Applications. LB Type 2-1/2-4 NEC 6x. C Type NEC 8x LB Type 1-2 NEC 6x. UB Type NEC 6x LR Type NEC 6x LL Type NEC 6x
|
|
- Daniel Walton
- 7 years ago
- Views:
Transcription
1 NEC 6x8x Series C, LB, UB and LL, LR, T Mogul Unilet Conduit Outlet Bodies For use with Threaded Rigid Metal Conduit and IMC. Complete with Assembled Cover and Neoprene Gasket. Applications Larger body size facilitates pulling of large and heavy conductors. Specially designed raised cast covers provide additional wiring area. Mogul Unilets for pulling straight, 5 or 90 angle turns and/or making taps and splices. Features Exclusive built-in rollers facilitate cable pulling. Available on NEC 6x8x Series Moguls (C, LB and UB) in sizes -/ and up. Smooth, rounded integral bushing in each hub protects conductor insulation. Accurately tapped, tapered threads for tight, rigid joints and ground continuity. Covers have captive stainless steel screws to speed installation, prevent freezing of screws. LB and UB Moguls Length Requirement: distance between centerline of each hub bushing (conduit stop) exceeds six times the trade diameter of the conduit per NEC 3.8(A)(). Bending Space Requirement: these moguls also meet the NEC 3.8(A)() Exception requirement spelled out in NEC 3.6(A) Table. C Moguls Length Requirement: distance between centerline of each hub bushing (conduit stop) exceeds eight times the trade diameter of the conduit per NEC 3.8(A)(). Bending Space Requirement: not applicable. LL and LR Moguls Like LB moguls, these moguls have an end hub. The second hub is in the side (LL left and LR right) instead of the back. T Moguls These are like C moguls ( thru ), except with an additional middle side hub. Distance between the centerline of each C hub conduit stop exceeds eight times the trade diameter of the conduit per NEC 3.8(A)(). Standard Materials Bodies and covers: malleable iron or copperfree (/0 of % max.) aluminum Gaskets: neoprene Screws: stainless steel Standard Finishes Malleable iron bodies and covers: triple-coat () zinc electroplate, () chromate and (3) epoxy powder coat Aluminum bodies and covers: epoxy powder coat NEC/CEC Certifications and Compliances UL Standard: 5B UL Listed: E57 CSA Standard: C. No. 8.3 CSA Certified: NEMA Standard: FB- C NEC 8x LB - NEC 6x LB -/ - NEC 6x UB NEC 6x LR NEC 6x LL NEC 6x T NEC 8x Rollers make cable-pulling easier, eliminate insulation damage Fittings NEC/CEC CONDUIT BODIES If less than maximum conductors permitted by NEC are used, smaller wires may be used additionally through LL, LR or T hubs. If large conductors are required to be bent in LL, LR or T direction, order junction boxes instead. See Enclosures and Junction Boxes. Visit our website at or contact us at (800) May 0 3
2 NEC 6x8x Series C, LB, UB Mogul Unilet Conduit Outlet Bodies For use with Threaded Rigid Metal Conduit and IMC. Complete with Assembled Cover and Neoprene Gasket. Hub Size Body, Cover and Gasket Cover and Gasket Malleable Iron Aluminum Gasket Only Malleable Iron Aluminum C NEC 8X Fittings BC00-M BC00-A BG00 BKG00-M BKG00-A -/ BC5-M BC5-A BGC5 BKGC5-M BKGC5-A - -/ BC50-M BC50-A BG50 BKG50-M BKG50-A BC00-M BC00-A BGC00 BKGC00-M BKGC00-A NEC/CEC CONDUIT BODIES LB NEC 6X -/ - -/ BC50-M BC50-A BGC50 BKGC50-M BKGC50-A 3 BC300-M BC300-A BGC300 BKGC300-M BKGC300-A 3-/ BC350-M BC350-A BGC350 BKGC350-M BKGC350-A BC00-M BC00-A BGC00 BKGC00-M BKGC00-A BLB00-M BLB00-A BG00 BKG00-M BKG00-A -/ BLB5-M BLB5-A BGL5 BKGL5-M BKGL5-A -/ BLB50-M BLB50-A BG50 BKG50-M BKG50-A - BLB00-M BLB00-A BGL00 BKGL00-M BKGL00-A -/ BLB50-M BLB50-A BGL50 BKGL50-M BKGL50-A 3 BLB300-M BLB300-A BGL300 BKGL300-M BKGL300-A 3-/ BLB350-M BLB350-A BGL350 BKGL350-M BKGL350-A -/ - BLB00-M BLB00-A BGL00 BKGL00-M BKGL00-A UB NEC 6X BUB00-M BUB00-A BG00 BKG00-M BKG00-A -/ BUB5-M BUB5-A BGL5 BKGL5-M BKGL5-A -/ BUB50-M BUB50-A BG50 BKG50-M BKG50-A - BUB00-M BUB00-A BGL00 BKGL00-M BKGL00-A -/ BUB50-M BUB50-A BGL50 BKGC50-M BKGC50-A 3 BUB300-M BUB300-A BGL300 BKGU300-M BKGU300-A 3-/ BUB350-M BUB350-A BGL350 BKGC350-M BKGC350-A -/ - BUB00-M BUB00-A BGL00 BKGU00-M BKGU00-A Furnished with rollers for easier cable pulling. 3 Visit our website at or contact us at (800) May 0
3 NEC 6x8x Series LL, LR, T Mogul Unilet Conduit Outlet Bodies and Wiring Capacity For use with Threaded Rigid Metal Conduit and IMC. Complete with Assembled Cover and Neoprene Gasket. Hub Size Body, Cover and Gasket Cover and Gasket Malleable Iron Aluminum Gasket Only Malleable Iron Aluminum LL NEC 6X LR NEC 6X T NEC 8X - - BLL00-M BLL00-A BG00 BKG00-M BKG00-A -/ BLL5-M BLL5-A BGL5 BKGL5-M BKGL5-A -/ BLL50-M BLL50-A BG50 BKG50-M BKG50-A BLL00-M BLL00-A BGL00 BKGL00-M BKGL00-A BLR00-M BLR00-A BG00 BKG00-M BKG00-A -/ BLR5-M BLR5-A BGL5 BKGL5-M BKGL5-A -/ BLR50-M BLR50-A BG50 BKG50-M BKG50-A BLR00-M BLR00-A BGL00 BKGL00-M BKGL00-A Fittings NEC/CEC CONDUIT BODIES BT00-M BT00-A BG00 BKG00-M BKG00-A -/ BT5-M BT5-A BGC5 BKGC5-M BKGC5-A -/ BT50-M BT50-A BG50 BKG50-M BKG50-A - BT00-M BT00-A BGC00 BKGC00-M BKGC00-A -/ BT50-M BT50-A BGC50 BKGC50-M BKGC50-A 3 BT300-M BT300-A BGC300 BKGC300-M BKGC300-A 3-/ BT350-M BT350-A BGC350 BKGC350-M BKGC350-A -/ - BT00-M BT00-A BGC00 BKGC00-M BKGC00-A Wiring Capacity for Mogul Bodies with Covers: Malleable Iron and Aluminum Hub Size Mogul Capacity dm 3 (in 3 ) Hub Size Mogul Capacity dm 3 (in 3 ) -/ -/ C, LB, LL, LR, T, UB 0.50 (3.00) -/ C, T 5.9 (335.00) LB 3. (0.00) C, T 0.8 (50.00) UB 6.5 (375.00) LB 0.79 (8.00) C, T 7.78 (75.00) LL, LR 0.69 (.00) 3 LB 5.65 (35.00) UB 0.66 (0.00) UB 7.9 (5.00) C, LL, LR, T.5 (93.00) C, T 3.60 (830.00) LB.75 (07.00) 3-/ LB 8.9 (500.00) UB.9 (9.00) UB 3.77 (80.00) C, T.3 (3.00) C, T 6.55 (00.00) LB.37 (5.00) LB.3 (70.00) LL, LR, UB.0 (3.00) UB 5.73 (960.00) Visit our website at or contact us at (800) May 0 33
4 Bending Radius and Bending Space of NEC 6x8x Series LB and UB Mogul Bodies Bending Radius of Moguls Catalog Number Hub Size R Millimeters R Fittings BLB00-A,M. (.63) 66.8 (.63) BLB5-A,M -/ 57. (.5) 9. (3.63) BLB50-A,M -/ 66.8 (.63) 0.9 (.3) NEC/CEC CONDUIT BODIES LB Mogul - LB Mogul -/ - LB BLB00-A,M 76. (3.00) 7.0 (5.00) BLB50-A,M -/ 98.6 (3.88) 58.8 (6.5) BLB300-A,M (5.00) 03. (8.00) BLB350-A,M 3-/ 7.0 (5.00).9 (8.38) BLB00-A,M 58.8 (6.5) 60. (0.5) BUB00-A,M.3 (.50) 39.7 (5.50) BUB5-A,M -/ 7.6 (.63) 5. (6.00) BUB50-A,M -/ 77.8 (7.00) 5.9 (8.50) UB BUB00-A,M 90.5 (7.50).3 (9.50) BUB50-A,M -/ (3.3) (5.50) BUB300-A,M (3.88) 8.8 (6.88) UB Mogul - BUB350-A,M 3-/ 50.7 (9.75) (3.5) BUB00-A,M 57. (0.75) 68.7 (.75) Compliances with NEC Bending Space Requirements Bending Space Defined NEC 370.8(A)() Exception. This article applies