A New Type of Combined Neutron/X-ray Digital Imaging System for Explosive Detection and Homeland Security Applications

Size: px
Start display at page:

Download "A New Type of Combined Neutron/X-ray Digital Imaging System for Explosive Detection and Homeland Security Applications"

Transcription

1 A New Type of Combined Neutron/X-ray Digital Imaging System for Explosive Detection and Homeland Security Applications Presented By: Vaibhav Sinha PhD Candidate Department of Nuclear Engineering Missouri University of Science and Technology

2 Motivation A. Different attenuation behaviors of neutron and x-ray produces different radiographic images with different characteristics. For example, boron strongly attenuate neutron but not x-ray B. How about fusing two different images (one using neutron and the other x-ray) of the same object? C. We may be able to extract more information from the fused images. D. How about visualizing the structure and composition of interested objects 3D using this technique?

3 X-Ray Cross Section H D C O Al Si Fe Neutron Cross Section Attenuation Behavior

4 Interaction of (a) neutron and (b) X-ray with an atom.

5 Fusion of neutron and x-ray images (simulated) (a) (a) (b) (b) (c) X-Ray Image Neutron Image Fusion Beryllium Europium Boron Beryllium Europium Boron Beryllium Europium Boron Simulation Assumption: The mono-energetic x-ray energy (50 kev) Thermal neutron energy ( ev)

6 Fusion of neutron and x-ray images (simulated) Borosilicate glasses with different boron concentration X-ray Neutron Fused

7 Past Research A. NDE methods have been applied individually (Neutron or X- ray) for research. B. Failures to obtain comprehensive analysis. C. If applied together, separate experimental set-up were used for neutron and x-ray imaging. D. Such system, difficult to calibrate, prone to measurement inaccuracies and doesn t allow for instant evaluation of imaging objects

8 Objective A.We propose to develop and demonstrate successful operation of a neutron/x-ray combined computed tomography (NXCT) system. B.This is the first approach to develop a neutron and x-ray combined computed tomography system.

9 Radiation Sources Parameter Value Flux at Port Value at 200 kw kv Range ma Range 0 30 Focal Spot 0.4 x1 mm 2 Thermal Neutron Flux Epithermal Neutron Flux ~10 8 n/cm 2 s ~10 6 n/cm 2 s

10 (a) Schematic of MSTR NXCT Facility (b) Photograph of MSTR Neutron Beam Path

11 Neutron Beam Path and Beam Port (Adopted from Bill Bonzer and Christopher M. Caroll, Safety Analysis Report for MSTR, 2008)

12 Isometric view of the NXCT Facility MSTR NXCT neutrons

13 MSTR Full Power Neutron Flux Spectrum (from Kulage Z.A., Mueller G.E., Usman S. and Kumar A., Characterization of Neutron Flux Spectrum at MSTR, M.S. Thesis, 2010)

14 X-Ray Spectrum Generated by Spekcalc Software

15 Sensor Description Scintillator + CMOS X-Ray Image Sensor Parameters Value Pixel Pitch 48 µm Dynamic Range Frame rate Field of View 4000:1 2.7 FPS 5 cm x 5 cm MCP Based Neutron Image Sensor Parameters Value Pixel Pitch 50 µm Dynamic Range 10 7 Sensitivity 0.1 c/cm 2 s Field of View Ф 2.5 cm

16 Selection of MCP Based Neutron Image Sensor A. The imaging object can be placed directly next to the detector window compared to the optical camera based system where a mirror and a lens are needed to capture an image. B. Replacement of the optical camera readout with the delay line anode helps to increase the sensitivity of the imaging system. C. Therefore the MCP based detector with the delay line anode is also better in terms of image acquisition time and overall ease of operation for tomography applications.

