Rad-8. Signal Extraction Pulse Oximeter. Service Manual

Size: px
Start display at page:

Download "Rad-8. Signal Extraction Pulse Oximeter. Service Manual"

Transcription

1 Rad-8 Signal Extraction Pulse Oximeter Service Manual

2 Rad-8 Signal Extraction Pulse Oximeter Service Manual

3

4 The Rad-8 Service Manual is intended to provide the necessary information for proper servicing of the Rad-8 pulse oximetry system. This manual is structured to support troubleshooting to the assembly or module level. This manual does not provide instructions for troubleshooting to the printed circuit board component level. There may be information provided in this manual that is not relevant for your system. Do not service the Rad-8 pulse oximeter without completely reading and understanding these instructions. Fuse Rating (Qty 3): 1A, 250V (Approvals: UL , CSA C22.2 no Compliance: RoHS). Other specifications for Performance, Accuracy, Electrical and Environmental can be found in Section 7 of the Rad-8 Operator s Manual. CAUTION: Federal law (U.S.) restricts this device to sale by or on the order of a physician Masimo Corporation 40 Parker Irvine, CA USA Tel: Fax: Authorized Representative: MDSS GmbH Burckhardstrasse 1 D Hanover Germany Tel: Fax: Made in USA Masimo Corporation. All rights reserved. Masimo, Masimo Logo, SET, LNOP, LNCS, Radical, Rad-5, Rad-5v, Rad-57, Rad-8, Rad-9, SIQ, FastSat, FastStart Signal IQ and APOD are trademarks of Masimo Corporation. Covered by one or more of the following U.S. Patents: RE38,492, RE38,476, 6,699,194, 6,684,090, 6,658,276, 6,654,624, 6,650,917, 6,643,530, 6,606,511, 6,584,336, 6,501,975, 6,463,311, 6,430,525, 6,360,114, 6,263,222, 6,236,872, 6,229,856, 6,206,830, 6,157,850, 6,067,462, 6,011,986, 6,002,952, 5,919,134, 5,823,950, 5,769,785, 5,758,644, 5,685,299, 5,632,272, 5,490,505, 5,482,036, international equivalents, or one or more of the patents referenced at Other patents pending. i

5 Table of Contents Page 1. Overview About this Manual Warnings, Cautions and Notes Maintenance Introduction Cleaning Battery Operation and Maintenance Overview Replacing the Battery Performance verification Power-On Self-Test Key Press Button Test Alarm Limit Test LED Brightness... Erreur! Signet non défini Testing the Rad-8 with Masimo SET Tester (Optional) Repair Safety Precautions: General Procedures Troubleshooting Service Messages: Repair Policy Return Procedure Drawings and Schematics ii

6 1. Overview 1.1. About this Manual This manual explains how to service the Rad-8 class of pulse oximeters. However, when a differentiation between models is required, the actual model type will be identified prior to the explanation (For example, the difference between a Rad-8H (Horizontal) or Rad-8V (Vertical). Important safety information relating to general use of the Rad-8 class of pulse oximeters appears in the Rad-8 Operator s Manual. Other important safety information is located throughout this manual where appropriate Warnings, Cautions and Notes Please read and follow any warnings, cautions and notes presented throughout this manual. An explanation of these labels is as follows: A warning is provided when actions may result in a serious outcome (i.e., injury, serious adverse affect, death) to the patient or user. Look for text in a gray shaded box. Sample of Warning: WARNING: THIS IS A SAMPLE OF A WARNING STATEMENT. A caution is given when any special care is to be exercised by the patient or user to avoid injury to the patient, damage to this device or damage to other property. Sample of Caution: CAUTION: This is a sample of a Caution statement. A note is provided when extra general information is applicable. Sample of Note: Note: This is a sample of a Note statement. 1-1 Rad-5 Signal Extraction Pulse Oximeter Service Manual

