1 SARGENT Wiring Instructions for Ecoflex Electrified Mortise Locks* (7970,7,7,73 & 870,7,7,73) for -4 Volts and Mechanical Mortise Locks with Monitoring Prefixes (RX, LX & DX) with the ElectroLynx Connector System For assistance, contact SARGENT at WIRE (9473) or w Important CAUTION: The voltage applied to the lock actuator must not exceed 0% of rated voltage. If the voltage exceeds this value, the actuator may be damaged. Specifications / Functions Ecoflex Actuator Fail Safe Models: 7970, 797, 870 and 87 (each /4 volts) /4 volts) RX-, LX-, and DX- Lock es AMP 4VDC RX- (lever monitor switches) LX- (latch monitor switch): *Patent Pending DX- (deadbolt monitor switch): Table of Contents Important/CAUTION Specifications/Functions Installation Notes Installing And Wiring Ecoflex Electrified Mortise Locks 7900 & 800 Series RX-7900 & RX-800 Series RX-LX-800 Series LX-800 Series Installing And Wiring Mechanical Mortise Locks With Monitoring RX-7900 & RX-800 Series RX-LX-800 Series RX-DX-800 Series LX-800 Series DX-800 Series Copyright 04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. A77D

2 two- IMPORTANT: to Actuator only LX / DX Actuator Fail Secure Check Polarity: Verify + (red) wire LX Fail Secure Fail Safe DX Fail Safe *Patent Pending Installation Notes. Install mortise lock and electric hinge. With new applications, a raceway harness will be pre-installed inside the door by ASSA ABLOY door manufacturer when specified during ordering process. kits are also available for retrofit applications.. If door does not have a raceway harness with, either consult factory for raceway retrofit kit or cut the off product and hardwire, as required. 3. Wiring to pigtail harness is per facility wiring requirement. Follow individual instructions below. ElectroLynx Connector System Notes The system is designed to be installation friendly with from the electric hinge through the door to the lock. The only wiring is to the harness which plugs into the electric hinge. IMPORTANT: The plug and receptacle are designed to mate and lock together as shown in the illustration. Plug the into each other with the locking mechanism aligned as indicated. Do NOT force on any other way. 8-Pin Connector Locking mechanism Look for the LYNX Plug Receptacle ElectroLynx As part of their promise to provide innovative, fast and effective, and higher security solutions to their customers, ASSA ABLOY Group companies offer ElectroLynx, a universal quick-connect system that simplifies the electrification of the door opening. ElectroLynx is a registered trademark of ASSA ABLOY, Inc. A77D Copyright 04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.

3 Ecoflex installation Red (+), Black (-), Pigtail harness ( wires with an 8-pin connector) Red (+), Black (-), Electrified mortise lock with 8-pin connector Plug together Black (-) Red (+) ( wires with an 8-pin connector) connector. 4-pin are not used here. A VDC.0 AMP Regulated and Filtered Power Supply Input L N 0VAC 60HZ 0VAC L/N/G GND Output Output 4VDC Normally Closed Fire Alarm Contact (If Required) C * or relay contacts NO NC Pigtail harness ( wires with 8-pin connector) Red (+), Black (-), * Note: Wire 7970/870 or 797/87 (Fail Safe) Locks to switch as shown. For 797/87 or 7973/873 (Fail Secure) Locks wire switch NO (normally open) contact to red wire of pigtail harness. Plug into 8-pin hinge connector at door (8 Volt) Fail Safe actuator with a 0/4VAC transformer LINE NORMALLY CLOSED FIRE ALARM CONTACT (IF REQUIRED) C NO NC Red (+), Black (-), ELECTROLYNX CONNECTORS Electromechanical Mortise Lock 0 VAC 4VAC Pigtail Harness wire with 8 pin connector Red (+) Black (-) NEUTRAL actuator Copyright 04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. A77D

