1 CUMMINS ENGINE COMPANY, INC Basic Engine Model: KTA-G3 Curve Number: FR-62 Page No. Columbus, Indiana 4721 Engine Critical Parts List: Date: ENGINE PERFORMANCE CURVE CPL: Jan1 Displacement :.3 litre (367 in 3 ) Bore : 19 mm (6.2 in.) Stroke : 19 mm (6.2 in.) No. of Cylinders : 16 Aspiration : Turbocharged and Aftercooled Engine Speed Standby Power Limited Time Prime Power Unlimited Time Continuous Power RPM kwm BHP kwm BHP kwm BHP kwm BHP Engine Performance 1 RPM OUTPUT POWER % kwm BHP kg/ kwm h FUEL CONSUMPTION lb/ BHP h litre/ U.S. Gal/ STANDBY POWER PRIME -- LIMITED TIME RUNNING POWER PRIME -- UNLIMITED TIME RUNNING POWER CONTINUOUS POWER Litre/ 1 RPM Gross Engine Power Output - kwm CONVERSIONS: (Litres = U.S. Gal x 3.78) (kwm = BHP x.746) (U.S. Gal = Litres x.2642) (BHP = Engine kwm x 1.34) These guidelines have been formulated to ensure proper application of generator drive engines in A.C. generator set installations. Generator drive engines are not designed for and shall not be used in variable speed D.C. generator set applications. STANDBY POWER RATING Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the Standby Power rating. This rating should be applied where reliable utility power is available. A Standby rated engine should be sized for a maximum of an 8% average load factor and 2 s of operation per year. This includes less than 2 s per year at the Standby Power rating. Standby ratings should never be applied except in true emergency power outages. Negotiated power outages contracted with a utility company are not considered an emergency. PRIME POWER RATING Applicable for supplying electric power in lieu of commercially purchased power. Prime Power applications must be in the form of one of the following two categories: UNLIMITED TIME RUNNING PRIME POWER Prime Power is available for an unlimited number of s per year in a variable load application. Variable load should not exceed a 7% average of the Prime Power rating during any operating period of 2 s. The total operating time at % Prime Power shall not exceed s per year. A % overload capability is available for a period of 1 within a 12- period of operation. Total operating time at the % overload power shall not exceed 2 s per year. LIMITED TIME RUNNING PRIME POWER Limited Time Prime Power is available for a limited number of s in a non-variable load application. It is intended for use in situations where power outages are contracted, such as in utility power curtailment. Engines may be operated in parallel to the public utility up to 7 s per year at power levels never to exceed the Prime Power rating. The customer should be aware, however, that the life of any engine will be reduced by this constant high load operation. Any operation exceeding 7 s per year at the Limited Time Prime Power rating should use the Continuous Power rating. CONTINUOUS POWER RATING Applicable for supplying utility power at a constant % load for an unlimited number of s per year. No overload capability is available for this rating. Data shown above represent gross engine performance capabilities obtained and corrected in accordance with ISO-346 conditions of kpa (29. in Hg) barometric pressure [1 m (361 ft) altitude], 2 C (77 F) air inlet temperature, and relative humidity of 3% with No. 2 diesel or a fuel corresponding to ASTM D2. See reverse side for application rating guidelines. The fuel consumption data is based on No. 2 diesel fuel weight at.8 kg/litre (7.1 lbs/u.s. gal). Power output curves are based on the engine operating with fuel system, water pump and lubricating oil pump; not included are battery charging alternator, fan, optional equipment and driven components. TECHNICAL DATA DEPT. CERTIFIED WITHIN % CHIEF ENGINEER