7 2. Maintenance 2.1. Introduction This chapter covers, how to test the operation of the Rad-8 oximeters, how to properly clean, how to replace the battery and how to obtain service under normal operation. No internal adjustment or recalibration is required. Service should be done by qualified personnel only. Safety checks should be performed at regular intervals or in accordance with local and governmental regulations. WARNING: BEFORE CLEANING THE OXIMETER, TURN THE UNIT OFF Cleaning To clean the display panel, use a cotton swab moistened with 70% isopropyl alcohol and gently wipe the panel To clean the outer surface of the oximeter, the following solutions may be used to wipe the instrument for 30 seconds. Do not allow liquids to enter the interior of the instrument. Glutaraldehyde Solution Ammonium Chloride Wipe 10% Chlorine bleach in H2O 70% Isopropyl alcohol CAUTION: Do not autoclave, pressure sterilize, or gas sterilize this oximeter. Do not spray, soak, or immerse the monitor in any liquid. Use the cleaning solution sparingly. Allow unit to air dry. Excessive solution can flow into the monitor and cause damage to internal components. Do not touch, press, or rub the display panels with abrasive cleaning compounds, instruments, brushes, rough-surface materials, or bring them into contact with anything that could scratch the panel. Do not use petroleum-based or acetone solutions, or other harsh solvents, to clean the oximeter. These substances attack the device s materials and device failure can result. Rad-5 Signal Extraction Pulse Oximeter Service Manual 2-1

8 3. Battery Operation and Maintenance 3.1. Overview The Rad-8 oximeter uses a 6 volt, 1.4AHr lead acid, sealed, rechargeable battery Please reference the Rad-8 Operator s Manual for specifications on battery charge time and capacity Replacing the Batteries Turn the Rad-8 oximeter off and remove the patient cable connection Place the unit on its side with the rubber footings facing up Remove the four screws from the housing assembly Carefully remove the speaker-side housing assembly. DO NOT pull housing away as it may damage the speaker cable Remove the speaker connector from the system board and set the housing aside Carefully lift the battery out of the housing and remove the positive and negative battery connections Install the replacement battery. Verify proper positioning of the (+) positive and (-) negative connectors. Reverse steps through to reassemble Verify the unit turns on, that all the LEDs momentarily light (AC LED will not illuminate when powering on with battery power only), that the low battery LED is not illuminated, and that the unit stabilizes to a normal operation mode. CAUTION: Follow local governing guidelines for proper disposal of internal batteries. Do not incinerate. 3-1

9 4. Performance verification To test the performance of the Rad-8 pulse oximeter following repairs or during routine maintenance, follow the procedure outlined in this section. If the Rad-8 fails any of the described tests, discontinue its use and correct the problem before returning the unit back to the user Power-On Self-Test With Rad-8 plugged into an AC power source and no cable or sensor plugged into the instrument, turn the monitor on by depressing the Power Button. For about 2 seconds all available LEDs are illuminated and a brief beep tone sounds. The unit will then cycle through Saturation and Pulse alarm limits After this initialization boot cycle, the No Sensor, Alarm Suspend and Normal Sensitivity Mode LED indicator s will light. Also, the %SpO2 and BPM monitoring display will indicate NO SEN. The oximeter is ready to begin normal operation Turn power off and then back on as many times as necessary to verify this Power-On cycle Key Press Button Test With the exception of the Power Button, press each button and verify that the oximeter acknowledges each key-press with an audible beep tone or by indicating a change on the display Serial Port Test Using an IBM compatible computer, connect a straight through serial cable from the serial connection on your computer to the serial port on the rear of the Rad Initiate Hyper Terminal on your computer Setup Hyper Terminal using COM 1, then set Bits Per Second to 9600, data bits 8, Parity NONE, Stop Bits 1, Flow Control NONE From Setup Menu level 5 on the Rad-8, press the NEXT button for Serial Out and use the up/down arrows to select AS1(ASCII 1). Press Mode/Enter to start ASCII output Connect either a Masimo Tester or cable and sensor and verify output of Date, Time, SPO2%, BPM, PI, ALARM and EXC. 4-2