17 Neutron Image Sensor Description

18 Scintillator+CMOS X-Ray Image Sensor

19 Stages and Motion Control Equipments

20 Stages and Lab Jack Physical Properties Physical Parameter Micro step Size Resolution Speed Resolution Linear Stage Rotary Stage μm deg worm gear ratio X Y Stage mm/s 13.2 deg/s Up to 29 mm/s Z Axis Stage μm 0.40 mm 1.0 mm/s (Small Load) 0.5 mm/s (Maximum Load) Accuracy +/ 15 μm +/ 0.05 deg +/ 21 μm 5% Step acc. Travel Distance Load Capacity 300 mm 360 deg rotation mm 50 mm 200 N cm (Maximum Cantilever Load) 20 kg 10 kg 15 kg

21 Design of NXCT System (left) and Developed Experimental Set-up (Right)

22

23

24

25 Imaging setup in the basement of MSTR Operating room on the 2 nd floor of MSTR

26 Radiation Safety Audio/visual alarms in conjunction with the entrance door disconnect switch provide foolproof radiation safety for each experiment. These devices assure compliance with FDA CDRH safety requirements for radiation producing devices

27 System Control

28 GUI for NXCT Component Control

29 Neutron Sensor Image Display

30 Image Acquisition (x-ray) Memory Flash drive Wooden Pencil Borax in Plastic Vial Borosilicate Testtube

31 Image Acquisition (x-ray) Different Views of Rock Sample to Investigate Water Diffusion

32 Image Acquisition (x-ray) Simulated Phantom as a TRISO substitute

33 Image Acquisition (neutron & x-ray) (a) (b) Neutron (Left) and X-Ray (Right) Image of Borax in Vial

34 Image Acquisition (neutron & x-ray) (a) (b) Neutron (Left) and X-Ray (Right) Image of Memory Flash Card

35

36

37 Image Acquisition (neutron & x-ray) (a) (b) (c) Neutron X-ray Fused Neutron (Left) and X-Ray (Right) Image of Mechanical Pencil

38 Potential Applications of the Facility Mechanical testing of structural materials. Non-destructive evaluation of TRISO nuclear fuel particles. Particle tracking in complex flows using fluoroscopy techniques. Non-destructive evaluation of biomaterials such as artificial bones. Homeland-security applications.

39 Conclusion The construction and implementation of the NXCT imaging system at Missouri S&T is the first such method to be developed. This system will provide for great benefits across multiple disciplines and particularly in nondestructive evaluation. The concept of NXCT can be useful for concealed material detection, material characterization, investigation of complex geometries involving different atomic number materials and real time imaging for in-situ studies.

40 Neutron imaging has the ability to detect light atomic number materials, including typical explosive materials. One immediately obvious application would be during the scanning of airport baggage, especially lead-covered items that conceal plastic weapons or explosive materials. It has been shown that fusion of neutron and x-ray images provides for greater image clarity and usefulness. The many uses of NXCT system are still being determined and would allow for improved research in practically all engineering disciplines.

41 Acknowledgement Missouri S&T Nuclear Engineering Faculty: Dr. A. Kumar, Dr. G. Mueller, Dr. S. Usman, Dr. C. Castano, Dr. Ayodeji, Dr. X. Liu Advanced Radiation Computed Tomography Laboratory (ARTLAB) Research Group Reactor Staff: Bill Bonzer, Craig Reisner, Raymond Kendrick, Maureen Henry DOE General Infrastructure Support and partial support from CBTRR Missouri S&T

42 Thank you! QUESTIONS?

43

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Experimental study of beam hardening artefacts in photon counting breast computed tomography Experimental study of beam hardening artefacts in photon counting breast computed tomography M.G. Bisogni a, A. Del Guerra a,n. Lanconelli b, A. Lauria c, G. Mettivier c, M.C. Montesi c, D. Panetta a,

More information

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13 Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer

More information

Laue lens for Nuclear Medicine

Laue lens for Nuclear Medicine Laue lens for Nuclear Medicine PhD in Physics Gianfranco Paternò Ferrara, 6-11-013 Supervisor: prof. Vincenzo Guidi Sensors and Semiconductors Lab, Department of Physics and Earth Science, University of

More information

Radiation Strip Thickness Measurement Systems

Radiation Strip Thickness Measurement Systems Radiation Strip Thickness Measurement Systems During the past years we have increased our sales of radiometric Vollmer strip thickness measurement systems, i.e. X-ray or isotope gauges, dramatically. Now,

More information

Dynamic Neutron Imaging

Dynamic Neutron Imaging Wir schaffen Wissen heute für morgen Pierre Boillat Neutron Imaging & Activation Group (NIAG) and Electrochemistry Laboratory (LEC), Paul Scherrer Institute, Switzerland Dynamic Neutron Imaging PSI, 8.

