1 Welcome to our New Build Standard Construction Drawings Your plans Our Construction Drawings = Reduced costs Time saved An energy efficient build

2 Travis Perkins Travis Perkins has been supplying building materials to the trade for over 200 years. We are now one of the largest suppliers to the UK s building and construction industry with a national network of more than 600 branches. We provide more than 100,000 products to trade professionals for all aspects of new build. But we provide much more than just products: we can help you design your build with minimal thermal bridging and market-leading Y-values ; we can estimate your build with a fully costed take-off of the materials; we can assess your site; design your renewable heating system; and provide a range of testing services, from air tightness to acoustic. Services and Training D1A - Aerated Full Fill D1B - Aerated Partial Fill D1C - Aggregate Full Fill Sustainable Building Solutions (SBS) Established in 2010, Sustainable Building Solutions (SBS) is a division of Travis Perkins plc that provides help, support and expert technical assistance to the construction industry. SBS offers an integrated approach to providing solutions for your energy efficient building and renewable energy projects. We don t just sell products, we provide technical advice, specifications, services and training. D1D - Aggregate Partial Fill Appendix Working with

3 Our Standard Construction Drawings Welcome to our guide Achieving new build Regulations in the most cost effective manner is a challenge to housebuilders, and this guide is designed to help. Our 80 Standard Construction Drawings make it easy to save money for housebuilders, and to save time for architects and assessors. Using our drawings will give you outstanding Y-values for your SAP Assessment, which should reduce the amount of materials required in your build. Using these drawings should save money for any brick-andblock construction - can you afford not to? What are the issues for new build? For the first time in 2013, Building Regulations began to measure heat loss through junctions, and measured this by Y-values (also known as psi values). Many builders, architects and SAP assessors aren t familiar with psi values, let alone have a solution to minimise them; yet not planning for them will be costly. The assessment procedure for Building Regulations (known as SAP) assumes, by default, substantial amounts of heat are lost through junctions and around windows, unless the architect, SAP assessor and builder work together to find a solution. A typical property built to 2006 standards will be assumed, in SAP, to lose one third of its heat through junctions and around window openings. Our new build solution The 80 new build Standard Construction Drawings in this booklet will optimise the Y-value and U-value of your build. Better Y-values enable you to reduce other energy saving measures in the build and still pass SAP, possibly removing renewables or using less insulation. Each junction has minimal thermal bridging and therefore very low psi values. Architects using our junctions in their house designs have helped housebuilders to comply with 2013 Building Regulations with savings of up to 3,500 per build.

4 Key benefits to using the Travis Perkins Standard Construction Drawings Architects / SAP Assessors FREE to use Fits your bespoke designs Available in CAD Very low -values Make passing SAP easier Builders FREE to use Property Owners Specified product list of traditional building materials Easy to use guides for building 80 designs for all types of masonry construction Save up to 3.5k in building materials FREE to use Use less energy Lower running costs Fit and forget solution Warmer homes So what, practically, needs to happen for me to benefit from these drawings? Three basic steps will help you gain the benefits of the drawings in SAP. Turn the page to see a more detailed series of steps. An architect has to include them as the construction details in a set of new build or extension plans. A SAP assessor will need to use the Y-values for each junction in their SAP Assessment calculations. The builder will need to purchase the products listed in the details, build as specified, and sign the drawings within the construction pack for compliance. Turn the page for how to use the details... Architect SAP Assessor Builder Self Builder

5 How to use the details? Architect 1 Choose the correct details for your specification from this guide, or downloaded from tpsbs.co.uk 2 Design your build incorporating the specification from the detail 3 Consult with your SAP assessor and choose a heating option from the menu of options 4 Pass relevant construction drawings and the Appendix to your SAP assessor 5 Incorporate all relevant information in the construction pack Architect SAP Assessor 1 Use the psi values from the construction drawings as specified by the architect 2 Select the air tightness test level & apply to SAP calculation 3 Agree with architect which heating source from our menu of options 4 Pass all SAP calculations to architect and builder SAP Assessor Builder Self Builder Builder 1 Download the relevant construction drawings (tpsbs.co.uk) as per construction pack from architect 2 Using the specified build products available from Travis Perkins 3 Review specified construction drawings checklist and read instructions to understand the required build 4 Familiarise yourself with animations and technical information on tpsbs.co.uk 5 Return completed and signed checklist to SAP assessor/ architect for audit purposes