10 4.4. Sensor Test Insert a known good Oximeter Tester into the sensor connector Turn power on Wait approximately 10 sec for the SpO2 and Pulse Rate displays to produce a number. During that time, the display should show SEN OFF and then dashes Read the SpO2 value from the display, and verify it is within the specified limits(%spo2: 78 <= 84; BPM 60 <= 62) Alarm Suspend Indicator Induce an alarm condition Press the Alarm Suspend button and cycle through the 2 different indicator levels: yellow LED is Blinking or Off Alarm Volume Test Press the Mode/Enter button. Monitor displays should show AL and VOL Press the UP arrow button and cycle through the three different volume levels. Make sure the tone does not have a harsh or raspy tone due to the speaker rattling in the plastic housing. The tone heard should be louder with each press. Press the DOWN arrow button and cycle through the different volume levels. The tone heard should be quieter with each press. Verify both speakers are working Return the volume to the factory default level Button Volume Test Press the Mode / Enter button 2 times. LED displays should show 888 and Press the Next arrow key. LED displays should show but and VOL Press the UP arrow button and cycle through the different volume levels. Make sure the tone does not have a harsh or raspy tone due to the speaker rattling in the plastic housing. The tone heard should be louder with each press. Press the DOWN arrow button and cycle through the different volume levels. The tone heard should be quieter with each press. There are three volume levels and volume off Return the volume to the factory default level

11 4.8. Brightness Test Press the Mode / Enter button 2 times. LED displays should show 888 above and 888 below Press the Down arrow button and cycle down through the different brightness levels. Press the Up arrow button and cycle up through the different brightness levels. There are four brightness levels Press the Mode / Enter button 4 times to return to patient monitoring mode or wait for display to time out Trauma Mode Test Press the Trauma button. The Max sensitivity and FastSat LEDs should light Press the Trauma button again and the Max and FastSat LEDs should extinguish Sensitivity Mode Press the Sensitivity button to alternately light the APOD, NORM, and MAX LEDs Fast Sat Mode test Press the FastSat button. The FastSat LED should light Press the FastSat button again and the FastSat LED should extinguish. Note: Selecting the FastSat averaging button will not automatically set the sensitivity mode to Max sensitivity Alarm Limit Test With the monitor turned on, depress the ALARM LIMITS button and enter alarm menu. Change the High Saturation Alarm parameter to a value two points below the currently selected value, and accept the change by pressing the Mode/Enter button Verify that the newly set parameter is shown on the Saturation Alarm Limit Display Return the High Saturation Alarm parameter to its original setting and accept the change by pressing the Mode/Enter button Repeat steps to with the Low Saturation Alarm parameter. 4-4

12 Repeat steps to with the Low and High Pulse Rate Alarm parameter Reset the alarm limits again to the original settings and accept the changes by pressing the Mode/Enter button Date and Time Setting Press the Mode / Enter button 4 times and verify that Set CL message appears on the display Press the Next arrow key and Yr XX will be displayed Verify that correct year is displayed Use Up / Down arrow buttons to set accordingly Press the Next arrow key and nn XX will be displayed Verify that correct month is displayed Use Up / Down arrow buttons to set accordingly Press the Next arrow key and day XX will be displayed Verify that correct day is displayed Use Up / Down arrow buttons to set accordingly Press the Next arrow key and Hr XX will be displayed Verify that correct hour is displayed Use Up / Down arrow buttons to set accordingly Press the Next arrow key and nn XX will be displayed Verify that correct minute is displayed Use Up / Down arrow buttons to set accordingly Press the Mode / Enter button Cycle power and verify the settings Turn power off. 4-5

13 5. Repair 5.1. Safety Precautions: WARNING: When removing or installing any internal electrical components, be sure to first disconnect at least one terminal of the battery. Verify reconnection of battery prior to reassembly of unit for patient monitoring. WARNING: ENSURE THE UNIT HAS BEEN CLEANED PER THE CLEANING INSTRUCTIONS IN SECTION General Procedures Inspect the unit for cosmetic damage prior to disassembly or troubleshooting. External damage may be helpful in determining the root cause of the failure Note any markings or labeling on the unit that may have been placed by the end user. Duplicate or transfer this information in the event the housing or ancillary components are replaced Make note of the unit s serial number Make note of the software versions in the event the Oximeter board or system boards are replaced. These boards require software updates to make them compatible with the end user s version of software Contact Masimo Corporation using the information in Section to research warranty history Troubleshooting The troubleshooting procedures in this manual instruct the technician to isolate the failure down to the sub-assembly level. The intention is to have the Unit Under Test (UUT) repaired with minimal steps. The Masimo SET Tester is needed to perform the Performance Verification in Section 4 upon completion of repairs. Note: The Masimo SET Tester is not a calibrated device. It is to be used for evaluation purposes only and not to determine if an oximeter is calibrated Tools required are as follows: Phillips head screwdriver #1 Multimeter 5-6

