SERIES VN HEAVY DUTY OFF-ON CAM SWITCHES
|
|
- Janis Jefferson
- 7 years ago
- Views:
Transcription
1 TO AMPS OFF-ON CAM SWITCHES OFF - ON SWITCH Open Type 5 Amp to Amp, 600 Volt 400 Amp to Amp, 690 Volt 4 Pole (0-1) 45º Switch Angle 600 Volt CSA/UL General Purpose IEC No. Chambers Catalog Number Front Base - Suffix Safety Door Interlock E VN-4B1- E VN-4B- E VN-4B- E VN50-4B4- E VN80-4B4- EVN15-4B5- E VN00-4B5- $78 $11 $167 $ $18 $781 $155 $81 $117 $17 $40 $5 $86 $194 $115 $151 $07 $00 $95 $90 $161 4 Pole (0-1) 400 Amp to Amp 690 Volt - Suffix IEC No. Chambers Catalog Number Front Base Safety Door Interlock E NL E NL60-4- E NL E NL-4-6 Pole (0-1) 45º Switch Angle 600 Volt CSA/UL General Purpose IEC No. Chambers Catalog Number Front Base - Suffix Safety Door Interlock E VN-6B1- E VN-6B- E VN-6B- E VN50-6B4- E VN80-6B4- EVN15-6B5- E VN00-6B5- $1 $155 $01 $79 $8 $886 $150 $18 $160 $1 $98 $90 $90 $158 $15 $175 $46 $58 $409 $970 $159 6 Pole (0-1) 400 Amp to Amp 690 Volt - Suffix IEC No. Chambers 6 6 Catalog Number E NL E NL60-6- E NL E NL-6- Front Base Safety Door Interlock Contact factory for pricing Ratings were requested from UL/CSA. Higher ratings are possible to match IEC ratings. Name plate is OFF-ON. Many other standard name plates are available at no extra cost. Check with factory. For 5 Amp to Amp bypass cam switches (see following pages) Discount Schedule ET 1
2 TO AMPS STEP SWITCHES (5A & 5A)* STEP SWITCH with OFF position OPEN TYPE FRONT PANEL MOUNT Typical Step Front Panel Circuit No. No. Amp* Catalog No. Steps Chambers E VN S0 B1 $ E VN S0 B1 $ E VN S04 B1 $ E VN S05 B1 $ E VN S06 B1 $ E VN S07 B1 $ E VN S08 B1 $15 Base Option* Amp* Catalog No. 5 E VN S0 B $ 5 E VN S0 B $117 5 E VN S04 B $14 5 E VN S05 B $151 5 E VN S06 B $167 5 E VN S07 B $184 5 E VN S08 B $01 Switching Angle: 45º, 8 step is 0º. Switches are available to 1 steps and to 6 Amp. Multiple pole step switches are also available. STEP SWITCH without OFF position OPEN TYPE FRONT PANEL MOUNT Typical Step Front Panel Circuit No. No. Amp* Catalog No. Steps Chambers E VN S B1 $ E VN S B1 $ E VN S4 B1 $ E VN S5 B1 $ E VN S6 B1 $ E VN S7 B1 $ E VN S8 B1 $1 ENCLOSED STEP SWITCHES Both Metal and Non Metal Enclosed Switches are available from stock. *Base (BM) Option. Substitute BS for FS in catalog number. Add $5.00 list. Base Option* Amp* Catalog No. 5 E VN S B $98 5 E VN S B $114 5 E VN S4 B $11 5 E VN S5 B $148 5 E VN S6 B $165 5 E VN S7 B $181 5 E VN S8 B $198 Stock Single Hole For catalog number - change FS above to HS Example: FVU S B-HS Add $5.00 to list price Discount Schedule ET