More information

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster Jesse Garant, JG&A Metrology Center Traditional Metrology and Inspection Tactile Devices (Touch Probe)

More information

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS Frazier L. Bronson CHP Canberra Industries, Inc. 800 Research Parkway,

More information

Automatic and Objective Measurement of Residual Stress and Cord in Glass

Automatic and Objective Measurement of Residual Stress and Cord in Glass Automatic and Objective Measurement of Residual Stress and Cord in Glass GlassTrend - ICG TC15/21 Seminar SENSORS AND PROCESS CONTROL 13-14 October 2015, Eindhoven Henning Katte, ilis gmbh copyright ilis

More information

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM

More information

Synthetic Sensing: Proximity / Distance Sensors

Synthetic Sensing: Proximity / Distance Sensors Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,

More information

Cathode Ray Tube. Introduction. Functional principle

Cathode Ray Tube. Introduction. Functional principle Introduction The Cathode Ray Tube or Braun s Tube was invented by the German physicist Karl Ferdinand Braun in 897 and is today used in computer monitors, TV sets and oscilloscope tubes. The path of the

More information

Lecture 2 Macroscopic Interactions. 22.106 Neutron Interactions and Applications Spring 2010

Lecture 2 Macroscopic Interactions. 22.106 Neutron Interactions and Applications Spring 2010 Lecture 2 Macroscopic Interactions 22.106 Neutron Interactions and Applications Spring 2010 Objectives Macroscopic Interactions Atom Density Mean Free Path Moderation in Bulk Matter Neutron Shielding Effective

More information

An Quantitative Evaluation of the Canadian Forces New Radiology Inspection Systems for the Detection of Water Ingress in CF188 Flight Control Surfaces

An Quantitative Evaluation of the Canadian Forces New Radiology Inspection Systems for the Detection of Water Ingress in CF188 Flight Control Surfaces 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China An Quantitative Evaluation of the Canadian Forces New Radiology Inspection Systems for the Detection of Water Ingress in

More information

Fig.1. The DAWN spacecraft

Fig.1. The DAWN spacecraft Introduction Optical calibration of the DAWN framing cameras G. Abraham,G. Kovacs, B. Nagy Department of Mechatronics, Optics and Engineering Informatics Budapest University of Technology and Economics

More information

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems GE s Industrial X-ray and CT Forum, Cologne July 7 th 2015 Oliver Brunke GE Sensing & Inspection Technologies

More information

Single Electron Detection with the Large Volume Spherical Proportional Counter Ilias Savvidis

Single Electron Detection with the Large Volume Spherical Proportional Counter Ilias Savvidis Single Electron Detection with the Large Volume Spherical Proportional Counter Ilias Savvidis Collaboration S. Andriamonje, S. Aune, E. Bougamont, M. Chapelier, P. Colas, J. Derré, E. Ferrer, G. Gerbier,

More information

Modern Physics Laboratory e/m with Teltron Deflection Tube

Modern Physics Laboratory e/m with Teltron Deflection Tube Modern Physics Laboratory e/m with Teltron Deflection Tube Josh Diamond & John Cummings Fall 2010 Abstract The deflection of an electron beam by electric and magnetic fields is observed, and the charge

More information

Principles of Ion Implant

Principles of Ion Implant Principles of Ion Implant Generation of ions dopant gas containing desired species BF 3, B 2 H 6, PH 3, AsH 3, AsF 5 plasma provides positive ions (B 11 ) +, BF 2+, (P 31 ) +, (P 31 ) ++ Ion Extraction

More information

Fundamentals of Cone-Beam CT Imaging

Fundamentals of Cone-Beam CT Imaging Fundamentals of Cone-Beam CT Imaging Marc Kachelrieß German Cancer Research Center (DKFZ) Heidelberg, Germany www.dkfz.de Learning Objectives To understand the principles of volumetric image formation

More information

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950 HIGH PERFORMANCE MOBILE SURGICAL C-ARM 1K x 1k CCD Digital Camera System H.F. GENERATOR & ROTATING ANODE TUBE WITH DIGITAL WORKSTATION DESCRIPTION: Mobile Surgical C-arm systems are integrated with a triple

