Supplementary Installation Instructions For use with Morsø Stoves canal boat chimney system

Size: px
Start display at page:

Download "Supplementary Installation Instructions For use with Morsø Stoves canal boat chimney system"

Transcription

1 26 Supplementary Installation Instructions For use with Morsø Stoves canal boat chimney system Conforming to BS 8511:2010 Code of practice for the installation of solid fuel heating and cooking appliances in small craft page 1

2 Please read the instruction manual and these supplementary instructions carefully before installation In all cases the installation should comply with the recommendations given in BSI Standards Publication BS8511:2010 Code of practice for the installation of solid fuel heating and cooking appliances in small craft. Health and Safety Precautions Care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met. Handling Adequate facilities must be available for loading, unloading and site handling. Stove weight including packaging = 70Kg. The appliance, connecting flue pipe and chimney should be installed by a competent person. Ventilation The ventilation requirement for the craft and the fitting of ventilators should follow the guide lines give in BS 8511: 2010 Annex A The effective area of fixed ventilation V, in square millimetres, for accommodation spaces containing combustion appliances should be calculated from the following equation: V = 2200U + 650P + 550H + 440F where: U is the input rating of all unflued appliances, in kilowatts P is the number of persons for which the accommodation space is designed H is the nominal output rating of open-flued solid fuel appliances, in kilowatts F is the input rating for all other open-flued combustion appliances, in kilowatts NOTE Room-sealed appliances are excluded from this calculation. Siting the appliance The stove should not be positioned where it may cause an obstruction or impede escape routes. The stoves location should not create a fire hazard or cause damage to surrounding materials. The stove should be separated from combustible materials in the surrounding structure by the minimum clearances given in table 1 or by adopting the methodology given in BS 8511:2010 section 7. Any combustible material in the vicinity of the stove, whether exposed or covered, e.g. by tiles, should be protected to ensure that its surface temperature of the combustible material does not exceed 65 C above ambient temperature. In situations where the stove is to be fitted adjacent to a non-combustible structure, there should be a minimum clearance of 25mm between the stove and the structure. page 2

3 Table 1: Minumum clearances to combustible surfaces: Stove type Behind the the stove (A) To the sides of the stove (B) Above the stove Clearance to furniture Morsø 1410 insulated chimney Morsø 1430 insulated chimney Morsø 1412 insulated chimney 200mm 550mm 600mm 650mm 400mm 600mm 600mm 650mm 100mm 600mm 500mm 700mm Corner installation A 45 B B B The Hearth The hearth temperature when installed with a Morsø Squirrel 1410, 1412 or 1430 will not exceed 100 C and in accordance with BS 8511:2010 can be installed on a minimum 12mm think suitable non-combustible material. The 12mm thickness can be a single sheet or may be constructed from non-combustible layers. Example, 6mm thick cement board finished with 6mm thick ceramic tiles. The hearth should extend 150mm to the sides and the rear of the stove unless it is adjacent to a suitable surrounding structure. The projection of hearth in front of the stove should be at less 225mm, this distance may be reduced by surrounding the hearth with a non-combustible upstand. page 3

4 Securing the stove The stove must be adequately fixed to the hearth or the craft structure to prevent movement. Hearth fixing brackets are supplied with the Morsø chimney system. Fixings to secure the bracket to the hearth are not provided as hearth material will vary. Hearth fixing brackets Fit the hearth fixing bracket to the back face of the rear legs Placement of smoke hood In some cases Morsø stoves come readyequipped from the factory with a smoke hood, as shown in the diagram below. NOTE: The smoke hood must not be fitted if the chimney is less than 4.5M. The chimney system used on a typical boat installation is likely to have an effective height of 2 2.5m and the smoke hood must not be fitted. Ensure that the firebricks, riddling grate assembly and baffle plate are positioned correctly. Back brick Smoke hood Baffle plate Side brick Riddling grate assembly Chimney System The stove should be installed with the purpose made Morsø chimney system (part number or ). Alternatively the chimney system should meet the requirements of BS 8511:2010 section 8. Height The connecting flue pipe and or chimney should not be less than 2M from the appliance outlet to the chimney terminal outlet. The chimney terminal should be minimum 600mm above the deck when the craft is moored. The termination may be shorter when the craft in underway but may not be less than 150mm above the deck. page 4

