MAX-TEMP CTHB / CTHT Centrifugal F Rated Fans

Size: px
Start display at page:

Download "MAX-TEMP CTHB / CTHT Centrifugal F Rated Fans"

Transcription

1 ROOF MOUNTD FANS MAX-TMP TH / THT entrifugal F Rated Fans Range of centrifugal roof mounted fans in horizontal discharge format, designed for smoke extraction in fire conditions and certified F ( marked) (1). All models are suitable for Approved to N standard ertificate number 0370-PD-0347 air stream temperature up to 120º. ases are manufactured from galvanised sheet steel and cowls are manufactured from spun aluminium. All models incorporate bird-proof guard. ONTINUOUS operation Available, depending upon the model, with single or three phase motors in 4, 6, 8, 4/8 or 6/12 poles. (1) xcept 140, 180 and 200 models. Motors All motors are IP55, lass F and equipped with ball bearings greased for life. lectrical supply: Single phase 230V-50Hz. Three phase 400V-50Hz. (See characteristics chart). MAX-TMP TH/THT Speed controllable by Voltage, up to the 400 model. Adjustable frecuency drive from 450 to 710. When is using a speed controller, the electrical installation must be equipped with a secu- Smoke extract ONTINUOUS rity system which allows the maximum speed of the fans in cas of fire. Additional information 140, 180, 200 and 225 models are specially recommended for extracting smoke from the fireplaces. A P P L I A T I O N S Only F at maximum speed fan. Warehouses Workshops ommercial premises Offices ar Parks Industrial and commercial kitchens asy to install Self cooling system ird-proof guard ackward curved centrifugal impellers Supports easing the installation on the roof Special design in order to cool the motor and to extend the life of the assembly To prevent accumulation of dirt. Models up to 400 are manufactured from galvanised steel sheet. Models from 450 to 630 are manufactured in sheet steel protected against corrosion by cataforesis primer and black polyester paint finish 309

2 MAX-TMP TV/TVT ROOF MOUNTD FANS MAX-TMP TV / TVT entrifugal F Rated Fans Models configuration 140 to 400 A P P L I A T I O N S Approved to N standard ertificate number 0370-PD-0347 ONTINUOUS operation Models configuration 450 to 710 ooling duct Range of centrifugal roof mounted fans in vertical discharge format, designed for smoke extraction in fire conditions and certified F ( marked) (1). All models are suitable for air stream temperature up to 120º. ases are manufactured from galvanised sheet steel and cowls are manufactured from spun aluminium. All models incorporate bird-proof guard. Available, depending upon the model, with single or three phase motors in 4, 6, 8, 4/8 or 6/12 poles. (1) xcept 140, 180 and 200 models. Motors All motors are IP55, lass F and equipped with ball bearings greased for life. lectrical supply: Single phase 230V-50Hz. Three phase 400V-50Hz. (See characteristics chart). Speed controllable by Voltage, up to the 400 model. Adjustable frecuency drive from 450 to 710. When is using a speed controller, the electrical installation must be equipped with a security system which allows the maximum speed of the fans in cas of fire. Additional information 140, 180, 200 and 225 models are specially recommended for extracting smoke from the fireplaces. Warehouses Workshops ommercial premises Offices Smoke extract ONTINUOUS ar Parks Industrial and commercial kitchens asy to install Self cooling system nables the motor cooling when Only F at maximum speed fan. the fan is extracting air at an extremely high temperature ackward curved centrifugal impellers ird-proof guard Supports easing the installation on the roof Special design in order to cool the motor and to extend the life of the assembly To prevent accumulation of dirt. Models up to 400 are manufactured from galvanised steel sheet. Models from 450 to 630 are manufactured in sheet steel protected against corrosion by cataforesis primer and black polyester paint finish 310