to LB and UB Moguls, defines bending space and refers to NEC 3.6(B) Table as guideline for determining minimum bending space distance. Bending space is illustrated as Dimension A below: Bending Space of Moguls (Dim. A in sketches at left) Mogul Size Distance LB, UB -/ -/ LB, UB 3-/ -/ LB, UB LB, UB 5 -/ LB, UB 6 3 LB, UB 8 3-/ LB, UB 8 AWG or Circular-Mill. Minimum Wire Bending Space NEC 3.6(B) Table: The applicable portion of this table is shown below. Only the Wire Per Terminal column is retained, because the others are not applicable. Example for using table below and table at right: 350MCM wire size requires 5 bending space. A LB or UB Appleton Mogul is suitable. LB, UB 0 Size of Wire Wire per Terminal Min. Bending Space LB Mogul - -0 Not Specified LB Mogul -/ - NOTE ON RADIUS TABLE: Secure cable or wire bending radius from manufacturer. Then select a mogul having this radius or more. If radius is 6-/, an LB -/ mogul or BUB -/ mogul is suitable. NOTE ON NEC 3.6(B) TABLE: Because cable sizes vary, table is limited to single wire sizes. Use as guideline only for cable sizes / -3 -/ / MCM -/ MCM MCM MCM MCM 8,000-,50 MCM 0 UB Mogul -,500-,000 MCM 3 Visit our website at or contact us at (800) May 0
5 NEC 6x8x Series C Mogul Bodies Comply with NEC Large-Wire Requirements Applicable NEC References for C, LB and UB Moguls Straight Pull Length Requirements: NEC 3.8(A)() C Moguls... shall not be less than eight times the trade diameter of the largest raceway. (See table at right.) Angle or U Pull Length Requirements: NEC 3.8(A)() LB, UB Moguls The distance between each raceway entry inside the box and the opposite wall of the box shall not be less than six times the trade diameter of the largest raceway. (See next page.) Bending-Space Requirements: NEC 3.8(A)(). Exception 3.6(A) Table LB, UB Moguls Where a conduit or cable entry is in the wall of a box or conduit body opposite to a removable cover. (See dim. A, table right) Length and Bending Space Requirements: C Mogul thru LB Mogul thru LB Mogul -/ thru UB Mogul thru BENDING SPACE EXAMPLE: LB with 3 hubs (Cat. No. BLB300-M) using 500 MCM wire with four conductors. Table on next page shows that, in this example, NEC requires a bending space of 6 and that the Appleton 3 LB provides a bending space of 8. * Dimension A is bending space. C Moguls Straight Pulls: Maximum Number of Conductors, Minimum Lengths Wire Size Maximum Number of Conductors per NEC Length Requirements (Conduit Stop to Conduit Stop) Per NEC Appleton Maximum Number of Conductors per NEC Length Requirements (Conduit Stop to Conduit Stop) Per NEC Appleton Hubs BC00-M and BC00-A -/ Hubs BC5-M and BC5-A / Hubs BC50-M and BC50-A Hubs BC00-M and BC00-A / Hubs BC50-M and BC50-A 3 Hubs BC300-M and BC300-A / Hubs BC350-M and BC00-A Hubs BC00-M and BC00-A NEC 370.8(A). Limited to minimum # wire. NEC Chapter 9, Table 3B. NEC 370.8(A)(). This is 8 times conduit trade size. Fittings NEC/CEC CONDUIT BODIES Visit our website at or contact us at (800) May 0 35
