Pneumatic Temperature Controllers
|
|
- Adrian Taylor
- 7 years ago
- Views:
Transcription
1 Pneumatic Controller A,C,D Dimensions in inches (millimeters) 3 (7) INIU CLEARANCE /8 (3) INIU SPACING BETWEEN ODULES A: -/2 (36) B-D: 3-/4 (83) RP9A: -7/8 (48) B-D: 3-3/6 (96) 4 (2) 9/32 (7) Typical Single-Input Control System OUTDOOR RETURN DAPER ACTUATOR B 3-3/8 (86) LIIT CONTROLLER A R.A. 2 3 VENT 2 E-P 3 RELAY Pneumatic Temperature Controllers -7/8 (48) RP97A IXED CONTROL SYSTE 2 4 SP97 INIU POSITION REGULATOR, high capacity, single or dual input used in conjunction with sensors to provide proportional (P) or proportional (P+I) control of temperature, humidity, pressure, or dopant for heating and air conditioning systems. Replacement devices are available for Johnson, Powers, Robertshaw, Barber-Colman, and older Honeywell s. control option minimizes offset. iniature diaphragm technology provides high degree of accuracy and reliability. models can be converted to Reverse (RA) function in field. Field adjustable compensation start point. Local or setpoint field option. Integral action cut-off provides trouble-free automatic startup. Transparent cover (optional) provides protection while allowing easy reading of settings and gages. Corrosion resistant construction. Typical Dual-Input Control System PRIARY CONTROLLER C 7 I FRO FAN INTERLOCK PRIARY SENSOR COPENSATION SENSOR (OUTDOOR ) 2 3 D.A. STEA 7 6 PRIARY SENSOR B OR D.7 IN. RESTRICTION (COIL DISCHARGE) (TEPERATURE) 2 3 CPA 2 4 OPTIONAL CPA ODELS ONLY A OR C DA HOT WATER CONVERTER CONTROL SYSTE TO CONVERTER C336- PRIARY SENSOR IN HW LINE C87-2 Indoor Air Quality Combustion Hydronic Building Automation
2 Pneumatic Temperature Controllers Airflow Usage:.7 scfm (33. ml/s) with psi (7kPa) pressure drop at 8 psi (24 kpa) main air supply Connections: Air: Combination /32 in. by /4 in. barb. Optional accessory 437- (barb fitting for port 4,6,7, or 8 for all ). Input Signal: 3 to psi (2 to 3 kpa) aximum Operating Temperature: 3 F (4 C) Temperature Range: 4 F to 3 F ( C to C) aximum Operating : 3 psi (7 kpa) Humidity Ratings: to 9% RH Remote Bulb Sensor: no Remote Control Point Adjustment: Yes Accessories: Temperature and Humidity scaleplate insert for setpoint knob for all DIN Rail ount Receiver Gauge, 2 F-2 F scale, /2 in. diameter, Receiver Gauge, to 7% RH scale, /2 in. diameter, Receiver Gauge, 6 to 9% RH scale, /2 in. diameter, Receiver Gauge, to 8% RH scale, /2 in. diameter, Receiver Gauge, - to C scale, /2 in. diameter, /4 inch (3 mm) long mounting rail for /4 inch (4 mm) long mounting rail for 366 -/2 in. diameter, /8 NPT center stem back mount Receiver gauge ( to 2 in. w.c. scale) with +/- 2% accuracy 396 -/2 in. diameter, /8 NPT center stem back mount Indicating gauge ( to 3 psi scale) with +/- 4% accuracy /2 in. diameter, /8 NPT center back stem mount Receiver gauge (-4 to +6 F scale) with +/- 2% accuracy 393 -/2 in. diameter, /8 NPT center back stem mount Receiver gauge ( to F scale) with +/- 2% accuracy 393 -/2 in. diameter, /8 NPT center back stem mount Receiver gauge (4 to 24 F scale) with +/- 2% accuracy 3972 Receiver gauge, -/2 in. /8 NPT center back, temperature to F 3986 Receiver Gauge. - to 8 F scale -/2 in. diameter,/2 NPT Clear plastic cover for all A s Clear plastic cover for all B, C, D s Replacement Parts: 486- Filter Cartridge Assembly Gage Tap repair plug Seal screw for port 8 and O-ring repair parts for Compensation module with gasket for B and D Setpoint module with gasket with CPA for Connector block with gasket and CPA for O-ring for filter in Setpoint knob for all s Product Number Application Action Capacity A2 A33 B23 B3 C2 C39 D29 Number of Sensors at 8 psi (24 kpa) single LP and 8. psi (9 usage):.2 scfm ( ml/s) at 8 psi (24 kpa) single LP and 8. psi (9 usage):.2 scfm ( ml/s) at 8 psi (24 kpa) dual LP and 8. psi (9 (2.7 ml/s) at 8 psi (24 kpa) dual LP and 8. psi (9 (2.7 ml/s) at 8 psi (24 kpa) single LP and 8. psi (9 usage):.2 scfm ( ml/s) at 8 psi (24 kpa) single LP and 8. psi (9 usage):.2 scfm ( ml/s) at 8 psi (24 kpa) dual LP and 8. psi (9 (2.7 ml/s) Output Range (psi) (kpa) Comments All s can be All s can be All s can be All s can be All s can be All s can be All s can be Includes 694 customer.honeywell.com 7-69
