B SERIES Photo-Electric Light Curtain Systems

Size: px
Start display at page:

Download "B SERIES Photo-Electric Light Curtain Systems"

Transcription

1 B SERIES TECHNICAL MANUAL Release 10/01/98, ver. 2.0 B SERIES Photo-Electric Light Curtain Systems WARNING Guardstar by Tapeswitch photo-electric safety systems are intended to protect operators working at or near dangerous machinery. They can only perform this function if they are correctly fitted to a suitable machine. It is essential that the full contents of this manual and all the international documents referred to herein are fully understood before any attempt at installation is made. If in doubt contact Tapeswitch Corporation. IMPORTANT This manual must accompany the product throughout its working life. Those persons responsible for the product must ensure that all persons involved in the installation, commissioning, operation, maintenance and servicing of the product have access to all the information supplied by the manufacturers of the machine and its safety system. 1

2 1. GENERAL CONTENTS Page 1.1 INTRODUCTION PRODUCT APPLICATION Typical Applications Suitability PRODUCT STANDARDS PRODUCT FEATURES Safety Integrity Ease of Installation Protection from Environment PRODUCT RANGE General Detection Capability Protected Heights Accessories Mirror Units Mounting Stands ORDERING INFORMATION Light Curtains Cable Options Interface and Programming Units 9 2. TECHNICAL DESCRIPTION 2.1 CURTAIN COMMUNICATIONS TEST INPUT INDICATORS INSTALLATION 3.1 GENERAL MECHANICAL INSTALLATION General Curtain Dimensions Separation Distance Optical Alignment Reflective Surfaces Systems in Close Proximity Mounting Brackets ELECTRICAL INSTALLATION General Emitter Unit General Test Input Receiver Unit General Operation Safety Outputs Serial Communications 24 2

3 Page 3.4 INITIAL CHECKING AND ALIGNMENT INTERFACE AND AUXILIARY UNITS 4.1 GENERAL Methods of Interfacing BSRSA INTERFACE UNIT General Description Operational Sequence and L.E.D. Status Description Mechanical Electrical Connections Fuses Test Input Monitor/Auxilliary Output Technical Specifications BSRUA-2 INTERFACE UNIT General Description Operational Sequence and LED Status Description Configured For ONE Sensing Unit Configured for TWO Sensing Units Mechanical Electrical Connection Fuses Test Input Technical Specifications SRUB INTERFACE UNIT General Description Operational Sequence and LED Status Description Resetting Options Manual Reset Automatic Reset Mechanical Electrical Connection Fuses Monitor Input (manual mode only) External Reset (manual mode only) Monitor/Auxillary Output SRUB Technical Specifications BPU2 HAND HELD PROGRAMMING UNIT (Blanking Unit) GDC-1 POWER SUPPLY LAT LASER ALIGNMENT TOOL PERIODIC CHECKING, SERVICING AND MAINTENANCE 5.1 PERIODIC CHECKING Commissioning Checks or 12 Monthly Checks Daily/Setting Examination Checking Detection Capability SERVICING MAINTENANCE TECHNICAL SPECIFICATIONS (B Series Emitter & Receiver) 48 3