3 TO AMPS METER SWITCHES METER SWITCHES (Front ) See Bulletin D1 for Series D1 Meter Selections Voltmeter Switch Phase (line to line) Voltmeter Switch 1 Phase Catalog No. No. Chambers E D1-V 1FM-SO $65 E VN V 1 $7 Catalog No. No. Chambers ED 1V 1FM-SO $55 1 E VN 1V1 (5 Amp) $7 Voltmeter Switch Phase (line to line plus line to neutral) Ammeter Switch Phase ( circuits with current transformers) Catalog No. No. Chambers E D1-V 1FM-SO $108 4 E VN V 1 $84 4 Catalog No. No. Chambers E D1-1MA 1FM-SO $88 For Base, substitute BS for FS in catalog number. Same price. Ammeter Switch Phase ( circuits with or without current transformers For Single Hole, (mm (7/8 ) substitute HS for FS in catalog numbers. Add $5.00 list. To convert mm mount to Full Size, 0.5mm mount, add adapter ring: P/N# ED-145 $0.80 list Catalog No. No. Chambers E VN-MT-1FM-SI $104 5 Other Meter Switches are also available, including combination phase ammeter/voltmeter type. Discount Schedule ET
4 TO AMPS VN VN DIMENSION SERIES D1 (Enclosed Type) Enclosure Dimensions for sizes: D1, VN, VN Max Enclosure/Type B L HI A H Poles G (Metal) 6 poles max 91mm.58 97mm.8 7mm.8 4mm mm 1.0 E 79mm.11 F 8mm.7 D 5.5mm. G & GI x mm x.09 Hole Size T4 (Non-Metal) Standard Compact 6 poles max 8mm. 8mm. 67mm.6 65mm.56 4mm 1. 68mm.67 68mm mm.17 x PG16* x 0.84 Hole Size T5 (Non-Metal) Standard 8 poles max 8mm. 8mm. 9mm.66 65mm.56 4mm 1. 68mm.67 68mm mm.17 x PG16* x 0.84 Hole Size T8/1 (Non-Metal) 6 poles max 91mm.58 11mm mm.94 7mm.8 Each D1, VN, VN chamber section contains poles. 4mm 1. 76mm mm mm.17 x PG16* x 0.84 Hole Size *accepts 7/8 cord grip LEGEND PLATE TYPE SI MARKING Standard markings Identification Suffix OFF ON -N HAND OFF AUTO -K FOR OFF REV -I UP OFF DOWN -J MANUAL AUTO -L HIGH OFF LOW -P NORMAL-OFF-BYPASS -Q Check with factory for additional standard markings. Type Number of switch must be identified. (for VN Switch or for D switch) Special Marking Legend add: $6.80 PLATE S Silver with Engraved Black Letters FACE SIZE DIMENSIONS 1 7/8 x1 7/8 (48mm) 1/ x 1/ (65mm) 7/8 x 7/8 (7mm).8 x.8 (96mm) 4.9 x 4.9 (15mm) Face size 1 is standard S size on D1 and VN switches. Type S plate (silver) Face Size and 1 for VN Disconnect Inscription Plate Price MAIN SWITCH Main Switch Main Switch Fits above Type BE, BY, D, SI Operator/Plates Brush Silver with black letters Yellow with black letters Black with white letters Catalog# ED-NP- ED-NP- ED-NP- 48 x 16mm (1.9 x0.6 ) -S1 $8 -Y1 $8 -B1 $8 65 x 16mm (.5 x0.8 ) -S $9 -Y $9 -B $9 Standard marking add suffix: Main switch (-MS) or Emergency Off (-EO) For special marking add $6.80 Example: #ED-NP-S1 4 Discount Schedule ET
5 TO AMPS VN VN DIMENSION OPEN TYPE VN, VN mm inches Front Unit Insert Front View Switch Body Panel Drilling VN Front (F) Type/Type X max. Dim VN 4 L L Number of contact chambers (1.) (1.8) (.) (.7) (.) (.7) (4.1) (4.6) (5.1) (5.6) (6.0) VN Front (F) Type/Type X max. Dim VN 4 L L Number of contact chambers (1.) (1.8) (.4) (.9) (.4) (.9) (4.4) (4.9) (5.4) (5.9) (6.5) VN / VN With Safety Door Interlock (S) Number of contact chambers A H B Xmax Dim Type VN L L 1 (1.5) (1.8) (.4) (.9) (.4) (.9) (4.4) (4.9) (5.4) (5.9) (6.5) (1.9) (1.1) (1.) (1.6) T T (.9) (4.4) (4.9) (5.4) (5.8) (6.) (6.8) (7.) (7.7) (8.) (8.7) Type VN L L 1 (1.9) (1.1) (1.) (1.6) T T (1.6) (.1) (.6) (.1) (.6) (4.1) (4.6) (5.) (5.7) (6.) (6.7) (4.) (4.6) (5.1) (5.6) (6.1) (6.5) (7.0) (7.5) (7.9) (8.4) (8.9) 5