3 Pneumatic Temperature Controller Accessories Pneumatic Temperature Controllers Product Number Description Used With Receiver Gauge, 2 F-2 F scale, /2 in. diameter, Receiver Gauge, - to C scale, /2 in. diameter, Receiver Gauge, to 7% RH scale, /2 in. diameter, /8 in. NPT Receiver Gauge, 6 to 9% RH scale, /2 in. diameter, /8 in. NPT Receiver Gauge, to 8% RH scale, /2 in. diameter, /8 in. NPT Repair kit including filters, screens, washers, gaskets, O-rings, and restrictors RP98 for RP98A and RP98B s Compensation module with gasket for B and D DIN Rail ount /4 inch (3 mm) long mounting rail for /4 inch (4 mm) long mounting rail for 366 -/2 in. diameter, /8 NPT center stem back mount Receiver gauge ( to 2 in. w.c. scale) with +/- 2% accuracy 367 -/2 in. diameter, /8 NPT center stem back mount Receiver gauge (. to 3. in. w.c. scale) with +/- 2% accuracy /2 in. diameter, /8 NPT center back stem mount Receiver gauge (-4 to +6 F scale) with +/- 2% accuracy 393 -/2 in. diameter, /8 NPT center back stem mount Receiver gauge ( to F scale) with +/- 2% accuracy 393 -/2 in. diameter, /8 NPT center back stem mount Receiver gauge (4 to 24 F scale) with +/- 2% accuracy 396 -/2 in. diameter, /8 NPT center stem back mount Indicating gauge ( to 3 psi scale) with +/- 4% accuracy 3972 Receiver gauge, -/2 in. /8 NPT center back, temperature to F Clear plastic cover for all A s Clear plastic cover for all B, C, D s CCT83 Slide Rule for Calculating Pneumatic Controller Settings for all RP98 and 's. RP98; PSI (-7 kpa) C842 Indoor Air Quality Combustion Hydronic Building Automation Pneumatic Temperature Controller Replacement Parts Product Number Description Used With Seal screw for port 8 and O-ring repair parts for Setpoint module with gasket with CPA for Connector block with gasket and CPA for Setpoint knob for all s O-ring for filter in
4 Pneumatic Controllers PP9; PP92 Reducing Valves Used to control the pressure of the air delivered to control systems. odels available for single-pressure systems or two-pressure systems (Day/Night or Summer/Winter) requiring two independently regulated pressure settings. Dual-pressure units switch from the lower settings to the higher settings when main air is applied to the pilot port. odels also available including a submicron filter assembly and pressure gauges. Replacement devices are available for Johnson, Powers, Robertshaw, Barber-Colman and older Honeywell pressure reducing valves. Built-in adjustable safety relief valve for limiting downstream pressure. For two-pressure models: changes accomplished with manual switch or automatically with electric switch. Adjustable stops for desired settings. PP9 PP92 PP9 Dimensions in inches (millimeters) PP92 Dimensions in inches (millimeters) - / 2 (38) 2-/4 (7) -3/8 (3) /8 NPT SWITCHOVER INLET PORT (PP9B ONLY) 8-/8 (29) CONNECTION 4-7/8 (24) /8 () /4 NPT INLET /4 NPT OUTLET psig psig /8 (244) 3-/4 (83) C46-3/4 (46) PP92D Typical Operation TO AUTOATIC OR ANUAL SWITCHOVER CONTROL EP RELAY C32 PP92C Typical Operation EX 2 3 FRO COPRESSOR IN OUT REDUCED PRESSURE TO SYSTE FRO COPRESSOR FILTER IN PRV OUT REDUCED PRESSURE TO SYSTE C44 FILTER PRV C43 Application Type: Reducing Connection Size: Inlet and out air: /4 in. NPT (female) Air gage: /8 in. NPT (female) ounting: Bracket furnished Accessories: in. diameter, /4 NPT center stem back mount Indicating gauge ( to 6 psi scale) with +/- 3% accuracy 396 -/2 in. diameter, /8 NPT center stem back mount Indicating gauge ( to 3 psi scale) with +/- 4% accuracy 849E 2-/2 in. diameter, panel-mounted Pneumatic Indicating Gauge ( to 6 psi),, +/-3% accuracy Replacement Parts: Filter for PP92A or B 443- Filter cartridge kit for PP92C and PP92D Filter Station Assembly for PP9, PP92A or B 3634B PP9A & B Diaphragm Repair Kit 363A Regulator Valve Assembly, PP9A & PP9B, PP92A,B. 696 customer.honeywell.com 7-69