14 The troubleshooting steps below are presented in order of the most probable cause first. Proceed to the next step only if the unit continues to fail. Symptom Speaker Alarming (very loud) and unit is not functioning or displaying. Alarm LED does not Illuminate 1. Unit must be in alarm state. 2. Audible alarm can be heard. Alarm Condition But No Audible Indication. 1. Unit is in alarm condition. Display Missing Segments Button Function Error 1. Any front panel button Affected. 2. Buttons do not activate feature. "No Sen", or Sen Off Displayed. 1. Cable is connected with sensor attached. Unit Will Not Turn Off Cause and Corrective Action Steps Probable Watchdog error. 1. Replace System board. 2. Replace User Interface board. 1. Replace User Interface board. 2. Replace Display board. 1. Replace Speaker. 2. Replace System board. 1. Replace User Interface board. 2. Replace Display board. 1. Replace Keypad. 2. Replace User Interface board. 1. Replace sensor. 2. Replace patient cable. 3. Replace flex cable. 4. Replace oximeter board. 1. Replace Keypad. 2. Replace System board. If unable to repair unit, then please call (800) option #2 to arrange for return to Masimo Corporation. 5-7

15 5.4. Service Messages: Upon detection of a system error, the main software alerts the user with an audible alarm indicator and displays the appropriate error code on the display. The MS board is held in reset and no other runtime functionality is available to the user until the unit is power cycled or until power is completely removed and re-applied to the system (removal and/or replacement of battery). System Error System Error Code MS board communication Failure 1 MS board Diagnostics Failure 2 User Interface Waveform Overwrite 3 Sound Processor Waveform Overwrite 4 Main Processor Waveform Overwrite 5 Sat Pulse Rate Update Failure User Interface 6 Sat Pulse Rate Update Failure Sound Processor 7 User Interface One Time Command Overwrite 8 Sound Processor One Time Command Overwrite 9 Main Processor One Time Command Overwrite 10 Vor Voltage Error 11 Vbatt Voltage Error 12 V5 Voltage Error 13 Vcc Voltage Error 14 User Interface Revision Table Mismatch 15 Sound Processor Revision Table Mismatch

16 5.5. Repair Policy Masimo or an authorized Service Department must perform warranty repair and service. Do not use malfunctioning equipment. The product must be repaired Please clean contaminated/dirty equipment before returning. Make sure it is fully dry before packing the equipment To return the unit for service, please follow the Return Procedure outlined in this section Return Procedure Please clean contaminated/dirty equipment before returning and make sure it is completely dry before packing the equipment Recommended decontamination procedure for equipment that has the potential for being exposed to blood or other potentially infectious materials Put on Lab coat or other protective garment Put on gloves Place equipment on the designated decontamination table Apply cleaning agent (10% bleach to water solution) to paper towel or use Cidex wipes Wipe down all aspects of the equipment Let the equipment air dry completely Remove gloves Move equipment to the area designated for equipment that has been through the decontamination process Dispose of all contaminated products properly Package the equipment securely in the original shipping container if possible and enclose the following information and items: Call Masimo domestically at (800) , option #2, internationally at , option #2 and ask for an RMA number. 5-9

17 A letter or describing in detail any symptoms or difficulties experienced with the pulse oximeter. Please include the RMA number in the letter Warranty information a copy of the invoice or other applicable documentation must be included Purchase order number to cover repair if the oximeter is not under warranty, or for tracking purposes if the warranty is in effect Ship-to and bill-to information Person (name, telephone/telex/fax number, and country) to contact for any questions about the repairs A document stating the oximeter has been decontaminated for bloodborne pathogens Return pulse oximeter to the following shipping address: Masimo Corporation 40 Parker Irvine, California USA (Domestic Toll Free): , option #2 (International): , option #2 FAX:

18 6. Drawings and Schematics 6-3

19 6-4

20 6-5

TECHNICAL SERVICE BULLETIN

TECHNICAL SERVICE BULLETIN Product Name: Masimo Rad-8 Symptom: Inability to retain user default settings on Rad-8 device after power cycle Cause: The Rad-8 device has been noted to revert back to factory default settings after power

More information

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM Inform II BLOOD GLUCOSE MONITORING SYSTEM Quick Reference Guide for Healthcare Professionals 2 Table of Contents Important... 4 General Information... 6 ACCU-CHEK Inform II Meter...10 How to Perform Patient

More information

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS + Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: 1-800-447-IABP (4227)

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: 1-800-447-IABP (4227) FiberOptix TM AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE U.S. and Canada: 1-800-447-IABP (4227) Worldwide: 617-389-8628 Caution: U.S. Federal Law limits this device

More information

Back-UPS Pro 1300/1500 Installation and Operation

Back-UPS Pro 1300/1500 Installation and Operation Back-UPS Pro 1300/1500 Installation and Operation Inventory Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Connect the battery bu059a bu058a

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens replace the projection lamp replace the batteries in the remote use the security lock feature troubleshoot the projector Cleaning

More information

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply Unit (Upu) BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens clean the fan intake filter replace the projection lamp replace the batteries in the remote control use the Kensington lock feature

More information

COASTAL AMUSEMENTS INC.

COASTAL AMUSEMENTS INC. TUTTI FRUITTI A skill based video game OPERATOR MANUAL VERSION TUTTI.D.1.0.1 COASTAL AMUSEMENTS INC. 1950 Swarthmore Ave, Lakewood NJ 08701 Tel. (732) 905-6662 Fax (732) 905-6815 http://www.coastalamusements.com

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures

More information

PA500II Enterprise Mobile Computer

PA500II Enterprise Mobile Computer PA500II Enterprise Mobile Computer - PA500II - Quick Reference Guide 400891G Version 1.0 PA500II Product Introduction & Accessory Kit After opening the box, ensure the following accessories for the PA500II

More information

Installation and Operation Back-UPS 1250, 1300, 1500

Installation and Operation Back-UPS 1250, 1300, 1500 Installation and Operation Back-UPS 1250, 1300, 1500 Inventory bu001a Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with

More information

Remote Alarm Monitoring System

Remote Alarm Monitoring System Remote Alarm Monitoring System Operation and Service Manual Model RA1 RA4 A A Version HELMER SCIENTIFIC 14400 Bergen Boulevard Noblesville, IN 46060 USA PH +1.317.773.9073 FAX +1.317.773.9082 USA and Canada

More information

http://www.coastalamusements.com

http://www.coastalamusements.com Nexus is a Registered Trademark of Coastal Amusements. OWNERS MANUAL 1935 Swarthmore Avenue, Lakewood, NJ 08701 (732)-905-6662 FAX (732)-905-6815 http://www.coastalamusements.com GAME DESCRIPTION Nexus

More information

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure CAS MEDICAL SYSTEMS, INC. 510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure using the 2301Multi-Function Tester 44 East Industrial Road Branford, CT 06405 USA www.techsrv@casmed.com

More information

XP Series Balances Operation Manual

XP Series Balances Operation Manual XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business

More information

MultiDim MKII V.2 ORDERCODE 50386

MultiDim MKII V.2 ORDERCODE 50386 MultiDim MKII V.2 ORDERCODE 50386 Congratulations! You have bought a great, innovative product from Showtec. The Showtec MultiDim brings excitement to any venue. Whether you want simple plug-&-play action

More information

Cable Tester Pro ORDERCODE D1909

Cable Tester Pro ORDERCODE D1909 Cable Tester Pro ORDERCODE D1909 Congratulations! You have bought a great, innovative product from DAP Audio. You can rely on DAP Audio, for more excellent audio products. We design and manufacture professional

More information

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada 1-888-845-7330

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada 1-888-845-7330 All about the Use & Care of your Iron Important Safeguards... 2 Iron Safety Instructions... 3 Parts and Features...4 TA B L E O F C O N T E N T S Using Your Iron...6 Cleaning and Maintenance... 8 Warranty...9