6 TO AMPS VN TO VN00 DIMENSIONS FRONT MOUNT mm inches Insert Front View Panel Drilling VN VN 50 VN 80 VN 15 VN 00 Type A H X.max Dim VN 7 4 4(.16) L (.8) (1.) VN (.16) L (.8) (1.7) VN (.16) L (.8) (1.7) VN (.16) L (4.9) (.4) VN (.16) L (4.9) (.4) 6 Number of contact chambers (1.7) 60(.4) 76(.0) 9(.6) 108(4.) 14(4.9) 140(4.9) 156(6.1) 17(6.8) 188(7.4) 04(8.0) 49(1.9) 68(.7) 86(.4) 105(4.1) 1(4.8) 14(5.6) 160(6.) 179(7.0) 197(7.8) 16(8.6) 4(9.) 57(.) 81(.) 105(4.) 19(5.1) 15(6.0) 177(7.0) 01(7.9) 5(8.9) 49(9.8) 7(10.7) 97(11.7) 77(.0) 108(4.) 19(5.5) 170(6.7) 01(7.9) (9.1) 6(10.4) 94(9.8) 5(1.8) 56(14.0) 87(15.) 77(.0) 108(4.) 19(5.5) 170(6.7) 01(7.9) (9.1) 6(10.4) 94(9.8) 5(1.8) 56(14.0) 87(15.) Request dimension sheets from factory for other styles.
7 TO AMPS TECHNICAL INFORMATION Utilization categories for alternating current switches as defined in IEC 947 (EN 60947) regulations Test Load on the Switch Current Utilization Examples of typical application Normal operation Inrush Tests category make break make break Cos AC-1 Non inductive or slightly inductive loads, resistance furnace I e I e 1.5 I e 1.5 I e 0.95 AC- Slipping motor starting without reversing, without reverse current braking I e I e 4 I e 4 I e 0.65 AC- On-Off switching of inductive loads I e I e I e I e 0.65 cos AC- Direct line starting of squirrel cage motors, switching off while running I e I e 10 I e 8 I e () AC- Switching of motors (Main Switch) I e I e 10 I e 8 I e () cos AC-4 Direct line starting of squirrel cage motors () 6 I e 6 I e 1 I e 10 I e () AC-15 Control switching for switching magnetics devices contactors, valves, pull-type magnets 10 I e I e 10 I e 10 I e 0. I e = Rated operating current () Inching (jogging) or energizing a motor for short periods of time to obtain small increments of movement. Plugging-stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. () I e A cos 0.45; I e A cos 0.5 CATALOG NUMBER CODE VN SERIES EXAMPLE: E VN - B F - R An Elektra Product Type and Size Switch pole ON-OFF Type Circuit Example: W is reversing Type Operator: Handle B Black Knob R-Red Operator Handle D-Black D Handle S-Silver Black NP with B Knob S-Safety Door Interlock F - Front B - Base H - Single Hole Name Plate Face Size Size 1 to 5 7
8 TO AMPS SERIES VN TECHNICAL INFORMATION UL/CSA Rating Switch Size VN VN VN VN50 VN80 VN15 VN00 Canada/USA V General Use 600V ac max. A phase 40 V hp Motor phase 480 V hp V hp Single phase 10 V hp V hp Note: Above UL/CSA ratings are as submitted to UL. (1) only CSA tested International Rating Switch Size VN VN VN VN50 VN80 VN15 VN00 Rated insulating voltage IEC 947 (111/) v Rated Impulse voltage IEC 947 (111/) KV Thermal rated current open with max. wire cross section (without connections) I th A Connectable cross sections single resp. multi-strand mm (1) 5-10 (1) Fine wire with core end bush (DIN 