More information

A Polarimetry concept for the EDM experiment at COSY

A Polarimetry concept for the EDM experiment at COSY A Polarimetry concept for the EDM experiment at COSY Paul Maanen JEDI Collaboration Physics Institute III B, RWTH Aachen University DPG Frühjahrstagung March 27, 2015 Outline Introduction Detector concept

More information

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry Cyclotron Centre in Poland and 2D thermoluminescence dosimetry Jan Gajewski Institute of Nuclear Physics, Kraków, Poland Department of Radiation Dosimetry Nuclear Physics Institute Academy of Science of

More information

Coating Thickness and Composition Analysis by Micro-EDXRF

Coating Thickness and Composition Analysis by Micro-EDXRF Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing

More information

Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project

Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project U. Ewert, U.

More information

Atomic and Nuclear Physics Laboratory (Physics 4780)

Atomic and Nuclear Physics Laboratory (Physics 4780) Gamma Ray Spectroscopy Week of September 27, 2010 Atomic and Nuclear Physics Laboratory (Physics 4780) The University of Toledo Instructor: Randy Ellingson Gamma Ray Production: Co 60 60 60 27Co28Ni *

More information

Methods for analysis and visualization of industrial XCT data of fibre reinforced composites

Methods for analysis and visualization of industrial XCT data of fibre reinforced composites Methods for analysis and visualization of industrial XCT data of fibre reinforced composites Christoph Heinzl Team DI(FH) Michael Reiter Software development, simulation, dimensional measurement Andreas

More information

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General

More information

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW Qiang Lu Chapter 3. System Scanning Hardware Overview 79 Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW Since all the image data need in this research were collected from the highly modified AS&E 101ZZ system,

More information

Data. microcat +SPECT

Data. microcat +SPECT Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for

More information

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM João Antônio Palma Setti, j.setti@pucpr.br Pontifícia Universidade Católica do Paraná / Rua Imaculada

More information

Introduction to Imaging 3 Giulia Festa Università degli Studi di Roma Tor Vergata 27 September 2010 Contents Prompt gamma Activation Analysis (PGAA) Prompt Gamma Activation Imaging combined with Neutron

More information

Development of on line monitor detectors used for clinical routine in proton and ion therapy

Development of on line monitor detectors used for clinical routine in proton and ion therapy Development of on line monitor detectors used for clinical routine in proton and ion therapy A. Ansarinejad Torino, february 8 th, 2010 Overview Hadrontherapy CNAO Project Monitor system: Part1:preliminary

More information

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Measurement of Charge-to-Mass (e/m) Ratio for the Electron Measurement of Charge-to-Mass (e/m) Ratio for the Electron Experiment objectives: measure the ratio of the electron charge-to-mass ratio e/m by studying the electron trajectories in a uniform magnetic

More information

Lectures about XRF (X-Ray Fluorescence)

Lectures about XRF (X-Ray Fluorescence) 1 / 38 Lectures about XRF (X-Ray Fluorescence) Advanced Physics Laboratory Laurea Magistrale in Fisica year 2013 - Camerino 2 / 38 X-ray Fluorescence XRF is an acronym for X-Ray Fluorescence. The XRF technique

More information

Information about the T9 beam line and experimental facilities

Information about the T9 beam line and experimental facilities Information about the T9 beam line and experimental facilities The incoming proton beam from the PS accelerator impinges on the North target and thus produces the particles for the T9 beam line. The collisions

More information

2 Absorbing Solar Energy

2 Absorbing Solar Energy 2 Absorbing Solar Energy 2.1 Air Mass and the Solar Spectrum Now that we have introduced the solar cell, it is time to introduce the source of the energy the sun. The sun has many properties that could

More information

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC CHAPTER 5 QC Test For Radiographic Equipment Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC Lesson Outcomes Describe the objectives of each QC test done.(importance)

More information

REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH. REGULATORY GUIDE 8.4 (Draft was issued as DG-8036, dated April 2010)

REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH. REGULATORY GUIDE 8.4 (Draft was issued as DG-8036, dated April 2010) U.S. NUCLEAR REGULATORY COMMISSION June 2011 Revision 1 REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH REGULATORY GUIDE 8.4 (Draft was issued as DG-8036, dated April 2010) PERSONNEL MONITORING

