RoHS compliant. Clean Air Filter. Hollow Fiber Element. Series SFD. Nominal filtration rating: 0.01 µm (filtration efficiency 99.

Size: px
Start display at page:

Download "RoHS compliant. Clean Air Filter. Hollow Fiber Element. Series SFD. Nominal filtration rating: 0.01 µm (filtration efficiency 99."

Transcription

1 Clean Air Filter Series SFD Hollow Fiber Element Nominal filtration rating: 0.0 µm (filtration efficiency 99.99%) RoHS Initial pressure drop: 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow) Maximum operating pressure:.0 MPa (at 0 C) SFD00 Up to 00 L/min(ANR) SFD00 Up to 500 L/min(ANR) SFD0/0 Made to Order Up to 00 L/min(ANR) HAA HAW AT IDF IDU IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD Restriction of Hazardous Substances RoHS compliant 95

2 Clear resin case Easy to confirm a dirty element. Polycarbonated material is resistant to alcohol-based cleaning solutions. Element replaceable (Cartridge type) Replaceable hollow fiber elements Metal Case Type Piping variation Clean One-touch fittings Female thread Stainless steel or aluminum cases are available. Metal case suitable for an atmosphere exposed to organic solvents and chemicals (Fluids: Air and (Nitrogen)) SFD00 SFD00 SFD0 SFD0 Made to Order Pages 303 and 304 Type Disposable type (non-replaceable element) Cartridge type (replaceable element) Flow rate L/min (ANR) (at inlet pressure 0.7 MPa) One-touch fitting Up to 60 ø4 Up to 80 ø6 Up to 00 ø8 Up to 300 ø8 Up to 400 ø0 Up to 500 ø Up to 00 Rc /4, G /4 Rc /4, G /4 Female thread NPT /4 NPT /4 Rc /4, G /4, NPT /4 Case material Fluid Nominal filtration rating Resin Resin Air (Nitrogen) 0.0 µm (filtration efficiency: 99.99%) Note) Aluminum Stainless steel Initial pressure drop Maximum operating pressure (at 0 C) Operating temperature 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow).0 MPa (in case of nitrogen: 0.99 MPa) 5 to 45 C Note) The clean air filter is designed for the filtration of solid objects. It is not suitable for the separation of water and oil. 96

3 Integrated production in a clean environment Under a clean environment, all components have undergone ultrasonic cleaning. Assembly, inspection and antistatic double packaging processes are conducted in an integrated production system. Assembly environment Application Examples Clean blow Clean room : Class M5.5 (ISO class 7) Clean bench : Class M3.5 (ISO class 5) Blow of ionizer Fed. Std. 09E ( ): based on ISO HAA HAW AT IDF IDU IDFA IDFB IDH ID When blowing, take care not to entrain ambient air which could contaminate the workpieces. Circuit Examples Air source Air tank After-cooler Main line filter Refrigerated air dryer Mist separator Heatless air dryer or Membrane air dryer Micro mist separator Super mist separator Odor removal filter Substitution of chamber Fluid pumping, etc. Fluid Clean blow Pumping the cleaning solvents Air micro meter Static paint IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF The equipment mounted to the outlet side of SFD should be cleaned by flushing and have the same level of cleanliness as SFD. Paint + SFD LLB Hollow fiber membrane The hollow fiber membrane has a porous construction with numerous fine holes on a straw type fiber membrane wall. The hollow fiber membrane filter traps and filtrates the impurities from the compressed air through the overlapping layered fine holes. AD GD Clean Air (Image) Filter Impurities (Image) 97

4 Model Selection Select the model by using the following procedures involving the inlet pressure and the maximum flow rate. [Example] Inlet pressure: 0.6 MPa Maximum flow rate: 00 L/min (ANR). Obtain the intersection A for the inlet pressure and the maximum flow rate by using the maximum flow rate chart.. If the obtained intersection A is above the maximum flow rate line, the SFD00-C, - 0, -C0, or -C08 are selected. Maximum Flow Rate 000 SFD00-C, - 0 Flow rate (L/min(ANR)) 00 SFD00-C08 SFD00-C0 SFD00-C08, - 0 A SFD00-04 SFD Pressure (MPa) 98