4 Ecoflex RX- (7900 & 800 locks) The RX-switches are in the latch is extended. RX-switches monitor inside and Solenoid White (C), 3 Red (+), Black (-), Pigtail harness with 8-pin connector with 8 wires with 8-pin with 8 wires 8 wires Note: V Lock has Red Heat Shrink 4V Lock has Black Heat Shrink RX-7970, 7, 7 or 73 or RX-870, 7, 7 or 73 lock with 8-pin connector connector. 4-pin are not used here. Ecoflex RX- and LX- wiring (800 locks only) The RX-switches are in the latch is extended. RX- switches monitor inside and Solenoid White (C), 3 Red (+), Black (-), LX- switch monitors latchbolt movement Pigtail harnesses with 8&4-pin with 8 & 4-pin 8 wires LX- wiring (3 wires) RX-LX-870,7,7 or 73 lock with 8 & 4-pin LX - The LX- switch is in the the latch is extended., 4, 3, A77D Copyright 04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.

5 Actuator with LX- wiring (800 locks only) LX- switch monitors latchbolt retraction LX - Solenoid The LX-switch is in the the latch is extended Adaptor Harness (8 & 4-pin to 6 wires and 8-pin connector). Plug in between lock and raceway harness. Blue (NC), 6 Orange (NO), 5 Green (C), 4 Red (+), Black (-), with 8-pin connector Pigtail Harness with 8-pin connector Actuator wiring ( wires) Red (+) Black (-) LX- wiring (3 wires) connector. 4-pin are not used here. LX-870,7,7 or 73 lock with 8 & 4-pin RX- wiring (7900 & 800 locks) RX- switches monitor inside and RX- wiring (6 wires) 6 wires RX-7900 or RX-800 series lock with 8-pin connector White (C), 3 The RX-switches are in the latch is extended. with 8-pin Pigtail harness with 8-pin connector connector. 4-pin are not used here. Copyright 04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. A77D 5

6 RX- LX- wiring (800 locks only) RX- switches monitor inside and RX- wiring (6 wires) 6wires LX- wiring (3 wires) RX-LX-800 series lock with 8 & 4-pin LX- Pigtail harnesses with 8 & 4-pin LX - The RX-switches ar e in the, 4, 3, 4 3 The LX-switch is in the RX- DX- wiring (800 locks only) The RX-switches ar e in the RX- switches monitor inside and RX-wiring (6 wires) 6wires DX-wiring (3 wires) RX-DX-800 series lock with 8 & 4-pin DX- Pigtail harnesses with 8&4-pin DX- The DX-switch is in the, 4, 3, A77D Copyright 04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.

7 LX- wiring (800 only) LX- LX - LX DX- wiring (800 locks only) DX- DX - DX Copyright 04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. A77D 7

8

Transfer Device Solutions

Transfer Device Solutions McKINNEY QC hinge transfers power from the power supply to the exit device Electromechanical exit device with ElectroLynx 3" cable, minimum, needed between electromechanical exit and QC hinge Contents

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4 TABLE OF CONTENTS A Adjustable Angle Bracket (294/2942)... 6 Angle Brackets (2950 Series)... 9 Armature Mounting Plates (2950 Series)... 7 C Coordinator Mounting Bracket (2950 Series)... 7 Concealed Magnetic

More information

Shunt lock function 3066

Shunt lock function 3066 Version: January 2004 Contents Alarm System Activation unit Deactivation unit Digital locking cylinder or Smart Relay 1.0 Method of Operation 4 1.1 General 4 1.2 Turning the Alarm System On 4 1.3 Turning

More information

User Manual for CH-PFC76810

User Manual for CH-PFC76810 AA Portable Power Corp www.batteryspace.com, Email: Sales@batteryspace.com User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those

More information

ABLOY EL614 Motor lock with bolt Abloy Oy An ASSA ABLOY Group company EL614 42/52 25/35 25 22 263.5 225 38.2 17.3 3 10 2 Contents TECHNICAL DATA... 4 INSTALLATION... 5 WIRING DIAGRAM... 6 DRILLING SCHEME...