5 Pneumatic Controllers Product Number PP9A4 PP9B2 PP92C9 PP92D7 Inlet Range PP93 Pneumatic Differential trol One-pipe, pressure operated device used to provide proportional control of valve or damper actuators by varying the pressure to the actuators in relation to the pressure difference between two separate water pressures. Replacement devices are available for Johnson, Powers, Robertshaw, and older Honeywell pressure s. Easily accessible s. (DA) or Reverse (RA) setting. ounting lugs for quick mounting. Dimensions in inches (millimeters) 8-/8 (29) Output Range (psi) (kpa) (psi) (kpa) psi psi psi psi 3 to 34 kpa 3 to 34 kpa 3 to 34 kpa 3 to 34 kpa adj. to 2 psi. adj. to 2 psi; adj. to psi above primary rating adj. to 2 psi adj. to 2 psi; adj. to psi above primary rating adj. to 72 kpa. adj. to 72 kpa; adj. to 34kPa above primary setting. adj. to 72 kpa. adj. to 72 kpa; adj. to 34kPa above primary setting. Description Includes High Diaphragm Operated Reducing Valve with Built-in Adjustable Relief Valve for Single Systems. Includes ounting Bracket and Gage Taps But No Gages. High Diaphragm Operated Reducing Valve with Built-in Adjustable Relief Valve for Dual Systems. Includes ounting Bracket and Gage Taps But No Gages. Reducing Valve for Single Systems, consists of a PP9A Valve, a submicron filter station, 2 psig gages, Interconnecting Pipe Fittings, and a ounting Bracket Reducing Valve for Dual Systems, consists of a PP9B Valve, a submicron filter station, 2 psig gages, Interconnecting Pipe Fittings, and a ounting Bracket PP93A Typical Piping RETURN AIN HAND TEE PP93A TEE AIN HAND Gage tapping to measure the regulated pressure. Gage tapping to measure the regulated pressure. Submicron filter assembly and two psig gages. Submicron filter assembly and two psig gages. Indoor Air Quality Combustion Hydronic Building Automation 9-/6 (246) 3-/6 (84) 2778 Application Type: Differential Connection Size: Input: /4 in. NPT; Branch Line: /8 in. NPT Range: to 3 psi ( to 68 kpa) RESTRICTION HEAT EXCHANGER PUP 423 Approximate Throttling Range, idscale (max.): 2 psi (72 kpa) ounting: Lugs for 3-point surface mounting Actuator Force aximum Operating Differential Range Product Number Action (psi) (kpa) (psi) (kpa) (psi) (kpa) PP93A36 Reverse, 7. psi 2 kpa 8 psi 24 kpa to 6 psi 34 to 448 kpa
Powers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
More informationRC 195 Multiple Input Receiver-Controller
Document No. 129-230 RC 195 Multiple Input Receiver-Controller Product Description The RC 195 Multiple Input Receiver-Controller is a pneumatic instrument that can be used as a one input (DA or RA), two
More informationGeneral Information... 2
Pneumatic VAV Reset Volume Controllers CSC 2000 Series Applications Guide General Information... 2 CSC 2000 Series Overview...2 odels and Specifications...3 ounting...4 Connections...4 All Units...4 Beige
More informationPowers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
More informationPowers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
More informationPOWERS CONTROL RC 195 Single Input Receiver-Controller
Document No. 155-119P25 RC 195-4 POWERS CONTROL RC 195 Single Input Receiver-Controller Description The RC 195 Single lnput Receiver-Controller is a pneumatic instrument which receives one pneumatic input,
More informationPRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
More informationInstallation/ Operation Maintenance
Installation/ Operation aintenance VariTrane Pneumatic Controls arch 02 Thermostat Thermostat election and Location In general, both one- and two-pipe thermostats have a gain of 2.5 psi per degree Fahrenheit,
More informationT-4000 Series Room Thermostat Adjusting Instructions*
Pneumatic Control Manual 717.1 Room Devices Section Technical Bulletin T-4000 Issue Date 0814 T-4000 Series Room Thermostat Adjusting Instructions* The T-4000 Series Pneumatic Room Thermostats are factory
More informationModel 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationCommercial Gas Cooking Thermostats
BJWA Series Commercial Gas Thermostat A223 Commercial Gas Cooking Thermostats Designed specifically for heavy-duty commercial oven and griddle applications Hi-Temp thermostat with steel bulb and capillary
More informationWILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
More informationReplacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
More informationBristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters
July 10, 2007 - Page 1 Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters General The Bristol 5453-10G indicating pneumatic pressure controller with 624-II control unit, from Emerson