46 8) mm Terminal Screws M4 M4 M5 M5 xm4 M8 M10 Short-circuit protection, fusable cut out gl or am A max Properties of main switches Requirements for isolators compiled with up to v Clear indication of switching position Switching capacity under alternating voltage conditions AC-1 Load break switches Rated operating current I e A Rated operating voltage U e v AC V, kw Motor switches (main switches) V, kw V, kw V (), kw AC V, kw Motor switches for operational switching V, kw V, kw V (), kw AC V, kw Motor switches inching counter current breaking V, kw V, kw V (), kw AC-15 Control switches Ie at 0-40/80-440/500V A 6/4/- 9/6/- 16/8/ (1) with DIN cable lug () Rated mains voltage DIN IEC 8 8
9 SERIES D1 DISCONNECT SWITCHES 5 Amp / 600 VOLT also 16 Amp 600 VOLT SERIES D1 MULTI- APPLICATION SWITCHES Machine Disconnect Motor Switch Bypass Switch Step Switch Reversing Switch Two Speed Switch Ammeter Switch Voltmeter Switch To 8 Pole, 8 Positions ELEKTRA DISCONNECTS MACHINE SAFETY DISCONNECT OPTION FEATURING HANDLE-SHAFT SELF-ALIGNING SYSTEM IP65 DUSTTIGHT / WATERTIGHT METAL / NON-METAL ENCLOSURES STEEL SHAFT HORSEPOWER RATED ELECTRICAL & ELECTRONIC CONTROLS, INC. 881 DANBRY Rd. Brewster, NY (845) FAX (845) info@eecontrols.com EECONTROLS, LTD 17 STEWART COURT ORANGEVILLE, ONTARIO CANADA L9W Z FAX
10 DISCONNECTS 5 AMP SERIES D1 SWITCHES (INDEX) THE MULTI APPLICATION SWITCH! SERIES D1 DISCONNECTS (ON-OFF) 5 Amp 600 VOLT PADLOCKABLE Lockout Tagout Page SAFETY DOOR INTERLOCKS Auto Alignment Page Direct Drives Page Front Disconnects Enclosed Dust / Water Tight Page 5 Base Page Page SERIES D1 SWITCHES Reversing Switch Page 4 Non-Auto Alignment STEP SWITCH Page 5 Fusible Open BYPASS Page 6 Fusible Enclosed Page METER Page 07 Special Switches Page7 Also Available: Disconnects Series D through 7 to 50 Amp Series D8, 9 to 60 Amp SPRING RETURN Page 7 KEY OPERATED Page 4 CAM SWITCHES to 60 AMP UP TO 1 POLES, 1 POSITIONS 0 UV TRIP Series F and S with UV Trip (Under Voltage Trip) BUILT TO CUSTOMER SPECS See page 09 Electrical and Electronic Controls Inc. 881 Danbury Rd. Brewster, NY (845) FAX (845) address: info@eecontrols.com In Canada EE Controls, Ltd. 17 Stewart Court Orangeville, Ontario, Canada L9WZ9 (519) FAX (519)
Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationREVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
More informationCam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5
Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More information3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A
Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationTransformers from 25va to 500kva. Standard despatch in days not weeks
Transformers from 25va to 500kva Standard despatch in days not weeks JMS Transformers Ltd 20 Ivatt Way Westwood Business Park Peterborough PE3 7PG UK Tel: +44 (0)1733 760000 Fax +44 (0)1733 760004 e-mail:
More informationHS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.