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE. LIGHT BLUE GRAY PURPLE Circuit Breaker Intput Circuit Breaker Output #1 Relay Left Hand Limit Switch Housing Left Hand Motor Connector Right Hand Limit Switch on Radiator Support Right Hand Limit Switch

More information

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables. Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor

More information

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means

More information

CMD-10k COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

CMD-10k COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM CMD-10k COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM INTRODUCTION Thank you for purchasing the CMD-10k Commander from Dakota Digital. This, along with many other products that Dakota Digital has to offer,

More information

7200 series Electromechanical Closer/Holder

7200 series Electromechanical Closer/Holder 7200 series Electromechanical Closer/Holder introduction The 7200 Series Electromechanical Closer/Holders combine the functions of an electromechanical door holder with the 7700 series door closer. The

More information

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code

More information

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM INTRODUCTION Thank you for purchasing the CMD-9000 Commander from Dakota Digital. This, along with many other products that Dakota Digital has to offer,

More information

Door control and security hardware

Door control and security hardware Door control and security hardware Introduction Since pioneering the first exit device in 908, Von Duprin life safety products have provided unparalleled quality, performance and flexibility for schools,

More information

ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions

ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions CONTENTS ABLOY LE180..3 ABLOY LE184..4 ABLOY LE185...5 ABLOY LE181..6 ABLOY LE183..7 ABLOY LE186..8 ABLOY LE310..9 ABLOY LE314 10 ABLOY LE315 11

More information

Installation Instructions

Installation Instructions H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.

More information

Keypad Programming Instructions for the Profile Series LK and v.g1.5 Locks

Keypad Programming Instructions for the Profile Series LK and v.g1.5 Locks Keypad Programming Instructions for the Profile Series LK and v.g1.5 Locks A7857A 1 2 3 4 5 6 Table of Contents Page LK Programming...14 Transaction Log for LK...45 G1LU, G1PK, G1TU, G1TP Programming...58

More information

PUSH BUTTON START INSTALLATION MANUAL

PUSH BUTTON START INSTALLATION MANUAL PUSH BUTTON START INSTALLATION MANUAL ALTHOUGH THIS PRODUCT HAS BEEN THOROUGHLY TESTED KPIERSON TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR ANY DAMAGE THAT MAY RESULT BY THE INSTALLATION OF THIS PRODUCT.

More information

ViZion Installation Guide

ViZion Installation Guide ViZion Installation Guide v2.0 1 ViZion Installation Guide Table of Contents Inventory Hardware Setup Understanding Synchronization Cable Begin by taking an inventory of the required equipment DR Unit

More information

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Universal Vehicle Power Supply 9007AX01. Installation Instructions Universal Vehicle Power Supply 9007AX01 Installation Instructions Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in

More information

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

Owner's Copy. 104873 December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS

Owner's Copy. 104873 December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS 104873 December 14, 2011 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com ELECTRICAL

More information

10 Line. Cylindrical Lever Locks

10 Line. Cylindrical Lever Locks 10 Line Cylindrical Lever Locks Copyright 2004-2009, 2011, 2013-2015 Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Windstorm Certifications...1 Features

More information

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories System components portfolio overview Power supplies, electromagnetic locks, electric strikes and system accessories Our comprehensive commercial portfolio includes everything you need to hang, protect,

More information

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation

More information

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount

More information

Installation and Operation Guide PD4600 Series Converter Replacement

Installation and Operation Guide PD4600 Series Converter Replacement Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your

More information

Installation and Operation Guide for PD4000 Series Power Control Center

Installation and Operation Guide for PD4000 Series Power Control Center Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1 Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Power Cable 4000950-5 1 Raven Harness Adapter Kit 4100525 1 Installation Instructions

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Analog Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators

Analog Control Wiring & Adjustment Manual for Gyro Tech Swing Door Operators NABCO ENTRANCES Inc. S82 W18717 Gemini Drive Muskego, WI 53150 Phone: 877-622-2694 Fax: 888-679-3319 Technical Assistance: 866-622-8325 www.nabcoentrances.com Email: info@nabcoentrances.com Analog Control

More information

NST11537-3.CDR REV_A 2008-10-07

NST11537-3.CDR REV_A 2008-10-07 NST-.CDR REV_A 00-0-0 00 / 00 Production Year 00 / 00 Model Year MODULE QC DIAGNOSTIC TEST AND 00 / * Production Year 009 / * Model Year Test initiates anytime power is applied to unit. Antenna / Reader

More information

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas

TRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas 162 Ultra-Pin Receptacle, Two Hole Mount Redundant ground through frame No rust, die-cast zinc Heavy bosses for extra rigidity Barrel slanted to drain moisture Mounting holes slotted for universal fit