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationREGULATORS D& HD Series
Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2002 Watson McDaniel Company Ductile Iron body - HD Series Full port strainer & blowdown valve on pilot
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More informationT-4000 Series Pneumatic Room Thermostats
T-4000 Series Pneumatic Room Thermostats Pneumatic Control Manual 717.1 Room Devices Section Product Bulletin T-4000 Issue Date 1285 Features Adjustable Sensitivities and Set Points Individual Set Points
More informationAUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
More informationPOWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
More informationRheem Spare Parts Manual. Commercial gas model A631265 Exterior 265L
Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Item Part No. Description 1 221735 Foam cover 2 221914 Anode x 3 (black) 1153mm 2 221924 Anode x 3 (blue) 1153mm 3
More informationPNEUMATIC CONTROLS Selection and Description
PNEUMATIC CONTROLS Selection and Description Carnes pneumatic controlled throttling units are suitable for a standard 20 psi control system and may be supplied with pressure dependent or pressure independent
More informationInstalling a Probe. Typical Installation
for hazardous locations. Prior to any installation in a Classified Hazardous Location, verify installation methods by the Control Drawing referenced on the product s name tag 2. The Feed Through Assembly
More informationM/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners
M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...
More informationNAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
More informationProduct Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
More information167D Series Switching Valves
June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are
More informationTYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
More informationBaumann 24003 3 Way Bronze or Stainless Steel Control Valve
Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control
More informationOne Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty
One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable
More informationPRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
More informationPIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
More informationCommercial & Industrial Propane Regulators and Meters
Commercial & Industrial Propane Regulators and Meters Master Distributor for First Stage Regulators P32* Field adjustable 60 Mesh screen on inlet 1/4 FNPT 250 PSI Excellent stability P37* Patented balance
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005
CUENOD Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CELTIC RSc b R8202395-02EN - Edition 02-21/04/2005 Boilers Solar Panel 69214511 31 CELTIC
More informationMustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
More informationV47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
More informationFahrenheit or Celsius set point dials. Highly sensitive bimetal thermostatic element. Individual field adjustable sensitivity with graduated scale
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical l InstructionI TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Des escription Featur ures The TH 192 HC thermostats are proportional single
More informationElegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
More informationTECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
More informationG234X-55 Conventional Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural
More informationOEM-EP Pressure Controllers
Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable
More informationMany Products...One Source
PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K
More informationPressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
More informationIndex 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
More informationIntroduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D-193. www.usa.siemens.com/hvac
Introduction Angle/Flared/Sequence/Changeover Service D-193 In this section, you will find flared, angled, sequence and changeover valves for use in service applications. D-194 Need additional assistance?