6 Why Y-values are important Y-values measure the heat loss from junctions within buildings Ski jackets provide an excellent example: You may be as warm in a thick jacket with the zip open, as you would be in a thin jacket with the zip closed. Thermal bridging allows heat to escape through the path of least resistance. Our drawings reduce the need to have thickly insulated walls, as they use a thermally modelled solution. Heat loss in buildings Within buildings the heat loss through junctions is known as 'thermal bridging' In a poorly insulated building, heat loss through thermal bridging is not significant In highly insulated walls (with low U-values ), the heat loss through junctions, where several components are assembled together, can be very significant if they are not well designed m 2 40 m 2 How much could I save? SAP 2012 Getting the right Y-values in the SAP Assessment for your new-build should be a key priority. If you don t make any plans for this, the SAP assessor will use Default Y-values With Default values, the SAP software assumes your junctions will lose as much heat as having a 3m 2 hole in your wall. This means you will need to specify much thicker insulation to compensate. Some approved details are available in the market which have slightly better Y-values. By using the Travis Perkins modelled junctions you can massively reduce your Y-values and save up to 40 per square metre in build costs. French Doors 2090mm x 1600mm Default Front door with window 2090mm x 1300mm Approved Window 1050mm x 915mm Travis Perkins Modelled

7 What you can do to influence SAP What is SAP? The Standard Assessment Procedure (SAP) is a method used by the UK Government to measure the overall energy efficiency of a property. The SAP rating is based on the energy costs associated with space heating, water heating, ventilation and lighting. The SAP rating is expressed on a scale of 1 to 100, the higher the number the lower the running costs. Key factors influencing SAP There are six key factors influencing your SAP Assessment, and we can help you decide on the best recipe for success: Factor Considerations How we can help 1 2 Size and shape of the building Location and orientation of the building More angles mean more junctions, making more potential thermal bridges South facing windows benefit from passive solar gain therefore south facing roof space can be used for solar panels Use our construction drawings to minimise the impact of thermal bridging We design, estimate and supply renewable technologies 3 U-value of the building Insulation values and thickness of the materials Our construction drawings are fully specified with the optimum material thickness 4 Y-value of the junctions Thermal bridging in junctions and around windows Our thermally modelled drawings allow your SAP Assessor to use market-leading Y-values 5 Air tightness A function of the quality of build and materials, and the thermal efficiency of windows and doors Our 'Menu of Options' helps you match your planned air tightness result with the optimum heating system. We supply air tightness products and testing services. Boiler efficiency, type of fuel and level of heating control used has a significant impact 6 Heating and lighting systems Solar panels, renewable heating systems and waste water heat recovery systems can improve SAP ratings Open fires score badly; enclosed log burners score well Underfloor heating scores well when connected to a renewable heating source Our menu of options allows you to choose either a traditional or renewable heating system, which we can design and estimate for you

8 s priceless for me when lor, P.A. Taylor Plans Menu of Options Our menu of options: Our Standard Construction Drawings should pass regulations when combined with any of the heating and air tightness solutions below: Standard Construction Details 89% efficient boiler Standard Construction Details Standard Construction Details Standard Construction Details Standard Construction Details Air Source Heat Pump Mechanical Extract Ventilation Air Permeability 50Pa 89% efficient boiler OPTION 5 Air Permeability Mechanical Ventilation 50Pa Flue Gas Heat Recovery combi boiler OPTION Flue Gas Heat Recovery Air Permeability combi boiler Pa OPTION 3 Air Permeability Waste Water 50Pa Heat Recovery OPTION kwp Solar Photovoltaic Panel Air Permeability 50Pa Underfloor Heating 6.0 OPTION 6 Standard Construction Details Valliant Ground Source Heat Pump Air Permeability 50Pa Underfloor Heating OPTION 1 3.0

9 Annotated example of a detail Travis Perkins Standard Construction Drawings Working with SBS 58.3 Related Details Aggregate Block Full Fill Cavity Suspended Ground Floor I Beam Intermediate Floor Timber Eaves Detail Habitable Roof External Wall List of components relating to the specified drawing on each page. SBS 57.3 SBS 59.3 SBS 61.3 SBS 63.3 Each drawing is part of a family of five details that cover all aspects of the build. Appendix K Appendix R Travis Perkins Ref Junction Detail Default PSI Approved PSI Ref value PSI SCD PSI E2 Other Lintels (including other steel lintels) E3 Sill * E4 Jamb This table compares * Travis Perkins Ground Floor E5 PSI values (Normal) with the Default PSI value in SAP (used in most Intermediate buildings), Floor E6 or typical Approved within PSI values a dwelling from industry bodies. Eaves Lower (insulation E11 PSI values are better. at rafter level) * *Approved PSI value Window Detail Element U-Values This is a plan view of the cavity wall to window junction. Depending on the cavity it will have a fire proof cavity closer or a standard cavity closer. This detail may be a party wall with cavity barrier, either full Notes or part fill. Wall Floor Roof Party Wall Windows Ext Doors 0.27W/m 2 k 0.12W/m 2 k 0.11W/m 2 k 0.00W/m 2 k 1.20W/m 2 k 1.80W/m 2 k DPC should be sealed to the DPM at ground floor level 30mm insulation should be installed around the perimeter of the floor, and continued up to the bottom of the plasterboard at ground floor level. As shown in detail E5 Gable wall and intermediate floor requires adequate restraint straps All insulation must be interlinked Ensure cavities are kept clean of mortar and other debris during construction Each and every component is listed with Travis Perkins product codes. D1C - Aggregate Full Fill - SBS 58.3 Check these steps to see if the build conforms to specification. Notes may differ per drawing. Certification No. EW295C Each of the four sections has a certificate to show they are accredited and registered by building control.