y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock
More informationTP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12
Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator
More informationEDS / EFS Series Control Stations
EDS / EFS Series Fully Assembled EFS and EDS Factory Sealed Devices NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More informationGeneral Informations 2 Technical data 3 Basic designs 4-8
Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23
More informationSBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Applications
SBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Compact design Up to 10 stages (20 contacts) Double surface cams (one
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationThe Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:
The Charging System Charging System The charging system has two essential functions: Generate electrical power to run the vehicle s electrical systems Generate current to recharge the vehicle s battery
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationEDS / EFS Series Control Stations
EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures
More informationCam Switches, Manual Motor Controllers, Disconnects For Single phase Applications
7/ Moeller Electric Corporation Manual Motor Controllers, Disconnects For use as Padlockable, red handle with yellow collar, suitable as Emergency-Stop Circuit function diagram Front Plate No. ) ON OFF
More informationIEC 309 INTERLOCKS NORTH AMERICAN
IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing
More informationpicomax The Pluggable Connection System
picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable
More informationETZGAR CONVEYOR COMPANY Controls Section v12.05
Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationATS - Automatic Changeover
ATS - Automatic Changeover Manufacturers of Electrical Switchgear Choosing an Automatic Transfer System Switchgear Systems offer a variety of solutions for multiple supply switching needs. As well as our
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More informationDistribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationTHE ADVANTAGES ARE YOURS
THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationSafety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More informationMCC Ratings. Voltage Rating
MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control
More informationBreakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM
Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationTECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting
Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationSICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A
s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationZ-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com
CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationPlugs and Receptacles
Plugs and Receptacles Industrial Heavy Duty Interlocked Application and Selection Applications: Where extra protection is a requirement; interlocked units provide dead front receptacles; connection cannot
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationPendant control stations 6
Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications
More informationSPEEDFAX TM 2011 Disconnect Switches Contents
SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection
More informationManual Switches Series 2 Pushbutton Switches and Indicators
BARRIER MOUNT Display screen (page 115) Mounting barrier (next page) Housing (next page) FEATURES Easy-to-assemble modules provide thousands of display/control combinations Up to 4 incandescent lamps 1,
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationLow Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper
Low Voltage Disconnect Switches NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper Scope This document is intended to discuss the functional requirements for the disconnecting
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationClass 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015
Hubbell Industrial Controls, Inc. Class 58 Drum Controller Catalog & Price List November 205, Replaces Jan 205 Class 58 Drum Controllers start, stop and change the speed and/or rotating direction of reversible
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fire pumps
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationSECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationDIRECT CURRENT GENERATORS
DIRECT CURRENT GENERATORS Revision 12:50 14 Nov 05 INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy by using the principle of magnetic induction. This principle
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationHow To Build A Germany Power Plant
Medium Voltage Air Insulated Motor Control Featuring AdvanceTM Technology. Medium Voltage Motor Control Center Product Description Contemporary Design Advance TM medium voltage motor control center (MVMCC)
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationGE Power Controls. MiniFORM Switchboards
GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationVLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
More informationMolded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More informationW DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6
W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER 25-100A, SERIES BCF0 AND BCF6 W SCHRACK-INFO Any mains connection If using 4-pole. switches with 3 or 2-poles, ensure connection acc. to assembly instructions
More informationThe Ultimate Truck Stock Motor
The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationTrade of Electrician. Three-phase Distribution Boards And Socket Circuits
Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision
More informationWe will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More information