6 NEC 6x8x Series LB, UB Mogul Bodies Comply with NEC Large-Wire Requirements Fittings NEC/CEC CONDUIT BODIES LB and UB Moguls- Angle or U Pulls: Max. No. Conductors, Min. Lengths, Min. Bending Spaces Wire Maximum Number of Length Requirements (Conduit Stop to Conduit Stop) (A) Bending Space Requirements Maximum Number of Length Requirements (Conduit Stop to Conduit Stop) (A) Bending Space Requirements Size Conductors Per Per Conductors Per Per per NEC NEC Appleton NEC Appleton per NEC NEC Appleton NEC Appleton Hubs BLB00-M, BLB00-A, BUB00-M and BUB00-A -/ Hubs BLB5-M, BLB5-A, BUB5-M and BUB00-A 6 6 -/ 7 7-/ 7-/ 3-/ / 6 7-/ 7-/ 3-/ / -/ 5 7-/ 7-/ -/ 3-/ / 7-/ 3 3-/ / 7-/ 3-/ 3-/ -/ Hubs BLB50-M, BLB50-A, BUB50-M and BUB50-A Hubs BLB00-M, BLB00-A, BUB00-M and BUB00-A / -/ / 7 3-/ / 6 3-/ / / Hubs BLB50-M, BLB50-A, BUB50-M and BUB50-A 3 Hubs BLB300-M, BLB300-A, BUB300-M and BUB300-A / / / / / / / / / Hubs BLB350-M, BLB350-A, BUB350-M and BUB350-A Hubs BLB00-M, BLB00-A, BUB00-M and BUB00-A / 8 3 -/ / / / 8 3-/ / 8 -/ NEC 370.8(A). Limited to minimum # wire. NEC Chapter 9, Table 3B. NEC 370.8(A)() This is 6 times conduit trade size. NEC 370.8(A)() Exception (3.6(B) Table). This is distance A bending space illustrated on preceding page. 36 Visit our website at or contact us at (800) May 0
7 NEC 6x8x Series C, T, LL, LR Mogul Body Dimensions Mogul C T LL, LR Hub Trade Size -/ -/ -/ 3 3-/ -/ -/ -/ 3 3-/ -/ -/ s C, T Dimensions in Millimeters s LB, LL, LR A B C D E F G H J K (9.8) (.75) (.38) (.88) (6.63) (0.9) (.) (.88) (.00) (3.3) (.38) (.88) (7.69) (.6) (3.00) (.9) (3.9) (3.75) (3.3) (.50) (9.3) (.38) (3.38) (.56) (7.9) (.) (3.3) (.50) (3.00) (.63) (.00) (3.8) (3.5) (5.3) (.63) (3.75) (7.50) (.8) (.63) (3.63) (6.88) (5.9) (.63) (3.63) (.00) (.6) (5.) (.38) (3.38) (7.9) (5.63) (.50) (.9) (.50) (6.69) (.88) (35.38) (7.56) (5.63) (.50) (8.9) (.75) (7.06) (5.5) (9.8) (.75) (.38) (.88) (6.63) (3.5) (0.9) (.) (.88) (.00) (3.3) (.38) (.88) (8.56) (3.38) (.6) (3.00) (.9) (3.9) (3.75) (3.3) (.50) (0.38) (.3) (.38) (3.38) (.56) (7.9) (.) (3.3) (.50) (.3) (.3) (.63) (.00) (3.8) (3.5) (5.3) (.63) (3.75) (8.69) (6.00) (.8) (.63) (3.63) (6.88) (5.9) (.63) (3.63) (.9) (6.00) (.6) (5.) (.38) (3.38) (7.9) (5.63) (.50) (6.9) (7.5) (.50) (6.69) (.88) (35.38) (7.56) (5.63) (.50) (30.9) (7.5) (.75) (7.06) (5.5) (8.9) (.75) (.38) (.88) (6.63) (3.5) (0.9) (.) (7.88) (.88) (9.69) (3.3) (.38) (.88) (7.5) (3.38) (.6) (3.00) (8.50) (.9) (3.00) (3.75) (3.3) (.50) (0.38) (.3) (.38) (3.38) (.63) (.56) (.63) (5.00) (3.3) (.50) (.8) (.3) (.63) (.56) (.9) (3.) Number of Cover Holes Fittings NEC/CEC CONDUIT BODIES Furnished with rollers for easier cable pulling. Visit our website at or contact us at (800) May 0 37
8 NEC 6x8x Series LB, UB Mogul Body Dimensions Fittings NEC/CEC CONDUIT BODIES Mogul LB UB Hub Trade Size -/ -/ -/ 3 3-/ -/ -/ -/ 3 3-/ LB -/" thru " UB Dimensions in Millimeters Number A B C D E G H J K L of Cover Holes (8.9) (3.63) (.38) (.88) (6.63) (0.9) (.) (7.88) (.88) (.88) (9.69) (.75) (.38) (.88) (6.3) (.6) (3.) (8.50) (.63) (.6) (3.00) (5.5) (3.3) (.50) (9.3) (.38) (3.9) (.63) (3.06) (.38) (.63) (6.3) (3.3) (.50) (0.75) (.63) (.88) (.9) (3.) (.69) (7.88) (8.00) (5.88) (3.50) (3.75) (.3) (.3) (5.8) (.56) (.06) (0.00) (5.88) (3.50) (7.00) (.50) (5.3) (8.50) (5.38) (.3) (0.5) (7.00) (.63) (9.88) (3.00) (.75) (.38) (6.63) (7.50) (.50) (7.00) (.63) (3.00) (3.5) (6.38) (.38) (7.00) (9.63) (3.50) (.38) (.88) (6.63) (.) (8.) (.88) (0.5) (.3) (.38) (.88) (6.3) (3.00) (8.9) (.9) (3.69) (.63) (3.3) (.50) (9.3) (3.38) (.9) (.56) (5.5) (5.00) (3.3) (.50) (0.75) (.56) (3.38) (3.8) (.88) (7.06) (.63) (3.75) (7.50) (5.) (0.3) (.38) (.88) (7.3) (.63) (3.75) (7.50) (6.8) (0.3) (.38) (30.88) (8.9) (5.63) (.50) (.88) (7.06) (7.50) (5.5) (30.88) (0.3) (5.63) (.50) (.88) (8.) (7.50) (5.5) Furnished with rollers for easier cable pulling. 38 Visit our website at or contact us at (800) May 0