3 Technical characteristics for models with horizontal discharge TH/ THT efore installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency etc) match those of the intended electrical supply. Model 4 POLS SINGL PHAS 6 POLS SINGL PHAS 4 POLS THR PHAS 6 POLS THR PHAS 8 POLS THR PHAS 2 SPD THR PHAS Speed (r.p.m.) Maximum absorbed power (W) Maximum absorbed current (A) Maximum air volume Sound pressure level* at 2/3 max (d(a)) at 230 V at 400 V (m 3 /h) Inlet Outlet Weight * The ratings of sound levels are pressure values measured in d(a) at 1,5 m at 2/3 max. **Three phase speed controllers (RMT) are suitable for 400V. ***Models with adjustable frecuency drives need to mount motors version 22. (Kg) Speed controllable (**) (***) TH/ , ,5 R-1N TH/ , R-1N TH/ , ,2 R-1N TH/ , R-1N TH/ , R-2,5N TH/ , R-5 TH/ , ,5 R-10 TH/ , ,2 R-1N TH/ , R-1N TH/ , R-1N TH/ , R-1N TH/ , ,5 R-2,5N THT/ , ,5 RMT-1,5 THT/ , RMT-1,5 THT/ , ,2 RMT-1,5 THT/ , RMT-1,5 THT/ , RMT-1,5 THT/ , RMT-2,5 THT/ , ,5 RMT-2,5 THT/ , VFK-48 THT/ , ,2 RMT-1,5 THT/ , RMT-1,5 THT/ , RMT-1,5 THT/ , RMT-1,5 THT/ , ,5 RMT-1,5 THT/ , VFK-45 THT/ , VFK-45 THT/ , VFK-48 THT/ , VFTM-TRI 4 THT/ , VFTM TRI 7,5 THT/ , VFK-45 THT/ , VFK-45 THT/ , VFK-45 THT/ , VFK-48 THT/ , VFK-48 THT/4/ / /70 0,3/0,2 2100/ /38 59/44 17 THT/4/ / /230 1,1/0,9 4900/ /45 66/51 33 THT/4/ / /260 1,8/1,0 7000/ /52 73/58 44 THT/4/ / /600 6,1/2, / /55 76/61 69 THT/6/ / /190 2/1 6900/ /44 66/51 72 THT/6/ / /430 4,5/2, / /48 69/ THT/6/ / /640 5,6/2, / /51 73/ THT/6/ / /730 8,1/2, / /55 76/ THT/6/ / /850 14,1/5, / /62 83/ MAX-TMP TH/THT - TV/TVT 311

4 Technical characteristics for models with vertical discharge TV/ TVT efore installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency etc) match those of the intended electrical supply. MAX-TMP TH/THT - TV/TVT Model 4 POLS SINGL PHAS 6 POLS SINGL PHAS 4 POLS THR PHAS 6 POLS THR PHAS 8 POLS THR PHAS 2 SPD THR PHAS Speed (r.p.m.) Maximum absorbed power (W) Maximum absorbed current (A) Maximum air volume Sound pressure level* at 2/3 max (d(a)) at 230 V at 400 V (m 3 /h) Inlet Outlet Weight (Kg) Speed controllable (**) (***) TV/ , R-1N TV/ , ,5 R-1N TV/ , R-1N TV/ , ,8 R-1N TV/ , R-2,5N TV/ , R-5 TV/ , R-10 TV/ , R-1N TV/ , ,8 R-1N TV/ , R-1N TV/ , R-1N TV/ , R-2,5N TVT/ , RMT-1,5 TVT/ , ,5 RMT-1,5 TVT/ , RMT-1,5 TVT/ , ,8 RMT-1,5 TVT/ , RMT-1,5 TVT/ , RMT-2,5 TVT/ , RMT-2,5 TVT/ , VFK-45 TVT/ , RMT-1,5 TVT/ , ,8 RMT-1,5 TVT/ , RMT-1,5 TVT/ , RMT-1,5 TVT/ , RMT-1,5 TVT/ , VFK-45 TVT/ , VFK-45 TVT/ , VFK-48 TVT/ , VFTM-TRI 4 TVT/ , VFTM TRI 7,5 TVT/ , VFK-45 TVT/ , VFK-45 TVT/ , VFK-45 TVT/ , VFK-45 TVT/ , VFK-48 TVT/4/ / /70 0,3/0,2 2100/ /38 59/44 17 TVT/4/ / /230 1,1/0,9 4200/ /45 64/49 40 TVT/4/ / /260 1,3/1,0 6250/ /52 70/55 52 TVT/4/ / /600 6,1/2,5 9850/ /55 74/59 77 TVT/6/ / /190 2/1 5900/ /44 63/48 80 TVT/6/ / /430 4,5/2,2 9500/ /47 66/ TVT/6/ / /640 5,6/2, / /51 70/ TVT/6/ / /730 8,1/2, / /54 74/ TVT/6/ / /435 14/5, / /60 72/ * The ratings of sound levels are pressure values measured in d(a) at 1,5 m at 2/3 max. **Three phase speed controllers (RMT) are suitable for 400V. ***Models with adjustable frecuency drives need to mount motors version

