixed & Rate-of-Rise Heat Model: WT205 Addressable Multi Photoelectric Smoke & Heat Model: FT This Intelligent Addressable Fixed & Rate-of-Rise Heat Sensor uses a thermal sensing element for detection This detector is designed to provide open area protection and to be used with our CST Protocol panels. It has two LEDs on each detector to provide a local 360 viewing alarm indication. It flashes every five seconds, indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. The LED s will be off when a trouble condition occurs, indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. This detector supports External Remote indication LED. This Intelligent Addressable Multi- uses an intelligent optical sensing chamber and a thermal sensor at the same time to detect smoke and heat. This detector is designed to provide open-area protection and to be used with our CST Protocol panels. It has two LEDs on each detector to provide a local 360 viewing alarm indication. It flashes every five seconds, indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. The LEDs will be off when a trouble condition occurs indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption. This detector supports External Remote indication LED.

4 Products Addressable Manual Call Point Model: SB206 The device is an intelligent Addressable Call-Point based upon our industry standard series housing and features easy to install, push-fit wiring terminals. Can be reset by key Red colour Fire proof materials CST Addressable Protocol Modern style Call-Point Products Addressable Input Module Model: CM201 The device is a single input module designed to interface in a variety of inputs such as door contacts, sprinkler flow/door switches and plant equipment to the CST Addressable system. Single Loop Address Loop Powered One Inputs for Monitoring of Volt Free Contacts This Input can be Configured to Monitor either Normally Open or Normally Closed contacts Addressable Sound Strobe Model: SG209 The device is an addressable loop powered addressable sounder innovatively designed to provide a range of tones and volumes with a maximum output of up to 85dB(A) (±2dB(A)) with low current consumption. Loop Powered Single Loop Address - addressed via the Hand Held Programmer Variable Sound Output 70 ~ 85dB(A) (±2dB(A)) output at 1 metre Weatherproof Kit available Addressable Output Module Model: CM202 The device is a single output module designed to provide one generalpurpose relay output; this output can be driven separately for control of such devices as dampers or for control of plant and equipment shutdown. Loop Powered Single Address One Relay Controlled by loop Relays Contact Rated at 30Vdc at 1 amp Address Programmer Model: PM900 Battery Powered Read and Write device address LED display Smoke Alarm Interface Module Model: CM The device is a conventional detector interface module designed to provide conventional detector to be connected to the addressable panel loop. One conventional interface module can connect 25 conventional detectors and share one address on the addressable panel.

5 9 10 Products Loop Isolator Module Model: CM204 CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE The device is a negative-switching Loop Isolator, which is fully compatible with CST intelligent addressable protocol. The module incorporates an amber LED to show when it is isolating a section of the loop, and when used under each addressable sensor. If a single short circuit was to occur on the loop, then no Sensors would be lost. The device does not use an address, and has the same wiring Detects short circuits on loop Status LED Allows connection of sensors from the HST Range Bayonet slot, low insertion force for detectors Quick connection via square cable clamps LOOP+ LOOP- Smoke Heat Interface module Smoke Smoke & Heat Smoke Manual Call Point Heat Max. 198 addressable devices in one loop Max. 25 conventional detectors LOOP+ LOOP- Smoke Sound Strobe Input Module Output Module Manual Call Point Max. 198 addressable devices in one loop Bell Signal input Max. 5 to 10 (1A@24VDC) Sounder & Bell in One Sound Output SOUND2 (Alarm Zone2) Auxiliary DC28V output RS485 communication bus DC24+ DC24- A B NO.1 Repeater DC24V LOOP16 LOOP2 LOOP1 HOT NEUTRAL GROUND Alarm Relay Output Fault Relay Output AC Power Input(90-270V) COM NC NO COM NC NO COM NC NO DC24+ DC24- A B Max. NO.32 Repeater