GUE, GUB Junction Boxes
E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof
More informationFITTINGS: CAST DEVICE BOXES. Applications. Illustrated Features
and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Ridge Top Construction. Furnished with Internal Ground Screw. Fittings FITTINGS: CAST DEVICE BOXES
More informationTMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations
TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations CableReady connectors are designed for use with the following cables: Type MC jacketed corrugated aluminum, interlocked
More informationCable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:
QA1 General Information are used to support cables in vertical raceways or risers. Cable supports relieve the strain that would be placed on terminations, the interior of panels, or other devices to which
More information18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30
Commercial Products COMMERCIAL PRODUCTS: RIGID AND IMC FITTINGS s Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels,
More informationMyers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure
Myers Hubs The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure Myers Hubs The Original! Often imitated, never duplicated! Available in a wide range of sizes, materials
More informationConduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC)
Conduit Tubing Electrical Metallic Tubing (EMT) Intermediate Metal Conduit (IMC) Hot-Dip Galvanized Steel Rigid Metal Conduit (RMC) Download Buy American Brochure Includes 2011 National Electrical Code
More informationELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS
Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document
More informationAmerican National Standard. Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and Cable
ANSI/NEMA FB 1-2012 Revision of ANSI FB 1-2007 American National Standard Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and Cable Secretariat: National Electrical
More informationAMERICAN FITTINGS. Corporation. SPEC-grade. Rigid-IMC Connectors Compression Type - (No Thread)
Connectors / Compression Type Size Range: 1/2 to 5 Rigid-IMC Connectors Compression Type - (No Thread) Industrial specification grade, screw machined steel, zinc plated UL Listed RIN TIGHT and Concrete
More informationConduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
More informationLighting Accessories Hazardous and Non-hazardous
Lighting Accessories Hazardous and Non-hazardous Description Page No. Application/Selection see page 082 Hazardous Area Hangers Adjustable Type UNR see page 099 Flexible Type EC Series see page 09 Locking
More informationFLB Series Circuit Breakers and Enclosures
FLB Series Circuit Breakers and s Applications: FLB circuit breakers and enclosures are used: F service entrance, feeder branch circuit protection f lighting, heating, appliance and mot circuits In areas
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More information26 0533 Raceway and Boxes for Electrical Systems Page 1 of 7