5 Performance curves Horizontal discharge models = Air volume in, m 3 /h and m 3 /s. = Static pressure in and Pa. Dry air at 20º and 760 mmhg. Performance data in accordance with ISO 5801 and AMA Standards. THT/TH - 4 poles THT/TH - 4 poles MAX-TMP TH/THT - TV/TVT THT/TH - 6 poles THT - 6 poles THT/TH - 8 poles THT - 12 poles (2 speed motors 6/12) The values are sound pressure levels measured at 1,5 m, in free field conditions, at the fan inlet side. 313

6 Performance curves Vertical discharge models = Air volume in, m 3 /h and m 3 /s. = Static pressure in and Pa. Dry air at 20º and 760 mmhg. Performance data in accordance with ISO 5801 and AMA Standards. MAX-TMP TH/THT - TV/TVT TVT/TV - 4 poles TVT/TV - 4 poles TVT/TV - 6 poles TVT/TV - 6 poles Pa mmcda TVT/TV - 8 poles TVT - 12 poles (2 speed motors 6/12) Pa mmcda 314 The values are sound pressure levels measured at 1,5 m, in free field conditions, at the fan inlet side.

7 Acoustic characteristics Sound power spectrum To obtain the sound power spectrum, subtract the correction value shown in the following chart from the value in the technical characteristics table: HORIZONTAL DISHARG Frequency bands in Hz max 2,0 7,5 11,0 11,0 9,0 6,0 0,5 AT TH DISHARG 2/3 max -0,5 3,5 5,5 5,5 3,5 0,5-4,5 1/3 max -2,5 1,5 3,5 3,5 1,5-1,5-6,5 max 5,5 9,0 11,5 11,0 10,0 7,5 3,5 AT TH INLT 2/3 max 2,5 5,0 6,0 4,5 1,5-2,5-8,6 1/3 max 0,5 3,0 4,0 2,5-0,5-4,5-10,5 VRTIAL DISHARG Frequency bands in Hz max 3,0 8,0 11,5 11,5 8,0 1,5-8,0 AT TH DISHARG 2/3 max 0,5 4,5 6,5 5,0 1,5-3,0-10,0 1/3 max -1,5 2,5 4,5 3,0-0,5-5,0-12,0 max 4,5 9,0 10,5 8,5 6,5 5,5 3,0 AT TH INLT 2/3 max 3,0 5,0 6,0 4,5 1,0-3,0-9,5 1/3 max 1,0 3,0 4,0 2,5-1,0-5,0-11,5 MAX-TMP TH/THT - TV/TVT Sound power spectrum The sound pressure spectrum, at a distance d, can be obtained by subtracting from each frequency band of the power spectrum, the correction value shown in the following chart: Dimensions (mm) Ø AH DISTAN (d) 1m 1,5m 4m 6m 10m 15m 20m 30m ORRTION (d) 11 14, Model of fan Ø AH Ø AV H V Ø D* Ø F holes H Ø F Ø D Ø AV holes Ø F V Ø D * Nominal accessories diameter. 315