5 Clean Air Filter Series SFD RoHS Max. operating pressure (MPa) Clean air filter Symbol Relationship between Operating Temperature and Max. Operating Pressure Operating temperature ( C) How to Order SFD 0 0 C08 Size Max. flow rate 00 L/min (ANR) 500 L/min (ANR) Case material Symbol Material 0 Resin Aluminum Stainless steel Symbol and are made to order. For details, refer to page 303. Specifications Model Option Symbol Nil B Option None (SFD00 only) The brackets are provided with the SFD00 series as a standard product. (Nil) Symbol Connection size Note C04 C06 C08 C0 C 0 N0 F0 Fluid Air flow capacity Nominal filtration rating Note ) Operating pressure range Note ) Operating temperature Initial pressure drop Element proof differential pressure Note 3) Proof pressure Element service life ø4 ø6 ø8 ø0 ø Clean One-touch fittings (Series KP) Rc /4 NPT /4 G /4 SFD00 only SFD00/00 SFD00 only Female thread SFD00/00 Different diameters for IN and OUT ports are Made to Order. For details, refer to page 304. SFD0 One-touch fittings ø4, ø6, ø8 Rc, NPT, G /4 Air (Nitrogen) Up to 00 L/min (ANR) SFD0 One-touch fittings ø8, ø0, ø Rc, NPT, G /4 Air (Nitrogen) Up to 500 L/min (ANR) 0.0 µm (99.99%) 00 kpa to.0 MPa (in case of nitrogen: 0.99 MPa) 5 to 45 C 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow) 0.5 MPa.5 MPa year, or when the pressure drop reaches 0. MPa. Note ) Measured under SMC s specified conditions. Note ) The maximum operating pressure varies depending on temperature. Refer to the graph that shows the relationship between operating temperature and maximum operating pressure on the left. Note 3) This means that the element does not break at 0.5 MPa. See Specific Product Precautions. Model Rated flow (L/min (ANR)) Note ) Weight ø4 (One-touch fittings) g SFD00 ø6 (One-touch fittings) g ø8 (One-touch fittings) g Rc, NPT, G / g SFD0 Note ) Rc, NPT, G / g SFD0 Note ) Rc, NPT, G / g ø8 (One-touch fittings) g SFD00 ø0 (One-touch fittings) g ø (One-touch fittings) g Rc, NPT, G / g Note ) The maximum flow rate when the inlet pressure is 0.7 MPa. Note ) SFD0 and SFD0 are produced upon receipt of order. 99 HAA HAW AT IDF IDU IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD

6 Flow Characteristics SFD00-C SFD00-C MPa 0.3 MPa 0.5 MPa 0.7 MPa 0. MPa 0.3 MPa 0.5 MPa 0.7 MPa Pressure drop (MPa) Max. flow rate line 0.9 MPa Pressure drop (MPa) Max. flow rate line 0.9 MPa Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) SFD00-C MPa 0.3 MPa 0.5 MPa 0.7 MPa SFD00-C MPa 0.3 MPa 0.5 MPa 0.7 MPa Pressure drop (MPa) Max. flow rate line 0.9 MPa Pressure drop (MPa) Max. flow rate line 0.9 MPa Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) SFD00-C08, -0, -N0, -F MPa 0.3 MPa 0.5 MPa 0.7 MPa SFD00-C, -0, -N0, -F MPa 0.3 MPa 0.5 MPa 0.7 MPa Pressure drop (MPa) Max. flow rate line 0.9 MPa Pressure drop (MPa) Max. flow rate line 0.9 MPa Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 300