4 1. GENERAL 1.1 INTRODUCTION Guardstar B Series light curtains are through-beam photo-electric machine guarding devices, designed to protect operators working at or near dangerous machinery. When correctly installed on a suitable machine, the system will detect a person (or part of a person) entering a dangerous area in the vicinity of the machine and will signal the dangerous motion to cease before that person can reach a position where injury could occur. Guardstar B Series light curtains use infra-red technology. A curtain of infra-red light is projected across the dangerous area. Intrusion into this curtain by a person, or part of a person, will be detected by the system. This will cause safety output signals to be generated which will stop the dangerous motion of the machine. B Series systems are fully self-monitoring and meet or exceed worldwide requirements for safeguarding devices used on industrial machines. WARNING The information in this manual relates to the use of the basic B Series light curtain, to provide a basic safety switching device. In some applications a B Series light curtain may be used together with other Tapeswitch equipment to provide additional functions and features. The additional information necessary for the correct use of a B Series light curtain when used with other Tapeswitch equipment is provided within this manual. In such cases, some installation parameters, notably the mounting position of the light curtain in relation to the dangerous part of the machine, can be affected and close attention must be paid to all the information supplied with all equipment. INTERNATIONAL CONSIDERATION: The heritage of the Guardstar B Series system is strongly grounded in international commerce and standards. Guardstar is the registered U.S. trade name for the Guardscan products developed by Guardscan, Ltd., of Chorley, England. Both Guardscan and Tapeswitch are part of the Inductotherm Industries, a private, U.S., industrial group.the Guardstar B Series was developed to meet the published and proposed safety standard for U.S.A., Germany, England, Finland, Sweden as well as the common market unified standard. Guardstar systems are manufactured both in England and the U.S.A. Guardstar B Series has been independently third party tested to IEC by BG, and are certified to this standard (CE approval/certification). Contact Tapeswitch for more details. Tapeswitch can provide additional assistance to customers wishing to use the Guardstar B Series guard in international applications. Some foreign language technical manuals are available. 1.2 PRODUCT APPLICATION TYPICAL APPLICATIONS The high level of safety integrity provided by the B Series light curtains makes them suitable for use on many types of machines including some of those presenting the highest risk. Typical applications are: Pinch point protection Power presses Filter presses Robot assembly and welding cells Die casting machines Injection molding machines Special purpose machinery General automated machinery SUITABILITY The most important factors affecting the suitability of a photo-electric guarding device relate to the machine control system. The machine control system must satisfy the following fundamental requirements: (a) The dangerous motion of the machine must be electrically controllable. (b) The machine response/stopping performance must be adequate and consistent. (c) It must be possible to stop the dangerous motion of the machine at any point in its operation. 4

5 (d) The control system as a whole must be constructed to provide and appropriate category of safety integrity as defined in EN954 Safety of machinery: Principles for the design of safety related control systems. The appropriate category of safety integrity should be determined by performing a risk assessment as described in EN1050 Safety of machinery: Risk assessment. Additional factors which may preclude the use of photoelectric devices include: WARNING The B Series light curtain in itself does not guarantee a category 4 safety system has been achieved. Other factors such as stopping time, separation distance and proper interface all contribute to the overall safety level. A safety system is only as strong as its weakest link and in order to maintain a category 4, all devices in the safety system must be category 4. (e) Risk of injury from thermal or other radiation. (f) An environment likely to adversely affect the efficiency of the photo-electric safety system. (g) A tendency for the machine to eject materials or components which are either potentially hazardous to the operator or which interfere with the operation of the safety device. Photo-electric safety systems may be suitable if additional measures are taken to control the risks associated with factors (e) to (g) e.g. local fixed guards to control ejection. 1.3 PRODUCT STANDARDS Guardstar B Series light curtains meet the requirements of the international standard IEC61496 Safety of machinery: Electro-sensitive protective equipment Parts 1 and 2. Each basic B Series light curtain is a complete Active Opto-electronic Protective Device or AOPD. This means that the infa-red used for detection purposes is generated by the system itself. An AOPD is a particular type of Electro-Sensitive Protective Equipment or ESPE. Both of these terms are defined in IEC61496 Parts 1 and 2. Part 1 applies to all types of ESPE and Part 2 covers the particular requirements for AOPDs. B Series light curtains are Type 4 devices as defined by this standard which means that they are fully selfmonitoring and are therefore suitable for use as part of safety related control systems of category 4 (or below) as defined by EN PRODUCT FEATURES SAFETY INTEGRITY Diverse redundancy. Solid State safety outputs. Fully self-monitoring. Test input for system check. Variety of interface units (optional) EASE OF INSTALLATION No interconnection between curtain units. 24 Vdc operation. Adjustable mounting brackets supplied PROTECTION FROM ENVIRONMENT Immune to ambient light. Immune to xenon beacons and strobes. High level of immunity to vibration. High level of electromagnetic immunity. Enclosures sealed to IP65. Polyester powder coating. 1.5 PRODUCT RANGE GENERAL The B Series light curtains are available in a range of different protected heights and detection capabilities. These two parameters are known by many other names and therefore it may be useful to define them here, as they are intended to be used in this manual. To make this clearer it is also necessary to define two further parameters, detection zone and operating range: Detection Zone: This is the actual curtain of infra-red light generated between the emitter and receiver units within which an appropriately dimensioned object will be reliably detected and, for the B Series, can be considered to be a two dimensional, rectangular plane (see figure 1). 5