Last Update: November, 2015 A. Conduits: Consultant s Handbook Page 1 of 7 1. All conductors for each and every electrical system shall be installed in a raceway except communications and A/V systems which
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent
More informationJIC CONTINUOUS HINGE BOXES
JIC CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing.
More informationELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
More informationGuidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
More informationHIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE
Electrical Conduit & Fittings Catalog HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE Payment Terms: Payment terms are printed on every invoice. Invoices not paid in full by the net due
More informationAMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationWeatherproof Products
Cooper Crouse-Hinds Commercial Products Weatherproof Products Complete line of Weatherproof Products includes: Outlet Boxes & Covers Conduit Outlet Bodies, Covers & Gaskets Vaporproof Lighting Cast Enclosures
More informationDESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4
DESCRIPTION PAGE B7 Studs and Nuts Stud Bolts for Pressure-Temperature Piping 2-1 General Purpose End-to-End Studs 2-2 Tap End Stud Bolts 2-3 Double End Stud Bolts 2-4 Sigma Fasteners, Inc. Section 2 STUD
More informationType 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
More informationCONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
More informationSECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.
SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but
More informationScepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
1312-1313.qxp 12/16/2013 7:04 PM Page 1312 Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Features: Arktite circuit breaking plugs and receptacles are
More informationSTB Series Enclosures
STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard
More informationThe National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
More informationAC METRIC (IEC) MOTORS THREE PHASE
AC METRIC MOTORS These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools,
More informationElbows, Couplings & Nipples (EC&N)
Elbows, Couplings & Nipples (EC&N) The trusted name in steel North America s Best-in-Class Electrical Elbows, Couplings & Nipples for more than 135 years. Established in 1877, Wheatland Tube is the longest-running
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationCLEANOUT FEATURES. KLEENATRON II Features CLEANOUTS
CLEANOUT FEATURES KLEENATRON II Features JOSAM KLEENATRON II Cleanouts incorporate features developed to meet the latest in building construction methods. These features ensure the specifier, installer
More informationGuidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
More informationQuick Connect Boxes Inside Gloveboxes
ULC Series Junction Boxes Quick Connect Boxes Inside Gloveboxes The ULC quick connect junction boxes are the essential elements to optimize the cabling inside gloveboxes. Large range Designed for nuclear
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationExplosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
More informationSPEC AMERICAN. SPEC BRIDGEPORT.