2 CUMMINS ENGINE COMPANY, INC Basic Engine Model: KTA-G3 Curve Number: FR-62 Page No. Columbus, Indiana 4721 Engine Critical Parts List: Date: ENGINE PERFORMANCE CURVE CPL: Jan1 Displacement :.3 litre (367 in 3 ) Bore : 19 mm (6.2 in.) Stroke : 19 mm (6.2 in.) No. of Cylinders : 16 Aspiration : Turbocharged and Aftercooled Engine Speed Standby Power Limited Time Prime Power Unlimited Time Continuous Power RPM kwm BHP kwm BHP kwm BHP kwm BHP Engine Performance 18 RPM OUTPUT POWER % kwm BHP kg/ kwm h FUEL CONSUMPTION lb/ BHP h litre/ U.S. Gal/ STANDBY POWER PRIME -- LIMITED TIME RUNNING POWER PRIME -- UNLIMITED TIME RUNNING POWER CONTINUOUS POWER U.S. Gallons/ 18 RPM Gross Engine Power Output - BHP CONVERSIONS: (Litres = U.S. Gal x 3.78) (kwm = BHP x.746) (U.S. Gal = Litres x.2642) (BHP = Engine kwm x 1.34) These guidelines have been formulated to ensure proper application of generator drive engines in A.C. generator set installations. Generator drive engines are not designed for and shall not be used in variable speed D.C. generator set applications. STANDBY POWER RATING Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the Standby Power rating. This rating should be applied where reliable utility power is available. A Standby rated engine should be sized for a maximum of an 8% average load factor and 2 s of operation per year. This includes less than 2 s per year at the Standby Power rating. Standby ratings should never be applied except in true emergency power outages. Negotiated power outages contracted with a utility company are not considered an emergency. PRIME POWER RATING Applicable for supplying electric power in lieu of commercially purchased power. Prime Power applications must be in the form of one of the following two categories: UNLIMITED TIME RUNNING PRIME POWER Prime Power is available for an unlimited number of s per year in a variable load application. Variable load should not exceed a 7% average of the Prime Power rating during any operating period of 2 s. The total operating time at % Prime Power shall not exceed s per year. A % overload capability is available for a period of 1 within a 12- period of operation. Total operating time at the % overload power shall not exceed 2 s per year. LIMITED TIME RUNNING PRIME POWER Limited Time Prime Power is available for a limited number of s in a non-variable load application. It is intended for use in situations where power outages are contracted, such as in utility power curtailment. Engines may be operated in parallel to the public utility up to 7 s per year at power levels never to exceed the Prime Power rating. The customer should be aware, however, that the life of any engine will be reduced by this constant high load operation. Any operation exceeding 7 s per year at the Limited Time Prime Power rating should use the Continuous Power rating. CONTINUOUS POWER RATING Applicable for supplying utility power at a constant % load for an unlimited number of s per year. No overload capability is available for this rating. Data shown above represent gross engine performance capabilities obtained and corrected in accordance with ISO-346 conditions of kpa (29. in Hg) barometric pressure [1 m (361 ft.) altitude], 2 C (77 F) air inlet temperature, and relative humidity of 3% with No. 2 diesel or a fuel corresponding to ASTM D2. See reverse side for application rating guidelines. The fuel consumption data is based on No. 2 diesel fuel weight at.8 kg/litre (7.1 lbs/u.s. gal). Power output curves are based on the engine operating with fuel system, water pump and lubricating oil pump; not included are battery charging alternator, fan, optional equipment and driven components. TECHNICAL DATA DEPT. CERTIFIED WITHIN % CHIEF ENGINEER

3 KTA-G3 Derate 1 RPM CURVE NO : FR-62 DATE : 12Jan1 2 12/ 2 12/ 2 1 STANDBY 4/4 77/2 2 1 LIMITED TIME PRIME 4/4 77/ PRIME 12/ 4/4 77/ CONTINUOUS 12/ 4/4 77/2 Ambient Temp ºF/ºC NOTE: Derates shown are based on 1 in H 2 air intake restriction and 2 in Hg exhaust back pressure. For sustained operation above these conditions, derate by an additional % per ft (3 m) and 9% per 18 F ( C). Reference Standards: BS-14 and DIN-6271 standards are based on ISO-346.

4 Cummins Engine Company, Inc. Engine Data Sheet DATA SHEET : DS-62 ENGINE MODEL : KTA-G3 CONFIGURATION NUMBER : D28321DX2 DATE : 12Jan1 PERFORMANCE CURVE : FR-62 INSTALLATION DIAGRAM CPL NUMBER Fan to Flywheel : Engine Critical Parts List : 2227 GENERAL ENGINE DATA Type... 4-Cycle; 6 Vee; 16-Cylinder Diesel Aspiration... Turbocharged and Aftercooled Bore x Stroke... in x in (mm x mm) 6.2 x 6.2 (19 x 19) Displacement... in 3 (liter) 367 (.3) Compression Ratio : 1 Dry Weight Fan to Flywheel Engine... lb (kg) 1182 (36) Heat Exchanger Cooled Engine... lb (kg) 1226 (6) Wet Weight Fan to Flywheel Engine... lb (kg) 1248 (662) Heat Exchanger Cooled Engine... lb (kg) 138 (934) Moment of Inertia of Rotating Components with FW 69 Flywheel... lb m ft 2 (kg m 2 ) 31 (12.7) with FW 617 Flywheel... lb m ft 2 (kg m 2 ) 1 (21.7) Center of Gravity from Rear Face of Flywheel Housing (FH 624)... in (mm) 47. (126) Center of Gravity Above Crankshaft Centerline... in (mm) 11. (279) Maximum Static Loading at Rear Main Bearing... lb (kg) 2 (98) ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 4 (6) EXHAUST SYSTEM Maximum Back Standby Power... in Hg (mm Hg) 2 (1) AIR INDUCTION SYSTEM Maximum Intake Air Restriction with Dirty Filter Standby Power... in H 2 O (mm H 2 O) 2 (63) with Clean Filter Standby Power... in H 2 O (mm H 2 O) 1 (381) COOLING SYSTEM Coolant Capacity Engine Only... US gal (liter) 42. (161) Maximum Coolant Friction Head External to Engine 18 rpm... psi (kpa) 1 (3) 1 rpm... psi (kpa) (69) Maximum Static Head of Coolant Above Engine Crank Centerline... ft (m) 6 (18.3) Standard Thermostat (Modulating) Range... F ( C) 18-2 (82-93) Minimum Pressure Cap (For Cooling Systems with less than 2 m [6 ft.] Static Head)... psi (kpa) 14 (96) Maximum Top Tank Temperature for Standby / Prime Power... F ( C) 22 / 212 (4 / ) LUBRICATION SYSTEM Oil Idle Speed... psi (kpa) 2 Governed Speed... psi (kpa) - 7 (34-483) Maximum Oil Temperature... F ( C) 2 (121) Oil Capacity with OP 624 Oil Pan : High - Low... US gal (liter) 4-32 (11-121) Total System Capacity (Including Bypass Filter)... US gal (liter) 46.7 (177) Angularity of OP 624 Oil Pan Front Down... 3 Front Up... 3 Side to Side... 3 FUEL SYSTEM Type Injection System... Direct Injection Cummins PT Maximum Restriction at PT Fuel Injection Pump with Clean Fuel Filter... in Hg (mm Hg) 4. (2) with Dirty Fuel Filter... in Hg (mm Hg) 8. (23) Maximum Allowable Head on Injector Return Line (Consisting of Friction Head and Static Head)... in Hg (mm Hg) 6. (16) Maximum Fuel Flow to Injection Pump... US gph (liter / hr) 16 (62)