More information

Proton tracking for medical imaging and dosimetry

Proton tracking for medical imaging and dosimetry Proton tracking for medical imaging and dosimetry J.Taylor, P.Allport, G.Casse For the PRaVDA Consortium 1 Background and motivation - What is the PRaVDA experiment? - Why are we using Monte Carlo? GEANT4

More information

National Performance Evaluation Facility for LADARs

National Performance Evaluation Facility for LADARs National Performance Evaluation Facility for LADARs Kamel S. Saidi (presenter) Geraldine S. Cheok William C. Stone The National Institute of Standards and Technology Construction Metrology and Automation

More information

EDXRF of Used Automotive Catalytic Converters

EDXRF of Used Automotive Catalytic Converters EDXRF of Used Automotive Catalytic Converters Energy Dispersive X-Ray Fluorescence (EDXRF) is a very powerful technique for measuring the concentration of elements in a sample. It is fast, nondestructive,

More information

Overview of Nuclear Detection Needs for Homeland Security. Abstract

Overview of Nuclear Detection Needs for Homeland Security. Abstract Overview of Nuclear Detection Needs for Homeland Security Timothy E. Valentine * Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, Tennessee, 37831, USA Abstract The need for advanced and improved

More information

Instruction Sheet 554 828

Instruction Sheet 554 828 08/13-W07-Hund Instruction Sheet 554 828 X-ray image sensor (554 828) Precision slide X-ray image sensor (554 829) Software Computed Tomography Pro (554 820) Sensor head on precision slide with USB module

More information

Purchasing a cardiac CT scanner: What the radiologist needs to know

Purchasing a cardiac CT scanner: What the radiologist needs to know Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London maria.lewis@stgeorges.nhs.uk CT scanner development Slice wars 1998 Increased z-coverage

More information

Reflection and Refraction

Reflection and Refraction Equipment Reflection and Refraction Acrylic block set, plane-concave-convex universal mirror, cork board, cork board stand, pins, flashlight, protractor, ruler, mirror worksheet, rectangular block worksheet,

More information

Cargo Container X-ray Inspection Systems

Cargo Container X-ray Inspection Systems Hitachi Review Vol. 53 (2004), No. 2 97 Cargo Container X-ray Inspection Systems OVERVIEW: Container inspection is categorized into three stages. In the initial stage, large-size X-ray DR (digital radiography)

More information

Remote RadEye Product Family

Remote RadEye Product Family Remote RadEye Product Family Overview The Remote RadEye x-ray camera provides the ultimate flexibility in design and product options for your complex imaging applications. Our unique camera design separates

More information

V K Raina. Reactor Group, BARC

V K Raina. Reactor Group, BARC Critical facility for AHWR and PHWRs V K Raina Reactor Group, BARC India has large reserves of Thorium Critical facility Utilisation of Thorium for power production is a thrust area of the Indian Nuclear

More information

LA-UR- Title: Author(s): Submitted to: Approved for public release; distribution is unlimited.

LA-UR- Title: Author(s): Submitted to: Approved for public release; distribution is unlimited. LA-UR- Approved for public release; distribution is unlimited. Title: Author(s): Submitted to: Los Alamos National Laboratory, an affirmative action/equal opportunity employer, is operated by the University

More information

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser V.Nassisi #, G.Caretto #, A. Lorusso #, D.Manno %, L.Famà %, G.Buccolieri %, A.Buccolieri %, U.Mastromatteo* # Laboratory of Applied

More information

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical

More information

A Beam Halo Monitor Based on Adaptive Optics. Courtesy of Dr Carsten P. Welsch AB/BI/PM

A Beam Halo Monitor Based on Adaptive Optics. Courtesy of Dr Carsten P. Welsch AB/BI/PM A Beam Halo Monitor Based on Adaptive Optics Courtesy of Dr Carsten P. Welsch AB/BI/PM Outline 1. Beam Halo Measurements Whydowecare? How to do the measurement? Introduction to CID technology 2. Core-masking

More information

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter T.M.Taha Radiation Protection Department, Nuclear Research Center, Atomic Energy Authority, Cairo.P.O.13759 Egypt.