6 Projects of fire alarm and control system Xi'An Qujiang New Area Building TianYuan community area ChangAn Exhibition Hall Xi'An Hi-Tech high school XiYang International Airport China Fast Gear Factory Smoke Alarm Product EXPERT IN SAFETY AND SECURITY TECHNOLOGY Telephone: +86-(0) Fax: +86-(0)

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

DTW Works Master Specification Version 2006

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4

More information

conventional system operation

conventional system operation conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped

More information

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008 Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

Expansion Modules & Accessories

Expansion Modules & Accessories HONEYWELL SECURITY & CUSTOM ELECTRONICS Expansion Modules & Accessories Honeywell s wide range of expansion modules and accessories enable you to configure a system to meet any installation challenge and

More information

Fire Alarm Control Panel. Family. Operating Manual

Fire Alarm Control Panel. Family. Operating Manual Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...

More information

Fire Detection Product Range

Fire Detection Product Range Fire Detection Product Range World Leading Fire Detection Products from the NITTAN group Issue 1.0 Business Overview The Nittan Group has been at the forefront of the fire protection industry since 1954

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

Product Information Fire alarm panel 8000 C

Product Information Fire alarm panel 8000 C Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.

More information

GST301. (Single Protection Zone) Operation Manual

GST301. (Single Protection Zone) Operation Manual GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...

More information

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0

More information

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February 2013. FA-300 SERIES Fire Alarm Control Panel ABC DEF GHI JKL MNO PQR STU YZ WXY FA-300 Series LCD Fire Alarm Control Panel Advanced Life Safety Solutions System Normal 10:36AM WED 2003-10-01 SYSTEM RESET A.C. ON ALARM SUPV TRBL CPU FAIL SIGNAL SILENCE

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

Fire detection equipment

Fire detection equipment PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,

More information

Analogue addressable devices

Analogue addressable devices Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

Fire alarm system EBL512 G3

Fire alarm system EBL512 G3 Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Generation three G3. Internet: pesn.panasonic.se 2011-03-24 Page 1 of 6 The demands

More information

D287/D288/D292/D293A/D293E

D287/D288/D292/D293A/D293E D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization

More information

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT ALARM SYSTEMS Peace of Mind Agri-Alert is a complete alarm system for monitoring temperature, power, feed and watering systems, burglary,

More information

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment

More information

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

Always on the Lookout Perfect Protection against Burglary

Always on the Lookout Perfect Protection against Burglary Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on

More information

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19 TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as

More information

GSM ATT Modules Simply effective remote control

GSM ATT Modules Simply effective remote control GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential

More information

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~ ID50 SYSTEM The Fire Alarm System can be activated in the following ways :~ 1. By breaking the glass in a Manual Alarm Call Point 2. By a rise in temperature activating an Automatic Heat Detector 3. By

More information

Module 5. Fire and Emergency Alarm System Part I- Basics

Module 5. Fire and Emergency Alarm System Part I- Basics Module 5 Fire and Emergency Alarm System Part I- Basics 1 This module will describe: 1. Components and the arrangements of components in fire and emergency alarm systems. 2. How these systems work. 3.

More information

AlarmSense 2-wire detection and alarm system. Product Guide

AlarmSense 2-wire detection and alarm system. Product Guide AlarmSense 2-wire detection and alarm system Product Guide Contents What is AlarmSense? 2 The purpose of AlarmSense 4 How AlarmSense works 4 Alarmsense Features 5 Detector removal monitoring 5 Priority/non-priority

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S7010 7165-1477:111

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S7010 7165-1477:111 NETWORK FIRE ALARM CONTROL PANEL FX-2003-12NDS Description Mircom s FleX-Net Series is a powerful intelligent networkable fire alarm solution designed with many levels of flexibility to meet virtually

More information

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.