10 Annotated example of a detail Travis Perkins Standard Construction Drawings Working with SBS 58.3 Aggregate Block Full Fill Cavity Suspended Ground Floor I Beam Intermediate Floor Timber Eaves Detail Habitable Roof External Wall Return to: Allows a record to be made of each use of drawing. The return to section allows the user to send the form back to the authorised person. Related Details SBS 57.3 SBS 59.3 SBS 61.3 SBS 63.3 D1C - Aggregate Full Fill - SBS 58.3 SAP Compliance Check List Ref Description Date Yes No 1. Window set back from external face of brickwork by 80mm 2. Roof insulation linked to cavity insulation 3. Window sealed to cavity closer 4. Perimeter insulation 30mm thick and in contact with wall board 5. All mortar joints around IBeam fully pointed 6. All materials used are checked against the specification shown in the related details 7. Insulation installed below DPC Check list for on-site project manager to complete. 8. DPC sealed to DPM 9. All cranked vents to be positioned touching external face and insulated behind 10. All pipes to radiators sealed through plasterboard Company: Allows an inspector to sign and make sure that all guidelines and materials used have been checked off. Site: Plot: Inspector: Date: Signature:

11 Case study 1 UK National Housebuilder: Saved up to 3,500 per new build Size: National Housebuilder Type of build: Affordable housing for private sale Objective: Reduce cavity thickness from 125mm to 100mm and remove renewables Savings: 3,500 per plot / 4.11 per sq ft. How we did it Accomplishments Our National Accounts team and SBS technical team worked collaboratively with the housebuilder. The housebuilder replaced their existing construction details with the Travis Perkins Standard Construction Drawings, at no cost The housebuilder chose details with a 100mm cavity, thereby reducing build costs and increasing the volume of the living space. The SBS technical team ran SAP calculations for the amended buildings to prove the effectiveness of the revised design and ensured that all house types passed Building Regulations The SAP calculations results were so strong - as a consequence of the market-leading Y-values - that the housebuilder could remove a solar thermal system from their plans and still pass SAP, removing the cost of a solar thermal system in each build. Overall, build costs reduced by 3,500 per property / 4.11 per sq foot. Each of the 80 new build drawings from SBS has been thermally modelled, and the resultant psi values provides a significantly higher than average improvement towards SAP. Each of the drawings is fully specified using traditional building methods and techniques with products which can be sourced through Travis Perkins branches. About the solution SBS has developed a series of 80 architectural drawings which are compliant with 2013 Building Regulations for masonry build. The drawings can be adapted to any housebuilders existing masonry plans to help them maximise building performance and minimise cost. The drawings have been approved by LABC and BRE.

12 Case study 2 Independent architect: Saved up to 1,300 per plot Size: Independent architect Type of build: Three terraced houses for private sale, On Gas Grid Objective: Optimum cost and minimal time spent on design Savings: 1,300 per plot How we did it Accomplishments SBS technical team worked collaboratively with the architect. The architect used the complete package of the Travis Perkins Standard Construction Drawings for all of the terraced houses, at no cost. The architect chose Option 4 from our Menu to combine our details with a Gas boiler, an Air Tightness test result of 5.0, and Solar Photovoltaic panels on the roof. The SBS technical team advised the u-values needed to be used in the SAP and checked the calculations for architect. Travis Perkins were able to supply a full take-off of the products required for the build, including a Solar Photovoltaic system design. Compared to a similar project the architect had previously completed, our drawings enabled the architect to reduce his cavity by 50mm, half the number of PV panels, and still achieve SAP. Overall, build costs reduced by 1,300 per property. SBS has developed a series of 80 architectural drawings which are compliant with 2013 Building Regulations for masonry build. The drawings can be adapted to any architectural designs to help maximise building performance and minimise cost. The drawings have been approved by LABC and BRE. About the solution Each of the 80 new build drawings from SBS has been thermally modelled, and the resultant psi values provides a significantly higher than average improvement towards SAP. Each of the drawings is fully specified using traditional building methods and techniques with products which can be sourced through Travis Perkins branches.