8 Mounting accessories MAX-TMP TH/THT - TV/TVT Sealing Frame JMS Model JMS A F ➀ For mounting a roof fan on an up stand or base. A Supplied with screws and gasket for a complete weatherproof seal ➁ ➃ Flat Roof Up stand JS For mounting a fan on a flat roof without up stands. For use on horizontal roofs. Internal insulation to prevent condensation. Supplied with screws and gasket for a complete weather seal. Accessory Adapter Plate JPA Used when mounting the accessories (JA, JR, JA). Allows the fan to be disconnected from the upstand without having to remove the duct. 300 n x t F Ø D H A G Model JS A G Model JPA Ø D nxt Ø H xM xM xM xM xM xM xM ➄ ackdraft Shutter JA Prevents backdraft when the fan is not operating. To be mounted at the fan inlet with the JPA plate. F Ø J Ø H Ø D Model JA Ø D F Ø H Ø J N N N N N ➅ Flange JR For use when circular connection is required directly to the fan. To be mounted at the fan inlet with the JPA plate or fixed directly to the fan base (rivets or screws not supplied). Ø J Ø H Ø D Model JR Ø D Ø H Ø J ➆ Flexible oupling JA Reduces the transmission of vibrations when the duct is connected directly to the fan. To be mounted at the fan inlet with JPA plate. Model JA Ø D Ø H Ø J ➇ Adapter For ircular Duct J For use when fitting the models up to 400, directly to a spirally wound circular duct. L Model J Ø Ø Ø D L

9 ➈ I support base for inclined curb mounted installations To ensure a proper installation of the MAXTMP roof fan it is essential to specify the roof pitch angle and the distance between the roof beam profiles. ➂ Viewed VISTO in POR A direction A d: Distance between the roof beam profiles a: Roof pitch angle (curb) Acoustic Up Stand JAA Reduces in duct and radiated noise. For use when mounting a fan on a flat roof without up stands. Supplied with screws and gasket for a complete weather seal. d 50 A a I I I I I I I Mod. JAA A Ø D (M) H G (MI0) (MI2) (MI2) (MI2) (MI4) (MI4) MAX-TMP TH/THT - TV/TVT (MI4) STANDARD MOUNTING RVRS MOUNTING STANDARD MOUNTING WITH ASSORIS RVRS MOUNTING WITH ASSORIS Acoustic attenuation in d(a) at the corresponding frequency band in Hz JAA Attenuator pressure drops Model JAA JAA JAA JAA JAA JAA JAA mm m 3/h 317

10 Installation MAX-TMP TH/THT - TV/TVT Model of fan ➀ Sealing frame ➁ Flat roof insulated up stand ➂ Acoustic up stand ➃ Accessory adapter plate ➄ ack draft shutter ➅ Flange with spigot ➆ Flexible coupling ➇ ircular adapter ➈ Support base for inclined curb mounted installations JMS-300 JS-300 JAA-300 JPA-300 JA-300 JR-300 JA-300 J-300 I-3 JMS-435 JS-435 JAA-435 JPA-435 JA-435 JR-435 JA-435 J-435 I-4 JMS-560 JS-560 JAA-560 JPA-560 JA-560 JR-560 JA-560 J-560 I JMS-630 JS-630 JAA-630 JPA-630 JA-630 JR-630 JA-630 J-630 I JMS-710 JS-710 JAA-710 JPA-710 JA-710 JR-710 JA I ➀ or ➃ ➁ or ➂ or ➈ ➇ ➄ ➆ ➅ JMS-905 JS-905 JAA-905 JPA-905 JA-905 JR-905 JA I-9 JMS-1100 JS-1100 JAA-1100 JPA-1100 JA-1100 JR-1100 JA I-11 lectrical accessories R Single phase electronic speed controllers. For use with the single phase roof fans. R-5 / R-10 Single phase electronic speed controllers. For use with single phase roof fans. RM / RMT Auto transformer speed controllers. For single phase and three phase roof fans models from 140 to 400. On/ Off lectrical isolation switch Switch On/ Off 5P (1 speed motor) Switch On/ Off 8P (2 speed motor). OM D/S Switch To connect three phase fans with 400 V motor. For three phase roof fans models from 140 to 400. VFK IP65 Adjustable frequency drives for three phase motors from 0,37 to 4 kw. VFTM IP54 Adjustable frequency drive for three phase motors from 0,37 to 15 kw. 318