7 Clean Air Filter Series SFD Construction SFD00-C t r q w e SFD00-0 r q w e Component Parts No. Description Material Note Element Cover O-ring Cassette PC, Polyolefin, PU, PET, ABS PBT PBT H-NBR PP, EPDM, Stainless steel Replacement Parts Material set SFD-BR00 No. Description Note With countersunk head screws (M3) Component Parts No. Description Material Note 3 4 Element Cover O-ring PC, Polyolefin, PU, PET, ABS PBT PBT H-NBR Replacement Parts Material set SFD-BR00 No. Description Note With countersunk head screws (M3) HAA HAW AT IDF IDU IDFA IDFB IDH ID IDG IDK AMG AFF SFD00-C o! r y q i w e Component Parts No. Description Material Note 3 Element Cover Fitting body PC, Polyolefin, PU Aluminum alloy PBT AM AMD AMH 4 5 Cassette PP, EPDM, Stainless steel AME 6 7 O-ring A O-ring B H-NBR H-NBR AMF 8 9 Rod cover Tie-rod ZFC t u!0 0 Cap nut Plain washer Replacement Parts No. Description Material Note SF SFD Element set SFD-EL00 With 3 O-rings LLB AD SFD00-0 Component Parts No. Description Material Note GD!0 i t q u w e 3 Element Cover Fitting body PC, Polyolefin, PU Aluminum alloy 4 5 O-ring A H-NBR 6 O-ring B H-NBR 7 Rod cover 8 Tie-rod 9 Cap nut 0 Plain washer r y o Replacement Parts No. Description Material Note Element set SFD-EL00 With 3 O-rings 30

8 Dimensions SFD00-C SMC ø SFD00-C Dimensions Model A C04 4 SFD00- C06 6 C08 8 B B 7 7 Applicable tubing O.D. øa mounting dimensions 4.8 SFD ø3 Hole shape for bracket mounting SMC ø Use a countersunk head screw (M3) for bracket mounting. SFD00-C SMC SFD00-C Dimensions Model A B SFD00- C08 C0 C mounting dimensions SFD00-0 SMC B 36 Applicable tubing O.D. øa 4 x x

9 Made to Order Specifications Contact us for detailed specifications, delivery and prices. Metal Case Clean air filter Symbol q SFD 0 0 Size Max. flow rate 00 L/min (ANR) The SFD is not applicable. Construction SFD0-0 Case material Symbol Material Aluminum Stainless steel e r Symbol 0 N0 F0 Component Parts No. Description Material Note 3 4 Case Cover Element O-ring Aluminum alloy Aluminum alloy PC, Polyolefin, PU, PET, ABS FKM w Connection size Rc /4 NPT /4 G /4 The metal case is not available with a clean One-touch fitting. The bracket is provided as a standard product. Replacement Parts No. Description Part no. Note Element set SFD-EL0 SFD-BR0 With O-ring Material: Stainless steel 304 Dimensions SFD0-0 SFD0-0 Metal case suitable for an atmosphere exposed to organic solvents and chemicals Specifications The specifications are the same as the standard product. Refer to Specifications on page 99. Flow Characteristics The flow characteristics are the same as the SFD00-0. Refer to Flow Characteristics on page 300. q e r t w Component Parts No. Description Material Note Case Cover Element Hex. socket head set screw O-ring PC, Polyolefin, PU, PET, ABS FKM Replacement Parts No. Description Part no. Note Element set SFD-EL0 SFD-BR0 With O-ring Material: Stainless steel 304 SFD0-0 HAA HAW AT IDF IDU IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD ø4 ø x ø4.5 3 x ø