More information

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit I-Max Touch Range PAN / CEPH / 3D digital panoramic unit Evolutive 3 in 1 panoramic unit 3D A new dimension for a complete diagnosis I-Max Touch 3D Evolutive, simple, fast The panoramic unit realizes complete

More information

DICOM Correction Item

DICOM Correction Item Correction Number DICOM Correction Item CP-626 Log Summary: Type of Modification Clarification Rationale for Correction Name of Standard PS 3.3 2004 + Sup 83 The description of pixel spacing related attributes

More information

VEHICLE TRACKING USING ACOUSTIC AND VIDEO SENSORS

VEHICLE TRACKING USING ACOUSTIC AND VIDEO SENSORS VEHICLE TRACKING USING ACOUSTIC AND VIDEO SENSORS Aswin C Sankaranayanan, Qinfen Zheng, Rama Chellappa University of Maryland College Park, MD - 277 {aswch, qinfen, rama}@cfar.umd.edu Volkan Cevher, James

More information

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters

More information

DHS National Technical Nuclear Forensics Program FY 10 Summary Report: Graduate Mentoring Assistance Program (GMAP)

DHS National Technical Nuclear Forensics Program FY 10 Summary Report: Graduate Mentoring Assistance Program (GMAP) INL/EXT-11-23605 DHS National Technical Nuclear Forensics Program FY 10 Summary Report: Graduate Mentoring Assistance Program (GMAP) Martha A. Finck October 2011 The INL is a U.S. Department of Energy

More information

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis David Bernard & Steve Ainsworth Dage Precision Industries Abstract Non-destructive testing during the manufacture of

More information

Gamma and X-Ray Detection

Gamma and X-Ray Detection Gamma and X-Ray Detection DETECTOR OVERVIEW The kinds of detectors commonly used can be categorized as: a. Gas-filled Detectors b. Scintillation Detectors c. Semiconductor Detectors The choice of a particular

More information

Physics testing of image detectors

Physics testing of image detectors Physics testing of image detectors Parameters to test Spatial resolution Contrast resolution Uniformity/geometric distortion Features and Weaknesses of Phantoms for CR/DR System Testing Dose response/signal

More information

APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS

APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS V.A. Popovich 1, W. Verwaal 2, M. Janssen 1, I. J. Bennett 3, I.M.Richardson 1, 1. Delft University of Technology, Department of Materials

More information

THE EFFECTS OF TEMPERATURE VARIATION ON SINGLE-LENS-REFLEX DIGITAL CAMERA CALIBRATION PARAMETERS

THE EFFECTS OF TEMPERATURE VARIATION ON SINGLE-LENS-REFLEX DIGITAL CAMERA CALIBRATION PARAMETERS Coission V Symposium, Newcastle upon Tyne, UK. 2010 THE EFFECTS OF TEMPERATURE VARIATION ON SINGLE-LENS-REFLEX DIGITAL CAMERA CALIBRATION PARAMETERS M. J. Smith *, E. Cope Faculty of Engineering, The University

More information

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm Proceedings of the Ninth EGS4 Users' Meeting in Japan, KEK Proceedings 200-22, p.5-8 MONTE CARLO SIMULATION ANALYSIS OF BACKSCATTER FACTOR FOR LOW-ENERGY X-RAY K. Shimizu, K. Koshida and T. Miyati Department

More information

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques Recognition I will take this opportunity to recognize and thank the following people s contributions to this presentation. Considerations for: Diagnostic Radiology, Nuclear Medicine and, Oncology M. S.