More informationShut-off & Lockout Valves 1/4" to 1-1/2" port size
Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout
More informationKNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationCEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationWON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin 30-34 / March 2013
Bulletin 30-34 / March 2013 INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES General The information on the following pages is to provide the installer the necessary information to properly install the
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationThe Axial Flow Valve. Class 300/600. sales@elster-instromet.co.uk www.elster-instromet.com SERIES
The Axial Flow Valve SERIES Class 300/600 sales@elster-instromet.co.uk www.elster-instromet.com THE AXIAL FLOW VALVE - SERIES 300/600 A UNIQUE REGULATOR What is the Axial Flow Valve? The Axial Flow Valve
More informationBULLETIN 70.00-1 OCTOBER 2012. DeZURIK ROTARY DIAPHRAGM ACTUATORS
BULLETIN 70.00-1 OCTOBER 2012 DeZURIK ROTARY DIAPHRAGM ACTUATORS 2 2012 DeZURIK, Inc. Design & Construction DeZURIK rotary diaphragm actuators are available for use on rotary control valves including:
More informationT-5800-1 and T-5800-2 Single Input Receiver-Controllers Installation and Calibration
T-5800-1 and T-5800-2 Single Input Receiver-Controllers Installation and Calibration 24-7028- 6, Rev. A Technical Bulletin T-5800-1/-2 Issue Date 0316 The T-5800 Series Receiver- Controllers are designed
More information820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.
SIT Group 820 NOVA mv MULTIFUNCTIONAL CONTROL FOR GAS THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE PIN 3AP700/2 SINGLE-KNOB MULTIFUNCTIONAL
More informationAIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
More informationM7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
More informationPLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
More informationFUEL SYSTEM FUEL SYSTEM MERCURY OUTBOARDS FUEL FILTERS & SCREENS. 96 2012 EMEA Parts Guide FUEL FILTER INLINE FUEL FILTER INLINE FUEL FILTER
FUEL FILTERS & SCREENS INLINE FUEL FILTER FUEL SYSTEM FUEL FILTER 35-816296Q03 In line fuel filter used with 1/4 in. ID fuel line. Located under the cowling, on the outboard engine. Found in use with 1/4"
More informationNEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
More informationINSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
More informationConstantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
More informationTypical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
More informationFloat and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
More informationHOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationCoolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
More informationUNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationSeries GM. Peerless Boilers. Residential/Commercial Gas Boilers
Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler
More informationRI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationvav retrofit terminals
retrofit Redefine your comfort zone. www.titus-hvac.com energy solutions Table of Contents products Application Icons Key... 2 VAV Retrofit Terminals roducts... 3 external round duct series EXX, ECX and
More informationREGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
More informationHow To Power A Car With A Fan And A Fan (Power)
SPLIT TYPE ROO AIR CONDITIONER CEILING WALL TYPE INVERTER Indoor unit AWYZLBC AWYZLBC AWYZLBC AWYZLBC Outdoor unit AOYZLBC AOYZLBL AOYZLBC AOYZLBL CONTENTS SPECIFICATIONS................... OUTLINE AND
More informationLAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
More informationRADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS
RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
More informationType 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationIndirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
More informationCommercial Semi-Instantaneous Water Heaters
FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory
More informationVAD. Variable Area Desuperheaters
Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationElement D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
More informationREFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca
More informationMONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB
MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
More informationREMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
More informationVacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology
Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides
More information