10 Made to Order Specifications Contact us for detailed specifications, delivery and prices. Different Diameters for IN and OUT Ports Symbol Clean air filter Size Max. flow rate 00 L/min (ANR) 500 L/min (ANR) SFD 00 C04 C06 Case material Symbol Material 0 Resin Option Symbol Option Nil None B (SFD00 only) The brackets are provided with the SFD00 series as a standard product. (Nil) IN port size IN side connection symbol IN side Connection size connection symbol C04 C06 C08 C0 C 0 N0 F0 ø4 ø6 ø8 ø0 ø Clean One-touch fittings (Series KP) Rc /4 NPT /4 G /4 SFD00 Different Diameter Combinations OUT port size C04 C06 C08 0 N0 F0 C04 C06 C08 0 N0 F0 The symbol stands for unavailable combination. Dimensions SFD00 different diameters OUT side connection symbol OUT side Connection size connection symbol C04 C06 C08 C0 C 0 N0 F0 IN/OUT combination is the below table. IN port size ø4 ø6 ø8 ø0 ø Clean One-touch fittings (Series KP) Rc /4 NPT /4 G /4 SFD00 Different Diameter Combinations OUT port size C08 C0 C 0 N0 F0 C08 C0 C 0 N0 F0 The symbol stands for unavailable combination. Specifications The specifications are the same as the standard models. Refer to Specifications on page 99. Flow Characteristics When the IN and OUT ports have different diameters, the flow characteristics will be those of the port with the smaller diameter. Refer to Flow Characteristics for the smaller diameter from the chart of standard product on page 300. Construction SFD00 different diameters The construction and materials are the same as the standard product. Refer to Construction on page 30. One-touch fitting dimensions(a, B) ø4 q w One-touch fitting dimensions(a, B) ø8 q w 4.5 SMC 5.5 ø6 4.5 Basic dimension 7 Fitting dimension A Fitting dimension B ø0 5.5 Fitting dimension A Basic dimension 4.5 Fitting dimension B ø8 ø Model 304 q C04 (C06) C04 ( 0) C06 (C08) C06 ( 0) C08 ( 0) w C06 (C04) 0 (C04) C08 (C06) 0 (C06) 0 (C08) Total length 8 (A B) 76.5 (7 + A) 8.5 (A B) 76.5 (7 + A) 77 (7 + A) Model SFD00- SFD00- q C08 (C0) C08 ( 0) C0 (C) C0 ( 0) C ( 0) w C0 (C08) 0 (C08) C (C0) 0 (C0) 0 (C) Total length 5.5 (A B) 0 (4.5 + A) 5.5 (A B) 0 (4.5 + A) 0 (4.5 + A)

11 Related Products <Pre-filters for Series SFD > Mist Separator Series AM Refer to pages 0 to 08 for details. Series AM Model Rated flow (L/min (ANR)) (Nominal size B) AM50C AM50C /8, /4 /4, 3/8 Specifications Fluid Compressed air Max. operating pressure.0 MPa Min. operating pressure Note) 0.05 MPa Proof pressure.5 MPa Ambient temperature 5 to 60 C Nominal filtration rating 0.3 µm (Filtering efficiency 99.9%) Note) With auto drain: 0. MPa (N.O. type), 0.5 MPa (N.C. type) HAA HAW AT IDF IDU IDFA IDFB IDH Micro Mist Separator Series AMD Series AMD Model AMD50C AMD50C Rated flow (L/min (ANR)) (Nominal size B) Super Mist Separator Series AME /8, /4 /4, 3/8 Refer to pages 09 to 7 for details. Specifications Fluid Compressed air Max. operating pressure.0 MPa Min. operating pressure Note) 0.05 MPa Proof pressure.5 MPa Ambient temperature 5 to 60 C Nominal filtration rating 0.0 µm (Filtering efficiency 99.9%) Note) With auto drain: 0. MPa (N.O. type), 0.5 MPa (N.C. type) Refer to pages 7 to 34 for details. ID IDG IDK AMG AFF AM AMD AMH AME Series AME Model AME50C Rated flow (L/min (ANR)) 00 (Nominal size B) /8, /4 AME50C 500 /4, 3/8 Specifications Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient temperature Nominal filtration rating Compressed air.0 MPa 0.05 MPa.5 MPa 5 to 60 C 0.0 µm (Filtering efficiency 99.9%) AMF ZFC SF SFD LLB AD Odor Removal Filter Series AMF Refer to pages 35 to 43 for details. GD Series AMF Model AMF50C AMF50C Specifications Fluid Compressed air Rated flow (L/min (ANR)) Max. operating pressure.0 MPa (Nominal size B) /8, /4 /4, 3/8 Min. operating pressure Proof pressure 0.05 MPa.5 MPa Ambient temperature 5 to 60 C Nominal filtration rating 0.0 µm (Filtering efficiency 99.9%) 305