More information

How To Install A Power Supply (Uplast) With A Battery Pack

How To Install A Power Supply (Uplast) With A Battery Pack APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects

More information

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions THE NEW GENERATION IN TECHNOLOGY NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking Operating Instructions Table of Contents Important Safeguards... 3 Parts... 6 Controls... 6 To Set Up... 7 ipod/iphone

More information

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Back-UPS 650 VA 120 V with AVR (BX650CI-LM) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit

More information

Single Day Alarm Clock with. Bluetooth and USB Play-through

Single Day Alarm Clock with. Bluetooth and USB Play-through Single Day Alarm Clock with Bluetooth and USB Play-through MODEL : BSC 200 READ THIS INSTRUCTION MANUAL BEFORE OPERATING THE APPLIANCE. SAVE THIS MANUAL FOR FUTURE REFERENCE. TABLE OF CONTENTS IMPORTANT

More information

D I G I T A L C L A M

D I G I T A L C L A M T h e M A X X P r e s s D I G I T A L C L A M O P E R A T O R S M A N U A L 6 x0 x5 5 x5 Folie & Papper Sweden AB Box 90 00 9 Göteborg Telefon 03-9 00 80 Fax 03-9 00 89 www.foliepapper.se Safety Instructions

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

CINEMATE 1 SR DIGITAL HOME THEATER SPEAKER SYSTEM. Operating Guide Guía del usuario Guide d utilisation

CINEMATE 1 SR DIGITAL HOME THEATER SPEAKER SYSTEM. Operating Guide Guía del usuario Guide d utilisation CINEMATE 1 SR DIGITAL HOME THEATER SPEAKER SYSTEM Operating Guide Guía del usuario Guide d utilisation Notice This equipment has been tested and found to comply with the limits for a Class B digital device,

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage

More information

Instruction Manual FL

Instruction Manual FL 3. Operation Overview The most common used features (such as displaying force, peak hold, zero and changing of displayed units) can all be done by pressing a single dedicated key identified on the front

More information

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

BLOOD COLLECTION MIXER

BLOOD COLLECTION MIXER USER S MANUAL BLOOD COLLECTION MIXER Model CM735 No. CAT.CM73522Ce Centron Technologies Corporation 319-25 Sadang-4-dong, Dongjak-ku Seoul, Korea 156-823 Tel. +82-2.522.7807 Fax +82-2.522.7806 Table of

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Manual Ranging MultiMeter

Manual Ranging MultiMeter Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!

More information

CarePartner Telephone With Reminders

CarePartner Telephone With Reminders Philips wordmark and Lifeline K100 CarePartner Telephone With Reminders Model 9500 User s Manual Black and white version For use with newsprint and other one-color applications. 1 x P height 1 x P height

More information

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the

More information

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy. Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

Installation Instructions For Controllers with MS/TP Automatic MAC Addressing. Patent Pending 000-019-01

Installation Instructions For Controllers with MS/TP Automatic MAC Addressing. Patent Pending 000-019-01 Installation Instructions For Controllers with MS/TP Automatic MAC Addressing Patent Pending 000-019-01 KMC Controls Important notices Disclaimer 2009, KMC Controls, Inc. TotalControl, BACstage and FullBAC

More information

Electrical Stability Tester, Model 23E Instruction Manual Manual No. 102149576, Revision B Instrument No. 102130986

Electrical Stability Tester, Model 23E Instruction Manual Manual No. 102149576, Revision B Instrument No. 102130986 Electrical Stability Tester, Model 23E Instruction Manual Manual No. 102149576, Revision B Instrument No. 102130986 Fann Instrument Company Electrical Stability Tester Instruction Manual 2012 Fann Instrument

More information

Critical Care Therapy and Respiratory Care Section

Critical Care Therapy and Respiratory Care Section Critical Care Therapy and Respiratory Care Section Category: Clinical Section: Clinical Monitoring Title: Overnight Pulse Oximetry Policy #: 08 Revised: 03/00 1.0 DESCRIPTION 1.1 Definition 1.1.1 A pulse

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

OC-3 SERIES OF PRINTERS

OC-3 SERIES OF PRINTERS 110204-003 OC-3 SERIES OF PRINTERS User Guide TABLE OF CONTENTS OC-3 Printer Views... 1 Front and back view... 1 Side views... 1 Setting up your printer... 2 Unpacking your printer... 2 Installing/removing

More information

Congratulations! Thank you!