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Masonry: Cavity Wall Insulation: Partial Fill Isometric cut-away view

Masonry: Cavity Wall Insulation: Partial Fill Isometric cut-away view Legend Insulation zone Blue text Air tightness barrier (note: this can also act as a vapour control layer) Guidance on thermal continuity Red text Guidance on air tightness Values used in psi calculations

More information

Masonry Cavity Wall and Plasterboard Laminate

Masonry Cavity Wall and Plasterboard Laminate Issue 1, September 2013 CI/SfB (2 -) Rn7 (M2) Masonry Cavity Wall and Plasterboard Laminate Introduction Celotex is the brand leading manufacturer of PIR insulation boards, with its range encompassing

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ Ref. No: 12/02870/FULM Contents 1. General... 2 2. Planning Condition... 2 3. Development...

More information

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

Garage conversion guidance note

Garage conversion guidance note Garage conversion guidance note Bracknell Forest Building Control POLICY GUIDANCE THE BUILDING REGULATIONS 2010 Regulation 3, Schedule 1 This Guidance Note is for the benefit of local architects, builders

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

Structural Timber Association Building Low Carbon Timber Frame Homes

Structural Timber Association Building Low Carbon Timber Frame Homes Structural Timber Association Building Low Carbon Timber Frame Homes STA what we do TRADE BODY for - Timber Frame SIPS- CLT- Glulam Engineered wood products (see www.structural timber.co.uk for more information)

More information

Building Control Guidance Note

Building Control Guidance Note Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you

More information

Topic 3 Understanding the Energy Requirements

Topic 3 Understanding the Energy Requirements Topic 3 Understanding the Energy Requirements Planning for Climate Change - Delivering Sustainable Buildings & Quality Design Learning Objectives By the end of this session, you should have a basic understanding

More information

Green Build Timber Frame. Helping you build a greener future

Green Build Timber Frame. Helping you build a greener future Timber Frame Helping you build a greener future Timber Frame Helping you build a greener future Today s homes demand a reliable, robust, high thermal performance building envelope, which drives energy-efficiency,

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 7, Northfield Road SHEFFIELD S10 1QP Dwelling type: End-terrace house Date of assessment: 3 August 2009 Date of certificate: 3 August 2009 Reference number: 8311-6628-6400-5587-2002

More information

(1) WALLS:- INSULATION IN CAVITY Ground Floor - Insulation above slab DETAIL 1.01a, 2011 AIR BARRIER - CONTINUITY THERMAL PERFORMANCE GENERAL NOTES

(1) WALLS:- INSULATION IN CAVITY Ground Floor - Insulation above slab DETAIL 1.01a, 2011 AIR BARRIER - CONTINUITY THERMAL PERFORMANCE GENERAL NOTES (1) WALLS:- INSULATION IN CAVITY Ground Floor - Insulation above slab DETAIL 1.01a, 2011 THERMAL PERFORMANCE CHECKLIST (TICK ALL) AIR BARRIER - CONTINUITY CHECKLIST (TICK ALL) Ensure partial fill insulation

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

SAP 2012 IN A NUTSHELL

SAP 2012 IN A NUTSHELL SAP 2012 IN A NUTSHELL The consultation version of the SAP 2012 methodology was published by the Department of Energy and Climate Change (DECC) on January 4th 2012. This article from Dyfrig Hughes of National

More information

STANDARD TECHNICAL DETAILS

STANDARD TECHNICAL DETAILS STANDARD TECHNICAL DETAILS CONTENTS PAGE QL-TD-01 Quinn Lite Foundation Blocks (solid floor) 1 QL-TD-02 Quinn Lite Foundation Blocks (suspended floor) 2 QL-TD-03 Quinn Lite Foundation Blocks (stone cladding

More information

Part L 2010 where to start: An introduction for house builders and designers

Part L 2010 where to start: An introduction for house builders and designers Part L 2010 where to start: An introduction for house builders and designers Acknowledgements This guide was written and published for NHBC Foundation by Richards Partington Architects www.rparchitects.co.uk

More information

Standard Junction Details (Full Fill) INDEX AHR SJB. Feb 2013 N.T.S. A 11/2014 HH-FF-22 & HH-FF-23 ADDED SJB

Standard Junction Details (Full Fill) INDEX AHR SJB. Feb 2013 N.T.S. A 11/2014 HH-FF-22 & HH-FF-23 ADDED SJB Detail Ref. HH-FF-01 HH-FF-02 HH-FF-03 HH-FF-04 HH-FF-05 HH-FF-22 HH-FF-06 HH-FF-07 HH-FF-08 HH-FF-09 HH-FF-10 HH-FF-11 HH-FF-12 HH-FF-13 HH-FF-23 HH-FF-14 HH-FF-15 HH-FF-16 HH-PW-17 HH-PW-18 HH-PW-19

More information

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer Archetype: 3250330 Archetype Description: 1965-1975, semi / end terraced dwelling, timber frame walls, oil / gas / electric warm air heating, E This archetype represents 823 dwellings, which accounts for