SPE MERIN. SPE RIDGEPORT. ridgeport Zinc or Steel Meets: UL514 Specifications: --50552 Fittings for able and Flexible Metal onduit --50553 Fittings for Rigid and EMT onduit --50563 onduit Outlet oxes,
More informationHeating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationEast Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE
SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders,
More informationLow Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
More informationCarlon Carflex Liquidtight Flexible Tubing
Carlon Carflex Liquidtight Flexible Tubing Carflex Carflex X-Flex Fittings Cord Grips Pre-Wired Whips www.carlon.com 3 Carflex Liquidtight Flexible Conduit Carflex Liquidtight Flexible Nonmetallic Conduit
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationMESSENGERS FOR AERIAL CABLE
MESSENGERS FOR AERIAL CABLE COPPERWELD - EHS, 30% CONDUCTIVITY MES(size)CUWELD Size O.D. Stranding Breaking Strength Wgt./Mft. MES1/4CUWELD 1/4".242 7 #12 5,783 lbs. 128 MES5/16CUWELD 5/16".306 7 # 10
More informationCable and Cord Reels. Section R. Cable and Cord Reels Index. Index
Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device
More information880 HYDRAULIC BENDER
OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL 880 HYDRAULIC BENDER Read and understand this material before operating or servicing this tool. Failure to understand how to safely operate this tool could
More informationElectrical Code Regulation
Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county
More informationNORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS
SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications
More informationBID TABULATION Fiber Optic Cable Materials Bid #0111-147 March 16, 2011 at 11:00 am CDT
1 251,200 LF 2 HDPE-SDR 13.5 with pull tape Unit Price $0.5679 $0.527 $0.593 $0.630 Extended Price $142,656.48 $0.00 $132,382.40 $148,961.60 $158,256.00 2 251,200 LF 2 HDPE-SDR 13.5 without pull tape Unit
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationwww.jameco.com 1-800-831-4242
Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control
More informationHOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12
SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications
More informationCTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
More informationSMA Interface Mating Dimensions (Per MIL-STD-348)
SMA Series SMA 6 SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Interface Dimensions MALE Inches/Millimeters 3 Minimum Nominal Maximum LTR in. mm in. mm in. mm A.250 6.35.263 6.68.. B.1790 4.55.1808
More information12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationONTRAC WIRE MESH CABLE TRAY SYSTEM
P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network
More informationScrew Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More informationCRASH RAIL INSTALLATION HEIGHT
PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION OF THIS. CONTAINED
More informationAMP Standard Terminals and Splices. RoHS. Ready
AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control
More informationFLEXTRAY. It s Simple Cable Management CBFT-10. Catalog & Product Installation Guide
CBFT-10 FLEXTRAY It s Simple Cable Management Catalog & Product Installation Guide Flextray Flextray is a flexible, field-adaptable way to manage cables throughout your project. The tray itself can be
More informationSECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
More informationSports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
More informationSECTION 16402 UNDERGROUND ELECTRIC SERVICE
SECTION 16402 UNDERGROUND ELECTRIC SERVICE PART 1 GENERAL 1.1 SUMMARY A. Description of System 1. Furnish all labor, materials, and equipment for below grade work external to buildings as required, and
More information2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61
30"-64" Ductile Iron industrial Applications, water & Wastewater 2 Table of Contents Flanged Fittings for Water 3 Flange Details 5 Flanged Fittings 6 90º and 45º Bend 6 22-1/2º and 11-1/4º Bends 7 Tees
More informationExplosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationAmerican National Standard For Electrical Rigid Steel Conduit (ERSC)
Revision of ANSI C80.1-1994 American National Standard For Electrical Rigid Steel Conduit (ERSC) Secretariat: Approved August 18, 2005 American National Standards Institute, Inc. NOTICE AND DISCLAIMER
More information5.2. Overview. The better method to install solderless compression connectors on power cable
5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree
More informationSECTION 16110 CONDUITS, RACEWAYS, FITTINGS AND CABLE TRAYS
SECTION 16110 CONDUITS, RACEWAYS, FITTINGS AND CABLE TRAYS PART 1 - GENERAL 1.01 REQUIREMENTS A. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements,
More informationSPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB
SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB
More informationPHOTOVOLTAIC ARRAY WIRING HANDBOOK FOR STANDARD NOMINAL 6, 12, 24, AND 48 VOLT SYSTEMS. (for SX-60 series or smaller and MSX-120 solar modules)
PHOTOVOLTAIC ARRAY WIRING HANDBOOK FOR STANDARD NOMINAL 6, 12, 24, AND 48 VOLT SYSTEMS (for SX-60 series or smaller and MSX-120 solar modules) COPYRIGHT INFORMATION BP Solarex holds all copyrights for
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationMR221-MR222 Heavy Duty Geared Limit Switches, CE Approved
MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MICRONOR automation components Product MICRONOR MR221 and MR222 series Heavy Duty Geared Limit Switches are for use in the most demanding industrial
More informationUPBLAST & HOODED PROPELLER ROOF VENTILATORS
The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust
More information98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.