6 Operating Range: One dimension of the detection zone rectangle is given by the distance between the emitter and receiver units. This is the operating range (see figure 1). Protected Height: The other dimension of the detection zone rectangle is commonly known as the protected height. The word height has been adopted in the latest standards for this equipment because most curtains are mounted vertically. The protected height is often related to, but is not the same as, the length of the emitter and receiver units (see figure 1). Lenses of adjacent beams Lenses of adjacent beams ØY Object ØY - at least one beam is always totally obscured, therefore object is reliably detected. ØX Object ØX - in this position no beams are totally obscured, therefore object may not be detected. X= Spacing or pitch Y=Detection capability Figure 2 Detection Zone Operating Range Figure 1 Detection Capability: This is the minimum dimension of an opaque object which will be reliably detected anywhere within the detection zone. NOTE: The spacing or pitch of the beams or lenses in a light curtain is not the same as the detection capability. The detection capability is always greater than the spacing or pitch. Spacing or pitch should not be used in the calculation of separation distances (see Figure 2) DETECTION CAPABILITY Protected Height B Series light curtains are available with detection capabilities of 14mm, 30mm, or 70mm PROTECTED HEIGHTS B Series light curtains are available with nominal protected heights as follows: Detection Nominal protected heights capability (in mm and inches) 14mm (1/2 in.) mm ( inches) 30mm (1 3/16 in.) mm ( inches) 70mm (2 3/4 in.) mm ( inches) minimum separation distance is 0.5m. Note: The actual protected height is 8mm greater than the nominal protected height ACCESSORIES Mirror Units A range of mirror units are available to enable a single curtain to be used to guard two or three sides of a machine or to avoid structural obstructions. 6

7 The mirror assembly consists of a high quality silver backed glass mirror adhesively attached to a length of extruded aluminum. Two pivot brackets are bolted to the aluminum extrusion and can be adjusted anywhere along the length for mechanical attachment. The actual length of the mirror is 4 inches (1000mm) larger than the active curtain length to accommodate a wide tolerance for height alignment. All of the necessary hardware is supplied to facilitate mounting to the mounting/floor stands. The dimensions of the pivot brackets, extruded aluminum and overall mirrors are shown below in millimeters. Pivot Bracket X Pivot Brackets (180 Rotation; Distance X is Adjustable) Glass Reflective Surface Overall Length = Protective Height + 4" 180 Rotation in this Plane Supplied with: mm x 40mm extrusion, 100mm larger than protective height silver backed mirror, 100mm larger than protective height pivot joints mm x 40mm end covers mm T slot nuts #12 flat washers mm spring washers mm x 5/8 hex bolts. Extrusion Dimensions Curtain Lengths Mirror Assembly Length P/N 200mm - 8" 300mm - 12" mm - 12" 400mm - 16" mm - 16" 500mm - 20" mm - 24" 700mm - 28" mm 800mm - 32" 900mm - 36" mm - 36" 1000mm - 40" mm 1000mm - 40" 1100mm - 44" mm - 48" 1300mm - 52" mm 6.8mm 1400mm - 56" 1500mm - 60" 0968 For units greater than 56 inch, custom mirrors are available. 7

8 Mounting Stands Model Number Part Number Floor mounting stands are available for use where the guard cannot be mounted directly to the machine. B/8"(208mm)/ B/12"(308mm)/ B/16"(408mm)/ P/N 0957 B/24"(608mm)/ leveling bolts 3/8" holes 5 Supplied with: 1. 5 ft. item 40mm X 40mm extrusion base stand mm X 40mm end cap T slot nuts M M5 X12mm hex head M5 spring lock washers flat washers 5/5.3mm /16 bolts /8 24 x 1/2" hex head. B/32"(808mm)/ B/36"(908mm)/ B/40"(1008mm)/ B/48"(1208mm)/ B/56"(1408mm)/ B/64"(1608mm)/ " 4" 4" 5" B/72"(1808mm)/ B/8"(2008m)/ The mounting stands come with a floor base which a 5 foot tower secures into. The floor base is steel and can be permanently mounted to the floor surface with the pre-drilled mounting holes. The tower is extruded aluminum with slots to allow the light curtain to be positioned anywhere along the 5 foot section. The mounting stands are supplied with all of the necessary hardware to facilitate mounting the standard B Series light curtain. Leveling bolts allow for minor adjustments to the floor stand. 1.6 ORDERING INFORMATION LIGHT CURTAINS Part numbers on the following table should be used for ordering. The units will be marked according to the model as follows: B / XXXX / XX Nominal protected height Detection capability (in millimeters or inches) - (in millimeters) - see section mm, 30mm or 70mm for available sizes B/12"(3008m)/ B/16"(4008m)/ B/24"(608mm)/ B/32"(808mm)/ B/36"(908mm)/ B/40"(1008mm)/ B/48"(1208mm)/ B/24"(608mm)/ B/32"(808mm)/ B/40"(1008mm)/ B/48"(1208mm)/ B/56"(1408mm)/ B/64"(1608mm)/ B/72"(1808mm)/ B