More information

Performance testing for Precision 500D Classical R/F System

Performance testing for Precision 500D Classical R/F System Performance testing for Precision 500D Classical R/F System John M. Boudry, Ph.D. Image Quality Systems Engineer GE Healthcare Technologies Outline System background Image Quality Signature Test (IQST)

More information

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment K. Litfin, A. Batta, A. G. Class,T. Wetzel, R. Stieglitz Karlsruhe Institute of Technology Institute for Nuclear and Energy

More information

Quality Control on Aerospace Components Using Handheld X-ray Fluorescence (XRF)

Quality Control on Aerospace Components Using Handheld X-ray Fluorescence (XRF) International Workshop SMART MATERIALS, STRUCTURES & NDT in AEROSPACE Conference NDT in Canada 2011 2-4 November 2011, Montreal, Quebec, Canada Quality Control on Aerospace Components Using Handheld X-ray

More information

X-ray Tomography in Industrial Metrology

X-ray Tomography in Industrial Metrology verlag moderne industrie X-ray Tomography in Industrial Metrology Precise, Economical and Universal Ralf Christoph and Hans Joachim Neumann This book was produced with technical collaboration of Werth

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MAMMOGRAPHY) SECTION

More information

Laser safety in the lab

Laser safety in the lab Laser safety in the lab Laser safety potential dangers to health classification of lasers according to these dangers classifications of the lasers in our lab how to protect ourselves and our colleagues

More information

Automated Pose Determination for Unrestrained, Non-anesthetized Small Animal Micro-SPECT and Micro-CT Imaging

Automated Pose Determination for Unrestrained, Non-anesthetized Small Animal Micro-SPECT and Micro-CT Imaging Automated Pose Determination for Unrestrained, Non-anesthetized Small Animal Micro-SPECT and Micro-CT Imaging Shaun S. Gleason, Ph.D. 1, James Goddard, Ph.D. 1, Michael Paulus, Ph.D. 1, Ryan Kerekes, B.S.

More information

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY 243 CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY B. Chyba, M. Mantler, H. Ebel, R. Svagera Technische Universit Vienna, Austria ABSTRACT The accurate characterization of the spectral distribution

More information

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration. Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration. Gary H. Kramer, Linda C. Burns and Steven Guerriere Human Monitoring Laboratory, Radiation

More information

Digital Image Correlation Technique Applied to Laminated Glass Plates Under Free Air Blast Loading

Digital Image Correlation Technique Applied to Laminated Glass Plates Under Free Air Blast Loading FACULTY OF ENGINEERING & ARCHITECTURE Digital Image Correlation Technique Applied to Laminated Glass Plates Under Free Air Blast Loading Sam Van Dam 1, Joren Pelfrene 1 & Wim Van Paepegem 1 Bachir Belkassem

More information

The professional for your diagnostics.

The professional for your diagnostics. CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS DIGITAL PANORAMIC X-RAY MADE SIMPLE The professional for your diagnostics. System concept ORTHOPHOS XG 5 completes the next

More information

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.

More information

h e l p s y o u C O N T R O L

h e l p s y o u C O N T R O L contamination analysis for compound semiconductors ANALYTICAL SERVICES B u r i e d d e f e c t s, E v a n s A n a l y t i c a l g r o u p h e l p s y o u C O N T R O L C O N T A M I N A T I O N Contamination

More information

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study Feasibility Study of Neutron Dose for Real Time Image Guided Proton Therapy: A Monte Carlo Study Jin Sung Kim, Jung Suk Shin, Daehyun Kim, EunHyuk Shin, Kwangzoo Chung, Sungkoo Cho, Sung Hwan Ahn, Sanggyu

More information

Nuclear Physics. Nuclear Physics comprises the study of:

Nuclear Physics. Nuclear Physics comprises the study of: Nuclear Physics Nuclear Physics comprises the study of: The general properties of nuclei The particles contained in the nucleus The interaction between these particles Radioactivity and nuclear reactions

More information

In-Sight Hardware specifications

In-Sight Hardware specifications specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited

More information

Industrial X-ray for Nondestructive Testing Unrestricted Siemens AG 2014. All rights reserved

Industrial X-ray for Nondestructive Testing Unrestricted Siemens AG 2014. All rights reserved Overview of X-ray Technology and Competence offered by Corporate Technology Industrial X-ray for Nondestructive Testing Nondestructive Testing (NDT) with X-rays: Our offer at a glance High-tech X-ray lab

More information

Motion Activated Camera User Manual

Motion Activated Camera User Manual Brinno MAC200 User Manual Last Modified on 12/23/2015 7:51 pm EST Motion Activated Camera User Manual www.brinno.com Register@online http://www.brinno.com/support/register.html contact us: customerservice@brinno.com