81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX
More informationOutdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
More informationSocket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY
Screwless Clamp Terminal Socket Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double wiring
More informationPUSH-PULL CABLES CONTROL SYSTEMS
ISO 9001 CERTIFIED PUSH-PULL CABLES CONTROL SYSTEMS WESCON PRODUCTS COMPANY A subsidiary of LATSHAW ENTERPRISES, INC. WESCON'S PUSH-PULL CONTROL SYSTEMS Push-Pull Cable Ends Wescon Push-Pull Cable Assemblies
More informationScepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.
More informationKSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES
KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES KSR-SK-DB The following installation procedures are suggested guidelines for the installation of in-line cable splices. They
More informationHARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
More informationMultiple Meter Installation - 200 Amperes Per Position -Single Phase, Self-contained
Overhead Meters TABLE OF CONTENTS D D Consumer Service Pole for Mobile Home Park Temporary Service -wire Single Phase D. Overhead Meter Installation - Single Phase D. Connection Diagram - Single Phase
More informationNational Craft Assessment and Certification Program S P E C I F I C A T I O N S
National Craft Assessment and Certification Program S P E C I F I C A T I O N S INDUSTRIAL ELECTRICIAN V4 ELEC26_O4 Released September 2013 Focus Statement An Industrial Electrician must be able to interpret
More informationD-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns
for harsh & hazardous (classfied) locations Construction Demolition Maintenance Turnarounds Shutdowns D-13 temporary / mobile power Temporary power products are used on industrial and construction sites
More information* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist...
TABLE OF CONTENTS Custom Molded Cable Assemblies and Connectors..........................2 Capabilities.....................................................................3 Standard Connector Products.......................................................4
More information2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
More informationTIRE & TUBE SECTION DEFINITIONS: OVERALL WIDTH SECTION HEIGHT (D) OVERALL DIAMETER (A) SECTION WIDTH (B) NOMINAL RIM DIAMETER (C)
TIRE & TUBE SECTION Knowing some basic facts about tire dimensions and sizes along with a few technical aspects of tire construction can help clear up much of the confusion many people have in understanding
More informationPOINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES
INCANDESCENT Compliances: ETL Listed to UL 1598 USA ETL Listed to CSA C22.2 No. 250.0-04 Canada ETL Certified FAA L-810 per FAA AC 150/5343G ICAO Annex 14 Low Intensity Types A (10 cd) & B (32 cd) IMO
More informationComponents for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
More informationAMERBRITE UNDERWATER WHITE LED POOL LAMP
AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY WITH PENTAIR AMERLITE LUMINAIRE INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
More informationSECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
More informationType FLX Freezer Floor Frost Heave Protection DESIGN GUIDE
Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE Commercial Products Type FLX TM Freezer Floor Frost Heave Protection DESIGN GUIDE Contents Introduction...2 Application Information... 2-3 Product
More informationPlugs and Receptacles
Plugs and Receptacles Industrial Heavy Duty Interlocked Application and Selection Applications: Where extra protection is a requirement; interlocked units provide dead front receptacles; connection cannot
More informationVdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More information