Congratulations! Thank you! TM-47 ORDERCODE D1370 Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio Microphone range brings excitement to any venue. Whether you want simple plug-&-play action

More information

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com

More information

MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W

MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the

More information

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series Operating Instructions WARNING CONCERNING THE REMOVAL OF COVER: CAUTION: TO PREVENT THE RISK OF ELECTRIC

More information

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:

More information

User s Manual AURORA 1.2K/2.2K

User s Manual AURORA 1.2K/2.2K User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable

More information

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual Contents 1) Operation 2)

More information

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018

USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018 USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and

More information

Model 349KLX Remote Display Digital Scale User Instructions

Model 349KLX Remote Display Digital Scale User Instructions Model 349KLX Remote Display Digital Scale User Instructions P/N UM349KLX Rev 3-080713 1 Model 349KLX Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully,

More information

PK5500 v1.1 Installation Instructions

PK5500 v1.1 Installation Instructions PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on

More information

PowlVac Vacuum Integrity Tester

PowlVac Vacuum Integrity Tester Instructions IB-60025B PowlVac Vacuum Integrity Tester POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900 FAX (713) 947-4453 www.powellelectric.com

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless

More information

TOYOTA TECHNICAL. An example of a tire pressure monitor valve sub-assembly. This mounts to a drop area in the wheel.

TOYOTA TECHNICAL. An example of a tire pressure monitor valve sub-assembly. This mounts to a drop area in the wheel. TOYOTA TIRE PRESSURE WARNING SYSTEM Toyota uses various tire pressure warning systems. Here, we ll discuss the system featured on the 2006 Land Cruiser. Combination meter warning reset switch warning reset

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

PR 50 Frymaster Universal Holding Cabinet (UHC)

PR 50 Frymaster Universal Holding Cabinet (UHC) PREP EQUIPMENT PR 50 Frymaster Universal Holding Cabinet (UHC) Models UHCP2, UHCP4, UHCPN4 Daily maintenance tasks PR 50 D1 Clean UHC Monthly maintenance tasks PR 50 M1 Calibrate UHC Annual maintenance

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear. SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between

More information

CS55H HOME EDITION... WIRELESS HEADSET SYSTEM

CS55H HOME EDITION... WIRELESS HEADSET SYSTEM CS55_HO_606.qxd /6/06 : PM Page ii WARRANTY Limited Warranty This warranty covers defects in materials and workmanship of products manufactured, sold or certified by Plantronics which were purchased and

More information

FT-100 Fire Training Fog Machine User Manual English

FT-100 Fire Training Fog Machine User Manual English FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual - English Safety Information Please read the following safety information carefully before operating

More information

Getting Started. rp5800, rp5700 and rp3000 Models

Getting Started. rp5800, rp5700 and rp3000 Models Getting Started rp5800, rp5700 and rp3000 Models Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows

More information

Back-Up Camera Installation Guide

Back-Up Camera Installation Guide Hz Hz In This Guide: Back-up camera installation requires connecting power wiring to the existing reverse lighting circuit and adding a chassis ground, as well as routing a video signal cable to the front

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk

More information

HP R12000 and R18000 DirectFlow UPS User Guide

HP R12000 and R18000 DirectFlow UPS User Guide HP R12000 and R18000 DirectFlow UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R12000 and R18000 DirectFlow UPS. This document is for the

More information

MAC Viper Quadray Module Installation and Control Guide

MAC Viper Quadray Module Installation and Control Guide MC Viper Quadray Module Installation and Control Guide Introduction This Guide explains how to install the Martin MC Viper Quadray Module, P/N 91614052, on a Martin MC Viper irfx fixture and control the

More information

Automatic Phone-Out Home Monitoring Systems

Automatic Phone-Out Home Monitoring Systems Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are