More information

Powder diffraction and synchrotron radiation

Powder diffraction and synchrotron radiation Powder diffraction and synchrotron radiation Gilberto Artioli Dip. Geoscienze UNIPD CIRCe Center for Cement Materials single xl diffraction powder diffraction Ideal powder Powder averaging Textured sample

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

Introduction to the Monte Carlo method

Introduction to the Monte Carlo method Some history Simple applications Radiation transport modelling Flux and Dose calculations Variance reduction Easy Monte Carlo Pioneers of the Monte Carlo Simulation Method: Stanisław Ulam (1909 1984) Stanislaw

More information

Experiment: Static and Kinetic Friction

Experiment: Static and Kinetic Friction PHY 201: General Physics I Lab page 1 of 6 OBJECTIVES Experiment: Static and Kinetic Friction Use a Force Sensor to measure the force of static friction. Determine the relationship between force of static

More information

Wir schaffen Wissen heute für morgen

Wir schaffen Wissen heute für morgen Diffractive optics for photon beam diagnostics at hard XFELs Wir schaffen Wissen heute für morgen PSI: SLAC: ESRF: SOLEIL: APS: SACLA: EuroXFEL C. David, S. Rutishauser, P. Karvinen, Y. Kayser, U. Flechsig,

More information

3-D Printing Artificial Reservoir Rocks to Test Their Petrophysical Properties*

3-D Printing Artificial Reservoir Rocks to Test Their Petrophysical Properties* 3-D Printing Artificial Reservoir Rocks to Test Their Petrophysical Properties* Sergey Ishutov 1 and Franciszek Hasiuk 1 Search and Discovery Article #41427 (2014) Posted August 29, 2014 *Adapted from

More information

Mobile Robot FastSLAM with Xbox Kinect

Mobile Robot FastSLAM with Xbox Kinect Mobile Robot FastSLAM with Xbox Kinect Design Team Taylor Apgar, Sean Suri, Xiangdong Xi Design Advisor Prof. Greg Kowalski Abstract Mapping is an interesting and difficult problem in robotics. In order

More information

Digital vs. Analogue Control Systems

Digital vs. Analogue Control Systems Digital vs. Analogue Control Systems Presented at the 2011 Annual Meeting of the American College of Medical Physics, Chattanooga, TN, May 1, 2011 Ivan A. Brezovich, PhD, Dept. of Rad Onc, Univ of Alabama

More information

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation Outline MAE 493R/593V- Renewable Energy Devices Solar Energy Electromagnetic wave Solar spectrum Solar global radiation Solar thermal energy Solar thermal collectors Solar thermal power plants Photovoltaics

More information

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G Auto-Levelling Rotary Laser Level RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G 77-496 / 77-429 / 77-439 / 77-497 / 77-427/ 77-441 Please read these instructions before operating the product Auto-Levelling

More information

How To Fuse A Point Cloud With A Laser And Image Data From A Pointcloud

How To Fuse A Point Cloud With A Laser And Image Data From A Pointcloud REAL TIME 3D FUSION OF IMAGERY AND MOBILE LIDAR Paul Mrstik, Vice President Technology Kresimir Kusevic, R&D Engineer Terrapoint Inc. 140-1 Antares Dr. Ottawa, Ontario K2E 8C4 Canada paul.mrstik@terrapoint.com

More information

CBERS Program Update Jacie 2011. Frederico dos Santos Liporace AMS Kepler liporace@amskepler.com

CBERS Program Update Jacie 2011. Frederico dos Santos Liporace AMS Kepler liporace@amskepler.com CBERS Program Update Jacie 2011 Frederico dos Santos Liporace AMS Kepler liporace@amskepler.com Overview CBERS 3 and 4 characteristics Differences from previous CBERS satellites (CBERS 1/2/2B) Geometric

More information

Interference. Physics 102 Workshop #3. General Instructions

Interference. Physics 102 Workshop #3. General Instructions Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by

More information

Filters for Digital Photography

Filters for Digital Photography Filters for Digital Photography LICHTFILTER Whether for analog or Digital Photography: The best results are achieved by using correction filters - not by digitally enhancing in a software program as once

More information

Automation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1

Automation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Automation of a CT Acquisition: A System-based User-Support More Info at Open Access Database

More information