More information

Global System Technology(UK) PLC The Intelligent Solution

Global System Technology(UK) PLC The Intelligent Solution Global System Technology(UK) PLC The Intelligent Solution MANUFACTURED IN ACCORDANCE WITH Intelligent Photoelectric Smoke Detector Aesthetically pleasing Low profile design 8 Bit intelligent processor

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat

More information

MINERVA MX MX Virtual Multi-Sensor Detectors

MINERVA MX MX Virtual Multi-Sensor Detectors DATASHEET MINERVA MX MX Virtual Multi-Sensor Detectors Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Optional bi-directional

More information

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors D7050/D7050TH EN Installation Instructions Multiplex Photoelectric Smoke Detectors D7050/D7050TH Installation Instructions.0 Description Notices These instructions cover the installation of the D7050/D7050TH

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

SECTION 16853 ZONED (DC LOOP) FIREALARM SYSTEM

SECTION 16853 ZONED (DC LOOP) FIREALARM SYSTEM SECTION 16853 ZONED (DC LOOP) FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1

More information

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM-10-011

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM-10-011 Fire Alarm System plan(s) MUST be reviewed and approved by the Belmont Fire Department prior to the start of construction. The design and any changes must be fully compliant with NFPA 1, NFPA 101, NFPA

More information

Overview of Fire Alarm Systems and Maintenance

Overview of Fire Alarm Systems and Maintenance Overview of Fire Alarm Systems and Maintenance By Mr. David Goh Vice President Fire Safety Managers Association Convener of Working Group for CP 10 : 2005 Er. Matthew Kwek Committee Member Fire Safety

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

Add Door Phones to Your Phone System

Add Door Phones to Your Phone System Universal Door Phone System Material Code/Comcode # 408466563 (controller) and # 408466548 (speaker) PEC # 5324-001 Add Door Phones to Your Phone System The Door Entry Controller system dramatically expands

More information

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM KNOXVILLE, TENNESSEE SECTION 28 31 11 PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 28 31 11 A. Extent of fire alarm and detection system work shall be as described in this specification, as

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT

More information

Commander 2000 Control Panel

Commander 2000 Control Panel Commander 2000 Control Panel Interactive Technologies, Inc. File: Panels Overview Applications Features The Commander 2000 is an affordable wireless security system that is easy to install and easy to

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM SECTION 16721 FIRE ALARM AND DETECTION SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

Fire & Security DETECTORS

Fire & Security DETECTORS Fire & Security DETECTORS Smoke Sensitivity 0.98 ~.0%/ft Obscuration Ceiling Spacing 50 foot rating for heat sensor Temperature Range 10ºC to 50ºC Humidity 0 to 95% RH, no condensation or icing Dimensions

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM 1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

SFC-200 SERIES LCD FIRE ALARM PANEL

SFC-200 SERIES LCD FIRE ALARM PANEL SFC-200 SERIES LCD FIRE ALARM PANEL User Guide LT-954SUM SFC-200 Series LCD Version User Guide Contents Introduction... 1 About this Manual... 1 Technical Support... 1 Main Display... 1 The Buzzer and

More information

3468-00 Lighting and Fire Alarm Training System Add-On

3468-00 Lighting and Fire Alarm Training System Add-On 3468-00 Lighting and Fire Alarm Training System Add-On LabVolt Series Datasheet Festo Didactic en 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 2 Additional Equipment

More information

APR-PRT3 Printer Module: C-Bus Programming Instructions

APR-PRT3 Printer Module: C-Bus Programming Instructions APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us

More information

GSM Voice Auto Dialer & SMS Sender JC-999

GSM Voice Auto Dialer & SMS Sender JC-999 GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C

More information

9448 Installation and User Guide

9448 Installation and User Guide 9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6 9448 INTRODUCTION The 9448 is a 3 zone control panel with separate Entry/Exit and

More information

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

500r+ Installation and User Guide

500r+ Installation and User Guide 500r+ Installation and User Guide Compatible Equipment 502rUK-50 Watch/Pendant PA. 509rUK-50 Smoke Detector 515rUK-00 10 metre passive infra red movement detector. 525rUK-00 Remote Set/Unset (Full and