5 Installation of the Morsø chimney system chimney system with fixed 12 bend 2 x 1M lengths inc 12 offset of chimney 1 x Deck plate 1 x 550mm external chimney 1 x Terminal 1 x Blanking cap 4 x Clamping rings 2 x Hearth securing brackets Self adhesive gasket Straight chimney system 2 x 1M lengths of chimney 1 x Deck plate 1 x 550mm external chimney 1 x Terminal 1 x Blanking cap 4 x Clamping rings 2 x Hearth securing brackets Self adhesive gasket Locating the deck plate Use a suitable non silicon based water tight sealant on the deck of the craft before locating the deck plate. Insert the deck plate, ensuring it is the correct way up. Male connection up - female connection down. page 5

6 Locating the deck plate cont... Apply water tight sealant around the location holes and insert fixing bolts. Once the bolts are tightened and the deck plate is secure seal around the edge of the deck plate and around the chimney pipe where it passes through the plate. The Chimney Apply the self adhesive gasket provided around the outside face of the inner chimney pipe. The gasket should only be used on the end of the chimney that connects to the stove collar. The gasket will form the seal between the chimney and the stove; no other fixing is required. However the chimney and collar can be drilled and fixed if preferred. Connect the two 1M lengths of chimney system together. The chimney connection is telescopic and the internal insulation used in the upper chimney will compress as the sections of pipe are assembled. Locate the stove on the hearth in the approximate position (do not drill the hearth fixings at this stage) Locate the assembled chimney system onto the cast iron flue collar of the stove. Adjust the assembled chimney to the required length and connect on to the deck plate and fix with a clamping band. page 6

7 If required a clamping ring can be fixed around the telescopic joint, however there is likely to be a considerable overlap at the point and therefore the joint will be structurally sound. This joint is designed to move and will overcome any issues relating to expansion and contraction associated with a stove installations and the natural movement of the craft. Note: Combustible materials around the chimney such as the cabin headlining must have a minimum clearance of 60mm from the chimney. The connection onto the stove can simply be left or if desired a clamping ring can be used to finish the joint. Finally connect the external chimney pipe and terminal; use locking bands as required. Note: For travelling configuration remove the external chimney and attach the terminal direct onto the deck plate. page 7

8 Commissioning General An appliance/chimney installation should be tested by a competent person before final handover to the user or client to ensure that it is safe, fit for use and capable of providing the expected performance and service, in accordance with the method stated below. The tests and checks given should be carried out before the appliance is lit for the first time. Physical checks The competent person should check that: a) the installation is in accordance with the design, including material specifications, flue length and diameter b) the manufacturer s installation instructions have been followed c) there is no damage to any components d) joints between the appliance and chimney and within the chimney system are secure and in good condition e) the separation of components from combustible materials conforms to manufacturers instructions or BS 8511:2010 f) the appliance and chimney can be fully cleaned, once the installation is complete Smoke evacuation test This test should be carried out to ensure all the smoke is drawn up the flue to atmosphere. It should be ensured that the chimney is complete and any removable section is in the operating position and secured in place according to the user instructions. All doors, windows and closable vents in the cabin should be closed and any extraction fans within the cabin should be switched on. Before commencing the test, the flue should be warmed for at least 10 minutes by a gas blow-lamp or similar placed on the grate. A smoke pellet, with a burn time of approximately 60 seconds or more should be lit and placed on the appliance grate. The main fire door and ash-pan door of the appliance should be closed and the primary and secondary air controls should be fully open. The installation should be checked to determine if smoke is being emitted into the cabin; after 30 seconds, a check should be made to ensure smoke is issuing from the chimney outlet and from no other point outside the cabin. If any smoke is emitted into the cabin from any point on the installation, warm the flue for a further 10 minutes and repeat the test. If any smoke continues to be is emitted into the cabin from any point on the installation the appliance should not be allowed to be lit until the fault has been corrected and the test repeated and passed. CD4590 Design & Print c9dd.com Further details and information can be found on our website:

Installation Instructions

Installation Instructions Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:

More information

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133

More information

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This

More information

FREESTANDING CLEAN AIR WOODBURNER

FREESTANDING CLEAN AIR WOODBURNER Please read this booklet and keep for future reference for the safe installation of your: FREESTANDING CLEAN AIR WOODBURNER This fire conforms with Ecan Requirements All installations must be in accordance

More information

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL Manufactured in New Zealand by: GLEN DIMPLEX AUSTRALASIA LIMITED PO Box 58-473 Botany Auckland 2163 Ph: 0800

More information

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING 6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry

More information

Installation Instructions

Installation Instructions GC 3 (THREE OVEN) Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require.

More information

The Savannah Steel Series Wood Burning Stoves and Inserts

The Savannah Steel Series Wood Burning Stoves and Inserts The Savannah Steel Series Wood Burning Stoves and Inserts The Savannah Steel Series Wood Burning Stoves The wood burning steel stove adds warmth and elegance to any décor. Designed with the latest wood

More information

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E Electric Cookers Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible manufacturers

More information

SRP Pricelist 2015 Including VAT. Stoves for every home

SRP Pricelist 2015 Including VAT. Stoves for every home SRP Pricelist 2015 Including VAT Stoves for every home Valid from 01-10-2015 UK Contents Contura Stoves C400 Series... 2-4 C500 Series... 5-9 C600 Series... 10-13 C700 Series... 14-15 C800 Series... 16-17

More information

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting ING THE WATER HEATER The purpose of venting a gas or oil-fired water heater is to completely remove all products of combustion and to vent gasses to the outside air without condensation in the vent or

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

Flue Installation. High Efficiency Condensing Boilers

Flue Installation. High Efficiency Condensing Boilers Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION

More information

ASX7-4-IOM-7 J30-08579

ASX7-4-IOM-7 J30-08579 INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT

More information

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE. MAJESTIC OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE. CONTENTS Part 1: Safety Information Part 2: Installation

More information

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

Chimneys in Thatched Properties

Chimneys in Thatched Properties Chimneys in Thatched Properties Compliance with Building Regulations when installing or repairing a chimney or re-thatching a roof that abuts a chimney The increasing problem of thatch fires Over the last

More information

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE FITTING YOUR KITCHEN GUIDE How to mark out a kitchen PAGE 1 Before starting on the installation, measure 870mm from the lowest point of the floor and mark a datum line around the room to indicate where

More information

GREENSTAR 60/100 HORIZONTAL FLUE

GREENSTAR 60/100 HORIZONTAL FLUE FLUE KIT INSTALLATION MANUAL 7 76 9 08 ROOM SEALED TELESCOPIC FLUE 7 76 9 7 ROOM SEALED LONGER TELESCOPIC FLUE 7 76 9 086 PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR WORCESTER GREENSTAR

More information

Ravelli Camino Insert Wood Pellet Burning Heater. Wood Pellet Fire Installation Specifications. Safety testing of the

Ravelli Camino Insert Wood Pellet Burning Heater. Wood Pellet Fire Installation Specifications. Safety testing of the Ravelli Camino Insert Wood Pellet Burning Heater Fire shown installed with a non-combustible floor - no hearth required Ravelli Camino Insert Wood Pellet Fire Installation Specifications Safety testing

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

D O U B L E / D O U B L E H A W K 4 C E

D O U B L E / D O U B L E H A W K 4 C E D O U B L E / D O U B L E H A W K 4 C E M U L T I F U E L C L E A N B U R N S T O V E Installation and Operating Instructions An accredited competent person must carry out the installation of this appliance;