More information

Low Carbon Domestic Refurbishment

Low Carbon Domestic Refurbishment www.breeam.com Briefing Paper Low Carbon Domestic Refurbishment Kiruthiga Balson, Gavin Summerson and Steven Stenlund 2 BRE Global Ltd 2014 Permission is granted for this report to be distributed only

More information

Appendix 4 - Standard technical monitoring questions

Appendix 4 - Standard technical monitoring questions Appendix 4 - Standard technical monitoring questions General questions Survey company Name of surveyor completing form Name of householder Address of householder Date of installation Date of inspection

More information

Energy efficiency and the Code for Sustainable Homes

Energy efficiency and the Code for Sustainable Homes CE291 Energy efficiency and the Code for Sustainable Homes Level 4 Also available: Energy efficiency guidance for level 3 Energy efficiency guidance for levels 5 and 6 Contents 1. Introduction 3 1.1 Energy

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5 Accredited Construction Details (Scotland) 2010 For the limitation of thermal bridging and air infiltration in low and medium rise domestic buildings Introduction & Principles Issued in support of Junction

More information

thermal cavity closers

thermal cavity closers thermal cavity closers cavity closers thermal bridging solutions from Manthorpe THERMAL BRIDGE THERMAL BREAK Poorly insulated door and window reveals can lead to significant heat loss and damp issues.

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

Building Regulations L1A your guide to practical, affordable solutions.

Building Regulations L1A your guide to practical, affordable solutions. March 2011 2nd Edition More than insulation. Building Regulations L1A your guide to practical, affordable solutions. A practical insulation guide for builders and designers to meeting the new Part L 1A

More information

CavityTherm BUILT-IN CAVITY FILL INSULATION

CavityTherm BUILT-IN CAVITY FILL INSULATION Affordable Innovation 2011 May Traditional build with extra-ordinary U-values CavityTherm BUILT-IN CAVITY FILL INSULATION Achieve 0.12W/m 2 K U-value in a traditional construction without a structural

More information

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail Ecojoist Practical benefits of Ecojoist. www.eleco.com/gang-nail Gang-Nail Systems, an Eleco plc company, offer integrated solutions f the timber engineering industry which assist in reducing design, production

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 10, Northfleet Road Eccles MANCHESTER M30 7PQ Dwelling type: Semi-detached house Date of assessment: 11 February 009 Date of certificate: 1 February 009 Reference number:

More information

URSA GLASSWOOL URSA Cavity Batts

URSA GLASSWOOL URSA Cavity Batts Cavity Batts 065_Layout 1 13/07/2015 14:43 Page 1 UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk

More information

System 26 Hi+ Bi-Fold

System 26 Hi+ Bi-Fold System 26 Hi+ Bi-Fold Since 1985 Metal Technology has been defining spaces through its architectural glazing solutions and has grown to become one of the UK and Ireland s leading designers and suppliers

More information

Traditional build. CavityTherm CT/PIR. with extra-ordinary U-values. Affordable Innovation

Traditional build. CavityTherm CT/PIR. with extra-ordinary U-values. Affordable Innovation Affordable Innovation 2011 March Traditional build with extra-ordinary U-values CavityTherm CT/PIR BUILT-IN CAVITY FILL INSULATION The logical way to achieve U-values as low as 0.16 W/m 2 K from a standard

More information

Achieving Code Level Five with Concrete and Masonry

Achieving Code Level Five with Concrete and Masonry Achieving Code Level Five with Concrete and Masonry A mainstream approach for high performance, low-cost social housing. Achieving Code Level Five with Concrete and Masonry Since the introduction of the

More information

V2/0815/CWI/TD02. KORE Fill Cavity Wall Insulation. Wall Insulation Design Guide

V2/0815/CWI/TD02. KORE Fill Cavity Wall Insulation. Wall Insulation Design Guide V2/0815/CWI/TD02 Cavity Wall Insulation Wall Insulation Design Guide Bonded Bead Key Features Meets and exceeds building regulations Suitable for passive house construction Installed by insulation experts

More information

Full Fill Built-in Insulation for Traditionally Built Walls

Full Fill Built-in Insulation for Traditionally Built Walls The Affordable Solution The Practical Solution The Technical Solution The Desirable Solution Full Fill Built-in Insulation for Traditionally Built Walls Traditional wall construction to Zero Carbon targets

More information

Case Study 1 Code level 3

Case Study 1 Code level 3 Case Study 1 Code level 3 Norbury Court Staffordshire Is a development of seven three bedroom houses, one two bedroom house and one three bedroom bungalow. Design Team Contractor - LHL Development Ltd

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 0 Raleigh Drive CULLOMPTON EX15 1FZ Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Semi detached house 09