9 1.6.2 CABLE OPTIONS Order cable options using the following part numbers: INTERFACE AND PROGRAMMING UNITS (see electrical interface and operation for technical detail) Order interface and programming units using the following part numbers: Description BSRSA - Metalic Wall Mount Interface BSRUA/2 Part Number Din Rail Mount Interfac e 0951 SRUB - 24VDC Safety Relay Interface GDC1-240/120VAC to +24DC Power Supply BPU2 SRUM LAT Description Part Number Emitter Cable (molded 15 feet) 0972 Emitter Cable (molded 30 feet) 0973 Receiver Cable (molded 15 feet) 0974 Receiver Cable (molded 30 feet) Blanking Unit Muting Controlle r Laser Alignment Too l TECHNICAL DESCRIPTION 2.1 CURTAIN A basic B Series light curtain consists of two units: an emitter unit and a receiver unit. Both units are identical in shape and size. The units are enclosed in a robust extruded aluminum section with reinforced composit end covers. The emitter and receiver units together generate a curtain of infra-red light between them. This curtain is mounted in such a position in relation to the dangerous parts of a machine that a person or part of a person approaching those dangerous parts must first penetrate the curtain. This penetration is detected by the light curtain system and, by means of its output switching devices, the light curtain system causes the dangerous parts to go to a safe state (e.g. by stopping moving parts) before the person can reach them. IMPORTANT From the information above, it can be seen that safe use of a light curtain relies not only on the safety integrity of the curtain itself but also on its proper mechanical and electrical interfacing to the machine. The safety integrity of the light curtain itself is the responsibility of Tapeswitch and the remainder of this section describes the features of the design by which safety integrity is ensured. Proper mechanical and electrical interfacing is the responsibility of the user. Comprehensive information for this purpose is provided in section 3 and 4 of this manual. The emitter unit contains a number of infra-red light emitting diodes (LEDs). The quantity and spacing of these LEDs depends on the protected height and the detection capability of the particular light curtain. The devices are arranged equally spaced in an array. The receiver unit contains a corresponding number of infra-red photodiodes similarly arranged. 9

10 Each LED and photodiode is fitted with a precision lens which gives an evenly intense, slightly diverging beam of infa-red from each LED and a evenly sensitive, slightly converging reception cone into each photodiode. This arrangement provides a high signalto-noise ratio and maximum operating range for the system together with ease of alignment and rejection of extraneous reflected light sources. The function of each LED and photodiode is controlled by its own dedicated, purpose designed ASIC (Application Specific Integrated Circuit). All the circuitry necessary for the operation of an LED or photodiode is contained within this single component, resulting in a very low component count and consequent improvement in reliability for the system. For each LED in the emitter unit there is a corresponding photodiode in the receiver unit, the same relative position within the unit. Each LED/photodiode pair makes a beam and the curtain is made up of a number of such beams, all parallel to each other. (See Figure 3.) Beam 1 Each receiver ASIC in its turn generates an output signal which is proportional to the level of infa-red it receives from its corresponding LED. Signals from other sources, such as background lighting, are filtered out inside the ASIC. There is one micro processor in the emitter unit and two in the receiver unit. All three micro processors perform exhaustive checks on their own hardware and software, prior to and during operation. The two in the receiver unit continually communicate their results to each other such that if a fault occurs in one device the other can shut the system down. In the receiver unit there are two independent switching channels each containing an output signal switching device (OSSD). Each of the two microcontrollers in the receiver unit controls one of these OSSDs and monitors the other. The OSSDs are very robust solid state devices. These devices are intended to be connected directly to the machine control system, a Tapeswitch/Guardscan interface unit or a suitable safety relay such that if one or both of them are in the OFF state, the machine will go to or remain in a safe condition, for example, by stopping dangerous motion or by preventing dangerous motion from starting. 2.2 COMMUNICATIONS The receiver unit incorporates a serial communications port. Various auxiliary Tapeswitch equipment can be connected to this port for the purposes of programming functions within the light curtain and for interrogating the system. No equipment other than Tapeswitch equipment should be connected to this port. Full instructions for the use of this port with auxiliary equipment is provided within this manual. 2.3 TEST INPUT Figure 3 Only one LED and one photodiode are active at any time. The emitter unit runs independently from the receiver unit. There are no connections between the units. The emitter unit activates each of its LEDs in turn and the receiver unit synchronizes with the emitter unit. A pair of terminals is provided across which a pair of normally closed, volt free contacts should be connected. When these contacts are opened the emitter unit will stop scanning, forcing the OSSDs to the OFF state. This input simulates a curtain obstructed condition. NOTE: This input is provided to allow the B Series to be used with machine control systems which need to cycle the safety circuit prior to operation. The B Series system itself does not require this input to be used. If this input is not used it should be jumpered and remain jumpered at all times. 10