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

Premier M Plus & Infinity 8

Premier M Plus & Infinity 8 25 Years of Manufacturing Excellence Premier M Plus & Infinity 8 Conventional Fire Alarm Systems 007 Assessed to ISO 9001: 2008 Certificate number 330 Premier M Plus 8-24 Zone Conventional Fire Alarm Panel

More information

Voice alarm system E100 the new standard for safe evacuation

Voice alarm system E100 the new standard for safe evacuation Voice alarm system E100 the new standard for safe evacuation Clear announcements and future-proof protection in case of fire Answers for infrastructure. E100 from Siemens so everyone knows what to do when

More information

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

SECURIT 800L+ CONTROL PANEL

SECURIT 800L+ CONTROL PANEL USER MANUAL SECURIT 800L+ CONTROL PANEL COMPANY PROFILE IntelliSense have been successfully making security products for over 20 years and lead the security industry throughout the world with many innovative

More information

SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION A. This section of the specifications includes the furnishing, installation, and connection of the microprocessor-controlled

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

The supplier and installer of the system should be approved by the local civil defence authority.

The supplier and installer of the system should be approved by the local civil defence authority. ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer

More information

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications Gen4 Intruder Alarm Panels SIMPLY SECURE For Residential & Small Commercial Applications Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Fire. The Fire Installers Mate. A guide to fire alarm systems design Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects

More information

SCORPION. micron security products

SCORPION. micron security products SCORPION 4120 6020 & 8020 USER INSTRUCTIONS Thank you for purchasing a Quality Micron Security Alarm Controller. Micron product is manufactured to exacting quality standards. We understand the importance

More information

SECTION 16610 FIRE DETECTION AND ALARM SYSTEM

SECTION 16610 FIRE DETECTION AND ALARM SYSTEM SECTION 16610 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 REQUIREMENTS A. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements, apply

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk

More information

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES 4-Wire Air Duct Smoke Detector Models DH-60 F-70.05 FEATURES Approvals/Listing UL 268A Listed File S1064 Factory Mutual Approved CSFM Listed #3240-1076:121 NYC MEA Listed #134-95-E City of Los Angeles

More information

ACTIVE 5 ENGINEERING MANUAL

ACTIVE 5 ENGINEERING MANUAL ACTIVE 5 ENGINEERING MANUAL C & K Systems Ltd C031-066 Issue 3 THE ACTIVE 5 INSTALLATION MANUAL. Date: Feb 1997 INTRODUCTION. The Active 5 is a microprocessor controlled intruder alarm panel. It features

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

ACP10 10 Zone Intruder Alarm System

ACP10 10 Zone Intruder Alarm System ACP10 10 Zone Intruder Alarm System Installation Manual Contents 1. System Overview... 4 System Configuration... 4 Control Panel... 4 Remote Keypads... 5 LED Remote Keypad... 5 LCD Remote Keypad... 5 USB-Link...

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum

More information

VISTA Commercial Solutions INFORMATION FOR DEALERS: COMMERCIAL CONTROLS FOR FIRE AND BURGLARY APPLICATIONS. Power, Versatility and Innovation.

VISTA Commercial Solutions INFORMATION FOR DEALERS: COMMERCIAL CONTROLS FOR FIRE AND BURGLARY APPLICATIONS. Power, Versatility and Innovation. VISTA Commercial Solutions INFORMATION FOR DEALERS: COMMERCIAL CONTROLS FOR FIRE AND BURGLARY APPLICATIONS Power, Versatility and Innovation. Turbocharge Your Commercial Installations Honeywell VISTA commercial

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

Potter Plus. Fire Alarm Control Panels

Potter Plus. Fire Alarm Control Panels Potter Plus Fire Alarm Control Panels Potter Fire: We stand apart. When it comes to fire protection companies, Potter stands apart. Apart from the competition and apart from the constraints of a large

More information