More information

Thin Joint Junction Details (full Fill) INDEX AHR SJB A 11/2014 HH-TJ-FF-22 & HH-TJ-FF-23 ADDED SJB

Thin Joint Junction Details (full Fill) INDEX AHR SJB A 11/2014 HH-TJ-FF-22 & HH-TJ-FF-23 ADDED SJB Detail Ref. HH-TJ-FF-01 HH-TJ-FF-02 HH-TJ-FF-03 HH-TJ-FF-04 HH-TJ-FF-05 HH-TJ-FF-22 HH-TJ-FF-06 HH-TJ-FF-07 HH-TJ-FF-08 HH-TJ-FF-09 HH-TJ-FF-10 HH-TJ-FF-11 HH-TJ-FF-12 HH-TJ-FF-13 HH-TJ-FF-23 HH-TJ-FF-14

More information

Guide to the safe installation of downlighters in dwellings

Guide to the safe installation of downlighters in dwellings Guide to the safe installation of downlighters in dwellings Technical guidance for designers and installers 01 Guide to the safe installation of downlighters in dwellings Technical guidance for designers

More information

Energy Performance Certificate

Energy Performance Certificate 1 Brynsyfnai, Gelli Hill, Llawhaden, NARBERTH, SA67 8DL Dwelling type: end-terrace house Reference number: 8208-7130-6829-1307-3573 Date of assessment: 07 May 2013 Type of assessment: RdSAP, existing dwelling

More information

Timber frame separation walls (party walls)

Timber frame separation walls (party walls) Appendix 8: Timber Frame Detailing This appendix illustrates with typical details major design and construction issues, which must be considered when using a timber frame approach. The details shown are

More information

Environmental drivers & opportunities:- Impacts on housing sector in UK

Environmental drivers & opportunities:- Impacts on housing sector in UK Dr. Vahik Enjily International Director Building Research Establishment (BRE) Watford, England Environmental drivers & opportunities:- Impacts on housing sector in UK Die britische Bauwirtschaft und ihre

More information

FABRIC ENERGY EFFICIENCY FOR PART L 2013

FABRIC ENERGY EFFICIENCY FOR PART L 2013 Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub

More information

A GUIDE TO WINDOW AND DOOR SELECTION

A GUIDE TO WINDOW AND DOOR SELECTION Australian window association guide series A GUIDE TO WINDOW AND DOOR SELECTION An industry guide to the selection and certification of windows and doors Background Foreword As part of its commitment to

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Rhanleta Cottage Woolsery BIDEFORD EX39 5QP Dwelling type: Detached bungalow Date of assessment: 15 July 2009 Date of certificate: 17 July 2009 Reference number: 0347-2845-6036-0991-7175

More information

Making heating systems efficient and cost-effective: boilers, heating controls & more

Making heating systems efficient and cost-effective: boilers, heating controls & more Making heating systems efficient and cost-effective: boilers, heating controls & more WHAT WE USE ENERGY FOR IN OUR HOMES DECC Energy Consumption in the UK, 2010: Table 3.3 Heating building & hot water

More information

Welcome to a warmer home. You could qualify for: www.ieservices.org.uk. Your guide to a gas supply and central heating system

Welcome to a warmer home. You could qualify for: www.ieservices.org.uk. Your guide to a gas supply and central heating system Welcome to a warmer home Your guide to a gas supply and central heating system You could qualify for: Up to 2,404 towards the cost of connecting gas to your home Up to 1,300 towards new gas central heating

More information

Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI

Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI Part L1B & What you need to know to get your building to pass. Mike Andrews DipNDEA, DipDEC, DipOCDEA, DipHI The Building Regulations Part L1B what they are, how they affect your building design, and what

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Isover Solutions Guide

Isover Solutions Guide Isover Solutions Guide Specifying Separating Masonry Cavity Wall Insulation About Saint-Gobain Isover As a world leader in designing, manufacturing and distributing building materials, Saint-Gobain is

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 68, Burlton Road CAMBRIDGE CB3 0GS Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Top floor flat 7 May 011

More information

Energy Performance Certificate

Energy Performance Certificate Trebarwith, St. Martins Lane, CREDITON, EX17 2DR Dwelling type: Detached house Reference number: 9268-3043-7264-4846-0960 Date of assessment: 16 April 2016 Type of assessment: RdSAP, existing dwelling

More information

GREEN HARMONY HOME: UP TO 90 % ENERGY SAVING!

GREEN HARMONY HOME: UP TO 90 % ENERGY SAVING! YOUR GUIDE TO BUILDING AN ENERGY EFFICIENT HOME GREEN HARMONY HOME: UP TO 90 % ENERGY SAVING! Rewable green energy Site selection Form & orientation Efficient electric devices GREEN HARMONY HOME Super

More information

HANLO The WELCOME HOME Experience.!! Simply better homes!!