11 2.4 INDICATORS The receiver unit has four indicators as shown in Figure 4. The emitter unit has two indicators as shown in Figure 5. A description of each indicator is given in Table 1. Unit Color Description Emitter A mber Lit when power is connected to unit. Red Lit steady when test input is applied. Lit flashing when emitter unit is faulty. A mber Lit when power is connected to unit. G reen Lit when curtain is clear. Receiver Red Yellow Lit brightly when curtain is obstructed. L it dimly when the curtain is clear. Lit flashing when receiver unit is faulty. Lit steady when curtain has been programmed to a state other than no blanking. Table 1 Amber Yellow Amber Red Green Red Figure 4 Receiver Figure 5 Emitter 11

12 3. INSTALLATION 3.1 GENERAL WARNING Guardstar B Series systems are designed to protect operators working at or near dangerous machinery. They can only perform this function if they are correctly fitted and interfaced to a suitable machine. Those persons responsible for the machine must ensure that all persons involved in the installation of the photo-electric safety system have the necessary knowledge, training and experience and that they are fully aware of all laws, rules, regulations and codes of practice pertaining to their task. The attention of the installer is drawn to following general requirements for the installation of a B Series system: (a) The dangerous motion of the machine must be electrically controllable. (b) The machine response/stopping performance must be adequate and consistent. (c) It must be possible to stop the dangerous motion of the machine at any point in its operation, in any operating mode. (d) The control system as a whole must be designed and constructed to provide the appropriate category of safety integrity as defined in EN954 Safety of machinery: Principles for the design of safety related control systems. The appropriate category should be as prescribed in the relevant C type EN standard for the type of machine concerned. In the absence of such a standard the appropriate category of safety integrity should be determined by performing a risk assessment as described in EN1050 Safety of machinery: Risk assessment. (e) Steps must be taken to prevent access to the dangerous parts of the machine from any direction not covered by the photo-electric curtain. Such steps could include fixed or interlocking fences or screens, additional photo-electric devices or pressure sensitive mats. Similar steps should be taken to prevent a person standing between the curtain and the dangerous parts. (f) No devices other than those specified in this manual should be connected to the internally generated power supply of the system. (g) After installation the machine/guard system must be commissioned in accordance with the requirements of section of this manual. (h) Any covers removed during installation must be replaced as soon as possible. (i) After the curtain has been actuated it must not be possible for the machine to restart until a manual control has been operated. This is known as restart interlock. The basic B Series does not provide this function. The function of the basic B Series system is GUARD ONLY i.e. when the curtain is clear the outputs are ON and when the curtain is broken the outputs are OFF. 3.2 MECHANICAL INSTALLATION GENERAL ANSI B gives guidance on the dimensions and positioning of photo-electric safety devices fitted to industrial machines. The main considerations are described below and are illustrated in Figure 6. (a) The appropriate protected height must be selected. The curtain must be of sufficient height such that access to the dangerous parts, from the direction of approach of the operator, is only possible by obstructing the curtain taking into account all possible operator positions. (b) The correct minimum separation distance must be observed. The curtain must be mounted in the correct position in relation to the dangerous parts of the machine to take account of the stopping performance of the machine, the curtain format used and the detection capability of the curtain. (c) Steps must be taken to prevent access to the dangerous parts from any direction not covered by the curtain and to prevent an operator from standing between the curtain and the dangerous parts without obstructing the curtain. Additional mechanical guarding will usually be necessary to achieve this. The physical parameters affecting the positioning are the dimensions of the detection zone of the light curtain (i.e. the protected height and the range) and the minimum separation distance. These are described in the following sections. 12