5 ELECTRICAL SYSTEM Cranking Motor (Heavy Duty, Positive Engagement)... volt 24 Battery Charging System, Negative Ground... ampere 3 Maximum Allowable Resistance of Cranking Circuit... ohm.2 Minimum Recommended Battery Capacity Cold F ( C) and Above... F CCA 128 Cold 32 F to F ( C to C)... F CCA 18 Cold F to 32 F (-18 C to C)... F CCA 18 COLD START CAPABILITY Minimum Ambient Temperature for Aided (with Coolant Heater) Cold Start within seconds... F ( C) () Minimum Ambient Temperature for Unaided Cold Start... F ( C) 4 (7) PERFORMANCE DATA All data is based on: Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; not included are battery charging alternator, fan, and optional driven components. Engine operating with fuel corresponding to grade No. 2-D per ASTM D97. ISO 346, Part 1, Standard Reference Conditions of: Barometric Pressure : kpa (29.3 in Hg) Air Temperature : 2 C (77 F) Altitude : 1 m (361 ft) Relative Humidity : 3% Steady State Stability Band at any Constant Load... % +/-.2 Estimated Free Field Sound Pressure Level of a Typical Generator Set; Excludes Exhaust Noise; at Rated Load and 7. m (24.6 ft); 18 rpm / 1 rpm... dba 94.6 / 92.4 Exhaust Noise at 1 m Horizontally from Centerline of Exhaust Pipe Outlet Upwards at 4 18 / 1 rpm... dba 126 / 12 STANDBY PRIME POWER POWER UNLIMITED TIME 6 hz hz 6 hz hz Governed Engine Speed... rpm Engine Idle Speed... rpm Gross Engine Power Output... BHP (kw m ) 18 (138) 164 (1227) 163 (122) 147 (97) Brake Mean Effective Pressure... psi (kpa) 26 (1827) 283 (191) 23 (162) 23 (1744) Piston Speed... ft / min (m / s) 187 (9.) 162 (7.9) 187 (9.) 162 (7.9) Friction Horsepower... HP (kw m ) 22 (168) 1 (116) 22 (168) 1 (116) Engine Water Flow at Stated Friction Head External to Engine: 4 psi Friction Head... US gpm (liter / s) 3 (33.7) 44 (27.8) 3 (33.7) 44 (27.8) Maximum Friction Head... US gpm (liter / s) 47 (29.6) 4 (2.2) 47 (29.6) 4 (2.2) Engine Data with Dry Type Exhaust Manifold Intake Air Flow... cfm (liter / s) 39 (184) 37 (1746) 37 (1746) 34 (16) Exhaust Gas Temperature... F ( C) 887 (47) 977 (2) 86 (46) 968 (2) Exhaust Gas Flow... cfm (liter / s) 9 (429) 8 (411) 84 (3964) 79 (3728) Air to Fuel Ratio... air : fuel 26. : : : : 1 Radiated Heat to Ambient... BTU / min (kw m ) (176) 8 (1) 8 (1) 73 (13) Heat Rejection to Coolant... BTU / min (kw m ) (9) 44 (77) 44 (77) 38 (68) Heat Rejection to Exhaust... BTU / min (kw m ) 3 (93) 48 (84) 47 (83) 43 (76) N.A. - Data is Not Available N/A - Not Applicable to this Engine TBD - To Be Determined ENGINE MODEL : DATA SHEET : DATE : KTA-G3 DS-62 12Jan1 CUMMINS ENGINE COMPANY, INC. Columbus, Indiana CURVE NO. : FR-62

6 KTA-G3 Derate 18 RPM CURVE NO : FR-62 DATE : 12Jan / 2 1 STANDBY 12/ 4/4 2 1 LIMITED TIME PRIME 4/4 77/2 77/ / 2 1 PRIME 12/ 4/4 77/2 2 1 CONTINUOUS 4/4 77/ NOTE: Derates shown are based on 1 in H 2 air intake restriction and 2 in Hg exhaust back pressure. For sustained operation above these conditions, derate by an additional 6% per ft (3 m) and 8% per 18 F ( C). Reference Standards: BS-14 and DIN-6271 standards are based on ISO-346.

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance

More information

@Perkins. Technical Data Series 1104A-44TG1. 64, rev/min 75, rev/min. Basic technical data.

@Perkins. Technical Data Series 1104A-44TG1. 64, rev/min 75, rev/min. Basic technical data. Technical Data Basic technical data Performance @Perkins 1100 Series 1104A-44TG1 Gen Set 64,3 kwm @ 1500 rev/min 75,5 kwm @ 1800 rev/min Number of cylinders....................................................