HANLO The WELCOME HOME Experience.!! Simply better homes!! HANLO The WELCOME HOME Experience!! Simply better homes!! The Mission Our mission is to provide individual, sustainable and affordable homes to self builders and developers that can be built fast, efficient

More information

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. STEP-BY-STEP construction guide Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet. Welcome to our CONSERVATORY AND SUNROOM CONSTRUCTION GUIDE What is the specification

More information

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

Mayplas. The Insulation Converter. 551 Timber Frame Cavity Barrier 552 Masonry Cavity Stop Sock

Mayplas. The Insulation Converter. 551 Timber Frame Cavity Barrier 552 Masonry Cavity Stop Sock Mayplas The Insulation Converter 551 Timber Frame Cavity Barrier 552 Masonry Cavity Stop Sock Meets the requirements of:- * 2000 Approved Document B Fire Safety * 2003 Approved Document E Sound Resistance

More information

Case Studies of Successful Code for Sustainable Homes Projects

Case Studies of Successful Code for Sustainable Homes Projects Case Studies of Successful Code for Sustainable Homes Projects Sustainable Homes publish the Sustainable Homes Index For Tomorrow (SHIFT) and are a leading trainers of Code for Sustainable Homes assessors.

More information

TGD L 2011. Limiting Thermal Bridging and Air Infiltration. Acceptable Construction Details. Introduction

TGD L 2011. Limiting Thermal Bridging and Air Infiltration. Acceptable Construction Details. Introduction TGD L 2011 Limiting Thermal Bridging and Air Infiltration Acceptable Construction Details Introduction Government of Ireland 2015 1 INTRODUCTION This guide to Acceptable Construction Details (ACDs) is

More information

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS

WARMFILL CAVITY WALL INSULATION WARMFILL CAVITY WALL INSULATION FOR MASONRY CAVITY WALLS Warmfill Limited Unit 5, Port of Larne Business Park Redlands Road Larne BT40 1AX Tel: 028 9042 8260 Fax: 028 9042 7641 e-mail: sales@warmfill.com website: www.warmfill.com APPROVAL INSPECTION TESTING

More information

Information Guide New and Existing Homes a Sustainable Approach.

Information Guide New and Existing Homes a Sustainable Approach. Information Guide New and Existing Homes a Sustainable Approach. Issue 43 Guide to new and existing homes a sustainable approach This is an independent guide produced by Mitsubishi Electric to enhance

More information

Energy Performance Certificate

Energy Performance Certificate Long Valley, Ludchurch, NARBERTH, SA67 8JG Dwelling type: Detached bungalow Reference number: 2218-8071-7235-3265-4964 Date of assessment: 29 May 2015 Type of assessment: RdSAP, existing dwelling Date

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate Georgia House Stud Bradley Road Burrough Green NEWMARKET CB8 9NH Dwelling type: Detached house Date of assessment: 17 August 2011 Date of certificate: 17 August 2011 Reference

More information

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com

CI/SfB (31.9) BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE. www.iglintels.com CI/SfB (31.9) Hh2 BETTER BY DESIGN PRODUCT GUIDE COMPLETE GUIDE TO THE IG PRODUCT RANGE www.iglintels.com BETTER BY DESIGN IG produce the UK s largest range of steel lintels backed by industry leading

More information

Rainwater Harvesting

Rainwater Harvesting Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Hanson EcoHouse TM. Hanson Plc - A Global Business. Hanson Building Products. Hanson Building Products. Head Office Stewartby Bedford MK43 9LZ

Hanson EcoHouse TM. Hanson Plc - A Global Business. Hanson Building Products. Hanson Building Products. Head Office Stewartby Bedford MK43 9LZ Hanson Building Products Hanson Building Products Head Office Stewartby Bedford MK43 9LZ Tel: 08705 258258 Fax: 01234 762040 Website: www.hanson.biz/uk Email: mmc@hanson.biz Hanson Plc - A Global Business

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

Consultation Questions - Specific issues where comment is requested.

Consultation Questions - Specific issues where comment is requested. Reducing carbon dioxide emission and energy demand in new buildings - proposed amendment of the Building (Scotland) Regulations 2004 and accompanying standards and guidance within Section 6: Energy and

More information

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES WBCA 403 DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES A guide to assist those intending to install or who are involved in installing conservatories. Includes information about: conservatory and component

More information

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING BUILDING CODEACT, 1992 RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING Pursuant to clause 29(l)(b) of the Building Code Act, 1992. as amended, the Director of the Building and Development Branch

More information

Information for the Supply Chain on Green Deal Measures. Version 1

Information for the Supply Chain on Green Deal Measures. Version 1 Information for the Supply Chain on Green Deal Measures Version 1 January 2013 Contents Introduction... 3 Introduction to the links between Green Deal measures and the Green Deal assessment tools... 4