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

MULTI-BEAM LS10 Light Screen System

MULTI-BEAM LS10 Light Screen System For Sensing Small Parts at High Speeds Emitter and receiver pair produce a strobed array of modulated light beams to produce a light screen Simple, economical and highly reliable means of sensing small

More information

High Performance Visible Laser Diode Scanners

High Performance Visible Laser Diode Scanners A B ALLEN-BRADLEY High Performance Visible Laser Diode Scanners (Catalog No. 27-LD4z1, -LD4z4 27-LD8z1, -LD8z4) Product Data These high performance, fixed-mount scanners use a Visible Laser Diode (VLD)

More information

F-Series Camera Mounting Accessories

F-Series Camera Mounting Accessories F-Series Camera Mounting Accessories Document Number: 427-0462-00-12 Version: 100 Issue Date: September 2010 2010. All rights reserved worldwide. FLIR Commercial Systems, Inc. 70 Castilian Drive Goleta,

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

intelligent solutions

intelligent solutions Lichtschranken W 8- Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 8-: Integrated stateof-the-art technology

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions

More information

AXIS T81B22 DC 30W Midspan

AXIS T81B22 DC 30W Midspan INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial

More information

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Application Technique. Safety Function: Magnetic Door Switch Monitoring Application Technique Safety Function: Magnetic Door Switch Monitoring Products: MC1 Magnetically-coded Door Switch, Guardmaster Dual-input Safety Relay Safety Rating: CAT. 3, PLd to EN ISO 13849-1: 2008

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

Universal Voltage Terminal Photoelectric E3JM

Universal Voltage Terminal Photoelectric E3JM Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or

More information

SAFETY LIGHT CURTAINS

SAFETY LIGHT CURTAINS SAFETY LIGHT CURTAINS Overview Safety Light Curtains with resolutions that can be reduced guarantee protection and tolerate work equipment in the protective field The Safety Light Curtains comply with

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

Guide to Safety Edge Systems

Guide to Safety Edge Systems Guide to Safety Edge Systems Tel: 0845 054 5070 asosafety@egduk.com Guide to Safety Edges All new automatic gate & door systems installed in the UK should comply to BS-EN13241-1 & EN-138491-1 harmonised

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop

More information

DLO1191 Linear smoke detector

DLO1191 Linear smoke detector DLO1191 Linear smoke detector collective/synoline600, interactive AlgoRex Synova Reliable smoke detection in large-volume rooms (inside application) Detection distance from 5 100 Meter Efficient signal

More information

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction GEH6290 g Cable Operator Mechanisms for E150, SE150, SF250, and SG600 Spectra RMS Circuit Breakers Type SCH1/1X, SCH2/2X Flange-Mounted Handle Assemblies, Cable Series SC3L SC10L and Type SC0M1A, SCOM1EF,

More information

-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX

-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX -1-002085 CONE SETTER PLATFORM ATTACHMENT INDEX I. GENERAL EQUIPMENT : A. Intent Statement B. Cone Setter Platform II. III. 1. Understructure Frame 2. Mounting Components 3. Paint 4. Basket 5. Labels 6.

More information

Operating Instructions

Operating Instructions D-TEK Vehicle Loop Detector Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

Safety Light Curtains. We make safety easy.