More information

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS 6BTA5.9 F1 FIRE PUMP ENGINE /-- SPECIFICATIONS Four Stroke Cycle, Turbocharged-Aftercooled, In-Line, 6 Cylinder Diesel Engine LISTED AGENCY RATINGS 182 HP O 1760 RPM 208 HP O 2100 RPM Bore and Stroke 4.02

More information

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET MTU 12V1600 DS660 DIESEL GENERATOR SET MTU 12V1600 DS660 400 230 V/659 kva/50 Hz/Standby Power Series 1600 MTU 12V1600 Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Industry-leading

More information

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK 99.5 kwm @ 1500 rpm

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK 99.5 kwm @ 1500 rpm Building upon Perkins proven reputation within the power generation industry, the Perkins 1100 Series range of ElectropaK engines now fit even closer to the needs of their customers. With this 1104C-44TAG2

More information

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm Marine Auxiliary Engine SPECIFICATIONS 3304B 56 bkw (75 bhp) 100 mhp @ 1200 rpm Shown with Accessory Equipment I-4, 4-Stroke-Cycle-Diesel Emissions...IMO compliant Displacement... 7.0 L (425 cu. in.) Bore...

More information

3512B bkw bhp

3512B bkw bhp Marine Engine 3512B 970-1 1-14 rpm CATERPILLAR ENGINE SPECIFICATIONS Shown with Accessory Equipment STANDARD ENGINE EQUIPMENT Air Inlet System air cleaners, regular duty; dual turbochargers, 152 mm (6

More information

C18 ACERT Fire Pump CATERPILLAR ENGINE SPECIFICATIONS FEATURES. 522 bkw/700 1500 rpm

C18 ACERT Fire Pump CATERPILLAR ENGINE SPECIFICATIONS FEATURES. 522 bkw/700 1500 rpm CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression

More information

C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm

C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression

More information

NEBRASKA OECD TRACTOR TEST 1923 SUMMARY 593 JOHN DEERE 7430 DIESEL INFINITELY VARIABLE TRANSMISSION

NEBRASKA OECD TRACTOR TEST 1923 SUMMARY 593 JOHN DEERE 7430 DIESEL INFINITELY VARIABLE TRANSMISSION NEBRASKA OECD TRACTOR TEST 1923 SUMMARY 593 JOHN DEERE 7430 DIESEL INFINITELY VARIABLE TRANSMISSION POWER TAKE-OFF PERFORMANCE Power Crank HP shaft (kw) speed Gal/hr lb/hp.hr Hp.hr/gal Mean Atmospheric

More information

NEBRASKA OECD TRACTOR TEST 2102 SUMMARY 967 JOHN DEERE 8370R DIESEL INFINITELY VARIABLE TRANSMISSION

NEBRASKA OECD TRACTOR TEST 2102 SUMMARY 967 JOHN DEERE 8370R DIESEL INFINITELY VARIABLE TRANSMISSION NEBRASKA OECD TRACTOR TEST 2102 SUMMARY 967 JOHN DEERE 8370R DIESEL INFINITELY VARIABLE TRANSMISSION POWER TAKE-OFF PERFORMANCE Power Crank Diesel D.E.F. HP shaft Consumption Consumption (kw) speed Gal/hr

More information

Diesel Generating Set

Diesel Generating Set MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V

More information

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater. Diesel Truck Engine 3126B 175-330 hp 420-860 @ 1440 rpm Peak CATERPILLAR ENGINE SPECIFICATIONS 6-Cylinder, 4-Stroke-Cycle Diesel Bore in (mm)... 4.33 (110) Stroke in (mm)... 5.0 (127) Displacement cu in

More information

3516 Industrial Engine

3516 Industrial Engine CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle Diesel Bore...170.0 mm (6.69 in) Stroke...190.0 mm (7.48 in) Displacement... 69.06 L (4,214.3 in 3 ) Aspiration...Turbocharged / Aftercooled Compression Ratio...13.0:1

More information

DIESEL GENERATOR SETS

DIESEL GENERATOR SETS DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete

More information

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical Specification. Generating Set with Waukesha engine burning natural gas Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the

More information

Section 10 Maintenance Specifications

Section 10 Maintenance Specifications Page 10-1 Section Contents Page General Engine Data...10-3 Fuel System Specifications...10-4 Lubricating Oil System Specifications...10-4 Cooling System Specifications...10-4 Air Intake System Specifications...10-5

More information

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T O R S E T GEP550 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET Complete system designed and built at ISO9001 certified facility Factory

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

Section 10 Maintenance Specifications

Section 10 Maintenance Specifications Page 10-1 Section Contents Page General Engine Data...10-3 Fuel System Specifications...10-3 Lubricating Oil System Specifications...10-4 Cooling System Specifications...10-4 Air Intake System Specifications...10-4

More information

Section 6 System Diagrams

Section 6 System Diagrams Page 6-1 Section Contents Page Overview...6-3 Flow Diagram, Fuel System...6-4 Flow Diagram, Lubricating Oil System...6-5 Flow Diagrams, Cooling System...6-9 Flow Diagrams, Air Intake System...6-11 Flow

More information

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET DIESEL SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are Tier II EPA