More information

Alternative Loft Escape Guide for Inner Room Terraced House Page 1 of 10

Alternative Loft Escape Guide for Inner Room Terraced House Page 1 of 10 Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET Last updated 16/11/2010 Alternative Loft Escape Guide for Inner Room Terraced House Page

More information

BUILDING SAFETY UNIT

BUILDING SAFETY UNIT POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential

More information

Modular Accommodation Solutions. Flexibility, efficiency and quality in one complete package

Modular Accommodation Solutions. Flexibility, efficiency and quality in one complete package Modular Accommodation Solutions Flexibility, efficiency and quality in one complete package Welcome Our Services Providing Your Solutions The clients who work with SEDAC Accommodation Solutions are extremely

More information

Information Guide Domestic Air Source Heat Pumps

Information Guide Domestic Air Source Heat Pumps Information Guide Domestic Air Source Heat Pumps Issue 41 Domestic Air Source Heat Pumps This is an independent guide produced by Mitsubishi Electric to enhance the knowledge of its customers and provide

More information

Accredited Construction details

Accredited Construction details Accredited Construction details June 2007 1st Edition ACCREDITED CONSTRUCTION DETAILS The Building Regulations 2000 First edition June 2007 1 Department for Communities and Local Government Eland House

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

Code for Sustainable Homes Guidelines

Code for Sustainable Homes Guidelines Canoldir Penrhos Anglesey LL65 2TS Phone: 01407 860666 Email: saps@easonline.co.uk www.easonline.co.uk Code for Sustainable Homes Guidelines A CSH rating is the responsibility of the Developer/ Architect

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

Graphic Communication. The Project Set

Graphic Communication. The Project Set Graphic Communication The Project Set Graphic Communication A building construction project requires a special set of drawings which are called a project set. These drawings are essential when a new building

More information

Differential Movement Solutions. For Timber Frame Construction

Differential Movement Solutions. For Timber Frame Construction Differential Movement Solutions For Timber Frame Construction Optimising Timber Frame Construction Timber frame provides an attractive alternative construction method for buildings of all types including

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 37, Lakeside Apartments, University of Warwick, COVENTRY, CV4 7AL Dwelling type: Groundfloor flat Date of assessment: 09 June 2009 Date of certificate: 09 June 2009

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

Proposal to achieve Code for Sustainable Homes Level 3 for a development of 7 detached dwellings

Proposal to achieve Code for Sustainable Homes Level 3 for a development of 7 detached dwellings Duchy Homes Site: Cantley Lane Doncaster Proposal to achieve Code for Sustainable Homes Level 3 for a development of 7 detached dwellings 22 nd February 2013 Leanne Brooksbank Accredited Energy & Code

More information

Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP)

Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP) Introduction to DEAP for Professionals Introduction to DEAP for Professionals 1 DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP) 2 Introduction to DEAP for Professionals Introduction to DEAP for Professionals

More information

Building fabric performance and the code for sustainable homes

Building fabric performance and the code for sustainable homes More than insulation. Building fabric performance and the code for sustainable homes Insulation for performance UK 2009 2nd Edition www.xtratherm.com More than insulation. Xtratherm Innovation - delivering

More information

Appendix S : Reduced Data SAP for existing dwellings

Appendix S : Reduced Data SAP for existing dwellings Appendix S : Reduced Data SAP for existing dwellings Reduced Data SAP has been developed by government for use in existing dwellings based on a site survey of the property, when the complete data set for

More information

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to: PASSIVE Solar Design Solar Homes Catch the Sun Are you planning a new house? Discover how you can apply solar architecture principles to: keep your heating bills to a minimum enjoy the comfort of a warm

More information

Rosslare Case Study Passive House Cost Analysis. Seamus Mullins Quantity Surveyor Michael Bennett Group

Rosslare Case Study Passive House Cost Analysis. Seamus Mullins Quantity Surveyor Michael Bennett Group Rosslare Case Study Passive House Cost Analysis Seamus Mullins Quantity Surveyor Michael Bennett Group 2 South Elevation North Elevation 3 West Elevation East Elevation 4 Ground Floor Plan 5 First Floor

More information

Module 3.8. Window U-value

Module 3.8. Window U-value Module 3.8 Window U-value Learning Outcomes On successful completion of this module learners will be able to - Describe the concept of U-values and alternative energy rating system for windows. 2 Calculation

More information

Extra. March 2014 Issue 13. Approved Document Part L 2013: special edition Technical INFORMATION AND SUPPORT. In this issue:

Extra. March 2014 Issue 13. Approved Document Part L 2013: special edition Technical INFORMATION AND SUPPORT. In this issue: Approved Document Part L 2013: special edition Technical Extra March 2014 Issue 13 In this issue: regulation and compliance Introduction 2 Key changes and transitional provisions 2 Fabric energy efficiency

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information