12 Related Products Ionizer/Bar type Series IZS40/4/4 Refer to Best Pneumatics No. 6 for details. Potential amplitude is reduced with Dual AC type. 5 V or less (Installation height: 300 mm) Rapid elimination of static electricity by a feedback sensor Reduction of adjustment and maintenance labor by auto balance sensor Simple operation: Can be controlled by powering the ionizer ON. (Standard type) Setting ionizer with remote controller Transition wiring may be used. High speed static electricity elimination cartridges and energy saving static electricity elimination cartridges are available. Series IZS4 IZS4 IZS40 Type Dual AC type Feedback sensor type Standard type Ion generation method Ion balance Corona discharge type ±30V Clean Regulator Series SRH/SRP Refer to pages 757 to 777 for details. Stainless steel regulator controlled for contamination Series SRH Series SRP Series SRH Series SRH3000 SRH4000 Series SRP Series SRP000 Rc /8 /4 3/8 / 9/6-8UNF 7/8-4UNF Rc M5 /8 Clean Gas Filter Series SF Refer to pages 73 to 94 for details. Nominal filtration rating 0.0 µm Series SFA Series SFB Series SFC Cartridge Type Series 00 SFA SFB00 Series SFB300 SFC00 Type Disc Straight Disposable Type Type Straight Multiple disc Main material Thread Element Housing Seal type M5 /4 PTFE + Stainless Rc Fluororubber Polyester steel 36 NPT PTFE (Electropolishing) UOJ TSJ + (FPM) PFA Main material Thread Element Housing Seal type /4 3/8 PTFE + Stainless Rc PFA steel 36 TSJ PTFE (Electropolishing) O-ring + URJ PVDF PTFE 306

13 Specific Product Precautions Be sure to read before handling. Refer to front matter 43 for Safety Instructions and pages 6 to 8 for Air Preparation Equipment Precautions. Warning Selection. Thoroughly and carefully confirm the purpose of use, required specifications and operating conditions (fluid, pressure, flow rate, nominal filtration rating and environment) then select a model within the specifications.. The product is not certified under the High Pressure Gas Safety law, so for nitrogen, its maximum operating pressure will be 0.99 MPa (gauge pressure). 3. Contact us beforehand if the product will be used in an application such as a caisson shield, breathing, food and/or medical treatment that affects the human body directly or indirectly. 4. If the compressed air includes ozone, do not use it since it may damage the product or cause malfunction. When it includes ozone, use a clean gas filter (SFA/B/C). Warning Mounting. Instruction manual Mount the product after reading and understanding the instruction manual. Keep it in a location where it can easily be found.. Flushing Flush the piping line when the filter is used for the first time or has been replaced. In the event of connecting such as piping, flush (air blow) when using this product for the first time or replacing its elements in order to reduce the affect of the dust generated from the connection, etc. Flushing the line is also required to eliminate contamination resulting from the piping line installation. Therefore, be sure to flush the line before actually running the system. Fix all mounting parts for use. 3. Use fittings with resin threads for the connection of fittings to the IN and OUT ports. Using fittings with metal threads could damage the IN and OUT ports. 4. Connect tubing to the IN and OUT One-touch fittings in accordance with the precautions for One-touch fittings. Caution. Connect the piping in accordance with the flow direction marked on the case. If connected in reverse, the element could break.. The mounting orientation does not affect the performance, but if excessive force is applied to the SFD00 series, the body may become disconnected from the bracket. Therefore, take particular care about the mounting orientation. Warning Caution on Installation. The material of the element is polycarbonate. The material is resistant to wiping with alcohol, but is not suitable for atmospheres or places with organic solvents, chemicals, cutting oils, synthetic oils, ester base compressor oils, alkalis or thread locking agents. Caution 307 HAA HAW AT IDF IDU IDFA IDFB. If the pressure difference (pressure drop) between the inlet and the outlet exceeds 0. IDH MPa, it can cause damage to the product.. Do not install the product in a place where it ID can be affected by a pulsation (including IDG surge pressure) of over 0. MPa. 3. Use caution regarding the particles that may IDK be emitted from the outlet side of a pneumatic equipment. AMG Installation of a pneumatic equipment on the outlet side can deteriorate the cleanliness because a particle will be AFF generated from the equipment. The mounting position of the pneumatic equipment needs to be considered. AM 4. Set the air flow capacity with an initial AMD pressure drop of 0.03 MPa or less. If the initial pressure drop is set to be high, its AMH service life will be shorten due to clogging. 5. Determine the product by the maximum AME consumption flow rate. When using compressed air for an air blow application, AMF calculate the maximum volume of air that will be consumed before selecting the SFD series product size. ZFC 6. Generally, the following pollutant particles are contained in compressed air. SF [Pollutant particle substances contained in the compressed air] SFD Moisture (drainage) Dusts and particles which are in the surrounding air LLB Deteriorated oil which is discharged from the compressor Solid foreign matter such as rust and/or oil in the piping AD ) The SFD series is not compatible with compressed air which contains fluids such as water and/or oil. GD ) Install a dryer (IDF, IDG, ID series), mist separator (AM series), micro mist separator (AMD series), super mist separator (AME series), or odor removal filter (AMF series), etc., for the source of the air for the SFD series. 7. Using with a flow-rate much higher than its specification could lead to exceeding the differential pressure the product can resist. Use the product within its specifications. Also, take care about the replacement period of the product, taking into consideration that the differential pressure of the filter will increase over time.