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

TFSR & TFSK Roof Fans

TFSR & TFSK Roof Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof

More information

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8

More information

Surface Technology. Centrifugal Fan GMD

Surface Technology. Centrifugal Fan GMD Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient! Bathroom and toilet extract fans SILENT-100 BATHROOM EXTRACT FANS SILENT-100 Series SILVER versions The SILENT-100 CZ and CRZ can be supplied Range of axial extractors with airflow rates of approx. 95

More information

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation RFHD ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d According EU Regulation free RFHD Centrifugal roof fans with horizontal outlet and ATEX Ex d certification Centrifugal roof fans with

More information

Air Comfort. Technical Catalogue > Roof Fan STOF

Air Comfort. Technical Catalogue > Roof Fan STOF Air Comfort Technical Catalogue > Roof Fan STOF Roof_fan_stof_GB_2014.03.06.indd 1 2014-03-06 13:33 Contents ROOFMASTER - STOF vertical...3 Performance Data...4 Performance Table...7 Product and Electrical

More information

SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer. PART 1 GENERAL SECTION 23 34 13 HVAC FANS 1.01 SUMMARY A. Section Includes: 1. Exhaust fans. 2. Transfer fans. B. Related Documents: 1. Drawings and general provisions of the Contract, including General

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

O-I DUBI PLANT FANS Quotation Spec Data & Specifications TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement

More information

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series SILENT-1 Series Range of axial extractors with airflow rates of 85 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow

More information

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100 CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL

More information

ICQ Series - square centrifugal

ICQ Series - square centrifugal product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Standard offering (pumps)

Standard offering (pumps) MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

Application. Design. Structure. Acoustics

Application. Design. Structure. Acoustics Application The SMART fans are designed for general ventilation of buildings. They are meant for forwarding dry air of maximum temperature + C, and dustiness not exceeding,3 g/m3, without viscous, aggressive

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

FAN & BLOWER CENTRIFUGAL FANS

FAN & BLOWER CENTRIFUGAL FANS FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair systemair Disclose the secret

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings SWANTM WTW Linear slot air diffusers of wall-to-wall design for ceilings Quick facts Wall-to-wall installation Diffuser face of light aluminium design 2, 3 or slots Horizontal/vertical air distribution

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

AC axial fans A series

AC axial fans A series fans series Technology ccessories E-SYSTEMS ESM Q-motor General information K series E axial E axial fans series fans fans, series Ø 00 - Ø 350 58 57 ontacts fans series, Ø 00 Material: Guard grille: Steel,

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

EC medium pressure axial fans. The effi cient system solution.

EC medium pressure axial fans. The effi cient system solution. EC medium pressure axial fans. The effi cient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly effi cient GreenTech EC technology is now available for

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean

More information

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example: VSKA are supply air diffusers designed for ceiling mounting. The design of the air deflectors and discharge outlets causes the air discharged by the diffuser to mix with the air in the premises (high induction

More information

BASIS RANGE TMB SERIES

BASIS RANGE TMB SERIES BASIS RANGE SERIES magnetic driven pumps BASIS The pumps belong to Argal s BASIS range and feature, single stage, centrifugal impeller and magnetic drive. The range of pumps includes five models to deliver

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06 SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz

More information

Chapter 3.5: Fans and Blowers

Chapter 3.5: Fans and Blowers Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB OVERVIEW TYPE: GGB All composite construction Rigid extruded upvc aerofoil blade section Integral blade seals for low leakage operation Individual blades driven via reinforced styrene gear wheels in maintenance

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

SUNON SPECIFICATION FOR APPROVAL

SUNON SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X25 mm M O D E L : KDE2406PTB2 APPROVED NO : APPROVED BY : (AUTHORZIED) SPEC.NO D600732 ISSUE DATE 10.01.1998 DAWN.