More information

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause

More information

Commissioning of Heat Producing Appliances Burning Solid Fuel

Commissioning of Heat Producing Appliances Burning Solid Fuel Building Control Technical Guidance Leaflet No. 15 This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum Commissioning of Heat Producing Appliances Burning Solid

More information

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

RE-3 : SOLID TOP RANGE RANGE TOP ONLY VULCAN ELECTRIC SOlid top oven range MODEL: RE-3 - SOLID TOP oven Range RE-3T - SOLID range top only ON CABINET BASE RE-3 : SOLID TOP RANGE Model Re-3T : Solid TOP RANGE TOP ONLY Index: General Data 2

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

FIRES WITHOUT COMPROMISE EXCEPTIONAL FIRES JETMASTER INSET STOVE. Installation, Operating and Servicing Instructions JETMASTER MK6

FIRES WITHOUT COMPROMISE EXCEPTIONAL FIRES JETMASTER INSET STOVE. Installation, Operating and Servicing Instructions JETMASTER MK6 FIRES WITHOUT COMPROMISE EXCEPTIONAL FIRES JETMASTER INSET STOVE Installation, Operating and Servicing Instructions JETMASTER MK6 Please leave these instructions with the customer SERIAL NUMBER..... Contents

More information

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.

More information

1 DESCRIPTION OF THE APPLIANCE

1 DESCRIPTION OF THE APPLIANCE 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers

More information

Rooflight INSTALLATION INSTRUCTIONS

Rooflight INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary

More information

A new range of clean burning multifuel stoves

A new range of clean burning multifuel stoves A new range of clean burning multifuel stoves The New Range of Bohemia X Multifuel Stoves - approved for wood burning use in smoke control areas throughout the UK* Pevex Enterprises has been established

More information

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure Instruction suitable for both Quadrant & Off-set Quadrant variations. Instruction suitable for both Right and Left Hand fixing variations

More information

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

San josé OWNER S MANUAL

San josé OWNER S MANUAL San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

Across America. Wood & Coal Brochure

Across America. Wood & Coal Brochure Across America Wood & Coal Brochure Rev. Sep. 2011 Bay Series... A series of well built high heat performers featuring decorative side windows and full view glass door with airwash system to help keep

More information

3 IN 1 BATHROOM HEATER

3 IN 1 BATHROOM HEATER 3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing

More information

39HQ Airovision Air Handling Units

39HQ Airovision Air Handling Units 39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Installation Instructions

Installation Instructions Installation Instructions 1. Position the unit onto bridging packers. These keep the unit away from any water sitting inside the frame. 2. Centralise the unit within the frame and pack the edges with appropriate

More information

woodburning stoves installation and procedures

woodburning stoves installation and procedures woodburning stoves installation and procedures REVISED AUGUST, 2006 CONFORMS TO NFPA 211-2006 Legal Disclaimer The information contained herein is not intended to be used as a guide for installation or

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Air Conditioner Duct Construction & Repair

Air Conditioner Duct Construction & Repair PROPER ROOF AIR CONDITIONER MOUNTING At Newmar, there are two different models of air conditioners available on all towable and motorized units. The different models are the Dometic Brisk and Penguin models,

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

Installation Instructions

Installation Instructions VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling

More information

Handcrafted with passion

Handcrafted with passion WOODWARM STOVE S Handcrafted with passion Efficient Green Clean All Woodwarm stoves feature the unique clean burn air wash system. After circulating the stove, pre-heated air flushes down the double glazed

More information

Important Information

Important Information Single Door Quadrant Instruction Manual ESQ Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to

More information

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB Gas Fired Cookers Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB FOR USE IN GB & IE PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible

More information

Installation Instructions for Rayburn 216SFW Solid Fuel and Wood Burning Cooker

Installation Instructions for Rayburn 216SFW Solid Fuel and Wood Burning Cooker Installation Instructions for Rayburn 216SFW Solid Fuel and Wood Burning Cooker Consumer Protection As responsible manufacturers we take care to make sure that our products are designed and constructed