14 Specific Product Precautions Be sure to read before handling. Refer to front matter 43 for Safety Instructions and pages 6 to 8 for Air Preparation Equipment Precautions. Caution Piping. Unpacking the sealed package Since the filter is sealed in an antistatic double bag, the inner package should be unpacked in a clean atmosphere (such as a clean room).. Apply a wrench to chamfered flats or hexagon portion on the IN side or the OUT side to prevent the housing from rotating. 3. Always tighten threads with the proper tightening torque. When attaching fittings to the product, tighten with the proper tightening torque shown below. Material Resin Metal 4. Check the arrow mark on the case which shows the flow direction to connect the IN and OUT ports correctly. If connected in reverse, the element could break. Warning Tightening torque (N m) to 3 to 4 Maintenance. Follow the maintenance procedures in the instruction manual. If handled incorrectly equipment or device can be damaged or cause a malfunction.. When removing the product, exhaust the air and ensure the air is released to atmosphere before removing it. 3. When the element comes to the end of its life, immediately replace it with a new filter or replacement element (cartridge type). Service life of element The service life of the element ends when either of the following two conditions occurs. ) After year of usage has elapsed. ) When the pressure drop reaches 0. MPa even though the operating period has been less than year. Warning Operating Environment. Do not operate under the conditions listed below due to a risk of malfunction. In locations having corrosive gases, organic solvents, and chemical solutions, or in locations in which these elements are likely to adhere to the equipment. In locations in which salt water, water, or water vapor could come in contact with the equipment. In locations that are exposed to direct sunlight. (Shield the equipment from sunlight to prevent its resin material from ultraviolet ray degradation or overheating.) In locations that have a heat source and poor ventilation. (Shield the equipment from heat sources to protect it from softening degradation due to radiated heat.) In locations that are exposed to shocks and vibrations. In locations with high humidity or a large amounts of dust.. When the product is used for blowing, use caution to prevent the work from being damaged by entrained air from the surrounding area. When the compressed air is used for air blow, the exhausted air from the blow nozzle may have taken in airborne foreign matter (such as solid particle, fluid particle) from the surround air. The foreign matter will be sprayed on the work, and the airborne foreign matter may adhere to it. Therefore, use caution for the surrounding environment. Caution Other Tube Brands. When tubing of brands other than SMC s are used, verify that the tubing O.D. satisfies the following accuracy; ) Polyolefin tube: Within ±0. mm ) Polyurethane tubing: Within +0.5 mm, within 0. mm 3) Nylon tubing: Within ±0. mm 4) Soft nylon tubing: Within ±0. mm Do not use tubing which does not meet these outside diameter tolerances. It may not be possible to connect them, or they may cause other trouble, such as air leakage or the tube pulling out after connection. The recommended tube for the clean fitting is polyolefin tube. Other tubes can satisfy the performance in terms of leakage, tensile strength, etc., but impair the cleanliness. Note this point for use. 308

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

Wear Resistant Tubing

Wear Resistant Tubing Wear Resistant Tubing 1/ brasion: pprox. (Compared with SMC polyurethane tubing TU series) 3 6-color variations Description Wear resistant tubing TUZ series Polyurethane tubing TU series Green RoHS Maximum