Safety Light Curtains. We make safety easy. Safety Light Curtains. We make safety easy. When Safety Matters, We ve got you covered. TR Electronic is an industry leader in manufacturing and supporting a complete line of absolute rotary encoders,

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

BSE Geluid en Licht Pagina 1 van 5. Description

BSE Geluid en Licht Pagina 1 van 5. Description Description The MiniMAC Profile is an automated moving-head spotlight that provides 12 dichroic color filters, 7 interchangeable rotating gobos, high-speed mechanical shutter, 540 of pan by 270 of tilt,

More information

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version OLYM-S24D-C24D The Olympus 4HD is a heavy duty solenoid controlled access lock available with either a stainless steel tongue actuator or a heavy duty handle. The Olympus 4HD is capable of supporting Category

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

RAY-MAX Integrated Solar Power Strip

RAY-MAX Integrated Solar Power Strip RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...

More information

W 260: Standard photoelectric switch series for a broad range of applications

W 260: Standard photoelectric switch series for a broad range of applications W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of

More information

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCR3.2/.. Chipcard reader HOTEL SOLUTION s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages

More information

W150: Miniature photoelectric switch series with completely integrated electronics

W150: Miniature photoelectric switch series with completely integrated electronics Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

Operating Instructions. UL325 Compliant Non-monitored

Operating Instructions. UL325 Compliant Non-monitored IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION DATE: October 2012 DESCRIPTION: ARB Intensity LED Lights APPLICATION: Auxiliary Driving Light PART NO. : AR32F - Flood beam AR32S - Spot beam RETAIL: $763.26 each AVAILABILITY DATE: December 2012 PRODUCT

More information

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors. www.illuminated-mirrors.uk.com

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors. www.illuminated-mirrors.uk.com Illuminated Mirrors The UK s Largest LED Mirror Supplier to Trade and Retail Installation & User Guide Bathroom Cabinet www.illuminated-mirrors.uk.com Bathroom Cabinet Installation & User Guide Thank you

More information

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic

More information

W 27-2: The photoelectric switch series with expanded possibilities

W 27-2: The photoelectric switch series with expanded possibilities W - Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W -: The photoelectric switch series with expanded possibilities metres

More information

ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com

ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com StructureScan HD Transom mount Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Warning: It is your sole responsibility to install and use the instrument and transducer(s)

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared

More information

Three Channel Optical Incremental Encoder Modules Technical Data

Three Channel Optical Incremental Encoder Modules Technical Data Three Channel Optical Incremental Encoder Modules Technical Data HEDS-9040 HEDS-9140 Features Two Channel Quadrature Output with Index Pulse Resolution Up to 2000 CPR Counts Per Revolution Low Cost Easy

More information

SYSTEM 4C. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25

More information

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1

Part Name/Description Part Number Quantity. Power Cable 4000950-5 1 Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Power Cable 4000950-5 1 Raven Harness Adapter Kit 4100525 1 Installation Instructions

More information

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and

More information

POLE MOUNT SYSTEM EX-3 INSTALLATION

POLE MOUNT SYSTEM EX-3 INSTALLATION May 2014 POLE MOUNT SYSTEM EX-3 INSTALLATION The Pole Mount System EX-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker systems to be mounted to pole structures. The

More information

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat

More information

The quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers.

The quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers. Quick Assembly Two and Three Channel Optical Encoders Technical Data HEDM-550x/560x HEDS-550x/554x HEDS-560x/564x Features Two Channel Quadrature Output with Optional Index Pulse Quick and Easy Assembly

More information

W 36: Mastering complex tasks reliably

W 36: Mastering complex tasks reliably Lichtschranken W Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches W : astering complex tasks reliably Through-beam photoelectric switches for temperatures

More information

SureSite Magnetic Liquid Level Indicator

SureSite Magnetic Liquid Level Indicator SureSite Magnetic Liquid Level Indicator Instruction Bulletin No. 177664-1 (Rev. E) Section 1: Weldments Thank you for purchasing the GEMS SureSite Magnetic Level Indicator. Please read this document prior

More information

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator The Janus Pantheon mini operator does not typically require the provision of any additional site requirements other than

More information

3 3RG78 45 program overview

3 3RG78 45 program overview Overview RG78 45 light curtains and arrays with integrated processing unit for type 4 in accordance with IEC/EN 61496 With "Standard" function package Resolutions: 14, 0, 50, and 90 Protective zone height:

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:

More information

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,

More information

Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012

Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012 Operating instructions Optical distance sensor UK O1D100 O1D103 704991 / 00 08 / 2012 Contents 1 Preliminary note4 1.1 Symbols used 4 1.2 Warning signs used 4 2 Safety instructions 4 3 Functions and features