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

USER MANUAL and INSTALLATION MANUAL

USER MANUAL and INSTALLATION MANUAL InisMor USER MANUAL and INSTALLATION MANUAL Inis Mor User manual. Congratulations on the purchase of your Inis Mor back boiler stove. When fitted and operated correctly, you should enjoy many years, trouble

More information

Session 2: Hot Water Supply

Session 2: Hot Water Supply MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

AZB 800. Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884

AZB 800. Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884 AZB 800 Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884 Ø120 1310 Ø125 50 125 6 720 610 703-00.1O for Gas Condensing Boilers: OSW Contents Contents Safety instructions 2 Symbols 2 1 Use 3 1.1 General

More information

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Kemlan Natural Draft Electronic Ignition 3 Sided Gas Fireplaces Natural Draft Electronic Ignition

More information

Installer s Guide 18-AH39D1-13

Installer s Guide 18-AH39D1-13 18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,

More information

from Farm Bureau Insurance

from Farm Bureau Insurance A GENERAL GUIDE TO THE SAFE AND EFFICIENT INSTALLATION AND OPERATION OF WOOD HEATING APPLIANCES from Farm Bureau Insurance Take Extra Care Years ago, when wood heating was more the norm than the exception,

More information

2 Ohm Nominal Coaxial Speaker OWNER S MANUAL

2 Ohm Nominal Coaxial Speaker OWNER S MANUAL 2 Ohm Nominal Coaxial Speaker OWNER S MANUAL 1 page 1 SPL 65 Coaxial Speaker Congratulations on your purchase of the Soundstream SPL 65 Coaxial Speaker. When used with a high quality 2 ohm rated power

More information

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III HOUSES IN MULTIPLE OCCUPATION Space Standards ADOPTED HOUSING STANDARDS:CATEGORY F HOUSES Houses within this category would be of a low priority

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

PRECAUTIONS ON TANKER AND TERMINAL DURING CARGO HANDLING

PRECAUTIONS ON TANKER AND TERMINAL DURING CARGO HANDLING Chapter 24 PRECAUTIONS ON TANKER AND TERMINAL DURING CARGO HANDLING This Chapter provides guidance on precautions to be observed by both tanker and shore when cargo handling, ballasting, bunkering, tank

More information

CHIMNEYS AND FIREPLACES

CHIMNEYS AND FIREPLACES CHAPTER 10 CHIMNEYS AND FIREPLACES > > Pursuant to ORS 215.730, if a single-family dwelling located on forest-zoned lands has a chimney or chimneys, each chimney shall have a spark arrester. SECTION R1001

More information

Wood Heat The Safe Way

Wood Heat The Safe Way Wood Heat The Safe Way A general guide to the safe and efficient installation and operation of wood heating appliances. Prepared by Farm Bureau Insurance in collaboration with Lansing Community College

More information

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray.

More information

ISSUE 2. Installation Guide

ISSUE 2. Installation Guide ISSUE 2 Installation Guide Here at Slide and Fold, we LOVE our Bi-Fold Plus range of folding-sliding doors. We want to ensure that your customers love them too. So we have created a new, detailed installation

More information

sound reduction systems for commercial, educational and industrial environments

sound reduction systems for commercial, educational and industrial environments sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic

More information

Colonnade Security Pipe

Colonnade Security Pipe Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS INSTALLATION & USER INSTRUCTIONS LED ELECTRIC FIRE Focal Point Fires plc. Christchurch, Dorset BH23 2BT Tel: 0202 499330 Fax: 0202 499326 www.focalpointfires.co.uk e : sales@focalpointfires.co.uk MODELS

More information

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base These Instructions are for a left and right handed unit. The diagrams show a left

More information

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email sales@morcoproducts.co.uk Web www.morcoproducts.co.uk Retrofit or Upgrade a Water Heater in a Caravan