More information

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive

More information

Datasheet of the Easy Servo Motor ES-MH Series

Datasheet of the Easy Servo Motor ES-MH Series Datasheet of the Easy Servo Motor ES-MH Series High Voltage Stepper Motor with Encoder, 8-20 Nm Version 1.4 http://www.leadshine.com Descriptions Leadshine s ES-MH series easy servo motors, or stepping

More information

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200 FUSION CULTURE TABLE OF CONTENTS There s no point doing something if no one notices. We ve always believed the way to make things happen is by getting

More information

Stand-alone Touchscreen Access Lock ANSI/BHMA Grade 1. An ASSA ABLOY Group brand

Stand-alone Touchscreen Access Lock ANSI/BHMA Grade 1. An ASSA ABLOY Group brand An ASSA ABLOY Group brand Stand-alone Touchscreen Access Lock ANSI/BHMA Grade 1 introduction Yale intouch Stand-alone Touchscreen Access Lock combines robust cylindrical locksets with a contemporary electronic

More information

Operating Instructions. UL325 Compliant Non-monitored

Operating Instructions. UL325 Compliant Non-monitored IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment

More information

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad) KCIENSBP KCIEN Heavy Duty Stainless Steel Illuminated Keypads Range: DIGICODE (Stand-Alone Keypad) INSTALLATION MANUAL Features: Input voltage: 12V to 24V AC or 12V to 48V DC Illuminated keys Heavy duty

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE

INSTALLATION GUIDE. www.security.soundstream.com FCC ID NOTICE AL.1 AUTO SECURITY SYSTEM INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device

More information

Guideline Laser Series

Guideline Laser Series Guideline Laser Series Highly visible alignment laser for visually demanding surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

Technical Information

Technical Information Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1

More information

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS INSTALLATION MANUAL Before you begin the installation Read the INSTRUCTIONS! Always use a multi-meter when verifying vehicle wiring. Before mounting the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L An ISO 9001:2008 Registered Company ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L Introduction The ILISC515-A is a microprocessor driven system for controlling wheelchair

More information

1978-83 Malibu 1978-87 Monte Carlo 1978-87 El Camino

1978-83 Malibu 1978-87 Monte Carlo 1978-87 El Camino Important facts about this kit. 1. The dash panel used in this picture is used by permission of Covan's Classic. 2. This kit requires some modification to your original under dash wiring harness. It is

More information

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions Model PRO 9842 Installation Manual Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions This Unit Is Intended For Installation In Vehicles With 12 Volt Negative Ground Electrical

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev C IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

More information

Cabinet Locks. Benefits:

Cabinet Locks. Benefits: Cabinet Locks Medeco high security cabinet locks are specifically designed for drawer or cabinet door applications where a conventional utility cam lock may not be suitable. Cabinet locks utilize heavy-duty

More information

Life Safety, Security Door Hardware and Integrated Door Security Systems

Life Safety, Security Door Hardware and Integrated Door Security Systems Life Safety, Security Door Hardware and Integrated Door Security Systems Where Trust is Built Life Safety and Security Door Hardware 10 & 40 SERIES RIM EXIT DEVICES 10 SERIES (WIDE STILE) Super heavy duty

More information

PEDAL POWER. User s Manual

PEDAL POWER. User s Manual PEDAL POWER AC User s Manual Copyright 2005-2008 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. No part of it may be reproduced or transmitted by

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

Model: LCDM40 4.0 LCD Rear Vision Mirror Monitor Installation Manual Features

Model: LCDM40 4.0 LCD Rear Vision Mirror Monitor Installation Manual Features Model: LCDM40 4.0 LCD Rear Vision Mirror Monitor Installation Manual Features Mirror with built in 4.0 LCD Monitor Low Profile, Slim Design High Resolution TFT LCD Built in Speaker Two video inputs Fully

More information

FOLGER ADAM PRODUCT CATALOG

FOLGER ADAM PRODUCT CATALOG FOLGER ADAM PRODUCT CATALOG 4634 S. Presa Street, San Antonio, TX 78223 Phone 210-533-1231 Fax 210-533-2211 www.southernfolger.com See who we are. See all we do. FOLGER ADAM TABLE OF CONTENTS TABLE OF