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

The ventilation of the future.

The ventilation of the future. The ventilation of the future. The professionals choice EC greenvent The ventilation of the future. ge Energy, the topic for the future 2 EC-technology. A solution. 4 EC-fans. The benefit. 6 EC-centrifugal

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles Incorporating V2.3 Product spec >>> > Series ECG - Egg Crate Grilles > Series ECG45-45 Egg Crate Grilles Grilles Egg crate Recommended for: Wall, ceiling & duct Extract Overview Industry standard extract

More information

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual V - JET Counteflow System V-JET Counterflow System Installation and Operation Manual 1. System Installation By purchasing the V - JET counterflow system you have obtained high-quality product, which will

More information

Grilles & Diffusers Series LFP Incorporating

Grilles & Diffusers Series LFP Incorporating Grilles & Diffusers Incorporating Series LFP Produce a stable linear throw, creating an area of clean air with minimal diffusion Perfect for areas like clean rooms and operating theatres Tile replacer

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors ABLOY DOOR AUTOMATICS Easy access for all types of swing doors Automatic door operators bring additional convenience in situations where the doors opening manually would be inconvenient or laborious. Recommended

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Ventilation Solutions Kitchens. fantech

Ventilation Solutions Kitchens. fantech Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

TURBOWENT TULIPAN - rotary chimney cowl Ø150

TURBOWENT TULIPAN - rotary chimney cowl Ø150 Picture Function principle rotation direction Wind Chimney draught Description Rotary chimney cowl Turbowent Tulipan is a device, which, in a dynamic way, uses force of the wind to increase chimney draught.

More information

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1 Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing

More information

Operating Instructions Smoke Extract Fans (Translation of the Original) BA-SEF 2.2 06/2015 RDM 56/57 RWM 57

Operating Instructions Smoke Extract Fans (Translation of the Original) BA-SEF 2.2 06/2015 RDM 56/57 RWM 57 Operating Instructions Smoke Extract Fans (Translation of the Original) EN BA-SEF 2.2 06/2015 RDM 56/57 RWM 57 REM BU REM BI RER 13/17 SLCS AGM 01/11 AGM 02/12 RGM 91 Contents 1. Revision Index... 3 2.

More information

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD

More information

Atlas Copco Stationary air compressors

Atlas Copco Stationary air compressors Atlas Copco Stationary air compressors Oil-free and oil lubricated piston compressor 2.2 - kw / 3-7.5 hp QUALITY COMPRESSORS DESIGNED SPECIFICALLY FOR THE SNOW MAKING INDUSTRY Atlas Copco's L-range of

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) 1842 754545 Telefax +44(0) 1842 763051 e-mail trox@troxuk.co.uk www.troxuk.co.

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) 1842 754545 Telefax +44(0) 1842 763051 e-mail trox@troxuk.co.uk www.troxuk.co. 2/2./B/2 Laminar Flow Panel Type LFP TROX UK Ltd Caxton Way Thetford Norfolk IP2 3SQ Telephone +(0) 182 7555 Telefax +(0) 182 763051 e-mail trox@troxuk.co.uk www.troxuk.co.uk Contents Description Description