More information

NEBRASKA OECD TRACTOR TEST 2146 SUMMARY 1009 JOHN DEERE 6145R AUTOQUAD-PLUS DIESEL 20 SPEED

NEBRASKA OECD TRACTOR TEST 2146 SUMMARY 1009 JOHN DEERE 6145R AUTOQUAD-PLUS DIESEL 20 SPEED NEBRASKA OECD TRACTOR TEST 2146 SUMMARY 1009 JOHN DEERE 6145R AUTOQUAD-PLUS DIESEL 20 SPEED POWER TAKE-OFF PERFORMANCE Power Crank Diesel D.E.F. HP shaft Consumption Consumption (kw) speed Gal/hr lb/hp.hr

More information

NEBRASKA OECD TRACTOR TEST 2132 SUMMARY 1002 JOHN DEERE 8370RT DIESEL e23 TRANSMISSION

NEBRASKA OECD TRACTOR TEST 2132 SUMMARY 1002 JOHN DEERE 8370RT DIESEL e23 TRANSMISSION NEBRASKA OECD TRACTOR TEST 2132 SUMMARY 1002 JOHN DEERE 8370RT DIESEL e23 TRANSMISSION POWER TAKE-OFF PERFORMANCE Power Crank Diesel D.E.F. HP shaft Consumption Consumption (kw) speed Gal/hr lb/hp.hr Hp.hr/gal

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

NEBRASKA OECD TRACTOR TEST 2134 SUMMARY 1004 JOHN DEERE 9570RT DIESEL 18 SPEED

NEBRASKA OECD TRACTOR TEST 2134 SUMMARY 1004 JOHN DEERE 9570RT DIESEL 18 SPEED NEBRASKA OECD TRACTOR TEST 2134 SUMMARY 1004 JOHN DEERE 9570RT DIESEL 18 SPEED POWER TAKE-OFF PERFORMANCE Power Crank Diesel D.E.F. HP shaft Consumption Consumption (kw) speed Gal/hr lb/hp.hr Hp.hr/gal

More information

NEBRASKA OECD TRACTOR TEST 2126 SUMMARY 982 CASE IH MAGNUM 380 DIESEL CVT TRANSMISSION

NEBRASKA OECD TRACTOR TEST 2126 SUMMARY 982 CASE IH MAGNUM 380 DIESEL CVT TRANSMISSION NEBRASKA OECD TRACTOR TEST 2126 SUMMARY 982 CASE IH MAGNUM 380 DIESEL CVT TRANSMISSION POWER TAKE-OFF PERFORMANCE Power Crank Diesel D.E.F. HP shaft Consumption Consumption (kw) speed Gal/hr lb/hp.hr Hp.hr/gal

More information

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel

More information

NEBRASKA OECD TRACTOR TEST 2131 SUMMARY 1001 JOHN DEERE 8370R DIESEL e23 TRANSMISSION

NEBRASKA OECD TRACTOR TEST 2131 SUMMARY 1001 JOHN DEERE 8370R DIESEL e23 TRANSMISSION NEBRASKA OECD TRACTOR TEST 2131 SUMMARY 1001 JOHN DEERE 8370R DIESEL e23 TRANSMISSION POWER TAKE-OFF PERFORMANCE Power Crank Diesel D.E.F. HP shaft Consumption Consumption (kw) speed Gal/hr lb/hp.hr Hp.hr/gal

More information

Specifications for Volkswagen Industrial Engine

Specifications for Volkswagen Industrial Engine Volkswagen 1 industrial engine Specifications for Volkswagen Industrial Engine AFD 1.9 ltr. TDI diesel engine EURO 2 Volkswagen AG, Wolfsburg Volkswagen AG reserves the right to introduce amendments or

More information

S590 SKID-STEER LOADER SPECIFICATIONS

S590 SKID-STEER LOADER SPECIFICATIONS Loader Dimensions S590 SKID-STEER LOADER SPECIFICATIONS Dimensions are given for loader equipped with standard tires and 68 in. Construction and Industrial bucket and may vary with other bucket types.

More information

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFHC 60 Hz Diesel Generator Set Model DFHC 60 Hz 900 kw, 1125 kva Standby 818 kw, 1023 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation

More information

STANDBY GENERATOR 35 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT035-35 kw 60Hz

STANDBY GENERATOR 35 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT035-35 kw 60Hz STANDBY GENERATOR 35 kw LIQUID-COOLED GENERATOR SET Standby Power Rating Model HT035-35 kw 60Hz INCLUDES Two Line LCD Tri-lingual Digital Sync Controller Electronic Governor Closed Coolant Recovery System

More information

NEBRASKA OECD TRACTOR TEST 1893 SUMMARY 560 JOHN DEERE 7630 AUTOQUAD-PLUS DIESEL 20 SPEED

NEBRASKA OECD TRACTOR TEST 1893 SUMMARY 560 JOHN DEERE 7630 AUTOQUAD-PLUS DIESEL 20 SPEED NEBRASKA OECD TRACTOR TEST 1893 SUMMARY 560 JOHN DEERE 7630 AUTOQUAD-PLUS DIESEL 20 SPEED POWER TAKE-OFF PERFORMANCE Power Crank HP shaft (kw) speed Gal/hr lb/hp.hr Hp.hr/gal Mean Atmospheric rpm (l/h)

More information

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Standard Features 3 Cylinder Diesel Engine for maximum durability, reliability and efficiency. Brushless alternator