More information

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output 133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

Wolflite Safety Handlamp H-251E

Wolflite Safety Handlamp H-251E Wolflite Safety Handlamp H-251E & H-251 Mk1 & Mk2 Wolflite Safety Handlamp H-251E H 18Y H 17 H 31Y H 21A H 30 H 24 H 26 H 19 H 25 H 03 H 15Y H 22 H 104 H 29 H 66 H 13 H 14 H 09 H 12 H 48 H 11 H 62 H 63

More information

Machinery Safety. Presented by Paul Laidler. TÜV SÜD Product Service

Machinery Safety. Presented by Paul Laidler. TÜV SÜD Product Service Machinery Safety Presented by Paul Laidler Machinery Division Safety Solutions Assistance in meeting the requirements of machinery safety legislation Machinery, Low Voltage and Electro Magnetic Compatibility

More information

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete. LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and

More information

General 1-2-Opto-electronics Safety Switches 4-Emergency

General 1-2-Opto-electronics Safety Switches 4-Emergency General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

Original instructions Tina 3A/Aps Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

IO-DIM6 6-Channel, Digital to Analogue Converters

IO-DIM6 6-Channel, Digital to Analogue Converters Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine

More information

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1 SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration

More information

StructureScan Installation

StructureScan Installation StructureScan Installation Contents Your StructureScan box is packed with the LSS-1 black box, a Power cable, StructureScan transducer, mounting bracket, 15 foot (4.5m) ethernet cable and a hardware kit.

More information

CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device

CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device SIMATIC PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device Introduction 1 Preparation 2 Learning units 3 Further Information

More information

Small Optical Encoder Modules 480lpi Digital Output. Features. Applications VCC 3 CHANNEL A 2 CHANNEL B 4 GND 1

Small Optical Encoder Modules 480lpi Digital Output. Features. Applications VCC 3 CHANNEL A 2 CHANNEL B 4 GND 1 HEDS-9730, HEDS-9731 Small Optical Encoder Modules 480lpi Digital Output Data Sheet Description The HEDS-973X is a high performance incremental encoder module. When operated in conjunction with either

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

Laserlyte-Flex Alignment System

Laserlyte-Flex Alignment System Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning

More information

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling

More information

1701/22 FieldMonitor Management Interface Module

1701/22 FieldMonitor Management Interface Module 1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions QUICK LINKS Mounting Location Guidelines Open the Sensor Mount the Sensor Sensor Components and Settings Wire the Sensor

More information

SYSTEM DESCRIPTION Termination Boards

SYSTEM DESCRIPTION Termination Boards PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following

More information

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

W 2: Subminiature photoelectric switch series: extremely small and extremely strong Photoelectric proximity switches BGS Photoelectric proximity switches energetic, (V optics) Photoelectric reflex switches Through-beam photoelectric switches W : Subminiature photoelectric switch series:

More information

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature LED LEONARDO 120 W LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature OVERVIEW The LED LEONARDO 120W is a highly efficient Fresnel lens spotlight using

More information

Automated Bottle Filling System

Automated Bottle Filling System Automated Bottle Filling System Bipin Mashilkar 1, Pallavi Khaire 1, Girish Dalvi 1 1 Assistant Professor, Department of Mechanical Engineering, Fr.C.Rodrigues Institute of Technology, Maharashtra, India

More information

How To Power A Schen

How To Power A Schen Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter. ACS-101 Amplified Broadband UHF Combiner-Splitter General Description The ACS-101 (Antenna Combiner Splitter 10 to 1) is an amplified and filtered broadband splitter-combiner. It allows up to 10 base stations

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

PALLETS ROLLER CONVEYOR LOADING CONVEYOR CHAIN TRANSFER TURNTABLE ROLLER STOP

PALLETS ROLLER CONVEYOR LOADING CONVEYOR CHAIN TRANSFER TURNTABLE ROLLER STOP AUGUST 12, 2014 INDEX 04 07 04 06 EMITTER REMOVER 07 08 10 12 14 BOXES BELT CONVEYOR BELT CONVEYOR GATE STRAIGHT SPUR CONVEYOR CONVEYOR SCALE 16 17 18 19 20 22 24 26 ALIGNERS WHEEL ALIGNER BRACKET CHUTE

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information