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator CAT.ES120-4 A Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel regulator Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS Oil Free Scroll Compressors are constantly evolving ANEST IWATA was the first manufacturer to introduce Oil Free Scroll Compressors in 1991 and has kept

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

Assembly and Installation Procedures

Assembly and Installation Procedures Assembly and Installation Procedures for Pall Pharmaceutical Grade Capsule Assemblies 1. Introduction The following procedures must be followed for the installation of Pall pharmaceutical grade capsule

More information

NITROUS TRANSFER PUMP INSTRUCTIONS

NITROUS TRANSFER PUMP INSTRUCTIONS NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1 Serial No. H-V066-E-2 Wafer Check Valve User s Manual Contents (1) Be sure to read the following description of our product warranty 1 (2) General operating instructions 2 (3) General instructions for

More information

Series 30000 Hose Reels

Series 30000 Hose Reels Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are

More information

kymanual or Automatic - it s your Choice

kymanual or Automatic - it s your Choice . kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below: Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees

More information

Series M Applicable Tubing: ø2 Connection Thread: M3, M5

Series M Applicable Tubing: ø2 Connection Thread: M3, M5 iniature Fittings Series pplicable Tubing: ø2 onnection Thread:, RoHS ade to Order (Refer to page for details.) pplicable O.D. x I.D.: ø2 x ø.2 onnection thread: / One-touch fitting size: ø.2 / ø Tubing

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Stainless Steel Valves For the Sanitary Industries

Stainless Steel Valves For the Sanitary Industries www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves

More information

PET-10 INSTRUCTION MANUAL PRESSURE TANK

PET-10 INSTRUCTION MANUAL PRESSURE TANK INSTRUCTION MANUAL PRESSURE TANK PET-10 This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Equipment in this manual is exclusively for painting purposes. Do not use for other purposes. The operator

More information

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling JC Carter LLC LNG Couplings USER MANUAL 10 GPM Small Single Line Cryogenic Coupling Models 50E722 Nozzle and 50E721 Receptacle User s Manual and Installation Guide! Warning: Read the User s Manual and

More information

Radiant Temperature Sensor TY7321

Radiant Temperature Sensor TY7321 AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1 No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------

More information

SureSite Magnetic Liquid Level Indicator

SureSite Magnetic Liquid Level Indicator SureSite Magnetic Liquid Level Indicator Instruction Bulletin No. 177664-1 (Rev. E) Section 1: Weldments Thank you for purchasing the GEMS SureSite Magnetic Level Indicator. Please read this document prior

More information

SMD Rework Station TABLE OF CONTENTS

SMD Rework Station TABLE OF CONTENTS SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating

More information

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

tire inflator with pressure gauge

tire inflator with pressure gauge tire inflator with pressure gauge Model 95583 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration

More information

Compressed Air Filters

Compressed Air Filters Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

ALMATEC Series CX CX 10 CX 130

ALMATEC Series CX CX 10 CX 130 ALMATEC Series CX CX 10 CX 130 Operating and Installation Instructions ought to be studied before installing the pump The ALMATEC Maschinenbau GmbH is certified as a modern, quality-orientated enterprise

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Self Purging Liquid Trap (SPLT ) User s Manual

Self Purging Liquid Trap (SPLT ) User s Manual Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High

More information

Series 510 Submersible Level Transmitters

Series 510 Submersible Level Transmitters Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable

More information

In-Line Filters and Coalescers with Automatic Drains

In-Line Filters and Coalescers with Automatic Drains Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal) Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal) IMPORTANT: It is imperative that the user read these warnings and use of the assembly instructions

More information

1 DESCRIPTION OF THE APPLIANCE

1 DESCRIPTION OF THE APPLIANCE 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers

More information

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you! CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different

More information

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For: 3M Water Filtration Products Installation and Instruction Manual For: CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings Installer: Please leave this manual with owner/operator. Owner/Operator:

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.

Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY. Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY. Air Pressure 586.1 min 689.5 kpa max [85 min 100 psi max] Air Displacement 721,000 mm 3 [44 in. 3 ] Figure 1 Weight

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1 Hydraulic Air Riveter Recommend for mass production line industrial area Operation Manual RC197 RC198 Page 1 CONTENTS 1 Important Safety Rules 2 Tool Specification 2.1 Nomenclature 2.2 Technical Data 3

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY RESULT IN INJURY TO YOU OR DAMAGE TO

More information

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC 8mm Solenoid Valve Typical Applications Portable Equipment Blood Pressure Monitoring Wound Therapy Air and Oxygen Delivery Sensor Zeroing Product Specifications Mechanical Valve Type: 3-Way, Solenoid-actuated

More information

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 BACKPACK SPRAYERS MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use only with

More information

Threaded Inline Air Heaters

Threaded Inline Air Heaters Threaded Inline Air Heaters FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow

More information

Section 6 Brake Drum Failure Analysis. Brake Drum Wear Conditions. What is Normal Wear? What is Deep or Excessive Wear? WARNING. Deep, Uniform Wear

Section 6 Brake Drum Failure Analysis. Brake Drum Wear Conditions. What is Normal Wear? What is Deep or Excessive Wear? WARNING. Deep, Uniform Wear Section Brake Drum 6 Failure Analysis WARNING To prevent serious eye injury, always wear safe eye protection when you perform vehicle maintenance or service. Figure 6.1 ASBESTOS AND NON-ASBESTOS FIBERS

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in

More information

15GAL STEEL OIL DRAIN WITH 110V PUMP

15GAL STEEL OIL DRAIN WITH 110V PUMP 15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

COMPRESSED AIR DRYER

COMPRESSED AIR DRYER COMPRESSED AIR DRYER Model 40211 ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2002 by Harbor Freight Tools.

More information

Compressor Service & Maintenance Manual

Compressor Service & Maintenance Manual Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance

More information

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and

More information

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER... FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE

More information

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions 795 08690 GM 12 00 Graymills Air Operated Double Diaphragm Pumps Operations and Maintenance Instructions /S Read all these SAFETY INSTRUCTIONS BEFORE installing or using this equipment. Keep this manual

More information

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev. Structural Bolting ASTM A325 and ASTM A490 are the two U.S. standard structural bolts. When looking at the mechanical requirements of bolts it appears that an ASTM A325 and SAE J429 Grade 5 are identical

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

OP300S / OP350 2:1 RATIO TRANSFER PUMP

OP300S / OP350 2:1 RATIO TRANSFER PUMP OP300S / OP350 2:1 RATIO TRANSFER PUMP OPERATING MANUAL WITH PARTS IDENTIFICATION Copyright 2013 International Pump Manufacturing, Inc. This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. Read and

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner

More information

Hydraulic control unit series 0086-372-01

Hydraulic control unit series 0086-372-01 Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3

More information

UV100A Ultraviolet Air Treatment System

UV100A Ultraviolet Air Treatment System UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism

More information

HOSE, TUBE, AND PIPE CLAMPS

HOSE, TUBE, AND PIPE CLAMPS hose, tube & clamp B/W pages 24/6/08 9:28 AM Page 2 HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions

More information

Dryaire Desiccant System

Dryaire Desiccant System Instructions/Parts Dryaire Desiccant System 310595F Model 6760 Maximum Operating Pressure: 160 PSI (1.1 MPa, 11 bar) System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance

More information

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Maintenance Manual 31 System Saver 318 Air Compressor for Mack E-Tech and ASET Engines Revised 08-05 NON-THROUGH DRIVE THROUGH DRIVE Service Notes About This Manual This manual provides service and repair

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com. Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

Dissolved Oxygen Sensors

Dissolved Oxygen Sensors Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit

More information

3097 en - 2013.06 / e. This manual is to be given to the end user POULIBLOC 2000-3000. Shaft mount reducer. Installation

3097 en - 2013.06 / e. This manual is to be given to the end user POULIBLOC 2000-3000. Shaft mount reducer. Installation 097 en - 0.06 / e 8 en This manual is to be given to the end user POULIBLOC 000-000 Installation LEOY-SOME ISTALLATIO POULIBLOC 000-000 097 en - 0.06 / e This document complements the general instructions

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information