More information

Section 11 System Diagrams

Section 11 System Diagrams Page 11-1 Section Contents Page System Diagrams Overview...11-3 Flow Diagram, Fuel System...11-4 Flow Diagram, Lubricating Oil System...11-5 Flow Diagram, Cooling System...11-9 Flow Diagram, Air Intake

More information

Quiet Connect TM Series RS30

Quiet Connect TM Series RS30 Specification sheet Quiet Connect TM Series RS30 Features and benefits Robust product design and testing - The generator is designed to operate under extreme environmental conditions including cold weather

More information

Diesel Generator Set Model DFMB 60 Hz

Diesel Generator Set Model DFMB 60 Hz Diesel Generator Set Model DFMB 60 Hz 1500 kw, 1875 kva Standby 1250 kw, 1563 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation

More information

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption IE DIESEL FEATURES GENERATOR SET PRIME 2000 ekw 2500 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability,

More information

STANDBY 2400 ekw 3000 kva 50 Hz 1500 rpm 3300 Volts

STANDBY 2400 ekw 3000 kva 50 Hz 1500 rpm 3300 Volts DIESEL GENERATOR SET STANDBY 2400 ekw 3000 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

Section 11 - System Diagrams

Section 11 - System Diagrams Section 11 System Diagrams Page 11-1 Section 11 - System Diagrams Section Contents Page Overview...11-3 Flow Diagram, Air Intake System...11-4 Flow Diagram, Cooling System...11-5 Flow Diagram, Exhaust

More information

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T I N G S E T GEP150 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 150 kva / 120 kw 135 kva / 108 kw 165 kva / 132 kw 150 kva / 120 kw FEATURES GENERATING SET Complete system

More information

1008/F. The engine for construction equipment.

1008/F. The engine for construction equipment. 1008/F. The engine for construction equipment....... 4-31 kw at 1200-3600 min -1 These are the characteristics of the 1008/F: Watercooled 2-, 3- and 4-cylinder in-line engines. 4-cylinder 1008 engine turbocharged.

More information

CONTINUOUS 4700 ekw 5875 kva 50 Hz 1000 rpm

CONTINUOUS 4700 ekw 5875 kva 50 Hz 1000 rpm DIESEL GENERATOR SET CONTINUOUS 4700 ekw 5875 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched

More information

an EnPro Industries company POWERSolutions

an EnPro Industries company POWERSolutions an EnPro Industries company POWERSolutions Steadfast Performer, Trustworthy Reliability, and Relentless Dependability The FM/ALCO engine, a world renowned name well established as a workhorse and prime

More information

Model DFEJ 60 Hz EPA Emissions

Model DFEJ 60 Hz EPA Emissions Diesel Generator Set Model DFEJ 60 Hz EPA Emissions 450 kw, 563 kva Standby 410 kw, 513 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power

More information

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 800 ekw 1000kVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,

More information

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

The Yachtmans Choice...

The Yachtmans Choice... Ref: 1740, Nov 2015 The Yachtmans Choice... A competitive price 10 to 150 hp, engineered in the UK Advanced, compact, quiet reliable engines Easy engine replacement, with our special feet option Amazing

More information

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel. www.hatz-diesel.com

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel. www.hatz-diesel.com CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C Hatz Diesel EN www.hatz-diesel.com Exhaust gas recirculation (EGR) For years already the Hatz 4L42C has been successfully fitted with a robustly

More information

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT080-80 kw 60Hz

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT080-80 kw 60Hz STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET Standby Power Rating Model HT080-80 kw 60Hz INCLUDES Two Line LCD Tri-lingual Digital Sync Controller Electronic Governor Closed Coolant Recovery System

More information

912. The engine for construction equipment.

912. The engine for construction equipment. 912. The engine for construction equipment....... 24-82 kw at 1500-2500 min -1 These are the characteristics of the 912: Air-cooled 3-, 4-, 5-, 6-cylinder naturally aspirated in-line-engines. Direct injection.

More information

Full Line-Up of EGS-Series Generator Sets to Meet Your Requirements

Full Line-Up of EGS-Series Generator Sets to Meet Your Requirements Full LineUp of EGSSeries Generator Sets to Meet Your Requirements EGS45BS6 EGS65BS6 EGS120BS8 EGS160BS8 Open Type EGS456 EGS656 EGS1208 EGS1608 1/4 Rated Output Frequency 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz

More information

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered

More information

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) RENTAL Standby Prime Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) Shown with optional trailer FEATURES EPA TIER 4 AND CARB CERTIFIED

More information

1013 E. The engine for agricultural equipment.

1013 E. The engine for agricultural equipment. 1013 E. The engine for agricultural equipment.... -186 kw at 2300 rpm These are the characteristics of the 1013 E: Modern water-cooled 4- and 6-cylinder in-line engine Turbocharging with charge air cooling

More information

Section 11 - System Diagrams

Section 11 - System Diagrams Section 11 System Diagrams Page 11-1 Section 11 - System Diagrams Section Contents Page Overview...11-3 Flow Diagram, Fuel System...11-4 Flow Diagrams, Lubricating Oil System...11-5 Flow Diagrams, Cooling

More information

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET STANDBY 2500 ekw 3125 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw ,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted

More information

WÄRTSILÄ 50DF PRODUCT GUIDE

WÄRTSILÄ 50DF PRODUCT GUIDE WÄRTSILÄ 50DF PRODUCT GUIDE Introduction Introduction This Product Guide provides data and system proposals for the early design phase of marine engine installations. For contracted projects specific

More information

GE Marine. Clean, lean marine. GE s L250 EPA Tier 3 inline diesel engine. GE imagination at work

GE Marine. Clean, lean marine. GE s L250 EPA Tier 3 inline diesel engine. GE imagination at work GE Marine Clean, lean marine GE s L250 EPA Tier 3 inline diesel engine GE imagination at work GE s marine-class engines A history of proven performance GE Transportation has been serving the transportation

More information

9 hp Overhead Valve Engine Full-Featured Control Panel Low Oil Pressure Shutdown with Indicator Light 6.5-gal, 13-hr Fuel Tank Idlematic

9 hp Overhead Valve Engine Full-Featured Control Panel Low Oil Pressure Shutdown with Indicator Light 6.5-gal, 13-hr Fuel Tank Idlematic Pro 4000 GenSet Gasoline 4.0 kw 60 Hz Portable GenSet Onan 9 hp Overhead Valve Engine Full-Featured Control Panel Low Oil Pressure Shutdown with Indicator Light 6.5-gal, 13-hr Fuel Tank Idlematic Models

More information

Section 6 - System Diagrams

Section 6 - System Diagrams Section 6 System Diagrams Page 6-1 Section 6 - System Diagrams Section Contents Page Overview...6-3 Flow Diagram, Fuel System...6-4 Flow Diagrams, Lubricating Oil System...6-5 Flow Diagrams, Cooling System...6-8

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

INDUSTRIAL ENGINE RATINGS GUIDE

INDUSTRIAL ENGINE RATINGS GUIDE INDUSTRIAL ENGINE RATINGS GUIDE Table of Contents Highly Regulated/Lesser Regulated For purposes of this Guide, Highly Regulated refers to engines that meet stringent emission standards in effect in the

More information

Vehicular Engine Design Extra Material

Vehicular Engine Design Extra Material Vehicular Engine Design Extra Material Contents Chapter 1: The Internal Combustion Engine An Introduction... 2 Problem 1.1: Calculate Total Engine Displacement... 2 Problem 1.2: Calculate Engine Power

More information

Centrifugal Fans and Pumps are sized to meet the maximum

Centrifugal Fans and Pumps are sized to meet the maximum Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed

More information

Diesel Generator Set Model DKAF Nonroad 60 Hz

Diesel Generator Set Model DKAF Nonroad 60 Hz Diesel Generator Set Model DKAF Nonroad 60 Hz 25 kw, 31 kva Standby 23 kw, 29 kva Prime Description The Cummins Power Generation DK-series commercial generator set is a fully integrated power generation

More information

Annex-A TECHNICAL SPECIFICATION

Annex-A TECHNICAL SPECIFICATION Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery

More information

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES: Standby Generators Liquid-Cooled Gas Engine 1 of 9 INCLUDES: Two Line LCD Tri-Lingual Digital Nexus Controller Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System

More information

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 60,0/48,0 66,0/52,8 91,93 400/ ,8 60,0/48,0 66,0/52,8 95,38

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 60,0/48,0 66,0/52,8 91,93 400/ ,8 60,0/48,0 66,0/52,8 95,38 TECHNICAL SPECIFICATIONS Model: IIV60 Generator set with manual or automatic control panel. Image for guidance purposes. (400 / 230 V) ENGINE MAKE IVECO N45SM1A CONTINUOUS POWER: (PRP Prime Power norma

More information

SPECIFICATION DGK25C

SPECIFICATION DGK25C SPECIFICATION DGK25C CONTENTS CHAPTER 1: GENERAL STANDARDS & CONDITIONS 1 1. DESIGN STANDARDS 1 2. DESIGN CONDITIONS 3. FACTORY INSPECTION 4. PAINTING PROCESS CHAPTER 2: EQUIPMENT SPECIFICATIONS 2 1. OVERALL

More information

Diesel Generator Set Model DGDK 60 Hz

Diesel Generator Set Model DGDK 60 Hz Diesel Generator Set Model DGDK 60 Hz 125 kw, 156 kva Standby 113 kw, 141 kva Prime Description The Cummins Power Generation DG-series commercial generator set is a fully integrated power generation system

More information

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1 Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault

More information

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts

PRIME 480 ekw 600 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET PRIME 480 ekw 600 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

STANDBY 440 ekw 550 kva 50 Hz 1500 rpm 400 Volts

STANDBY 440 ekw 550 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 440 ekw 550 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

M52TU Introduction Overview Technical Data Crankcase Crankshaft Pistons and Connecting Rods...

M52TU Introduction Overview Technical Data Crankcase Crankshaft Pistons and Connecting Rods... Table of Contents ENGINES Subject Page M52TU................................................. 3 Introduction............................................ 4 Overview..............................................