More information

Operating instructions Cordless K 10253 impact wrench

Operating instructions Cordless K 10253 impact wrench Operating instructions Cordless K 10253 impact wrench Operational precautions General safety instructions warning! 1. Consider work area environment. Do not expose tools to rain. Do not use tools in damp

More information

KUSTER ELECTRONIC GAUGES

KUSTER ELECTRONIC GAUGES Kuster Company 2900 E. 29th Street Long Beach, CA USA 90806 Telephone 562-595-0661 Fax 562-426-7897 E-Mail kuster@kusterco.com KUSTER ELECTRONIC GAUGES K8 EMR 25, K8 EMR 39, K4 EMR ¾, K4 EMR ¾ QUARTZ SERVICE

More information

Signal Manager Installation and Operation Manual

Signal Manager Installation and Operation Manual Signal Manager Installation and Operation Manual Rev.11/28/2008 Part # 26550007 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 CHAPTER 2: SYSTEM INSTALLATION... 4 HARDWARE

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

User Manual. Video Doorphone CDV-1020AQ

User Manual. Video Doorphone CDV-1020AQ User Manual Video Doorphone CDV-1020AQ 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

How To Set Up An Inverter

How To Set Up An Inverter MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS Installation Guide GSM Option Kit FLX series www.danfoss.com/solar Safety Safety Safety Message Types WARNING Safety information important for human safety.

More information

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply User Manual English APC Smart-UPS SC 1000/1500 VA 110/120/230 Vac 2U Tower/Rack-Mount Uninterruptible Power Supply 990-1851C, 10/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed

More information

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS GENUINE PARTS INSTALLATION INSTRUCTIONS 1. DESCRIPTION: Auto-Dimming Mirror Kit with Compass and HomeLink 2. APPLICATION: Titan 3. PART NUMBER: 999L1 WS000 4. KIT CONTENTS: Item Qty Description Service

More information

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION: Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury. Product Description The APC by Schneider Electric Smart-UPS is a high performance uninterruptible power supply (UPS). The UPS provides protection for electronic equipment from utility power blackouts,

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

Life Is Calling. Meet Your New CaptionCall Phone. Spoken Words into Captions. Free Service Means No Cost to You. 2 CaptionCall

Life Is Calling. Meet Your New CaptionCall Phone. Spoken Words into Captions. Free Service Means No Cost to You. 2 CaptionCall setup guide Life Is Calling Meet Your New CaptionCall Phone We d like to introduce you to CaptionCall. Your new CaptionCall phone looks and works pretty much like an ordinary telephone, but with one big

More information

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to

More information

Home Security Alarm System

Home Security Alarm System Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller

Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:

More information

Automatic Telephone Dialer TD-101(W)

Automatic Telephone Dialer TD-101(W) Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

PAR Tablet 10 Quick Start Guide

PAR Tablet 10 Quick Start Guide ParTech, Inc. 8383 Seneca Turnpike New Hartford, NY 13413 p.800.458.6898 www.partech.com PAR Tablet 10 Quick Start Guide PN 770505503 This material has been created in order to accommodate a wide range

More information

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7 Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual Internet Office & BC Personal UPS Systems Not suitable for mobile applications. Important

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Welch Allyn Vital Signs Monitor 300 Series

Welch Allyn Vital Signs Monitor 300 Series Welch Allyn Vital Signs Monitor 300 Series Upgrade Installation Guide Vital Signs Monitor 300 Series Service Utility Tool Version 2.0.0 ii Welch Allyn Vital Signs Monitor 300 Series Copyright 2007, Welch

More information

3 WATT LED SPOTLIGHT Model No. SLM - 3801

3 WATT LED SPOTLIGHT Model No. SLM - 3801 3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging

More information

Preface. Manual Revisions

Preface. Manual Revisions Preface D-Link reserves the right to revise this publication and to make changes in the content hereof without obligation to notify any person or organization of such revisions or changes. Manual Revisions

More information

EKOS Cart. Instructions for Use

EKOS Cart. Instructions for Use EKOS Cart Instructions for Use EKOS Corporation 11911 North Creek Parkway South Bothell, WA 98011 USA (425) 415-3100 (tel) (425) 415-3102 (fax) info@ekoscorp.com (e-mail) - 1-4913-002 REV E Intended Use

More information