More information

MODEL T200-F18 MODEL T125-F18 Finish Nailers

MODEL T200-F18 MODEL T125-F18 Finish Nailers P MODEL T200-F18 MODEL T125-F18 Finish Nailers IMPORTANT! DO NOT DESTROY It is the customer s responsibility to have all operators and service personnel read and understand this manual. OPERATING MANUAL

More information

How To Design A Gas Dryer

How To Design A Gas Dryer Non Domestic Laundry Gas Appliance Installation Code of Practice Introduction This code of practice has been produced with the assistance of all Companies within the OPL sector of SLEAT because of the

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct

More information

orlando OWNER S MANUAL

orlando OWNER S MANUAL orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

Wood Burning Safety Guide

Wood Burning Safety Guide Wood Burning Safety Guide CONTENTS Burning Wood Safely...5 Chimney and Stovepipe Cleaning...8 Chimneys for Wood Stoves...1 Cleaning System...8 Clearances...5 Creosote...8 Disposal of Ashes...8 Draft...2

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made

More information

AGA DUAL CONTROL. Model No s: DC3 & DC5. (Includes External Vent & Room Vent Option)

AGA DUAL CONTROL. Model No s: DC3 & DC5. (Includes External Vent & Room Vent Option) AGA DUAL CONTROL Model No s: DC3 & DC5 (Includes External Vent & Room Vent Option) Installation Guide REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform

More information

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale Installation information METTLER TOLEDO MultiRange DW150 / DW150T wall scale DW150 / DW150T wall scale Contents Contents Page 1. Installation... 2 1.1 Preparatory work... 2 1.2 Installing the wall plates

More information

Gas-Fired, Residential Storage Type Water Heaters

Gas-Fired, Residential Storage Type Water Heaters Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. Gas-Fired, Residential Storage Type Water Heaters Most inspectors

More information

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER DEALER SERVICE AND INSTALLATION MANUAL KIT NO. 00016-30915 Contents PARTS LIST... 2 PARTS ILLUSTRATIONS... 2 VEHICLE PREPARATION... 3 INSTALLING

More information

780 CMR 60.00 CHIMNEYS, FIREPLACES AND SOLID FUEL-BURNING APPLIANCES

780 CMR 60.00 CHIMNEYS, FIREPLACES AND SOLID FUEL-BURNING APPLIANCES 780 CMR 60.00 CHIMNEYS, FIREPLACES AND SOLID FUEL-BURNING APPLIANCES 780 CMR 6001 MASONRY CHIMNEYS 6001.1 General. Masonry chimneys shall be constructed, anchored, supported and reinforced as required

More information

Boiler Plan II Table of Contents

Boiler Plan II Table of Contents Cover Page Table Of Contents Introduction Parts List Additional Materials Assembly instructions Drawings 1-15 Boiler Plan II Table of Contents Introduction This will be a very rewarding project, if you

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

Solid Wood Worktops Installation and Aftercare Instructions

Solid Wood Worktops Installation and Aftercare Instructions Solid Wood Worktops Installation and Aftercare Instructions IMPORTANT NOTE: Please note our worktops have an A and a B side; it is important to identify these prior to making any cuts or other amendments.

More information

MoME/ MoARD/ GTZ-Sustainable Utilization of Natural Resources for Improved Food Security Program. Manual for Production of a Household Rocket Stove

MoME/ MoARD/ GTZ-Sustainable Utilization of Natural Resources for Improved Food Security Program. Manual for Production of a Household Rocket Stove MoME/ MoARD/ GTZ-Sustainable Utilization of Natural Resources for Improved Food Security Program Manual for Production of a Household Rocket Stove Tikikil Ministry of Agriculture and Rural Development

More information

How to build a Pizza Oven in 4 days

How to build a Pizza Oven in 4 days How to build a Pizza Oven in 4 days Preparation day (slab) 1. Foundation 1500 deep x 1300 wide x 75mm deep Required 20 bags cement pre mix. If you already have a concrete base, you save this prep day DAY

More information

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................

More information