More information

New 27 hp 2 Cylinder Liquid-Cooled Engine

New 27 hp 2 Cylinder Liquid-Cooled Engine New 27 hp 2 Cylinder Liquid-Cooled Engine Introducing the new 27 hp Liquid-Cooled Vanguard 2/LC Engine A cooler, smoother, longer running commercial engine. That s the liquid-cooled advantage of the Vanguard

More information

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered

More information

Selecting a Vertical Turbine Pump (Information required from client)

Selecting a Vertical Turbine Pump (Information required from client) Selecting a Vertical Turbine Pump (Information required from client) 1. Liquid to be pumped: (Note: If liquid is not clear water, the following must also be ascertained). a. Foreign material present in

More information

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts GAS GENERATOR SET NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts Image shown may not reflect actual package Caterpillar is leading the power generation marketplace with power solutions

More information

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

3516B Offshore Generator Set

3516B Offshore Generator Set 3516B Offshore Generator Set 1648 ekw (2060 kva) 1717 bkw (2303 bhp) 50 Hz (1500 rpm) Actual configuration may vary from displayed image CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle-Diesel Emissions...

More information

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS GAS GENERATOR SET NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS Image shown may not reflect actual package Caterpillar is leading the power generation

More information

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET STANDBY 1500 ekw 1875 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

EVERY ROUTE. ISB FOR SCHOOL BUS APPLICATIONS

EVERY ROUTE. ISB FOR SCHOOL BUS APPLICATIONS EVERY ROUTE. TM ISB FOR SCHOOL BUS APPLICATIONS SCHOOL BUS APPLICATIONS. The Cummins ISB is the perfect engine to power your school bus. Reliable, efficient and quiet, the ISB delivers the power you need

More information

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption DIESEL GENERATOR SET STANDBY 560 ekw 700 kva Caterpillar is leading the power generation market place with power solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Dynamic Gas Blending Kit for use with 3512C Generator Set

Dynamic Gas Blending Kit for use with 3512C Generator Set Dynamic Gas Blending Kit for use with 3512C Generator Set 1045 ekw (1492 kva) 1101 bkw (1476 bhp) 1200 rpm 60 Hz Image shown with optional attachments. FEATURES Dynamic Gas Blending System - Achieves up

More information

WÄRTSILÄ 34DF PRODUCT GUIDE

WÄRTSILÄ 34DF PRODUCT GUIDE WÄRTSILÄ 34DF PRODUCT GUIDE Copyright by WÄRTSILÄ FINLAND Oy All rights reserved. No part of this document may be reproduced or copied in any form or by any means (electronic, mechanical, graphic, photocopying,

More information

Spark-Ignited Generator Set Model GGFE 60 Hz

Spark-Ignited Generator Set Model GGFE 60 Hz Spark-Ignited Generator Set Model GGFE 60 Hz - 42 kw, 52.5 kva Standby 36 kw, 45 kva Prime - 47 kw, 58.8 kva, Standby 40 kw, 50 kva, Prime Description The Cummins Power Generation GG-series commercial

More information

Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1 K3 WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor

More information

US Heavy Duty Fleets - Fuel Economy

US Heavy Duty Fleets - Fuel Economy US Heavy Duty Fleets - Fuel Economy Feb. 22, 2006 Anthony Greszler Vice President Advanced Engineering VOLVO POWERTRAIN CORPORATION Drivers for FE in HD Diesel Pending oil shortage Rapid oil price increases

More information

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES XQ230 SOUND ATTENUATED DUAL VOLTAGE 50/60 Hz Arrangement shown with optional trailer FEATURES EMISSIONS EPA Tier 3 and CARB Emissions Certified for non-road mobile applications at all 60 Hz and 50 Hz ratings

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

V-MAC III Fault Assignments

V-MAC III Fault Assignments V-MAC III Fault Assignments ELECTRICAL FAULTS Stp Circuit Failure Blink Sequence 4 Engine Oil Pressure Low Voltage / Open 1 1 P 100 4 128/143 4 Engine Oil Pressure High Voltage 1 1 P 100 3 128/143 9 Barometric

More information

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 60HZ MC Series MCS600S-2 / MCS600-2 MCS600S-2/ MCS600-2 MC Series Features Reference images, the actual shall prevail Compact structure with high-strength

More information

DISPLACEMENT. DD13 Engine RV Model Liters. lb-ft Torque. Horsepower

DISPLACEMENT. DD13 Engine RV Model Liters. lb-ft Torque. Horsepower DD13 Engine RV Model 500 Horsepower 1650 lb-ft Torque DISPLACEMENT 12.8 Liters DETROIT ENGINES: DETROIT IS RECOGniZED AS AN INDUSTRY LEADER IN THE ENGINE BUSINESS. THROUGH THE YEARS, CUSTOMERS ACROSS THE

More information

HEAVY-DUTY, REDEFINED. REDEFINED.

HEAVY-DUTY, REDEFINED. REDEFINED. HEAVY-DUTY, REDEFINED. TO GET YOUR TOUGHEST JOBS DONE, you need an engine that works even harder than you do. That s why Caterpillar offers the CT13 engine for our vocational trucks. It delivers every

More information

Dodge Ram Diagnostic Trouble Codes

Dodge Ram Diagnostic Trouble Codes Dodge Ram Diagnostic Trouble Codes Updated to include 2010 6.7 Cummins DTCs P0008 ENGINE POSITION SYSTEM PERFORMANCE BANK 1 P000F FUEL SYSTEM OVER PRESSURE RELIEF VALVE ACTIVATED P0016 CRANKSHAFT/CAMSHAFT

More information