More information

industrial drive systems AC LINE Spring-applied single-disc brake 73 341..A00 73 431..H00 73 241..E00 / 73 245..E00

industrial drive systems AC LINE Spring-applied single-disc brake 73 341..A00 73 431..H00 73 241..E00 / 73 245..E00 industrial drive systems AC LINE Spring-applied single-disc brake 73 341..A00 73 431..H00 73 241..E00 / 73 245..E00 AC LINE Kendrion (Aerzen) GmbH, Germany Kendrion (Villingen) GmbH, Germany Kendrion Magnetic

More information

EC-fans. Energy efficient and environmentally friendly

EC-fans. Energy efficient and environmentally friendly Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans EC-fans Energy efficient and environmentally friendly 2 I EC-fans Energy efficient & environmentally

More information

We will discuss common industrial applications with guides for the proper use of electric motors on these.

We will discuss common industrial applications with guides for the proper use of electric motors on these. INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

TELESCOPE Motorized Lighting Suspension

TELESCOPE Motorized Lighting Suspension TELESCOPE Motorized Lighting Suspension Mod. 8400 FEATURES The De Sisti TELESCOPE is a single point suspension specifically designed to provide rigidity and stabilization of all moving parts. It can extend

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Operataing Manual. Single stage radial Fan. Model MKV/TKV

Operataing Manual. Single stage radial Fan. Model MKV/TKV 01.2011 Operataing Manual Single stage radial Fan Model MKV/TKV REITZ-SCHWEIZ VENTILATOR AG Zentweg 11 CH-3006 Bern Telefon +41 (0) 31 / 938 85-85 Telefax +41 (0) 31 / 938 85-86 Internet: www.reitz-schweiz.ch

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

TOP 10 NOISE CONTROL TECHNIQUES

TOP 10 NOISE CONTROL TECHNIQUES TOP 10 NOISE CONTROL TECHNIQUES The following are 10 simple noise control techniques that have wide application across the whole of industry. In many cases, they will produce substantial noise reductions

More information

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05 SIGMA PUMPY HRANICE SELF PRIMING PUMPS SVA SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +40 581 661 111, fax: +40 581 60 587 Email: sigmahra@sigmahra.cz 46.98 16.05 Applications

More information

BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 -

BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 - BAGGAGE HANDLING SYSTEMS Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 - TECHNICAL SPECIFICS INDEX Check-in with one conveyor 4 Scales 6 Belt Conveyors 8 Take away 9 Feeder and Belt

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY

Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY TYPICAL APPLICATIONS Water supply Transfer and distribution from water systems Pressure boosting in apartment buildings

More information

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity

More information

Relationship between Sound Pressure and Sound Power Levels

Relationship between Sound Pressure and Sound Power Levels Relationship between Sound Pressure and Sound Power Levels 4 W. T. W. CORY Chairman of the Eurovent WG 1 Fans If we wish to know the sound power transmitted through a fan and ducting system, it is preferable

More information

EVAC ONLINEVAC TECHNICAL DATA 6547655 EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

EVAC ONLINEVAC TECHNICAL DATA 6547655 EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13 Date: 9 Apr 202 Doc. 002967-6547655 6, 24 V DC Ø3 360 Required maintenance 990±0 960 40 040 20 890 350 (P/N 546664) 95±5 67±5 Vacuum sensor G /4 88±5 INLET DN40 943 Connection Frame: Steel S235 EN 0025

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

Air technology solutions for demanding applications. Product overview. www.elektror.com17

Air technology solutions for demanding applications. Product overview. www.elektror.com17 Air technology solutions for demanding applications Product overview www.elektror.com17 Set benchmarks now. Efficient and high-performance solutions from one source. For the past 9 years Elektror airsystems

More information

product application guide

product application guide Understanding Fan System Effects Fan Application FA/101-99 product application guide A technical bulletin for engineers, contractors and students in the air movement and control industry. The air moving

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000 Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

Laserlyte-Flex Alignment System

Laserlyte-Flex Alignment System Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning

More information

K17.12 Door closers K17. Doors 01.09.2013

K17.12 Door closers K17. Doors 01.09.2013 K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor

More information