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Single Station Remote Alarm

Single Station Remote Alarm ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

ASSA ABLOY Factory Training Adams Rite HES Securitron Course Offerings

ASSA ABLOY Factory Training Adams Rite HES Securitron Course Offerings ASSA ABLOY Factory Training Adams Rite HES Securitron Course Offerings ADAMS RITE HES SECURITRON ASSA ABLOY is proud to offer the following educational courses covering Adams Rite, HES and Securitron product

More information

Digi-Motor Installation Guide

Digi-Motor Installation Guide Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support

More information

HONDA ACCORD 1985-2005

HONDA ACCORD 1985-2005 HONDA ACCORD 1985-2005 VEHICLE WIRING Copyright 2002-2004 Triple S Customs WIRING INFORMATION: 1985 Honda Accord WIRE WIRE COLOR WIRE LOCATION 12V CONSTANT WHITE or WHITE/BLACK Ignition Harness STARTER

More information

TDAS G5-DB Hardware User s Manual

TDAS G5-DB Hardware User s Manual TDAS G5-DB Hardware User s Manual July 2003 Rev. 1A Table of Contents DTS Support... 3 Introducing the TDAS G5-DB... 4 Summary of TDAS G5-DB Features... 4 Basic Care and Handling... 4 Shock Rating...5

More information

Model PS-4001 Power Supply User Instructions

Model PS-4001 Power Supply User Instructions Model PS-4001 Power Supply User Instructions 9350-7710-000 Rev E 9/2009 PROPRIETARY NOTICE The product information and design disclosed herein were originated by and are the property of Bosch Security

More information

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM INTRODUCTION CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM Thank you for purchasing the CMD-8000 Commander from Dakota Digital. This, along with many other products that Dakota Digital has

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing

More information

PRO PLM Installation Instructions

PRO PLM Installation Instructions PRO PLM Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model 7200ETL Post Mounted Residential & Heavy Duty Commercial Slide Gate Operator INSTALLATION MANUAL 04/11 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications... 4 Pre-Installation

More information

Degree Key System. Technical Manual

Degree Key System. Technical Manual Degree Key System Technical Manual Copyright 03-04, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.

More information

Operating Instructions

Operating Instructions D-TEK Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product

More information

IFS SP-PoE Splitter User Manual

IFS SP-PoE Splitter User Manual IFS SP-PoE Splitter User Manual P/N 1069176-EN REV 1.01 ISS 01JUL10 2011 UTC Fire & Security. All rights reserved. Content Overview 2 Package contents 2 Introduction 3 Product Specifications 3 Hardware

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working

More information

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

Using the NI 17xx Smart Camera Direct Drive Lighting Controller Using the NI 17xx Smart Camera Direct Drive Lighting Controller Overview The use of proper lighting is often overlooked when designing a machine vision application. More robust and accurate inspections

More information

DIRECTIONAL CONTROL VALVES

DIRECTIONAL CONTROL VALVES Series 35 High Flow High Pressure Directional Valves D05SD DIN Type D05S Electrical Box Type D03SD DIN Type D03S Electrical Box Type D03SL Lead Wire Type (D05SL Lead Wire Type Also available) FEATURES

More information

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions EXPLORE 4-Leg Teaming Table with Screen Share Monitor Display Requirements: your flat panel display must confirm to the following requirements. y With the stand removed, the monitor must not exceed 40

More information

Installation and Operation Guide for PD4100 Series Power Control Centers

Installation and Operation Guide for PD4100 Series Power Control Centers Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as

More information

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness WIRING HARNESS FOR AS635P4 ANTENNA NOT USED 5 PIN WHITE PLUG 2 PIN WHITE PLUG GREEN - PARKING BRAKE INPUT (-) BLUE - NOT USED 3 PIN BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

More information

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Applied Electronics. Commercial Dimming System UPDATE NOTICE REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with

More information

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. 7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L Dimmer Module General The Dimmer Pack can be used with any of Tokistar s LED Lighting Systems operating from our 6, 8 or VDC LED Drivers.